1. in the U S and other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc The OPEN LOOK and Sun Graphical User Interface was developed by Sun Microsystems Inc for its users and licensees Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry Sun holds a non exclusive license from Xerox to the Xerox Graphical User Interface which license also covers Sun s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun s written license agreements RESTRICTED RIGHTS Use duplication or disclosure by the U S Government is subject to restrictions of FAR 52 227 14 g 2 6 87 and FAR 52 227 19 6 87 or DFAR 252 227 7015 b 6 95 and DFAR 227 7202 3 a DOCUMENTATION IS PROVIDED AS IS AND ALL EXPRESS OR IMPLIED CONDITIONS REPRESENTATIONS AND WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT ARE DISCLAIMED EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID Copyright 2000 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreignent l utilisation la copie la distribution et la d compilation Aucune partie de ce produit ou docum
2. Enterprise 450 Server Board Upgrade Guide used with the Ultra Enterprise 450 Server Owner s Guide gives you the information you need to perform a main logic board upgrade to your Sun Enterprise 450 server Features and options installation troubleshooting parts replacement network administration information and other topics about the Sun Enterprise 450 server are all covered in the Ultra Enterprise 450 Server Owner s Guide which accompanied your purchase of the server Refer to the original documentation to install the parts you will be transferring from your old server into your new Sun Enterprise 450 server You should also use the documentation to install any options that you purchased with this upgrade In addition you can view many of the component installation and replacement procedures in the multimedia CD ROM application ShowMe How which also accompanied your purchase of the original server Using UNIX Commands This document may not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and configuring devices See one or more of the following for this information Solaris Handbook for Sun Peripherals AnswerBook2 online documentation for the Solaris operating environment Other software documentation that you received with your system vii Typographic Conventions Typeface AaBbCc123 AaBbCc123 AaBbCc123 Meaning
3. The names of commands files and directories on screen computer output What you type when contrasted with on screen computer output Book titles new words or terms words to be emphasized Command line variable replace with a real name or value Shell Prompts Shell C shell C shell superuser Bourne shell and Korn shell Bourne shell and Korn shell superuser viii Sun Enterprise 450 Server Board Upgrade Guide August 2000 Examples Edit your login file Use 1s a to list all files 2 You have mail su Password Read Chapter 6 in the User s Guide These are called class options You must be superuser to do this To delete a file type rm filename Prompt machine_name machine_name Related Documentation Application Title Performing diagnostic tests SunVTS User s Guide SunVTS Quick Reference Card SunVTS Test Reference Manual Solstice SYMON User s Guide System and network administration Solaris System Administrator Answer Book SPARC Installing Solaris Software Using operating system software Solaris User s Guide Miscellaneous Solaris on Sun Hardware AnswerBook Solaris Handbook for Sun Peripherals SPARC Hardware Platform Guide Accessing Sun Documentation Online The docs sun com web site enables you to access Sun technical documentation on the Web You can browse the docs sun com archive or search for a specific book
4. have ordered one or more of the following hardware components Memory modules 32 megabyte or larger capacity SIMMs CPU module Additional DC to DC converter s if necessary New disk drives If any item except CPU modules is not included in the list above you are expected to transfer the item s from your old system main logic board to your new one When you upgrade to a Sun Enterprise 450 server you must return your old main logic board to Sun Microsystems See Return Material Procedure on page 16 for additional details Unpacking the Shipping Cartons Follow these steps to unpack your main logic board 1 Inspect the shipping cartons before opening them If there is evidence of damage to a carton contact your sales representative and arrange for an agent of the carrier to be present when you remove the equipment 2 Sun Enterprise 450 Server Board Upgrade Guide August 2000 2 Unpack your new Sun Enterprise 450 server main logic board and the CPU air guide 3 Save the cartons and the packing material You will need them to return your old main logic board Transferring Your System s hostid and Ethernet Address Because the new NVRAM module on the replacement board contains a new hostid and a new Ethernet address unless you transfer the NVRAM module from your old main logic board to your replacement board your server s Ethernet address and hostid number will change This information
5. not the Class B requirements Please read the sections that apply to Class A products in the Regulatory Compliance Statements in the Ultra Enterprise 450 Server Owner s Guide Note To be compliant with international EMC regulations the upgrade label provided must be correctly applied to the upgraded system 14 Sun Enterprise 450 Server Board Upgrade Guide August 2000 Read and follow the directions in the next section Applying a Class A Label Locate the Class B label on the rear panel of the Sun Enterprise 450 server The label is located at the top of the back panel in the middle just above the AC line filter Peel off the new Class A label from its backing material With the sticky side down align the left edge of the new label with the left edge of the existing large label Position the new label 50 that it covers all of the old label except the right side panel containing Electrical Ratings and Product Safety marks and on older labels the country of origin in the bottom left corner Press the label firmly into place Sun Enterprise 450 Server Board Upgrade Guide 15 Powering Up Your Upgraded System The procedure for powering up your system depends on a number of factors including the operating system you are using your network environment and your server s hostid and Ethernet address The network environment may require some advance preparation before you turn on your se
6. this guide and verify that the jumper settings are correct for the speed of the CPU module s you are installing Serious system damage can result if the main logic board clock mode jumpers are set incorrectly If you need to know your system s power consumption read the section Calculating System Power Requirements on page 8 in this guide and then consult the section How to Determine System Power Requirements in the Ultra Enterprise 450 Server Owner s Guide The 480 MHz CPU modules require an air guide for proper cooling This air guide is shipped with the 501 5673 main logic board To install CPU modules into the Sun Enterprise 450 server follow the instructions in the section How to Install a CPU Module in the Ultra Enterprise 450 Server Owner s Guide In addition read the installation notes that shipped with the CPU modules Sun Enterprise 450 Server Board Upgrade Guide 7 Before installing the CPU module verify that each new module is one of the following UltraSPARC II modules for Sun Enterprise 450 servers The following table identifies CPU module speeds CPU Module Speed MHz Part Number 250 MHz UltraSPARC II 501 4857 or 501 4278 300 MHz UltraSPARC II 501 4849 or 501 4196 400 MHz UltraSPARC II 501 5239 or 501 5446 480 MHz UltraSPARC II 501 5729 Before you install the fourth CPU module into the top CPU slot CPU A1 remove the blank baffle if installed from the connector J0101 Grasp
7. title or subject at http docs sun com Ordering Sun Documentation Fatbrain com an Internet professional bookstore stocks select product documentation from Sun Microsystems Inc Preface ix For a list of documents and how to order them visit the Sun Documentation Center on Fatbrain com at http wwwl fatbrain com documentation sun Sun Welcomes Your Comments Sun is interested in improving its documentation and welcomes your comments and suggestions You can email your comments to Sun at docfeedback sun com Please include the part number 806 4667 10 of your document in the subject line of your email x Sun Enterprise 450 Server Board Upgrade Guide August 2000 Sun Enterprise 450 Server Board Upgrade Guide This document and the Ultra Enterprise 450 Server Owner s Guide contain the information you need to upgrade the main logic board in your Sun Enterprise 450 server and to install faster CPU modules For important safety and electromagnetic compatibility information read the section Electromagnetic Compatibility on page 14 in this document Overview The following sections of this document provide background information and cover the main steps involved in the upgrade procedure Confirming the Upgrade Contents on page 2 Unpacking the Shipping Cartons on page 2 Transferring Your System s hostid and Ethernet Address on page 3 Halting Your System on page 4 Rem
8. Main Logic Board Components is higher than 5402833 04 read the following paragraphs and then skip forward to the section Powering Up Your Upgraded System on page 16 The Sun Enterprise 450 server meets the Class B requirements for electromagnetic interference EMI conforming to international standards Some of these standards are noted in the Declaration of Conformity in the Regulatory Compliance Statements in the Ultra Enterprise 450 Server Owner s Guide The Class B requirements are intended for home use and are more stringent than Class A requirements The Class B limits are designed to provide reasonable protection in the home against radio frequency interference Caution Connecting headphones to the headphone jack of the Sun Enterprise 450 server CD ROM drive can result in radio frequency emissions that exceed Class B limits Please read the sections that apply to Class A equipment in the Regulatory Compliance Statements at the beginning of the Ultra Enterprise 450 Server Owner s Guide There are several measures you can take to correct interference problems For additional correction details see the FCC Class B Notice in the Regulatory Compliance Statements Class A EMC Label Any Sun Enterprise 450 server configured with a chassis numbered 5402833 04 or lower with an upgraded main logic board and with new 480 MHz 8 Mbyte UltraSPARC II CPU modules meets the Class A system requirements for EMI but
9. application software Sun Enterprise 450 Server Board Upgrade Guide 3 Note Before performing the main logic board upgrade you must save any customized NVRAM information separately such as an nvramrc script or any other non default settings so that you may restore the information later If you do not transfer your NVRAM module the system administrator will need to know the new Ethernet address and hostid stored in the new NVRAM module 4 Halting Your System Caution You must halt the system in an orderly manner When the operating system or any other standalone program is up and running do not press Stop A to halt the system Abruptly aborting program execution may cause damage to data files Halt your system using the following procedure 1 Save all your work Consult your software documentation for instructions on ending a work session and saving your files If you do not save your work you could lose it when you switch off the power 2 Perform a complete system dump before starting the upgrade process See your operating system documentation if you need instructions on how to do this 3 Return to the operating system environment If you are in a windowing environment exit from it and wait for the system prompt to appear See the documentation supplied with your windowing system Caution If you are transferring your NVRAM module and have customized your NVRAM module with an nvramrc script together with an
10. ceived including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio television technician for help Shielded Cables Connections between the workstation and peripherals must be made using shielded cables in order to maintain compliance with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are n
11. d system board when you return it to Sun Microsystems 3 Install the old NVRAM module on the new main logic board using the steps in the section How to Install the NVRAM module in the Ultra Enterprise 450 Server Owner s Guide Then perform the remaining steps below Note If you have customized your NVRAM module with an nvramrc script together with any non default settings in the NVRAM you will need to restore the information separately after you have performed the upgrade 4 Reconnect the main logic board to its power connector Push on the handles at the rear of the board until the board is fully engaged in its power connector Tighten the captive screws that secure the board to the system rear panel 5 Follow the remaining steps in the section How to Install the Main Logic Board in the Ultra Enterprise 450 Server Owner s Guide 6 Sun Enterprise 450 Server Board Upgrade Guide August 2000 Installing UltraSPARC II CPU Modules The Sun Enterprise 450 server supports up to four 250 MHz 300 MHz 400 MHz or 480 MHz UltraSPARC II CPU modules The following figure shows the new unshrouded 480 MHz UltraSPARC II CPU module that has 8 Mbytes of integrated cache memory Before installing CPU modules read the section About CPU Modules in the Ultra Enterprise 450 Server Owner s Guide Caution Before you install any CPU module read the section Setting the Main Logic Board Jumpers on page 9 in
12. device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded Cables Connections between the workstation and peripherals must be made using shielded cables to comply with FCC radio frequency emission limits Networking connections can be made using unshielded twisted pair UTP cables Modifications Any modifications made to this device that are not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment FCC Class B Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference re
13. e is essential for proper CPU cooling and you must install it in the reassembled system When you unpack the new main logic board set the CPU air guide aside in a safe place for later installation Sun Enterprise 450 Server Board Upgrade Guide 5 If you are using the new NVRAM perform the steps in the section How to Install the Main Logic Board in the Ultra Enterprise 450 Server Owner s Guide and then go to the section Confirming the Upgrade Contents on page 2 If you are transferring the old NVRAM module perform the first three steps in the section How to Install the Main Logic Board in the Ultra Enterprise 450 Server Owner s Guide Then perform the following steps 1 Disconnect the main logic board from its power connector Loosen the captive screws that secure the board to the system rear panel and pull the handles at the rear of the board until the board is fully disengaged from its power connector Caution Failure to do so could corrupt the information stored in the NVRAM module and adversely affect operation of the system 2 Transfer the NVRAM module from the old main logic board to the new main logic board Remove the new NVRAM module from the new main logic board using the steps in the section How to Remove the NVRAM module in the Ultra Enterprise 450 Server Owner s Guide Be sure to keep the old and the new NVRAM modules clearly identified You will need to install the new module into the ol
14. echerche et le d veloppement du concept des interfaces d utilisation visuelle ou graphique pour l industrie de l informatique Sun d tient une licence non exclusive de Xerox sur l interface d utilisation graphique Xerox cette licence couvrant galement les licenci s de Sun qui mettent en place l interface d utilisation graphique OPEN LOOK et qui en outre se conforment aux licences crites de Sun CETTE PUBLICATION EST FOURNIE EN L ETAT ET AUCUNE GARANTIE EXPRESSE OU IMPLICITE N EST ACCORDEE Y COMPRIS DES GARANTIES CONCERNANT LA VALEUR MARCHANDE L APTITUDE DE LA PUBLICATION A REPONDRE A UNE UTILISATION PARTICULIERE OU LE FAIT QU ELLE NE SOIT PAS CONTREFAISANTE DE PRODUIT DE TIERS CE DENI DE GARANTIE NE S APPLIQUERAIT PAS DANS LA MESURE OU IL SERAIT TENU JURIDIQUEMENT NUL ET NON AVENU GS tem Ca Adobe PostScript Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class e Federal Communications Commission FCC USA e Industry Canada Equipment Standard for Digital Equipment ICES 003 Canada e Voluntary Control Council for Interference VCCI Japan e Bureau of Standards Metrology and Inspection BSMI Taiwan Please read the appropriate section that corresponds to the marking on your Sun product before attempting to install the product FCC Class A Notice This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This
15. el the air guide against the Y bracket on the main logic board and snap the August 2000 Sun Enterprise 450 Server Board Upgrade Guide 12 4 Remove the right side panel using the steps in the section How to Remove the Right Side Panel Examine the chassis bar code label on the top of the system see figure below On the bottom line is a number Write down the number If your number is the same or lower than 5402833 04 you must apply a Class A EMC label to your Sun Enterprise 450 server Chassis bar code label 5 Install the right side panel using the steps in the section How to Install the Right Side Panel 6 Install the left side panel using the steps in the section How to Install the Left Side Panel 7 Reconnect any external cables to the rear panel of the main logic board see the section Locating Rear Panel Features Sun Enterprise 450 Server Board Upgrade Guide 3 Electromagnetic Compatibility If the number you recorded in Step 4 in the section Installing the Remaining Main Logic Board Components on page 10 is the same or lower than 5402833 04 you must read the section Class A EMC Label below and apply the new Class A EMC label If the chassis number you recorded in Step 4 in the section Installing the Remaining
16. ent ne peut tre reproduite sous aucune forme par quelque moyen que ce soit sans l autorisation pr alable et crite de Sun et de ses bailleurs de licence s il y en a Le logiciel d tenu par des tiers et qui comprend la technologie relative aux polices de caract res est prot g par un copyright et licenci par des fournisseurs de Sun Des parties de ce produit pourront tre d riv es des syst mes Berkeley BSD licenci s par l Universit de Californie UNIX est une marque d pos e aux Etats Unis et dans d autres pays et licenci e exclusivement par X Open Company Ltd La notice suivante est applicable Netscape Communicator M Copyright 1995 Netscape Communications Corporation Tous droits r serv s Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Sun Enterprise SunCD ShowMe How et Solaris sont des marques de fabrique ou des marques d pos es ou marques de service de Sun Microsystems Inc aux Etats Unis et dans d autres pays Toutes les marques SPARC sont utilis es sous licence et sont des marques de fabrique ou des marques d pos es de SPARC International Inc aux Etats Unis et dans d autres pays Les produits portant les marques SPARC sont bas s sur une architecture d velopp e par Sun Microsystems Inc L interface d utilisation graphique OPEN LOOK et Sun a t d velopp e par Sun Microsystems Inc pour ses utilisateurs et licenci s Sun reconna t les efforts de pionniers de Xerox pour la r
17. is used by the system administrator to identify your server in the network configuration files and the information is also often used for licensing application software Locate the NVRAM module on the main logic board If necessary see the section How to Remove the NVRAM Module in the Ultra Enterprise 450 Server Owner s Guide The system s new Ethernet address is on the label on the new NVRAM module The label contains part of the system s Ethernet address a six digit hexadecimal number For example the NVRAM label numbers might read 79F843 These numbers comprise the last three pairs of numbers in the system s Ethernet address The system s Ethernet address is the label number with a prefix of the numbers 080020 Thus the system s new Ethernet address in this example would be 08 00 20 79 F8 43 The system s new hostid is on the label on the new NVRAM module The label contains part of the system s hostid a six digit hexadecimal number For example the NVRAM label numbers might read 79F843 The system s hostid is the hexadecimal number with a prefix of the number 80 Thus the system s new hostid in this example would be 8079F843 Note The system s Ethernet address and hostid are also displayed on the system banner when you power up If you transfer the NVRAM chip from your old main logic board to the new main logic board you do not have to make any changes to your server configuration files or to your
18. ith 7 5 8 MB Ecache and DC to DC converter 400 MHz CPU with 5 0 4 MB Ecache and DC to DC converter Internal Storage Device Options SunCD 32 CD ROM DVD ROM 18 GB hard disk drive 36 GB hard disk drive DDS4 tape drive Setting the Main Logic Board Jumpers The following information supersedes the information presented in the section About the Clock Mode Select Jumper in the Ultra Enterprise 450 Server Owner s Guide Contrary to the table in that section the new Sun Enterprise 450 server main logic board 501 5673 uses the clock mode select jumpers J2701 and J2702 Set the clock mode jumper shunts at addresses J2701 and J2702 to correspond to the speed of your UltraSPARC II CPU module Verify that the jumper setting is correct before starting the system Clock Speed J2701 J2702 250 MHz 1 2 2 3 300 MHz 1 2 2 3 400 MHz 2 3 2 3 480 MHz 2 3 1 2 Sun Enterprise 450 Server Board Upgrade Guide 9 Installing the Remaining Main Logic Board Components Refer to the following sections in the Ultra Enterprise 450 Server Owner s Guide to restore the remaining main logic board components you removed from the old main logic board Install any PCI cards by following the steps in the section How to Install a PCI Card Install any DC to DC converter using the steps in the section How to Install a DC to DC Converter Install any memory
19. module by following the steps in the section How to Install a Memory Module Note If you purchased new memory modules be sure to consult the configuration rules in the section About Memory in the Ultra Enterprise 450 Server Owner s Guide 10 Reassembling Your System To reassemble the system complete the following steps Refer to the sections in the Ultra Enterprise 450 Server Owner s Guide unless otherwise noted Install the CPU fan tray using the steps in the section How to Install the CPU Fan Tray Assembly Reconnect any other devices that you disassembled from the main logic board to perform the upgrade Consult the documentation that accompanied these devices for details about installing and configuring them Sun Enterprise 450 Server Board Upgrade Guide August 2000 3 Install the CPU air guide a Hook the air guide tabs under the slots in the CPU fan tray assembly The air guide must be held at an angle to provide enough clearance to hook the tabs under the slots in the CPU fan tray assembly Pil PLO f AT b Slide the air guide toward the rear of the chassis to secure the air guide tabs to the CPU fan tray assembly Sun Enterprise 450 Server Board Upgrade Guide 1 Lun Y latch closed c Swiv
20. odules that you have purchased but did not transfer to the new main logic board To return your old equipment to Sun Microsystems 1 Disconnect any cables that may still be attached to the system unit 2 Pack the components in appropriate packing materials Use the main logic board s Sun Enterprise 450 server upgrade packing materials if possible Be sure that the components are secure and well padded inside their respective shipping cartons 16 Sun Enterprise 450 Server Board Upgrade Guide August 2000 3 Follow the instructions in the Sun Upgrades RMA Letter to return the equipment to Sun Microsystems You have completed the upgrade process If you encounter any difficulties with your new server call the Sun Response Center or your authorized service provider Sun Enterprise 450 Server Board Upgrade Guide 7 18 Sun Enterprise 450 Server Board Upgrade Guide August 2000
21. ot approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment ICES 003 Class A Notice Avis NMB 003 Classe A This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada ICES 003 Class B Notice Avis NMB 003 Classe B This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada VCCI 5 iv HEIDIT 222 VCCI DT 2 EME 7 3 04 2 7 0610168 252 CEDEX 60 DREUX tea ESS VCCI OEE ARR RE CT COR CARRERE CET 5 CRE 25 SCF EAN HOEFT COBAIN AAG DTM R Sik TS SKID BORAENSTEMBVET DIABVCC DT 2500 ORR WH 2527 Zya BLUTTY ZBRET LET TUL TEP OLS BE A ERRA VCCI OREHE TDA een RE Co CORBI AER CHATSCEZANWELTIETA ACTV EV CEA ANS 5 VaR eS Si CTTEMHBOKT 131206 0050 y Sun Enterprise 450 Server Board Upgrade Guide August 2000 BSMI Class A Notice The following statement is applicable to products shipped to Ta wan and marked as Class A on the product compliance label RARE ERPENENER RENREH E PAS 8 0 Regulatory Compliance Statements v vi Sun Enterprise 450 Server Board Upgrade Guide August 2000 Preface The Sun
22. oving the Old Main Logic Board on page 5 Installing the New Main Logic Board on page 5 Installing UltraSPARC II CPU Modules on page 7 Installing the Remaining Main Logic Board Components on page 10 Reassembling Your System on page 10 Electromagnetic Compatibility on page 14 Powering Up Your Upgraded System on page 16 Return Material Procedure on page 16 For the procedures that follow use the sections in the Ultra Enterprise 450 Server Owner s Guide where noted Be sure to read all the information that precedes the steps and follow any procedures noted there in the Ultra Enterprise 450 Server Owner s Guide You should also have on hand the documentation supplied with any third party devices that you installed on your server s main logic board You will need to refer to that documentation to perform some of the procedures during this upgrade Be sure to read each section that follows in its entirety as well as any necessary information in the Ultra Enterprise 450 Server Owner s Guide to upgrade the main logic board Confirming the Upgrade Contents Your Sun Enterprise 450 server main logic board upgrade kit includes the following Sun Enterprise 450 server main logic board CPU air guide Class A Electromagnetic Compatibility EMC label Wrist strap Antistatic mat Sun Upgrade Program Policy document Sun Upgrades RMA letter In addition to the main logic board upgrade you may
23. rver and connect it to the network Refer to the Ultra Enterprise 450 Server Owner s Guide for instructions about configuring your server before powering up The amount of preparation required will also depend on whether you transferred your old NVRAM module to the new main logic board The system administrator uses network information to identify your server in the network configuration files and to configure application software licenses If you did not transfer your old NVRAM module you or your administrator will need to update certain network configuration files before the upgraded system can join the network Be sure to inform your system administrator of the new hostid and the new Ethernet address and to register any software licenses that use your system s new hostid number Do not power up your system until you have notified your system administrator of your configuration changes and have received permission to proceed If you must act as your own system administrator see the documentation that accompanies your operating system software Return Material Procedure With your upgrade you ordered a Return Material Authorization RMA documentation set that includes a letter and instructions for returning your old equipment to Sun Microsystems Once you have completed the upgrade process you must return your old main logic board to Sun Microsystems Before returning your old main logic board be sure to remove and keep any memory m
24. sS amp Sun microsystems Sun Enterprise 450 Server Board Upgrade Guide Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 U S A 650 960 1300 Part No 806 4667 10 August 2000 Revision A Send comments about this document to docfeedback sun com Copyright 2000 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 USA All rights reserved This product or document is protected by copyright and distributed under licenses restricting its use copying distribution and decompilation No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors if any Third party software including font technology is copyrighted and licensed from Sun suppliers Parts of the product may be derived from Berkeley BSD systems licensed from the University of California UNIX is a registered trademark in the U S and other countries exclusively licensed through X Open Company Ltd For Netscape Communicator the following notice applies Copyright 1995 Netscape Communications Corporation All rights reserved Sun Sun Microsystems the Sun logo AnswerBook2 docs sun com Sun Enterprise SunCD ShowMe How and Solaris are trademarks registered trademarks or service marks of Sun Microsystems Inc in the U S and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc
25. the blank baffle by the front handle and pull it out from the CPU slot Configuring the CPU Modules Before configuring the CPU module s determine if your system will support the power requirements of the new configuration Review Calculating System Power Requirements on page 8 of this guide and see the section How to Determine System Power Requirements in the Ultra Enterprise 450 Server Owner s Guide In addition read the installation notes that shipped with the CPU modules i Caution All CPU modules installed in 8 system must operate at identical clock speeds Configure the UltraSPARC II CPU modules in your server according to the rules in the section About CPU Modules in the Ultra Enterprise 450 Server Owner s Guide and in Setting the Main Logic Board Jumpers on page 9 of this guide Calculating System Power Requirements The following information is an addition to the section System Power Requirements Worksheet in the Ultra Enterprise 450 Server Owner s Guide Use the following table for your power requirement calculations if you are installing any of the following components 480 MHz CPU module with 8 Mbyte Ecache 400 MHz CPU module with 4 Mbyte Ecache SunCD 32 CD ROM DVD ROM 8 Sun Enterprise 450 Server Board Upgrade Guide August 2000 No 18 Gbyte hard disk drive 36 Gbyte hard disk drive DDS4 tape drive Option Qty Amps CPU Options 480 MHz CPU w
26. y non default settings in the NVRAM you will need to save the information separately now so that you may restore the information after you have performed the upgrade 4 Halt the operating system See the documentation supplied with your operating system for instructions on how to halt it Sun Enterprise 450 Server Board Upgrade Guide August 2000 For Solaris 2 5 1 Hardware 11 97 or later compatible systems type oe su Password superuser password usr sbin shutdown y g60 i0 The operating system warns other users of your system of the impending shutdown and then halts itself after a one minute delay If you wish to provide a longer delay see the man page for shutdown 1 The system responds with system halt messages followed by either the gt prompt or the ok prompt When either prompt appears you can safely turn off the power in the proper sequence 5 Turn off the power in sequence to a External drive units if any b Sun Enterprise 450 server unit c Monitor if applicable Removing the Old Main Logic Board Remove the old main logic board using the steps in the section How to Remove the Main Logic Board in the Ultra Enterprise 450 Server Owner s Guide Remove and clearly label the old NVRAM module if you plan to transfer it to the new main logic board Installing the New Main Logic Board Note The 501 5673 main logic board comes with a CPU air guide This CPU air guid