Home

“FN” / “FSN” Series “PN” Series - Sta-Rite

image

Contents

1. 4 Attach the incoming power leads to the two outer screws on the pressure switch as shown in Figure 8 screws on the pressure switch as shown in Figure 6 4 Attach the ground wire to the grounding connections 5 Attach the ground wire to one of the grounding as shown in Figure 8 connections shown in Figure 6 5 If there are other wires they should be capped 6 If there are other wires they should be capped 6 Reinstall the motor end and pressure switch covers 7 Reinstall the motor end and pressure switch covers Electrical 8 44 WARNING Hazardous voltage Can shock burn or kill Connect ground wire before connecting power supply wires Use the wire size including the ground wire specified in the wiring chart If possible connect the pump to a separate branch circuit with no other appliances on it A WARNING Explosion hazard Do not ground to a gas supply line Wiring Connections WARNING Fire hazard Incorrect voltage can cause a fire or seriously damage the motor and voids the warranty The supply voltage must be within 10 of the motor nameplate voltage NOTICE Dual voltage motors may be set for 115 V or 230 V If necessary reset the motor to the desired voltage as shown Do not alter the wiring in single voltage motors Install ground wire and maintain your pump in compliance with the National Electrical Code NEC or the Canadian Electrical Code CEC as applicable and wit
2. Abra el grifo y drene hasta que el agua deje de correr Drene la bomba Es posible que su bomba tenga un tap n de drenaje separado Saque este tap n y drene Es posible que su bomba tenga s lo un tap n o una conexi n del lado de la bomba Saque y drene la bomba Un poco de agua permanecer en la bomba Una peque a cantidad de agua en la bomba no la perjudicar si se congela Soluci n de problemas S ntoma El motor no funciona El motor se calienta y dispara la sobrecarga El motor funciona pero no sale agua AVIS Detenga la bomba despu s verifique el cebado antes de buscar otras causas Destornille el tap n de cebar y vea si hay agua en el orificio de cebado La bomba no produce agua a toda su capacidad Tambi n verifique el punto 3 de arriba La bomba entrega agua pero no se apaga o los ciclos de bombeo son demasiado frecuentes Sale aire de los grifos 21 El interruptor de desconexi n est apagado Verifique que el interruptor est encendido El fusible est quemado o el disyuntor se abri Reemplace el fusible o reposicione el disyuntor El interruptor de encendido est defectuoso DESCONECTE LA CORRIENTE EL CTRICA reemplace el interruptor de encendido Los cables en el motor est n sueltos desconectados o conectados incorrectamente Consulte las instrucciones sobre el cableado p gina 39 DESCONECTE LA CORRIENTE EL CTRICA inspeccione y ajuste todo el cableado A ADVERTENCIA La
3. a cinco pies sobre el fondo Tambi n debe estar a por lo menos 10 pies debajo del nivel del agua a fin de evitar que la bomba succione aire Instale una T para cebar tap n para cebar y la tuber a de succi n a la bomba vea la Figura 3 Soporte la tuber a para que no haya inclinaciones verticales o hundimientos en ella a fin de que no ejerza tensi n sobre el cuerpo de la bomba y con el prop sito de que no se incline ligeramente hacia arriba desde el pozo hacia la bomba los puntos altos pueden ocasionar que se formen bolsas de aire que pueden bloquear la bomba Sellar las juntas de la tuber a de aspiraci n con cinta selladora de PTFE para roscas de tuber a Las juntas deben ser a prueba de agua o estar herm ticamente cerradas Si la tuber a de succi n pudiera succionar aire la bomba no podr sacar agua del pozo Usted acaba de realizar la conexi n de tuber a de succi n para su nueva bomba tipo jet para pozo poco profundo por favor pase a la P gina 17 para realizar las conexiones del tanque y de la tuber a de descarga Tuber a de descarga y Conexiones del tanque de presi n Al sistema dom stico de agua Te de lt cebadura de la bomba con tap n o IQ man metro Interruptor Desde de presi n N el pozo Figura 4 Conexiones del Tanque Pre cargado Al sistema dom stico de agua Te de BN bomba gon tap nco Tubo de control de r p volumen de aire man metro Control de vol
4. ctica no relacionada con una lesi n f sica Lea y siga cuidadosamente todas las instrucciones de seguridad en este manual y en la bomba Mantenga las etiquetas de seguridad en buenas condiciones Reemplace las etiquetas de seguridad faltantes o da adas Advertencia de la Proposici n 65 de California A ADVERTENCIA Este producto y accesorios relacionados contienen sustancias qu micas reconocidas en el Estado de California como causantes de c ncer malformaciones cong nitas y otros da os al sistema reproductivo Conecte el motor al voltaje correcto Vea la secci n Electricidad en este manual y la placa del motor Ah ADVERTENCIA lt Conecte el motor a tierra antes de conectarlo a la alimentaci n de energia A Cumpla con las indicaciones del C digo Nacional El ctrico el de Canada y los c digos locales para toda la conexi n el ctrica A Siga las instrucciones de conexion el ctrica en este manual al conectar el motor a las lineas de energia el ctrica Voltaje peligroso Puede ocasionar conmoci n quemaduras e incluso la muerte Conecte la bomba a tierra antes de conectarla a la alimentaci n el ctrica Desconecte la alimentaci n de energ a antes de trabajar en la bomba el motor o el tanque 13 Seguridad electrica A ADVERTENCIA El voltaje del capacitor puede ser peligroso Para descargar el capacitor del motor tome un desatornillador con
5. gt PENTAIR STA RITE PN Series Installation Operation Parts For further operating installation or maintenance assistance Call 1 888 782 7483 English 22 5ieza Pages 2 11 293 WRIGHT STREET DELAVAN WI 53115 WWW STA RITE COM PH 888 782 7483 O 2013 Pentair Ltd All Rights Reserved OWNER S MANUAL Shallow Well Jet Pumps Tank Systems MANUAL DEL USUARIO Sistemas de bombas tip jet tanques para pozos poco profundos FN FSN Series Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 888 782 7483 Espanol Paginas 12 20 S919 Rev 02 22 13 Safety Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation operation and maintenance of the product Save this manual for future reference A This is the safety alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury indicates a hazard which if not avoided will result in death or serious injury A WARNING indicates a hazard which if not avoided could result in death or serious injury A CAUTION indicates a hazard which if not avoided could result in minor or moderate injury NOTICE addresses practices not related to personal injury C
6. lvula de retenci n funcione libremente 3 Bajela tuber a hacia el pozo hasta que el filtro se encuentre a cinco pies sobre el fondo del pozo Tambi n debe estar a por lo menos 10 pies debajo del nivel del agua del pozo cuando la bomba est funcionando a fin de evitar que la bomba succione aire Instale un sello sanitario para pozo Instalaci n Te de cebadura de la bomba con tap n o e man metro Al Sistema Dom stico de Agua Tubo de succi n que proviene de la fuente de agua T y Tap n para Cebar A Por lo V lvula de menos 10 Retenci n 5y10 D Screen Malla SAH Figura 3 Instalaci n para agua superficial 16 Instale una T para cebar tap n para cebar y la tuber a de succi n a la bomba vea la Figura 2 Conecte la tuber a del pozo al orificio de succi n de la bomba utilice el menor n mero de conexiones posible especialmente codos ya que las conexiones incrementan la fricci n de la tuber a pero incluya una v lvula de aspiraci n vea la Figura 2 La tuber a de succi n debe ser por lo menos del mismo tama o que el orificio de succi n de la bomba Soporte la tuber a para que no haya inclinaciones verticales o hundimientos en ella a fin de que no ejerza tensi n sobre el cuerpo de la bomba y con el prop sito de que no se incline ligeramente hacia arriba desde el pozo hacia la bomba los puntos altos pueden ocasionar
7. mango aislado POR EL MANGO y ponga en corto las terminales del capacitor No toque la superficie de metal del desatornillador ni las terminales del capacitor Si tiene alguna duda consulte a un electricista calificado Seguridad general A PRECAUCI N No toque un motor en operaci n Los motores modernos est n dise ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del sistema se congele Hacerlo invalidar la garant a Utilice esta bomba s lo para agua Inspeccione la bomba y los componentes del sistema peri dicamente Utilice gafas de seguridad durante todo el tiempo mientras trabaje en la bomba El rea de trabajo se debe mantener limpia ordenada y con iluminaci n adecuada guarde las herramientas y el equipo que no utilice en el lugar apropiado Mantenga a los visitantes a una distancia segura de las reas de trabajo A ADVERTENCIA El cuerpo de la bomba puede explotar si se utiliza como una bomba propulsora a menos que se instale una v lvula de alivio que sea capaz de pasar todo el flujo de la bomba a 75 psi AX ADVERTENCIA Presi n peligrosa Instale una v lvula de alivio de presi n en la tuber a de descarga Libere toda la presi n en el sistema antes de trabajar en alguno de los componentes Gara
8. n excesiva El tanque de presi n est ndar est inundado y no tiene amortiguador Drene el tanque a la abertura de regulador de volumen de aire Verifique de aire que el AVC no presente defectos Verifique que no haya fugas de aire en ninguna conexi n Las tuber as presentan fugas nspeccione las conexiones Las v lvulas de pie presentan fugas Reemplace la v lvula de pie El man stato est desajustado Ajuste o reemplace el man stato La carga de aire es demasiado baja en el tanque precargado La bomba est cebando Fuga del lado de la aspiraci n de la bomba El pozo es gaseoso Sobre bombeo intermitente del pozo aspiraci n adicional de agua por debajo de la v lvula de pie DESCONECTE LA CORRIENTE EL CTRICA y abra las llaves hasta que se haya iberado la presi n Mida la presi n del aire en el tanque con un man metro para neum ticos en el vee de la valvula que se encuentra en el tanque Si a presi n es menor que la del disparo del man stato 30 50 PSI bombee aire hacia el tanque desde una fuente externa hasta que la presi n del aire sea 2 PSI menos que la presi n de disparo del interruptor Verifique que no haya fugas en la v lvula de aire utilice una soluci n jabonosa y reemplace el n cleo si uese necesario Cuando la v lvula est cebando deber a bombar s lo agua sin aire La tuber a de aspiraci n est aspirando aire Verifique que no haya fugas en las juntas usando agua jabonosa Consulte
9. or any system component to freeze To do so will void warranty Pump water only with this pump Periodically inspect pump and system components Wear safety glasses at all times when working on pumps Keep work area clean uncluttered and properly lighted store properly all unused tools and equipment Keep visitors at a safe distance from the work areas A WARNING Pump body may explode if used as a booster pump unless relief valve capable of passing full pump flow at 75 psi is installed 44 WARNING Hazardous pressure Install pressure relief valve in discharge pipe Release all pressure on system before working on any component Warranty 3 Retain Original Receipt For Your Records Limited Warranty STA RITE warrants to the original consumer purchaser Purchaser or You of the products listed below that they will be free from defects in material and workmanship for the Warranty Period shown below Product Warranty Period whichever occurs first 12 months from date of original installation or 18 months from date of manufacture Water Systems Products jet pumps small centrifugal pumps submersible pumps and related accessories Pro Source Composite Tanks 5 years from date of original installation Pro Source Steel Pressure Tanks 5 years from date of original installation Pro Source Epoxy Lined Tanks 3 years from date of original installation 12 mont
10. the pump mounting height so that the plumbing connections do not put a strain on the pump body Support the pipe so that the pump body does not take the weight of piping or fittings You have just completed the well plumbing for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections Well Point Driven Point Installation Figure 1 is Drive the well using drive couplings and a drive cap Drive fittings are threaded all the way through and allow the pipe ends to butt against each other so that the driving force of the maul is carried by the pipe and not by the threads The ordinary fittings found in hardware stores are not threaded all the way through the fitting and can collapse under impact Drive fittings are also smoother than standard plumbing fittings making ground penetration easier Mount the pump as close to the well as possible Use the fewest possible fittings especially elbows when connecting the pipe from the well point to the pump suction port The suction pipe should be at least as large as the suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pi
11. water from the well Electrical 7 Ah Disconnect power before working on pump motor pressure switch or wiring Motor Switch Settings NOTICE 1 2 HP and 1 3 HP motors are dual voltage and are factory set to 115 V 3 4 HP motors are also dual voltage but are factory set to 230 V Motor terminal board located under the motor end cover should look like that shown below Use the instructions to set your motor to match your power source A WARNING Never connect a motor set to 115 V to a 230 V power source Plug Type Voltage Selector Dial Type Voltage Selector Voltage is set to 230 V To change to 115 V Power Connections Voltage is set to 230 V To change to 115 V ZEE Power Supply Connections d lt TR j p Pressure Switch bola aa Pressure Switch Ground Wire Connection L Figure 6 Voltage set to 230 V Plug Type Figure 8 Voltage set to 230 V Dial Type 1 Make sure power is off 2 Pull the voltage change plug off of the tabs 1 Make sure power is off 3 Move the voltage change plug to the 115 V position 2 Turn the dial counter clockwise until 115 shows in The plug will now cover 2 metal tabs and the arrow the dial window as shown in Figure 9 on the plug will line up with the 115 V arrow on the label see Figure 7 i Figure 9 Voltage set to 115 V Dial Type boa o f Figure 7 Voltage set to 115 V Plug Type 3 Attach the incoming power leads to the two outer
12. 218 582A 115 PKG 17351 0009 17351 0009 17351 0009 17351 0009 A Seal Plate Assembly Incl 45 N103 12PSS N103 12PSS N103 12PSS Stainless Steel Insert 33 255 33 255 33 255 O Ring U9 390 U9 390 U9 390 U109 6A U109 6A U109 6A J105 40PF J105 42PTB J105 40PF N C35 41 C35 41 C35 41 N1 28P N1 28P N1 28PA U30 738SS U30 738SS U30 738SS N176 35P N176 35PA N176 35P 10 Capscrew 10 16 Hex Head 11 Tank Body Ass y incl 12 thru 18 12 13 Pipe Plug 1 8 NPT Taped 14 Comp Elbow 1 4 NPT w TFE 15 7 17 Jet Body Insert N76 29P 18 Capscrew 10 16 U30 74255 9 tr SEERE 5 5 3 cla gt g g 2l5 8 S9 amp l9 6 n g e a d N76 35P N76 35P N76 35P N76 35P WC78 41T WC78 41T WC78 41T U111 86T U37 670P J20 18 N76 29P U30 742SS N34P 19 N32P 66 U9 201 J104 9F U43 12ZP U36 38ZP C35 5 U217 1216 U36 112ZP L43 5C PP1521 PP1530 WC78 40T U111 86T U111 86T U37 670P U37 670P Ole Bis 2 oix ls zm g gt ES a Ss lt J20 18 N76 29P U30 742SS N34P 17 N32P 78 U9 201 J104 9F U43 12ZP U36 38ZP C35 5 Plastic un fto 22 AH 19 N34P 17 N34P 17 20 N32P 78 N32P 78 21 O Ring U9 201 U9 201 J104 9F J104 9F 22 Base Assembly Painted 23 24 25 26 27 28 4 U43 12ZP U43 12ZP 4 U36 38ZP U36 38ZP 4 4 0355 Pressure Switch U217 1216 U217 1216 87 U36 112ZP U36 112ZP L43 5C L43 5C PP1520 PP1520 PP1530 PP1530 Zz gt PP1530 olc Alzazic
13. a 115V o 230 V De ser necesario vuelva a configurar el motor a la tensi n deseada seg n se ilustra No modifique el cableado en los motores de tensi n singular Instale ponga a tierra conecte los alambres y mantenga su bomba conforme al C digo Nacional de Electricidad NEC o al C digo Canadiense de Electricidad CEC seg n corresponda y conforme a todos los c digos y normas locales que correspondan Consulte con su inspector local de construcciones para obtener informaci n sobre los c digos Procedimiento para las conexiones 1 Conecte el alambre de puesta a tierra primero seg n se ilustra en la Figura 6 El alambre de puesta a tierra debe ser un alambre de cobre s lido por lo menos tan grande como los alambres de suministro de corriente 2 Debe haber una conexi n met lica s lida entre el conmutador a presi n y el motor para brindar protecci n a tierra para el motor Si el conmutador a presi n no est conectado al motor conecte el tornillo de puesta a tierra verde en el conmutador al tornillo de puesta a tierra verde debajo de la tapa de extremo del motor Use un alambre de cobre s lido que sea por lo menos tan grande como los alambres de suministro de corriente 3 Conecte el alambre de puesta a tierra a un alambre conectado a tierra del tablero de servicio a un tubo met lico para agua subterr nea a un entubamiento met lico para pozos de por lo menos 3 metros 10 pies de largo o a un electrodo a ti
14. a desde el punto del pozo al orificio de succi n de la bomba La tuber a de succi n debe ser por lo menos del mismo tamafio que el orificio de succi n en la bomba incluya una v lvula check si su equipo no est equipado con una Vea la Figura 1 Soporte la tuber a para que no haya inclinaciones verticales o hundimientos en ella a fin de que no se ejerza tensi n sobre el cuerpo de la bomba y con el prop sito de que no se incline ligeramente hacia arriba desde el pozo hacia la bomba los puntos altos pueden ocasionar que se formen bolsas de aire que pueden bloquear la bomba Sellar las juntas de la tuber a de aspiraci n con cinta selladora de PTFE para roscas de tuber a Las juntas deben de ser a prueba de agua y estar herm ticamente cerradas Si la tuber a de succi n pudiera succionar aire la bomba no podr a sacar agua del pozo Si un punto de pozo no proporciona suficiente agua considere la posibilidad de conectar dos o tres puntos de pozo a una tuber a de succi n Usted acaba de realizar la conexi n de tuber a de succi n para su nueva bomba tipo jet para pozo poco profundo Por favor pase a la P gina 24 para realizar las conexiones del tanque y de la tuber a de descarga Instalacion de pozo recubierto con un recubrimiento de 2 o mas Figura 2 1 Monte la bomba tan cerca del pozo como sea posible 2 Instale la v lvula de retenci n el filtro y la tuber a del pozo vea la Figura 2 Aseg rese de que la v
15. a la f brica sobre la instalaci n de una camisa en el pozo Baje la v lvula de pie si es posible de lo contrario restrinja la descarga de omba Piezas de repuesto 22 Vista esquem tica Serie PN 1 3 a 3 4 HP PNCSS 1 12 HP Puerto Serie PN 1 3 a 3 4 HP Modelo PNCSS 1 2 HP Clave No Descripci n de la parte Modelo y HP Cantidad Modelo HP PNB 1L PNC 1L PND 1L PNCSS ra A a a va gt gt pa oa sam am Ls pem EU AECA AECI p Nus Nem Ensamble del cuerpo del tanque incl 12 a 18 DN DC NICE DN EN E Tap duo TNT cng T boo de Comp VI RFT CTE Pas ums meer T Pium E mE C wee p wm I 2 sare dete rr re re 5 enieidesqeitisr ee urea em em rai A ar ua Hr A pS ps nero dep re ars ne a7 etes der A a enze gt 3s emecerdegr esc T 31 eran geral rss res men NA stoy empaque e o so mse mo PNCSS utilice un Tapon de 1 4 NPT no WC78 40T of E ET MC AT Piezas de repuesto 23 Vista esquem tica Serie FSN 1 2 y 3 4 HP FNC L 12 HP FND L 3 4 HP Serie FSN 1 2 y 3 4 HP Descripti n de la parte Cantidad Modelo y HP oe 1 2 HP 3 4 HP 1 2 HP Anillo del difusor Ensamble del cuerpo de la bomba N176 38 N176 38F N176 38 3 pese EE ES NENNT A Em 3 ow 5 Lowe HEN E
16. ancarla 1 Quitar el tap n de cebado de la bomba y llenar la bomba llenar toda la tuber a que va de la bomba el pozo y asegurese que toda la tuber a del pozo est llena En caso de haber instalado una T de cebado en la tuber a de succi n quitar el tap n de la T y llenar la tuber a de succi n Vuelva a colocar todos los tapones de llenado Enci ndala Arranque la bomba Si no tiene agua despu s de 2 a 3 minutos detenga la bomba y retire los tapones Vuelva a llenar la bomba y la tuber a Es probable que tenga que repetir este paso varias veces con el fin de sacar todo el aire atrapado dentro de la tuber a Es probable que necesite hasta 15 minutos para cebar la bomba con una elevaci n de agua de 25 Despu s de que la bomba ha producido presi n en el sistema y est apagada verifique la operaci n del interruptor de presi n abriendo una llave o dos y dejando correr suficiente agua para descargar la presi n hasta que la bomba arranque La bomba debe arrancar cuando la presi n caiga a 30 PSI y se debe detener cuando la presi n alcance los 50 PSI Haga funcionar la bomba durando uno o dos ciclos completos para verificar su correcta operaci n Esto tambi n le ayudar a limpiar el sistema de polvo y basura producida durante la instalaci n Preparaci n de la bomba para el invierno Para preparar la bomba en caso de temperaturas heladas T 2 Corte la alimentaci n a la bomba Descargue la presi n del sistema
17. arefully read and follow all safety instructions in this manual and on pump Keep safety labels in good condition Replace missing or damaged safety labels California Proposition 65 Warning 44 WARNING This product and related accessories contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING 0 S Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank Wire motor for correct voltage See Electrical section of this manual and motor nameplate Ground motor before connecting to power supply Meet National Electrical Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connecting motor to power lines Electrical Safety A WARNING Capacitor voltage may be hazardous To discharge motor capacitor hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a qualified electrician General Safety A CAUTION Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump
18. as uniones de los tubos en la tuber a de succi n est n unidas herm ticamente y son impermeables al agua Si la tuber a de succi n puede succionar aire la bomba no podr jalar agua del pozo 3 Ajuste la altura de montaje de la bomba de modo que las conexiones de plomer a no ocasionen un esfuerzo de deformaci n sobre el cuerpo de la bomba Dele el soporte adecuado a los tubos de modo que el cuerpo de la bomba no reciba todo el peso de la tuber a o los herrajes Usted acaba de terminar las conexiones de plomer a del pozo de su nueva bomba tipo jet para pozo poco profundo Consulte la P gina 24 para realizar las conexiones del tanque y de la tuber a de descarga Instalacion del punto del pozo punto de hincar Figura 1 1 Hinque el pozo utilizando manguitos de tuber a de hincar y una caperuza para la hinca Las conexiones de perforar est n roscadas a todo lo largo y permiten que los extremos de la tuber a empalmen para que la fuerza de perforaci n del mazo sea soportada por la tuber a y no por el enroscado Las conexiones ordinarias que se encuentran en las tlapaler as no est n roscadas a todo lo largo y se pueden colapsar por el impacto Las conexiones de hincado tambi n son m s suaves que las conexiones de plomer a comunes y esto facilita la penetraci n en el suelo Monte la bomba tan cerca del pozo como sea posible 3 Utilice el menor n mero de conexiones posible especialmente codos al conectar la tuber
19. auge The pre charge should be 2 PSI less than the cut in setting of the pump s pressure switch The pre charge is measured when there is no water pressure in the tank Your new pump has a 30 50 PSI switch so adjust the tank pre charge pressure to 28 PSI Congratulations You have just completed the tank connection for your jet pump Please go to Page 7 for electrical hookup Model PNCSS does not include a pressure switch Standard Tank Connection Figure 5 1 2 Install one tee in the pump discharge port see Figure 5 Run a pipe from the pump discharge port to the inlet port of your tank The pipe size must be at least as large as the discharge port Install a tee in the suction pipe near the pump Install a reducer bushing down to 1 8 NPT in the tee Run tubing from the tee to the port on the AVC mounted on the tank Seal all joints with PTFE pipe thread sealant tape See instructions provided with the tank and the AVC for details Congratulations You have just completed the tank connection for your jet pump Please go to Page 7 for electrical hookup Sealing Pipe Joints Use only PTFE pipe thread sealant tape for making all threaded connections to the pump itself Do not use pipe joint compounds on plastic pumps they can react with the plastic in pump components Make sure that all pipe joints in the suction pipe are air tight as well as water tight f the suction pipe can suck air the pump will not be able to pull
20. d tambi n tenga otros derechos que pueden variar de un estado al otro Esta Garant a Limitada entra en vigor el 1 de junio de 2011 y sustituye toda garant a sin fecha o garant a con fecha anterior al 1 de junio de 2011 STA RITE INDUSTRIES 293 Wright Street Delavan WI U S A 53115 Tel fono 1 888 782 7483 Fax 1 800 426 9446 Sitio Web sta rite com Instalaci n Al sistema dom stico de agua Te de cebadura de la e bomba con tap n T y tap n para cebar V lvula check Punto de hincar CH debajo del nivel T71 del agua I5 Reemplazo de una bomba vieja A ADVERTENCIA Voltaje peligroso Desconecte la alimentaci n de energ a de la de hincar Punto de Ilustraci n de una hincar amp bomba t pica n No est a Escala Figura Instalaci n del Punto de Hincar Al sistema we dom stico de agua E Te de cebadura de la bomba con tap n o man metro Tuber a de succi n del pozo para cebar Sello sanitario del pozo Por lo V lvula de menos 10 Retenci n DN Figure 2 Instalaci n para pozo recubierto bomba antes de trabajar en ella o en el motor 1 Drene y quite la bomba vieja Revise la tuber a vieja por si estuviera oxidada tuviera cal o moho etc y reempl cela si es necesario 2 Instale la bomba en el sistema Aseg rese de que todas l
21. dos por debajo de la cubierta del motor deber n ser similares a los que se ilustran a continuaci n Utilice las instrucciones para configurar su motor conforme a su suministro de energ a A ADVERTENCIA Nunca conecte un motor configurado a 115 V a una fuente de energ a de 230 V Selector de tensi n de tipo ficha La configuraci n es para 230 V Para cambiar a 115 V Conexiones de alimentaci n E 6 Conexi n del cable a tierra Interruptor de Presi n Figura 6 Tensi n configurada para 230 Y tipo ficha 1 Verifique que la corriente el ctrica est desconectada 2 Jale de la ficha de cambio de tensi n y s quela de las leng etas 3 Muewa la ficha de cambio de tensi n a la posici n de 115 V Ahora la ficha cubrir 2 leng etas met licas y la flecha en la ficha quedar alineada con la flecha de 115 V en la etiqueta consulte la Figura 7 A Figura 7 Tensi n configurada para 115 V tipo ficha 4 Conecte los conductores de alimentaci n a los dos tornillos exteriores en el man stato seg n se ilustra en el Figura 6 5 Conecte el cable a tierra a una de las conexiones a tierra seg n se ilustra en la Figura 6 6 Si hay otros cables t pelos 7 Vuelva a instalar la cubierta del motor Selector de tensi n de tipo cuadrante La configuraci n de f brica es para 230 V Para cambiar a 115 V Conexiones de alimentaci n Cuadrante de cambio de EB tensi n Figura 8 Tensi n co
22. eben estar protegidos por rel s de sobrecarga de disparo extra r pido con compensaci n ambiental de tres etapas del tama o recomendado de lo contrario la garant a quedar anulada Su nico recurso y la nica obligaci n de STA RITE es que STA RITE repare o reemplace los productos defectuosos a juicio de STA RITE Usted deber pagar todos los cargos de mano de obra y de env o asociados con esta garant a y deber solicitar el servicio bajo garant a a trav s del concesionario instalador tan pronto como se descubra un problema No se aceptar ninguna solicitud de servicio bajo garant a que se reciba despu s del vencimiento del Per odo de Garant a Esta garant a no se puede transferir STA RITE NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCIDENTAL O CONTINGENTE LAS GARANT AS LIMITADAS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA E IMPL CITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO LAS GARANT AS LIMITADAS QUE ANTECEDEN NO SE EXTENDER N M S ALL DEL PER ODO DE DURACI N INDICADO EN LA PRESENTE Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que uste
23. erra suministrado por la empresa de energ a o hidroel ctrica 4 Conecte los alambres de suministro de corriente al conmutador de presi n seg n se ilustra en la Figura 6 Usted acaba de realizar las conexiones el ctricas para su bomba Por favor pase a la p gina 20 a las preparaciones para arrancar la bomba Tabla de conexiones Cables recomendados y Tama os de fusibles Amp de Distancia en pies desde el motor al suministro de energia Amp de Rango de 51 100 101 200 201 300 301 400 401 500 Carga Fusible de HP del Motor Voltios M xima Derivaci n Calibre del cable awg mm cuadrados Preparaci n para arrancar la bomba Pozo profundo 20 1866 0111 Figura 8 Llenado de la bomba AVISO La bomba y la tuber a se da ar n si se congelan y no se han drenado Siga las instrucciones de preparaci n para el invierno Cebado A ADVERTENCIA Nunca ponga a funcionar una bomba hacia una descarga cerrada Hacerlo puede ocasionar que el agua en el interior de la bomba ebullicione produciendo una presi n peligrosa en la unidad riesgo de explosi n y posibles quemaduras con el agua a la persona que est manejando la bomba A PRECAUCI N Nunca ponga a funcionar la bomba en seco Poner a funcionar la bomba sin agua puede ocasionarle sobre calentamiento dafiar el sello y tal vez causar quemaduras a las personas que la est n manejando Llene la bomba con agua antes de arr
24. h all local codes and ordinances that apply Consult your local building inspector for code information Connection Procedure 1 Connect the ground wire first as shown in Figure 6 The ground wire must be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal connection between the pressure switch and the motor for motor grounding protection If the pressure switch is not connected to the motor connect the green ground screw in the switch to the green ground screw under the motor end cover Use a solid copper wire at least as large as the power supply wires 3 Connect the ground wire to a grounded lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3 m long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 6 You have just completed the wiring for your pump Please go to Page 9 for startup preparations Wiring Chart Recommended Wire and Fuse Sizes DISTANCE IN FEET FROM MOTOR TO SUPPLY Mata l Bridifie 51 100 101 200 201 300 301 400 401 500 Motor HP Volts PAW RESIZE mm OO Amp Rating Amp AWG WIRE SIZE mm 115 230 12 2 6 1 14 14 2 2 14140 1014 2 8 14 7 2 8 14 7 2 6 12 9 3 Preparing to Start the Pump 1866 0111 Figure 10 Prime the Pump NOTICE Pump and piping will be damaged if fro
25. hs from date of original installation or Sump Sewage Effluent Products 18 months from date of manufacture Our warranty will not apply to any product that in our sole judgement has been subject to negligence misapplication improper installation or improper maintenance Without limiting the foregoing operating a three phase motor with single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and STA RITE s only duty is that STA RITE repair or replace defective products at STA RITE s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferable STA RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or con
26. ione todas las conexiones en la l nea de aspiraci n y en el sello del eje 2 Baje la l nea de aspiraci n hacia el agua y vuelva a cebar Si la disminuci n el nivel de agua supera los 25 pies 7 6 m ser necesario instalar una bomba para pozo profundo La v lvula de pie o el colector est n tapados Limpie la v lvula de pie o el colector El eyector o el impulsor est n tapados Limpie el eyector o el impulsor La v lvula de retenci n o la v lvula de pie est cerrada y atascada Reemplace la v lvula de retenci n o la v lvula de pie Las tuber as est n congeladas Descongele las tuber as Entierre las tuber as debajo de la l nea de congelaci n Caliente el recinto de bombas o el foso Eleve la v lvula de pie y o el colector por encima del fondo de la fuente de agua Limpie la v lvula de pie y el colector La v lvula de pie y o el colector est n enterrados en arena o en lodo oco profun nivel de agua es demasiado bajo para que la instalaci n del pozo o produzca agua Se necesitar un paquete de chorro para pozo profundo si su pozo tiene m s de 25 pies 7 6 m de profundidad al agua El nivel del agua en el pozo profundo es menor que el que se calcul Es posible que se requiera una nueva combinaci n de venturi y tobera La tuber a de acero si se utiliz est corro da u oxidada Reemplace con tuber a de pl stico donde sea posible o de lo contrario con tuber a nueva de acero ocasionando una fricci
27. lt Z O g s ceisle ol ols 2 zi l9 SIN 32 5 35 lu gns 2 leol2 e ls lt S lo DPlols lo cle lg j l ll AITIS a o gt 2 PS w e Seal and Gasket Kit PNCSS uses a 1 4 NPT Plug Part No WC78 40T Repair Parts 12 Exploded View FSN Series 1 2 3 4 HP FNC L 1 2 HP FND L 3 4 HP FSN Series 1 2 3 4 HP Part Description Qty Model and Horsepower Ma IEA 1 2 HP 3 4 HP 1 2 HP o mue pa me p mee meam as ter 3 we ex e rampa na e rear p Nes L5 oe AOS IAE CT TAC at eo e a aa ore es o S e IU EII AE AE FND L uses Pump Body Assembly No N176 38FF Seguridad Instrucciones importantes de seguridad Guarde estas instrucciones Este manual contiene instrucciones importantes que se deben seguir durante la instalaci n y el mantenimiento del bombas de sumidero A Este es un s mbolo de alerta sobre la seguridad Cuando vea este s mbolo en su bomba o en este manual busque para ver si hay alguna de las siguientes palabras de se al y est alerta a la posibilidad de lesiones personales indica un riesgo que de no evitarse provocar la muerte o lesiones de gravedad A ADVERTENCIA indica un riesgo que de no evitarse podr a provocar la muerte o lesiones de gravedad A PRECAUCI N indica un riesgo que de no evitarse podr a provocar lesiones leves o moderadas AVISO hace referencia a una pr
28. n Eee ESI EE ur Cel 3 10 Tap n del tubo U78 941ZPV U78 941ZPV U78 941ZPV Junta arponada 1 4 NPT U111 211T U111 211T U111 211T Codo arponado 1 4 NPT U111 212T U111 212T U Tubo de 3 8 O D x 14 1 2 de largo U37 672P Tornillo de cabeza hexagonal 3 8 16x1 1 4 de largo m emaxegeed O O hee FND L utilice Ensamble del cuerpo de la bomba no N176 38FF U217 1225 U217 1225 U217 1202 U36 112ZP 36 112ZP U36 112ZP L43 5C L43 5C L43 5C U30 75ZP U30 75ZP U30 75ZP PP1560 PP1561 N A FPP1550 P2 FPP1550 P2 FPP1550 P2 N3 1043P N3 1043P N3 1043P
29. nd Drain tank to air volume control port Check AVC for defects Check all has no air cushion connections for air leaks Pipes leak Check connections Foot valve leaks Replace foot valve Pressure switch is out of adjustment Adjust or replace pressure switch Air charge too low in pre charged tank DISCONNECT POWER and open faucets until all pressure is relieved Using tire pressure gauge check air pressure in tank at valve stem located on the tank If less than pressure switch cut in setting 30 50 PSI pump air into tank from outside source until air pressure is 2 PSI less than cut in setting of switch Check air valve for leaks use soapy solution and replace core if necessary Air spurts from faucets Pump is picking up prime When pump has picked up prime it should pump solid water with no air Leak in suction side of pump Suction pipe is sucking air Check joints for leaks with soapy water Well is gaseous Consult factory about installing a sleeve in the well Intermittent over pumping of well Water Lower foot valve if possible otherwise restrict pump discharge drawn down below foot valve Repair Parts E Exploded View PN Series 1 3 thru 3 4 HP PNCSS 1 2 HP PN Series 1 3 thru 3 4 HP Model PNCSS 1 2 HP Model and Horsepower 115V 1 3 HP 115 230V 1 2 HP 115 230V 3 4 HP 115 230V 1 2 HP Part Description Qty PNB 1L PNC 1L PND 1L PNCSS J218 577 PKG 218 582A 115 PKG 218 590 PKG J
30. nfigurada para 230 V tipo cuadrante 1 Verifique que la corriente el ctrica est desconectada 2 Gire el cuadrante hacia la izquierda hasta que aparezca 115 en la ventana del cuadrante seg n se ilustra en la Fig 7 1 Figura 9 Tensi n configurada para 115 V tipo cuadrante 3 Conecte los conductores de alimentaci n a los dos tornillos exteriores en el man stato seg n se ilustra en el Figura 6 4 Conecte el cable a tierra a una de las conexiones a tierra seg n se ilustra en la Figura 6 5 Si hay otros cables t pelos 6 Vuelva a instalar la cubierta del motor Electricidad 19 A ADVERTENCIA Tensi n peligrosa Puede causar choques quemaduras o muerte Conecte el alambre de puesta a tierra antes de conectar los alambres de suministro de corriente Use el cable del tama o especificado en la tabla de cableado incluyendo el alambre de puesta a tierra Si es posible conecte la bomba a un circuito separado de derivaci n sin ning n otro artefacto en el mismo A ADVERTENCIA Peligro de explosi n No haga la conexi n a tierra en una l nea de suministro de gas Conexiones de los cables A ADVERTENCIA Peligro de incendio Una tensi n incorrecta puede causar un incendio o dafiar el motor seriamente e invalidar la garant a La tensi n de suministro debe ser entre 10 de la tensi n especificada en la placa de datos del motor AVISO Los motores de doble tensi n se pueden configurar par
31. ng plug and suction pipe to the pump see Figure 3 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pipe thread sealant tape Joints must be air and water tight If the suction pipe can suck air the pump cannot pull water from the well You have just completed the plumbing for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections Discharge Pipe and Pressure Tank Connections 6 To Household we Water System Pump Priming Tee with Plug Y 24 or Gauge Ea Pressure Switch From Well Figure 4 Pre charged Tank Connections e To Household Water System 6 Air Volume Control Pump Priming Tee with Plug or Gauge Air Volume Control Tube Pressure Switch Figure 5 Standard Tank Connections Pre Charge Tank Connection Figure 4 1 Install two tees in the pump discharge port see Figure 4 The pipe size must be at least as large as the discharge port Run a pipe or reinforced hose from one arm of the first tee to the port on the pre charged tank Connect the other end of the discharge tee to your plumbing system Cap the tee with a threaded plug or a pressure gauge Check the pre charge of air in the tank with an ordinary tire g
32. nt a 14 Guarde el recibo original para culaquier referencia posterior Garant a limitada STA RITE le garantiza al comprador consumidor original Comprador o Usted de los productos enumerados abajo que estos estar n libres de defectos en material y mano de obra durante el Per odo de garant a indicado a continuaci n Producto Per odo de garant a lo que ocurra primero 12 meses desde la fecha de la instalaci n o 18 meses desde la fecha de fabricaci n Productos de sistemas de agua bombas de chorro peque as bombas centr fugas bombas sumergibles inicial o y accesorios asociados Tanques de compuesto Pro Source 5 a os desde la fecha de la instalaci n inicial Tanques a presi n de acero Pro Source 5 a os desde la fecha de la instalaci n inicial Tanques con revestimiento epox dico Pro Source 3 a os desde la fecha de la instalaci n inicial 12 meses desde la fecha de la instalaci n inicial o Productos para sumideros aguas residuales efluente 18 meses desde lara detecci n Nuestra garant a no se aplicar a ning n producto que a nuestro s lo juicio haya sido sometido a negligencia mal uso instalaci n inadecuada o mal mantenimiento Sin prejuicio a lo que antecede la garant a quedar anulada en el caso en que un motor trif sico se haya usado con una fuente de alimentaci n monof sica a trav s de un convertidor de fase Es importante indicador que los motores trif sicos d
33. on port on the pump Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pipe thread sealant tape Joints must be air and water tight If the suction pipe can suck air the pump cannot pull water from the well You have just completed the suction piping for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections Installation for Surface Water Figure 3 A CAUTION Possible contamination Do not use surface water for drinking The installation shown could be used for sprinkler applications 1 The pump should be installed as close to the water as possible with the fewest possible fittings especially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump Assemble a foot valve and suction pipe see Figure 3 Make sure that the foot valve works freely Use PTFE pipe thread sealant tape on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it see Figure 3 Lower the pipe into the water until the strainer is five feet above the bottom It should also be at least 10 feet below the water level in order to prevent the pump from sucking air Install a priming tee primi
34. pe thread sealant tape Joints must be air and water tight If the suction pipe can suck air the pump cannot pull water from the well If one well point does not supply enough water consider connecting two or three well points to one suction pipe You have just completed the suction piping for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections Cased Well Installation 2 or Larger Casing Figure 2 Mount the pump as close to the well as possible Assemble the foot valve strainer and well pipe see Figure 2 Make sure that the foot valve works freely Lower the pipe into the well until the strainer is five feet above the bottom of the well It should also be at least 10 feet below the well s water level while the pump is running in order to prevent the pump from sucking air Install a sanitary well seal Installation To Household Pump Priming Water System i A Tee with Plug or Gauge Suction Pipe From Water Priming Tee and Plug 10 Min 5 10 Screen f Figure 3 Surface Water Installation Install a priming tee priming plug and suction pipe to the pump see Figure 2 Connect the pipe from the well to the pump suction port using the fewest possible fittings especially elbows as fittings increase friction in the pipe however include a foot valve see Figure 2 The suction pipe should be at least as large as the sucti
35. que se formen bolsas de aire que pueden bloquear la bomba Sellar las juntas de la tuber a de aspiraci n con cinta selladora de PTFE para roscas de tuber a Las juntas deben ser a prueba de agua o estar herm ticamente cerradas Si la tuber a de succi n pudiera succionar aire la bomba no podr sacar agua del pozo Usted acaba de realizar la conexi n de tuber a de succi n para su nueva bomba tipo jet para pozo poco profundo Por favor pase a la P gina 17 para realizar las conexiones del tanque y de la tuber a de descarga Instalacion para agua superficial Figura 3 A PRECAUCI N No use la capa de agua superficial para beber La instalaci n ilustrada se podr a usar para rociar regar pulverizar T La bomba se debe instalar lo m s cerca del agua que sea posible con el menor n mero posible de conexiones especialmente codos en la tuber a de succi n La tuber a de succi n debe ser por lo menos del mismo tama o que el orificio de succi n de la bomba Instale una v lvula de retenci n y la tuber a de succi n vea la Figura 3 Aseg rese de que la v lvula de retenci n funcione libremente Utilizar cinta selladora de PTFE para roscas de tuber a sobre las juntas roscadas de la tuber a Proteja la conexi n de la v lvula de retenci n de peces basura etc con la instalaci n de una malla de alambre a su alrededor Vea la Figura 3 Baje la tuber a hacia el agua hasta que el filtro se encuentre
36. raci n cerca de la bomba Instale un anillo reductor de hasta 1 8 NPT en la T Instale la tuber a desde la T hasta el orificio del regulador de volumen de aire integrado sobre el tanque Sellar las juntas de la tuber a de aspiraci n con cinta selladora de PTFE para roscas de tuber a Para m s detalles consulte las instrucciones que vienen con el tanque y el regulador de volumen de aire Felicidades Usted acaba de realizar la conexi n del tanque para su bomba tipo jet Por favor pase a la p gina 18 para saber acerca de la conexi n el ctrica Sellado de juntas de tuber a Levar a cabo todas las conexiones roscadas a la bomba utilizando solamente cinta selladora de PTFE para roscas de tuber a No use compuestos de burlete para tuber as en bombas de pl stico estos pueden reaccionar con los componentes de pl stico de la bomba Aseg rese de que todos los burletes en la tuber as de aspiraci n sean impermeables y herm ticos Si la tuber a de aspiraci n aspira aire la bomba no podr sacar agua del pozo Electricidad 18 A Desconecte la corriente antes de trabajar en la bomba el motor el conmutador a presi n o los cables Configuraciones del interruptor del motor AVISO Los motores de 1 2 HP y 1 3 HP son de doble tensi n y est n configurados de f brica a 115V Los motores de 3 4 HP tambi n son de doble tensi n pero vienen configurados de f brica a 230 V Los tableros de bornes del motor ubica
37. rough 1 Re prime according to instructions 1 Improper priming 2 Check all connections on suction line AVC and ejector with soapy water or 2 Air leaks shaving cream Stop pump then check 3 Leaking foot valve or check valve 3 Replace foot valve or check valve prime before looking for other causes Unscrew priming plug and see if water is in priming hole Pump has lost prime through In installation already in use 1 Air leaks 1 Check all connections on suction line and shaft seal 2 Water level below suction pipe inlet 2 Lower suction line into water and re prime If receding water level in well exceeds 25 7 6M a deep well pump is needed Foot valve and or strainer are buried in Raise foot valve and or strainer above bottom of water source Clean foot valve sand or mud and strainer Water level is too low for shallow well A deep well jet will be needed if your well is more than 25 7 6M depth to setup to deliver water water Pump does not deliver water Water level in well is lower than estimated A new nozzle and venturi combination may be needed to full capacity Also check point 3 immediately above Steel piping if used is corroded or limed Replace with plastic pipe where possible otherwise with new steel pipe causing excess friction Pump delivers water but does Pressure switch is out of adjustment or not shut off or pump cycles contacts are welded together Standard pressure tank is waterlogged a
38. sequential damages or limitations on the duration of an implied warranty so the above limitations or exclusions may not apply to You This warranty gives You specific legal rights and You may also have other rights which vary from state to state This Limited Warranty is effective June 1 2011 and replaces all undated warranties and warranties dated before June 1 2011 STA RITE INDUSTRIES 293 Wright Street Delavan WI U S A 53115 Phone 1 888 782 7483 Fax 1 800 426 9446 Web Site sta rite com Installation To Household Water System e u Pump Priming A Tee and Plug Drive point below water level Drive gt Typical pump shown herein Not to Scale Figure l Driven Point Installation To Household vw Water System Pump Priming Tee with Plug Suction Pipe From Well AS Priming Tee and Plug Sanitary Well Seal 10 Foot Min Valve A 5 10 l Figure 2 Cased Well Installation Replacing An Old Pump A WARNING Hazardous voltage Disconnect power to pump before working on pump or motor 1 Drain and remove the old pump Check the old pipe for scale lime rust etc and replace it if necessary Install the pump in the system Make sure that all pipe joints in the suction pipe are air tight as well as water tight If the suction pipe can suck air the pump will not be able to pull water from the well Adjust
39. t operation This will also help clean the system of dirt and scale dislodged during installation Winterizing the Pump To prepare the pump for freezing temperatures js 2 Shut off power to the pump Relieve system pressure Open a faucet and let it drain until water stops flowing Drain the pump Your pump may have a separate drain plug Remove this plug and let it drain Your pump may only have a plug or connection on the side of the pump Remove this and let the pump drain Some water will remain in the pump A small amount of water left in the pump will not harm it if it freezes Troubleshooting 10 Wires at motor are loose disconnected or Refer to instructions on wiring Page 9 DISCONNECT POWER check and wired incorrectly tighten all wiring 44 WARNING Capacitor voltage may be hazardous To discharge capacitor hold insulated handle screwdriver BY THE HANDLE and short capacitor erminals together Do not touch metal screwdriver blade or capacitor terminals If in doubt consult a qualified electrician Pressure switch contacts are dirty DISCONNECT POWER and file contacts with emery board or nail file kigks off Voltage is too low Check with power company Install heavier wiring if wire size is too small See Electrical Wiring Chart Pump cycles too frequently See section below on too frequent cycling Motor runs but no water is Pump in new installation did not pick up In new installation delivered prime th
40. tensi n del capacitor puede ser peligrosa ara descargar el capacitor tome un destornillador con mango aislado POR EL MANGO y haga un corto circuito con los bornes del capacitor No toque la hoja met lica del destornillador ni los bornes del capacitor Si tiene alguna duda consulte con un electricista competente Los contactos del man stato est n sucios DESCONECTE LA CORRIENTE EL CTRICA y lime los contactos con una lima de esmeril o una lima para u as El motor est cableado incorrectamente Consulte las instrucciones sobre el cableado La tensi n es muy baja Verifique con la compa a de energ a el ctrica Instale un cableado de mayor calibre si ste es muy peque o Ver el Gr fico de Cableado Electricidad Los ciclos de la bomba son muy frecuentes Consulte la secci n a continuaci n sobre ciclos demasiado frecuentes La bomba en una instalaci n nueva no recogi el cebado debido a En una instalaci n nueva 1 Cebado inadecuado 1 Vuelva a cebarla seg n las instrucciones 2 Fugas de aire 2 Revise todas las conexiones en la l nea de aspiraci n en el AVC y en el eyector 3 Fugas en la v lvula de pie o en la v lvula de retenci n con agua jabonosa o crema de afeitar 3 Reemplace la v lvula de pie o la v lvula de retenci n La bomba ha perdido cebadura debido a 1 Fugas de aire 2 Nivel de agua por debajo de la entrada de la tuber a de aspiraci n En una instalaci n que ya est en uso 1 Inspecc
41. umen de aire Interruptor de presi n Desde el pozo Figura 5 Conexiones para Tanque Est ndar 17 Conexi n para tanque pre cargado Figura 4 1 Instale dos T s en el puerto de descarga de la bomba Vea la figura 4 El tama o de la bomba debe de ser por lo menos tan grande como el puerto de descarga Instale un tubo o una manguera reforzada desde un brazo de la primera T al puerto en el tanque pre cargado Conecte el otro extremo de la T de descarga a su instalaci n de tuber as Tape el Te con un tap n fileteado o con un man metro Verifique la pre carga de aire en el tanque con un medidor ordinario de aire para neum ticos La pre carga debe ser de 2 PSI menos que el ajuste de cierre del interruptor de presi n de la bomba La pre carga se mide cuando no haya presi n de agua en el tanque Su nueva bomba tiene un interruptor de 30 50 PSI por lo tanto ajuste la presi n de pre carga del tanque a 28 PSI Felicidades Usted acaba de realizar la conexi n del tanque para su bomba tipo jet Por favor pase a la p gina 18 donde se encuentra la secci n sobre la conexi n el ctrica Conexi n para tanque est ndar Figura 5 Te 2 Instale una T en el puerto de descarga de la bomba Fig 5 Ponga una bomba desde el puerto de descarga al puerto de entrada de su tanque El tamafio del tubo debe ser por lo menos tan grande como el puerto de descarga Instale una T en el tubo de aspi
42. zen and not drained Follow winterizing instructions Priming 42 WARNING Explosion hazard Never run pump against closed discharge To do so can boil water inside pump causing hazardous pressure in unit risk of explosion and possibly scalding persons handling pump 4 CAUTION Never run pump dry Running pump without water may cause pump to overheat damaging seal and possibly causing burns to persons handling pump Fill pump with water before starting Tz Remove the priming plug from the pump and fill the pump fill all piping between the pump and the well and make sure that all piping in the well is full If you have also installed a priming tee in the suction piping remove the plug from the tee and fill the suction piping Replace all fill plugs Power on Start the pump If you don t have water after 2 or 3 minutes stop the pump and remove the fill plugs Refill the pump and piping You may have to repeat this several times in order to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime After the pump has built up pressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pressure drops to 30 PSI and stop when pressure reaches 50 PSI Run the pump through one or two complete cycles to verify correc