Home
ACENet User Guide - Advanced Simulation Technology Inc.
Contents
1. 1000BASE T based connection that is provided by the ASTi system interface LOOOBASE T ACE RIU ACU2 interface 100BASE T and an approved ACENEet switch 1000BASE T However with switches that have fiber connections it is possible for a user to extend the reach of ACENet through the use of fiber ports that may be available on the switch Important ACENet fiber network connections are not sold as a product or fully tested by ASTi Each ACENet configuration will form a set of complex variables which must be tested together in their functional environment under operational conditions From experience each program has a set of unique issues and problems dependent on the equipment software and simulation deployed Therefore ASTi cannot guarantee there is zero risk of any issues arising when using fiber within ACENet ACENet Fiber Example The example described below explains how fiber networking may be used in an ACENet configu ration Server Room The Server Room has four ASTi systems There is one Cisco 6500 series switch that has various blades for different ports and connections including a Gigabit Ethernet 48 port blade s MM fiber blade s 100M Ethernet Blade etc The Cisco 6500 series switch connects via MM fiber Gigabit link to one of the Cisco 3500 series switches in the Ops rooms The Cisco 3500 series switches support the OPs rooms in this building or other buildings close by OPs Room s In this example each OPs room
2. 2 AGENOL CONNECIONS ann nee 4 3 1 Additional FAQs for ACE Software version 4 17 and later uusuuusnnnsnnnnnunnennnnnn 6 Appendix A ASTi Approved and Supported ACENet Switches 8 Appendix B ASTi Non supported ACENet Switches 9 Appendix C ACENet Fiber Overview 0c cece eee e nn nn nenn 10 ACENet Fiber Example a a ehe 10 Figure 3 Example Fiber SQUID u en ana 11 ii ASTi ACENet User Guide Ver 1 Rev G 1 0 Introduction The Audio Communications Environment Network ACENet is part of ASTi s Telestra 4 and Voisus Server product families and provides a low latency network based audio and I O distribu tion architecture for ASTi s ACE software This flexible architecture provides a highly scalable distribution network of model processing systems and remote audio and I O interface devices to address today s widely distributed and complex multi user sound and communications applica tions Powered Commercial and Mics Speaker Military Headsets PTT q RS Hand Held Terminal ACE RIU aaa ACE RIU REA ACENet Switch To ASTi Telestra 4 or Voisus Server Figure 1 ACENet Layout Copyright 2012 Advanced Simulation Technology inc 1 ASTi ACENet User Guide Ver 1 Rev G ACENEet has a wide array of features such as Remote Distribution Network based spoke and hub architecture provides digital audio and I O distribution across a wide area hundreds of f
3. achieve a working ACENet infrastructure users must adhere to certain core require ments such as e Closed Network No other traffic should be present on the ACENet network i e Only ASTi systems ACENet audio devices and ACENet compatible equipment can be con nected e Gigabit Switch All switches used in the ACENet network must be Gigabit capable Addi tionally other core switches must meet certain requirements see switch requirements below e Category 5e cable All cabling connections on the ACENet network must be Category 5e grade or higher 2 1 ACENet Switch Requirements All ACENet capable switches must adhere to the following core requirements e Gigabit Capable 1000 Mbps e OSI Layer 2 Switching device this must be a LAN Switch not a hub e Set the switch to Auto negotiate speed and duplex type e All advanced Layer 2 protocols are disabled These include but are not limited to 802 1p q spanning tree QoS etc 2 2 ACENet Cabling Requirements All ACENet capable devices must adhere to the following cabling requirements e Category 5e cable or better e 100 meters or 328 feet maximum distance e Wire according to 1000BASE T Specification Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G 3 0 Frequently Asked Questions FAQ Q Can I daisy chain switches together to extend the distance from the ASTi system to the ACENEet audio device i e ACU2 ACE RIU A Yes Multip
4. the ACENet devices which exhibit the error To fix this condition use RMS to assign a new unique number between 1 and 4096 to the device s in question Copyright 2012 Advanced Simulation Technology inc 7 ASTi ACENet User Guide Ver 1 Rev G Appendix A ASTi Approved and Supported ACENet Switches The following is a comprehensive list of ASTi tested and approved switches Switch Part Number SMC SMCGS24 SMC SMC 8508T SMC SMCGS16 SMC SMCGS8 Netgear GS105 Netgear GS108 Netgear GS605 Netgear JGS516 Netgear JGS524 Hawking HGSST Linksys EG005W Cisco Catalyst 6500 series Cisco Catalyst 4900 series Cisco Catalyst 4500 series Cisco Catalyst 3500 series Cisco Catalyst 2960 Series HP ProCurve 2800 series The SMC switches are not supported if manufactured in 2012 or later due to functionality changes 8 Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G Appendix B ASTi Non supported ACENet Switches The following is a list of known switches that are NOT approved and do not function correctly within the ACENet architecture Switch Part Number 3COM 3C16478 Packet drop outs possibly due to 802 1 Prioritization Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G Appendix C ACENet Fiber Overview ACENet natively runs over an Ethernet
5. upgrading my ACENet firmware what does this mean A Occasionally errors occur when upgrading several ACENet devices at one time Try upgrad ing the device s that failed a second time If the device is still in boot mode you do not need to do the power cycle before performing the upgrade for the second time Q While trying to upgrade the firmware on a single ACENet device it repeatedly fails This ACENEet device also happens to be the conductor denoted by the green star next to the device in RMS There are several ACENet devices attached to a Target while no project is currently run ning What is wrong A This is a known software bug that will be fixed in a later software release The temporary solu tion is to install a project on the Target that uses one or more of the connected ACENet channels Perform the firmware upgrade after installing the project Q What is a Device Number A The Device Number is a configurable parameter which determines the address space used by the device for ACENet network communications By default each device is assigned a value between and 4096 and every device on a given ACENet network segment must have a unique Device Number Q Why does my ACENEet device have a Duplicate Device Number error A A duplicate device number error occurs in the rare case when two or more ACENet devices on the network have the same device number This condition will hamper audio communications between the Target and
6. 2 1p 802 1q port priority spanning tree etc Can I use these protocols Are they required A No none of these protocols are supported In almost all cases the switch should run with its default settings Possible exceptions exist if the above or similar were to be configured by default Q Can I connect my ASTi system directly to the ACU2 ACE RIU A Yes The ASTi system can directly connect to the ACU2 ACE RIU with a crossover Category Se cable between the unit and ASTi system Q Can I connect my ACU2 and ACE RIU to the same ACENet switch A Yes The ACENet network supports mixing both ACU2s and ACE RIUs on the same switch All ASTi ACENet devices can interact on the same ACENet network Each device must have a unique device name and device number Q Can I connect more than one Telestra to the ACENet that the Crown amplifier is using A No There can not be more than one Telestra connected to the ACENet that the Crown ampli fier is using On a given ACENet network at a given time there can only be one Telestra running a layout which includes Crown amplifiers Any other configuration is not reliable and is unsup ported Copyright 2012 Advanced Simulation Technology inc 5 ASTi ACENet User Guide Ver 1 Rev G 3 1 Additional FAQs for ACE Software version 4 17 and later Important The following FAQs apply to ACE software versions 4 17 and later ACE software versions 4 17 and later work exclusively with ACENet dev
7. Advanced Simulation Technology inc 500 A Huntmar Park Drive SF Herndon Virginia 20170 U S A Tel 703 471 2104 Fax 703 471 2108 AS www asti usa com ASTi ACENet User Guide Document DOC 02 ACENet UG 1 Advanced Simulation Technology inc 500A Huntmar Park Drive Herndon Virginia 20170 USA Revision G May 2012 Product Name ACENet Document Updates e Updated to version 2 revision F for inclusion of the Voisus Server product line 11 11 11 e Added supported switches and updated VLAN FAQ 05 15 12 ASTi Telestra 4 ACENet User Guide Copyright ASTi 2010 12 Restricted Rights Use duplication or disclosure by the Government is subject to restrictions as set forth in sub paragraph c 1 i1 of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 This material may be reproduced by or for the U S Government pursuant to the copyright license under the clause at DFARS 252 227 7013 1994 ASTi 500 A Huntmar Park Drive Herndon VA 20170 Table of Contents 1 0 1Hntroduetion s ee aaa 1 Figure 1 ACEN t Layout ta Gea etait IA 1 2 0 ACENet RequirementS occocccco eee eee eee 3 2 1 ACENet Switch Requirements ccccccccccccononononccocononononcncononnnnnnnnnnannnnnnnnnnnennnnnnnrrrrrnnnnnnnns 3 2 2 ACENet Cabling Requirements u 222uunnuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnennnnnnn 3 3 0 Frequently Asked Questions FAQ zunnneennnnennnnn 4 Figure
8. e Fiber Setup Copyright 2012 Advanced Simulation Technology inc CAT5e 100 Base T CAT Se 1000 Base T i Fiber
9. eet from ASTi systems Ethernet Based Allows use of COTS network cabling and equipment ASTi qualified for easy connectivity and wide extensible distribution Highly Scalable Allows the ability to plug multiple ASTi systems and ACENet compatible equipment into a single ACENet network providing a scalable modeling and distribution capability for applications ranging from single operator to large multi operator installa tions Flexible Audio and I O ACU2s and ACE RIUs provide configurable audio serial analog and discrete I O interfaces to accommodate a wide range of peripherals such as military and commercial headsets audio amps speakers microphones recording equipment press to talk PTT units simulated communications panels Hand Held Terminals and other peripheral devices High Fidelity ACENet supports synchronized 48kHz digital audio distribution for high fidelity realistic sound and communications simulation Low Latency Closed network architecture and customized real time distribution software means extremely low transport latency which is essential for realistic simulation and elimi nation of delay related audio issues Note This document covers the details of the ACENet infrastructure and the switch requirements Please refer to our web site for specific product documentation Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G 2 0 ACENet Requirements In order to
10. has a single Cisco 3500 series switch There is a fiber connection that connects the switch back to the main Cisco 6500 series switch and ultimately the ASTi sys tem The Cisco 3500 switch also has 100M Ethernet ports for the ACE RIUs within that room In terms of data flow it creates a port based VLAN this must be transparent to the system and ACE RIUs that consists of the system s Ethernet port Cisco 6500 1000M Ethernet port Cisco 6500 Fiber port Cisco 3500 Fiber port and 1 Cisco 3500 100M Ethernet port for each ACE RIU that the system controls See the setup diagram on the following page 10 Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G Server Room ASTi System 1 ASTi System 2 ASTi System 3 6500 Series Cisco Switch Ethernet amp fiber Gigabit Ethernet Blade MM Fiber Blade ASTi System 4 en ee ee ea eae A peewee Room 1 Room 2 Room 3 1 Room 4 l l I l l l I I I I 1 l l 3500 Series i i l Cisco Switch l 1 I l l I l E I I y ERU ACE RU 1 ACE RIU 1 ACE RIU aee l A a e i ACE RIU i ACE RIU ACE RIU i ACE RIU l I I ACE RIU i ACE RIU i ACE RIU l I I l I l Room 1 ACE RIUs 3500 system 1 6500 port s are on VLAN1 Room 2 ACE RIUs 3500 system 2 6500 port s are on VLAN2 Room 3 ACE RIUs 3500 system 3 6500 port s are on VLAN3 Room 4 ACE RIUs 3500 system 4 6500 port s are on VLAN4 Figure 3 Exampl
11. ices that have firmware version 2 x Further ACE software versions 4 16 and prior require firmware version 1 x All devices sharing a local ACENet must have the same firmware version This section does not apply to Voisus Server software Q Can multiple Targets co exist on an ACENet network A Yes as long as they communicate with different sets of ACENet devices See question below for information about sharing ACENet devices If using a Crown Amplifier see section 3 0 Can I connect more than one Telestra Target to the ACENet that the Crown amplifier is using Q Can multiple Targets share channels on an ACENet device A No currently this functionality is not supported Each ACENet device e g ACU ACE RIU Crown Amplifier can only communicate with one Target at time This means that all channels on the ACENEet device will respond to a single Target only A secondary Target trying to access the channels will report a Channel Reservation Error in RMS Q Why does my ACENEet device have a Channel reservation error A A channel reservation error occurs when two separate Targets are trying to reserve or use the same channel on the ACENet device By rule the first Target to install a project that contains that ACENet channel component will exclusively reserve the channel and block all other Targets from using it So you would need to uninstall or stop the project on the first Target in order for another Target to gain acce
12. le Hops link between 2 nodes are allowed ASTi has tested ACENet with up to 6 hops i e 5 Switches between an ACU2 ACE RIU and ASTi system and noted no issues ASTi System ACENet Switch ACENet Compatible Amp 8ch ACE RIU Figure 2 ACENet Connections Q Can I use a hub instead of a Switch A No The system requires an ACENet capable switch Q Can I run at 10 or 100Mbps A No Currently this is not supported attaching 10 Mbps devices to the ACENet network may cause problems Q Do you have a list of approved switches that have been tested by ASTi A Yes Refer to Appendix A in this document 4 Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G Q I have a large switch 48 ports for example and would like to use part of that switch for ACENEet Is that feasible A Yes This configuration is acceptable as long as you are able to logically dedicate N ports for ACENEet and these ports DO NOT see traffic from the other ports This is sometimes referred to as a port based VLAN Q Can I use VLAN tagging within ACENet A No VLAN tagging is not supported However port based VLANs are supported See question immediately above Q Can I connect a router in between my ASTi system and the ACU2 ACE RIU and route ACENet packets over a WAN A No This is currently not supported Q My switch can be configured to run various advanced protocols such as 80
13. ss to that ACENet channel Q Is there a limit on the number of ACENet devices that can exist on the ACENet network A No there is not a limit on the number of ACENet devices that can be on the network with the exception being for Crown Amplifiers Up to four Crown Amplifiers can be placed on an ACENet network Furthermore a pre designated Target must communicate with ALL of the amplifiers Q What effect does the number of ACENet devices have on the Target s real time CPU loading A The number of ACENet devices a Target can see over the network will effect the overall load ing of the Targets RT CPU This is true whether or not the ACENet device is included in the proj ect that is running on the Target In other words the number of ACENet devices should be taken into account for a multi Target ACENet For project specific requirements contact ASTi for more information 6 Copyright 2012 Advanced Simulation Technology inc ASTi ACENet User Guide Ver 1 Rev G Q My ACENet device channels have valid digital analog I O but there is no audio I O What is wrong A This symptom is seen when a Target using a software version prior to 4 17 is trying to use ACENEet devices that are using firmware version 2 x There are two solutions either upgrade to ACE software version to 4 17 or greater or downgrade the ACENet firmware to 1 X ASTi strongly recommends upgrading to ACE software version 4 17 or greater Q I received an error while
Download Pdf Manuals
Related Search
Related Contents
RailLinx 900 Control System Service Manual Stryker SR capacitor and apfc system service manual www.finger string.com Manuel d`utilisation Cypress CY7C1471BV25 User's Manual Válvula de control Fisher EZ easy-e Franke Swivel Spout NEURODYN Compact Copyright © All rights reserved.