Home

SAFEPATH facility communications system

image

Contents

1. Internal battery charger and power supply Required batteries fit inside the enclosure sold separately SPB 320 requires four 12 VDC 12 AH batteries SPB 160 and SPB 80 4 require two 12 VDC 12 AH batteries Inputse Audio speaker inputs 70V or 25V field selectable Auxiliary in for alarm input signal Outputse SPB 320 has four 80 watt speaker output circuits SPB 160 has two 80 watt speaker output circuits SPB 80 4 has one 80 watt speaker output circuit and two 2 amp strobe circuits 4 amps total Supervised Audio Speaker outputs 70V or 25V field selectable all boosters must be either 70 V or 25 V Expansion output supervised 24VDC at 0 5A in alarm condition used for connecting multiple boosters DC output unsupervised for optional splitter power Each speaker circuit four for the SPB 320 two for the SPB 160 one for the SPB 80 4 can connect to speaker splitters SPB 80 4 Strobe Featurese Two 24VDC 2 amps NAC supervised synchronizable power limited Class B strobe outputs Selectable outputs Wheelock sync pass through or constant DC Trouble LED for open and short output conditions Alarm indicator LED for strobe and expansion outputs Approvals amp compliances UL Standard 864 9th edition UL Standard 1711 California State Fire Marshal CSFM New York City MEA OSHA 1910 165 ADA and UFC 04 021 01 2
2. 1 year warranty Applications Provides for additional supervised audio power for large installations Provides for additional supervised and synchronizable strobe power for large installations Can be used in new construction as well as in retrofit construction 7 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Table 7 Mechanical SPB 160 SPB 80 4 Dimensions 21 H x 16 W x 6 D wall mount Weight 36 lbs without batteries Finish Red exterior enclosure Door Lock Wheelock key lock SPB 320 Dimensions 36 H x 24 W x 6 D wall mount Weight 80 lbs without batteries Finish Red or black exterior enclosure Door Lock Wheelock key lock Table 8 Ordering Information Model Number Order Code Description SPB 320 9918 320 watt supervised audio power booster Four 80 watt circuits SPB 320E 6336 320 watt supervised audio power booster four 80 watt circuits 220 VAC input SPB 320E B 6353 320 watt supervised audio power booster four 80 watt circuits 220 VAC input black enclosure SPB 160 8989 160 watt supervised audio power booster two 80 watt circuits red enclosure SPB 160 B 9930 160 watt supervised audio power booster two 80 watt circuits black enclosure SPB 160E 6149 160 watt supervised audio power booster two 80 watt circuits 220 VAC input SPB 160E B 6150 160 watt supervised audio power booster
3. 60 Hz input E model boosters shall operate on 240 VAC 2 5A 50 60 Hz input The SPB 80 4 or SPB 160 standby current draw shall be 120mA and alarm current draw shall be 9 amps The SPB 320 consists of two SPB 160 s Each SPB 160 shall have its own power supply and battery charger The voice frequency response shall be 400 Hz 6 5 kHz 3 dB the BGM frequency response shall be 275 Hz 15 kHz 3 dB Removable quick connect disconnect terminals that accept 12 22 AWG shall be used Multiple LED s for easy indication of system diagnostic conditions shall be present on the PC board The Signal to Noise Ratio shall be gt 70 dB the dynamic range shall be gt 65 dB the Total Harmonic Distortion spec shall be 2 The booster shall be wall mountable enclosed in a steel locking enclosure with a red finish Approvals for the booster shall include UL Standard 864 9th edition UL Standard 1711 CSFM and MEA The system shall be OSHA 1910 165 ADA and UFC compliant The booster shall carry a 1 Year Warranty The SPB 80 4 amp SPB 160 enclosure dimensions are 21 H x 16 W x 6 D and the SPB 320 enclosure dimensions are 36 H x 24 W x 6 D 15 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series 4 Zone Class B Speaker Splitter The Wheelock SP4Z A B shall be UL Standard 864 9th edition California State Fire Marshal CSFM and New York City MEA approved 2 Zone Class A or 4 Zone Cl
4. SP4 RMX SPRM SPRM SPRM SP4 APS SP4 3MEM This drawing is for illustrative purposes only Legend BGM Background Music DV Digital Voice Message Expander FACP Fire Alarm Control Panel MPS Pull Station NPS Push Station Wheelock Strobe Power Supplies SP40S Supervised Multi Function Communication System SPB 80 4 80 Watt Audio Booster amp 4 Amps of Strobe Power SPB 160 160 Watt Audio Booster SPB 320 320 Watt Audio Booster SPRM Remote Microphone SP4 RMX Remote Microphone Expansion Module SP4 TZC Telephone Zone Controller SP4 APS Addressable Paging Splitter SP4Z A B Speaker Splitter SP4 SVC Supervised Volume Control Strobe Speaker Speaker Strobe Cluster Speaker DV Volume Control S SPB 80 4 SP4 APS SPB 160 SP4Z A B SP4 APS SPB 320 SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4 APS SP4 APS SPB 320 SP4 APS SP4 APS SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS V V V V 10 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SAFEPATH Addressable Paging Splitter and Telephone Zone Controller SP4 TZC SP4 APS SP4 APSe Addressable paging splitter SP4 TZC Telephone zone controller Features Allows selections of speaker zones via a telephone keypad DTMF tones One SP4 TZC controller can control up to 17 SP4 AP
5. Model Number Order Code Description SP40S 9929 Multifunction supervised paging messaging background music and emergency voice evacuation system with 24 VDC battery backup circuitry single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power and 8 standard messages batteries not included 2 required red enclosure SP40S B 9935 Same as above but with black enclosure SP40S PMK 9936 SP40S 8 message programmed message kit AM SP40S SMK 9937 SP40S after market 8 message standard message kit AM SP40S PMK 9938 SP40S after market 8 message programmed message kit AM SP40S NBT 9939 SP40S after market narrow band signal tone kit SP COA 9908 C O port adapter for the SP40S or SP40 2 recommended 24 VDC power supply is Wheelock RPS 2406 Order Code 3770 SP4Z A B 9900 Supervised 2 zone Class A or 4 zone Class B speaker audio splitter for the SP40S SP40 2 or audio boosters SPMB4Z 9907 Mounting bracket for the SP4Z A B is required when used with the audio boosters SPB 320 9918 320 watt supervised audio power booster four 80 watt circuits SPB 160 8989 160 watt supervised audio power booster two 80 watt circuits red enclosure SPB 160 B 9930 160 watt supervised audio power booster two 80 watt circuits black enclosure SPB 80 4 8988 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits red e
6. Page port input Background Music Input 13 Line Level Input 600 ohm input voltage must be less than 2 5 V peak to peak or 0 3 volts RMS Table 2 Inputse Audio Technical Specifications Switch mode Class D amplifier 40 Watts Speaker Outputs 25V or 70 7V power limited Frequency Response Voice 275 Hz 6 5 kHz BGM 100 Hz 15 kHz Meets UL Voice Evacuation Requirements of 800 2800 Hz Signal to Noise Ratio Better than 65 dB Dynamic Range Better than 65 dB Total Harmonic Distortion Less than 2 Stand by Current Draw 130 mA Alarm Current Draw 4 7 amps Table 3 SP40S Mechanical Dimensions 21 H x 16 W x 6 D wall mount Weight 36 lbs without batteries Finish Red or black exterior enclosure Door Lock Wheelock key lock 4 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Table 4 Ordering Information Model Number Order Code Description SP40S 9929 Multi Function Supervised Paging Messaging Background Music delivery and Emergency Voice Evacuation System with 24 VDC battery backup circuitry Single channel system with 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power and 8 standard messages Batteries not included 2 required Red Enclosure SP40S B 9935 Same as above but with black enclosure SP40SE 6138 Same as above but with 220 VAC input SP40SE B 6139 Same as above but with 220
7. 2 or SPB Audio Boosters OSHA 1910 165 and ADA compliant UFC 04 021 01 Applications Allows manual volume setting for telephone paging and background music for a specific speaker or speaker zone The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage Table 10 Ordering Information Model Number Order Code Description SP SVC 9926 Supervised volume control for use with the SAFEPATH 4 system SAFEPATH Remote Microphone Description Remote Microphone for use with the SAFEPATH 4 facility communications system SP40S SP40 2 or SP4 RMX Features Supervised hand held push to talk microphone Key required to enable remote microphone use Individual front panel LED indication for System Normal System Trouble and Alarm When used with the SP40S or SP40 2 the priority level is 2 the SP40S or SP40 2 on board microphone is always priority 1 Remote microphone usage disengages background music and general paging Voice frequency response 275 Hz 6 5 kHz Requires 24VDC supplied by the SP40S Audio Boosters or SP4 RMX Input current Standby 23mA Alarm 30mA Audio output level 1 05V RMS 6 wire connection to the SP40S SP40 2 or SP4 RMX Mounting plate is red and measures 8 3 4 x 5 fits into a 4 gang back box All output circuitry is Power Limited
8. 5 1 4 and shall fit into a 4 gang back box Eaton is a registered trademark All other trademarks are property of their respective owners Eaton 1000 Eaton Boulevard Cleveland OH 44122 United States Eaton com Eaton Cooper Notification 273 Branchport Ave Long Branch NJ 07740 CooperNotification com 2014 Eaton All Rights Reserved Printed in USA Publication No TD001018EN October 2014 Technical Data TD001018EN Effective October 2014 SAFEPATH series Remote Microphone Expansion Module The Wheelock SP4 RMX Remote Microphone Expansion Module shall be UL Standard 864 9th edition and California State Fire Marshal CSFM approved for use with the SAFEPATH SP40S Facility Communications System The SP4 RMX shall be a supervised outboard expansion module for use with the SAFEPATH system It shall be used to expand the number of optional supervised Remote Microphone SPRM modules up to three Two SP4 RMX Remote Microphone Expansion Modules can be connected to the SP40S or SP40 2 and shall have the capability of providing the SP40S or SP40 2 with up to six system wide All Call Remote Microphone SPRM modulesa The SP4 RMX can be programmed to provide either priority override for each SPRM module input or First In First Out First In First Out allows the active SPRM to complete its communication before another SPRM can be used All output circuitry shall be power limited Multiple on board diagnostic LED indicators shall
9. Approvals amp compliances UL Standard 864 9th edition and California State Fire Marshal CSFM UFC 04 021 01 Applications Provides for an additional microphone in a remote location Can be mounted up to 2 000 feet away from the SP40S or SP40 2 Table 11 Ordering Information Model Number Order Code Description SPRM 8996 Remote microphone for use with the SP40S SP40 2 SPB 320 SPB 160 SPB 80 4 or SP4 RMX red plate SPRM GP 9927 General paging microphone for use with the SPB 320 SPB 160 or SPB 80 4 black plate 12 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SAFEPATH 4 Remote Microphone Expansion Module SP4 RMXe Remote microphone expansion module Features The SP4 RMX will provide the capability of connecting up to 3 three Remote Microphone Stations SPRM When connected to the SP40S or SP40 2 two SP4 RMX units can be cascaded together to provide up to six remote microphones Provides for an auxiliary input for connection of an external message repeater for additional messages Can accept a line level input for broadcasting of other information When the SP4 RMX is connected to the SP40S or SP40 2 the entire system benefits from the additional microphone capability Can be connected to Audio Boosters for general non alarm paging with use of SPRM GP Multiple on board diagnostics with 3
10. be provided All wiring shall be connected to the module using quick connect disconnect wiring terminals capable of accepting 12 22 AWG wiring The SP4 RMX PCB assembly is mounted in a metal enclosure measuring 13 L x 7 5 8 W x 2 D The SP4 RMX can support each SPRM at a range up to 2000 feet a The SP4 RMX can also be connected to Audio Booster for general non alarm paging with use of SPRM GP otee N Due to continuous development of our products specifications and offerings are subject to change without notice in accordance with Eaton s Cooper Notification business standard terms and conditions otee N Refer to the products Installation Instructions for proper installation wiring procedures and any additional specifications WE ENCOURAGE AND SUPPORT NICET CERTIFICATION
11. but not limited to all appendices and amendments and the requirements of the local authority having jurisdiction AHJ 5 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Table 6 Ordering Information Model Number Order Code Description SP4Z A B 9900 Supervised 2 Zone Class A or 4 Zone Class B Speaker Audio Splitter for the SP40S SP40 2 or Audio Boosters SPMB4Z 9907 Mounting Bracket for the SP4Z A B is required when used with the Audio Boosters otee N The Speaker Splitter Mounting Bracket SPMB4Z is required when the speaker splitter is used in audio boosters The SPMB4Z can support two splitters SAFEPATH 2 Zone Class A or 4 Zone Class B Speaker Audio Splitter Description Supervised 2 zone Class A or 4 zone Class B speaker audio splitter for the SP40S SP40 2 or audio boosters Enables a single supervised speaker audio output to drive up to two Class A supervised speaker audio outputs or four Class B supervised speaker audio outputs For operation with SAFEPATH family of products SP40S SP40 2 SPB 320 SPB 160 SPB 80 4 Features Expands one zone to up to 2 zones of supervised speaker audio output in Class A Expands one zone to up to 4 zones of supervised speaker audio output in Class B Each Class A zone can accept up to 40 watts of audio Each Class B zone can accept up to 40 watts of audio Operates on either 25V or
12. supervised audio power booster with 4 Amp of Synchronized Strobe Power SPB 160 160 watt supervised audio power booster SPB 320 320 watt supervised audio power booster Live amp pre recorded message announcement Supplied with 8 pre recorded emergency messages Capable of in field recording of all messages via 1 8 line level audio input jack Preset audio levels for emergency messaging prerecorded and live mic system reverts back to a preset level regardless of the volume set for BGM or general paging On board push to talk microphone Telephone paging input disconnects BGM when in use Auxiliary input for remote microphone connection Power supply amp batteries 24 VDC 33AH max rechargeable battery back up power circuitry built in Batteries can be housed in the enclosure Up to two BAT 1212 12 volt 12 ampere hour batteries can fit in the enclosure Actual battery size required will depend on speaker and or strobe load Batteries are sold separately otee N All CAUTIONS and WARNINGS are identified by the symbol All warnings are printed in bold capital letters WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING SPECIFYING OR APPLYING THIS PRODUCT FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION INSTALLATION AND OR OPERATION OF THESE PRODUC
13. supplied for message recording A two step recording procedure is required to ensure and verify that the standard message will be permanently erased Factory programmed messages are available for custom messages Contact customer service for additional information Form is required and can be downloaded from www coopernotification com otee N For telephone paging the SP40S can connect directly into the page port of the local phone system If a page port is inaccessible the SP COA C O Port Adapter for the SP40S may be used to connect the SP40S to an unused C O port or stand alone telephone Wheelock products must be used within their published specifications and must be PROPERLY specified applied installed operated maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local state and federal codes regulations and laws Specification application installation operation maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association NFPA Underwriters Laboratories UL National Electrical Code NEC Occupational Safety and Health Administration OSHA local state county province district federal and other applicable building and fire standards guidelines regulations laws and codes including
14. to control and direct telephone paging and background music zones connected to the SAFEPATH Multi Function Facility Communication System using an RS485 connection The Addressable Paging Splitter SP4 APS shall be UL Standard 864 9th edition and California State Fire Marshal CSFM approved addressable and supervised 2 zone Class A or 4 zone Class B Speaker splitter The SP4 APS shall be used with Wheelock s SP40S or SP40 2 panel and the Audio Booster SPB 160 SPB 80 4 and SPB 320 panels Each SP4 APS shall have a single audio input capable of 25 Vrms or 70 7 Vrms at a maximum of 80 Watts The input audio power shall be distributed to the zone connections with the total not exceeding the input and no zone exceeding 40 Watts When audio boosters are connected each audio booster module shall consume 1 2 Watts from the total input power of the SP4 APS The splitter shall be mounted inside the SP40S SP40 2 or Audio Booster that it is associated with and it shall operate on 24VDC supplied by the supported module The SP4 APS shall contain 16 LED indicators used to monitor and troubleshoot the module The Telephone Zone Controller Module SP4 TZC shall be used to address the output zones on the SP4 APS The SP4 TZC shall be capable of supporting 17 SP4 APS speaker splitter modules and shall be capable of addressing all zones at once All Call a maximum of 68 separate zones 17 fixed zone groups and 9 programmed logical zone groups This shall b
15. two 80 watt circuits 220 VAC input black enclosure SPB 80 4 8988 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits red enclosure SPB 80 4 B 9931 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits black enclosure SPB 80 4E 6147 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits 220 VAC input SPB 80 4E B 6148 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits 220 VAC input black enclosure SPMB4Z 9907 Speaker splitter mounting bracket for SPB 320 SPB 160 or SPB 80 4 otee N The Speaker Splitter Mounting Bracket SPMB4Z is required when the speaker splitter is used in audio boosters The SPMB4Z can support two splitters Technical specifications 120VAC 3 8A 60 Hz input SP40SE Models 240 VAC 2 5A 50 60 Hz Standby current draw 120mA per amplifier board Alarm current draw 9 amps per amplifier board SPB 80 4 and SPB 160 have one amplifier board SPB 320 has two amplifier boards System Frequency Response Voice 400 Hz 6 5 kHz BGM 275 Hz 15 kHz Removable quick connect disconnect terminals accepts 12 22 AWG Multiple LED s for easy indication of system diagnostic conditions Sign
16. 20 requires 2 4 watts of audio power to properly operate and provide additional supervised audio output power A combination of boosters can be added together to provide for a maximum of 5 280 watts of supervised audio power Additional strobe power can be obtained via a combination of boosters The audio section of the booster shall be connected via a selectable 70V or 25V input from the Wheelock SP40S The strobe section of the booster shall be divided into two sections each supplying 2 amps of 24VDC NAC supervised synchronizable power limited Class B strobe outputs with selectable outputs offering Wheelock sync pass through or constant DC and can be activated via 8 33VDC NAC input or contact closure The internal battery charger power supply shall be capable of charging 24 VDC batteries with a maximum capacity of 33 amp hours The enclosure shall be capable of housing the correct number of 12 VDC rechargeable batteries SPB 80 4 2 SPB 160 2 SPB 320 4 with a maximum capacity of 12 amp hours Batteries with a larger capacity require an external battery enclosure s such as the Cooper Wheelock BATC or equivalent The boosters shall have power limited circuitry and be a class D amplifier with an internal battery charger and power supply The required batteries purchased separately shall fit inside the enclosure two 12VDC 12 AH for the SPB 80 4 or SPB 160 and four 12 VDC 12 AH for the SPB 320 The booster shall operate on 120VAC 3 8A 50
17. 70 7V RMS Mounts inside the enclosure of the SP40S SP40 2 or audio boosters Power and Trouble LED s Individual zone short and open LED indication Capable of detecting wiring faults Removable wiring terminals for quick connect disconnect accepting 12 22 AWG All output circuitry is Power Limited Space provided to allow for naming of the zones Powered by 24VDC supplied by the either the SP40S SP40 2 or audio boosters Standby and Alarm current at 24VDC is 15mA Approvals amp compliances UL Standard 864 9th edition and California State Fire Marshal CSFM New York City MEA UFC 04 021 01 2002 Applications Provides for expansion of one zone to up to 2 zones of supervised speaker audio output in Class A Provides for expansion of one zone to up to 4 zones of supervised speaker audio output in Class B 6 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SAFEPATH Audio Boosters Description Supervised facility communication and emergency voice evacuation audio and audio strobe power boosters UL Standard 1711 and UL Standard 864 9th edition with 24VDC battery backup capabilities Designed to provide for additional supervised audio power for live voice pre recorded messages or background music BGM Fully supervised patent pending circuitry is always in effect even during BGM The SPB 80 4 also pr
18. S splitters Telephone page input connects to stand alone telephone unused CO port page port USB connection for logical zone grouping and BGM programming supports Windows 2000 and Windows XP Up to 9 logical zones a logical zone is a user selected group of up to 5 zones individual or fixed RS 485 digital control to the SP4 APS speaker splitters Connects to the SP40S or SP40 2 via the BGM input The combination of 1 SP4 TZC controller and up to 17 SP4 APS splitters can provide Class B 4 zones per splitter Up to 68 individual zones 17 splitters 17 fixed zones groups of 4 9 logical zones Class A 2 zones per splitter Up to 34 individual zones 17 splitters 17 fixed zones groups of 2 9 logical zones SP4 TZC telephone zone controllere Connects to the SP40S or SP40 2 Auto programmable Custom user programmable for logical zones All call or selected zone s telephone paging Background music BGM zone s selectable Telephone input and background music BGM input Enclosure for the SP4 TZC controller Dimensions 13 H x 7 6 W x 2 15 D Color Black Wall mountable Requires 24 VDC model RPS 2406 SP4 APS addressable paging splittere Addressable speaker zone splitter Mounts inside the SP40S SP40 2 SPB 80 4 SPB 160 or SPB 320 Ope
19. SAFEPATH facility communications system amp expansion options Contents Description Page SP40S facility communications system 2 4 Expansion Options SAFEPATH 2 zone Class A or 4 zone Class B speaker audio splitter 5 SAFEPATH audio boosters 6 7 System diagram 8 9 SAFEPATH addressable paging splitter and telephone zone controller 10 SAFEPATH supervised volume control and remote microphone 11 Remote microphone expansion module 12 13 Architects and engineers specifications 14 16 SP40S SP4 TZC SPB 80 4 SPB 160 SPB 320 SPRM SP4Z A B SP SVC SP4 APS Technical Data TD001018EN Effective October 2014 Supersedes September 2011 SAFEPATH series 2 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SAFEPATH Fa
20. TS IN AN EMERGENCY SITUATION WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND OR OTHERS Benefits amp advantages One multi function in building communications system Background Music BGM system with patent pending supervision during BGM operation Supervised emergency fire voice evacuation system Interfaces with telephone system for general paging requirements 3 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Built in power for visual notification appliances e g strobes Expandable for larger system requirements with optional equipment Approvals amp compliances Approvals UL Standard 864 9th edition UL Standard 1711 California State Fire Marshal CSFM New York City MEA FCC Part 15 OSHA 1910 165 and ADA Compliant 1 year warranty Applications Multi use applicationse The system can function as an evacuation system an emergency messaging system a paging system an employee notification system and a background music system per NFPA 72 Fire code applicationse The system is listed under UL Standard 864 9th edition delivering supervised audio and voice messaging with strobes and notification appliance circuits NAC for visual alerting Economic OSHA applicationse The system is OSHA 1910 165 compliant and therefore it does not require reliability inspections e
21. VAC input and black enclosure BAT 1212 7390 12 volt 12 ampere hour battery SP40S PMK 9936 SP40S 8 Message Programmed Message Kit AM SP40S SMK 9937 SP40S After Market 8 Message Standard Message Kit AM SP40S PMK 9938 SP40S After Market 8 Message Programmed Message Kit AM SP40S NBT 9939 SP40S After Market Narrow Band Signal Tone Kit SP COA 9908 C O Port Adapter for the SP40S Recommended 24 VDC Power Supply is Wheelock RPS 2406 Order Code 3770 BATC R 5414 Battery Cabinet Red BATC B 5413 Battery Cabinet Black BAT 1224 7391 12 Volt 24Ampere Battery Cell Table 5 Message Capabilities Message and Priority Type of Message Voice Type Message Script 1 Fire Do not use elevators Male Three 3 rounds of code 3 horn followed by May I have your attention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do not use the elevators 2 Fire Do not use elevators Female Three 3 rounds of code 3 horn followed by May I have your attention please A fire emergency has been reported in the building While this is being verified please leave the building by the nearest exit Do not use the elevators 3 Fire Male Three 3 rounds of code 3 horn followed by May I have your attention please A fire emergency has been reported in the building While this is being verified please leave the bu
22. al to Noise Ratio gt 70 dB Dynamic Range gt 65 dB Total Harmonic Distortion 2 8 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SP40S FACP SP4 TZC BGM Telephone NPS MPS SP4 RMX SPRM SPRM SPRM SP4 APS SP4 3MEM This drawing is for illustrative purposes only Legend BGM Background Music DV Digital Voice Message Expander FACP Fire Alarm Control Panel MPS Pull Station NPS Push Station Wheelock Strobe Power Supplies SP40S Supervised Multi Function Communication System SPB 80 4 80 Watt Audio Booster amp 4 Amps of Strobe Power SPB 160 160 Watt Audio Booster SPB 320 320 Watt Audio Booster SPRM Remote Microphone SP4 RMX Remote Microphone Expansion Module SP4 TZC Telephone Zone Controller SP4 APS Addressable Paging Splitter SP4Z A B Speaker Splitter SP4 SVC Supervised Volume Control Strobe Speaker Speaker Strobe Cluster Speaker DV Volume Control S SPB 80 4 SP4 APS SPB 160 SP4Z A B SP4 APS SPB 320 SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS Wheelock Strobe Power Supply Wheelock Strobe Power Supply SP4 APS SP4 APS SPB 320 SP4 APS SP4 APS SP4 APS SP4Z A B SPB 160 SP4 APS SP4 APS V V V V 9 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SP40S FACP SP4 TZC BGM Telephone NPS MPS
23. ass B Speaker Splitter for operation with the Wheelock SP40S SP40 2 SPB 80 4 SPB 160 and SPB 320 The SP4Z A B shall enable a single supervised speaker audio output to drive up to two Class A supervised speaker audio outputs or four Class B supervised speaker audio outputs Each Class A zone shall be capable of accepting up to 40 watts and operate on either 25 or 70 7V RMS of audio input Each Class B zone shall be capable of accepting up to 40 watts of audio and operate on either 25 or 70 7V RMS of audio input The SP4Z A B shall be capable of supporting live microphone paging prerecorded emergency voice evacuation messages supervised background music and general paging announcements The SP4Z A B shall mount inside the enclosure of the SP40S SP40 2 SPB 80 4 SPB 160 and SPB 320 and shall have power and trouble LED s with individual zone short and open LED indication The SP4Z A B shall be capable of detecting wiring faults The SP4Z A B shall be powered by 24VDC which is to be supplied by the SP40S SP40 2 SPB 80 4 SPB 160 or SPB 320 Standby and Alarm current at 24VDC shall be 15mA Removable wiring terminals for quick connect disconnect accepting 12 22 AWG shall be incorporated All output circuitry shall be power limited Space shall be provided to allow for naming of the zones Addressable Paging Splitter and Telephone Zone Controller The Wheelock Addressable Paging Splitter SP4 APS and Telephone Zone Controller SP4 TZC shall be used
24. cility Communications SP40S Description The SP40S is a multifunction supervised paging messaging background music delivery and emergency voice evacuation system with 24 VDC battery backup The SP40S integrates with fire alarm systems and provides full control of building audible and visual notification appliances This single channel system is capable of delivering 40 watts of supervised high fidelity audio power and 2 amps of supervised 24 VDC synchronized strobe power It comes standard with an on board digital voice messaging system with 8 standard messages a hand held microphone power supply battery charger and numerous additional features The SAFEPATH system is expandable to 5280 watts utilizing the SPB 80 4 80 watts and 4 amps of strobe power the SPB 160 160 watts or SPB 320 320 watts supervised audio power boosters All models are available in 115 VAC or 220 VAC Features Background music Capable of broadcasting from a supplied background music BGM source Unique supervision method allows for full system supervision even during background music Line Level input for music source Frequency Response 100Hz 15KHz General paging Easily interfaces with most existing phone system page port CO port and line level signals Automatically mutes BGM Frequency Response 275 6 5kHz Night ringer or security alert connection Voice evacuation Complies to NFPA 72 requ
25. e accomplished using two digit DTMF tones from a page port an unused CO port or a stand alone telephone with a loop start circuit Also the SP4 TZC shall be able to select zones for background music The SP4 TZC has the following inputs Power USB port Background Music BGM Page Audio in The outputs are Audio out and RS485 Digital Control The basic operating parameters of the SP4 APS shall be pre programmed Customized programming shall be accomplished using a USB cable and programming computer software The SP4 TZC shall be powered using a 24VDC filtered and regulated power supply such as the Wheelock RPS 2406 The Controller Module assembly is mounted in a metal enclosure measuring 13 L x 7 5 8 W x 2 D Supervised Volume Control The Wheelock SP SVC shall be UL Standard 864 9th edition approved supervised volume control for use with the SAPEPATH Facility Communications System The SP SVC shall provide for manual volume setting for telephone paging and background music for a specific speaker or speaker zone The selected adjustment will not affect the volume setting of emergency prerecorded messages or live microphone usage The SP SVC shall be capable of handling up to 35 watts of audio power 70 7 volts or 4 watts audio power 25 volts and shall operate on either 70 7 or 25 volt input from an SP40S or Audio Booster The SP SVC shall be capable of operating in Class B or Class A wiring configurations for Class A the SP4 APS is requir
26. ed The SP SVC shall receive operating power from an Audio Booster SP40S or SP40 2 Volume adjustment settings shall be off 1 10 in 3dB increments The SP SVC shall be supplied with a stainless steel mounting plate with a black knob and require a double gang 3 1 2 deep back box for mounting Remote Microphone The Wheelock SPRM shall be UL Standard 864 9th edition and California State Fire Marshal CSFM approved Remote Microphone for use with the SAFEPATH Facility Communications System The SPRM shall be a supervised hand held push to talk microphone and a key shall be required to enable remote microphone use Same key as SP40S or SP40 2 Removable wiring terminals for quick connect disconnect accepting 12 22 AWG shall be incorporated All output circuitry shall be power limited Individual front panel LED s shall be provided for indication of System Normal System Trouble and Alarm Multiple on board diagnostic LED s shall be provided When used with the SP40S or SP40 2 the priority level shall be number two Remote microphone usage shall disengage background music and general paging Voice frequency response shall be 275 Hz 6 5 kHz 2 4 dB Power requirements shall be 24VDC and will be supplied by the SP40S or SP40 2 Input current for Standby shall be 26mA and for Alarm 38mA Audio output level shall be 1 05V RMA There shall be a 6 wire connection to the SP40S or SP40 2 The mounting plate shall be red and measure 8 3 4 x
27. eral paging The system shall be capable of delivering 40 watts of supervised audio power and 2 amps of supervised 24 VDC synchronized strobe power Minimum supervised audio power shall be 40 watts expandable to 5280 watts depending on system configuration and with additional modules and power boosters Supervised 24 VDC synchronized strobe power shall be 2 amps expandable to the requirements of the installation The system shall be capable of operating from a 120 VAC power source E models shall be capable of operating from a 240 VAC power source All models shall have a 24 VDC battery backup Standard on board system features shall include digital voice messaging a hand held push to talk microphone with override priority and a power supply battery charger The system shall be capable of interfacing with telephone systems for general paging announcements and will have night ringer capabilities Form C contacts shall be provided for system alarm and trouble conditions The system shall have 8 message contacts with contact closure activation Background music input voltage shall be capable of handling less then 2 5 V peak to peak or less then 0 3 volts The system shall have thirteen priority ordered inputs including On Board Microphone Auxiliary Input Line Level 8 Digital Messages Night Ringer Input Telephone Paging Input and Background Music Input The system shall have preset audio levels for emergency messaging prerecorded and live mic The s
28. ilding by the nearest exit 4 Emergency Female Three 3 rounds of code 3 horn followed by May I have your attention please An emergency has been reported in the building While this is being verified please leave the building by the nearest exit 5 Emergency Male Three 3 rounds of code 3 horn followed by May I have your attention please An emergency has been reported in the building While this is being verified please leave the building and report to the designated assembly area for your group 6 Weather Male Five 5 seconds of 1kHz tone followed by May I have your attention please The National Weather Service has issued a severe weather warning for our area 7 All Clear Male Five 5 seconds of 1kHz tone followed by May I have your attention please The building emergency has ended An all clear has been given Please resume normal activities 8 Test Male Five 5 seconds of 1kHz tone followed by May I have your attention please This is a test of the Wheelock evacuation system repeat this is only a test Each message can be selected to have a code 3 pre alert tone a 1kHz continuous pre alert tone or no pre alert tone Post tones are also selectable and match the pre tones for individual messages Any of the 8 messages are field programmable to record your own custom message Each message length is 30 seconds A 1 8 line level audio input jack is
29. irements Supervised NAC speaker and strobe circuits Live microphone override 8 digitally pre recorded voice messages Uses selectable pre tones for messages Strobe inputs and activation 2 Amps of 24 VDC supervised strobe power with built in Wheelock sync protocol Power limited Strobe output is selectable for control of Wheelock sync protocol or non sync operation Strobe terminals have pass through capability for Wheelock sync or non sync operation Any of the 8 messages can be dip switch selected to activate strobes Microphone activation can be dip switch selected to activate strobes Auxiliary activation Remote MIC can be dip switch selected to activate strobes 24 VDC supervised and synchronized strobe power can be expanded to meet the requirements of the installation via connecting to optional Wheelock power boosters Speaker output 40 watts of supervised audio power Speaker outputs 25V or 70 7V power limited System activation Contact closure message activation Audio processing Volume and tone controls for general paging and BGM Connectivity of optional speaker splitter modules Dual tone tone generator with Code 3 Tone and Slow Whoop for alerting of system trouble Night ringer security alerting capability Audio power can be expanded by connecting to optional audio power boosters SPB 80 4 80 watt
30. l harmonic distortion shall be less than 2 The system shall be wall mountable enclosed in a steel locking enclosure The required batteries for 40 watt systems shall fit inside the enclosure The 40 watt system shall weigh no more than 36 lbs without batteries and its dimensions shall not exceed 21 H x 16 W x 6 D Approvals for the system shall include UL Standard 864 9th edition UL Standard 1711 FCC part 15 California State Fire Marshal CSFM and New York City MEA The system shall be OSHA 1910 165 and ADA compliant 1 Year Warranty SAFEPATH 4 Audio Boosters The Wheelock SPB 320 SPB 160 and SPB 80 4 Audio Boosters shall be NFPA compliant supervised audio and supervised 24VDC synchronized strobe power boosters some models will have supervised 24VDC synchronized strobe booster capability The booster shall have 24VDC battery backup capabilities The booster shall have the capability to supervise the circuitry during playback of background music The booster shall have the capability to be inter connected to accommodate large installations with supervised audio power and also supervised and synchronized strobe power requirements Three versions of the booster shall be made available SPB 80 4 80 watts of supervised audio power and 4 amps of supervised and synchronized strobe power SPB 160 160 watts of supervised audio or SPB 320 320 watts of supervised audio Each booster shall use 1 2 watts of audio input power The SPB 3
31. nclosure SPB 80 4 B 9931 80 watt supervised audio power booster with 4 amps of supervised and synchronized strobe power two 2 amp circuits black enclosure SP4Z A B 9900 Supervised 2 zone Class A or 4 zone Class B speaker audio splitter for the SP40S SP40 2 SPB 320 SPB 160 or SPB 80 4 SPMB4Z 9907 Speaker splitter mounting bracket for SPB 320 SPB 160 or SPB 80 4 SP4Z APS 9920 Addressable paging splitter SP4 TZC 9921 Telephone zone controller TZC USB 9923 SP4 TZC programming cable SP SVC 9926 Supervised volume control for use with the SAFEPATH 4 System SPRM 8996 Remote microphone for use with the SP40S SP40 2 SPB 320 SPB 160 SPB 80 4 or SP4 RMX red plate SPRM GP 9927 General paging microphone for use with the SPB 320 SPB 160 or SPB 80 4 black plate BATC R 5414 Battery cabinet red BATC B 5413 Battery cabinet black BAT 1212 7390 12 volt 12 ampere battery cell BAT 1224 7391 12 volt 24 ampere battery cell BAT 1265 7392 12 volt 65 ampere battery cell 14 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Architects and engineers specifications SP40S Facility Communications System The system shall be a multi purpose NFPA compliant supervised general purpose audio and fire emergency evacuation system The system shall be a single channel voice evacuation system incorporating supervision during the broadcasting of background music and gen
32. ovides 4 amps of 24 VDC supervised and synchronized strobe power The SPB 320 SPB 160 and the SPB 80 4 easily connects to the Wheelock SP40S or SP40 2 Multiple SPB 320 SPB 160 and SPB 80 4 Audio Boosters can be interconnected to accommodate large installations with supervised audio power and also supervised and synchronized strobe power requirements The SPB 320 draws 2 4 watts of audio input power to properly operate and provide additional supervised audio output power The SPB 160 and the SPB 80 4 draws 1 2 watts of audio input power to properly operate and provide additional supervised audio output power A maximum of 5 280 watts of supervised audio power can be achieved Additional strobe power can be obtained via a combination of SPB 80 4 or Wheelock power supplies chargers SPB 80 4 SPB 160 SPB 320 SPB 320e 320 watt supervised audio power SPB 160e 160 watt supervised audio power booster two 80 watt circuits SPB 80 4 80 watt supervised audio power booster with 4 amps of supervised and synchronizable strobe power two 2 amp circuits Features System Activatione Audio 70V or 25V input from the SP40S or SP40 2 1 Volt input from SP4 RMX System Activatione Strobe SPB 80 4 8 33VDC NAC input connected to the strobe input Power supply amp batteries Fully supervised patent pending circuitry always in effect even during BGM Power limited circuitry Class D amplifiers
33. rates on 24 VDC supplied by the SP40S SP40 2 SPB 80 4 SPB 160 SPB 320 Handles 40 watts of supervised audio per zone UL Standard 864 9th edition listed Approvals amp compliances UFC 04 021 01 Applications Connects to the SP40S or SP40 2 to control selectable paging and background music BGM Ability to access individual or multiple speaker zones throughout the SP40S or SP40 2 system via the telephone Table 9 Ordering Information Model Number Order Code Description SP4Z APS 9920 Addressable paging splitter SP4 TZC 9921 Telephone zone controller TZC USB 9923 SP4 TZC programming cable 11 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series SAFEPATH Supervised Volume Control SP SVCe Supervised volume control Features Supervised volume control for use with UL Listed Life Safety Applications Can handle up to 35 watts of 70 7 volt audio power input Adjustment settings 0 10 in 3dB increments Operates in Class B or Class A wiring for Class A the SP4 APS is required Requires a double gang 3 1 2 deep back box or 4 square and 1 1 2 deep box with a 1 1 2 extension ring Stainless steel mounting plate with a black knob Maximum RMS current 10 0mA Approvals amp compliances UL Standard 864 and California State Fire Marshal CSFM listed for use with the SP40S SP40
34. status conditions standby alarm and trouble Operates on 24 VDC supplied by the SP40S SP40 2 SPB 80 4 SPB 160 SPB 320 The SP4 RMX is an external module Enclosure dimensions 13 H x 7 6 W x 2 15 D Color black Wall mountable Approvals amp compliances UL Standard 864 listed OSHA 1910 165 ADA and UFC 04 021 01 Applications Expands one remote microphone SPRM from the SP40S or SP40 2 to three remote microphones Two SP4 RMX modules can be cascaded together to provide up to six remote microphones from the SP40S or SP40 2 Provides for an auxiliary input for connection of an external VoiceLink message repeater for additional messages Table 12 Ordering Information Model Number Order Code Description SP4 RMX 9919 Remote microphone expansion module Table 13 Microphone and message priority levels when the SP4 RMX is used with the SP40S or SP40 2 Priority Level Device Microphones 1 SP40 on board microphone 2 SP4 RMX remote microphones 1 2 3 set priority or First In First Out 3 SP4 RMX auxiliary input only SP40S Standard Messages 4 SP40S message 1 5 SP40S message 2 6 SP40S message 3 7 SP40S message 4 8 SP40S message 5 9 SP40S message 6 10 SP40S message 7 11 SP40S message 8 13 Technical Data TD001018EN Effective October 2014 EATON www eaton com SAFEPATH series Table 14 Ordering Information
35. very two months or the required spare parts inventory Wide ranging applications from small to large facilities Can connect to pagers for private alerting of emergency trouble conditions Installation amp maintenance Multiple trouble LED indicators for quick system diagnostics Fully supervised circuitry always in effect even during BGM and general paging via patent pending technology Removable quick connect disconnect terminals for ease of wiring accepts 12 to 22 AWG Power limited circuitry with Class B or Class A wiring Class A only with use of audio splitter Surge protected circuitry Audio and strobe power limiter reset button Compatible Wheelock Products All Wheelock speaker strobes All Wheelock strobes All Wheelock speakers All cluster speakers Wheelock strobe power supply Table 1 Inputse Audio amp Activation Priority Ordered Inputs Priority Level Type of Input On Board Microphone 1 Push to Talk PTT Microphone Auxiliary 2 Remote Microphone or Remote Microphone Expander Digital Message Input 1 3 Contact Closure activation Digital Message Input 2 4 Digital Message Input 3 5 Digital Message Input 4 6 Digital Message Input 5 7 Digital Message Input 6 8 Digital Message Input 7 9 Digital Message Input 8 10 Night Ringer Input 11 Contact Closure input Telephone Paging Input 12
36. ystem shall revert back to a preset level regardless of the volume set for background music BGM or general paging Background music inputs can be an AM FM tuner cassette CD MP3 or any other remote source The system shall be supplied with 8 pre recorded messages and be capable of in field recording of customer unique messages The system shall have a dual tone tone generator with Code 3 Tone and Slow Whoop When the system is on battery power telephone page night ring and background music shall be disengaged The panel shall have power limited circuitry with an internal battery charger and power supply The power supply charger section shall be able to charge 24 VDC batteries with a maximum capacity of 33 amp hours Up to two 12 VDC 12 AH batteries may be housed in the enclosure Batteries larger than 12 Ah shall be housed in a separate enclosure such as the Cooper Wheelock BATC or equivalent Batteries shall be supplied separately The system shall have power limited circuitry and class B wiring Wiring terminal blocks will be removable and accept 22 12 AWG wire Audio output voltage shall be selectable for 25V or 70 7V The voice live microphone or recorded message frequency response shall be 275 Hz 6 5 kHz background music frequency response shall be 100 Hz 15 kHz Stand by current draw shall be 140mA Alarm current draw shall be 4 7 amps The signal to noise ratio shall be better than 65 dB dynamic range shall be better than 65 dB tota