Home

400-230-000-C (PB112-12VDC) ENG.fm

image

Contents

1. Sensor TH11X A F AF 12 VDC TH113 A F AF 12 VDC TH114 A F AF 12 VDC TH115 A F AF 12 VDC TH116 A F AF 12 VDC O O O CESAS 1 2 3 4 1 2 3 4 SS E tof I tot GQ G Gp D oOo gf zZz D N Z Z J b 2 oO VU oO O m g m i 2 CT230 XXXXX CT230 120GA CT230 120GB CT230 240GA CT230 240GB an9 JA40 IMN 400 230 000 C ano gt 5 12 05 1 2 3 3 Master Thermostat Installation and Wiring WARNING Make sure all slave units are in STANDBY mode Required parts TH113 A F AF 12VDC TH114 A F AF 12VDC TH115 A F AF 12VDC or TH116 A F AF 12VDC Location anywhere easily accessible to users Temperature control AF ambient with floor limit A ambient e Install the master thermostat in the controlled area e Choose a location about 5 ft above the floor in an area where the tempera ture is stable e Avoid locations where there are air drafts top of staircase air outlet dead air spots behind a door direct sunlight or concealed chimneys or stove pipes Temperature control F floor Can be installed anywhere Wire the 12 VDC base to the nearest slave unit The floor sensor must be installed in an area where average temperature can be read The cable must follow the wall down to the floor and must not cross any heater wires or be directly on or adjacent to a heating wire For maximum performance the sensor probe should be
2. C TH115 A F AF 12VDC TH116 A F AF 12VDC SLAVE UNITS CT230 120GA CT230 120GB CT230 240GA CT230 240GB The slave units can operate on different voltages e g 5 units 120 V and 5 240 V e Required parts CT230 120GA 120GB 240GA or 240GB Installation On an electrical box e Location Installation near the master thermostat is not required i e can be installed in a utility room e Wiring The power bases are joined through a daisy chain connection Connect the 120 V or 240 V power base wires to the power line and to the load floor using solderless con nectors for copper wires and secure the base to the electrical box Affix the wiring sticker in the CT230 box to the base Connect the slave power bases together as per FIGURE 1 Once installation and wiring is com plete mount the CT230 interface a Align the bracket tabs of the CT230 with the holes located on top of the power base b Secure the CT230 interface using the screw captive POWER Switch all slave power bases to STANDBY by sliding the protective door upwards and positioning the switch to STANDBY Install and connect the master unit see 3 3 UP TO 10 ey 12 VDC 12 VDC FIGURE 1 pave DRIVE Connections enn lo GND Q gt
3. aube technologies by par Honeywell 1 Introduction This master and slave unit system is specially designed for large floor heating applications exceeding 15 A The master thermostat controls a single or multiple floor heating zones driven by slave units The master thermostat can control up to 10 slave units Each slave unit drives its own zone and is equipped with a GFCI test button and warning light as well as an On Standby switch to facilitate maintenance on specific zones of the floor installation 2 Operation Master Thermostat The master unit controls the temperature and sends a signal to slave units when heating is required The floor sensor is connected to the master unit The master unit is powered by the slave units Slave Unit The slave unit receives the signal sent by the master unit and activates its load NOTE There must be a minimum of one slave unit ON to power the master unit 3 Installation Turn off power to the heating system at the main power panel to avoid electrical shock Installation should be carried out by an electrician 3 1 Wiring Guidelines The wire distance between the master thermo stat and slave unit should not exceed 500 ft 150 m e The floor sensor cable should not exceed 200 ft 60 m A 3 wire 20 AWG cable is recommended 3 2 Slave Units Installation and Wiring Installation Instructions MASTER THERMOSTATS TH113 A F AF 12VDC TH114 A F AF 12VD
4. centered between the wires in the mat max 80 C Push the excess wire into the wall secure the base using the provided screws and wall anchors and install the TH11x thermostat onto the base Once the thermostat is installed return power to heating system and switch all slave units and the master thermostat to ON 3 4 Slave Units GFCI Test We recommend you test the GFCI immediately after installing the thermostat and once a month thereafter to ensure it is operating properly If the test warning light comes ON during normal operation cut power to heating system from the main power panel and verify the installation Slide the protective door upwards and make sure the switch is ON Press TEST e The test is successful if the TEST warning light is ON and power is cut off e Ifthe test fails first installation test a Verify installation b Check the load wires c Once you ve identified the problem run the GFCI test again e Ifthe test fails monthly maintenance a Cut power to heating system from the main power panel and call customer service When the test is successful reset the slave unit by switching from ON to STANDBY then back to ON Repeat steps 1 to 3 for all slave units Technical Specifications Temperature Operation 32 F to 122 F 0 C to 50 C Storage 4 F to 122 F 20 C to 50 C TH113 TH114 TH115 TH116 A F AF 12VDC Power
5. domly damaged following installation This warranty cancels and replaces any other manufacturer s express or implied warranty as well as any other company commitment AUBE Technologies Inc cannot be held liable for related or random damages following the installation of this product The defective product as well as the purchase invoice must be returned to the place of purchase or mailed prepaid and insured to the following address Aube Technologies Inc 705 Montrichard Saint Jean sur Richelieu Quebec Canada J2X 5K8 400 230 000 C 5 12 05 2 2
6. supply 12 V from remote unit Maximum up to 10 slave units per slave units master thermostat Wire gauge 20 AWG Size H W D BASE 4 63 x 2 7 x 0 61 in 117 5 x 68 3 x 15 mm NOTE Refer to the TH11x user guide for techni cal specifications CT230 120GA 120GB 240GA 240GB Supply PB112 120 1800 W 120 VAC 60 Hz 15 A resistive PB112 240 3600 W 240 VAC 60 Hz 15 A resistive GFCI GA 5 mA GB 30 mA Certification c CSA us Size H W D BASE 4 63 x 2 7 x 1 45 in 117 5 x 68 3 x 37 mm Size H W D INTERFACE 4 67 x 2 74 x 0 67 in 118 6 x 69 6 x 17 mm Service If you have any questions concerning the installation of the master thermostat or slave units contact our technical support team at Montreal area 450 358 4600 Canada U S 1 800 831 AUBE 2823 Fax 450 358 4650 Email service aubetech com Monday to Friday from 8 30 AM to 5 00 PM EST For more information on our products visit us at www aubetech com Warranty AUBE TECHNOLOGIES INC ONE 1 YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase During this period AUBE Technologies Inc will repair or replace at our option and without charge any defective product which has been used under normal conditions The warranty does not cover delivery costs and does not apply to products poorly installed or ran

Download Pdf Manuals

image

Related Search

Related Contents

One Stop Systems OSS-PCIE-HIB25-X1-H  Samsung SGH-D848 User Manual  Règlement de l`étude CIM Out of Home  Severin SA2964 sandwich maker  Philips HT53365 User's Manual  Guida all`installazione rapida  a la Sigatoka Negra (Mycosphaerella fijiensis  ITA-MANUALE UTENTE WEB CRS5-6  Harman Kardon SB 30 User's Manual  Ver.4.60  

Copyright © All rights reserved.
Failed to retrieve file