1. NOTE Specifications are subject to change without notice for further improvements FEATURES Powerful Dehumidifying Capability Taking advantage of refrigeration technology the dehumidifier powerfully removes partial moisture from the air to decrease the humidity level of the room and keep the indoor air dry and comfortable Lightweight Portable Design The dehumidifier is built to be compact and lightweight The casters on the bottom of the unit make it easy to move from room to room or up and down stairs Low Temperature Operation with Automatic Defrost Dehumidifier will operate in temperatures down to 36 F which is important for year round use in basements Adjustable Humidistat Different rooms in your home call for different humidity levels and our unit features 3 humidity settings The humidity level feature cycles the unit after the desired humidity level is achieved Magnetic Float Will not become stuck with mineral deposits like other mechanical floats Provides a more accurate water level reading and prevents overflow Quiet Operation When the dehumidifier operates at its lowest setting the noise level is very low at 41 decibels Large Capacity Drainage Tank The drainage tank has a maximum capacity of 12 5 pints This will reduce the frequency that you must discard the water Environmentally Friendly The dehumidifier uses the no CFC refrigerant to protect the environment and to reduce pollution Energy Efficient
2. Sa PORTABLE e DEHUMIDIFIER Users Manual For information or assistance please contact Soleus International 9451 Telstar Ave El Monte CA 91731 Tel 1 888 876 5387 www soleusair com POWERED BY GREE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE INTRODUCTION Thank you for choosing a Soleus Air Dehumidifier to provide you and your family with your home comfort needs This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new dehumidifier If properly maintained your Soleus Air Dehumidifier will give you many years of trouble free operation Please take a few moments to read the instructions thoroughly and familiarize yourself with all the operational aspects of this dehumidifier Your Soleus Air Dehumidifier removes unwanted moisture from the air to create a more comfortable environment in your home or office This unit can be conveniently moved from room to room within your home and set up in just minutes For easy reference please attach a copy of your sales slip receipt to this page along with the following information that is located on the manufacturers nameplate located on the rear panel of the unit Model Number Serial Number Date of Purchase Dealer s Name and Address KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE A This symbol denotes a caution or warning IMPORTANT SAFETY INSTRUCTIONS NOTE The WARNING instructions issued in this manu
3. The unit features low power consumption SPECIFICATIONS Power Supply 115V 60Hz Capacit 12 liters day 20 liters day ii 25 pints day 40 pints day Power Consumption 210W 400W 6 liters automatic shutdown at 5 5 liters Water Tank Capacity 12 5pints automatic shutdown at 11 5 pints Weight 27 5 lbs 30 8 lbs Dimensions WxDxH 14 5 x 10 25 x 21 e The dehumidification capacity is rated at a room temperature of 86 F with a relative humidity of 80 e f specifications are improved after this printing the product nameplate will reflect the new specifications e The operational temperature is in the range of 36 F to 98 F If the room temperature is outside of this range the unit will not operate normally SAFETY WARNINGS When using the unit please observe the following safety precautions Unplug the power supply cord before cleaning or storage Do not submerge the unit in water or place the unit close to water Do not set the unit close to heat generating devices or near flammable and dangerous materials Never put your fingers or objects into the intake or discharge ducts Do not sit or stand on the unit Discard water that has collected in the tank as required Do not operate the dehumidifier in a closed area such as inside a closet as it may cause a fire Do not use the unit near edible items objects of art or scientific materials Install drain piping at a downhill grade to make sure that condensed water ca
4. 7 2 Clean the air filter Run a vacuum cleaner lightly over the surface of the air filter to remove dirt If the air filter is exceptionally dirty wash it with warm water and a mild cleanser and dry thoroughly see Fig 8 3 Attach the air filter Insert the lower tabs of the air filter into the main unit and press the air filter in place until you hear the tabs click into place see Fig 9 Fig 8 Fig 9 Storing the Dehumidifier Properly store the unit when it is not being used for an extended period of time 1 Fold up the power supply cord and secure it to the holder 2 Discard any water left in the drainage tank and wipe away any remaining water with a cloth 3 Clean the air filter 4 Store the unit upright in its original packaging to keep it free of dust Store in a cool and dry place 11 customer service TROUBLESHOOTING If a condition listed below occurs please check the flowing items before calling The unit does not operate The dehumidifying function does not work No air is discharged Operation is noisy Has the power cord been disconnected Is the tank full indicator lamp blinking The tank is full or ina wrong position IS the temperature of the room above 95 F or below 36 F Is the air filter clogged Is the intake duct or discharge duct obstructed Is the air filter clogged Is the unit tilted or unsteady Is the air filter clogged 12 Plug the power cord into
5. e When the indoor temperature is below 59 F or above 95 F the protection device is activated The unit can only operate in HIGH power and the POWER LEVEL button is ineffective 4 Stop operation e Press the POWER button to stop dehumidification e Never stop the unit by unplugging the power cord DRAINING THE COLLECTED WATER When the drainage tank is full the tank full indicator light will turn on to alert the user and operation will stop automatically The water then needs to be emptied from the drainage tank Emptying the Drainage Tank Discard water from this point 1 Lightly press on the sides of 2 Grasp the handle and pull out 3 Discard the collected water the tank with both hands and the tank completely out pull out gently NOTE 1 Do not remove the styrofoam packing from the float on the unit The float on the unit will no longer be able to detect the water level correctly without the styrofoam packing and water may leak from the water tank This can cause electrical shock and or short circuits See Fig 1 2 If the drainage tank is dirty wash it with cold or lukewarm water Do not use detergent scouring pads chemically treated dust cloths gasoline benzene thinner or other solvents as these can scratch and damage the tank and cause water leakage 3 When replacing the drainage tank press the tank firmly into place with both hands see Fig 2 If the tank is not positioned properly the TANK F
6. in the instructions 3 Damage to the finish of the case or other appearance parts caused by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used salvaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Warranty Technical Support Customer Service Missing or Defective Parts Please Call 888 876 5387 Or Write To Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA www soleusair com 13
7. ULL sensor will be activated and the dehumidifier will not operate Check to make sure the guards are firmly attached to the tank If they are not the drainage tank will be more difficult to remove see Fig 3 4 lf the drainage tank is removed while the unit is in operation or immediately after operation has stopped water that is still in the cooling unit may drip out on the base plate Wait at least 30 minutes before removing the drainage tank If water has dripped wipe it up Fig 3 Continuous Water Drainage The unit features a continuous drainage port Using a commercial hose with an inner diameter of 15 mm the water in the drainage tank can be continuously drained out of the continuous port on the unit NOTE When setting up the equipment for continuous drainage always stop operation first and unplug the power supply plug 1 Remove the drainage tank and open the continuous drainage port Use snipers or a similar tool to cut away the continuous drainage cap in the side of the main unit see Fig 4 2 Push the hose into the continuous drainage port Pass the hose through the continuous drainage port and press it firmly onto the drainage port in the main unit The average height of drain hose should always be lower than the drainage port Drain piping should always be kept clean and clear of blockage so the condensed water can be drained out successfully See Fig 5 3 Replace the drainage tank to its original positi
8. al are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and care are factors that must be used when installing maintaining or operating the dehumidifier Failure to install maintain and or operate the equipment according to the manufacturer s instructions may result in conditions which can produce bodily injury and or property damage Contact your dealer service agent or the manufacturer about any problems or conditions you do not fully understand FOR YOUR SAFETY To reduce the risk of fire or explosion do not store or use gasoline or other flammable vapors or liquids in the vicinity of this dehumidifier ELECTRICAL SERVICE INFORMATION To reduce the risk of fire electric shock or personal injury all wiring and grounding must conform to the latest edition of Local and National Electrical Codes It is the customer s responsibility to have the wiring and fuses checked by a qualified electrician to make sure adequate electrical power is available GROUNDING INSTRUCTIONS Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a qualified electrician or servicemen if you are in doubt as to whether your appliance outlets are properly grounded This dehumidifier must be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by providing a path of least resistance fo
9. n be drained continuously If the power supply cord is damaged it must be replaced by the manufacture or a qualified service agent oes COLO ae PRODUCT DIAGRAM FRONT Handle Louver A Operation Panel Discharge port Sensor Guard Float Water Level Gauge Drainage Tank REAR Air Filter Cord Hook Cord Band Continuous Drainage Port OPERATING INSTRUCTIONS Control Panel MED HIGH QUIET Indicator Lights LA Power Indicator Light The power indicator light will turn on when the unit is plugged in regardless of whether the unit is operating or not e Tank Full Indicator Light The tank full indicator light will turn on when the drainage tank is full or positioned incorrectly If light is on empty the water out of the drainage tank and make sure the tank is positioned properly MED HIGH OUIET Power Level Indicator Lights Ea En When each light is respectively lighted it indicates that the power level is Medium High or Quiet e M MOIST Humidity Level Indicator Lights When each lamp is respectively lighted it indicates that the current setting for room humidity is 50 60 or 70 When the room humidity reaches the set level the compressor will shut off e Continuous Dehumidification Indicator Light When this light is on it indicates that the operation is in continuous mode The unit will continue dehumidifying no matter what the room humidity is Button Function
10. on Check the hose periodically to make sure it is still connected and has not been obstructed see Fig 6 4 The drain hose must always maintain a downhill grade to make sure that collected water can be drained out with the force of gravity Fig 6 Moving the Dehumidifier 1 Drain the water 2 Lift up the handle and tilt the unit back 3 Move the unit by rolling on the back casters NOTE 1 If the floor is made of a material that scratches easily or if the floor is uneven lift the unit off the floor and move it Avoid rolling the unit if the floor has shag carpeting This can damage the surface of the carpet 2 Tilt it within range of 20 to 30 degrees If you tilt the unit too far you may scratch the floor or water may leak 3 Be careful that the power supply cord does not get pinched under the unit Clearance Maintain the minimum clearance around the dehumidifier when the unit is operating as shown in the figure at right At least 8 At least 8 At least 8 10 MAINTENANCE Cleaning the Dehumidifier e To Clean the Body Wipe it with a soft damp cloth Gasoline benzene thinners scouring powder chemically treated dust cloths and detergents may damage the main unit and should not be used e To Clean the Air Filter NOTE The air filter should be cleaned approximately once every two weeks 1 Remove the air filter Press downward on the tabs on the air filter to remove it See Fig
11. r electrical current This dehumidifier is equipped with a cord having an equipment grounding conductor and 3 prong grounded plug The plug must be connected into an outlet that is properly installed and grounded in the accordance with all local codes and ordinances Do not modify the plug provided with the dehumidifier If it will no fit the outlet have a proper outlet installed by a qualified electrician If the household electrical supply does not meet specifications or if you are not sure your home has an effective ground have a qualified electrician or your local electrical utility company check it and correct any problems e All wiring must comply with local and national electrical codes and be installed by a qualified electrician If you have any questions regarding the following instructions contact a qualified electrician e Check available power supply and resolve any wiring problems BEFORE installation and operation of this unit e For your safety and protection this unit is grounded through the power cord plug when plugged into a matching wall outlet If you are not sure whether the wall outlets in your home are properly grounded please consult a qualified electrician DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS e The manufactures nameplate is located on the rear technical data specific to this unit e To avoid the possibility of personal injury always disconnect the power supply to the unit before installing and or servicing
12. s Power Button Press the button once to start operation press it again to stop operation GD Power Level Button Each time the button is pressed the power level changes in the order of Med High or Quiet e D Humidity Level Button Press to set the desired humidity level in the room which can be set in the order of 50 60 70 and continuous When the relative humidity of the room is lower then the selected humidity operation will stop automatically When the unit is turned on the default operation mode is the continuous mode In this mode operation will continue until the unit is turned off or will stop automatically when the drainage tank is full OPERATION 1 Plug the power cord into a grounded outlet e After the power cord is plugged into an outlet the power light will turn on e The fan will continuously run even if the compressor shuts off 2 Open the louver manually e Before operation starts please check and make sure the louver has been opened If the louver is closed the unit may overheat e Set the louver to the preferred angle from the 6 options When the indoor temperature is above 91 F set the louver to the maximum opening 3 Button operation modes e Press the POWER button once The unit will operate in continuous mode automatically Press the HUMIDITY LEVEL button to select a room humidity level of 50 60 or 70 e Power Level Press POWER LEVEL button to choose the desired power level
13. the outlet Discard the water in the drainage tank and then reposition the tank The protection device is activated and the unit cannot be started Clean the air filter as instructed under Cleaning the Dehumidifier Remove the obstruction from the discharge duct or intake duct Clean the air filter as instructed under Cleaning the Dehumidifier Move the unit to a stable sturdy location Clean the air filter as instructed under Cleaning the Dehumidifier WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air CFM 25E CFM 40E to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As a condition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER 1 Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship 2 Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions
Download Pdf Manuals
Related Search
manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
Airpura Industries C600 User's Manual Manual de instrucciones del Konftel 250 M1 Cabin GB User manual Bedienungsanleitung Fliesenschneider ZI-FS200 und ZI Leia o manual em PDF HIP4 Supplement to the MPC 8260 PowerQUICC II™ User`s Manual Lavod LAE-012 headphone User Manual(Ver.7.50) Operating Instructions Air Conditioner Copyright © All rights reserved.