Home
Monitor AutoWhiteAdjustment
Contents
1. gl Monitor_AutowhiteAdjustment ex File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Peer to Peer Luminance Y LAN Monitor Selection Target Monitor List Model Name LMD A220 Color Temp Monitor ID 7 c t Gomneci J x 0 313 IP Address 192 168 0 7 y 0 329 Set to Measured Data v Probe Setup O Offset E Auto Offset More Info Probe xij Dya Reference LCD BVM L Status Not Connected Luminance Y 100 Highlight FT Y Adjustment Display of the luminance setting is different from the PVM and LMD series Setting Probe If you use a probe to perform the automatic color temperature adjustments or color temperature measurement you will need to select a probe and as necessary calibrate it For details about available probes see page 3 Selecting a probe When you click the 7 to the right of Probe a list of probes appears x gl Monitor_AutowhiteAdjustment File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Peer to Peer Luminance Y LAN Monitor Selection Target Manhor List Sa act Model Name BVM E170 zza Color Temp Monitor ID 1 sonnets x 0 313 IP Address m rak y 0 329 Set to Measured Data x Probe Setup s m Offset FT Auto Offset More Info Probe s SS Stat X Rite it Pro i1 Pro2 Reference CRT BVM A F D as Konica Minolta CS
2. followings e Decrease or increase the luminance target value increase decrease e Adjust the color temperature target value backlight LMD and LMD A series only decrease increase Y If it is not improved perform the calibration again change x y Adjustment failed Automatic color temperature adjustment was attempted but failed Please try again Confirm monitor settings or the probe position and status Target luminance is too high The target luminance is too high Change the target luminance To avoid this error change the target luminance to lower value to a lower value For details about the target luminance see page 11 Luminance should be targeted to less than xxx cd m2 Target luminance is too low The target luminance is too low Change the target luminance To avoid this error change the target luminance to higher value to a higher value For details about the target luminance see page 11 Luminance should be targeted to more than xxx cd m2 Current luminance is out of The current luminance is too high or low range Current luminance is To avoid this error increase decrease the contrast or brightness adjustment value xxx cd m2 Refer to the chart until the measured luminance value is in proper range while measuring luminance Acceptable target value in by using the probe the user s guide This can be Set the luminance manually to within the target luminance range in advance acc
3. When Y Adjustment is checked Color temperature and luminance are adjusted Color temperature and luminance are adjusted to the specified target value When Y Adjustment is not checked Only color temperature is adjusted Color temperature is adjusted to the specified target value Luminance retains the values before adjustment When adjusting luminance for a PVM LMD series monitor check Y Adjustment Also set CONTRAST and BRIGHTNESS of SUBCONTROL in the USER CONTROL menu of the monitor back to the default 0 For the PVM A series the gain bias adjustment value and contrast brightness adjustment value of color temperature for User2 are adjusted Operations 1 1 e For the LMD A series the gain bias adjustment value contrast brightness adjustment value and backlight adjustment value of color temperature for User2 are adjusted Setting offset values You can set an offset for the target values Setting offset values enables you to compensate for the difference between the displays For details see To Equalize Colors on Different Types of Displays page 12 When a preset item such as D65 etc other than Measured Data is selected from the Set to list the optimal setting is selected automatically depending on the monitor being adjusted The offset values are set for guidance but you can change them Any changed values are saved automatically
4. Monitor_ AutoWniteAdjustment USER S GUIDE Version 1 2 2 Table of Contents OVERVIEN ai a a 3 Foaie pode E 3 SUPPOLteEC DEVICES seinn ennen 3 Computer Environment sssssssssrrrrsrrrrrrrrrrrrrrrrrr 3 Preparation ERSSON TRENTER ROR ARTS 4 Installing the Middleware and the Device Driver FORE PrOB Es are Aare RR R REAL 4 Installing Monitor_AutoWhiteAdjustment 4 Connecting the Monitor to the Computer 5 Connecting the Probe to the Computer 5 OBETAUONS osi ORO OIL A 6 Starting Monitor_AutoWhiteAdjustment 6 ELLIO INCI WORK GA a Gidl 6 Selecting the Monitor eeeaaaaaaaaaaa aaa aaa anawa 7 SEM PPO DS akad Ski 9 Measuring Color Temperature 1 10 Adjusting Color Temperature PUGOMMATIC ALLY ceine ensei had 11 To Equalize Colors on Different Types of DDS PAYS ists soe ai EA GE O 12 ADDENAD arsen 14 EMOBMESS OCS ak oe rese 14 Troubleshooting wi ORO 17 Table of Contents Overview Features Monitor AutoWhiteAdjustment is software for measuring and adjusting the color temperature and luminance of the monitor The following features are built into this software e Measurement of color temperature and luminance of the monitor e Adjustment of color temperature and luminance using the probe Supported Devices This software is compatible with the following equipment as of July 2014 Monitors BVM series BVM E250 BV
5. Network Color Temp Xx Network Adapter Select Connec tion Type Peer to Peer 1 x 0314 y 0351 Y 48 Highlight Information Yul 4 3 Lowlight Format XYZ 3 Contrast Bright Hold On Picture Preset Preset D Cine Model Name Displays the model name of the connected monitor Monitor Selection During Peer to Peer connection this area is not displayed Information Format information is displayed when the XYZ signal is input Picture Preset information is displayed when Picture Preset is Picture D Cine When connected to a PVM LMD series monitor Example Connection Type LAN r x gl Monitor_AutowhiteAdjustment File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Peer to Peer Luminance Y e LAN Monitor Selection Target Monitor List Model Name LMD 1751W Color Temp Monitor ID 16 ka nnegte x 0313 IP Address Uk ll AAL y 0 329 Set to Measured Data Probe Setup o ma Offset Auto Offset More Info Probe M g Reference CRI LCE Status Not Connected Luminance Y 16 Highlight Y Adjustment Input Signal SDVHDMIYCbCr v Display of the luminance setting is different from the BVM series Select the correct input signal from the Input Signal drop down list When connected to an PVM A LMD A series monitor Example Connection Type LAN
6. yref 0 004 specbos xref yref 0 004 xref 0 006 1211 yref 0 007 al Appearance may be different depending on the probe type its individual characteristics or the observer The above are reference values For details about the LCD of the CCFL backlight refer to the BVM CRT 2 CH00 Konica Minolta calibration standard D65 Univ Sync 3 CH00 Konica Minolta calibration standard Univ Sync Operations 13 Appendix Error Messages Conditions to Probe Probe disconnected disconnection Calibration failure Calibration error Network Network disconnected disconnection Monitor Cannot find the monitor connection failure Probe reading Invalid value error value error Please check the probe Adjustment does Monitor not ready not start Please check monitor status Unconnected CA CA 210 not found 210 or CA 310 CA 310 not found 1 4 Appendix Causes and remedies Communication with the probe becomes unavailable while performing the automatic color temperature adjustments Reconfirm the connection with the probe recalibrate the probe then perform the automatic color temperature adjustments again Hint This alert is displayed while performing the automatic color temperature adjustments If you cannot communicate with the probe while measuring the color temperature the measurement stops and the probe is disconnected If the probe is disconnected during luminance sensor calibra
7. 200 L Konica Minolta CA 210 Se S ER Konica Minolta CA 310 bli Y 100 Highlight DK Technologies PM5639 06 Highlight Klein K 10 27 Lowlight JETI specbos 1211 Photo Research PR 655 PR 670 7 Contrast Bright Hold On Select a probe from the list Do not connect two probes at the same time When measuring and adjusting the CRT or OLED monitor using a probe that has a synchronous mode set the synchronous mode correctly referring the instruction manual of the probe If you select CA 210 or CA 310 you need to connect a computer and probe by USB beforehand The error message CA 210 not found CA 310 not found appears if you select CA 210 or CA 310 while they are not connected To select PM5639 06 select the COM port to which PM5639 06 is connected If you select PM5639 06 the window for selecting the usable serial port is displayed Select the COM port depending on the connection status If you select K 10 or specbos1211 a window is displayed to show the COM port to which the selected probe is assumed to be connected Reselect the COM port as necessary If an error occurs because of disconnection of CA 210 or CA 310 or the COM port is not selected in the COM port selection window of PM5639 06 K 10 or specbos1211 Probe Setup returns to the default blank If you select K 10 do not disconnect the probe before quitting this software Operations 9 10 If you select PM5639 06 d
8. cable referring to the instruction manual of the probe e A CS 200 probe may not be recognized by this software when connected to a computer with the following chipset Intel R 5 Series 3400 Series Chipset Family e When you use the PR 670 by connecting a computer you need to set the aperture setting of the PR 670 to 1 in advance e When you connect a PM5639 06 probe to your computer you need to use the connection cable manufactured by DK Technologies or a special serial communication cable that can supply power to the probe Connection diagram Computer D Sub 9 pin connector male for connecting PM5639 06 USB RS 232C conversion cable not supplied Power supply USB port of the computer etc Preparation 5 6 Operations This software cannot be used if the computer is in sleep mode Before using this software make sure automatic sleep mode is disabled If the computer goes into sleep mode while using this software restart the software and probe For LMD 4251TD or LMD 2451TD be sure to select 2D in 2D 3D SELECT before performing adjustment For the following models be sure to select 2D in 2D 3D SELECT and OFF in 3D OFFSET before performing adjustment LMD 2451TD except for China models serial number 3000624 or later LMD 2451TD China models serial number 5000050 or later LMD 4251TD except for China models serial number
9. on all computers or operating systems Screen shots of windows shown in this USER S GUIDE are samples using Windows 7 Their appearance may differ depending on the operating system you use Overview 3 4 NOTICE TO USERS O 2012 2014 Sony Corporation All rights reserved This manual or the software described herein in whole or in part may not be reproduced translated or reduced to any machine readable form without prior written approval from Sony Corporation SONY CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL THE SOFTWARE OR SUCH OTHER INFORMATION IN NO EVENT SHALL SONY CORPORATION BE LIABLE FOR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES WHETHER BASED ON TORT CONTRACT OR OTHERWISE ARISING OUT OF OR IN CONNECTION WITH THIS MANUAL THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF Sony Corporation reserves the right to make any modification to this manual or the information contained herein at any time without notice The software described herein may also be governed by the terms of a separate user license agreement e Microsoft Windows Windows 7 and Windows logo are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries
10. that is not acceptable is set page 11 Please set the acceptable target is invalid value value Target Color Temperature y is invalid value Target Luminance Highlight is invalid value Target Luminance Lowlight is invalid value Target Luminance is invalid value Cannot read SYSTEM file Default file of offset value has been lost for some reason Reinstall Boot failed Please read the Monitor_AutoWhiteAdjustment operation manual Cannot read SYSTEM file Initialization failed Please read the operation manual Not allow several application More than one application may be active If so quit one application activity Change monitor setting Possible causes include the following D Adjustments were performed before the application could update changes of information after channel switching Do not start adjustments immediately after the channel switching After the switching please wait about a second or two and then start adjustments 2 Input signal changed and changes occurred to update the information but the adjustments started before the application updates the changes of information Do not change the input signal during adjustment Target adjustment is out of Color temperature adjustment cannot be performed because the gain bias value used range when adjusting is out of the acceptable range Try one or more of the following Please try from the e Increase or decrease the backlight setting value
11. 3100363 or later LMD 4251TD China models serial number 5100149 or later If you adjust with 3D selected inadvertently change the selection as above and perform adjustment again To switch between 2D 3D or to select for 3D OFFSET refer to the instruction manual of the monitor Starting Monitor_AutoWhiteAdjustment From the Start menu on your computer select All Programs Sony Monitor Utilities then Monitor AutoWhiteAdjustment The software starts and the start up window is displayed r Eg Monitor_AutoWhiteAdjustment Sea File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connec tion Type Luminance Y LAN Monitor Selection Target Monitor List Model Name Not C ted Color Temp Monitor ID 0 313 IP Address y 0 329 Set t Measured Data Probe Setup Se Offset Auto Offset More Inf Probe Reference Status Not Connected Luminance Y 100 Highlight 127 Lowlight 7 Contrast Bright Hold On Operations For the PVM A and LMD A series when starting auto adjustment User2 is selected automatically and an adjustment result is stored When inputting the adjustment value to Userl copy the adjustment value of User2 to User manually after auto adjustment Setting Network Select the network adapter according to the connection environment of the monitor Click Select for Network Adapter The Netwo
12. 5 255 0 e For BVM series when BKM 16R is connected at the same time the IP address of BKM 16R 192 168 0 100 is default cannot be used e For this operation the monitor needs to be set as follows BVM series Set the NETWORK switch on the side of the monitor to PEER TO PEER PVM and LMD series The REMOTE settings in Menu are set as follows SERIAL REMOTE ETHERNET CONNECTION PEER TO PEER PVM A and LMDAA series The Remote settings in Menu are set as follows Serial Remote On Connection Peer to Peer When you select Peer to Peer in Connection Type the Peer to Peer connection is started If the Peer to Peer connection fails click Reconnection for reconnection Checking the connection with the monitor When connection with the monitor 1s established the connection window appears Click OR Operations On screen messages in the connection window e LAN connection X is Monitor ID Connected to Monitor ID X e Peer to Peer connection Connected to Monitor Peer to Peer Monitor selection is complete About setting window The setting window differs depending on the connection type monitor types and setting status When connected to a BVM series monitor Example Connection Type LAN Setting of the monitor Input setting for XYZ signal Picture Preset D Cine r gl Monitor_AutowhiteAdjustment File Maintenance Help Setup Measured Data
13. Color Temperature Automatically You can adjust the color temperature and luminance Before adjustment make sure that all functions of the Function buttons are disabled To enable the automatic color temperature adjustments for an LMD or PVM series monitor the monitor needs to receive a video signal The accuracy of adjustment depends on the performance of the probe or surrounding brightness After performing the automatic color temperature adjustments check visually the black level and white level and if needed adjust the contrast and brightness manually Setting the target value of color temperature and luminance The target values of color temperature need to be set Setting the target value You can set target values in three ways e Using the default target values When the target values are selected from the Set to list the default values are set as the target values Using the measured values of color temperature When color temperature has been measured the measured values can be set as the target values See Setting the measured value as the target value page 10 Inputting values directly Input the values as the text box Fora BVM series monitor if Contrast Bright Hold On has been checked the values of Contrast and Bright set before the adjustment will be restored In this case there may be a difference in the measurement of targeted color temperature and luminance after the adj
14. Intel is the trademark or registered trademark of Intel Corporation in the United States and or other countries All other company names and product names mentioned here may be the trademarks or registered trademarks of their respective companies In this manual TM and R marks are not specified Preparation Preparation Installing the Middleware and the Device Driver for the Probe Install the NET Framework 3 5 SP1 available from the Microsoft website to the computer If you are using any of the following probes additional software or drivers need to be installed i1Pro i1Pro2 Application software supplied with 11Pro manufactured by X Rite or device driver for 1lProl Pro2 CA 210 CA 310 CA SDK software provided by Konica Minolta Device driver for CA 210 CA 310 CS 200 Device driver for CS 200 provided by Konica Minolta PR 655 PR 670 Device driver provided by Photo Research K 10 specbos1211 Device driver for USB to serial conversion chip provided by FTDI Installing Monitor_AutoWhiteAdjustment Consult your nearest Sony dealer when you use this software e Windows administrator privileges are needed to install this software Log in with an administrator account e Depending on your environment permission settings in Windows Firewall or antivirus software may be required If a Windows Firewall warning is displayed select Unblock when prompted Alternatively set the Monitor_AutoWhiteAdjust
15. M E250A BVM E170 BVM E170A BVM F250 BVM F250A BVM F170 BVM F170A PVM series PVM 2541 PVM 2541A PVM 1741 e PVM 1741A PVM 741 PVM 740 PVMAA series PVM A250 PVM A170 LMD series LMD 4251TD LMD 2451TD LMD 2451W except for China models serial number 3000998 or later LMD 2451W China models only serial number 5000164 or later LMD 2051W LMD 1751W LMD 2341W LMD 2041W LMD 1541W LMD 941 LMD 940W except for China models serial number 3004727 or later e LMD 940W China models only serial number 5000637 or later LMDAA series e LMD A240 e LMD A220 e LMD A170 Probes 11Pro 1lPro2 manufactured by X Rite CA 210 CA 310 CS 200 manufactured by Konica Minolta PM5639 06 manufactured by DK Technologies PR 655 PR670 manufactured by Photo Research K 10 manufactured by Klein Optical Instruments Specbos1211 manufactured by JETI Computer Environment A computer with the following specification is needed Operating system OS Microsoft Windows 7 Professional Edition or Ultimate Edition 64 or 32 bit version with SP1 CPU Intel Celeron 1 GHz or higher Memory 1 GB or more Display 1 024 x 768 or more Hi Color 16 bit or more USB port USB 2 0 or higher Hard disk 100 MB free space or more Network Internet connection Middleware NET Framework 3 5 SP1 Available from the Microsoft website The above computer environment does not guarantee correct operation
16. Not Connected Luminance Y 100 Highlight Ni Pars Lowlight 7 Contrast Bright Hold On 1 Click Select The Monitor List window appears and detected monitors are displayed in ID number order Before monitor detection Morel Mame IP Arije Shaw ID Shaw iD OM Cancel If new monitors are detected while displaying the Monitor List window they are added to the window in the order detected 2 Select the monitor you want to adjust from the list then click OR Connection with the selected monitor starts If you click Show ID in the Monitor List window the Monitor ID is displayed on the screen of the monitor connected to the selected network e For this operation the monitor needs to be set as follows BVM series Set the NETWORK switch on the side of the monitor to LAN PVM and LMD series Set the REMOTE settings in Menu as follows SERIAL REMOTE ETHERNET CONNECTION LAN PVM A and LMDAA series Set the Remote settings in Menu as follows Serial Remote On Connection LAN e If the existence of a monitor cannot be confirmed during a certain period of time it will be deleted from the Monitor List window In this case the monitor list will be re sorted in ID number order Selecting a monitor by its Monitor ID You can connect with a monitor by specifying the Monitor ID after the Network Adapter settings are completed and LAN is selected in Connection Typ
17. The offset values can be reset to the default from the Maintenance menu When not setting offset values The target values will be displayed as shown below x gl Monitor_AutowhiteAdjustment Ee File Maintenance Help Setup Measured Data Network Color Temp x 0 309 Network Adapter Select Lesa y 0 329 Connection Type Peer to Peer Luminance Y 143 6 Start Measuring e LAN Monitor Selection Target Model Name BVM E170 Color Temp Monitor List Select Monitor ID 1 Connect x 0 309 IP Address m nap y 0 329 Set to Measured Data z Probe Setup Hepni SEE Offset Auto Offset More Info Probe X Rite i1 Pro it Pro2 SE z rE Reference CRT BVM A F L Status Calibrated Luminance Calibrate z Y 144 Highlight Y 27 Lowlight 71 Contrast Bright Hold On Adjust The target values of the color temperature are the values displayed in the text box When setting offset values When Auto Offset is checked you can set offset values F x gl Monitor_AutowhiteAdjustment en File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select Connection Type Peer to Peer Luminance Start Measuring LAN Monitor Selection Target Model Name BVM E170 Color Temp Monitor List Select Set to Offset Target x 0313 0 004 0 309 IP Address m rap y 0 329 0 013 0 316 Monitor ID 1 Connect Probo Set S
18. e of Network r x gl Monitor_AutowhiteAdjustment EE File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Luminance Y LAN Monitor Selection Target Monitor List Model Name Not Connected Color Temp Monitor ID 1 r LGomeat x 0313 IP Address y 0 329 Set to Measured Data z Probe Setup E oo Offset FT Auto Offset More Info Probe 7 COSA Reference Status Not Connected Luminance Y 100 Highlight 127 Lowlight 7 Contrast Bright Hold On 1 Input a valid value 1 99 for Monitor ID The Connect button become active Operations 7 8 2 Click Connect Searching for a monitor that has the specified Monitor ID starts The message Searching for monitor Please wait appears while searching When the monitor has been detected connection starts If more than one monitor has the same Monitor ID on the same network this software connects with the monitor that is detected first Therefore set a different Monitor ID for each monitor on a network Selecting Peer to Peer connection You can select Peer to Peer connection if a monitor and a computer are connected by Peer to Peer and the selected network adapter meet the following conditions e Only one connected monitor is on the network The IP address is 192 168 0 X where X is between 2 254 e The subnet mask is 255 25
19. essed from Help Click page 11 start measuring and change the current luminance to within these values Appendix 1 5 16 Conditions to be displayed Setting status for black before adjusting is ina range of values that cannot be adjusted Appendix Message Causes and remedies Contrast Bright is invalid value Adjustment cannot be performed because the adjustment status for black has defects To avoid this error perform the following settings Brightness 50 R Bias 0 G Bias 0 B Bias 0 This message appears only for the PVM A series Troubleshooting The automatic color temperature adjustments do not start If the automatic color temperature adjustments cannot start because of the state of the monitor the error message Monitor not ready Please check monitor status is displayed page 14 Change the monitor s state so that it is possible to start automatic color adjustments using BKM 16R for BVM series or Control Panel for EMD PVM LMD A PVM A series Examples of the monitor s state which prevent the automatic color temperature adjustments starting BVM series only e While displaying the Select Area window e While displaying two windows During Picture Adj both Auto and Manual Adjust e During Color Temp Adj both Auto and Manual Adjust During capture saving and capture loading Reinstall of Monitor_AutoWhiteAdjustment If one of the following error messages is d
20. et to Measured Data robe Setup seis 12 Offset 7 Auto Offset More Info Probe X Rite i1 Pro 11 Pro2 Reference CRT BVM A F D v Luminance Status Calibrated Calibrate Y 100 Highlight Y 27 Lowlight 4 Contrast Bright Hold On Adjust Operations To change the offset values input the values in the text box under Offset shown in the red frame of the above picture The calculated results of Set to and Offset are displayed under Target and they are used for the adjusted target values When Measured Data is selected from the Set to list Reference can be selected Selecting the measured device from Reference automatically sets an offset value appropriate for equalizing colors on the device About limitation on adjusted target values when setting offset values The adjusted target values need to be limited even 1f the offset value is set In this case set the limitation on the values that are displayed under Target When the offset values are not set limit the values under Set to Setting the probe Place the probe in front of the monitor to be adjusted or measured Starting adjustment When you click Adjust adjustment starts and the target values are checked If they are unacceptable a warning message appears Modify the target values according to the displayed message During adjustment the following wind
21. he color temperature using this software Set the probe before you start measuring page 9 After setting the probe Start Measuring becomes active Measuring color temperature and luminance When you click Start Measuring color temperature measurement starts Operations Before measurement SE gl Monitor_AutowhiteAdjustment File Maintenance Help Setup Measured Data Network Color Temp Network Adapter Select Connection Type Peer to Peer Luminance Start Measuring LAN Monitor Selection Target Menktortist Select Model Name BVM E170 After measurement r a gl Monitor_AutowhiteAdjustment oma File Maintenance Help Setup Measured Data Network Color Temp x 0 315 Network Adapter Select L y 0 334 Connection Type Peer to Peer waj LES LAN Monitor Selection Target Monitor List EIER Model Name BVM E170 During measurement the measured values will be updated every time data is received from the probe Therefore the measurement intervals depend on the performance of the probe When measurement starts Start Measuring changes to Stop Measuring You can stop the color temperature measurement by clicking Stop Measuring During the color temperature measurement you cannot change or calibrate the probe Setting the measured value as the target value After measuring the color temperature the measured values are displayed i
22. isplayed this software cannot be automatically restored Please reinstall the software e Cannot read SYSTEM file Boot failed Please read the operation manual e Cannot read SYSTEM file Initialization failed Please read the operation manual Appendix 17 http www sony net Sony Corporation
23. ment to Exceptions for Windows Firewall in Control Panel If you are using antivirus software refer to the antivirus software manual and set permission Double click the Monitor_AutoWhiteAdjustment exe to start the installer 2 Select the language you want to use then click OKR Wait for a moment until the installation window appears 3 Follow the instructions displayed in the window to install the software Welcome to the Monitar_AutowhiteAdjustment installer Tha program instal all necessary Ale f r Monitor Ain Ales inert Ta get started did Mat When the message about the license agreement appears read it then select I accept the terms of the license agreement to continue installation 4 When the message Monitor _AutoWhiteAdjustment was successfully installed appears click Finish Monitor_AutowhiteAdjustment was To open omtor_Autoihiekcuetment dick the Start menu Al Programs Sony Mambor Ute ang then Marrtar_Autowhie jwstmeni Tick Fresh to exii the installer The installation is complete Connecting the Monitor to the Computer Two types of connections are available LAN which connects your computer and monitor via a network and peer to peer which connects your computer directly to the monitor with a LAN cable For details refer to the instruction manual of the monitor Connecting the Probe to the Computer Connect the probe to your computer by a USB
24. n the text box These values can be used as the target values If Measured Data is selected from the Set to list the measured values are set as the target values When you set this again reselect Measured Data gl Monitor_AutowhiteAdjustment Lo File Maintenance Help Setup Measured Data u A Network Color Temp x 0 309 i a I I Network Adapter Select I Lue Stes y 0 329 Connection Type Peer to Peer EET FEE Luminance i Y 143 6 Start Measuring BLAN 2 Pmmmmmmm mm Monitor Selection Target Monitor List Select Moctet Fearne ONZE Color Temp Monitor ID 1 IP Address Fe na p Set to Measured Data z Probe Setup E _ MYR f Offset Auto Offset More Info Probe X Rite it Prof i1 Pro2 v i A Reference CRT BVM A F L Status Calibrated Luminance Calibrate e Highlight YT27 Lowlight 71 Contrast Bright Hold On Adjust Luminance Y the measured value rounded to the first decimal place is displayed for the target value of Highlight If the target value of Lowlight can be specified it is automatically calculated from the target value of Highlight and input Color Temp xy the measured values are used as the target values For a PVM LMD PVM A LMD A series monitor if Y Adjustment is checked the measured value rounded to the first decimal place is displayed as the target value of Luminance Y Adjusting
25. o not disconnect the probe or communication cable before quitting this software Calibration of Probe If 11Pro i1Pro2 or CA 210 310 is selected it is necessary to calibrate it When you select the probe and the computer detects the probe connection the Calibrate button becomes active KF gl Monitor_AutowhiteAdjustment S File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Peer to Peer Luminance Y LAN Monitor Selection Target Monitor list Model Name BVM E170 i R Color Temp Monitor ID 1 c t l Gomect x 0 314 IP Address pe rap y 0 351 Set to Measured Data Probe Setup owania z Offset Auto Offset More Info Probe X Rite i1 Pro i1 Pro2 x c a Reference CRT BVM AVF D Status Not Calibrated Luminance Calibrate z Y 48 Highlight Information Y 13 Lowlight Format XYZ Picture Preset Preset D Cine W Comtast Bright told On 1 Click Calibrate A message appears if preparation for calibration is necessary Prepare for calibration according to the displayed message When calibration is successful the status becomes Calibrated on Status and the color temperature measurement becomes enabled Also when the network setting 1s completed the Adjust button becomes active and the automatic color temperature adjustments are enabled Measuring Color Temperature You can measure t
26. obe is out of the acceptable range Confirm that the probe is set correctly with the monitor to be adjusted e Perform the calibration again Possible causes include the following e The monitor setting was changed just before starting adjustment This error occurs when the input signal or Picture Preset is changed just before starting adjustment Do not switch channel change the setting or input signal just before starting adjustment The monitor does not receive commands Cancel the monitor s standby mode Turn the Menu display off if Menu is displayed then perform adjustment again This error occurs when the CA 210 or CA 310 is selected as the probe to be used while the computer does not recognize CA 210 or CA 310 Confirm the following then select the probe again The driver for CA 210 or CA 310 is installed e CA 210 or CA 310 is connected to your computer Conditions to be displayed Target value is not acceptable Default file of offset value is lost More than one application is active at the same time Mismatch of the monitor s state BVM series monitor only Cannot adjust the luminance color temperature target value Cannot adjust because the target luminance is too high Cannot adjust because the target luminance is too low Cannot adjust because the current luminance is out of range Message Causes and remedies Target Color Temperature x Target value
27. ow appears 0 311 r 0328 Highlight 106 Lwia 27 Currant 0311 i uaz Highlight 1065 Lowiighi Cancel Until adjustment completes all operations other than the cancel operation are invalid If Cancel is clicked the Adjusting Cancelled window appears and the automatic color temperature adjustment is canceled When the automatic color temperature adjustments complete the Adjusting done window appears To Equalize Colors on Different Types of Displays If you measure the color temperatures of different types of display such as CRT LCD or OLED by using a probe and adjust the xy chroma to the same value the appearance may be different This may be caused by the different emission spectrum of each display device When you adjust the target xy chroma value by adding an offset you can set to almost the same appearance for different types of display The following offset values are standard When equalizing to BVM CRT LMD LCD LMD A LCD ao Device to be measured types BVM L LCD BVM E F PVM PVM A OLED 11 Pro xref yref xref yref 0 004 xref 0 006 11Pro2 yref 0 011 CA 310 7 xref yref 0 004 xref 0 006 yref 0 011 CA 210 xref yref 0 005 xref 0 006 yref 0 011 CS 200 xref yref 0 004 xref 0 006 yref 0 011 PM5639 06 xref yref 0 004 xref 0 001 yref 0 011 PR 655 xref yref 0 004 xref 0 006 PR 670
28. rk Adapter window is displayed Network Adapter Name IP Address 192 168 0 56 Subnet Mask Local Area Connection 256 255 2560 The displayed network adapter varies depending on your environment 2 Select the network adapter of the monitor s network Detection of the monitor starts e Only the network adapter that shows the IP address and subnet mask after typing ipconfig all in the command prompt is displayed If the network adapter that you want to use is not displayed check the network setting connection e If you change the properties of the selected network adapter such as the IP address after the settings the settings of the network adapter will be disabled In this case set the Network Adapter settings again Selecting the Monitor Selecting from the Monitor List recommended When you set the Network Adapter settings the software starts searching for a monitor that is connected to the network and the Select button in Monitor List becomes active r x gl Monitor_AutowhiteAdjustment oc mS File Maintenance Help Setup Measured Data Network Color Temp x Network Adapter Select y Connection Type Luminance Y LAN Monitor Selection Target Monitor List Model Name Not Connected Color Temp Monitor ID onitor Connect x 0313 IP Address y 0 329 Set to Measured Data X Probe Setup ma Offset FT Auto Offset More Info Probe 7 aaa Reference Status
29. tion this alert is also displayed and luminance sensor calibration stops The calibration was not performed correctly Confirm that the probe can calibrate then perform calibration again You cannot confirm the connection between this software and the monitor via a network Set the connection with the monitor again Hint This alert is displayed while performing the automatic color temperature adjustments or calibrating the luminance sensor Normally you should be able to recognize network disconnection by an invalid Adjust button or non display of the IP address Possible causes include the following 1 There is no monitor with the desired Monitor ID on the network Confirm the desired Monitor ID by clicking the Show ID button For a BVM series monitor you can also check the monitor ID by pressing and holding the SINGLE button of BKM 16R 2 The monitor is not found during the connecting process Connection timeout Confirm that the following settings of SDAP are the default MENU gt System Configuration gt Network gt Protocol Setting SDAP port number is 53862 e SDAP broadcast is permitted e SDAP publication interval is fifteen seconds 8 Firewall setting on your computer Confirm that this software s communication is permitted in the firewall setting 4 Network connection is not correct Check the network connection The value of color temperature or luminance obtained via a pr
30. ustment Acceptable target value The acceptable target value varies depending on the monitor and setting BVM series Setting item Acceptable target value Color Temp x When the input signal or the input signal setting is other than XYZ signal 0 265 to 0 350 When the input signal or the input signal setting is XYZ signal 0 300 to 0 350 Color Temp y When the input signal or the input signal setting is other than XYZ signal 0 270 to 0 360 When the input signal or the input signal setting is XYZ signal 0 310 to 0 360 Luminance When Picture Preset is set to other than Highlight Preset D Cine 40 to 150 When Picture Preset is set to Preset D Cine 20 to 72 Luminance When Picture Preset is set to other than Lowlight Preset D Cine 0 5 to 9 9 When Picture Preset is set to Preset D Cine 0 3 to 4 8 LMD PVM LMD A and PVM A series Setting item Acceptable target value LMD PVM LMD A PVM A series series series series Color Temp x 0 001 to 0 999 0 265 to 0 350 Color Temp y 0 001 to 0 999 0 270 to 0 360 20 to 300 40 to 150 20 to 300 40 to 150 Luminance In the case of a BVM series monitor the Lowlight value is automatically set depending on the Highlight input values The Lowlight value can be changed To restore the Lowlight value input the Highlight value again The Y Adjustment function works as follows for the PVM LMD PVM A and LMD A series
31. yref 0 011 K 10 xref yref 0 007 xref 0 002 yref 0 011 specbos xref yref 0 004 xref 0 006 1211 yref 0 011 When equalizing to BVM E F PVM PVM A OLED Probe Device to be measured types BVM CRT BVM L BVM E F LMD LCD LCD PVM PVM LMD A LCD A OLED 11 Pro xref 0 006 yref xref 0 006 xref yref ilPro2 0 011 yref 0 007 CA 310 xref 0 006 yref xref 0 006 0 011 yref 0 007 CA 210 xref 0 006 yref xref 0 006 0 011 yref 0 016 CS 200 3 xref 0 006 yref xref 0 006 0 011 yref 0 007 PM5639 06 xref 0 001 yref xref 0 001 0 011 yref 0 007 PR 655 xref 0 006 yref xref 0 006 PR 670 0 011 yref 0 007 K 10 xref 0 002 yref xref 0 002 0 011 yref 0 004 specbos xref 0 006 yref xref 0 006 1211 0 011 yref 0 007 When equalizing to BVM L LCD Probe i types Device to be measured BVM CRT BVM L BVM E F LMD LCD LCD PVM PVM LMD A LCD A OLED 11 Pro xref yref 0 004 xref yref xref 0 006 11Pro2 yref 0 007 CA 310 xref yref 0 004 xref 0 006 yref 0 007 CA 210 xref yref 0 005 xref 0 006 yref 0 016 CS 200 xref yref 0 004 xref 0 006 yref 0 007 PM5639 06 xref yref 0 004 xref 0 001 yref 0 007 PR 655 xref yref 0 004 xref 0 006 PR 670 yref 0 007 K 10 xref yref 0 007 xref 0 002