Home
2-Port PoE Gigabit Switch Operations Guide
Contents
1. Switch Figure B 1 Mounting 00 217 05 5 5 T nies 7N y x So mM 4 832 122 7 _ UTI OUT2 IN A Tae a eG 1 063 27 0 Gigabit PoE Splitter Ir fy 5 Pm MU i 5 305 134 7 a DIMENSIONS ARE IN INCHES MILLIMETER Operations Guide 930591C CyberData Corporation Mounting Option B 2 Mounting Option Figure B 2 shows a mounting option for the 2 Port PoE Gigabit Switch Figure B 2 Mounting Mounting Option 1 Mounting Screw Pre drill two 1 8 holes Use supplied screws 2 Adhesive Peel off adhesive backing and attach to desk Operations Guide 93059 1C CyberData Corporation 9 Appendix C Typical Installation C 1 Typical Installation Figure C 1 shows a typical installation setup for the 2 Port PoE Gigabit Switch Figure C 1 Typical Installation PoE Power for Phone _ a a NAGA 802 3af or 802 3at Non PoE hts Operations Guide 93059 1C CyberData Corporation
2. CyberData The IP Endpoint Company 2 Port PoE Gigabit Switch Operations Guide Part 011187 Document Part 930591C for Firmware Version 1 0 0 CyberData Corporation 3 Justin Court Monterey CA 93940 831 373 2601 2 Port PoE Gigabit Switch Operations Guide 930591C Part 011187 COPYRIGHT NOTICE 2013 CyberData Corporation ALL RIGHTS RESERVED This manual and related materials are the copyrighted property of CyberData Corporation No part of this manual or related materials may be reproduced or transmitted in any form or by any means except for internal use by licensed customers without prior express written permission of CyberData Corporation This manual and the products software firmware and or hardware described in this manual are the property of CyberData Corporation provided under the terms of an agreement between CyberData Corporation and recipient of this manual and their use is subject to that agreement and its terms DISCLAIMER Except as expressly and specifically stated in a written agreement executed by CyberData Corporation CyberData Corporation makes no representation or warranty express or implied including any warranty or merchantability or fitness for any purpose with respect to this manual or the products software firmware and or hardware described herein and CyberData Corporation assumes no liability for damages or claims resulting from any use of this manual or such products softwa
3. Figure A 1 Standard RJ 45 Jack Connector 12345678 Table A 1 RJ 45 Connector Pin Definitions Pin Number Signal 1 _TX1 PoE Power 2 _TX1 PoE Power 3 _RX1 PoE Power 4 _TX2 5 _TX2 6 _RX1 PoE Power 7 _RX2 8 _RX2 Operations Guide 930591C CyberData Corporation The Standard Cable RJ 45 Pin Assignment A 1 The Standard Cable RJ 45 Pin Assignment The following figures shows a straight cable and a crossover cable connection Use a straight cable connection to connect switch Hub or other devices Figure A 2 Straight cable for the switch uplink MDI II port to switch Hub or other devices connection 1 TX TX 1 2 TX TX 2 3 RX RX 3 6 RX RX 6 Figure A 3 Crossover cable for switch MDI X port to switch hub or other network devices MDI X port connection 7 1 RX RX 1 2 RX RX 2 i 3 TX TX 3 6 TX TX 6 Operations Guide 930591C CyberData Corporation Appendix B Mounting B 1 Dimensions and Mounting Hole Measurements Figure B 1 shows the dimensions and mounting hole measurements for the 2 Port PoE Gigabit
4. Switch e Connect the switch from the PD port to your central Gigabit PoE Switch e Connect your IP Phone from the PSE port on the switch e Connect your computer or other networking device to any of the PSE2 ports on the switch Operations Guide 930591C CyberData Corporation 6 0 Technical Specifications Table 2 Technical Specifications Sinda IEEE802 3af IEEE802 3x IEEE802 3ab IEEE802 3az Network Media Cable TOBASE T UTP category 3 4 5 cable maximum 100m 100BASE T UTP category 5 5e cable maximum 100m 1000BASE T UTP category 5e 6 cable maximum 100m Number of Ports 3 x 10 100 1000Mbps Auto Negotiation ports LED 10 100 1000M __ Link Act indicators Other PD PSE Transfer Method Store and Forward Switching Capacity 6G MAC Address Learning Automatically learning automatically Update 8K ae Filtering and Forward 148800pps Environment Operating Temperature 0 C 40 C Storage Temperature 10 C 70 C Operating Humidity 10 90 non condensing Storage humidity 5 90 non condensing Operations Guide 930591C CyberData Corporation Appendix A The Standard RJ 45 Introduction Regarding cable making methods a cable which does not meet the standards of the sequence data will make the data transmission speed slow unstable and even be blocked Table A 1 represents the standard RJ 45 jack and the connector Figure A 1 and pin definition
5. igabit PoE Splitter Operations Guide 930591C CyberData Corporation Table 1 Powering on the 2 Port PoE Gigabit Switch LED Status Description PD Orange ON Switch has a connection from the PD port to the PSE device Power has been successfully applied OFF Connection to the PSE device is not present No power has been applied to the switch PSE Orange ON PD device such as IP phone is connected to the port and drawing power OFF PD device is not connected or no power is being drawn from the switch Link Act Green ON A valid link is established Blink Traffic is present on port OFF No link has been established 5 0 Network Connection Figure 2 Front Panel of 2 Port PoE Gigabit Switch Cyberp Data SN 707000024 motes ere See te seetegen a sar arom tevtnneernene cues cusrvatstnanevas 44s areis shuweum meemi seers menena Baroraah SOSE Dar raas moved tub above aaa JE n aa aanerer menm stra may saaan seanna aat mes wens eee ees ne CE Levrt LTEN asao im China IOS 7VOCSO I5A MAX IO ST VOC GO AA MAK Operations Guide 930591C CyberData Corporation Connect your devices computer router switch IP Phone Wireless Access Point IP Camera etc to the ports with a CAT 5 CAT 5e CAT 6 network cable Since the switch supports Auto MDI MDI X you can use either a straight through or cross over network cable Figure 3 Typical Installation of the 2 Port PoE Gigabit
6. is in full compliance with the IEEE802 3 at standard with one PD Power Device port and two PSE Power Source Equipment ports This switch can work through receiving power from another PoE switch or equipment through the PD port The PSE ports can supply power to other PoE devices 30W maximum The combined power output from both PSE ports can be up to 30W but it also depends upon the PD port supply For example if the PD supply port only delivers 15W then the two PSE ports can only deliver up to approximately 13W The switch will provide a simple economic standard for high performance GBit network applications that allows for the splitting dividing of one PoE network drop The 2 Port PoE Gigabit Switch is an ideal choice to promote the department and working group performance The switch provides simple and understandable LED indicator lights on the front panel so that you can quickly judge the working state of the switch and help to diagnose the network failure 1 1 Features e Supports PoE IEEE802 3at compliant e Supports PoE IEEE802 3af compliant e Support two power source equipment to supply external devices e Supports IEEE802 3x flow control for full duplex mode and back pressure for half duplex mode e Support ports Auto MDI MDIX e 8K entry MAC address table of the switch with auto learning and auto aging e LED indicators for monitoring PD PSE Link Activity e No external power supply design 2 0 Checklist Before you start i
7. nstalling your equipment verify that the package contains the following e The 2 Port PoE Gigabit Switch e The 2 Port PoE Gigabit Switch Quick Reference Placemat Please notify your supplier immediately if any of the previously items are missing or damaged Operations Guide 930591C CyberData Corporation 3 0 Installation 3 1 Installation Method The site where you install the switch may greatly affect its performance When installing please take the following into consideration e Install the switch in a cool dry place See technical specifications for the acceptable temperature and humidity operating ranges e Install the switch on a secure level surface that can support its weight at least 1Kg Alternatively the switch can be applied to any smooth dry surface using furnished stick on tape e Leave at least 10cm of space at the front and rear of the switch to ensure adequate ventilation 3 2 Desktop or Shelf Installation When installing the switch on a shelf on desktop make sure that the previously mentioned guidelines in Section 3 1 Installation Method are followed for adequate ventilation 4 0 Powering on the 2 Port PoE Gigabit Switch The switch is powered by your existing central POE Switch No additional power supply is required Simply plug your cable from your central POE switch into the PD port of the switch and your switch will power on for use Figure 1 Front Panel of the 2 Port PoE Gigabit Switch G
8. o installation consult local building and electrical code requirements CyberData Corporation 930591C Operations Guide Pictorial Alert Icons General Alert This pictoral alert indicates a potentially hazardous situation This alert will be followed by a hazard level heading and more specific information about the hazard GENERAL ALERT Ground This pictoral alert indicates the Earth grounding connection point Hazard Levels Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury This is limited to the most extreme situations Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury It may also alert users against unsafe practices Notice Indicates a statement of company policy that is a safety policy or protection of property The safety guidelines for the equipment in this manual do not purport to address all the safety issues of the equipment It is the responsibility of the user to establish appropriate safety ergonomic and health practices and determine the applicability of regulatory limitations prior to use Potential safety hazards are identified in this manual through the use of words Danger Warning and Caution the specific hazard type and pictorial ale
9. re firmware and or hardware CyberData Corporation reserves the right to make changes without notice to this manual and to any such product software firmware and or hardware OPEN SOURCE STATEMENT Certain software components included in CyberData products are subject to the GNU General Public License GPL and Lesser GNU General Public License LGPL open source or free software licenses Some of this Open Source Software may be owned by third parties Open Source Software is not subject to the terms and conditions of the CyberData COPYRIGHT NOTICE or software licenses Your right to copy modify and distribute any Open Source Software is determined by the terms of the GPL LGPL or third party according to who licenses that software Software or firmware developed by CyberData that is unrelated to Open Source Software is copyrighted by CyberData subject to the terms of CyberData licenses and may not be copied modified reverse engineered or otherwise altered without explicit written permission from CyberData Corporation TRADEMARK NOTICE CyberData Corporation and the CyberData Corporation logos are trademarks of CyberData Corporation Other product names trademarks and service marks may be the trademarks or registered trademarks of their respective owners Cybe r Data Technical Support The IP Endpoint Company The fastest way to get technical support for your VolP product is to submit a VolP Technical Support form a
10. rt icons CyberData Corporation 930591C Operations Guide Contents TO l stallati N a iioissmittnnsheutinanintnaddeamantinatnnintecaattaadiminaninibasaanel taatulantaantnansiabie 1 Ved e E E A A ehtethubausd cde A A A AT 1 2 0 Checklist sersceceteticee gett sceete reece cee reeteepel a E a aa 1 S O lnstallaton sanoen A R states dubaumnubboieds 2 3 1 Installation Method ooo eee eeceeeeeeeenneeeeeeeeaeeeeeeeaeeeeeeeeaeeeeeseeaaeeeeesesaeeeeeeseeaeeeeeneenaes 2 3 2 Desktop or Shelf Installation cceccccececeeeeeseeeeeneeeeeeeeeeeeeeeaeeeeaaeeeecaeeeneaeeeseaeeeeaes 2 4 0 Powering on the 2 Port PoE Gigabit Switch ccccceeeeeeeeeeeeeeeeeeeeeees 2 5 0 Network Connection ccccccccceeeeeeeeeeecceeeeeeeeeeaaeeeeeeeeeseeaeeeeeeeeenenaaaaeees 3 6 0 Technical Specifications sasacs isissisivaissnsedancesnansntasislevexsncwsdansnaxageadedeonnsnnantnaite 5 Appendix A The Standard RJ 45 Introduction 6 A 1 The Standard Cable RJ 45 Pin Assignment ccccececeeeeeeeeeeeeeeeeeees 7 Appendix B Mounting 8 B 1 Dimensions and Mounting Hole Measurements n 8 B 2 Mounting Option cries cccccactscatatatceceartiaataerecnanheancdseateaseagacncunttsduiiacdeteneaanece 9 Appendix C Typical Installation 10 Col Typical installation noiera aea aa aa 10 Operations Guide 930591C CyberData Corporation 1 0 Installation The switch is a three port Gigabit PoE Power over Ethernet Repeater Ethernet switch The switch
11. t the following website http www cyberdata net support contactsupportvoip htmi Phone 831 373 2601 Ext 333 Email support cyberdata net Fax 831 373 4193 Company and product information is at www cyberdata net CyberData Corporation 930591C Operations Guide Revision Information Revision 930591C which corresponds to design version 1 0 0 was released on April 1 2013 and has the following changes e Updates the product name to 2 Port PoE Gigabit Switch e Updates Section 2 0 Checklist Operations Guide 930591C CyberData Corporation Important Safety Instructions 10 11 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Only use attachments accessories specified by the manufacturer Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Prior t
Download Pdf Manuals
Related Search
Related Contents
Central Heating Troubleshooting Advice Hampton Bay 0258739 Instructions / Assembly 高エネルギー放射線治療システム 装置受渡ガイドライン Conceptronic Stylish Wireless 2.4Ghz Laser FX3U-4DA-ADP USER`S MANUAL TX-NR636(B) (基本操作マニュアル) GE ZV421 User's Manual 別添1(地方整備局工事成績評定実施要領) Instruções de montagem 211009 7082664 la Minerva Copyright © All rights reserved.