1. Installation Scanner Activation 14 Activate the scanner You must activate your scanner with its licence before you can use it Please follow the Scanner Activation Wizara s instructions NOTE Your supplier may have pre activated the scanner for you If the scanner is pre activated the wizard will skip both this step 14 and the following steps 15a 15b About license keys and activation codes e You will need to enter your license key that came with your scanner e Contact you dealer if you do not have a license key e Online activation will only require the license key e Manual activation will additionally require an activation code Activation codes can be obtained from your dealer or through the manufacturer s License website Follow the instructions Manual Activation below to obtain an activation code through the manufacturer s License website To activate the scanner 1 Press the Activate button to start the activation wizard 2 You are presented with 2 ways to activate the scanner Online and Manual 3 If your PC is connected to the Internet choose Online activation otherwise choose Manually 4 If you chose Online proceed to the instructions in step 15a and skip 15b If you chose Manual proceed to the instructions in step 15b skip 15a A IMPORTANT During all installation steps be sure to select YES if Windows asks you to allow the software to access the network
2. Scanner Activation Manual Manual activation e Have your license key ready before proceeding If you don t have one contact you dealer e Manual activation uses an Activation Code To produce an activation code you will need your license key and the scanner s ID which is a serial number or hardware ID The scanner s D is read off the scanner and displayed by the wizard 1 e You will need to access the internet from any device Here you can enter the 2 values license key and D to get an activation code e Follow the instructions below 1 When you choose Manual as the activation method you will be asked to enter an activation code in the empty field Click Next to obtain an activation code 2 The Manual activation wizard will display instructions Please note the actual scanner s ID hardware ID or S N serial number supplied by the wizard 1 You will need this ID to obtain the activation code in the next steps 3 Goto www Licenseactivate com 4 Inthe web interface titled License Activation enter your license key in the designated field 5 Enter the scanner s ID hardware ID or S N that is supplied by the wizard as describe in step 2 6 Note or copy the Activation Code produced by the Licenseactivate com website 2 7 Enter or paste the activation code in the manual activation wizard dialog 3 and press Next 8 The system will activate the scanner Upon completion the syst
3. User s Guide HD iFLEX Scanner Contents Table of Contents How to install new firmware 44 About This Guide 9 Trouble Shooting 45 l How are errors reported on your system 45 Overview of Scanner 3 Correcting common errors 45 Scanner Front View 3 Technical assistance 45 Scanner Rear View 4 Problems Related to Scanner Installation 46 Installation 5 Problems Related to Operation of the Scanner 47 System requirements 5 Problems Related to the Scanning Results 49 Installation Steps 5 Appendix B Important Safety Instructions 50 Turning Power ON OFF 20 Appendix C Regulations 51 Main power switch 20 FCC Regulations 51 The scanner s Self Test Procedure 20 CE Regulations 51 Scanner ready to scan 20 VCCI Regulations 51 Wake and Sleep modes 21 Toxic or Hazardous Substances or Elements 52 Sleep Wake mode options automatic power management 22 Automatic shut down after idle time 22 Loading Originals into the Scanner 23 Load face down align at the scanner s left side 23 Setting the input size 25 Scanning 26 Software applications for scanning 26 Running applications from the scanner panel 26 Nextimage Scan Copy button 26 Batch scanning 26 Scanning Thick Media 27 Monitoring your scanner with WIDEsystem 27 Maintenance 29 About scanner maintenance 29 Overview key maintenance points 29 Cleaning the scan area glass 30 Calibration 33 Replacing Scanner Parts 36 Replacing the White Background Platen 37 Replacing the Dust Filters 41
4. B amp W calibration and Color calibration Before starting calibration please make sure the glass plate is dean Insert the Calibration Sheet in the scanner and choose a calibration procedure as depicted below A Maintenance Calibration Insert the calibration sheet During the process the wizard will ask you to insert the Calibration Sheet that came with your scanner The sheet s printed side must be inserted face down on the glass Click the wizard s Next button to continue Calibration Bone program calibrates the scanner The program works in steps to analyze and correct the status of the sensors calibrate black and white values and calibrate color The calibration sheet will be rescanned a number of times as the program processes data Let the program complete the calibration steps you requested The wizard will tell you when the process is finished After Calibration 1 Remove the Scanner Calibration Sheet from the scanner 2 Return the Scanner Calibration Sheet to its protective cover and then place it in the storage folder 3 Store the folder in a dry place and out of direct light Maintenance 36 Replacing Scanner Parts This section describes how to replace scanner parts that are liable to wear down over long term use Changing parts will renew your scanner and reestablish optimal results WIDEsystem monitors scanner usage and will warn you when it is t
5. Ea Activation Wizard The scanner needs to be activated The scanner XX200x Not Activated USB must be activated within 50 hours The scanner with serial number 67GA 1500 10 1L needs to be activated within 49 hour s Choose on how to proceed ae Installation Scanner Activation Online Online activation Online activation is very easy You only need your license key When you choose Online as the activation method the dialog shown on the top right appears 1 Enter you license key in the designated field 2 The key will be authenticated online right after it is entered and if valid a green tick will appear as shown in the dialog shown on the right middle Press the Activate button to continue The Success dialog will indicate successful activation Please enter the license key for the scanner with serial number 67GA 15000010 The license key is a string of 20 characters starting with AB License key If you do not have a license key then dick on Cancel and contact your local dealer for help Please fill in m Please enter the license key for the scanner with serial number 67GA1500Q01Q The license key is a string of 20 characters starting with AB License key ABPQ 2JAK ET3H TUJA AAAC v7 If you do not have a license key then dick on Cancel and contact your local dealer for help Scanner is restarting Please wait Installation
6. You turn the scanner OFF and ON sleep wake up by pressing the power key on the panel The scanner skips its init sequence and is ready to scan sooner than with Main Power OFF to ON Convenience When OFF LED is yellow the scanner can be powered up Wake up easily by pressing the power key thereby indicating you wish to scan Save energy Sleep mode runs at low power values Turning the Scanner ON OFF Sleep Wake mode options automatic power management Automatic power management lets you schedule your scanner s up time optimally and helps save energy You can set the scanner for automatic power OFF Sleep and power ON Wake up Automatic power management functionality is set and controlled through your WIDEsystem software Your scanner supports one automatic power function 1 Enter Sleep mode automatically Automatic shut down after idle time In order to use automatic power management functionality the scanner Main Power switch at the scanner s back must be turned ON Automatic shut down after idle time On delivery the scanner is set for automatic entry into sleep mode after a preset default idle time i e the length of time the scanner is not active You can prolong or shorten the idle time value to match your normal workflow Ei NOTE You will be prompted to change the idle time during installation If you have done this you can omit this step unless you wish to reset To change set the sleep mode optio
7. equipment CE Regulations EU Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures VCCI Regulations Japan This equipment has been tested and found to comply with the limits for a Class A product according to Agreement of VCCI 2008 CISPR 22 C Regulations Toxic or Hazardous Substances or Elements Part Toxic or hazardous Substances and Elements 4 4 4 mi BCR Name Mercury Cadmium Hexavalent Polybrominated Polybrominated BD AA Hg Cd Chromium biphenyls diphenyl ethers JK EA Cr VI PBB PBDE Fluorescent Lamp RICH O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 KRZA RA EAE ZAE A BA Bd FE SU T1 1363 2006 tari BLE AY BR a BERLE o X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 FON IAA BEA FY BLD ETA BE A FE SP cB h SJ T1 1363 2006 tn EE REER Enterprises may further provide in this box technical explanation for marking X based on their actual conditions A AY Fe IEE ch AR He SK Bs tS oe ERRA XP AY BTR RET HE 2 A
8. lly performance of your scanner recognize when cleaning the scanner or changing parts Instructions follow in the next sections 1 Cleaning Keep your scanner clean the next section describes how to thoroughly clean the internal scan area How often you need to clean the scanner will depend on how often and the types of media you scan If your work primarily involves scanning newspapers and old blueprints you may need to clean more often than users who only scan brochures and new drawings Be sure to clean the scanner when results are not optimal Particles of dust in the scan area can often be the cause of streaks in the end result See more under the section Cleaning the scan area White background Replacement Glass Plate Cleaning 2 Calibration and camera alignment Scanner Calibration is easy to perform and most of it is completely automatic Scanner calibration includes camera alignment and calibration of B amp W and color parameters To run you insert a Calibration Sheet and start the Scanner Maintenance program Be sure to calibrate if your output is not optimal Make sure the scanner is clean before calibrating See more under the section Calibration 3 Replacing worn parts Dust fit A i ern This should be carried out when you get a warning on your screen or Replacement when a worn part affects your results Replaceable parts are a the white background platen b The air vent s dust filters See more und
9. 3 Set the size manually for irregular sizes To measure your document use the scanner s ruler on the edge of the scanning area Enter your width measurement in the width setting field in your application s input size setup dialog You can measure and set a ength value or choose automatic length detection Scanning Scanning Software applications for scanning Your scanner is controlled through scan copy or imaging software installed on your PC Optimal full featured scanning functionality is obtainable through scan and copy software specifically developed for compatibility with your scanner model See the scanner manufacturer s website for information on scanner software and compatible third party applications Simple scanning functionality Many common imaging applications support TWAIN and WIA interfacing and will thereby support simple scanning tasks through a limited range of settings and control options Running applications from the scanner panel Normally you would control the scanner from your PC through your scan software user interface However your scanner also supports one touch buttons that enable you to trigger your software and actions from the scanner panel When a button is pressed a scan is initiated and the result is loaded into the application triggered You configure your one touch buttons through WIDEsystem and your compatible scanning software Please refer to the on line help in these applications for inst
10. A damaged calibration sheet can also cause streaks Obtain a new sheet and recalibrate the scanner B Safety Instructions Appendix B Important Safety Instructions M rece all of these instructions and save them for later use Follow all warnings and instructions marked on the scanner A Do not place the scanner on an unstable surface stand cart or table Serious damage can be caused if the unit falls B For cleaning do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning C Before cleaning or replacing any user replaceable parts be sure to turn the scanner power off and disconnect the power plug D The scanner should be operated from the power source type indicated on the marking label If you are unsure of the type of power available consult your dealer or local power company E The scanner is intended for use on IT TT and TN power distribution systems and is equipped with a three wire grounding type plug This plug will fit only into a grounding type power outlet This is a safety feature which relies on building installation If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat or ignore the purpose of the grounding type plug F Do not allow anything to rest on the power cord Do not locate the scanner where persons will walk on the cord G If an extension cord is used with the scanner make sure that the total ampere ratings of the p
11. Downloading New Firmware 44 What is Firmware 44 When do I need new firmware 44 How to identify the firmware version running in the scanner 44 About This Gui About This Guide This guide explains how to operate and maintain your wide format scanner This user s guide covers Model HD iFLEX 18 A2 wide format flatbed scanner The guide assumes basic knowledge of your computer and operating system and does not repeat material from their documentation Be sure to refer to 1 The Installation section describes correct installation of your scanner drivers 2 The readme htm file in the ws folder on the WiDEsystem TOOLS CD ROM Contains the most current installation and OS compatibility issues 3 WIDEsystem TOOLS Help After installing your drivers open WIDEsystem and press F1 Contains information on using the WIDEsystem software A IMPORTANT Be sure to use the WIDEsystem TOOLS CD ROM that came with your scanner or a newer version Out of date versions of WIDEsystem software may not detect your scanner model Bf nore Windows Compatibility Your scanner and drivers are tested and developed to support the most current active Microsoft Windows version OS systems Drivers and interface support in regard to specific Windows versions will follow the Microsoft Support Lifecycle Policy The compatibility specifications can therefore change accordingly The most current OS compatibility specifications and dr
12. Optimal speed according to specifications will require you connect the scanner to a gigabit connection To enable gigabit interfacing ke 1 Disconnect the USB connection to your PC 2 Connect an approved gigabit cable to the scanner Ethernet interface socket at the scanner s back 3 Connect the other end of the gigabit cable to your LAN Scanner My Scanner zj 4 Open WIDEsystem if not already open double click the WIDEsystem icon in the system tray Status Info Timer One Touch Network License 5 Press the Refresh Scanner List button Scannermode Ready 6 The system will automatically include and share the scanner on the network and enable scanning at Original Ready Original has been loaded gigabit speeds Scanner Messages No messages Maintenance Messages B nore Use only an approved gigabit cable Full specified performance cannot be guaranteed with other No maintenance required cables or normal LAN cables Bf nore WIDEsystem will provide a warning if you are running on a gigabit scanner without a gigabit connection Installation Set up USB connected scanner for sharing on the network Set USB scanner for sharing on the network Optional You can enable other PCs on the LAN to use the USB connected scanner This is called Sharing After activating the scanner You can set it up as a shared scanner through WIDEsystem B nore These instruction
13. and links its processors with the PC applications running the scanner When do I need new firmware Your scanner is shipped with the latest firmware available You can afterwards upgrade your original firmware with newer firmware and continue to do so as they are released Firmware upgrades can be downloaded from your manufacture s website or obtained through your dealer Upgrade your firmware when 1 One or more new features are released or other improvements are made to the scanner though its firmware 2 Anerror is discovered in the firmware version you have in the scanner and your manufacturer recommends installation of new firmware in which the error is corrected Bf NOTE Your manufacture s website specifies improvements for every new firmware release 44 How to identify the firmware version running in the scanner 1 Start WIDEsystem double click on the system tray s WIDEsystem Icon lt lt Select the Info tab The Info tab displays useful data about your scanner firmware Firmware release Upgradeable firmware version Firmware download time The date time the current firmware was downloaded Che You can upgrade your firmware if the Firmware Release number is lower than the newest firmware version number on your manufacture s website How to install new firmware New firmware is installed by opening the firmware exe file The firmware exe file must first reside on your machine Select the S
14. ave target or Save Link option if downloading from the web To install the firmware file on your scanner 1 Go to your manufacture s website and locate the new firmware for your scanner Download save the firmware exe file in a folder on your machine Double click the exe file to start the installation wizard Follow the wizard s instructions on your screen Installation can take up to 1 minute depending on the scanner model and firmware version The WIDEsystem scanner icon on your system tray blinks red during the process oo E NOTE Update WIDEsystem When upgrading firmware always update WIDEsystem to the latest version WIDEsystem is available on your manufacturers website Trouble Shooting Trouble Shooting This section describes trouble shooting procedures for the most common issues that can arise with your scanner Please look for a problem description that matches your actual situation If found perform the recommended trouble shooting procedures before requesting a service call How are errors reported on your system The scanner panel s Error Indicator will blink when the scanner detects an error WIDEsystem will report the nature of the error on your screen Correcting common errors 1 The actual nature and cause of the error may be reported immediately through a message on your screen If not open WIDEsystem double click the WIDEsystem icon on your system tray and select the Status tab to vi
15. e If convenient you can place the backend of See the Safety Instructions at the end of this operator s guide the scanner against a wall The lid will not open all the way back and stops at an approximate 650 angle lt is very important to follow the instructions below to ensure the scanner is setup with optimal stability and without tension on the scanner s frame Failure to do so can produce poor scanning results and cause damage to the scanner device over time Installation 2 Adjust the scanner s feet for sturdy A IMPORTANT DO NOT YET CONNECT THE SCANNER TO POWER OR PC placement The scanner rests on feet placed at the bottom of the scanner There are 3 fixed feet and 2 adjustable feet total of 5 feet See the instructions below for feet adjustment 1 The two outer feet closest to the operator s panel side are adjustable The middle foot on the same side and the two feet on the other side are fixed 2 The 2 adjustable feet should be positioned tightened all the way up when setting up the scanner on its new surface They are delivered in that position from the manufacturer 3 The 2 adjustable feet in their original position as described in step 2 are slightly shorter than the 3 fixed feet Therefore the scanner will at first rest only on the 3 fixed feet 1 on the operator panel side and 2 on the opposite side 4 Use a screwdriver or an alternative long slim object to access and rotate the 2 adjustab
16. e If the scanner does not operate normally when operating instructions are followed then adjust only those controls covered by the instructions in this manual Improper adjustment of controls other than those mentioned in this manual may result in permanent damage and will at best require extensive work by a qualified technician to restore this product to its normal operation e If the scanner has been dropped or the cabinet has been damaged e If the scanner exhibits a distinct change in performance indicating a need for service C Regulations Appendix C Regulations FCC Regulations USA NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Pursuant to Part 15 21 of the FCC Rules any changes or modifications not expressly approved by the manufacturer may cause harmful interference and void the use s authority to operate the
17. e PC verify that WIDEsystem is running the WIDEsystem icon should be visible in your system tray 2 If WIDEsystem is not running locate the WIDEsystem entry under your Programs menu and start it manually 3 Make sure the USB cable is connected to the scanner as instructed in a previous step 4 Connect the A connector end flat end to a USB port on your computer Bf nore It is recommended to use an available USB port on the back of the PC Using USB ports on the front can affect performance on some PC models Scanner installation a The Installation Wizard starts up 1 The driver will detect the scanner and start the scanner installation wizard 2 On first time installations the WIDEsystem Scanner Installation Wizard should start after 20 seconds 3 If the installation wizard does not start up perform one or more of the following a Unplug and reinsert the USB connections to scanner and PC b Ensure the USB cable is connected firmly at both ends c Try a different USB port on the PC d Make sure the USB is inserted into the port marked for USB at the back of the scanner and not for example the Ethernet port Welcome to the Scanner Installation Wizard This wizard will help you to register your scanner on your PC Do not run Installation wizard automatically To continue click Next Installation Scanner installation 12 Windows installs the scanner 1 Click Next a
18. em will display the success message The scanner with serial number 67G4 1500Q0 10 can be activated manually with an activation code The activatan code starts with the letters AC and is 36 characters long Code eager Scanner Activation Wizar If you do not have a code dick on Next a Manual activation of the scanner with serial number 67GA 15009010 Please do the following 1 If you do not have a license key then contact your dealer to obtain one 2 From an internet connected device visit www Licenseactivate com 3 Enter your license key and the following HardWare ID AADB 4AWB CSAB WAAY SABF EANA on 4 Note the resulting activation code 5 Enter the activation code the next time the wizard is started eax _ pnnt _ save __close _ License Activation Please complete the form below License Activation Activation information Y Activation Code Generated Activation Code information Serial Number AADB 4AWB CSAB WAAY SABF EANA a Activation Code ACSM8P JZM6NF V9P2X5 DRPJUS 2T3IJ3L ERLFKQ Scanner Activation Wizard The scanner with serial number 67GA 15000010 can be activated manually with an activation code The activation code starts with the letters AC and is 36 characters long m z 3 i 2 Scanner Activation Wizard il Code ACSM3P JZMGNF V9P 2X5 DRP JUS ZT3JA ERLFKQ W Vane 3 If you do not have a code click o
19. er the section Replacing scanner parts Maintenance Cleaning the scan area glass Follow the steps below for thoroughly cleaning the scan area Be sure to clean the scan area when results are not optimal Even small dust particles in the scan area can cause streaks in your scanned image To clean the scan area You need to open the lid to access and clean the glass Follow the instructions below 30 A Caution do not use abrasives acetone benzene or fluids that contain these chemicals Do not spray liquids directly onto the scanner glass plate or anywhere else in the scanner A Caution Before cleaning the scan area be sure to turn the scanner power off and disconnect the power plug Cleaning the scan area he Turn scanner power off and disconnect 1 Press the main power switch scanner back to OFF 2 Disconnect the power plug Maintenance Cleaning the scan area 2 Open the scanner lid Pull back the scanner lid to expose the scan area glass plate Cleaning the scan area Clean the glass 1 Clean the glass with a lint free cloth and a mild streak free glass cleaner 2 Dry the glass completely using a separate clean dry lint free cloth like the one provided with the maintenance kit 3 Close the scanning area lid when finished Maintenance Cleaning the scan area ae 4a Cover when not in use Cover the scanner with its plastic dust cover when n
20. ew additional information about the error 2 The information on your screen may include instructions and actions to remedy the error Follow the instructions on your screen 3 Look for a description of the error and remedy in this users guide s trouble shooting section Follow the instructions provided Technical assistance Error defected Error indicator blinks In some cases you may need technical assistance You should contact your service provider if one or more of the following cases is true a the error cannot be remedied through the action suggested on your PC screen b the error and its remedy is not described in this users guide c the system fails to report the error on your screen Before calling technical assistance prepare the following 4 Write down your scanner model and serial number The serial number is printed on a label on the back of the scanner 5 Write down your Firmware version See the section How to identify the firmware version running in the scanner f nore Your manufacture s website contains service provider contact information This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A conforme la norme SE co LNU OR NTO UIO UO IY O IT NO NMB 003 du Canada 51DAYMnnnROC This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions N 1 This device
21. he system fails to report the error on your screen Need to contact Technical assistance In order to get the best and fastest solution to your problem you should prepare as much information as possible before calling your service provider for technical assistance Your manufacture s website contains service provider contact information See instructions above Trouble Shooting Error message Correction of Camera X Your scanner is continuously monitoring its cameras This error message often appears when the internal glass plate or failed white background platen is dirty or smudged Clean the scanning area reboot the scanner and then complete the maintenance steps as described in the section Maintenance in this guide If the problem persists after cleaning the scanner area The problem could be caused by a loose object in the optical path Remove any torn pieces of paper or other loose objects from the scanning area Even the smallest loose objects will disturb the scanner s adjustment function Summon your technical service provider if the problem persists Error message Unable to Adjust Camera _ There could be a loose object in the optical path Remove any torn pieces of paper or other loose objects from the scanning area Even the smallest loose objects will disturb the scanner s adjustment function If the problem persists after controlling for loose objects in the optical path the problem is often caused by an unclean
22. ime for a replacement The following parts can be replaced 1 The White Pressure background platen 2 The dust filters Br NOTE Regarding WIDEsystem WARNING FLAG White background platen replacement After receiving a warning by WIDEsystem and replacing the part be sure to reset the part replacement warning flag through WIDEsystem s Status tab Bf NOTE Regarding RECALIBRATION White background platen Replacing this part will change conditions in the scan area Therefore it is recommended to recalibrate right after changing the White background platen and cleaning the glass Start WIDEsystem and select Calibrate A Important Safety Instruction Before replacing any parts be sure to turn the scanner power off and disconnect the power plug s Eu Ta 3 Maintenance 37 Replacing the White Background Platen Your white background platen can become worn and discolored after long periods of use and in such cases replacement with a fresh white background platen is recommended WIDEsystem monitors scanner usage and will warn you when it is time for a replacement Replacing the white background platen a Turn scanner power off and disconnect 1 Press the main power switch scanner back to OFF 2 Disconnect the power plug Replacing the white background platen 2 Open the scanner lid Pull back the scanner lid to expose the scan area glass plate Maintenance Replacing the wh
23. ite background platen 3 Locate the white background platen The white background platen is attached to the lid s underside It is constructed as two layers upper layer and lower layer The lower layer faces the glass The upper layer is attached to the bottom side of the lid with Velcro at its corners and edges White Background Platen 2 layers Maintenance Replacing the white background platen Remove the old white background platen Use both hands to place your fingers between the bottom side of the lid and the top edge of the upper layer Pull the platen free Replacing the white background platen g Place the new white background platen on the glass Place the new white background platen on the glass plate with its Velcro corners facing up Align the new white background platen on the glass by making sure there is an equal amount of space around all four edges of the lower layer the layer resting on the glass Maintenance Replacing the white background platen 6 Gently close the lid Press the lid firmly at all its corners and edges to ensure contact between the lid s Velcro and the white background platen s Velcro Replacing the white background platen kis Press on the white background platen Make sure your hands are clean Open the lid and press firmly on the new white background platen corners and edges to make sure the Velcro is properly in contact i
24. ivers will be available on your manufacturer s website Overview of Scanner Overview of Scanner Scanner Front View Parts you need to recognize when installing and using the scanner Scanner lid 7 Operator s panel contex EED iLL Scan area Glass plate Power button and indicator Error indicator ee One touch buttons Scan Application Copy Application ee Email Application Nextimage Scan Copy button Overview of Scanner Scanner Rear View Parts you need to recognize when installing and using the scanner Main Power switch and Power socket Interface connections USB Gigabit Installation Installation System requirements e PC or supported workstation Recommended requirements 1 6GHz Dual Core processor or better 2 GB RAM 5 GB of available hard drive space USB 2 0 interface e Compatible Windows operating system View the ws readme htm file on the WIDEsystem TOOLS CD ROM e The WIDEsystem TOOLS CD supplied with your scanner e Scanning software or compatible third party software e Grounded power outlet e PC with USB port or enabled Gigabit port Installation Steps To get your scanner up and running follow the steps below in their written order a A IMPORTANT DO NOT YET CONNECT THE SCANNER TO Set up the scan station mp Ce Your wide format flatbed scanner should be placed on a stable level and completely flat plane surface such as a sturdy tabl
25. le feet until they touch the surface so a 2 adjustable feet all 5 feet are in contact with it re ae Original position must be all the way up 5 If the scanner is moved the 2 adjustable feet must be ouenest IEE retightened to their original shortest position and the steps above must be repeated Installation Installing scanner software WIDEsystem drivers and Scan Copy software Install WIDEsystem and scan copy software on your PC A IMPORTANT WIDEsystem contains your essential scanner drivers You must install WIDEsystem before you connect the scanner or install any scanner software applications 1 Insert the WIDEsystem TOOLS CD ROM into your PC Normally the setup program interface will start automatically If it does not locate the setup exe file on the CD and start it manually 2 Follow the instructions on your screen to install the WIDEsystem software and scanner drivers Reboot the PC when asked to do so to complete installation 3 Remove the CD when done with installation To verify correct installation of WIDEsystem the WIDEsystem icon will be visible in your system tray After installing WIDEsystem install the Scan amp Copy software you will be using with the scanner Select the required installation options for the Scan amp Copy software from the WIDEsystem TOOLS CD or from a third party installation CD A IMPORTANT During all installation steps be sure to select YES if Window
26. ls into the Scanner Load face down align at the scanner s left side al Open the scanner lid Pull back the scanner lid to expose the scan area glass plate Place your document Place your document face down on the glass plate Loading 8 sion and center Align the document edges against the alignment guide bar at the scanner s left side for a straight scan Align the document middle with the center arrow marking on the alignment bar You can use the standard size markings to position the original and determine its standard size Close the lid Carefully close the lid over the document without disturbing its position and alignment Loading Setting the input size The Input size defines the scan area You enter the input size in your application s input size dialogs NOTE The availability of the Input size options described below will depend on your scan copy software and its level of compatibility with the scanner model 3 ways to set find and set the input size 1 Use automatic size detection The scanner will detect the edges of the document and calculate the input size for you 2 Seta standard size common standard sizes are marked on the left side of the scan area at the scanner alignment bar Use these markings to determine which standard size matches the original and then select that size in the application s input size dialog
27. may not cause harmful interference and C US LISTED z AA12 2 this device must accept any interference received including interference that may cause undesired operation EH HANK HARP ih CEE WRAT ARE aF ERPF SY BE REA et Se ee Fe TORNS TOZAMRMTER TT CORMER ERATOR SEMRGRESISROT CAUSE TORA EAAS CORAM PSkSMRANSTEMHOES VOCHA Laite on llitava suojaadoituskosettimilla varustettuun pistorasiaan Apparatet m tilkoples jordat stikkontakt Apparaten skal anslutas till jordat uttag FREQUENCY RANGE 50 60Hz 39368 AC VOLTAGE Set AB CURRENT MAX 2A contex CONSUMO DE ENERGIA POR UNIDAD DE TIEMPO EN OPERACI N DEL E Svanevang 2 0K3450 Aleroed Denmark CONSUMO DE ENERGIA EN ESPERA POR UNIDAD DE TIEMPO DEL EQUIPO Wh Made in Denmark SEER MH AROE Serial Number Trouble Shooting 46 Problems Related to Scanner Installation Your interface is not enabled on the PC or set up correctly Control that the Windows device manager lists the interface Unknown device is found message option and that its drivers function correctly WIDEsystem drivers were not installed before connecting the scanner Shut down the scanner and PC unplug power and USB connections and restart the installation from step 1 as described in the installation section of this guide If you continued installation before installing WIDEsystem see the troubleshooting instructions below Loose interface connection on both ends unplug and then fir
28. mly plug in the interface cable System needs rebooting shut down the scanner and PC unplug power and USB connections Then plug in the USB connections and turn on the PC When Windows is loaded plug in the scanner power and turn on the scanner main power switch If you connected and tried to install the scanner before installing WIDEsystem the unknown device found message will appear No functional drivers found yellow error If you ignored this and continued to step through the dialogs from there the scanner will be entered on the system as a new icon on scanner in Device Manager device without functional drivers If this is the case the scanner will be displayed in the Windows Device Manager with a yellow error icon The scanner entry must be removed from the Device manager before re installing correctly In the Device Manager remove the scanner entry Shut down the PC shut down and unplug the scanner disconnect the scanner from the PC Perform the installation from step 1 as described in the installation section of this guide Be sure to install WIDEsystem before connecting the scanner The scanner may be in sleep mode Press the power button to wake up the scanner WIDEsystem does not detect the scanner The WIDEsystem driver version installed on your PC is older than your scanner model Install the WIDEsystem drivers from the WIDEsystem TOOLS CD ROM that came with your scanner If not available download the newest version from y
29. n Next Success j Please fill in Scanner is restarting Please wait Installation Scanner Installation Change network name aner Inctallatncr Ween 16 Change the scanner s network name optional The scanner is identified on the network by the following name Wor This step only appears with licensed Ethernet supported scanners as You may change the name here detected during activation IFLEX_6 G41200000 You may wish to change the default name of the scanner to comply with your organization Click Next when done Installation Scanner Installation Installation complete The scanner has been installed correctly when you see this message For using the optimal Gigabyte interface proceed to the steps for enabling gigabyte on the scanner plus sharing it on the network If using only the USB interface you can also choose to share the scanner on the network Instructions for sharing USB scanners on the network follow below l Scanner Installation Wizard Scanner Installation completed The scanner My scanner USB has been installed successfully You have activated a scanner model that includes the Ethemet feature To benefit from this feature you May now connect the scanner with an Ethemet cable Please click on Finish to close Installation Enabling Gigabit Interface 18 Enable Gigabit Ethernet Interface optional
30. n all places Recalibrate the scanner as described under Maintenance Calibration Maintenance 41 Replacing the Dust Filters Fresh dust filters can reduce the amount of time spent on cleaning and calibration The dust filters protect your scanner s air cooling vents Your scanner monitors usage of the filters and will warn you when it is time for a replacement through WIDEsystem Replacing the Dust Filters p Turn scanner power off and disconnect 1 Press the main power switch scanner back to OFF 2 Disconnect the power plug Replacing the Dust Filters 2 Locate the air vent and dust filter bin Locate the square shaped dust filter bin on the underside of the scanner Maintenance Replacing the Dust Filters 2 Detach the bin Insert a screw driver or other flat tool under one of the bin s corners to snap it down and detach it from its frame Replacing the Dust Filters Replace the filter The filter soft material is inside the bin Remove the old filter and replace with a fresh one Maintenance Replacing the Dust Filters 5 Reattach the bin Reattach click on the bin to its frame on the underside of the scanner Maintenance Downloading New Firmware What is Firmware Like a computer your scanner needs an operating system in order to work This operating system is called Firmware Firmware runs inside the scanner
31. nd follow the instructions on your screen to install the scanner on your PC 2 Most of the scanner installation process is automatic 3 Wait until the completion message appears 4 Press Next when done A IMPORTANT During all installation steps be sure to select YES if Windows asks you to allow the software to access the network 2 Scanner Installation Wizard Connect your scanner to your PC with a USB cable Make sure the scanner is tumed on and your PC has connection to the scanner Windows may show you one or more dialogues when a scanner is being connected for the first time Please complete it before you click on Next to continue f your firewall blocks network traffic then you need to unblock the program and click the Refresh button in the next wizard page Scanner Installation Set energy star idle time preference On delivery the scanner is set for automatic entry into sleep mode after a preset idle time i e the length of time the scanner is not active The default idle time setting for energy star compliancy is 15 minutes You may wish to prolong it to avoid frequent automatic shutdowns Set a new idle time or select do not sleep to deactivate automatic entry into sleep mode Scanner Installation Wizard The scanner XX200c Not Activated USB has an Energy Star function and enters sleep mode after being idle for 15 minutes You may change this setting here 15
32. ns 1 Open WIDEsystem double click the WIDEsysem icon na system tray 2 Select the Timer Tab 3 Select or deselect the Enter Sleep mode automatically option 4 If you do not select the Enter Sleep mode automatically option you will need to use the manual method for entering sleep mode by holding the power button down for 3 seconds 5 If you do select Enter Sleep mode automatically option proceed to the next step to set the dle time value 6 Set the value dle time before entering sleep This is the number of minutes the scanner can stand idle before entering the sleep mode on its Own inthe 22 7 Press Apply to download your settings into the scanner s memory lv Enter Sleep mode automatically Idle time before entering Sleep minutes 15 Sleep Mode options in the WIDEsystem program Timer tab Bf nore With the scanner main power ON the scanner can be also be brought into Wake up and Sleep modes manually even while the Enter sleep mode automatically option is selected e Wake by pressing any button on the panel e Sleep by pressing and holding down the power button for 3 seconds You can choose to disable automatic entry into Sleep mode entirely if you want only manual activation of the sleep mode or you can leave it enabled and retain both manual and automatic functions Scanner in Wake mode LEDs are green Scanner in Sleep mode Power LED is orange Loading Loading Origina
33. or smudged internal glass plate or white background platen Clean the scanning area reboot the scanner and then complete the maintenance steps as described in the section Maintenance in this guide If the problem persists after cleaning the scanner area and all above possibilities have been attempted summon your technical service provider Check the One Touch setup entries in WIDEsystem Click on the scanner icon to open WIDEsystem and select the One Pp pucalion Copbornaye LONE TONEN eoimer Touch tab View WIDEsystem Help for instructions work Check that the applications defined in the WIDEsystem One Touch setup entries are installed on your PC Make sure that the applications defined in the WIDEsystem One Touch setup entries are actually designed to work with compatible with your scanner s application control keys See the application s documentation or contact the application software dealer Can t operate or contact scanner after A power failure could interrupt an ongoing firmware upgrade process The scanner will not run correctly after an interrupted Firmware upgrade failure firmware update process Only part of the intended firmware may be loaded rendering the scanner inaccessible You need reboot the scanner to Safe Mode to reapply the firmware Restart the scanner If the scanner detects corrupted firmware it will start up in Safe Mode Confirm Safe Mode Open WIDEsystem double click the WIDEsystem scanner icon on your
34. ot in use A Caution Make sure the scanner power is OFF when using the dust cover Maintenance Calibration Scanner calibration is very easy to perform Calibration is carried out using the W DEsystem program you installed with your drivers After manually cleaning the scan area you just start the Calibration wizard and let it take over The wizard will ask you to insert a calibration sheet Other than that scanner calibration is completely automatic f note Cleaning and calibration are tied together Cleaning the scanner creates the need for renewed calibration and correct calibration will always require a clean scan area Calibration barn the scanner power ON Make sure that the scanner has been turned ON and in Wake mode for at least 5 minutes prior to calibration The short warm up time will ensure that camera and light conditions have stabilized Maintenance Calibration sie Launch the scanner calibration wizard 1 On your PC Double click on the WIDEsystem icon E in the system tray to open the WIDEsystem program 2 Press the Calibrate button Scanner Messages No messages Maintenance Messages No maintenance required Calibration sie Select the Calibration type Select either Camera Alignment or Full Calibration e Camera Alignment will align the camera horizontally to the first scan line e Full Calibration will perform Camera Alignment
35. our manufacturer s website or contact your dealer to obtain the right WIDEsystem version WIDEsystem drivers were not installed before connecting the scanner Shut down the scanner and PC unplug the connections and restart the installation from step 1 as described above Loose interface connection on both end unplug and then firmly plug in the interface cable System needs rebooting shut down the scanner and PC unplug the connections Then plug in the interface connections turn on the PC and when Windows is loaded turn on the scanner Trouble Shooting Problems Related to Operation of the Scanner Possible Causes and Remedies Error Indicator LED blinking An error was detected The error may be reported immediately through a message on your screen If not open WIDEsystem scanner icon on your system tray and select the Status tab to view additional information about the error Perform one of the following The information on your screen may include instructions and actions to remedy the error Follow the instructions on your screen Look for a description of the error in this users guide Follow the instructions provided In some cases you may need technical assistance You should contact your service provider if one or more of the following cases is true a the error cannot be remedied through the action suggested on your PC screen b the error and its remedy is not described in this users guide c t
36. ower outlet A CAUTION The scanner is equipped with a three wire pin grounding type plug If you cannot insert the plug into your outlet contact your electrician to replace the plug or outlet to ensure a grounded power connection Do not try to defeat or ignore the purpose of the grounding type plug O S It Installation Power ON the scanner 8 Turn ON scanner power Turn on the main power switch at the back of the scanner Connect Cables 9 Connect the USB interface cable to the scanner Initial installation and activation of the scanner is easiest using the USB connection This applies also for Gigabit enabled models 1 The interface connection panel is found at the back of the scanner on its left side when facing the back 2 Connect the B connector end square shaped end to a USB port on the scanner B nore For Gigabit enabled scanner models The installation wizard will instruct you on installation and activation of the gigabit interface later in the installation process For now only connect the USB Regulatory Notice Your scanner product has been tested to comply with the EMC Standards EN55022 and FCC Part 15 To maintain compliance only use the interface cables supplied with the scanner IMPORTANT Do not yet connect the other end of the USB to the PC Installation Connect USB cable to PC 10 Connect the USB interface cable to the PC 1 On th
37. r machine Then right click on the scanner icon select Advanced Options gt Update Scanner Firmware to install it on your scanner Initiate a scan of the system s hardware bus for re establishing the interface Right click on the scanner icon select Advanced Options gt Rescan Hardware Bus Assign reassign applications to the scanner s one touch scan buttons or disable the one touch scan buttons altogether Open the One Touch tab to make settings Set up your scanner so it can be shared by other PC s on the network Open the Scan to Net tab to make settings See also Installation Share the scanner on the LAN 28 Set up your scan software so it can access shared scanners on the network Open the Scan to Net tab to make settings Launch the WIDEsystem on line help To find instructions on trouble shooting and using WIDEsystem with your scanner Open WIDEsystem and press the F1 key Activate and upgrade your scanner Open the License tab You will need to have a valid license for the activation upgrade Launch the scanner calibration wizard Right click on the scanner icon select Calibrate Launch the WIDEsystem on line help To find instructions on trouble shooting and using WIDEsystem with your scanner Open WIDEsystem and press the F1 key Maintenance Maintenance Overview key maintenance points About scanner maintenance The illustrations below indicate the parts and areas you need to ean lhe elton
38. rawings printed or pasted on thick media such as cardboard foamboards gatorboards etc e Your flatbed scanner can accommodate originals up to 1 5 38 mm thick while still allowing you to close the cover e You can also scan very thick originals by placing the original on the scanner bed and leaving the cover completely open 27 Monitoring your scanner with WIDEsystem You installed WIDEsystem with the scanner drivers WIDEsystem contains an application that monitors the scanner and reports on its functionality Double left click the system tray s WIDEsystem icon to open the WIDEsystem control interface Scanner mode Ready Original Ready Original has been loaded scanner Messages No messages Maintenance Messages No maintenance required WIDEsystem program control interface Scanning With WIDEsystem you can View the scanner s status Move the mouse over the scanner icon on the system tray Status messages include whether or not the scanner is detected connection and runtime errors and readiness for scanning Scanner status message on Windows system tray View Error messages and logs Runtime errors are reported immediately on your screen You can also open the Status tab and Log tab for viewing error messages View information about the scanner device in relation to firmware and hardware revisions Open the nfo tab Install new firmware You download new firmware to a folder on you
39. roducts plugged into the extension cord does not exceed the extension card ampere rating Make sure that the total rating of all products plugged into the wall outlet does not exceed 15 amperes H Slots or openings in the cabinet at the back or bottom are provided for ventilation This ensures reliable operation of the product and protects it from overheating These openings must never be blocked or covered The openings should never be blocked by placing the unit on a bed sofa rug or other similar soft surface This product should never be placed near or over a radiator or heat register This product should not be placed in a built in installation unless proper ventilation is provided I Never push objects of any kind into the scanner through cabinet slots since they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock Avoid any possibility of spilling liquid of any kind on the scanner J Do not attempt to service the scanner yourself Opening or removing those covers requiring tools may expose you to dangerous voltage points or other risks Refer all servicing in those compartments to authorized service personnel K Unplug the scanner from the wall outlet and refer servicing to authorized service personnel under the following conditions e When the power cord or plug is damaged or frayed e If liquid has been spilled into the scanner e If the scanner has been exposed to rain or water
40. ructions Scan Application button Copy Application button Email Application button The one touch buttons on the panel Nextimage Scan Copy button The green button duplicates the scan copy button in the Nextimage software Once you set Nextimage to scan or copy with the right settings pressing the green Scan Copy button on the scanner activates the process from the scanner rather than from the PC This is useful for example to facilitate fast and convenient feeding and scanning of multiple pages see Batch scanning below NEXTimage button Batch scanning Batch scanning involves jobs where you want to feed and scan a whole set of originals that require equal scan settings The basic steps are 1 In Nextimage set your scan or copy settings size type image adjustments for the batch Your settings will apply to ALL the documents in the batch 2 Feed the batch s documents one by one pressing the green Nextimage Scan Copy button at the scanner for each document 3 If using a scan or copy software other than Nextimage you can configure and use the one touch buttons to batch scan Read you scan software s on line help pages for specific information on batch scanning with the application B nore The availability of Batch scanning options will depend on your scan copy software and its level of compatibility with the scanner model Scanning Scanning Thick Media You may need to scan documents and d
41. s apply only for scanners using USB interfacing to PCs Gigabit interfaced scanners will be shared automatically 1 Make sure your PC with the scanner connected via USB is connected to the LAN 2 Double click on the WIDEsystem program icon and select the Network tab 3 Select the option Share the scanner on the network 4 Press the OK button to accept the settings On most LAN systems this is all you have to do However some systems will require Advanced settings such as specific communication port numbers Contact your LAN administrator for information regarding Advanced settings Bf nore Open WIDEsystem and press the lt F1 gt key for viewing complete on line help regarding the Network setup procedures and options including Advanced settings NOTE PCs on the LAN that will use the scanner must be installed with WIDEsystem and compatible scan copy software T WIDEsystem ae Status Info _ Timer_ One Touch Selected Scanner E Share the scanner on the network Advanced Network Scanner Add a network scanner to your scanner list Turning the Scanner ON OFF Turning Power ON OFF Main power switch The main power switch is at the back of the scanner on the right Press the upper half of the switch marked I to turn the main power to ON Press the lower half of the switch marked O to turn the main power to OFF Main power switch is at the back of the scanner Pre
42. s asks you to allow the software to access the network A CAUTION DO NOT YET CONNECT THE SCANNER TO POWER OR TO THE PC This is to ensure your own personal safety and to help protect your device from potential damage during cleaning in the next steps 6 After installing software leave the PC ON as you perform the next steps to prepare and setup the scanner Installation Cleaning the scanner Open the scanner lid The internal scan area glass plate should be wiped clean for any dust accumulated during packaging and shipping The scan area is under the scanner lid so you have to open it Pull back the scanner lid to expose the scan area glass plate Cleaning the scanner 5 Clean the internal scan area Lightly wipe the internal scan area s glass plate free of dust Use a dry lint free cloth If you detect difficult smudges on the glass that cannot be wiped clean with a dry cloth refer to this guide s section Cleaning the scan area for instructions on thoroughly cleaning the scan area Close the lid after cleaning the internal scan area Installation Connect power cable Connect the power cable to the scanner Connect the scanner power cable to the scanner s main power connection socket The main power connection socket is at the scanner s back Connect power cable 7 Connect the scanner to a power outlet Connect the power plug end of the scanner power cable to a p
43. ss I for ON and 0 for OFF The scanner s Self Test Procedure When you turn the main power ON the scanner runs a short self test procedure This takes less than one minute The LEDs on the panel will be on during the self test procedure Both LEDs are ON during self test Scanner ready to scan The scanner is ready for scanning when the power and Nextimage LEDs turn green The scanner starts up in Wake mode see next section You can leave the main power switch permanently ON and control scanner power through its Sleep and Wake modes Panel when Scanner is Ready in Wake mode Eror defected Eror indicator bisiks Turning the Scanner ON OFF Wake and Sleep modes With the main power switch ON scanner power can be set in Sleep mode and Wake mode Sleep mode is the energy saving mode The scanner cannot scan when in the Sleep mode Wake mode is the full power ON mode for scanner operation The scanner will go from Wake mode into Sleep mode e Automatically after a set idle time see section Automatic shut down after idle time e Manually when you hold the power button down for 3 seconds Hold down the power button fo Scanner in Sleep mode Power LED is enter Sleep mode orange Nextimage LED is off The scanner will go into wake mode e When you press any button on the panel Scanner in Wake mode LEDs green Advantages with using Wake up and Sleep modes Ready faster
44. system tray The Scanner field should show Scanner is in Safe Mode Follow the steps for firmware installation L NOTE Safe Mode is only for repairing a corrupted or interrupted firmware installation Do not attempt to use the scanner when it is in Safe Mode Trouble Shooting Problems Related to the Scanning Results Possible Causes and Remedies Check in your scanning application that your size settings are either for Auto detection or correspond to the size of the whole Not whole image scanned original 2 Check that you are loading the original correctly from the scanner s right side This is often caused by an unclean glass plate Even a single spec of dirt in the wrong spot on the glass plate can apply a streak One or more thin vertical lines show up in along your entire scan To remedy the scanned image but not in the original Clean your glass plate as described in this users guide drawing Most dirt on the glass plate is introduced by the documents Wipe clean the document with a dry lint free cloth before feeding the document into the scanner If the problem persists after cleaning start WIDEsystem and calibrate the scanner The scanner may have memorized dirt specs and you need to recalibrate after dirt removal If the problem persists after cleaning and calibration Check the glass plate for scratches A damaged glass plate should be replaced Contact your service provider for information