image

Contents

1. 2009 Sony Professional Solutions Europe UK Jays Close Basingstoke Hampshire RG22 4SB Telephone 01256 355011 Fax 01256 474585 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 Section Models Software Upgrade Method 15 3 Firmware Package USB cable 15 4 PDW Terminal Service Tool PC software 16 1 PDW V1 Package Ethernet 20 1 PMW EX1 EX3 EX30 Binary Package Loader PC software 20 2 Binary Package USB cable SxS PRO Device Driver XDCAM EX Clip Browser PC software Mac software 2 PDBK 101 NETWORK BOARD 2 1 Applicable Models The PDBK 101 Network Board can be installed in the following models PDW 70MD PDW 75MD PDW F30 PDW F70 PDW F75 2 2 NET Software Caution Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 1 Upgrade the software as described in Section 3 3 Maintenance Menu of the respective Service Manual PDW F30 F70 70MD Service Manual Volume 1 Edition 1 Revision 2 part number 9 968 227 03 PDW F75 75MD Service Manual Volume 1 Editio
2. SONE ENGINEERING BULLETIN Sony Professional Solutions Europe E PDW 001 5 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM 27 02 2009 Product PDBK 101 PDBK 102 PDBZ E1500 PDW 1500 PDW 510 PDW 510P PDW 530 PDW 530P PDW 700 PDW 70MD PDW 75MD PDW D1 PDW F30 PDW F330 PDW F335 PDW F350 PDW F355 PDW F70 PDW F75 PDW HD1500 PDW R1 PDW U1 PDW V1 PDZ 1 PDZK P1 PDZ VX10 PMW EX1 PMW EX3 PMW EX30 XDZ P1 Serial No All 1 DESCRIPTION This document describes how to upgrade the software for the XDCAM range of products Caution For full compatibility always ensure that the latest software versions are installed These procedures should only be performed by a qualified service engineer Table 1 Summary Section Models Description of Software Upgrade Method 2 2 PDBK 101 NET Ethernet Package TSI 54 board PDW 1500 6 1 PDW 510 510P 530 530P BOOT Program V1 10 6 2 AT MAIN program Memory stick 6 3 Package Memory stick from V1 450 and higher Ethernet via CBK NC01 Adapter PDW 700 Package PDW F330 F350 A eee PDW HD1500 Package 1 of 21 43751 This bulletin is published by the Online Marketing department of Sony Professional Solutions Europe as an aid to the servicing alignment or modification of Sony equipment and is to be used at the user s discretion Sony assumes no obligation hereby as to the supply of parts payment for modifications replacement of units or otherwise
3. FAM Driver is installed 1 Decompress the ZIP file to a temporary folder on the PC 2 Install the software as described in Section 4 2 Activating MAINTENANCE MENU of the PDW U1 Maintenance Manual Volume 1 Edition 1 Revision 2 part number 9 968 377 03 Note This software is supplied as a ZIP file not an LZH file as stated in the Service Manual 16 PDW V1 16 1 Package Software This procedure can only be used to upgrade from Package V1 180 or higher If an earlier version is installed contact your local Sony Service Centre Caution Note Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac Verify software package V1 180 or higher is installed in the STATUS gt SOFTWARE VERSION screen of the XDCAM web site or from the MAINTENANCE gt OTHERS gt SOFTWARE VERSION menu If an earlier version is installed contact your local Sony Service Centre Note For instructions on how to access the XDCAM website refer to the following section o
4. Memory Stick DUO and Memory Stick Micro can also be used provided a suitable adaptor is used 2 Confirm the software version as described in Section 2 11 2 ROM Version Check of the Service Manual 12 PDW F335 F355 12 1 AT Package FRESH COPRO CLEAN Software Note This procedure can be used to upgrade the following software product combinations AT PDW F335 F355 Package PDW F335 F355 FRESH PDW F355 COPRO PDW F355 CLEAN PDW F355 For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal 1 Upgrade the software as described in Section 2 12 Memory Stick AT PACKAGE FRESH COPRO CLEAN of the PDW F335 F355 Service Manual Volume 1 1st Edition Revision 1 part number 9 968 386 02 Note Usea 16 32 64 or 128MB standard memory stick or MagicGate memory stick or Memory Stick PRO up to 2GB Memory Stick DUO and Memory Stick Micro can also be used provided a suitable adaptor is used 2 Confirm the software versio
5. 1 Decompress the ZIP file to a temporary folder on the Apple Mac computer 2 Open the disk image dmg file 3 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 21 of 21
6. XDCAM Transfer FAM Driver Apple Mac When swapping discs between the PDW 700 and other XDCAM models in the PDW series ensure that all models have been upgraded to their latest respective software versions 1 2 Open TOP MENU gt DIAGNOSIS gt ROM VERSION 1 and confirm that software package V1 2 or higher is installed If an earlier version is installed contact your local Sony Service Centre Perform FILE ALL SAVE to save the current menu settings to a memory stick as described in Section 4 7 FILE Menu of the PDW 700 Maintenance Manual Volume 1 Edition 1 part number 9 968 417 01 Upgrade the software as described in Section 1 11 2 Firmware Update Using the USB Memory of the Maintenance Manual 10 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 4 Confirm the software version from the TOP MENU gt DIAGNOSIS gt ROM VERSION 1 page 5 Perform FILE ALL LOAD to restore the current menu settings from the memory stick as described in Section 4 7 FILE Menu of the Maintenance Manual 7 2 Package Software upgrade by Ethernet Caution Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compati
7. at the rear of the main unit Press and hold down the lt button and then press the MENU button to open the MAINTENANCE MENU Use the t buttons to select OTHERS and then press the button Use the t buttons to select SOFTWARE VERSION and then press the gt button 13 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 8 10 11 12 13 14 15 Press and hold down the SHIFT button and then press the SET button to display the PACKAGE UPDATE screen PACKAGE UPDATE CURRENT NEW VERSION VERSION a aa gt b bb VERSION UP OK UPDATE SET KEY ABORT RESET KEY Confirm the new version is correct and then press the SET button The version upgrade will start automatically Caution The upgrade will take approximately 14 minutes to complete and may appear to freeze part way for several minutes This is normal Do NOT turn off the power or remove the memory stick until COMPLETE is displayed Wait until COMPLETE is displayed and then turn the main power OFF and ON Press and hold down the lt button and then press the MENU button to open the MAINTENANCE MENU Use the t buttons to select OTHERS and then press the button Use the t buttons to select SOFTWARE VERSION and then press the gt button Confirm the software version is correct Restore the menu settings as described in Section 4 3 3 LOAD MENU DATA of the Serv
8. confirm that software package V1 2 or higher is installed If an earlier version is installed contact your local Sony Service Centre 2 Save the current menu settings into one of the BANK memories as described in the following section of the PDW HD1500 Operation Manual part numbers 3 282 299 01 or 3 282 295 03 Section 7 Menus gt Setup Menu gt Basic Setup Menu items B11 B13 3 Upgrade the software as described in Section 3 3 1 Software Update of the PDW HD1500 Maintenance Manual Volume 1 Edition 1 part number 9 968 423 01 4 Confirm the software version as described in Section 3 2 3 Software Version of the Maintenance Manual or from the MAINTENANCE MENU gt M30 SOFTWARE VERSION 5 Restore the menu settings from the BANK memory as described in the following section of the Operation Manual Section 7 Menus gt Setup Menu gt Basic Setup Menu items BO1 B13 17 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 14 PDW R1 14 1 Package Software Caution Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the foll
9. internal temperature may rise because the fan inside the unit does not operate during the upgrade The camcorder must be switched OFF and ON immediately after UPDATE COMPLETED is displayed 6 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 6 2 1 Normal Procedure 1 2 Turn the main power ON Set the MENU switch from OFF to ON whilst pressing down the MENU knob to open the TOP MENU Select DIAGNOSIS gt ROM VERSION 1 and confirm that PACKAGE V1 180 or higher is displayed If an earlier version is installed contact your local Sony Service Centre Use a PC to create the following folder structure on a memory stick AMSSONY PRO CAMERA PDW530 Note Units with AT V1 50 or lower can use only a 16 32 64 or 128MB standard memory stick or MagicGate memory stick Memory Stick PRO is NOT supported Units with AT V1 51 or higher can use all memory sticks with sizes between 16MB and 2GB including Memory Stick PRO provided the BOOT program has already been upgraded to V1 10 or higher Refer to Section 6 1 for further details Memory Stick DUO and Memory Stick Micro can also be used provided a suitable adaptor is used Copy the PDW530at rom file to the PDW530 sub folder created in step 4 Upgrade the softwar
10. the minimum requirements specified in the ReadMe file 8 2 MAC Utility Program Apple Mac 1 Install the latest PDZK P1 XDCAM Transfer FAM Driver software 2 Decompress the ZIP file to a temporary folder on the Apple Mac computer 3 Open the disk image dmg file 4 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 8 3 Package Software Caution Do NOT turn off the power or disconnect the i Link cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Note For full compatibility it is recommended that the latest version of the PC MAC Utility Program is installed 11 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 1 Upgrade the software as described in the PDW D1 e Manual part number 9 968 069 71 Note Ifan installation key has not been supplied leave the Installation Key box blank The installation procedure is described under the following section of the e Manual Main Menu Service Overview Firmware Software Firmware Update 2 Confirm the software version in the DEVICE INFORMATION gt VERSION screen of the PC MAC Utility Program 9 PDW F30 F70 70MD 9 1 Package Software Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Discon
11. 1 3 2 System Requirements of the Operation Manual part numbers 3 281 393 11 or 4 131 292 01 Note For full compatibility it is recommended that the latest version of PDZK P1 XDCAM Transfer FAM Driver is installed 1 If an old version of the U1 Utility has been installed open Finder gt Applications select U1 Utility and drag it to Trash 2 Double click the U1Utility pkg file from the U1_ Utility sub folder Follow the on screen instructions 18 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 15 3 Firmware Package Caution 1 2 Do NOT turn off the power or disconnect the USB cable during the upgrade Do NOT upgrade the firmware with a disc inserted in the unit Install the software as described in Section 1 14 Firmware Update of the PDW U1 Maintenance Manual Volume 1 Edition 1 Revision 2 part number 9 968 377 03 Note The PDW U1 is upgraded from the U1 Utility via the USB port The Firmware Package software is already embedded inside the U1 Utility software which is available for both Windows and Apple Mac If an old version of the U1 Utility has been installed it must be uninstalled before installing the latest version Refer to Sections 15 1 and 15 2 for further details Confirm the software version in DRIVE MAINTENANCE gt OTHERS gt VERSION 15 4 PDW Terminal Service Tool Windows Note For full compatibility it is recommended that the latest version of PDZ 1 Proxy Browser
12. 75 75MD 10 1 Package Software Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac NET software for the PDBK 101 Network Board if fitted Package software for the PDBK 102 TS Input Output Board if fitted If the menu screens are hidden press the DISPLAY button to switch the LCD screen to TIME DATA display 1 Save the current menu settings as described in Section 4 3 2 SAVE MENU DATA of the PDW F75 75MD Service Manual Volume 1 1st Edition Revision 1 part number 9 968 379 02 Note Alternatively the current menu settings can be stored in one of the three BANK memories as described in Chapter 6 Menus of the Operation Manual This feature is not available for the PDW 75MD Use a PC to create the following folder structure on a memory stick MSSONY PRO XDCAM PDWF70 Note Fora list of compatible memory stick types refer to Section 1 23 Memory Stick of the Service Manual Copy the package data file to the folder created in step 2 Insert the memory stick into the memory stick slot
13. NTENANCE MENU 12 Use the t J buttons to select OTHERS and then press the button 13 Use the t J buttons to select SOFTWARE VERSION and then press the gt button 14 Press the button several times until the TS version is displayed 15 Confirm the software version is correct 4 PDBZ E1500 LINEAR EDIT OPTIONAL SOFTWARE 4 1 Applicable Model The PDBZ E1500 Linear Edit Optional Software can be installed in the following model PDW 1500 4 2 Package Software This software should be installed using the installation procedure described in Section 5 1 except that a valid install key must be entered Install Keys can be purchased from your local Sony dealer 5 PDW 1500 5 1 Package Software This procedure can only be used to upgrade from Package V1 180 or higher If an earlier version is installed contact your local Sony Service Centre Caution Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 1 Verify software package V1 180 or higher is installed in the STATUS gt
14. SOFTWARE VERSION screen of the XDCAM web site or from the MAINTENANCE gt OTHERS gt SOFTWARE VERSION menu If an earlier version is installed contact your local Sony Service Centre Note For instructions on how to access the XDCAM website refer to the following section of the PDW 1500 e Manual part number 9 968 030 7 1 Main Menu Service Overview Others Information XDCAM Web Site XDCAM Web Site Overview 2 Save the current menu settings into one of the BANK memories as described in the following sections of the PDW 1500 Operation Manual Edition 1 Revision 6 part numbers 3 796 075 07 or 3 796 077 07 Section 8 2 1 Items in the Basic Setup Menu items B11 B13 Section 8 2 2 Basic Menu Operation 4 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 3 Upgrade the software as described in the e Manual using the file listed in Table 2 which correlates to the serial number of the disc recorder Table 2 PDW 1500 Software Package 10001 19999 garland pdw 1500 xxxx pkg 20001 and higher garland pdw 1500 s1 xxxx pkg XXxxX software version Note Ifan install key has not been supplied leave the Software Install Key box blank The installation procedure is described under the following section of the e Manual Main Menu Service Overview Firmware Software Firmware Update 4 Confirm the software version in the STATUS gt SOFTWARE VERSION screen of the XDCAM web si
15. bility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac When swapping discs between the PDW 700 and other XDCAM models in the PDW series ensure that all models have been upgraded to their latest respective software versions 1 Open TOP MENU gt DIAGNOSIS gt ROM VERSION 1 and confirm that software package V1 2 or higher is installed If an earlier version is installed contact your local Sony Service Centre 2 Perform FILE ALL SAVE to save the current menu settings to a memory stick as described in Section 4 7 FILE Menu of the PDW 700 Maintenance Manual Volume 1 Edition 1 part number 9 968 417 01 3 Upgrade the software as described in Section 2 3 1 Software Update of the Maintenance Manual 4 Confirm the software version as described in Section 2 2 3 Software Version of the Maintenance Manual or from the TOP MENU gt DIAGNOSIS gt ROM VERSION 1 page 5 Perform FILE ALL LOAD to restore the current menu settings from the memory stick as described in Section 4 7 FILE Menu of the Maintenance Manual 8 PDW D1 8 1 PC Utility Program Windows 1 Install the latest PDZ 1 Proxy Browser and FAM Driver software 2 Decompress the ZIP file to a temporary folder on the PC 3 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets
16. d as shown under the following section of the e Manual Main Menu Service Overview Firmware Software Software Update Camera Software Update AT 154 board Turn the main power ON The green lamp D1 on the MS 69 jig will light up and then turn off several seconds later Wait until the green lamp D1 has turned off and then turn the main power OFF Disconnect the MS 69 jig Upgrade the MAIN program to AT V1 51 or higher as described in Section 6 2 6 1 2 Parts Required Table 3 Parts Required MS 69 jig A 8347 484 B 1 IC 29F040 PDW510 MS9 V1 10 6 807 816 01 IC9 MS 69 jig BOOT V1 10 checksum EA9B 1 IC 29F040 PDW510 MS10 V1 10 6 807 817 01 1C10 MS 69 jig BOOT V1 10 checksum D83E Note It is also possible to use an MS 69A jig part number A 1356 823 A to upgrade the BOOT Program provided IC9 and IC10 are replaced using the ROMs listed in Table 3 6 2 AT Software MAIN Program These procedures can only be used to upgrade a unit with Package V1 180 or higher If an earlier version is installed contact your local Sony Service Centre Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal The
17. d in the following section of the PDW HD1500 Operation Manual part numbers 3 282 299 01 or 3 282 295 03 Section 7 Menus gt Setup Menu gt Basic Setup Menu items B11 B13 3 Upgrade the software as described in Section 1 10 Firmware Update of the PDW HD1500 Maintenance Manual Volume 1 Edition 1 part number 9 968 423 01 4 Confirm the software version in the MAINTENANCE MENU gt M30 SOFTWARE VERSION 5 Restore the menu settings from the BANK memory as described in the following section of the Operation Manual Section 7 Menus gt Setup Menu gt Basic Setup Menu items BO1 B13 13 2 Package Software upgrade by Ethernet Caution Do NOT turn off the power or disconnect the network cable during the upgrade Note Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac When swapping discs between the PDW HD1500 and other XDCAM models in the PDW series ensure that all models have been upgraded to their latest respective software versions 1 Open MAINTENANCE MENU gt M30 SOFTWARE VERSION and
18. diately perform steps 7 to 9 of Section 6 2 1 7 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 6 3 Package Software from V1 450 and higher upgrade by memory stick This procedure can only be used to upgrade from Package V1 450 or higher If an earlier version is installed refer to Section 6 4 Caution Note Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac Turn the main power ON Set the MENU switch from OFF to ON whilst pressing down the MENU knob to open the TOP MENU Select DIAGNOSIS gt ROM VERSION 1 and confirm that PACKAGE V1 450 or higher is displayed If an earlier version is installed refer to Section 6 4 Use a PC to create the following folder structure on a memory stick AMSSONY PRO CAMERA PDW530 Note Units with AT V1 50 or lower can use only a 16 32 64 or 128MB standard memory stick or MagicGate memory stick Memory Stick PRO is NOT supported Units with AT V1 51 or higher can use all memory stick
19. e using a memory stick as described under the following section of the PDW 510 510P 530 530P 539P e Manual part number 9 968 032 71 Main Menu Service Overview Firmware Software Software Update Camera Software Update AT 154 board Note If FILE NOT FOUND is continually displayed whilst attempting to upgrade the software check that is displayed to the left of DO3 If an arrow is displayed instead of press the ROTARY ENCODER to toggle the display Next re insert the memory stick Wait until MEMORYSTICK ACCESS disappears from the viewfinder and then immediately press and hold in the ROTARY ENCODER until the software version is displayed If the memory stick is larger than 128MB and it is not recognised the BOOT Program may need to be upgraded to V1 10 Refer to Section 6 1 for further details Turn the main power OFF and ON Set the MENU switch from OFF to ON whilst pressing down the MENU knob to open the TOP MENU Confirm the software version in TOP MENU gt DIAGNOSIS gt ROM VERSION 1 6 2 2 Forcible Procedure This procedure should only be used if the procedure in Section 6 2 1 fails 1 2 3 4 5 Perform steps 1 to 5 of Section 6 2 1 Turn the main power OFF Insert the memory stick Turn the main power ON whilst holding down the REC START STOP BUTTON and ROTARY ENCODER The software update process will start automatically Wait until UPDATE COMPLETED is displayed and then imme
20. ecompress the ZIP file to a temporary folder on the PC 2 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 20 2 Binary Package Caution Do NOT turn off the power or disconnect the USB cable during the upgrade Do NOT upgrade the software unless the unit is powered from the mains 1 Decompress the ZIP file to a temporary folder on the PC 2 Install the software as described in the ReadMe file 20 3 SxS PRO Device Driver Windows 1 Decompress the ZIP file to a temporary folder on the PC 2 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 20 4 SxS PRO Device Driver Apple Mac 1 Decompress the ZIP file to a temporary folder on the Apple Mac computer 2 Open the disk image dmg file 3 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 21 XDZ P1 21 1 XDCAM EX Clip Browser Windows 1 Decompress the ZIP file to a temporary folder on the PC 2 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 21 2 XDCAM EX Clip Browser Apple Mac
21. ed Qty Description Part Number 1 MS 69A jig A 1356 823 A 11 2 AT Package and FRESH Software Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 15 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 1 Upgrade the software as described in Section 2 12 Memory Stick AT PACKAGE FRESH of the PDW F330 F350 Service Manual Volume 1 1st Edition part number 9 968 253 01 Note Units with AT V1 53 or lower can use only a 16 32 64 or 128MB standard memory stick or MagicGate memory stick Memory Stick PRO is NOT supported Units with AT V1 54 or higher can use all memory sticks with sizes between 16MB and 2GB including Memory Stick PRO provided the BOOT program has already been upgraded to V1 54 or higher Refer to Section 11 1 for further details If the memory stick is larger than 128MB and it is not recognised the BOOT Program may need to be upgraded to V1 54 Refer to Section 11 1 for further details
22. evision 2 part number 9 968 227 03 PDW F75 75MD Service Manual Volume 1 Edition 1 Revision 1 part number 9 968 379 02 2 Copy the data file F70TSPK ROM to the folder created in step 1 Insert the memory stick into the memory stick slot at the rear of the main unit Press and hold down the lt button and then press the MENU button to open the MAINTENANCE MENU Use the t buttons to select OTHERS and then press the button Use the t buttons to select SOFTWARE VERSION and then press the gt button Press the button several times until the TS version is displayed Press and hold down the SHIFT button and then press the SET button to display the TS UPDATE screen Pe Os ODO TS UPDATE PDBK 102 CURRENT NEW VERSION VERSION a aa gt b bb VERSION UP OK UPDATE SET KEY ABORT RESET KEY 3 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 9 Confirm the new version is correct and then press the SET button The version upgrade will start automatically Caution The upgrade will take approximately 5 minutes to complete and may appear to freeze at 0 or part way for several minutes This is normal Do NOT turn off the power or remove the memory stick until COMPLETE is displayed 10 Wait until COMPLETE is displayed and then turn the main power OFF and ON 11 Press and hold down the button and then press the MENU button to open the MAI
23. f the PDW V1 e Manual part number 9 968 029 7 1 Main Menu Service Overview Others Information XDCAM Web Site XDCAM Web Site Overview Save the current menu settings into one of the BANK memories as described in the following sections of the PDW V1 Operation Manual part numbers 3 796 066 07 or 3 796 068 07 Section 7 2 1 Basic Setup Menu items B11 B13 Section 7 2 2 Basic Menu Operation 19 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 3 Upgrade the software as described in the e Manual with the following exceptions Use a crossover network cable only If an install key has not been supplied leave the Software Install Key box blank Note The installation procedure is described under the following section of the e Manual Main Menu Service Overview Firmware Software Firmware Update 4 Restore the menu settings from the BANK memory as described in Sections 7 2 1 and 7 2 2 of the Operation Manual Note This process will automatically initialise the menu settings If the default menu settings are preferred they will need to be initialised as follows a Execute menu item MAINTENANCE gt SETUP MAINTENANCE gt RESET ALL SETUP b Turn the main power OFF and ON c Set the operation mode 525U 525J 625 as described in Section 7 2 2 of the Operation Manual 5 Confirm the software version in the STATUS gt SOFTWARE VERSION screen of the XDCAM web si
24. fore upgrading the software Noise may be audible during the upgrade this is normal Note The upgrade procedure for BOOT Program V1 10 is different to the procedure described under the following section of the PDW 510 510P 530 530P 539P e Manual part number 9 968 032 7 1 Main Menu Service Overview Firmware Software Software Update Camera Software Update AT 154 board 5 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 7 8 9 10 11 Remove all memory sticks from both the MS 69 jig and the camcorder if fitted Confirm the version on the ROM labels for IC9 and IC10 on the MS 69 jig is V1 10 or higher If the version is lower than V1 10 replace both ROMs Ensure the necessary antistatic precautions are taken when handling the ROMs Note The model PDW 510 is printed on the ROM label but the jig can be used for PDW 510 510P 530 530P It is also possible to use an MS 69A jig to upgrade the BOOT Program provided IC9 and IC10 are replaced using the ROMs listed in Table 3 Set switch S1 on the MS 69 jig to the lower position labelled position 1 Caution This setting is different to the procedure described in the e Manual Turn the main power OFF Open the inside panel assembly as shown under the following section of the e Manual Main Menu Service Overview Others Information Removing Exterior Parts Opening Closing Inside Panel Connect the MS 69 jig to the AT 154 boar
25. ice Manual Note If the menu settings were stored in one of the BANK memories restore the menu settings as described in Chapter 6 Menus of the Operation Manual 11 PDW F330 F350 11 1 BOOT Program V1 54 and AT MAIN Program BOOT Program V1 54 is required when the MAIN program is upgraded to AT V1 54 or higher This software upgrade provides support for memory sticks up to 2GB including Memory Stick PRO Caution If the AT software is upgraded to V1 54 or higher without upgrading the BOOT Program to V1 54 the unit may not operate correctly 11 1 1 Installation Procedure Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note The following procedure updates both the BOOT program and AT software A separate procedure for updating the AT Package and FRESH software is described in Section 11 2 1 Use a PC to create the following folder structure on a memory stick AMSSONY PRO CAMERA PDWF350 14 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 2 Copy the data files BOOT ROM and F350AT ROM to the folder created in step 1 Note Units with AT V1 53 or lower can use only a 16 32 64 or 128MB standard memo
26. knob to open the TOP MENU Confirm the software version in TOP MENU gt DIAGNOSIS gt ROM VERSION 1 Configure the DRIVE Hours Meter as described in Section 6 5 6 4 Package Software upgrade by Ethernet via CBK NC01 Network Adapter This procedure can only be used to upgrade from Package V1 180 or higher If an earlier version is installed contact your local Sony Service Centre Caution Note Do NOT turn off the power or disconnect the network cable during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal This procedure can only be used if a CBK NC01 Network Adapter is fitted For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac Verify software package V1 180 or higher is installed in the STATUS gt SOFTWARE VERSION screen of the XDCAM web site If an earlier version is installed contact your local Sony Service Centre Note For instructions on how to access the XDCAM website refer to the following section of the PDW 510 510P 530 530P 539P e Manual part number 9 968 032 7 1 Main Menu Service Overview Others Information XDCAM Web Si
27. n 1 Revision 1 part number 9 968 379 02 2 Confirm the software version as described in Section 3 2 3 Software Version of the Service Manual 2 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 3 PDBK 102 TS INPUT OUTPUT BOARD 3 1 Applicable Models The PDBK 102 TS Input Output Board can be installed in the following models PDW 70MD PDW 75MD PDW F30 PDW F70 PDW F75 3 2 Package Software TSI 54 board Note Itis not necessary to save the current menu settings before installing this software because no menu settings are affected Caution Do NOT turn off the power or remove the memory stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note Ifthe menu screens are hidden press the DISPLAY button to switch the LCD screen to TIME DATA display For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 1 Use a PC to create the following folder structure on a memory stick MSSONY PRO XDCAM PDWEF70 Note For alist of compatible memory stick types refer to Section 1 23 Memory Stick of the respective Service Manual PDW F30 F70 70MD Service Manual Volume 1 Edition 1 R
28. n as described in Section 2 11 2 ROM Version Check of the Service Manual 3 Performa FACTORY PRESET as described in Section 4 2 SERVICE Menu of the Service Manual 13 PDW HD1500 These procedures can only be used to upgrade a unit with Package V1 2 or higher If an earlier version is installed contact your local Sony Service Centre 16 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 13 1 Package Software upgrade by USB stick Caution Do NOT turn off the power or remove the USB stick during the upgrade Note Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac When swapping discs between the PDW HD1500 and other XDCAM models in the PDW series ensure that all models have been upgraded to their latest respective software versions 1 Open MAINTENANCE MENU gt M30 SOFTWARE VERSION and confirm that software package V1 2 or higher is installed If an earlier version is installed contact your local Sony Service Centre 2 Save the current menu settings into one of the BANK memories as describe
29. nect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal Note For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac NET software for the PDBK 101 Network Board if fitted Package software TSI 54 board for the PDBK 102 TS Input Output Board if fitted If the menu screens are hidden press the DISPLAY button to switch the LCD screen to TIME DATA display 1 Save the current menu settings as described in Section 4 3 2 SAVE MENU DATA of the PDW F30 F70 70MD Service Manual Volume 1 1st Edition Revision 2 part number 9 968 227 03 Note Alternatively the current menu settings can be stored in one of the three BANK memories as described in Chapter 6 Menus of the Operation Manual This feature is not available for the PDW 70MD 2 Usea PC to create the following folder structure on a memory stick MSSONY PRO XDCAM PDWF70 Note Fora list of compatible memory stick types refer to Section 1 23 Memory Stick of the Service Manual 3 Copy the package data file to the folder created in step 2 4 Insert the memory stick into the memory stick slot at the rear of the main unit 5 Press and hold down the button and then press the MENU button to open the MAINTENANCE MENU 6 Usethe t J but
30. owing software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1 XDCAM Transfer FAM Driver Apple Mac 1 Upgrade the software as described in Section 1 16 Firmware Update of the PDW R1 Maintenance Manual Volume 1 1st Edition Revision 2 part number 9 968 264 03 Note Ifan installation key has not been supplied leave the Installation Key box blank 2 Confirm the software version as described in the Maintenance Manual 15 PDW U1 15 1 U1 Utility Sony XDCAM Driver Software Windows Caution Do not install this software unless the computer meets the minimum requirements specified in Section 1 3 2 System Requirements of the Operation Manual part numbers 3 281 393 11 or 4 131 292 01 Note For full compatibility it is recommended that the latest version of PDZ 1 Proxy Browser FAM Driver is installed 1 If an old version of the U1 Utility has been installed use Add or Remove Programs from the Control Panel to remove Sony XDCAM Drive Software and then restart the PC Note The Windows version of the U1 Utility is also referred to as Sony XDCAM Drive Software 2 Run Setup exe from the XDCAM Drive Software sub folder 3 Follow the on screen instructions Caution The computer must be rebooted after installing the U1 Utility 15 2 U1 Utility Apple Mac Caution Do not install this software unless the computer meets the minimum requirements specified in Section
31. ry stick or MagicGate memory stick Memory Stick PRO is NOT supported Units with AT V1 54 or higher can use all memory sticks with sizes between 16MB and 2GB including Memory Stick PRO provided the BOOT program has already been upgraded to V1 54 or higher Refer to Section 11 1 for further details Memory Stick DUO and Memory Stick Micro can also be used provided a suitable adaptor is used Insert the memory stick into the memory stick slot of the MS 69A jig Set switch S1 to position 0 Turn the main power OFF Open the inside panel as described in Section 2 7 3 Inside Panel of the PDW F330 F350 Service Manual Volume 1 1st Edition part number 9 968 253 01 Connect the MS 69A jig to CN11 on the DCP 37 37A board Side A location D3 8 Turn the main power ON 9 The version upgrade will start automatically and the following sequence of messages will be displayed at the top of the LCD screen Note Ifthe memory stick is larger than 128MB and it is not recognised the BOOT Program may need to be upgraded to V1 54 Refer to Section 11 1 for further details On kw lt BOOT BLOCK UPDATE gt Vv lt BOOT BLOCK UPDATE gt COMPLETED v lt FIRMWARE UPDATE gt v lt FIRMWARE UPDATE gt COMPLETED 10 Wait until FIRMWARE UPDATE has COMPLETED and then turn the main power OFF 11 Disconnect the MS 69A jig 12 Close the inside panel 11 1 2 Parts Required Table 6 Parts Requir
32. s with sizes between 16MB and 2GB including Memory Stick PRO provided the BOOT program has already been upgraded to V1 10 or higher Refer to Section 6 1 for further details Memory Stick DUO and Memory Stick Micro can also be used provided a suitable adaptor is used Copy the appropriate PKG file in Table 4 to the PDW530 sub folder created in step 4 Table 4 Software Package Files for Upgrade by Memory Stick Products Serial No Original File Name PDW 510 510P 40001 41999 wreath 510 xxxx pkg 42000 and higher PDW 510 510P 60000 and higher wreath 510 s1 xxxx pkg PDW 530 530P 40001 41999 wreath 530 xxxx pkg 42000 and higher PDW 530 530P 60000 and higher wreath 530 s1 xxxx pkg XxXxxX software version For PDW 510 510P rename the PKG file to pdw510pk rom For PDW 530 530P rename the PKG file to pdw530pk rom Upgrade the software as described in the PDW 510 510P 530 530P 539P e Manual part number 9 968 032 71 Note The installation procedure is described under the following section of the e Manual Main Menu Service Overview Firmware Software Software Update VDR Software Update Note If the memory stick is larger than 128MB and it is not recognised the BOOT Program may need to be upgraded to V1 10 Refer to Section 6 1 for further details 8 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 10 Set the MENU switch from OFF to ON whilst pressing down the MENU
33. switch S202 1 on the AT 154 board to ON 3 Turn the power ON 4 Open the SERVICE menu and select SOO CONTENTS gt 20 VDR MAINTENANCE gt S20 DRIVE MAINTE 5 When MAINTENANCE START is displayed move the cursor to YES and then press the menu knob 6 Select OTHERS 7 Rotate the menu knob to scroll down to the last item on the page Continue to rotate the menu knob until MEMORY SUPPORT is displayed and then select it 8 Rotate the menu knob to scroll down and select MAINTENANCE HOURS 9 Select CONVERT HOURS and execute according to the instruction in the menu 10 Select MAINTENANCE HOURS and confirm that CONVERT HOURS is not displayed Note Once the CONVERT HOURS menu has been executed it is not displayed again 7 PDW 700 These procedures can only be used to upgrade a unit with Package V1 2 or higher If an earlier version is installed contact your local Sony Service Centre 7 1 Package Software upgrade by USB stick Caution Note Do NOT turn off the power or remove the USB stick during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables before upgrading the software Noise may be audible during the upgrade this is normal For full compatibility it is recommended that the latest versions of the following software are installed PDZ 1 Proxy Browser FAM Driver Windows PDZK P1
34. te XDCAM Web Site Overview Upgrade the software as described in the e Manual using the file listed in Table 5 which correlates to the serial number of the camcorder Table 5 Software Package Files for Upgrade by Ethernet Products Serial No File Name PDW 510 510P 40001 41999 garland pdw 51 0 xxxx pkg 42000 and higher PDW 510 510P 60000 and higher garland pdw 510 s1 xxxx pkg PDW 530 530P 40001 41999 garland pdw 530 xxxx pkg 42000 and higher PDW 530 530P 60000 and higher garland pdw 530 s1 xxxx pkg XxXxxX software version Note Ifan install key has not been supplied leave the Software Install Key box blank The installation procedure is described under the following section of the e Manual Main Menu Service Overview Firmware Software Software Update VDR Software Update via Network only when CBK NCO1 is installed 9 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 4 Confirm the software version from the STATUS gt SOFTWARE VERSION screen of the XDCAM web site Note Ifthe old version is displayed on the XDCAM web site press F5 to refresh the browser window Configure the DRIVE Hours Meter as described in Section 6 5 6 5 Configuration of DRIVE Hours Meter Note This procedure only applies to PDW 510 510P 530 530P with the following serial number ranges Serial No 42000 and higher Serial No 60000 and higher 1 Turn the power OFF 2 Set DIP
35. te or from the MAINTENANCE gt OTHERS gt SOFTWARE VERSION menu 17 PDZ 1 17 1 Proxy Browser FAM Driver Windows 1 Decompress the ZIP file to a temporary folder on the PC 2 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 18 PDZK P1 18 1 XDCAM Transfer Software FAM Driver Apple Mac 1 Decompress the ZIP file to a temporary folder on the Apple Mac computer 2 Open the disk image dmg file 3 Install the software as described in the ReadMe file Caution Do not install this software unless the computer meets the minimum requirements specified in the ReadMe file 19 PDZ VX10 19 1 XDCAM Viewer Software Windows Notes PDZ VX10 XDCAM Viewer is for Windows XP SP2 or higher only PDZ VX10 XDCAM Viewer will no longer operate correctly if you subsequently install the PDZ 1 Proxy Browsing Software on the same computer Install PDZ 1 first or reinstall XDCAM Viewer after installing PDZ 1 Decompress the ZIP file to a temporary folder on the PC Close down all applications Click the Windows Start button and then click Run Click the Browse button select the XDCAM Viewer setup exe file and then click OK Follow the on the screen instructions Ch Os rie 20 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 20 PMW EX1 EX3 EX30 20 1 Binary Package Loader Windows 1 D
36. te or from the MAINTENANCE gt OTHERS gt SOFTWARE VERSION menu Note Ifthe old version is displayed on the XDCAM web site press F5 to refresh the browser window 5 Restore the menu settings from the BANK memory as described in Sections 8 2 1 and 8 2 2 of the Operation Manual Note This process will automatically initialise the menu settings If the default menu settings are preferred they will need to be initialised as follows a Execute menu item MAINTENANCE gt SETUP MAINTENANCE gt RESET ALL SETUP b Turn the main power OFF and ON c Set the operation mode 525U 525J 625 as described in Section 8 2 2 of the Operation Manual 6 PDW 510 510P 530 530P 6 1 BOOT Program V1 10 BOOT Program V1 10 is required when the MAIN program is upgraded to AT V1 51 or higher This software upgrade provides support for memory sticks up to 2GB including Memory Stick PRO Caution If the AT software is upgraded to V1 51 or higher without upgrading the BOOT Program to V1 10 the unit may not operate correctly 6 1 1 Installation Procedure This procedure can only be used to upgrade a unit with Package V1 180 or higher If an earlier version is installed contact your local Sony Service Centre Caution Do NOT turn off the power during the upgrade Do NOT upgrade the software with a disc inserted in the unit Do NOT upgrade the software unless the unit is powered from the mains Disconnect the i Link audio and headphone cables be
37. tons to select OTHERS and then press the button 7 Usethe t J buttons to select SOFTWARE VERSION and then press the button 8 Press and hold down the SHIFT button and then press the SET button to display the PACKAGE UPDATE screen PACKAGE UPDATE CURRENT NEW VERSION VERSION a aa gt b bb VERSION UP OK UPDATE SET KEY ABORT RESET KEY 12 of 21 SOFTWARE INSTALLATION PROCEDURES FOR XDCAM E PDW 001 5 10 11 12 13 14 15 Confirm the new version is correct and then press the SET button The version upgrade will start automatically Caution The upgrade will take approximately 14 minutes to complete and may appear to freeze part way for several minutes This is normal Do NOT turn off the power or remove the memory stick until COMPLETE is displayed Wait until COMPLETE is displayed and then turn the main power OFF and ON Press and hold down the button and then press the MENU button to open the MAINTENANCE MENU Use the t buttons to select OTHERS and then press the button Use the t buttons to select SOFTWARE VERSION and then press the button Confirm the software version is correct Restore the menu settings as described in Section 4 3 3 LOAD MENU DATA of the Service Manual Note If the menu settings were stored in one of the BANK memories restore the menu settings as described in Chapter 6 Menus of the Operation Manual 10 PDW F