ICS-480V 4U Industrial Workstation with 8.4” LCD and 14

image

Contents

1. O71 4 9 101 00 177 00 La200l 187 00 La oo Introduction ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual Chapter 2 System Setup 2 1 System Installation WARNING Before starting the installation process be sure to shut down all power from the chassis Do this by turning off the power switch and unplugging the power cord from the power outlet When in doubt consult with an experienced technician 2 1 1 Removing the top cover First remove the chassis cover The top cover is fixed to the chassis by four screws 1 Release four screws on the sliding rail of both sides 2 Lift the cover Figure 2 1 Top Cover System Setup 5 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 1 2 Chassis Front and Rear Sections Face to the front view of ICS 480V you will find a 8 4 TFT display module There is a front door on the left side of the front panel which has 12 function keys and 65 data entry keys on it The front panel switches and I O interface behind the door are used for system reset power switch USB port OSD control and keyboard lock Figure 2 2 Front View 6 System Setup ICS 480V 4U Industrial
2. end with core to the SBC and the other end to the A D board As shown on the Fig ure 2 13 Connect to SBC Connect to A D board Figure 2 12 VGA Figure 2 13 VGA Cable Connection OSD Control 14 System Setup ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots Backplane User s Manual Main Menu Brightness Contrast Horizent Position Vertical Position System Setup 15 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual Appendix Safety Instructions B 1 Safety Instructions 1 Read these safety instructions carefully 2 Keep this User s Manual for later reference 3 Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning 4 For plug in equipment the power outlet socket must be located near the equipment and must be easily accessible 5 Keep this equipment away from humidity 6 Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage 7 The openings on the enclosure are for air convection Protect the equipment from over heating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power source is correct before connecting the equipment to the power outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment Sh
3. pr a gt fr a A Power for System Fan and A D board B Keyboard Transmitter D Power Switch Figure 2 8 Cable Connection System Setup 11 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 3 Power Supply ICS 480V is with a power supply bracket please use this bracket for PS 2 power and remove this bracket if you want to install redundant power supply Figure 2 9 Power 12 System Setup ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 4 Air Filter Replacement There is one Cooling Fans located inside the chassis behind the LCD The Arr Filter is easy to maintain To replace the Air Filter please refer to Figure 2 I 1 a Release the two screws on the Air Filter holder b Take out the Air Filter and replace with the new one d Figure 2 11 Air Filter System Setup 13 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 5 VGA Cable Installation The ICS 480V is an innovation version workstation which supports most Single Board Computer from most IPC vendors AXIOMTEK had integrated the VGA A D board to the ICS 480V As long as the SBC has the industrial standard 9 pin D sub it can be installed in the ICS 480V To connect the VGA Cable a Please take out the VGA Cable as shown in Fig ure 2 12 from the accessory kit b Connect the
4. 1 4 Drive Bay Installation eorronnnrrnnrennnrrnnnennnnvnnnennnnnnnnernnnee 8 2 1 5 CPU card Installation rerorraronrrrarrnrererrnrenvernrvnvernernveneenn 9 2 1 6 Cable connection for CPU card rrrarnrnrnrnrnnnrnnnennnenanenn 10 2 2 Cable Connection for A D Board amp Fan Power Power Switch and Keyboard Control nnnnvnnnnnnnnnnnnnnnnnnnnnen 10 2 9 F R SUDDIY none er epee eee naia 12 2 4 Air Filter Replacement nrrnnnvrnnnnvrnnnuvrnnnnennnnvennnnernnnnuenn 13 2 5 VGA Cable Installation evennnrnnnnernnnnennnnnennnnvennnnnnnnnnnnnn 14 Appendix A Safety Instructions a xxrrvnnnnvevnnnnnvn 17 B 1 Safety Instructions uareanaamnamusmnrsdaemivn 17 Table of Contents ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual Chapter 1 Introduction 1 1 Introduction 4U Industrial workstation with 8 4 LCD amp 14 slots backplane The ICS 480V is a 4U 14 slots Rackmount Workstation with 8 4 LCD display and Front panel function amp data entry keypad This workstation is a full function and cost effective designed Industrial Automation Controller The ICS 480V is available with several combinations of the backplane and power supply which can apply to versatile applications The build in VGA A D board ensures the system compatible with variety of Single Board Computers from most of vendors The front panel OSD controller allows user to tune the LCD into the best p
5. ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane User s Manual li Disclaimers The information in this manual has been carefully checked and is believed to be accurate AXIOMTEK Co Ltd assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use AXIOMTEK assumes no responsibility for any inaccuracies that may be contained in this document AXIOMTEK makes no commitment to update or to keep current the information contained in this manual AXIOMTEK reserves the right to make improvements to this document and or product at any time and without notice No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopy ing recording or otherwise without the prior written permission of AXIOMTEK Co Ltd Copyright 2004 by AXIOMTEK Co Ltd All rights reserved July 2004 Version V1 0 Printed in Taiwan Trademarks Acknowledgments AXIOMTEK is a trademark of AXIOMTEK Co Ltd IBM is a registered trademark of International Business Machines Corporation MS DOS Microsoft C and QuickBasic are trademarks of Microsoft Corporation TURBO C is a trademark of Borland Inc BASIC is a trademark of Dartmouth College Intel is a trademark of Intel Corporation Other brand names and trademarks are the properties and registered brands of their respective o
6. Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 1 3 Front Control System Reset Press this switch to reinitialize the system This is the same as the hardware reset button Power On Off Switch Use this switch to turn on off the system power USB port If you want to connect any USB interface device to the system you could use this Keylock To lock the keyboard control KB MB IN Integrated PS 2 type 6 pin Keyboard and Mouse port PWR HDD Figure 2 3 Front Control System Setup 7 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 1 4 Drive Bay Installation The standard type of the drive bay of ICS 480V can hold up to three external 5 25 devices or two 5 25 and one 3 5 devices and one 3 5 HDD Axiomtek also offer the 5 25 to 3 5 holder GHA FMOI Customer can install this holder on the 5 25 drive bays to get extra 3 5 drive bays 1 Remove the top cover 2 Release the four screws from the top of the Drive Bay Module 3 Lift off the Drive Bay Module 4 Insert the devices into the proper location of the Drive Bay Module and secure them with the screws provided See Figure 2 5 5 Connect the disk drive power and signal cables and re install the Drive Bay Module to the chasses Figure 2 5 Explosive Diagram of Drive Bay 8 System Setup ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 1 5 CPU ca
7. ect ACCESSIBLE METAL PARTS or other PROTECTIVELY EARTHED parts with a protective function to the PROTECTIVE EARTH TERMINAL shall be identified by the colrs green and yellow at lease at the termination of the conductors 17 CAUTION The computer is provided with a Battery powered Real Time Clock Circuit There is a danger of explosion if battery is incorrectly replaced Replace only with same or equivalent typed recommended by the manufacturer Discard use batteries according to the manufacturers instructions Safety Instructions ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 18 The computer is provided with appropriate safety standards including lec 60826 19 Install the computer Before your begin make sure the Green Yellow wire reliable connection between metal part of computer and earthing of final system Safety Instructions 19 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 20 Safety Instructions
8. osition for any environment To enhance the system for easy maintenance and upgrade the two front USB ports 12 function keypad amp 65 data entry keypad have been build in to the front panel The arr filter is located on the external top cover which minimizes the system down time for air filter replacement This ideal industrial grade workstation can be applied to the various of industrial projects such as transportation factory automation environmental surveillance and more Introduction 1 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 1 2 General Specification e Construction Heavy duty steel chassis e Drive bay Shock proof and front accessible 5 25 by three drive bays e Cooling system Single 86 CFM cooling fan with top accessible air filters e Controls Power switch on off or momentary reset switch and keyboard lock behind lockable door e LED Indicator Power and HDD LED for system Power and Hard disk status LED for system power status e Connectors Front accessible USB and PS 2 key board rear panel 9 pin connector 9 pin connec tor are not include in the M B version e Paint Color Black e Operating Temperature 0 50 C 32 F 122 F e Storage Temperature 50 60 C 409F 140 F e Relative Humidity 10 95 40 C non condens ing e Vibration 2G Non operation 1G Operation e Slide rails General Device C 300 series supports e Dimen
9. ould be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety rea sons the equipment should be opened only by qualified service personnel 14 If one of the following situations arises get the equipment checked by service personnel Safety Instructions 17 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 18 a The power cord or plug is damaged b Liquid has penetrated into the equipment c The equipment has been exposed to moisture d The equipment does not work well or you cannot get it to work according to the user s manual e The equipment has been dropped and damaged f The equipment has obvious signs of breakage 15 DO NOT LEAVE THIS EQUIPMENT IN AN ENVI RONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT Th sound pressure level at the operators position according to IEC 704 1 1982 is no more than 70dB A DISCLAIMER This set of instructions is given according to IEC 704 1 AXIOMTEK disclaims all responsibility for the accuracy of any statements contained herein 16 Any insulation on conductors inside EQUIP MENT which conn
10. rd Installation To install slot board computers and other add on boards 1 Remove the chassis cover 2 Take out the hold down cramp 3 Insert the SBC or add on cards on suitable loca tion 4 Before connect system cables to the CPU card please consult the CPU card manual 5 Align and fix the screw to tighten the card to a fixed position Figure 2 6 SBC Hold down Cramp System Setup 9 ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 2 1 6 Cable connection for CPU card There four cables come with the ICS 480 barebone HDD LED Reset Switch Speaker and Keyboard Lock Please refer to your SBC manual to connect these four jumpers to the SBC Figure 2 7 System Cables 2 2 Cable Connection for A D Board amp Fan Power Power Switch and Keyboard Control There is one four pins power connector need to be connected to the power supply to provide power to the A D board and system Fan a This cable should be connected to the system power supply There are three cables needs to be connect to the backplane b Keyboard Transmitter for Front Membrane Keypad amp DIN 5 pin Keyboard port c Rear DIN 5 pin Keyboard Port d Power Switch 10 System Setup ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual C Rear Keyboard i f fm cs ae en 53 P a P s JE oom aa F r oe 7
11. sions 482 6 W x 452 D x 177 H mm 19 x17 8 x7 e Weight 17 21kg e Safety CE compliant for integrated system 2 Introduction ICS 480V 4U Industrial Workstation with 8 4 LCD and 14 slots backplane Users Manual 1 3 Passive Backplane Options e ATX6022 13L 8 ISA 4 PCI 1 PICMG single seg ment e ATX6022 14 9 ISA 4PCI 1 PICMG single seg ment e ATX6022 14G 1 ISA 12 PCI 1 PICMG single segment e ATX6020 14 14 ISA single segment e For Manuals of above backplanes please refer to http www axiomtek com tw support php 1 4 Power Supply Options Specification Model name Watt Input Output Mini load Safety MTBF CWT 9300TC2 300W 115 230Vac 12VQ10A 5SV Q5A SA UL60 hours 25 AT Selectable 12V I1A 12V 2A 950 2nd CE fall loadSS 5V 1A TUV CB a 5V 30A UL cUL C 3 3V 28A SA CE gt 50 000 SS 300FS 300W 90 264Vac 12V Q15A 5V 2A EN61000 3 3 hours 25 ATXw PFC Fullrange 12V 0 8A 12V 1A Class wio FAN 5V 0 5A DTUV PFC 5Vsb 2A CB 5V 30A CWT 300 115 230Vac 12V QISA 3 3V 0 5A TUV EG ATX12 ATX oe Selectable 12V Q0 5A 12V 0 5A peewee a 5V 0 5A 5VSB 0 2A 5VSB 2A 5V 30A SNP 425C DC48 40VDC 12V 12A AT 250W pa 5V 2A SV IA UL CSA CE 12V 2A Introduction ICS 480V 4U Industrid Workstation with 8 4 LCD and 14 slots backplane User s Manual 1 5 Dimensions 7
12. wners iii iv ESD Precautions Integrated circuits on computer boards are sensitive to static electricity To avoid damaging chips from electrostatic discharge observe the following precautions E Do not remove boards or integrated circuits from their anti static packaging until you are ready to install them E Before handling a board or integrated circuit touch an unpainted portion of the system unit chassis for a few seconds This helps to discharge any static electricity on your body E Wear a wrist grounding strap available from most electronic component stores when handling boards and components What To Do If There Is A Problem If there are damaged or missing parts contact your supplier and or dealer immediately Do not attempt to apply power to the board if there is damage to any of its components Chapter 1 Introduction rnnnnnnnnnnnnnnnnnnnnnnennnnnnnnn 1 No 1 1 2 General Specification rnnnnnnnnnnnnnnnennnnnnneennnnnnnnnnnnnnnnunnr 2 1 3 Passive Backplane Options rrnnnnnnrnnnnnnvevennnnnnernnnnnnunner 3 1 4 Power Supply Options ssnnxernnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnn 3 1 5 IE REE EE EE 4 Chapter 2 System Setup ernnnnnnnnnnnnnennnnnnnennnnnnunn 5 2 1 System Installation vasene enke 5 2 1 1 Removing the top cover rannnrrnnnennnrrnnnennnrrnnnennnnnnnnennnnen 5 2 1 2 Chassis Front and Rear Sections rrrurrnrrrnnrrnnrrnervnnnnnn 6 2 1 3 Front Control EE EE 2

Download Pdf Manuals

image

Related Search

Related Contents

  NORME DI SICUREZZA SUGLI APPARECCHI SAFETY  PathHunter® eXpress Activated GPCR Internalization Assays  TrafficMASTER 449919 Use and Care Manual  Thermostatic mixer shower with diverter Installation    Hall Aquastyle installation and user manual  Franklin Rolodex RFPC-06 User's Manual  680/15 - 686/15 NL - België Gebruiksaanwijzing en  ご使用前に必ずお読み下さい  