Home

DIVA8 SYSTEM User Manual

image

Contents

1. 250 14 4 The TCP IP connection between computer and DIVA8 can t be 250 14 5 No Audio is coming out of speaker 5 222 2 2 2 2 5555555552 250 14 6 Fault List and maintenance operation 250 LEM LCD 77070 8 7 ee ee ee rr 259 16 Safety orco i a a ca ee aaa Beale 261 17 International sales and service points eere 263 www ateis europe com Page 5 of 260 www ateis europe com DIVA8 SYSTEM Page 6 of 260 DIVA8 SYSTEM 1 Welcome MAJ gt DN DELIVERING YOUR MESSAGE Thank you for choosing ATEIS DIVA8M We at ATEIS hope you will enjoy to use this exciting piece of technology as much as we enjoy developing and building it This Help file Manual version is Ver EN 3 1 This files has been written for the ATEIS DIVA software version VER 3 0 0 8 and higher This manual is intended to provide users the necessary understanding to safely uses DIVA8 system as well as guide users through all configuration procedures This manual can be updated at any time without prior notice in order to keep this manual up to date In
2. 41 adds Eveil E ua t oe iiu vo f a leases EL Rx DP maa 41 a L4 FHODCOODEE RT DUE Pao adc dcc reas ro eod ba ei stai eon occa loas secca a a CAFE oL Cu P ded 41 8 3 Messages and Microphone Calls 48 TO Zossen aoaia 52 9 1 Set Computer Network 5 5 55555 55555552555555555555555552 53 9 2 Configure Network OBNGINS 1 c2 ccsnscncasessctiessssanccierconsnsnsnnnnsscesssesaassanecsssnnsbbossbvascsessedenceenbeandiuscaustvens 55 ERREUR 55 Sat Ip NEI SS 58 EPEE A ee A r E E E E 60 9 0 Change Color Schele aadA cun enn neu Rau AN DERE Rx PARLA DK 61 29 Set p System ODIO settore tisse sen Estee se Aaaa 65 9 10 Use thie User managenve E ED MES 66 CM PO COUN a 67 9 19 Add DIVASS RR 81 9 20 Set Speaker Parameters Setting iisisti iniisa iadaaa 83 2 21 SET Power 1 84 2922 Add Messages Info DIM
3. DIVA8 SYSTEM Startup View Elements 1 Title Bar Displays the path name of the active file 2 Menu Bar Holds the main menu commands arranged into functionality groups 3 Toolbars Toolbar items act like a shortcut to their corresponding menu command 4 Tab Bar Shows the window title of all open design and component control windows for quick access 5 Design _ComponentHolds all design component libraries Section 6 Design View Area This area is your work space showing all design windows and component control windows 7 Property ControlThis section slides up for System Status LED Display Section 8 Status Bar Displays useful status communication and compiler information 6 1 Title Bar The title bar displays DIVA Untitled if you start a new system design or the full path name of the saved file At the right hand corner you can find the usual Windows minimize button and the close box which exit the program DIVA Untitled diva 6 2 Main Menu Bar File Edit View User Operation Tools Lock Window Help The main menu bar contains the following menus o pe Co en 6 2 1 File In this paragraph you will find everything related to system files as well as printing command All the DIVA files are saved under the diva extension www ateis europe com Page 28 of 260 New Opens a new system file Save Saves the current s
4. DIVA8 SYSTEM 8 Front Panel Operations This chapter will lead you through the different operations that could be achieved form the front panel configuration changes audio sources level adjustments music sources routing and message triggering In order to keep things clear this chapter will be divided in three main parts e Menu e Managing Music Sources e Messages and Microphone Call In Menus chapter will explain the procedure to enter and to access different settings from the menu navigation Managing Music Sources chapter will lead you through the music routing manipulation Messages and Microphone call will focus on how to start messages and microphone call from the front panel Display Hierarchy The DIVA system display is hierarchically organized as follow from lowest to highest priority 1 Quiescent state no audio is activated 2 Normal state non evacuation audio is activated on the system 3 Fault state any fault status is detected on the system 4 Evacuation state a evacuation state is activated on the system Displays 2 3 and 4 are active for the entire duration of corresponding state Note In quiescent mode DIVA displays the date and time All the LCD strings are listed and described in the LCD Messages List chapter Some operation from the front panel required an higher level than level 1 in that case you will have to enter a valid user name and password Please check the user
5. DIVA8 SYSTEM INTERNAL FAULTS 0x0004 Wk MESSAGE SIZE 0x0005 Name 00010 FADS7830 Evac Input o O ENS NN NEN pes Number of existing message 15 MESSAGE NAME Description 0 15 Audio message 1 255 16 ASCIl MESSAGE FAULT Description 1 15 Audio messages fault 1 255 0 normal 1 fault MESSAGE LEVEL Description 1 15 Audio message level 1 255 www ateis europe com Page 228 of 260 DIVA8 SYSTEM LOGIC INPUTS STATE 0x09FC 0x0A03 Address Bit 1 15 0x0001 0x8000 E tee Tage met dede 0x0001 0x8000 0x0001 0x8000 0x0001 0x8000 1 1 1 Ox0A00 0x0001 0x8000 Ox0A01 0x0001 0x8000 Ox0A02 0x0001 0x8000 Bit field inputs logic input 113 128 0x0001 0x8000 0 Normal 1 Trigger AUDIO INPUTS DETECTION STATES 0x0A04 Description oxooot MIC LINE Input 0x0002 MUSIC 1 Input 0x0003 MUSIC 2 Input EVACUATION INPUT STATES 0x0A05 0x0A0D 0x0001 0x8000 Bit field evacuation inputs Bit 0x0001 0x8000 field _ evacuation inputs 79 112 0x0001 0x8000 field _ evacuation inputs 113 128 i field evacuation inputs 129 144 0 Normal 1 Trigger ES ee 0x0001 0x8000 eld outputs 1 16 0x0001 0x8000 INR outputs www ateis europe com Page 229 of 260 DIVA8 SYSTEM 0x0001 0x8000 logic outputs 0x0001 0x8000 jm outputs
6. DIVA8 SYSTEM 9 13 3 Update PSSG2 Update Slave Update PSS Update PSM Update Ethemet PSS Update File Path Ic Program Files ATEISSDIVA v2 0 0 25 pss_update Open Here you can specify the path of the PSSG2 update file By default the path specified correspond to the software release version Update will start the update process Close closes the window Timeline display shows the update process progression General Display displays the update information 9 13 4 Update PSM CD16 Update Slave Update 55 Update Ethemet PSS Update File Path C Program Files ATEISSDIVA 2 0 0 25 psm_update unite i coe Open Here you can specify the path of the PSM CD16 update file By default the specified path corresponds www ateis europe com Page 74 of 260 DIVA8 SYSTEM to the software release version Update will start the update process Close closes the window Timeline display shows the update process progression General Display displays the update information 9 13 5 Update PSSG2 E Update Slave Update PSS Update PSM Update File Path Open Ic Program Files 4TEIS DIVA v2 0 0 25 e pss update Update Close GroupIP_ _ Status 192 168 10 205 233 211 34 32 0 Open Here you can specify the path of the PSSG2 E update file By default the path specified correspond to the software release version Upd
7. DS T4 T5 ES T7 T7 Conflict Cancel All Coexist Pre Chime Pre Chime Enable Post Chime _ Post Chime Enable Pre define Zone Pre define Zone Enable Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current on is finished www ateis europe com Page 144 of 260 DIVA8 SYSTEM Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones To learn
8. L oj Lo T LS L Figure 2 Chronogram for Cancel All mode for 2 common zone Special case 3 events Figure 3 In coexist mode Event 1 priority 20 zone 1 and 2 coexist mode triggered by logic in Event 2 priority 10 zone 2 3 and 4 coexist mode triggered by logic in Event 3 priority 1 zone 3 and 4 conflict mode whatever Fireman microphone Figure 4 in Cancel All mode Event 1 priority 20 zone 1 and 2 Cancel All mode triggered by logic in Event 2 priority 10 zone 2 3 and 4 Cancel All mode triggered by logic in Event 3 priority 1 zone 3 and 4 conflict mode whatever Fireman microphone Eni Ove Event X J Event 3 O STI ee Zone 1 J LE Il Zone 2 _ D P o o LL LLL 2 4 _ www ateis europe com Figure 3 Chronogram with 3 events in coexist mode Page 241 of 260 DIVA8 SYSTEM Enim Event M NN LLL Event 3 LI 04 41 Letty awa e zmes Figure 4 Chronogram with 3 events in Cancel All mode www ateis europe com Page 242 of 260 DIVA8 SYSTEM 13 Log File Messages List Slave Disconnect 501 DISCONNECT Slave 01 Disconnect 515 DISCONNECT Slave 15 Disconnect 1 V AMP FAIL Master Voice Amp Fail S01 V AMP FAIL Slave 01 Voice Amp Fail 15 V AMP FAIL Slave 15 Voice Amp Fail MO1 V GAIN LOW Master Voice Amp Ga
9. OxOD e End character 2 LF OxOA Transmission from Voice Alarm System to Fire Panel e Start character gt Ox3E e Identifier character I 0x49 e Body of message Sequence of printable characters e character CR 0 The maximum message length including start and end characters is 128 characters www ateis europe com Page 219 of 260 DIVA8 SYSTEM Full duplex mode Transmission from Fire Panel to Voice Alarm System e No echo is expected because of the checksum e Achecksum is included in the message just before the end characters Transmission from Voice Alarm System to Fire Panel Each character sent including start and end characters is echoed by the panel No checksum is expected because of the echo Checksum The checksum is the sum of ASCII codes for all the characters in the message from the identifier character I up to the character immediately preceding the first checksum character inclusive Cyclical communication Voice Alarm System sends the following message to Fire Panel each 30 seconds The Fire Panel answers with the Panel Status Message The bit 2 FAULT is checked by the Voice Alarm System to display the message FIRE PANEL FAULT Request VAS gt P V M 02 CR Response FP gt y PN1 SW4 02 CS2 CR LF With PN1 Panel Number 1 character value 0 SW4 Status Word 4 characters
10. DIVA8 SYSTEM Master 1 All 12 5 6 7 8 From Left to right to down Master 1 correspond to your project name master unit plus slave ones O All selects all zones of master and slave s units Master means master unit O All selects all zone of the master unit 1 8 allows to select independently zone 1 to 8 from a master and or slave unit Cancel All and Coexist options The Cancel All and Coexist options have been created to manage conflict when two events using common zones The higher priority event always overwrites the lowest priority event in the common zone But regarding to the option chosen the behaviour is different To learn more please read this 9 23 2 Event Sequence You can define multiple events by accessing the event window menu View gt Event In this window all the existing events are listed You can add delete events Before adding a new event choose in the Event Type drop down menu the desire event s type Click on the new event then Edit to be able to set up parameters for this new event You can declare event with the same action like playing a message even playing the same message You just have to give them different names The event can be cascaded An explanation diagram is visible on the next figure www ateis europe com Page 92 of 260 DIVA8 SYSTEM An action like closing a contact could induce to star
11. Machine T Music 1 Enable Front Panel Setup Music 2 Enable Mic Line Enable itori Message Enable ee Fireman Enable Ethemet PSSs PSS PSM Enable To access the PSS window simply double click on the PSS icon on the master page In the PSS window you will find two different tabs one for property settings General and one for Keys configuration Key Note PSSg1 and PSSg 2 offer the same setting possibilites in the next chapters PSS name will be used for both microphone For further information on how to use PSS microphones please read the PSS microphone manuals that can be found on the Ateis Europe website 9 27 1 General Page Here is a list of what are the accessible parameters in the General tab Properties Section Name here you can set a name for your PSS Priority here you can set the PSS priority Take care when choosing a priority as the PSS could be a security microphone as well as a evacuation source Access Code you can specify an access code only number in order to be able to use the PSS screen Language allows user to set the PSS screen language between French English Russian Romanian Polish and German www ateis europe com Page 129 of 260 DIVA8 SYSTEM Mic Gain Priority Zero equals highest dB Access Code Digits only Language French hd Mode Selected Messages uc C No Fault Re
12. Next Event None Start Impulse Stop Impulse 2 I3 T4 ES 617 Busy Relay C Enabie 7 DS T4 T5 ES T7 T7 Conflict Cancel All Coexist Pre Chime Pre Chime Enable Post Chime _ Post Chime Enable Pre define Zone Pre define Zone Enable Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished www ateis europe com Page 105 of 260 DIVA8 SYSTEM Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the
13. DIVA8 SYSTEM ATEIS DIVA8 SYSTEM User Manual DIVA8MG2 M S 10UMS01 V01R01 www ateis europe com ATE S Europe BV Sydneystraat 42 3047BP ROTTERDAM NETHERLANDS Phone 31 0 10 2088690 Fax 31 0 10 2088699 P O box 12172 3004 GD ROTTERDAM Chamber of commerce 24465391 Rotterdam www ateis europe com Page 1 of 260 Delivering Your Message DIVA8 SYSTEM Summary 3 Installation Requirements and Hardware 13 2 Hn pec RI sucus caeca bc o dena JJ Lo Cogo cs a Dod dio dud ud dd 13 3 2 EN 54 Installation Redqulremoen s eii iei tania 14 3 9 DIVABM Front VIEW rdi eie Cor dab da 15 Sd DIVASM ROSE VID Rer Cia a sus ba EUR aaa 16 2 0 DIVASS Froni VIBW creen ci hu tisse eere rasa 17 20 DVASS Rear VOW 18 www ateis europe com Page 2 of 260 DIVA8 SYSTEM 1 DN A a ea a eae na 38 S Front Panel ODEFOBON uu aisi bosisind papiru tcabni rbi tu kiki eol Eo imi iE ead a TR RR M d ag e 40 om e RCM E ERREUR 40 a TE a nell cave ne pou DLE dn 41 ds MO i e eO RETRO
14. Event3 Play Message Event 1 Event Event2 _ 1 2 3 Select All Event Type Delete Add j i fe Close Play Message By clicking at the right of the Next Event box you will be able to graphically display the event sequence or loop see below Next Event Event 1 www ateis europe com Page 94 of 260 DIVA8 SYSTEM 9 23 3 Event Type In the Next paragraph you will fin a description of all the different event that could be found in DIVA programming You will by this way learn how to use them and when to use them Load Preset Logic Output Command String Stop Event Stop Zone Play Message Fireman Mic Paging MIC LINE Paging Music ON Music OFF Music ON By Zones Music OFF By Zones Toggle Music ON OFF Toggle Music ON OFF By Zones Security Mode Stop All Event Silence Zone Event 9 23 3 1 Load Preset In DIVA you have the possibility to set preset To learn more about presets please read this The event load preset can be used as soon as there are existing preset It allows activating a preset with different trigger like GPIO or the scheduler Load Preset Event Type Load Preset Priority Not Accessible Name Event 3 Attrib Security Next Event None Preset None Cancel Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Attrib here you
15. Slave Update PSS Update PSM Update Ethernet PSS Update File Path Ic Program Files ATEISSDIVA y2 0 0 25 mcu_update CRC 42739 Update Open Here you can specify the path of the MCU update file By default the path specified correspond to the software release version e CRC displays the CRC check code corresponding to the firmware This CRC code can be compared to the one that can be read from the front panel Update will start the update process Close closes the window Timeline display shows the update process progression General Display displays the update information www ateis europe com Page 72 of 260 DIVA8 SYSTEM 9 13 2 Update Slave Unit Update Update 1 PSS Update PSM Update Ethemet PSS Update Fie Path C Program Files ATEISSDIVA 2 0 0 25 slave_update ALL 100 1002 1003 IDO4 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 Open Here you can specify the path of the MCU Slave update file By default the specified path corresponds to the software release version Update will start the update process Close closes the window Timeline display shows the update process progression General Display displays the update information All the slaves in a system can be updated at once Choose the Slave unit you want to update by checking the corresponding check box www ateis europe com Page 73 of 260
16. Cancel Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Note be carful when setting priority for both sources conflict may appeared if both sources have the same priority level Attrib here you can specify if this event is a security one or not See How to Use Event to learn more about the security option Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones The output relay part is discussed in the How To Use Output Relay please read it e Pre define Zone here you can specify in which zone music will be routed Note In Route Key mode you don t have to pre define zones as everything is controlled from the front panel However you can specify zone in Route Key mode but keep in mind that the routing will only be activated for default music source e
17. ct ela 204 Musie mee 206 cetacean 211 cii iiio aUas tapa M eiue tape ina 211 Band errr T E rite er MAMMA iD I LI MEA 212 DX GNE E I i MM dM Eu ES d 214 SIL BEN uM Lu LL M ML E Md 216 9 47 18 Iemols Pape etia tdi MART A 216 Log eT 217 Sud FOM IP ENOL DE RPM 217 NM res TUENTUR 217 10 Communication PLOtOCOIS cccccccceeseeeeeeeeeeeeeseeseeeseeeeeseuseeueeeuseeuseeeeuseeeeceseuseeseuseeseuseesses 219 NOME 219 10 2 niega cd coe cha dal hoa need teat d dg rax eda aede cep CC ae E 223 BLUES MOODUS aaa 225 11 Explanation About Monitoring Process eeeeeeeennnnnnnenn eee 238 12 Cancel All and Co xist mode iiic i ca aee a ape Ee rol a oE o Eua uns bra edpE ana veg kwbvar anus 240 13 Log File Messages LIBl eun iere deett ciue t aba 243 14 LCD Faults List and Maintenance
18. p 0 15 Event number based on Index LOG TIME AND LOG FILE 0x172D 0x1730 LOG TIME L Bit 0 5 year 0x172D 0 15 Bit 6 9 month Bit 10 14 day Bit 15 19 hour 16 LOG TIME H Bit 20 25 minutes 0x172E 31 Bit 26 31 second Minutes 0 to 59 www ateis europe com Page 234 of 260 DIVA8 SYSTEM LOG FILE L Bit 0 start end 1 Start 0 end Denier 0715 Bit 1 7 category LOG FILEH Bit 8 19 type DATE AND TIME acm 0x1731 SECONDS 0 15 Seconds 0 to 59 SET SCHEDULER SCHEDULER 0x1737 SECONDS SET Seconds 0 to 59 SCHEDULER 0x1738 MINUTES SET Minutes 0 to 59 SCHEDULER 0x1739 HOURS SET Hours 0 to 23 SCHEDULER 0x173A DAY SET Day 0 to 31 SCHEDULER 0x173B MONTH SET Month 0 to 11 SCHEDULER 0x173C YEAR SET Year 2008 to 2999 SCHEDULER 0x173D DIVA EVENT 0 15 DIVA event number SET 0x173E 0x1 SCEDULER Name 16 eharaciers COMMANDS 0x171F 745 NAME SET Value Input Parameters Description Output Parameters PD P P OOOO 3 Get first event of the log file P 1 2 Get next event of the log file NAK if none PSO PAL Set source level P PZO PZM Set zone monitoring on off PEN PZS Start event if no zones in PZS then start event on pre defined zones www ateis europe com Page 235 of 260 DIVA8 SYSTEM PEN PZS Stop event if no zones in PZS then stop event on pre defined zones Cente scheduler event
19. www ateis europe com Page 236 of 260 DIVA8 SYSTEM EXAMPLES STARTING EVENT IN PREDEFINE ZONES Write the event number at the address 0x172C and send the command Write 0x0001 at address 0x172C Event 1 selected Write 0x0008 at address 0x171F Trigger Event 1 To stop the Event Write 0x0001 at address 0x172C Event 1 selected Write 0x0009 at address 0x171F Stop Event 1 STARTING EVENT IN SELECTED ZONES The zones are coded on 16 Bit and follow the arrangement showed below 1 1 0x001 0008 4A 5 1 16 O 6 OKOOZDN 0 3 J MA O 8 1 0x080 3A 307418 3 J 9 1 O0Ox000 2560 To start the event Write 0x0081 at address 0x1720 zone 1 and 8 selected Write 0x0010 at address 0x172C Event 16 selected Write 0x0008 at address Ox171F Trigger Event 2 To stop the Event Write 0x0081 at address 0x1720 zone 1 and 8 selected Write 0x0010 at address 0x172C Event 16 selected Write 0x0009 at address Ox171F Stop Event 16 www ateis europe com Page 237 of 260 DIVA8 SYSTEM 11 Explanation About Monitoring Process The monitoring can be split into 2 different parts Line monitoring zones and amplifier monitoring Line monitoring is based on impedance measurement and amplifier monitoring on amplifier s gain measurement Amplifier monitoring The amplifier mo
20. Channel 2 Normally Open Channel 3 Channel 4 Channel 5 Normally Open Normally Open Normally Open Channel 6 Channel Channel 8 Normally Open Normally Open Normally Open Machne Master 1 Channel 1 to 8 correspond to the output channel Activations specify if the contact will be closed when active or opened when active Settings by clicking on the edit button you will enter the zone source matrix Link by by clicking the a icon it will open a display in which you will find the CH X already existing trigger Bypass Busy Acknowledge Active at start or active at stop relay e Click on the Edit button of the channel you want to use as a bypass relay the following matrix window will pop up see below www ateis europe com Page 155 of 260 DIVA8 SYSTEM Bypass Relay Setting Master 1 All L arer trer ILI l Normal Message wW OK e With the bottom left drop down menu you will be able to specify for each source type Music 1 Music 2 Normal message Evac message PSS the zone in which the source has to be routed to activate the relay Click OK to validate Note for each of the 8 output relays you can specify multiple zone source routing for the relay activation www ateis europe com Page 156 of 260 DIVA8 SYSTEM 9 34 Do Phase Evacuation Evac Configuration Using the Evac configuration setup allows
21. e Route The Route key act like the one on the front panel it has to be used to validate the routing of a music source in some zones Music Source Selection When creating a music source selection key you will have to specify the corresponding music source with the help of the musis source selection window Key Setting BR Muic Music Level Music Level The Music Level and need to be associated with a music source The selection of the music source is made with the music source selection window Note Music Level and Music Level are two distinct keys a Key Setting E e Event Start Event Stop Those two keys are an additional way of starting and stoping events that are not selected in the message section You can start and stop any kind of event Please be careful to the fact that you will need a stop event key for each start event key for play message type of event When creating an Event Start Stop key you will have to select in the existing event list the one to associate to the key F Key Setting SEE www ateis europe com Page 141 of 260 DIVA8 SYSTEM e Push To Talk Microphone Call The Push To Talk Microphone Call key allows to change the behaviour of the microphone call The default behaviour for the microphone Mic Key is the locked to talk In order to make a microphone call you will have to keep the key pressed during the entire speaking process e Pu
22. gt Fireman Microphone see How to use a Fireman Microphone gt PSS see How to Use PSS Microphone gt Music see How to Use Music Source gt Microphone see How to Use MIC LINE Input gt Line In see How to Use MIC LINE Input Audio Component Audio Component contains high low pass filters PEQ equalizer and compressor limiter components gt Hi Lo Pass see How to Use Filters gt PEQ see How to Use PEQs gt Compressor Limiter see How to Use Compressor Limiter gt Compressor Limiter see How to Use Compressor Limiter 6 6 Design View Area In this area you will www ateis europe com Page 36 of 260 DIVA8 SYSTEM e Develop your DIVA configuration see the How To chapter and DIVA master network see How to perform a DIVA master Network e Access the monitor window see How to Use Monitoring Access to DIVA element and their adjustments ES 2 DIVA System Audio Source Audio Component Note Drag DIVA a Master 1 3 Connection 88 Fault 0 Modified Not compiled Eg fd 6 7 Property Control Section E In this section you can find several control windows docked together into a sliding control panel You can look at the different control windows by bringing the cursor over their tabs at the bottom of the very bottom of the main window The corresponding control window will slide up allowing you to quick examine or quick modify sett
23. Music Source Music 1 iv OK X Cancel Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished www ateis europe com Page 103 of 260 DIVA8 SYSTEM Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay e Music Source here you can choose the music source you want to switch off 9 23 3 10 Mic Line Paging A Mic Line Paging event can be declared in order to be used with any type of trigger www ateis europe com Page 104 of 260 DIVA8 SYSTEM F Mic Line Paging Event Type Mic Line Paging uM Priority Zero equals highest Name Event 9 Attrib Security
24. 86 o USS EVENES AERE 90 www ateis europe com Page 3 of 260 DIVA8 SYSTEM 9 24 Set up Front Panel Wess hig e icciscicisciciinnicscesnnsannnnnsavsunssnvstenaasmedscanasssidneddasuarsninnsasacdannpsetadieschivanessnesint 113 9 25 Use a Fireman Microphone ione bene i d dns tena a Rad 115 3 2B Use Music i coii i EH d usas iae a d Eu 118 2 2051 From Fron Panel oun ideis ipiius i EDU LS IT DID 120 9 26 2 With Modulation Detecflori cs cenas Ear ir daa cosi paccm nuca SR p Rx AR 121 9 26 3 In Permanent Mode ussssseeneenriniiiriiiiriiiiiiikiiiiiiiiriiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiigiiii iilii diii diii 122 9 26 4 From PSS St See Avi end A uS A A ana a OL ae E d anata 122 9 31 NR 145 ERE ER E err mers err rer Perr 146 93 5 EOM IM iu D E 148 Logie a 0 CREER ERIPEEERU TRE 149 q d 1 Logic Ipfi a pati esed xou tdg esed uos one kun eA RR ied pda s p cse h aae ER d 151 dq 52 2 EVGA CAN IMPUS auci pb a tasas aSa NARREA a aa Ea 151 9 32 0 EXternpl Fan bonnan aaan aaa
25. The Mic Line input can be used as a direct input for one external hand microphone and as an additional music input The input gain can be adjusted by the means of the screw on the back panel of DIVA In order to use the Mic Line input first drag and drop Microphone or Line In from the Design Component Section to the Master window Double click the Microphone or Line In icon to enter the Mic Line window see below Mic Line Je peat FBO The Mic Line has three activation modes e Modulation Detection The modulation detection mode is like the VOX mode It allows you to activate a source as soon as a certain amount of signal is detected Logic Input Using music from logic input allows user to manage external trigger to control the routing of music sources Vox Net The MIC LINE input can be use as audio input for Vox net audio streaming please refer to the How to Put DIVA in Vox Net chapter By clicking the Edit Button you will enter the Mic Line Paging Event window Here you will be able to set up parameters of this event see below www ateis europe com Page 143 of 260 DIVA8 SYSTEM F Mic Line Paging Event Type s Mic Line Paging uM Priority Zero equals highest Mame Mic Line Paging Ab 1 Security Next Event None Start Impulse Stop Impulse 2 I3 T4 ES 617 Busy Relay C Enabie 7
26. The lowest priority event will be temporally disabled while the highest priority event is active If the trigger of the lowest priority event is still active after the highest priority event has stopped the lowest priority event must start again in any case It exists two different modes to manage zone conflict Coexist and Cancel All mode Note Events in the chronograms represent also the corresponding trigger Coexist mode allows the lowest priority event to keep going in the non common zones while the highest priority event is active The chronogram on figure 1 describes the process for coexist mode situation Event 1 lowest priority zone 1 2 3 and 4 conflict mode coexist Event 2 highest priority zone 3 and 4 conflict mode whatever Event 1 L Event 2 __ ee Ce Zone 1 L Zone 2 L Zone 3 L Zone 4 Figure 1 Chronogram for Coexist mode with 2 common zone Cancel All mode when the highest priority event overwrites at least one zone of the lowest priority event the lowest priority event will be totally deactivated while the highest priority event is active The chronogram on figure 3 describes the process for cancel All mode situation Event 1 lowest priority zone 1 2 3 and 4 conflict mode Cancel All Event 2 highest priority zone 3 and 4 conflict mode whatever www ateis europe com Page 240 of 260 Event 1 Event 2 Zone 1 Zone 2 Zone 3 Zone 4 DIVA8 SYSTEM
27. www ateis europe com Page 244 of 260 DIVA8 SYSTEM Zone Line B Short MO1 Z 1 B SHORT Master Zone 1 Line B Short MO 1 2 8 B SHORT Master Zone 8 Line B Short 501 2 1 B SHORT Slave 01 Zone 1 Line B Short S01 Z 8 B SHORT Slave 01 Zone 8 Line B Short S15 Z 1 B SHORT Slave 15 Zone 1 Line B Short S15 Z 8 B SHORT Slave 15 Zone 8 Line B Short Fireman Microphone Fault FIREMAN FAIL Fireman Fail FIREMAN OPEN Fireman Open FIREMAN SHORT Fireman Short Evacuation Key Fault EVAC KEY OPEN Evacuation Key Open EVAC KEY SHORT Evacuation Key Short Alarm Key Fault ALARM KEY OPEN Alarm Key Open ALARM KEY SHORT Alarm Key Short Test Key Fault TEST KEY OPEN Test Key Open TEST KEY SHORT Test Key Short All Call Key Fault ALL CALL OPEN All Call Key Open ALL CALL SHORT All Call Key Short PSS DISCONNECT RS485 PSS Disconnect PSS SPK FAULT RS485 PSS Speaker Fault PSS MIC FAULT RS485 PSS Microphone Fault PSS TFT FAULT RS485 PSS TFT Panel Fault EPSS1 DISCONNECT Ethernet PSS 1 Disconnect 551 SPK FAULT Ethernet PSS 1 Speaker Fault EPSS1 MIC FAULT Ethernet PSS 1 Microphone Fault EPSS1 TFT FAULT Ethernet PSS 1 TFT Panel Fault 558 DISCONNECT Ethernet PSS 8 Disconnect EPSS8 SPK FAULT Ethernet PSS 8 Speaker Fault 558 MIC FAULT Ethernet PSS 8 Microphone Fault 558 TFT FAULT Ethernet PSS 8 TFT Panel Fault PSM DISCONNECT PSM Disconnect PSM SPK FAULT PSM Speaker Fault PSM MIC FAULT PSM Microphone Fault NO CONFIGURATION No Configuration Table In M
28. you have the possibility to set an autosave procedure You also can set the number of recent files visible in the file menu recent files www ateis europe com Page 60 of 260 DIVA8 SYSTEM Options olor Scheme v Autosave your design Autosave every 10 minutes 5 Recent files Default Dk Cancel Tick the Autosave your design option in order to activate the autosave option Choose after how much time the autosave will automatically run Choose how many recent files would be visible in the menu file gt recent 9 6 Change Color Scheme In the Color Scheme Options page you will be able to personalize the colour scheme of DIVA software You can change colour for Background Label DSP element Other Windows and Buttons By using the Use Default button you can retrieve default color scheme www ateis europe com Page 61 of 260 DIVA8 SYSTEM Options Background Others CT Windows Color _ 216 228 248 Start Color 216228248 v Button Color Whit End Color 1571855235 v Label Preview Use Gradient Color Start Color _ 216228248 we ene Label End Color 157 185 235 ws Button DSP Element Buton Start Color 202 202 255 v End Color 96 96 255 O Buton Use Default 9 7 Print Project In order to print a project you need to
29. 1 choose the Modbus protocol with the protocol drop down menu Select the appropriate Baud Rate for Modbus choose 9600 Data bit should be set to 8 Stop bit should be set to 1 Parity should be set to No Parity More information about the Modbus protocol and how to use it with DIVA can be found in the communication protocols chapter The serial port pinning information can be found in the How to Wire Devices chapter www ateis europe com Page 190 of 260 DIVA8 SYSTEM 9 43 2 For Notifier Protocol In this chapter we will see how to set the RS232 port of DIVA to communicate with a Notifier fire panel e To access the RS232 port settings click on the RS 232 Port1 or RS 232 Port2 tabs As the settings the same for both ports only one will be introduced Master 1 Note Drag Audio sources 5 232 Portl Voice Amp Baud Rate 38400 Front Panel Setup Data Bits Parity No Parity StopBit Music Amp Ethernet PSSs Protocol None Procedure e RS 232 Port 1 choose the Notifier protocol wit the protocol drop down menu e Select the same Baud Rate choosen on the fire panel In the Notifier protocol the baud rate can be chosen according to the needs Data bit should be set to 8 Stop bit should be set to 1 Parity should be set to No Parity More information about the Notifier protocol and how to use it with DIVA can be found in the communicati
30. 2 Master 1 3 Master 1 DSP Configuration e Cascade Cascades the current opened windows Tile Tiles the screen with the current opened windows Arrange Icons Arranges Icons in a window where possible Here you can find a list of all currently opened windows gt System gt Master 1 www ateis europe com Page 33 of 260 DIVA8 SYSTEM gt Master 1 DSP Configuration 6 2 9 Help Here you will be able to check that the software version corresponds to the one into DIVA units access to software information as well as the help user manual document Version Shows the software version and checks the DIVA units embedded version see how to verify DIVA versions About Opens a information windows about copyrights software release version etc User Manual Opens the complete help user manual 6 3 Toolbars L6 ii i Preset i E TE i RI i x JJ 9 In the DIVA software the different toolbars offers shortcut to main menu items Here are the list of them from left to right and up to down New Project Opens a new project Open Opens existing project Save Saves current project Print Opens the print preview window See How to print project to learn more about the printing options Cut Cuts out the active selection and copies it to the operating system s clipboard Copy Copies the active selection to the operating system s clipboard Paste Pastes the content of the opera
31. 4 Ohms The corresponding speaker line is seen as shorten Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Fireman microphone audio line is defective no audio is received on DIVA Action Check the fireman microphone condition If necessary exchange the fireman microphone Fireman microphone contact line is defective the contact line is seen as an open line no contact Action Check the fireman microphone condition If necessary exchange the fireman microphone Fireman microphone contact line is defective the contact line is seen as an shorten line short circuit on contact Action Check the fireman microphone condition If necessary exchange the fireman microphone Front panel EVAC key contact line is defective the contact line is seen as an open line no contact Action Please contact your Ateis dealer Front panel EVAC key contact line is defective the contact line is seen as an shorten line short circuit on contact Action Please contact your Ateis dealer Front panel ALERT key contact line is defective the contact line is seen as an open line no contact Action Please contact your Ateis dealer Front panel ALERT key contact line is defective the contact line is seen as an shorten line short circuit on contact Action Please c
32. 47 13 Logic Outputs Logic output are simple contact that when closing link the OUTPUT connector to the COM connector The following schematic show a way to create an indicator LED 24V d de Ld RE Ld ee 9 47 14 100V Link Outputs The 100V outputs have been made to link the 100V line from a master DIVA to a slave DIVA To learn more on how to do the connection between master and slave please read this www ateis europe com sx X xs xkEEE x Page 211 of 260 DIVA8 SYSTEM 9 47 15 Computer The computer can be directly connected to a master DIVA by using a CAT5 cable or can be connected to a ethernet network using the same type of cable The next two schematics are example on how to connect masters DIVA to a computer www ateis europe com Page 212 of 260 www ateis europe com DIVA8 SYSTEM ETHERNET NETWORK gt Page 213 of 260 DIVA8 SYSTEM 9 47 16 RS232 There are several ways of using DIVA serial port Here are a few examples Remember to always cross Tx and Rx means that Tx from DIVA goes to Rx from a master With IDAAM XM SW DIVA PORT1 TX Pin 2 TX Pin 9 RX Pin 3 RX Pin 1 GND Pin 6 GND Pin 6 IDA PORT1 TX Pin 2 RX Pin 3 GND Pin 6 IDA PORT2 TX Pin 9 RX Pin 1 GND Pin 6 DIVA PORT1 DIVA PORT2 TX Pin 2 TX Pin 9 RX Pin 3 RX Pin 1 GND Pin 6 GND Pin 6 LAP RS232 Port T
33. 57xx Gigabit Controller Miniport d ordonnancement d w UDP Port 19700 RS232 Port Number 1 Default Dk Cancel After all the network options have been set please refer to the How To Set IP Address paragraph Note changing the UDP port value should be done only with extreme care Wrong settings could make the system unavailable on the network It is highly recommended to use the default UDP port setting 9 3 Search Device To perform a device search go to the menu Tools gt Device Search The Device search window will open see below www ateis europe com Page 55 of 260 DIVA8 SYSTEM Device Search Edit Search Group DIVA Machines Ethemet PSSs Name IP Address Subnet Mask Gateway Address Modify IP No data to d splay Auto Connect Manual Connect O core Buttons explanation Edit Search Group allows to define IP addresses group in which to perform the search process TABs you have access to two different search tabs on to search for master DIVA unit and one to search for Ethernet PSS devices Search starts the search process A progression bar indicates when the search is finished Auto Connect allows the connection to a master DIVA that have been found Select a master in the list by just clicking on the corresponding line Note attention do not select Enable DHCP when clicking on the line it could cause connection problem Manual Connect allows to quickly con
34. Band Preset Select Preset List LED Display 3 System Status 6 8 Status Bar Connection B Fault BEvac 0 Modified Compiled The status bar shows quick look status information about Connection Lights up when real time connected to DIVA Fault Lights up when a faults status is detect onto DIVA e Evac Lights up when a Evac state is detected Login shows in which user level you are logged in Additional Status Information Timeline Shows the progress of commands like opening component control windows e Modified Indicates if the current file has been modified since last save Compiled Indicates if the current file has been compiled or not 7 DIVAPhilosphy DIVA8 G2T system combined with DIVA8S is capable of stand alone operation that complies with security evacuation demands However it offers more than just stand alone features such as complete software control and third party communication through pre defined protocols DIVA8 G2T philosophy needs to be explain in order to clarify the manual structure as well as the software configuration process Software Before anything can be achieved from a DIVA8 G2T system you need to create a software configuration that www ateis europe com Page 38 of 260 DIVA8 SYSTEM reflects the hardware connected to the system and operations like paging message playing The software also allows the management of message memory real time controls
35. CAT5 cable to link the PSS PSM DIVA RJ45 connector to the RJ45 of the PSS Maximum cable length 200m if more distance is needed please use a local 24V power supply Shielded 4 pairs CAT5 www ateis europe com Page 201 of 260 DIVA8 SYSTEM 9 47 4 PSSG2 E Microphone The PSSG2 E can be connected to any TCP IP port in a network The PSSG2 E can be powered through POE Shielded 4 pairs CATS Use local power supply if not connected to a POE port www ateis europe com Page 202 of 260 DIVA8 SYSTEM 9 47 5 PSM8 Microphone In order to achieve a PSM cascade Junction boxes have to be used The following schematic shows how to cascade two PSM microphones In order to increase the number of PSM simply continue the cascading as described Shielded CATS 4 pairs Switch position MASTER hielded 5 4 pairs Switch position SLAVE www ateis europe com Page 203 of 260 DIVA8 SYSTEM 9 47 6 CD16 Microphone The CD16 wall panel microphone console is considered as a PSM for the DIVA system hielded 4 pair CATS 5 pairs to 4 Pairs CAT5 adapter hielded 5 pairs CAT With external power supply due to distance limitation the use of a junction box is required The Junction Box should be placed within 80 meters from the CD16 microphone and the junction box power supply switch should be set to EXT PWR see picture below www ateis europe
36. DIVA8 SYSTEM 10 3 Modbus The MODBUS application protocol is a well known industry standard You can download the protocol specification here http www http www modbus org docs MODBUS Application Protocol V1 1b pdfMODBUS org docs MODBUS Application Protocol V1 1b pdf DIVA master act as a slave in RTU mode binary either on serial port or IP The implementation is based on a register table only It accepts the following public function codes 0x03 Read holding registers 0x04 Read input registers 0x06 Write single register 0x10 Write multiple registers And it may answer with the following exception codes 0x01 Function 0x02 Illegal Data Address 0x03 Illegal Data Value Diva supports slave units number in its configuration file this number is sent inside each command to modbus slaves The frames received are triple checked communication level no answer if unit number is not the one set in DIVA protocol level according to MODBUS specifications exception codes application level according to the table supported command acknowledge All the registers are holding datas formatted as words 16 bits and they form a table which maximum size is 64kwords The table is divided in two parts states and command parameters The states of DIVA faults busy can be get simply by reading the matching registers To trigger an action inside DIVA the parameters must be set first then the command register If action
37. Displayed when accessing set system time menu STOP ALL EVENTS Displayed when accessing stop all events menu READ MAC ADDRESS Displayed when accessing read MAC address menu ICRC DISPLAY Displayed when accessing CRC display menu READ VOLTMETER Displayed when accessing read voltmeter menu Menu level2 J S R READ SUBNET MASK isplayed when accessing read subnet mask submenu R R VAC CONFIRM Menu level 1 IP Menu level 2 D D READ GATEWAY Displayed when accessing read gateway submenu READ PORT Displayed when accessing read port submenu SETIP ADDRESS Displayed when accessing set ip address submenu SET SUBNET MASK Displayed when accessing set subnet mask submenu SET GATEWAY Displayed when accessing set gateway submenu SET PORT Displayed when accessing set port submenu www ateis europe com Page 256 of 260 DIVA8 SYSTEM GET REFERENCE Displayed when accessing get reference submenu FIRMWARE VERSION Displayed when accessing firmware submenu FPGA VERSION pisplayed when accessing FPGA version submenu CONFIGCRC Displayed when accessing config CRC submenu ENGLISH LANGUAGE Displayed when accessing english language submenu Menu funcion ENABLE Displayed when enabling possibility is given SetTime AM PM Password ee a Di i 0123456789ABCDEFGHIJ splayed when entering username and password are required KLMNOPQRSTUVWXYZAPL Displayed when entering username and password are required www a
38. Edit Alarm Event Master 1 Zone 1 Evac Alarm Define the corresponding Evacuation Input activation mode see chapter How to Evacuation Inputs Note only eight of the nine DIVA evacuation input are accessible from the Evac Configuration option The ninth evacuation input is reserved for evacuation reset The next picture shows as an example a finished configuration Evac Configuration Events Device Selection Master 1 Edit Evac Event Edit Alarm Event Device 1 1 Master 1 Zone 1 Alam Zone 2 Alarm Evac Alarm Zone 3 Alarm Evac Zone 4 Alarm Zone 5 Zone 6 Zone 7 Zone 8 www ateis europe com Page 159 of 260 DIVA8 SYSTEM The configuration above will act as follow Evacuation Input 1 CH1 activated the Evac message is played in zone 1 Alert message in zone 2 Evacuation Input 2 CH2 activated if CH1 still active the Evac message is played in zone 1 and 2 Alert message is played in zone 3 Evacuation Input 3 CH3 activated if CH1 and Ch2 still active the Evac message is played in zone 1 2 and 3 Alert message is played in zone 4 Evacuation Input 4 CH4 activated if CH1 CH2 and Ch3 still active the Evac message is played in zone 1 2 3 and 4 Alert message is played in zone 5 www ateis europe com Page 160 of 260 9 35 Use Monitoring DIVA8 SYSTEM In
39. Group IP for the Ethernet PSS using the drop down menu Set the microphone console priority with the arrow keys www ateis europe com Page 136 of 260 DIVA8 SYSTEM Ethernet PSS Management Ethernet PSS1 Ethernet PSS v co s e To configure the Keys click on the dots button under Edit column As the PSSG2 and PSSG2 E uses exactly the same configuration options please refer to the PSSG2 General Page and Keys Page chapter 9 29 Use PSM8 Microphone As described briefly in the External Device PSM chapter The PSM8 is a 10 keys call station on which 8 are programmable with microphone integrated loudspeaker and buzzer It can be used with either IDA4 X M s or DIVA8M It is possible to add up to 11 extensions to the PSM8 increasing programmable keys number to 96 In order to use a PSM microphone with DIVA simply drag and drop the PSM microphone from the Design Component Section to the master window The PSM microphone can also be cascaded and you can slave up to 10 PSMs www ateis europe com Page 137 of 260 DIVA8 SYSTEM Master 1 Note Drag Audio sources here Voice Amp Music 1 Enable Music 2 Enable Mic Line Enable Music Amp Message Enable Fireman Enable To access the PSM programming window simply double click on the PSM icon For more information about PSM microphone and its use please read the PSM user manual that can be f
40. Music 2 one channel Channel 2 None one channel Channel 3 None m Channel 3 None 2 3 5 12 13 14 15 16 17 i8 19 2021 22 Master 1 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 In the mode drop down menu select Multipoint Addr X under the corresponding RS 232 port Choose the Multipoint address according to the multipoint master configuration In the Channel 1 drop down menu select Music 1 Inthe Channel 2 drop down menu select Music 2 In zone codes area create your audio routing corresponding to code received maximum code number 64 Example below shows code 1 zone 1 code zone 2 and code 3 all zone e Compile and Store config At that point DIVA will route Music 1 or Music 2 according to the code received If the master sends Address 4 Channel 2 code 2 DIVA will route Music 2 input to zone 2 Channel 1 or channel 2 will be used depending on remote access master channel selection All other RS 232 data send to other addresses will be ignored by DIVA www ateis europe com Page 198 of 260 DIVA8 SYSTEM 9 45 Page Into Vox net Under Construction 9 46 Configure Remote Access The Remote access DIVA configuration is equal to the Vox net configuration Please refer to the How to Put DIVA in Vox net chapter www ateis europe com Page 199 of 260 DIVA8 SYSTEM 9 47
41. OK will accept the current setting and close the window Cancel will annulled the current settings and close the window 9 26 1 From Front Panel On DIVA front panel you have the possibility to assigned music sources to a zone or multiple set up attenuation for each speaker zone only on music To manage music source the music sources should be set in Route Key www ateis europe com Page 120 of 260 DIVA8 SYSTEM mode see How To Use Music Source The procedure to assign a music source to a zone is the following Select the music source O Press the SELECT button to go from Source 1 to Source 2 O Press SELECT button to go from Source 2 to no selection O Press SELECT button to re select Source 1 e Select the zone s O Press the zone button s you want to activate on Master and or Slaves The corresponding white selection LED s should light s up Validate the routing by pressing the ROUTE button You can independently route music 1 and 2 in group of zones Zone attenuators In each master zone the music level can be attenuated depending your needs The attenuators offer 6 attenuation positions 0 4 8 12 16 20 dB e Adjust the corresponding zone s ATTENUATOR KNOBS to the desired attenuation level Note zones that are monitored cannot be attenuated to 20dB without causing monitoring problems At 20dB attenuation the accuracy of the impedance circuitry reach its limit Note if two
42. PSS Music 1 Enable Music 2 Enable Mic Line Enable Music Amp Message Enable e Hi Lo Pass filters PEQs and Compressor Limiter Audio Component can only be dropped in the MASTER DSP Configuration page on existing connection see below www ateis europe com Page 79 of 260 DIVA8 SYSTEM Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass Bypass Bypass Bypass Me Voice Channel MIC Line Bupass Bypass Tone Fireman MIC Bypass Bypass REN Generator Music Channel PSS Bypass EE Bypass 9 18 Perform a Diva Master Network As briefly explained before you can put several DIVA master on a same network The DIVA master network is based on Ethernet protocol Keep in mind that DIVA slave unit are not on Ethernet network In order to complete a DIVA network you will need the following devices Ethernet Switch Hub Multiple DIVA8M units e computer Before connecting those devices on the network you need to check the IP address of each DIVA master units and set each DIVA IP address corresponding to your project s network By default a new DIVA8M unit has the following IP 192 168 100 100 See How to Set IP Address Link the DIVA master units and the computer to the Ethernet switch see diagram below After the devices have been connected and in order to know if your network is wel
43. Source EGIT 2 5 The Music Source main window allows user to select which mode the music sources are used You can find e Modulation Detection The modulation detection mode is like the VOX mode It allows you to activate a source as soon as a certain amount of signal is detected Permanent Permanent mode allows to set up both music sources routing It will deactivate all the front panel music controls Logic Input Using music from logic input allows user to manage external trigger to control the routing of music sources Vox Net Please refer to the How to Put DIVA in Vox Net chapter e Route Key The route key mode will activate all the music button on the front panel and will offer the possibility to route music from the PSS microphone console For all those different mode you will have to set up the music sources setting by clicking the Edit button for both sources When clicking on the Edit button for music source 1 or 2 you will enter the music source Advanced setting see below Note for music used with logic inputs the music sources settings have to be made with the Music Events www ateis europe com Page 119 of 260 DIVA8 SYSTEM F Advanced Settings SEE Priority 19 ero equals highest Attrib Security Start Impulse Stop Impulse Enable 2 13 4 5 6 7 8 Master Pre define Zone Pre define Zone Enable Master 1 All OU eme OK
44. an external trigger They are separated in three different types esponse EVAC Inputs Responses uml Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Normal Logic Inputs The eight normal logical inputs are simple logical inputs with no monitoring options Evacuation Inputs The nine evacuation inputs can be used as simple logical inputs as well as monitored logical inputs Monitoring type are on contact or voltage UGA In contact monitored mode and using a resistor network the measurement unit can detect 4 different states 1 3 V 2 V 2 7 V and 4 4 V The 4 states correspond respectively to Shortcut Closed Contact Opened contact and Absent open line The voltage UGA monitoring mode is based on polarizing the input with an external 24V source External Fault Inputs External Fault Inputs are used to put DIVA into security mode In order to avoid any sensitivity issue like unwanted triggering of input you can set a response time on either Normal Logic inputs or Evacuation Inputs This response time act like an activation delay it means that the trigger signal should be at least as long as the response time to activate the corresponding logic input Response time range is from Oms to 5000ms The way to configure event for all logic inputs type is identical Please read the few next step to know how
45. application For Anyone who uses this computer all users Only For me Ateis International Installshield Choose an installation folder by default it will be install in C Program Files i ATEIS DIVA v1 0 1 21 InstallShield Wizard Destination Folder Click Next to install to this Folder or click Change to install to a different Folder Install ATEIS DIVA v1 0 1 21 to C Program Files ATEIS DIVA v1 0 1 211 InstallShield Then launch the installation process by clicking Install www ateis europe com Page 25 of 260 DIVA8 SYSTEM i ATEIS DIVA v1 0 1 21 InstallShield Wizard Ready to Install the Program The wizard is ready to begin installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Current Settings Setup Type Typical Destination Folder C Program Files ATEIS DIVA v1 0 1 211 User Information Name Ateis International Company Ateis InstallShield To finish the Installation process just click Finish ie ATEIS DIVA v1 0 1 21 InstallShield Wizard InstallShield Wizard Completed The InstallShield Wizard has successfully installed ATEIS DIVA v1 0 1 21 Click Finish to exit the wizard The installation process will automatically create a Desktop Icon like the one under ATEIS DIVA AEA www ateis europe com Page 26 of 260 DIVA8 SYSTE
46. are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest www ateis europe com Page 102 of 260 DIVA8 SYSTEM Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Music Source here you can choose the music source you want to switch on 9 23 3 9 Music OFF The Music Off event allows to stop music source 1 or 2 with any type of trigger Music sources will stop playing in pre defined zone s chosen in the Music Event window Music Off Event Type Music Off Priority 20 lt ero equals highest Name Event 11 Attrib Security Next Event None Stop Impulse Enable Logic Output Channel Device anti 2 34 5 6 7 Master
47. characters of command string For each command answer can be ACK CR executed DLE CR not executed NACK CR not understood The answers are not inserted inside STX ETX LRC CR frame All commands use logical zones namely codes to reduce the size of datas exchanged For a very simple implementation on a small system code 1 can be output 1 and so on Generally a code is like a group of zones Channel refer to OdB audio signals Slave configuration datas Channel inputs 4 OdB inputs allocated to channels 1 to 4 Channel priorities 4 priority levels allocated to channels 1 to 4 Code zones groups of zones allocated to codes 1 to 99 Announcement Request commandstring Pch code1 code2 code3 For example P12 means call with channel 1 inside zones grouped on code 2 P21 3 means call with channel 2 inside zones grouped on codes 1 and 3 If the command is executed the answer is ACK CR all codes were available or DLE CR at least one code was not available for this channel Announcement Global Clear command string C ch 0 0 For example C100 means clear of announcement running with channel 1 The slave unit must memorize all the time zones requested for announcement for each channel When a clear command is executed the answer can be ACK CR all codes were occupied by the channel or DLE CR at least one code has been taken by another Source Announcement partial clear command string L ch code1 code2 code3 For exa
48. com Page 204 of 260 www ateis europe com DIVA8 SYSTEM hielded 4 pair CAT hielded 5 pairs CAT Page 205 of 260 DIVA8 SYSTEM 9 47 7 Music Sources Connecting music sources to DIVA is easy thanks to the CINCH connections You have a left and right connection for both music sources Keep in mind that DIVA is not a stereo player all music sources are processed in mono www ateis europe com Page 206 of 260 DIVA8 SYSTEM 9 47 8 Mic Line The MIC Line input can be used as a microphone input or as a third music input According to the schematics below use an standard XLR cable to link the microphone to DIVA or connect the Left Right channel of a music source to XLR connector of DIVA Note gain must be adjusted in case of using microphone or a music source i X www ateis europe com Page 207 of 260 DIVA8 SYSTEM 9 47 9 Amplifier The connection to amplifier can slightly change according to the amplifier model used The 0dB output of DIVA are named as follow AIN for positive OdB output AIN for negative OdB output GND for OdB ground output The 100V input are named as follow e AOUT for positive 100V input e AOUT for negative 100V input According to the schematic below the DIVA OdB output are linked to the amplifier OdB input and the DIVA 100V input are linked to the amplifier 100V output Dep
49. compression ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as limiter o Ratio Limiter x 1 here you can specify the limiter ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as compressor Threshold dB here you can specify the threshold level from where the limiter or compressor will start acting Threshold range dB here you can specify the range of level in which the ratio gradually alters from 1 1 to the value set by the ratio parameter soft knee function either by using the slide bar arrow key or by entering directly the value in the dedicated cell Response time 10ms here you specify the attack time for the compressor limiter Recovery time 10ms here you can specify the release time for the compressor Limiter Gain reduction dB indicates the current amount of gain reduction Graphic by clicking on the graphic button this will open the Compressor Limiter graphic edition window see below You can adjust the limitation ratio by moving the red cursor the limiter threshold level and compression ratio by moving the upper blue cursor and the limiter threshold range with the upper yellow cursor You can adjust the compressor threshold level by moving the lower blue cursor and the co
50. entered in the scheduler task window Enable indicates if the task is enable or not ticked means enable Occurrence displays the way the repeat mode has been set for the task e Start displays the date and time at which the task starts e End displays the date and time at which the task stops Note if the task is a Single task start time and end time will be the same Target display which event is affiliated to the task Select All allows to instantaneously select all the tasks from the list Select None allows to instantaneously deselect task selected from the list Del allows to delete selected task from the list Add allows to add a new task to the scheduler Edit allows to edit one task parameters Close close the scheduler window How to set a task To add a scheduler task click on the Add button in the scheduler window Then the Scheduler Task window will pops up www ateis europe com Page 167 of 260 DIVA8 SYSTEM Trigger Event General gt Nave roy Secuny Mee SR gt Eri Occurrence Yearly Monthly Weekly Daily Hourly Minutely End No end 02 08 2010 Number of Times Time 14 36 End by Date Select C New Edi Not Select XM Cancel General Specify a name for the task Default name are Scheduler Task X Tick the Enable option in order to make the task available Trigger Event In the trigger event you will find a lis
51. europe com mid position is 20db below full level value 15 and bottom position is cut Watchdog output counter Event 1 type Load preset 1 Logic output 2 command string 3 Stop event 4 Stop event on zone 5 Play message 6 Paging Fireman and Mic Line 7 Play music 8 music on 9 music off 10 music on by zones 11 music off by zones 12 Toggle music on off 13 Toggle music on off by zones 14 Security mode 16 Stop all event 17 Event 128 type Event 128 name 16 characters Page 232 of 260 DIVA8 SYSTEM WATCHDOG INPUT 0x171E Ci 0 15 Watchdog input counter COMMAND ACKNOWLEDGE 0x171F Command executed Command unknown U N X NK PARAMETERS www ateis europe com Page 233 of 260 DIVA8 SYSTEM ZONES SELECT 0x1720 PZS1 0 15 0x0001 0x8000 Bit field zones 1 to 16 0x1721 PZS2 0 15 0x0001 0x8000 Bit field zones 17 to 32 0x1727 PZS8 0 15 0x0001 0x8000 Bit field zones 113 to 128 0x1728 0 15 0x0001 0x8000 Zone 1 to 128 ZONE MONITOR 15 0x8000 0x8000 to disable monitoring ZONE SOURCE SELECT 0x172A Parameters Wak Pe x id s s ZW Mem gt eme m eme ee 1 eme LEVEL SET 0x172B 0 15 Level not a dB scale EVENT NUMBER 0x172C Description
52. maintenance operation guide LCD DISPLAY NOTE DESCRIPTION AND MAINTENANCE ACTION Internal IC failure M01 FPGA IC FAIL Master FPGA failure Action please contact your Ateis dealer SXX CPLD IC FAIL XX 1 15 Slave CPLD failure Action please contact your Ateis dealer M01 POWER IC FL Master power chip failure Action please contact your Ateis dealer SXX POWER IC FL XX 1 15 Slave power chip failure Action please contact your Ateis dealer www ateis europe com Page 247 of 260 DIVA8 SYSTEM FUNC KEY IC FAIL EVAC KEY IC FAIL ALARM KEY IC FL TEST KEY IC FAIL A C KEY IC FAIL FMM KEY IC FAIL AUDIO LINE IC FL M01 LEAK IC FAIL SXX LEAK IC FAIL XX 1 15 FUNC LED IC FAIL M01 Z LED IC FL SXX Z LED IC FL XX 1 15 Slave connection lost SXX DISCONNECT XX 1 15 Voice amplifier failure M01 V AMP FAIL SXX V AMP FAIL XX 1 15 M01 V GAIN LOW www ateis europe com Front panel keys management chip doesn t answer Action please contact your Ateis dealer Front panel keys management chip doesn t answer Action please contact your Ateis dealer Front panel keys management chip doesn t answer Action please contact your Ateis dealer Front panel keys management chip doesn t answer Action please contact your Ateis dealer Front panel keys management chip doesn t answer Action please contact your Ateis dealer Fireman management chip doesn t answer Action please contact you
53. more about output relay please read the How To Use Output Relay Conflict you can choose between Cancel All or Coexist Pre Chime allows to add a chime message at the beginning of a microphone call Simply choose the pre chime message from the drop down menu Post Chime allows to add a chime message at the end of a microphone call Simply choose the post chime message from the drop down menu e Pre define Zone if ticked you can choose pre defined zone with the zone selector Zone Selection here you can specify the zone s where the call will be played 9 31 1 With Modulation Detection The modulation detection mode allows to automatically route the Mic Line source in case of signal presence The behaviour is the same that for music sources Modulation Detection Threshold 88 r a 28 Attack Time ms d Ju p J Release Time ms Jea Mook In order to use the modulation detection tick the Modulation Detection option for the source you want to use that way Once the option selected you will have access to detection settings e Threshold dB The threshold setting will set the trigger point for activation of the Mic Line source If the threshold is set to 10 dB the Mic Line source activation will take place when the signal received from that source will be over 10 dB e Attack Time ms The Attack time can be understood like the amount of time that the signal has to be over the threshold poin
54. parameter soft knee function either by using the slide bar arrow key or by entering directly the value in the dedicated cell Response time 10ms here you specify the attack time for the compressor limiter Recovery time 10ms here you can specify the release time for the compressor Limiter Gain reduction dB indicates the current amount of gain reduction Graphic by clicking on the graphic button this will open the Compressor Limiter graphic edition window see below You can adjust the compression ratio by moving the red cursor the threshold level by moving the blue cursor and the threshold range with the yellow cursor 0000 www ateis europe com Page 183 of 260 DIVA8 SYSTEM F Comp Limiter Double click on the compressor limiter icon the compressor limiter window pops up see below Adjust the Compressor Limiter parameters to suit your needs Response Gain time reduction Threshold 0m9 dB range Threshold range o Bypass clicking on the bypass button will instantaneously bypass the compressor limiter Soft Knee if the soft knee button is pressed a soft knee will be applied to the compressor limiter instead of a hard knee Compressing this will indicates if the compression is acting or not www ateis europe com Page 184 of 260 DIVA8 SYSTEM o Limiting this will indicates if the limiter is acting or not o Ratio Comp x 1 here you can specify the
55. store configuration is processed 8 1 4 13 Language Select From this menu you can select in which language the front panel information are displayed From the FUNCTION MENU Use the arrow keys to access the LANGUAGE SELECT menu Press OK To change the LCD language into English select ENGLISH LANGUAGE with the arrow keys Press OK You will be asked for validation SURE OK ESC If yes Press OK If no Press ESC To change the LCD language into German select CHINESE LANGUAGE with the arrow keys Press OK You will be asked for validation SURE OK ESC If yes Press OK If no Press ESC To change the LCD language into French select FRENCH LANGUAGE with the arrow keys Press OK You will be asked for validation SURE OK ESC If yes Press OK If no Press ESC Press ESC to go out of the LANGUAGE SELECT menu 8 1 4 14 LEDS LOGIC Test DIVA system provides a LEDs test function that can be activated through the front panel menu www ateis europe com Page 47 of 260 DIVA8 SYSTEM From the FUNCTIONS MENU e Use the arrow keys to access the LEDS LOGIC TEST menu e Press OK e Press ESC to stop the test process e Press ESC to go out of the LEDS LOGIC TEST menu Note if an output contact is configured you can activate LED Testing on DPA amplifiers and BECS battery charger For more information please read DPA series and BECS series manuals 8 2 Managing Music Sources On DIVA fro
56. switch on off by zone Zone Selection here you can specify the zone s where the music will switch On Off by zone 9 23 3 15 Security Mode In order to be compliant to standard and to save energy DIVA has two working mode Normal and Security www ateis europe com Page 110 of 260 DIVA8 SYSTEM Normal DIVA is supplied by the electricity network In normal mode any type of event could be started Security DIVA is supplied by backup batteries after a power supply failure In security mode only security event could be started Music is automatically deactivated The purpose of the security mode is to save energy and to increase DIVA working state under batteries In order to fit the event philosophy you can force DIVA to enter the security mode with the Security Mode event Be careful when using such an event all non security event will be unavailable Security Mode Event Type Security Mode Priority 20 lt ero equals highest Name Event 15 Attrib Not Accessible Next Event None Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib not accessible Next Event here you can select the event to start after the current one is finished Note In order to use a Fault Input contact to trigger the security mode the event must be l
57. system requires only one 2 channel amplifier one for Music one for Voice The Music amplifier will act as a backup amplifier in case of a Voice amplifier failure Each channel can handel up to 500 W of audio power 100 V From the front panels the user can manually route the fireman microphone signal and three digital messages into the selected zones adjust the audio level and switch ON OFF the music in each zone separately In case of evacuation the zones attenuators are automatically bypassed One output contact per zone eight per unit can be activated each time the zone is occupied with a source having a higher priority than the music Alarm or microphone paging As an EN 54 16 security system all DIVA components and peripherals are constantly monitored without music interruption All incidents are recorded into a data file which can be consulted on the DIVA display or on a PC Also any detected faults and alarm status are signalled by general fault and alarm output contacts A local loudspeaker enables selective listening to all the sources and the system s output signals The setup of DIVA is realized through a PC computer and the PCDIVA configuration software Windows compatible Access can be password protected The routing and the level of the music sources can be controlled directly from the PSS microphone All these features make DIVA the ideal system for shopping malls hotels restaurants museums and many other public
58. the corresponding Filter and Compressor Limiter location will be greyed Master 1 DSP Configuration Note Drag Audio components here weet Tone Fireman MIC Bypass Bypass PER Music Channel as i etd On the left of the DSP Configuration window you can find all audio inputs and on the right amplifier outputs 9 37 1 On Inputs To add high or low pass filter on audio input drag and drop Hi Lo Pass filter from the design component section on the Filters location see picture below Note you also can add high and low pass filtering by using the PEQ filter on input read this www ateis europe com Page 171 of 260 DIVA8 SYSTEM Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass Hi Low Pass I Tone Fireman MIC Comp Limiter I Bypass M Ei el Gasa Music Channel BSS Comp Limiter Bypass Hillow Pass e here you can choose the filter type high pass or low pass e Slope here you can specify the slope of the filter 12dB 24dB or 36dB e Frequency here you can specify the filter cutoff frequency by adjusting the slide bar using arrow keys or writing it directly in the cell e Bypass by clicking on the Bypass button you instantaneously bypass the filter e Graphic by clicking o
59. the different live fault occurrences in the system The youngest fault state occurrence is displayed first The fault state is displayed as follow 1st line FAIL INFO REPORT 2nd line FFM KEY OPEN 8 1 3 Events List In the event of any non evacuation audio routing in the DIVA system the Normal Info List will be automatically displayed With the up and down arrow keys you can go through the different evacuation process occurring in the system The youngest evacuation state occurrence is displayed first The normal paging audio routing status is displayed as follow 1st line NORM INFO REPORT 2nd line PLAY MUSIC 1 8 1 4 Functions Menus The function menu allows to set and read system configuration parameters All the following menus and setting are available from front panel User Login User Logout Log Record Set System Time Stop All Events Read Mac Address Read Voltmer IP Settings Audio Levels SPK AMP Monitor Version Display CRC Display Language Select LEDS LOGIC Test 8 1 4 1 User Login The Login menu allows to log into a user account to avoid entering it at each secured menu From the FUNCTIONS MENU www ateis europe com Page 41 of 260 DIVA8 SYSTEM Use arrow keys to access the USER LOGIN menu Press OK It display the current user account Level default is Level 1 Press OK Enter an Username and a Password It displays the current user account level 8 1 4 2 User Lo
60. the general menu 8 1 4 6 Read Mac Address In the world of computer networking there is one common way to set an quasi unique identifier to a network device This is the MAC address Media Access Control Address This number act like a name for one particular network device This cannot be change To see the MAC address just follow this steps From the FUNCTIONS MENU e Use the arrow keys to access the READ MAC ADRESS menu click OK the MAC Address number is displayed Press ESC to go out of the menu 8 1 4 7 Read Voltmeter under construction www ateis europe com Page 43 of 260 DIVA8 SYSTEM 8 1 4 8 IP settings From the front panel menu you can set and read all parameters concerning the network If not already log in DIVA will ask you to enter a valid username and password to be able to modify Ethernet parameters From the FUNCTIONS MENU e Use the arrow keys to access the IP SETTINGS menu Press OK Reading current Ethernet settings e address O Use the arrow keys to access the READ IP ADDRESS submenu Press OK the current IP address is displayed O Press ESC to go back to the IP SETTINGS menu e Subnet mask O Use the arrow keys to access the READ SUBNET MASK submenu o Press OK the current subnet mask is displayed O Press ESC to go back to the IP SETTINGS menu e Gateway O Use the arrow keys to access the READ GATEWAY submenu o Press OK the gateway address is displayed
61. tick respectively the sources to be routed to the DIVA and or the PSS www ateis europe com Page 83 of 260 f Master 1 Note Drag Audio sources here Yoice Amp Music Amp DIVA8 SYSTEM gem M Speaker Parameters System Options Machine 55 5 Slaves Music 1 Enable Front Panel Setup Music 2 Enable Mic Line Enable Menting Message Enable Fireman Enable Ethernet PSSs PSS PSM Enable Music 1 Enable by ticking this option the music source 1 will be routed either on the DIVA monitoring speaker or PSS speaker Music 2 Enable by ticking this option the music source 2 will be routed either on the DIVA monitoring speaker or PSS speaker e Mic Line Enable by ticking this option the Mic Line source will be routed either on the DIVA monitoring speaker or PSS speaker e Message Enable by ticking this option the messages will be played either on the DIVA monitoring speaker or PSS speaker Fireman Enable by ticking this option the messages will be played on PSS speaker For feedback reason the fireman microphone cannot be routed to DIVA monitoring speaker e PSS PSM Enable by ticking this option the PSS PSM paging will be played either on the DIVA monitoring speaker 9 21 Set Power Monitor Diva master and slave unit can be ordered with an optional 230VAC power socket for non EN 54 compliant installation In that case you are able to select the pow
62. will act like an evacuation event So the front panel EVAC LED will light up Chime selection Pre allows the addition of a chime message at the beginning of a microphone call Simply choose the pre chime message from the drop down menu Post allows the addition of a chime message at the end of a microphone call Simply choose the post chime message from the drop down menu Options e Buzzer ON this option allows user to enable the PSM buzzer It will beep for any DIVA fault status and for PSM internal fault Monitoring Pre Amp virtual LED that will light up in case of PSM microphone pre amplifier failure SPK Cable virtual LED that will light up in case of PSM integrated loudspeaker connection failure MIC virtual LED that will light up in case of microphone capsule issue MIC Out virtual LED that check the state of the microphone output Keyboard virtual LED that light up in case of touchpad issue MIC Cable virtual LED that will light up in case of microphone cable issue www ateis europe com Page 139 of 260 DIVA8 SYSTEM Missing virtual LED that light up if the PSM is not plug into DIVA Controls and Indicators Mic gain dB when connected to DIVA you can adjust real time mode the gain of the PSM microphone Speaker gain dB when connected to DIVA you can adjust real time mode the gain of the PSM internal speaker Volume dB indicates the current output level of the music source
63. year If week choose the weekday Seta date and time for the scheduler task Set the end of the task No End task will happen every hour day week month or year from the date and hour selected and will be repeated until the user delete the task Number of times task will happen for a certain number of hour day week month or year from the date and hour selected Example if set every day then 3 number of times the task will happen the first day set and the two next day at the same hour End by date task will happen each hour day week month or year for a certain period can be several hours days weeks etc For this option you will have to specify an end time Make sure the enable option is ticked Press OK O o Your task will be displayed as follow in the scheduler window www ateis europe com Page 169 of 260 DIVA8 SYSTEM Scheduler Master Master 1 m Weekly 2010 08 02 08 00 www ateis europe com No End Event 1 Page 170 of 260 DIVA8 SYSTEM 9 37 Use Filters On DIVA you can add hi pass or low pass filtering on audio input and on amplifier outputs in order to adjust the frequency range to your needs To do so you have to access to the DSP Configuration window e Inthe Master window double click on the DIVA icon The DSP configuration window will pop up Note if no audio sources have been set into the configuration
64. you to easily designed phase evacuation or any evacuation scheme To access the Evac Configuration matrix please go in the menu View gt Evac Configuration The Evac configuration window should pop up Evac Configuration Events Device Selection Edit Evac Event Edit Alarm Event Master 1 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 5 Zone 7 Zone 8 The purpose of the Evac configuration is to use 2 different play message events Evac and Alarm and to use them with Evacuation input in order to create phase evacuation Events When using Evac configuration option you will have to create two dedicated play message events Evac and Alarm Edit Evac Event allows the creation of the evacuation play message event Edit Alarm Event allows the creation of the alarm play message event Once one of this button is pressed the following event edit window is opened www ateis europe com Page 157 of 260 DIVA8 SYSTEM Play Message Event Play Message Priority 0 equals highest Evac Event Attrib v Security Evacuation Start Impulse Stop Impulse Enable 112 3 4 5 6 718 Master Busy Relay Enable DS T4 ES T7 a Master Message Play Made Continuous Conflict Repeat Times 1 OK x Cancel Type display the type of event you are creating Name here you can specify a name for the event created Default is Event X Priority h
65. zone with speaker line connected www ateis europe com Page 164 of 260 DIVA8 SYSTEM 9 35 2 Amplifier Monitoring The amplifier monitoring tabs are separated for music and voice amplifier however controls and displays are identical This is why only the voice amplifier monitoring will be presented F Monitoring Normal Tone Generator Monitoring period Detect Settin Active Mode Bypass Relay Action Type Active Monitor Period Detect Contro Hw bsec Enabled Current Monitor T arget ID 3 Warning After test is done to make sure that the mode is disabled Monitor Device Master 1 y Leakage Impedance Threshold ohm Leakage Impedance Measure ohm Zone Monitoring Voice mp Music Amp Reference unloaded Reference fully loaded Tolerance Measure Get Reference Reset Reference Reset Monitoring Amplifier Monitoring display Reference unloaded displays the reference taken as open line gain Reference fully loaded displays the reference taken as charged line gain Tolerance here you can specify the value of the tolerance wherein measurement has to stay before generating a fault state e Measure displays the measure of the amplifier current gain Amplifier Monitoring Controls Get Reference this button start the get reference process on the amplifier Reset reference this button allows to reset all reference stored Reset Monitoring this button allows to reset the monitoring in case o
66. 0 2x120W SLAVE 2 MASTER SLAVE 1 0000000 0000000 SPA2120 2x120W SLAVE 2 SLAVE 3 00000090 0000000 SPA2120 2x120W SLAVE 4 9 47 18 Remote Panel Under Construction www ateis europe com Page 216 of 260 DIVA8 SYSTEM 9 48 Manage Log File The Log File records all incident and events happening on the DIVA system DIVA has been designed to record up to 2047 occurrences The Log File can be accessed and managed by either the front panel or inside of the software Please read How To Manage Log File From Front Panel or From Software 9 48 1 From Front Panel From the front panel you can read the Log File and clear the Log File To read the Log File From the FUNCTION MENU e Use arrow keys to access the LOG RECORD menu e Press OK Use arrow keys to display different Log Files occurrences Note first occurrence displayed is the latest log file occurrence Log File occurrence are displayed in the following way m First line occurrence number and date XXXX m Second line time and status Start end hh mm ss Status Press OK Log File entry is displayed in plain text on two lines Press Up arrow or Down Arrow keys to go to the previous next log file occurrence Press ESC to go back to the Log File menu For a complete list of Log File entry please read the Log File Messages List chapter To clear the Log file From t
67. 0 Watt or 1 x 1000 W DIVA8M and DIVA8S only need 2 amplifiers One for Paging and one for BGM Back up The background music amplifier is also used as back up amplifier in case of an amplifier failure This unique concept warrantees savings on rack assembly and amplifier power The paging consoles PSS G2 and PSM8 are connected via a secured dedicated link with the central equipment racks When multiple PSM8 s are used into one DIVA8M only the first one master can be used for security purposes The remaining ones slaves are not surveyed A TCP IP link from the main system to the SERVICE area is meant for maintenance use and remote access The paging console can do all calls and zone calls and has a feedback loudspeaker in the unit for system monitoring Central equipment 1x Server PC with Vox Net Server IP media software 1x IP call station PMIP D 1x Intercom doorstation UCIP 1 2x Vox Net In IP media licence www ateis europe com Page 12 of 260 DIVA8 SYSTEM Parking Area 1x DIVA8M master unit 1x DPAfour125 digital power amplifier 1x BECS150 battery backup unit 1x PSS G2 paging console 1x Vox Net OUTPUT Node license Restaurants 1x DIVA8M master unit 1x DPAfour125 digital power amplifier 1x BECS150 battery backup unit 1x PSS G2 paging console 1x Vox Net OUTPUT Node license Wellness area 1x DIVA8M master unit 1x DPAfour250 digital power amplifier 1x BECS
68. 1 Evacuation Input waiting to go inactive after activate command 006 Evacuation Input request to go active denied Status change message Voice Alarm System sends this message in case of Evacuation Input status change fault or out of fault unavailable or returned to available Message VAS gt P y P N3 SP 53 SP 00000 CR Response FP gt A LE With Evacuation Input 3 characters SP ASCII Space 1 character value 0x20 VS3 Status Code 3 characters Status Code Description Evacuation Input fault Evacuation Input out of fault Evacuation Input unavailable Evacuation Input returned to available www ateis europe com Page 221 of 260 DIVA8 SYSTEM Communication fault action Cyclical communication or Status change message e Error on the last received character s echo e Timeout on echo character reception 1 second Voice Alarm System sends a ESC character anc retries 10 Tous gente parvi M du E e CR LF message e Checksum error on response message e Timeout on response message reception 5 seconds Voice Alarm System retries 10 times to send its message After 10 retries Voice Alarm System displays Communication fault with Fire Panel Virtual point command e Error on the last received character s echo e Timeout on echo character reception 1 second Voice Alarm System sends
69. 150 battery backup unit 1x PSS G2 paging console 1x Vox Net OUTPUT Node license Accomodations 1x DIVA8M master controller 1x DIVA8S Slave unit 2x DPAfour250 digital power amplifier 1x BECS150 battery backup unit 3x PSM V2 paging console 1x Vox Net OUTPUT Node license 3 Installation Requirements and Hardware description 3 1 Unpacking DIVA8M G2T Package Content Opening the box you should find the following items o DIVA Master Unit Rack rounting brackets 2 pcs Metal screws Philips M3x6 6 pcs 12 way euroblock connectors 1 pcs 10 way euroblock connectors 3 pcs 5 way euroblock connectors 2 pcs 4 way euroblock connector 11 pcs 230V 24 VDC power supply CD ROM O O O O O O Fireman Microphone www ateis europe com Page 13 of 260 DIVA8 SYSTEM DIVA8S Package Content Opening the box you should find the following items DIVA slave Unit Rack rounting brackets 2 pcs Metal screws Philips M3x6 6 pcs 12 way euroblock connectors 1 pcs 10 way euroblock connectors 3 pcs 4 way euroblock connector 10 pcs 10 way mini euroblock connectors 1 pcs O O O O 2 ways mini euroblock connector 1 pcs o 230 VAC power cable If you realize anything missing please contact your distributor Rack mounting If needed fit the rack mounting brackets to each side of the DIVA by using the 6 pcs Phillips M3x6 screws supplied with the package Sitting The DIVA unit
70. 1T2 I3 T4 F i e L 1 L Busy Relay Enable Logic Output Channel Device E EE EE Conflict Cancel All Coexist Pre Chime _ Pre Chime Enable E Post Chime 5 Post Chime Enable Pre define Zone Pre define Zone Enable isis The Fireman Microphone Paging Event window see above is divided in several section where can set Priority you can specify a priority level between 20 and zero The highest priority level is 0 when 20 is the lowest Security by ticking security you will allow user to make a call when DIVA is in security mode Evacuation ticking this option will make the fireman microphone an evacuation source Note the security and evacuation options are automatically passed to the event accessible in the Advance Setting www ateis europe com Page 117 of 260 DIVA8 SYSTEM The next portion of the window is dedicated to the output relay management In order to find out to use please see How to Use Output Relay Conflict here you can choose how to manage priority conflict Cancel consists of cancelling all the messages or events with a lower priority that are currently playing in the selected zone Coexist permit to momentarily disable the current message or event and to retrieve it as soon as the one with a higher priority has finished Pre Chime the pre chime option allows to play a chi
71. 315 400 500 630 800 1K1 25K1 6K 2K 2 5K3 15K 4K 5K 6 3K 8K 10K12 5K 16K 20K 25K www ateis europe com Page 175 of 260 DIVA8 SYSTEM 9 38 Use PEQs On both output channels and input sources you can add peaking equalization You can add a three band PEQ on inputs and use up to seven bands PEQ on amplifier outputs To access the PEQ on inputs go on the DSP configuration window F Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass I PEQ Voice Channel Tone Fireman MIC Comp Limiter I Bypass I M USER HESS mn Music Channel PSS Comp Limiter I Bypass There is two ways to access the PEQs on amplifier outputs by double clicking the amplifier icon Voice Amp and Music Amp on the Master window see below or directly by the DSP Configuration window www ateis europe com Page 176 of 260 Master 1 Note Drag Audio sour here Voice Amp Music Amp www ateis europe com DIVA8 SYSTEM Speaker Parameters Music 1 Enable Music 2 Enable Mic Line Enable Message Enable Fireman Enable Machine PSS Page 177 of 260 DIVA8 SYSTEM 9 38 1 On Inputs e To add PEQ on an input drag and drop the PEQ from the filter menu in the Design Component Section Note if there is already hi lo pass filtering on the same input you won
72. 79 112 0x0001 0x8000 it field logic outputs 113 128 0 Normal 1 Trigger ZONES SOURCE STATE 1 128 0x0A16 0x0A95 Lm Raw Bm O EN L eame For cant sore BR sei Ww e miss _ 0x8000 each source Bit15 is set if the zone is in evacuation ZONES FAULT STATE 1 128 0x0A96 0x0B15 Wer Wee we Short Circuit B side Open Circuit A side 5 0x0010 ZAIM Impedance A side 0x0020 ZBIM Impedance B side 0X8000 Monitoring is off SCHEDULER ums Dei 0 15 Number of existing scheduler events 0x0B17 Scheduler 1 Seconds 0 to 59 www ateis europe com Page 230 of 260 0x0B1D 0 15 DIVA8 SYSTEM Ox0B1C 10 15 X Schedulr t Year 2008 to 2999 DIVA event number 1 0x0B1E 0x0B25 0905 Scheduler 1 Name 0x128F 0x1296 Scheduler 128 Name www ateis europe com Page 231 of 260 AMPLIFIERS FAULTS 0x1297 0x0001 1 2 0x0002 Ware DIVA8 SYSTEM Music amplifier fault Voice amplifier fault Music amplifier used as backup SOURCES AUDIO LEVELS 0x1298 0x129C 0x1298 0 15 Address Bit 0x1299 0x129A 0x129B Mask Top position is full level value 31 level 80dB or less value 0 WATCHDOG OUTPUT Address EI A X Ox129D 0 15 EVENT TYPE AND NAME 0 15 0x129E COMMANDS COMMANDS TABLE www ateis
73. A To start the reverse process go to the menu Operations gt Reverse or use the Reverse Shortcut on the compile toolbar e Click Reverse you can follow the advancement of the process on the timeline display The reverse window will be open see below www ateis europe com Page 76 of 260 DIVA8 SYSTEM Reverse Reverse Close 9 17 Add Design Component After starting a new project the System window is opened On the left you will find the Design Component Section The DIVA software have been made to simply add remove component All the components are drag amp drop items Each component can only be dropped in its own place www ateis europe com Page 77 of 260 DIVA8 SYSTEM System DIVA System Master Audio Source S Fireman Microphone ep PSS 9 Music Microphone w Line In 2 Audio Component Filter HijLo Pass PEQ Compressor Limiter amp Compressor Limiter Compressor Limiter The DIVA Slave unit can only be dropped in the System main window see below Note Drag DIVA devices here Master 1 1192 168 1 201 www ateis europe com Page 78 of 260 DIVA8 SYSTEM e Audio sources Audio Sources folder can only be dropped in the Master window and only in the right location see below Master 1 Note Drag Audio sources her Speaker Parameters Voice Amp Machine
74. Adjust the music 2 input level using arrow keys and or keys O Press ESC to go back to the AUDIO LEVELS menu Monitoring speaker O Use arrow keys to access SET SPEAKER LV submenu o Press OK o Adjust the monitoring speaker output level using arrow keys and or keys Press ESC to go back to the AUDIO LEVELS menu 8 1 4 10 SPK AMP Monitor The reset monitor menu allows user to reset the speaker line and amplifier monitoring after fixing an eventual line or amplifier problems From the FUNCTIONS MENU Use arrow keys to access SPK AMP MONITOR menu Use the arrow keys to access the RESET MONITOR submenu Press OK You will be asked for validation SURE OK ESC If yes press OK If no press ESC You can get monitoring references by accessing the Get Reference submenu You can get references individually for each speaker zones and amplifiers Use the arrow keys to access the GET REFERENCE submenu Press OK e Using arrow keys and keys choose the zone or amplifier on which you want to take the references Zones and amplifiers are displayed as follow o M01 ZONE X master s zones M01 VOICE AMP master voice amplifier M01 MUSIC AMP master music amplifier SOX ZONE X slaves zones SOX VOIC AMP slaves voice amplifiers SOX MUSIC AMP slaves music amplifiers e Press OK The new monitoring reference is now taken and stored 8 1 4 11 Versions Display The VERSIONS DISPLAY menu allows users to ve
75. CS2 Checksum 2 characters Virtual point command Fire Panel sends the following message if it wants to activate or deactivate an evacuation input on Voice Alarm System e Command FP gt P y C PN2 VN3 SP VC3 CS2 CR LF e Response VAS gt V P N3 SP VS3 SP 00000 CR With PN2 Panel Number 2 characters value 0 VN3 Evacuation Input 3 characters SP ASCII Space 1 character value 0x20 VC3 Command Code 3 characters CS2 Checksum 2 characters VS3 Status Code 3 characters www ateis europe com Page 220 of 260 DIVA8 SYSTEM If the Command Code is 001 or 002 the Voice Alarm System will give no response because of the fact that these messages are only informative messages Messages with Command Code 005 will not be interpreted Only the Mode 1 should be used to activate an Evacuation Input If the Command Code is 006 and the Evacuation Input is 000 the number of Voice Alarm System responses depends on the number of faulty Evacuation Inputs Command Code Description 000 No action enquire status onl Evacuation Input has been enabled informative onl Evacuation Input has been disabled informative onl 006 jRetransmitfault or unavailable message s for the Evacuation Input s Status Code Description 000 Evacuation Input not defined within Voice Alarm System Evacuation Input active mode
76. Clip Threshold dB allows the setting of the threshold point for the Clip indicator Mic Overflow this is a LED indicator that light up when a too high level is detected on the PSM microphone Speaker Overflow this is a LED indicator that light up when a too high level is detected on the PSM speaker Clip indicates when the signal is clipping 9 29 2 Keys Page The key tab offers the possibility to program the eight first keys of the PSM Host and the keys of several PSM extension keypad keypad 1 to 11 In order to go through the different extension use the main drop down menu j v a on DO amp wm In order to create a key follow the next few steps e With the drop down menu corresponding to the key you want to set select a key type some keys type will automatically open a popup window for parameters setting see below for the complete list ok key functions Edit your key settings by clicking on the Edit button Here is a list of the key functions that can be used with the PSM Zone Selection The zone selection key allows user to arrange to his will the selection of the zone As soon as the zone selection type has been selected the zone selection window will appear Simply the zone corresponding to your needs and click OK www ateis europe com Page 140 of 260 DIVA8 SYSTEM Zone Selection Master 1 4 2 4 5 6 7 8 All
77. Line B Zb Line A B 1 1 Za 1 Zb To ensure a high precision measure for each reference A B and B A three values are taken Example Line A VO3 channel Line A Voice amp channel and Line A Music amp channel In the references display the value will change according to channel routed on each zone Example Zone 1 Line A ref VO3 530 Ohm Voice 545 Ohm Music 540 Ohm www ateis europe com Page 238 of 260 DIVA8 SYSTEM When music is routed to zone 1 the display shows 540 Ohm As soon as a Voice call is routed on the zone 1 the display will show 545 Ohm If no music or no voice call is routed on zone 1 the display will show 530 Ohm The schematics above explain how the different channel are routed to zone S and how the impedance measurement is made Signal VSix VSgx ISix and ISgx are computed into DSP and then compared to reference values The real measure is made with A and B in parallel In the case the measured value differs from the reference value Line A will be measured independently and compare to the Line A reference and the same process is done for Line B TRANSFORMER VOLTAGE TRANSFORMER www ateis europe com Page 239 of 260 DIVA8 SYSTEM 12 Cancel All and Coexist mode The priority parameter of an event allows it to be started or not if there is already one event active A higher priority event will overwrite zones of a lower priority event in any case
78. M 5 2 Uninstall To uninstall a current version of the DIVA software please follow the next few steps Click on start gt Program gt ATEIS gt DIVA gt ATEIS DIVA v1 0 0 Uninstall Windows Installer will ask you if you are really sure to remove this program click Yes 5 3 Software Upgrade In case of a new release of the DIVA software Please go to the ATEIS website in order to download the last software version Before installing the new software please uninstall the current version Double click the new software version icon Follow the installation process 6 DIVA Software Presentation The chapter will introduce to you the DIVA software This is a visual presentation in order to let you know where you can find the needed tools After installing the DIVA software you can access it e Either by double clicking on the Desktop icon o ATEIS DIVA v1 0 0 beta 10 Or by start gt program files gt Ateis gt ATEIS DIVA v1 x x The DIVA software starts with no file loaded and a blank worksheet looking as follow 1 2 i File Edit User Operation Tools Lock Window Help A 5 6B lth laces 2 Audio Component i pre d o En 9e System nx DIVA System Audio Source Connection Fault 8 aa www ateis europe com Page 27 of 260
79. Name displays the account name Level displays the corresponding user account level Authority Level displays in the user account authorization level Hint by clicking on the Hint button on user account it will display in plain text the right and restriction for the account The list below explains how the button works Add allows to add new user account Edit allows to edit existing account parameters Select All can instantaneously select all the existing account Select none instantaneously unselect the previously selected account Delete allows to delete accounts Close closes the User Management window Note by default four user accounts are created corresponding to the four user level existing in DIVA application www ateis europe com Page 66 of 260 DIVA8 SYSTEM 9 10 1 Add User Account To add a new user account simply click on the add button A New Account pop up window like the one below will appear New Account Please enter user account name Press Next to continue Cancel Enter the user name for the new account Click next New Account Please enter account password O Please enter again Press Next to continue Press Back to go back to previous step Enter a password for the account created Confirm password Click Next to continue the process of creating an account Click Back to go back to the previous step New Account Please select the level o
80. O Press ESC to go back to the IP SETTINGS menu UDP Port Use the arrow keys to access the READ PORT submenu o Press OK the UDP port is displayed O Press ESC to go back to the IP SETTINGS menu Changing Ethernet settings e address o Use the arrow keys to access the SET IP ADDRESS submenu Press OK Enter the IP address value using arrow keys and keys Default address is 192 168 100 100 Press OK You will be asked for validation REBOOT VALIDATE Note after each change in the Ethernet settings the DIVA system need to reboot If yes press OK If no press ESC O O e Subnet mask o Use the arrow keys to access the SET SUBNET MASK submenu Press OK Enter the subnet mask value using arrow keys and keys Default mask is 255 255 255 000 Press OK You will be asked for validation REBOOT VALIDATE Note after each change in the Ethernet settings the DIVA system need to reboot If yes press OK Ifno press ESC Gateway address O Use the arrow keys to access the SET GATEWAY submenu www ateis europe com Page 44 of 260 DIVA8 SYSTEM Press OK Enter the gateway address value using arrow keys and keys Default address is 192 168 100 001 Press OK You will be asked for validation REBOOT VALIDATE Note after each change in the Ethernet settings the DIVA system need to reboot If yes press OK If no press ESC O00 0 O O UD
81. P port Use the arrow keys to access the SET PORT submenu Press OK Enter the UDP port value using arrow keys and keys Default UDP port value is 19700 Press OK You will be asked for validation REBOOT VALIDATE Note after each change in the Ethernet settings the DIVA system need to reboot If yes press OK Ifno press ESC 0000 0 8 1 4 9 Audio Levels The AUDIO LEVELS menu offers the possibility to adjust the audio level of the following sources and output Fireman microphone Mic Line input Music 1 Music 2 Monitoring speaker To set the level of a source or output follow the next steps From the FUNCTIONS MENU e Use arrow keys to access AUDIO LEVELS menu e Press OK Fireman microphone O Use arrow keys to access SET FIREMAN LV submenu o Press OK o Adjust the firman microphone level using arrow keys and or keys O Press ESC to go back to the AUDIO LEVELS menu e Mic Line input O Use arrow keys to access SET MIC LINE LV submenu o Press OK o Adjust the Mic line input level using arrow keys and or keys O Press ESC to go back to the AUDIO LEVELS menu Music 1 O Use arrow keys to access SET MUSIC 1 LV submenu o Press OK o Adjust the music 1 input level using arrow keys and or keys O Press ESC to go back to the AUDIO LEVELS menu e Music 2 O Use arrow keys to access SET MUSIC 2 LV submenu www ateis europe com Page 45 of 260 DIVA8 SYSTEM Press OK o
82. Q by moving the yellow cursor Bandwidth is controlled by the orange cursor 30 10 125 16 20 25 31 5 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K1 25K1 6K 2K 2 5K3 15K 4K 5K 6 3K 8K 10K12 5K 16K 20K 25K www ateis europe com Page 179 of 260 DIVA8 SYSTEM 9 38 2 On Outputs AMP PEQ N A e Adjust the PEQ parameters to suit your needs Bandwidth Oct here you can adjust the factor of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell Frequency Hz here sou can adjust the central frequency of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell Gain dB here you can adjust the PEQ gain either by using the slide bar arrow key or by entering directly the value in the dedicated cell PEQ Overflow Signal indicates if there is an overflow after the addition of the PEQ to the base signal Bypass by clicking on the Bypass All button you will instantaneously bypass all three PEQ filter Volume dB displays the real time volume on output Level dB allows to adjust the output level either by using the slide bar arrow key or by entering directly the value in the dedicated cell Level Overflow indicates if there is signal overflow on the base signal Graphic by clicking on the Graphic button you will enter the PEQ graphic edition window see below You will be able to adjus
83. RE OK ESC Press OK The message is played in the pre defined zone s 0000000 From MSG TEST button O Press the MSG TEST button DIVA displays TEST KEY PROCESS Press OK DIVA displays TEST CONFIRM 1 SURE OK ESC Press OK DIVA displays TEST CONFIRM SURE OK ESC Press OK The message is played in the pre defined zone s 000000 0 Starting message with a manual zone s selection e Press the zone button s where you want the message to be played The corresponding white selection LED s should light s up From EVAC button Liftthe button cover Press the EVAC button DIVA displays KEY PROCESS Press OK DIVA displays ENABLE 1 SURE Press OK DIVA displays ENABLE 2 SURE OK ESC Press OK The message is played in the manually selected zone s 0000000 0 e Press the zone button s where you want the message to be played The corresponding white selection LED s should light s up From ALERT button O Press the ALERT button www ateis europe com Page 49 of 260 DIVA8 SYSTEM DIVA displays ALERT KEY PROCESS Press OK DIVA displays ALERT ENABLE 1 SURE OK ESC Press OK DIVA displays ALERT ENABLE 2 SURE OK ESC Press OK The message is played in the pre defined zone s 000000 0 e Press the zone button s where you want the message to be played The corresponding white selection LED s should light s up From MSG
84. S s audio systems have been installed in the following markets Railways Subways Airports High raise buildings Hotels Restaurants www ateis europe com Page 7 of 260 Shopping malls Theme parks Places of worship Stadia Museums Industrial buildings Industrial plants Commercial buildings www ateis europe com DIVA8 SYSTEM Page 8 of 260 DIVA8 SYSTEM 1 2 EC Declaration of Conformity Documentation CE marking This needs to be added to each commercial technical document EC DECLARATION OF CONFORMITY Ateis as manufacturer having sole responsibility hereby declares that our delivered version of the following product complies with the applicable directives In case of alterations of the product not agreed upon by Ateis this declaration is no longer valid EN54 16 2008 Voice Alarm Control and Indicating Equipment VACIE Product DIVA8 System VACIE Certified options Audible warning Manual reset of the voice alarm condition Voice alarm condition output Indication of faults related to the transmission path of the CIE Indication of faults related to voice alarm zones Voice alarm manual control Interface to external control device s Emergency microphones Redundant amplifiers Ancillary functions Commercial paging Backgroud music distribution www ateis europe com Page 9 of 260 DIVA8 SYSTEM 2 DIVAS8 System Pre
85. System and IDA8 System and communicates over a dedicated RS485 for Power audio and DATA The unit comprises of 16 zones 16 buttons with fist firemen s microphone in a metal surface mount wall box It provides robust IP 30 protection Each CD16 contains a PSM Master PCB with extension keypad and uses the same architecture as for the PSM series of microphone consoles DIVA8 System can handle 1 CD16 when each IDA4 System and IDA8 System can handle up to 32 CD16 units www ateis europe com Page 22 of 260 DIVA8 SYSTEM The buttons can represent a single zone or a group of zones All buttons can be programmed with drag amp drop features from the DIVA8 System IDA4 System and IDA8 System GUI and the PTT button can be programmed for Push To Talk or for latching functionality The unit offers Hold and Busy LED signals in addition to the zone LED s and these allow the easy identification of selection Busy signals for the user In addition to comply with EN 54 16 separate POWER FAULT and EVAC indicators are provided Additional RCA connectors with selection buttons support local audio injection for commercial usage The RS485 communication protocol offers daisy chaining of up to 300 m on a simple CAT5 cable and yet makes outlets easy to connect via a standard RJ45 connector For more information about how to use the CD16 microphone console please read the CD16 user manual and the How to use CD16 microphones cha
86. TEST button o Press the MSG TEST button DIVA displays TEST KEY PROCESS Press OK DIVA displays TEST ENABLE 1 SURE OK ESC Press OK DIVA displays TEST ENABLE 2 SURE OK ESC Press OK The message is played in the pre defined zone s 0000000 Stopping message broadcasting e Reset the evacuation process o Press the RESET button DIVA displays RESET KEY PROCESS Press OK DIVA displays RESET ENABLE 1 SURE OK ESC Press OK DIVA displays RESET ENABLE 2 SURE OK ESC Press OK A software reset is applied Any active trigger fault contact etc are restarted after the software reset 000000 0 e Stop ALERT or MSG TEST broadcasting Press the ALERT or MSG TEST button DIVA displays ALERT or MSG TEST KEY PROCESS Press OK DIVA displays ALERT or MSG TEST DISABLE 1 SURE OK ESC Press OK DIVA displays ALERT or MSG TEST DISABLE 2 SURE OK ESC Press OK The message broadcasting is stopped 0000000 0 8 3 1 2 Fireman Microphone Depending on the software configuration created there is two distinct way of starting a Fireman microphone call with a manual zone selection or with pre define zone s selection To learn more on how to configure pre define zone selection fro the fireman microphone please read the how to use a fireman microphone chapter Starting a call with pre define zone s Press the fireman microphone contact to start speaking in the pre defined zone s the corresponding zone E
87. VA acts as a slave unit in bot Vox Net and Modan From a DIVA point of view the Vox net protocol and Modan protocol are equivalent Vox Net Modan explanation The basics of those protocols communication is that DIVA receive audio stream along with RS 232 command So from a DIVA machine point of view one will have to set RS 232 port setting to receive command and set audio input to be triggered by RS 232 command In a simple manner RS 232 will allow to activate a music source routing in zone s according to the parameter sent via RS 232 Both protocol are acting from a DIVA point of view as Master Slave network in which DIVA is always a slave More information about Modan command could be found about Vox Net Modan protocol in the Communication Protocols chapter Data transmission mode The Modan protocols offers two different ways of communication between devices Point to Point and Multipoint Point to Point is a direct communication path between to system where Multipoint is using RS 232 bus with device dependant addresses Vox net always use the Multipoint mode and remote access offers the choice between the two mode e Incase of using Point to Point mode no addresses are affiliated to devices in the remote access system Incase of Multipoint all slave devices have a static address range from 1 to 32 Audio Routing As stated before the Master Vox net server client or remote access master send information to the slave
88. VA8 SYSTEM F Fireman Mic Paging Event J Type Name Fireman Mic Paging Event 8 Priority 4 equals highest Attrib Security Next Event None Start Impulse i Stop Impulse IT Enable enath Busy Relay Enable Conflict Pre Chime Post Chime Pre define Zone Pre Chime Enable Post Chime Enable Logic Output Channel Ee ER ER Device 1 5 Cancel All Coexist Pre define Zone Enable Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest O is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished www ateis europe com Page 101 of 260 DIVA8 SYSTEM Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing cont
89. VAC LED s are lit Starting a call with manual zone s selection www ateis europe com Page 50 of 260 DIVA8 SYSTEM Press the zone button s where you want the call to be played The corresponding white selection LED s are lit Press the fireman microphone contact to start speaking in the selected zone s the corresponding zone EVAC LED s are lit Stopping a fireman microphone call Release the fireman microphone contact if used in push to talk mode Press the fireman microphone contact a second time if used in Lock to talk mode Note if the fireman microphone is using a pre and or post chime message the RUNNING LED will blink during the chime broadcasting www ateis europe com Page 51 of 260 DIVA8 SYSTEM 9 How To The How To section is divided by theme Each Theme discusses about how to perform an action or multiple action in order to build a configuration The Philosophy of this chapter is that if you read it from A to Z you will be able to perform a full advanced DIVA configuration But it has been written to offer quick navigation so that you can find specific information about one theme Here under you will find a complete list of the How To topics Set Computer Network parameters Configure network Options Search Device Set IP Address Save Open Change Colour Scheme Print Project Start a New Project Set up System Options Use the User Management Enter Pass
90. Wire Devices In this chapter you will find schematics about how to wire DIVA with external devices Here is the list of devices that will be discussed Power Supply Fireman Microphone PSSG2 Microphone PSSG2 E Microphone PSM Microphone CD16 Microphone Music Sources Mic Line Amplifier Speaker lines Normal Logic Inputs Evacuation Inputs Logic Outputs 100V link Output Computer RS232 DIVA8S Remote Panel 9 47 1 Power Supply The DIVA operating voltage supply is 24VDC Pleas use only the provided power block or something equivalent To connect DIVA to a 24VDC power supply use an euroblock connector in order to link the power supply to the 24VDC and OV DIVA inputs DIVA8 Master To BECS EN 54 4 system power outputs In order to fullfil european standard DIVA8 system should be connected to a battery charger and a security power supply like Ateis BECS series www ateis europe com Page 200 of 260 DIVA8 SYSTEM 9 47 2 Fireman Microphone To connect the SHM1 fireman microphone simply connect the SHM1 connector with the front panel fireman microphone connector In case of using an other microphone use the back connector to connect the microphone see the lower picture Note the front panel connector and the back connector are parallel connected Please only use one of them 9 47 3 PSSG2 Microphone In order to connect the PSS or PSSg2 microphone to DIVA simply use a shielded 4 pairs
91. X Pin 3 RX Pin 2 GND Pin 6 LAP RS232 Port TX Pin 3 RX Pin 2 GND Pin 6 zz Js Je O With VNB for Vox Net application or as RS 232 carrier www ateis europe com Page 214 of 260 DIVA8 SYSTEM DIVA PORT1 DIVA PORT2 TX Pin 2 TX Pin 9 RX Pin 3 RX Pin 1 GND Pin 6 GND Pin 6 VNB RS232 Port VNB 5232 Port RX TX GND www ateis europe com Page 215 of 260 DIVA8 SYSTEM 9 47 17 DIVA8S To connect one slave DIVA to a master simply connect the Link Out connector of the Master to the Link In of the slave with a RJ 45 CAT5 cable and so on for the next slave unit To pass the audio to the slave unit simply connect the Master 100V Link connector to the slave 100V In connectors If more than 500W of power is needed you can add two amplifier channela per slave unit To synchronize the audio simply link the OdB output of the master to the additional amplifiers OdB input and additional amplifier 100V output to the corresponding 100V slave input The first schematic shows how to perform a DIVA system with 1 master and 2 slave units using the same amplifier The second schematic shows how to perform a DIVA system with two additional amplifiers On both schematics the OdB lines are displayed in black and 100V lines in red Note connections are not fully described example OcB line is described as one wire instead of 3 a MASTER SLAVE 1 6000000 SPA212
92. a ESC character e Checksum error on command message Voice Alarm System sends the NAK message gt N CR www ateis europe com Page 222 of 260 DIVA8 SYSTEM 10 2 Voc net Modan This document describes Vox net MODAN protocol used for remote control applications Written by R Seassau The Modan protocol is intended to provide communication between two public address and or voice alarm systems One system is declared as master and the other as slave and with this protocol the master can send announcement request to the slave and also get status faults informations from the slave At the beginning this protocol has been developed for point to point link but a multipoint extension has been added 1 master and more than 1 slave All the units must handle both modes The physical layer is composed of 1 to 4 audio channels mostly OdB from the master to the slave and a regular RS232 422 485 serial link between master and slave In case of multipoint configuration serial link can be RS485 with proper 232 485 interfaces if needed or any suitable data network Serial link default values are 9600 bauds even parity 8 bits 1 stop Definitions STX 2 ETX 3 CR 13 ACK 6 DLE 16 NACK 21 SP 32 ENQ 5 with all values in decimal Upper case symbols are fixed POINT TO POINT PROTOCOL DEFINITIONS Commands format STX command string ETX CS CR where CS is the checksum exclusive or of all
93. aR iA Ae e 152 Use REAY cca AARAA 153 LATTE e E eaa RE 153 Me AN eaa a eee eral 154 pS SC MP UT E A AE PER ee 154 RESI CREE EUER ERREUR 154 CERES TO ERE NEEDED 155 9 34 Do Phase Evacuation Evac Configuration e 157 www ateis europe com Page 4 of 260 DIVA8 SYSTEM 942 Use Tone Genera Of cana Seca pba 188 v43 Use RS232 DRAN 190 A EEG ROODE oa cee 190 quisc For Noter tai aah ica te dai del gs ea 191 5 46 Configure Remote ACEBSS oisi 199 Wire I fI E E EE EE 200 Se eund tts N uox en iubebo o o Sd dh tl b ota AER dl 200 irs SICCO UM ccc an o bet Dr pe cda acu id belt iO C GU ERR 201 marg a tacite Rope dana oon whe ORC uada ae tcd anc p pO QU ic 201 ETE Mu t CR CECINIT 202 E TEETE ec iale o i OCA ics E Gu Xni CR GU aS a i al 203 CIT ON CDT ts
94. access the print preview page To access this page go in the menu File gt Print or click on the print shortcut highlighted on picture below in the edit toolbar AAAS h Once you launch the print command you will enter the Print Preview window see below The print preview offer you the possibility to print DIVA main windows separately In case of DIVA master Network you can select which master window you want to print Print Preview ij 2 Master Master 1 Items System Configuration Note Drag DIVA vices here Master 1 The print toolbar include www ateis europe com Page 62 of 260 DIVA8 SYSTEM Print Button in order to send the print request Print Setting Button in order to set your printer parameters Master Drop Down Menu here you can change the DIVA master unit Items Drop Down Menu Here you can select which window have to be print choose between System configuration Master Configuration and DSP Configuration 9 8 Start a New Project In order to start a new project go to the menu File gt New or click on the New shortcut on the edit toolbar see below or even type ctrl n b X acy ot After launching a new project the DIVA software start a new system window looking like the one on the picture below DIVA Untitled diva System 2 DIVA System Audio Source Audio Component Note Drag DIVA devices
95. achine CFG CRC ERROR Configuration CRC Error CFG VERSION ERR Configuration Version Error MO 1 El 1 OPEN MO 1 Evacuation Input 1 Open MO 1 EI 9 OPEN MO 1 Evacuation Input 9 Open 501 EI 1 OPEN Slave O1 Evacuation Input 1 Open S01 EI 9 OPEN Slave 01 Evacuation Input 9 Open 15 El 1 OPEN Slave 15 Evacuation Input 1 Open 515 E 9 OPEN Slave 15 Evacuation Input 9 Open www ateis europe com Page 245 of 260 DIVA8 SYSTEM Evacuation Input Short MO1 El 1 SHORT Master Evacuation Input 1 Short MO 1 El 9 SHORT Master Evacuation Input 9 Short 501 EI 1 SHORT Slave 01 Evacuation Input 1 Short S01 EI 9 SHORT Slave 01 Evacuation Input 9 Short 15 EI 1 SHORT Slave 15 Evacuation Input 1 Short 15 EI 9 SHORT Slave 15 Evacuation Input 9 Short Exterior Fault Input Action MO1 EFI 1 ACTION Master Exterior Fault Input 1 Action MO1 EFI 2 ACTION Master Exterior Fault Input 2 Action S01 EFI 1 ACTION Slave 01 Exterior Fault Input 1 Action S01 EFI 2 ACTION Slave 01 Exterior Fault Input 2 Action 15 EFI 1 ACTION Slave 15 Exterior Fault Input 1 Action 15 EFI 2 ACTION Slave 15 Exterior Fault Input 2 Action MSG FLASH FAULT Storage Message Flash Block Fault CFG FLASH FAULT Storage Cofiguration Table Flash Block Fault PGM FLASH FAULT Storage Program Flash Block Fault www ateis europe com Page 246 of 260 14 DIVA8 SYSTEM LCD Faults List and Maintenance Guide Main parts of the DIVA8 system are constantly monitored so the fault list an
96. act pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones To learn more about output relay please read the How To Use Output Relay Conflict you can choose between Cancel All or Coexist Pre Chime Before a call you can add a chime message Here if Pre Chime Enable is selected you can select which message will be used as pre chime Post Chime After a call you can add a chime message Here if Post Chime Enable is selected you can select which message will be used as post chime Pre define Zone if ticked you can choose pre defined zone with the zone selector Zone Selection here you can specify the zone s where the call will be played 9 23 3 8 Music ON The Music On event allows to start music source 1 or 2 with any type of trigger Music sources will start playing in pre defined zone s chosen in the Music Event window Music On Event Type Music On Priority 20 lt ero equals highest Name Event 10 Attrib Security Next Event None Stop Impulse Enable Logic Output Channel Device 2 3 4 5 6 7 Master Music Source Music 1 OK Cancel Type display the type of event you
97. acuation source Level dB when connected to DIVA you can adjust real time mode the level of the fireman microphone Volume dB indicates the current output level of the fireman microphone Clip Threshold dB allows to set the threshold point for the Clip indicator Level Overflow this is a LED indicators that light up when a too high level is detected on the fireman microphone Clip indicates when the signal is clipping Zone Release Time here you can set a time for which the manually zone selection is kept in memory Since this time has passed the next fireman microphone called will be routed in the pre define zone Push to talk with this option ticked you will need to keep the microphone button pressed in order to be able to talk Lock To Talk with this option ticked one pressure on the microphone button will start the call and one more pressure will stop the call For safe operations you can set a time after which the call is automatically stopped Enable Release Time ticking this option will stop the fireman microphone call after the amount of time defined This is used in order to avoid deactivation issue www ateis europe com Page 116 of 260 DIVA8 SYSTEM Fireman Mic Paging Event Fireman Mic Paging Event 8 Type Priority Name Attrib Next Event Start Impulse Enable Stop Impulse Device 120 2 Zero equals highest Security Logic Output Channel eng a
98. ailure M01 M AMP FAIL SXX M AMP FAIL XX 1 15 M01 M GAIN LOW SXX M GAIN LOW XX 1 15 M01 M GAIN HIGH SXX M GAIN HIGH XX 1 15 www ateis europe com If necessary exchange the unit The slave XX voice amplifier gain drops out of tolerance Action Check the slave XX voice amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The master voice amplifier gain is higher than tolerance Action Check the master voice amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The slave XX voice amplifier is higher than tolerance Action Check the slave XX voice amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The master music amplifier gain drops down to 0 Action Check the master music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The slave XX music amplifier gain drops down to 0 Action Check the slave music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The master music amplifier gain drops out of tolerance Action Check the master music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The sla
99. and loudspeaker lines and amplifiers monitoring A complete presentation of the software could be found here Software manipulation and configuration procedures could be found in the How to chapter Front panel The front panel is the center of stand alone operations It offers a complete set of indicators that shows the system status faults as well as audio activation It offers even more than just indicators using the navigation buttons in combination with the color screen DIVA8 G2T offers configuration changes and maintenance operation From the front panel one will also be able of starting evacuation alarm and a test messages with manual zone selection possibility as well as setting a music source routing All those features are completely compliant with the EN 54 part 16 More information about all the front panel manipulation could be find here Events DIVA is a multi functional device that can be use with several external sources and trigger commands In order to associate any action to a trigger command you will have to define Event One event can be compared to an action Each action or event can be started by different means external trigger modulation detection etc Those events are hierarchically organized by priority levels set for each one of them You also can set permanent event like playing music More information about Events can be found in the How To Use Events www ateis europe com Page 39 of 260
100. ange the PSSG2 unit PSSG2 color screen is Action Check PSSG2 condition Check the PSSG2 DIVA wiring path If necessary exchange the PSSG2 unit PSSG2 audio line is Action Check PSSG2 condition Check the PSSG2 DIVA wiring path If necessary exchange the PSSG2 unit defective defective defective Communication between DIVA master and PSSG2 EX microphone console has been lost Action Check PSSG2 E condition Check the PSSG2E DIVA wiring path Check PSSG2 E power supply If necessary exchange the PSSG2 E unit Embedded PSSG2 EX monitoring speaker is defective Action Check PSSG2 E condition Check the PSSG2E DIVA wiring path If necessary exchange the PSSG2 E unit PSSG2 EX microphone is Action Check PSSG2 E condition Check the PSSG2E DIVA wiring path If necessary exchange the PSSG2 E unit PSSG2 EX color screen is Action Check PSSG2 E condition Check the PSSG2E DIVA wiring path If necessary exchange the PSSG2 E unit defective defective Page 253 of 260 PSM CD16 faults PSM DISCONNECT PSM SPK FAIL PSM MIC FAIL PSM AUDIO FAIL Preset Table faults NO CONFIGURATION CFG CRC ERROR CFG VERSION ERR Evacuation inputs faults M01 EI X OPEN SXX EI Y OPEN M01 El X SHORT SXX EI Y SHORT www ateis europe com DIVA8 SYSTEM XX 1 15 1 9 XX 1 15 Y 1 9 Communication between DIVA master and master PSM microphone console has been lost Action Che
101. as reference for line A of one zone ReferenceB Ohm displays the value taken as reference for line B of one zone RefereneA B Ohm displays the value taken as reference for A and B in parallel Connected Source display the source connected to one zone Voice Amplifier Music Amplifier VO3 Tolerance here you can specify the tolerance wherein measurement has to stay before generating a fault state Measure Ohm displays the real time measurement of A and B in parallel Diff displays the difference in percent between Reference A B and Measure www ateis europe com Page 163 of 260 DIVA8 SYSTEM Zone Monitoring Controls Get Reference this button start the get reference process for one zone at a time Get all Reference this button start the get reference process for all zone Reset Reference this button allows to reset all reference stored Reset Monitoring this button allows to reset the monitoring in case of maintenance Tone Generator this button allows to set the tone generator settings You can learn more about tone generator by reading this Procedure to make references for one zone please follow the next steps Select a zone by clicking on the corresponding line e Press the Get Reference button Choose a tolerance value Procedure to make references for all zone please do so Press the Get All Reference Choose a tolerance value for each zone Note References should be taken only on
102. ata to display gt Seen G ce Once an Ethernet PSS will be found you will be able to use it in the configuration see How to Use Ethernet PSS 9 4 Set lp Address From the front panel of DIVA you can change the address from the LCD menu display In order to do this please read this DIVA s default IP address is 192 168 100 100 IP Submask and gateway address can also been changed from the software by going in the device search menu Tools gt Device Search Note you should be connected to the DIVA unit to be able to operate Ethernet setting changes www ateis europe com Page 58 of 260 DIVA8 SYSTEM Device Search Edit Search Group DIVA Machines Ethernet PSSs Name IP Address Subnet Mask Gateway Address Modify IP No data to display Auto Connect Manual Connect To modify the IP settings of the device please follow the next steps Click on the corresponding device Modify button t prompts you either if you want to continue or to cancel the modifying IP process This operation will modify IP configuration of machine Do want to continue Click OK the Modify Device IP window appears Modify Device IP Enable DHCP IP Address 192 SubnetMask 255 Gateway 192 www ateis europe com Page 59 of 260 DIVA8 SYSTEM In this window you can enable DHCP by ticking the correspondin
103. ate will start the update process Close closes the window General Display displays all the Ethernet PSS information as well as the update progression 9 14 Compile Compiling your current project will inform you in case of configuration errors or warnings In order to be able to store a configuration into DIVA you will have to compile your project first To compile go in the menu Operations gt Compile or Click on the Compile icon in the compile toolbar view picture below or even type F9 mE On the Status Bar you can permanently see the compile status of your project Compiled means the current state of your project have been checked Not Compiled means that your current project has not been checked 9 15 Store The store command menu Operations Store or the Store shortcut or even F8 open the store window see below www ateis europe com Page 75 of 260 DIVA8 SYSTEM To start storing click on the Store button A timeline display the status of the process The different states of the store process are written in the Store Status Area If not already log in DIVA software will ask you to enter a valid user name and password Once the store process is finished you will be prompt to e Connect to DIVA choose Yes or No e Enable Audio on DIVA choose Yes or No 9 16 Reverse The reverse command allows to download from DIVA to the software the current configuration stored into DIV
104. ateis europe com Page 97 of 260 DIVA8 SYSTEM Attrib here you can choose between security event or not See Common Option to learn more about the security option Next Event you can specify an event that will be started as soon as this event is finished Stop Event here you can select from the existing event list the event to be stopped 9 23 3 5 Stop Zone The Stop Zones event can interupt every paging music events in pre defined zone s Stop Zones Event Type Stop Zone Priority 20 lt ero equals highest Name Event 7 Attrib Security Next Event None Master 1 2 5 6 7 All Cancel Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Priority here you can choose a priority level for this event Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event is finished Zone Selection here you can choose in which zones lower priority events will be interrupted 9 23 3 6 Play Message Play message allows starting a message in pre defined zones after a trigger or starting a message in zones manually selected The Play Message event offers the possibility to set an output relay activation For more information about use of output
105. ating that the zone is occupied by a different process For more information about how to use the PSSG2 microphone console please read the PSSG2 user manual and the How to use PSSG2 microphone chapter 4 6 PSSG2 E The PSS G2E TCP IP Touch paging microphone console is a man machine interface which allows IP paging call messages broadcasting and DSP matrix parameter control DIVA8G2T can handle up to 8 PSS G2E units connected to an Ethernet network Its back lit touch screen is designed for simple and user friendly operating Various operating levels with password protection make the PSS G2E a versatile device that fits well in a commercial shopping center as for an industrial high security environment All paging parameters needed for site operating can be programmed zones assigned to the different buttons name of zones group of zones messages triggering levels adjustments and pre call chime A total of twelve keys on fourteen pages allow zone or group of zones selections Each key contains a color changing field indicating that the zone is occupied by a different process For more information about how to use the PSSG2 E microphone console please read the PSSG2 E user manual and the How to use PSSG2 E microphone chapter 4 7 CD16 207 0 0000100 e e e Wall mount heavy duty remote paging console with Access level 2 protection to comply with the EN 54 16 Compatible with DIVA8 System IDA4
106. can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event is finished Preset here you can specify the preset to be loaded www ateis europe com Page 95 of 260 DIVA8 SYSTEM 9 23 3 2 Logic Output As described before DIVA has 8 output channels that can be commanded by several trigger type When using the Logic Output Event you can associate to a trigger the closing of an output Logic Output Event Logic Output Priority Not Accessible Event 4 Attrib Security Next Event Hold Time 50 Ee EA ES eee Logic Output Master Channel Cancel Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event is finished Hold Time Ticking this option allows generating a pulse whose length can be defined from 50 to 60000 ms Logic Output here you can specify which output s you want to close when the event is triggered To learn more about output relay please read the How To Use Output Relay 9 23 3 3 Command String With this event you can send by RS232 commands to third party d
107. case of errors in this manual or not clear process description feel free to submit us mistakes suggestions or questions by sending an email This document intends to be a complete manual and ATEIS hopes that this Help file manual will provide you all information or answers needed However if you have any questions feel free to contact us 1 1 Ateis Presentation With more than twenty years of experience ATEIS has quickly established itself as a leading manufacturer of Public Address Voice Alarm systems and counter intercoms The constant growth of market share in Europe provides confirmation of the quality of ATEIS s commercial and technical approach Products The company now offers a full range of sound equipment microphones preamplifiers digital processors digital audio matrixes loud speaker monitoring systems amplifiers etc ATEIS designs and manufactures leading products in the voice alarm systems market which have been certified EN60849 compliant by the TUV Development Thanks to a development team that includes thirty engineers and to constant investment we are able to respond rapidly to the demands of our various markets with specific solutions and cutting edge technology We have distributors in more than fifteen countries in Europe and the Middle East with whom we have carried out major projects In choosing ATEIS you are guaranteed a trustworthy partner that can be counted on for the long term ATEIS Field ATEI
108. ck PSM cluster condition Check the PSMs DIVA wiring path Check PSM power supply If necessary exchange the PSM unit Embedded master PSM monitoring speaker is defective Action Check master PSM condition Check the PSM DIVA wiring path If necessary exchange the master PSM unit Master PSM microphone is defective Action Check master PSM condition Check the PSM DIVA wiring path If necessary exchange the master PSM unit Master PSM audio line is defective Action Check master PSM condition Check the PSM DIVA wiring path If necessary exchange the master PSM unit No software configuration is present in the DIVA unit Action Create and Store a configuration in the DIVA system Current DIVA configuration is corrupted CRC check code has changed Action Re store the configuration in the DIVA system Create and Store a new configuration in the DIVA system Current DIVA configuration has been made with a newer or a too old software version Action Create and Store a new configuration in the DIVA system Master evacuation input X contact line is defective the contact line is seen as an open line no contact Action Check the linked contact condition Check the contact wiring path Slave XX evacuation input Y contact line is defective the contact line is seen as an open line no contact Action Check the linked contact condition Check the contact wiring path Master evacuation input X contact line is d
109. closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones To learn more about output relay please read the How To Use Output Relay e Message by using the drop down menu you can select in the list of stored message a message to assign to the event e Play Mode by ticking continuous the message will be played until a trigger happen You can also specifiy a number of repeat time Conflict you can choose between Cancel All or Coexist Repeat Time if continuous not ticked you can choose a number of time this event will be repeated e Pre define Zone here you can specify the pre define zone s where the message will be played Zone Selection here you can specify the zone s where the call will be played Note Messages can only be seen if they are a part of the configuration Reading the message memory of the DIVA does not put messages in the configuration You ll have to reverse the messages in order to be able to use them in the configuration 9 23 3 7 Fireman Mic Paging A Fireman Mic Paging event can be declared in order to be used with any type of trigger www ateis europe com Page 100 of 260 DI
110. configure DIVA for Vox net or Modan you have to set parameters for RS 232 port 1 or port 2 of DIVA please read the Use RS232 Ports chapter First step configure the audio input that will be used for Vox net or remote access streaming In this tutorial we ll only use the two Music Sources www ateis europe com Page 194 of 260 DIVA8 SYSTEM enter the Music sources window by double clicking the music Icon on the Master window Music Source gt Modulation a Oa Kp meoo d acm 1000 L Ent e nni Defauit e Select for both source the vox net mode e Go into the menu View gt Vox Net Editing the following window should pop up www ateis europe com Page 195 of 260 DIVA8 SYSTEM VoxaNet Editing Parti Port2 Mode Point to point Mode Point to point Channel 1 Music 1 Note Each audio source Channel 1 None Note Each audio source can be only controled by can be only controled by Channel 2 Music 2 one channel Channel 2 None one channel Channel 3 None Channel 3 None Zones Master 1 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 In the mode drop down menu select Point To Point under the corresponding RS 232 port In the Channel 1 drop down menu select Music 1 In the Channel 2 drop down menu select Music 2 In zone codes area create your audio routing corresponding to code received maximum code number 64 Exam
111. d Microphone Calls From the front panel you have the choice two start three different messages or do a zone call with the fireman microphone Read the following two chapters for more information about how to set up messages and how to configure the Fireman Microphone There are three front panel message buttons plus one reset button EVAC initiates a evacuation message broadcasting process ALERT initiates a evacuation message broadcasting process e MSG TEST initiates a evacuation message broadcasting process RESET initiate a software reset process 8 3 1 1 Messages Depending on the software configuration created there is two distinct way of starting a message with manual zone selection or with pre defined zone To learn more about how to set pre defined zone on message please read the www ateis europe com Page 48 of 260 DIVA8 SYSTEM How to set up front panel messages chapter Starting message with Pre define zone s From EVAC button Liftthe button cover Press the EVAC button DIVA displays EVAC KEY PROCESS Press OK DIVA displays EVAC CONFIRM 1 SURE OK ESC Press OK DIVA displays EVAC CONFIRM 2 SURE OK ESC Press OK The message is played in the pre defined zone s 0000000 0 From ALERT button o Press the ALERT button DIVA displays ALERT KEY PROCESS Press OK DIVA displays ALERT COMFIRM 1 SURE OK ESC Press OK DIVA displays ALERT CONFIRM 2 SU
112. d maintenance operations guide should cover most of the situation However some general troubleshooting advices could be found prior the fault list chapter 14 1 DIVA8 Power LED is OFF e sure the wire path between BECS and DIVAS is in good condition e Make sure the BECS is correctly connected to the DIVAS unit e If still no power LED lit please contact your ATEIS dealer 14 2 DIVA8 Power LED is ON but DIVA8 doesn t boot e Disconnect and reconnect the power supply connecter e fthe DIVAS still cannot boot please contact your ATEIS dealer 14 3 DIVA8 display is blocked e Disconnect and reconnect the power supply connector e f nothing helps pleas contact your ATEIS dealer 14 4 The TCP IP connection between computer and DIVAS can t be made e Verify your computer network card settings e Verify DIVA8 Ethernet settings e Try to use the MANUAL CONNECT option in the Search Device window e Verify that the switches on the Network allow you to use the DIVA communication port e Verify Windows firewall settings e f nothing helps please contact your ATEIS dealer 14 5 No Audio is coming out of speaker lines e Verify that amplifiers are correctly connected to the DIVA8 e Verify that speaker line connectors are correctly engaged e Verify that amplifiers are turn ON and are in good condition e Verify that audio is coming out of the DIVA8 OdB output e f nothing helps please contact your Ateis dealer 14 6 Fault List and
113. e Preset List opens the preset list sub window see Property Control Section e LED Display opens the sub windows where the front panel LEDs are replicated see Property Control Section e System Status open the system sub window where all the related logfile action can be found see Property Control Section Event opens the Event Manager window see how to use events www ateis europe com Page 30 of 260 DIVA8 SYSTEM e Message opens the Message Manager window see how to add messages into DIVA Scheduler opens the Scheduler window see how to use the scheduler GPIO opens the logic inputs outputs configuration window see how to use logic inputs e Evac Configuration Opens the Evac configuration window see how to use evac configuration e Vox Net Editing opens the Vox Net editing window see how to put DIVA in Vox Net e LCD Language under construction Toolbars Within this menu subgroup you ll find all the toolbars available in DIVA software gt Edit gt Compile gt Preset gt Control gt Lock Design gt Help gt Windows gt Music Operations Tools System Preset List LED Display System Status System Event Message Scheduler GPIO Note Drag DIVA devices here Evac Configuration Yox Net Editing LCD Lanquage Compile Preset Control Lock Design Help Windows Music Operation 6 2 4 User Here you ar
114. e able to manage the user right add users with a password and restrict access only to needed features www ateis europe com Page 31 of 260 DIVA8 SYSTEM Operation Tools Lc e User Management Calls the User Management window to set up users or user groups and their individual privileges Logout Opens the User Login window For more information about the user management see how to use the user management 6 2 5 Operation Here you can find all data communication commands eration Tools Lock Set Date Time e Set Date Time Allow user to set the time and date of the DIVA unit Set Store Password Offers a store process protection password management Compile Compiles the current configuration and displays eventual errors Store Upload configuration parameter into the DIVA s parameter memory Reverse Downloads the DIVA configuration in the computer Connect Establishes data connection to the machine s in order to monitor or adjust parameters online Disconnect Disconnects DIVA software from the machine s Audio Enable Enables DIVA s audio processing Audio Disable Disables DIVA s audio processing e Stop All Events Stops all running events e Music 1 On enable music sources one routing Music 1 Off disable music sources one routing e Music 2 On enable music sources two routing Music 2 Off disable music sources two routing 6 2 6 Tools Here you w
115. e below New Event Master Select Master 1 Event Type Music On In order to select an event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the event created with the logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this When logic input use event to control music sources you can find a list of logic input associated to music source on the music source window in Logic Input drop down menu www ateis europe com Page 126 of 260 DIVA8 SYSTEM Logic Input Input Select Default Source 9 26 6 Software Control The DIVA software allows to control and monitor music sources Once you have enter the music source window by double clicking on the music source icon you will be able to read and control some parameters right part of the window see below Logic Input Normal Input Channel 1 Music ON Normal Input Channel 2 Music OFF Level dB when connected to DIVA you can adj
116. e selector at their right ID The events created are identified with one number the ID number Name displays the event s name You can specify a name for an event when editing the event By default the name is set to Event X Priority displays the priority level of an event Security displays if the event is a security one or not Type displays the type of the event Next Event displays which event is called after this event Time if an event loop has been created displays the number of time the loop is made Link By displays the trigger that will activate the event Select All select instantaneously all events in the list Select None deselect instantaneously all selected events www ateis europe com Page 90 of 260 DIVA8 SYSTEM Delete delete selected event from the list Event Type here you can select the event type that you want to create This have to be made before press the Add button Add after the event type selection pressing the Add button will create the new event in the list Edit after creating an event you will have to edit all its parameters By clicking the edit button you will enter the different event setting windows Close closes the Event window There are different types of event and here is a list of all events that can be created Note some event created by accessing the music fireman microphone and MIC LINE windows are automatically named and offer settings that could dif
117. eaker gain dB when connected to DIVA you can adjust real time mode the gain of the PSS internal speaker Volume dB indicates the current output level of the music source Clip Threshold dB allows to set the threshold point for the Clip indicator Mic Overflow this is a LED indicators that light up when a too high level is detected on the PSS microphone Speaker Overflow this is a LED indicators that light up when a too high level is detected on the PSS speaker Clip indicates when the signal is clipping 9 27 2 Keys Page The Key page is where you will define keys for the PSS and their associated action Depending on the PSS model you can specify up to 96 keys so 96 actions www ateis europe com Page 131 of 260 DIVA8 SYSTEM PSS PSS Page 1 Key 1 123 Zone Selection v Zone Selection X Zone Selection RE Zone Selection v Edit Edit Edit Edit Key S ndi 3 Key 5223 Zone Selection Zone Selection Zone Selection Edit Edit It s important to notice that you can only visualize 12 key at the same time To see up to 96 keys you have to jump to pages with the drop down menu at the upper left corner You also can cut copy paste and delete keys with the upper corresponding button In order to create a key follow the next few steps In the three square enter a key label 3x 6 digits e With the drop down menu select a key type some keys type
118. efective the contact line is seen as an shorten line short circuit on contact Action Check the linked contact condition Check the contact wiring path Slave XX evacuation input Y contact line is defective the contact line is seen as an shorten line short circuit on contact Action Check the linked contact condition Page 254 of 260 DIVA8 SYSTEM Fault inputs action M01 EFI X ACTION X 1 2 SXX EFI Y ACTION XX 1 15 Y 1 2 Flash memories faults MSG FLASH FAILED CFG FLASH FAILED PGM FLASH FAILED General disfunction and maintenance operations DIVAs system has no power LED lit DIVA system LEDs test www ateis europe com Check the contact wiring path Master evacuation fault X has been triggered Action Check the fault input wiring path Check the connected device condition If necessary exchange the connected device Slave XX evacuation fault Y has been triggered Action Check the fault input wiring path Check the connected device condition If necessary exchange the connected device Message flash memory is defective Messages cannot be played Action Please contact your Ateis dealer If necessary exchange the DIVA unit Configuration flash memory is defective Configuration cannot work properly Action Please contact your Ateis dealer If necessary exchange the DIVA unit Program flash memory is defective DIVA cannot Work properly Action Please contact your At
119. eis dealer If necessary exchange the DIVA unit The DIVA system is not properly connected to a power source or internal fuse is broken Action Check power supply condition Check power supply signal path Please contact your Ateis dealer If necessary exchange the DIVA unit From time to time please start a DIVA system LEDs test For more information on how to perform a LEDs test please read the LEDS LOGIC TEST chapter Page 255 of 260 DIVA8 SYSTEM 15 LCD Messages List DIVA displays several different string on its LCD screen Here is a complete list with short description EVACUATION REPORT Displayed when an evacuation state is activated FAULTS REPORT D Oo isplayed when a fault state is activated Menu level 0 SELECT DISPLAY E F E E Displayed as a validation when the evacuation process has been initiated ALARM CONFIRM Displayed as a validation when the alert process has been initiated T EVACUATION LIST Displayed above the different evacuations process listed D U U isplayed above the different faults listed EST CONFIRM Displayed as a validation when the test process has been initiated AULTS LIST F VENTS LIST Displayed above the different events listed FUNCTIONS MENU Displayed when accessing the functions menu i L __ IUSERLOGOUT Displayed when accessing user logout menu LOG RECORD Displayed when accessing log record menu SET SYSTEM TIME
120. ending on the configuration needed you can use the amplifier fault output to force DIVA to enter security mode in case of amplifier failure To achieve this aim simply connect the DIVA EXFLT connector to the amplifier s FAULT connector To learn more about amplifier connection please refer to the amplifier manual 12345 6 amp ofeessJo www ateis europe com Page 208 of 260 DIVA8 SYSTEM 9 47 10 Speaker Lines In order to have a high accuracy on impedance measurement you should add an end of line capacitor on each speaker line If help is needed to know the value of those capacitors please take contact with Ateis When connecting speakers take care of the polarity End of line Capacitor 100V Line A 100V Line B End of line Capacitor www ateis europe com Page 209 of 260 DIVA8 SYSTEM 9 47 11 Normal Logic Inputs Normal logic inputs have been designed to work with simple contact or button Follow the next schematic to connect a contact to a normal logic input 9 47 12 Evacuation Inputs The evacuation input can be used in three different modes contact monitored contact and UGA The three uses are represented on the schematic below To learn more about how to perform a monitorable contact please read this Monitored Contact mode Normal contact mode www ateis europe com Page 210 of 260 DIVA8 SYSTEM 9
121. er Take new references for the line Reset monitoring Master zone X line B impedance is higher than 5kOms The corresponding speaker line is seen as OPEN Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line B impedance is higher than 5kOms The corresponding speaker line is seen as OPEN Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Master zone X line B impedance is under 4 Ohms The corresponding speaker line is seen as shorten Action Check the corresponding impedance real time measurement in the software monitoring window Page 251 of 260 SXX Z Y B SHORT Fireman microphone faults FMM AUDIO FAIL FMM KEY OPEN FMM KEY SHORT EVAC button faults EVAC KEY OPEN EVAC KEY SHORT ALERT button faults ALERT KEY OPEN ALERT KEY SHORT MSG TEST button faults TEST KEY OPEN TEST KEY SHORT ALLCALL button faults www ateis europe com DIVA8 SYSTEM XX 1 15 Y 1 8 Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line B impedance is under
122. er supply monitoring mode for the master and each slave DC 24V or AC 230V www ateis europe com Page 84 of 260 Master 1 Note Drag Audio sources here Voice Amp Music Amp DIVA8 SYSTEM Front Panel Setup Ethernet PSSs Master Slave Slave 2 Slave 3 Slave04 Slave 5 Slave 5 SlaveD Dor Slavel8 Slave09 Slave10 Slavel1 Slavel2 Slave13 Slave14 Slave15 To activate or deactivate the DC monitoring simply tick or untick the corresponding device DC checkbox To activate or deactivate the AC monitoring simply tick or untick the corresponding device AC checkbox www ateis europe com Page 85 of 260 DIVA8 SYSTEM 9 22 Add Messages Into DIVA In order to store messages into DIVA memory you have to use the message manager window Go under menu View gt Message The message window will pop up see below In the upper part of the Message window you can select the DIVA master unit you want to work on for messages Message Manager Local Memory Preparing List Stored List Message Name _ MessageName 5s LevelAdustment Current Message Level 0 gt Play E Stop Save Level Master 1 All epee eae ES EE p General Operation General Operation Select All Store Select All_ Read MSG Lib psu
123. ere you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms ACK Relay you can specify here an logic output channel that will be closed when the event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones Set the play message event option to suit your needs The bottom part of the Evac Configuration form is dedicated to create the phase evacuation After having enabled an evacuation input you have to define in which zones the messages will be played e For each evacuation input CH1 to CH8 select the routing of Evac event and Alert event by clicking into the boxes see next picture www ateis europe com Page 158 of 260 DIVA8 SYSTEM Evac Configuration Events Device Selection Master 1 Edit Evac Event
124. es In order to do so you have to define PSS keys to suit your need See How To Use PSS Microphone to learn more about the PSS Note Routing music from the PSS can only be operated if the music source mode is Route Key PSS keys for music operations can be set to different type using the drop down menu see below www ateis europe com Page 122 of 260 DIVA8 SYSTEM e Zone Selection By creating a Zone Selection key you can make a selection of zones in which music will be routed Note Zone Selection keys are not exclusively for Zone selection for paging music zone keys are made the same way As soon as you select Zone Selection a new Zone Selection window will pops up In this window choose the zone s to associate to the key see below Zone Selection pater FEE a ojojojojojojojojo e Music Source Selection When creating a Music Source Selection key you will have to choose between music source 1 and music source 2 with the Key Setting pop up window www ateis europe com Page 123 of 260 DIVA8 SYSTEM f Key Setting SEE This type of key is used as the front panel select button You have to select the music source before you can route it to some zones Note this key is not a music source toggle type you will have to create two music source selection keys in order to be able to route both sources e Route The ROUTE key acts e
125. event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay e Music Source here you can choose the music source you want to switch on Zone Selection here you can specify the zone s where the music will be activated www ateis europe com Page 107 of 260 DIVA8 SYSTEM 9 23 3 12 Music OFF By Zones The Music Off By Zones event allows to stop music source 1 or 2 with any type of trigger in pre defined zone s Music Off By Zones Event Type Music Off By Zones Priority 20 lt ero equals highest Name Event 13 Attrib Security Next Event None Stop Impulse Enable 11213 4 5 6 7 8 Master Music Source Music 1 Master 1 All c jee ee iv OK x Cancel Type display the type of
126. event is active Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is active in one of the pre define zones To learn more about output relay please read the How To Use Output Relay Conflict you can choose between Cancel All or Coexist Pre Chime Before a call you can add a chime message Here if Pre Chime Enable is selected you can select which message will be used as pre chime e Post Chime After a call you can add a chime message Here if Post Chime Enable is selected you can select which message will be used as post chime e Pre define Zone if ticked you can choose pre defined zone with the zone selector Zone Selection here you can specify the zone s where the call will be played 9 23 3 11 Music ON By Zones The Music On By Zones event allows to start music source 1 or 2 with any type of trigger in pre defined zone s www ateis europe com Page 106 of 260 DIVA8 SYSTEM Music On By Zones Event Type Music On By Zones Priority 20 lt ero equals highest Name Event 12 Attrib Security Next Event None Stop Impulse Enable FTE ET ERE CUT EI EC d Master Music Source Music 1 Master 1 All Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the
127. event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay e Music Source here you can choose the music source you want to switch off www ateis europe com Page 108 of 260 DIVA8 SYSTEM e Zone Selection here you can specify the zone s where the music will stop playing 9 23 3 13 Toggle Music ON OFF The Toggle Music On Off event have been created to turn music on or off with one same trigger As example using a contact one closing will switch on music one more closing will switch off music Toggle Music Event Type Toggle Music On Off Priority 20 lt ero equal
128. evices Valid commands are described in the Communication Protocoles chapter www ateis europe com Page 96 of 260 DIVA8 SYSTEM F Command String Event Type Command String Priority 20 zi Not Accessible Name Event 5 Attrib Security Next Event 4 Starting Command Stopping Command Port Number 1 Cancel Type displays the type of event that is created in this case Load Preset Name here you can specify a name for the event created Attrib here you can choose between security event or not See Common Option to learn more about the security option e Next Event you can specify an event that will be started as soon as this event is finished Starting Command here you can type in the command to be sent at the event activation Stopping Command here you can type in the command to be sent at the event deactivation Port Number here you have to specify on which RS232 port the command have to be sent 9 23 3 4 Stop Event This event have been created in order to be able to stop any event by the means of a trigger Stop Event Event Type Stop Event Priority 20 I Zero equals highest Name Event B Attrib Security Next Event None Stop Event None Cancel Type displays the type of event that is created in this case Load Preset e Name here you can specify a name for the event created Priority here you can choose a priority level for this event www
129. f authority Level 4 E Level 1 is the hightest level Press Next to continue Press Back to go back to previous step e Select an Level for this user account explanation on user level can be found here www ateis europe com Page 67 of 260 DIVA8 SYSTEM e Click Finish to finish the process Click Back to go back to the previous step 9 10 2 Delete User account User Management Salt AccountName Level Authority Level ATEIS1 Lowest ATEIS2 Mid ATEIS3 High ATEIS4 Highest Delete Add 4 Edit EF Close Select an account in the list of the User Management by ticking the corresponding check box e Click on delete e jt will prompt you Delete User account click OK to delete or Cancel to stop the delete process 9 10 3 Explanation on User Level In order to comply to the European standard EN 54 16 the user level have been set as described e Level 1 is the lowest level Level 1 has the right to use real time software control music level filters and PEQ real time front panel control music level speaker level and indicators Level 1 is always accessible without password Can do reverse procedure and connect from software e Level 2 is defined to be for person having a specific responsibility for safety Level 2 has all right except O Storing config messages o Change Ethernet settings To enter level 2 a password is needed e Level 3 is for specific main
130. f maintenance The gain value are absolute gain A gain of 100 correspond to a gain of 40 dB Procedure to take amplifiers references Press the Get Reference button www ateis europe com Page 165 of 260 DIVA8 SYSTEM Choose a tolerance value Note music amp monitoring tab offers exactly the same displays and controls 9 35 3 Leakage Impedance The DIVA8 has a special measurement unit that checks the impedance between the amplifier OdB output and amplifier 100V input If these impedance goes lower than the value set as threshold DIVA displays a fault Monitor Device Master 1 y Leakage Impedance Threshold ohm Leakage Impedance Measure ohm e Leakage Impedance Threshold Ohm here you can specify in Ohms the leakage impedance threshold By default the leakage impedance threshold is set to 5MOhm In old buildings sometimes this threshold has to be be adjusted e Leakage Impedance Measure Ohm displays the current leakage impedance value www ateis europe com Page 166 of 260 DIVA8 SYSTEM 9 36 Use the Scheduler To access the Scheduler window go on the menu View gt Scheduler The window below should appear Scheduler Master Master 1 A Task 1 2010 08 02 14 35 Master this indicates the device on which the scheduler task will happen e ID displays the ID number of the task e Name display the scheduler task name This name can be
131. fer from those described in this chapter Load Preset Logic Output Command String Stop Event Stop Zone Play Message Fireman Mic Paging MIC LINE Paging Music ON Music OFF Music ON By Zones Music OFF By Zones Toggle Music ON OFF Toggle Music ON OFF By Zones Security Mode Stop All Event Silence Zone Event 9 23 1 Common Options Security Option The Security option is common to all event type If the security option is selected this event will be able to be started when DIVA has entered the security mode This mode have been created to enter a power safe mode in case of power supply failure in order to save energy when supply by emergency battery This mode is automatically launched when using External Fault Inputs Evacuation Option The evacuation option is offered on all play message type of event and on all event related to audio sources This option is only accessible after having selected the Security option In fact an event could only be an evacuation event if it is already a security one The evacuation option allows the event to be understood by the machine as an evacuation occurrence For instance a play message event with the evacuation option defined will light up the front panel EVAC LED instead of the PAGE LED Zone Selection In many event you will be able to choose some pre defined zones Here is the zone selector display and explanation www ateis europe com Page 91 of 260
132. g check box Enter the IP address value Enter the Subnet Mask value Enter the Gateway value Click OK If not already logged in it will prompt you to enter an username and password System will reboot automatically Note you have to keep in mind that setting TCP IP parameters not related to the one set for your network card could lead to communication problems 9 5 Save Open The Save Open procedure is quite identical to most of the Microsoft Windows based software The icon used as well as keyboard shortcuts are well known for Microsoft Windows users Here you will find procedures to Open afile e Save a file e Save a file as e Set an Autosave process 9 5 1 1 Open Open a DIVA file Click on the Open Icon Highlighted in picture below in the Edit toolbar or go to menu File gt Open or even press ctr o WF 4 S7 9 5 1 2 Save Save a DIVA file Click on the Save Icon Highlighted in picture below in the Edit toolbar or go to menu File gt Save or even press cb I X i o The first time you will be saving a project you will be prompt to enter a name for that file The Save command is used to save current project under the current name Note DIVA s configuration files are saved in diva extension 9 5 1 3 Save As The Save As option can be used to save a configuration under a different name Simply go to the menu File Save As 9 5 1 4 Autosave In the Options page under File tab
133. ge 150 of 260 DIVA8 SYSTEM 9 32 1 Normal Logic Inputs To access the Logic Inputs window go to the menu View gt Logic Inputs Then click on the Normal Logic Inputs tab Logic Inputs Normal Logic Inputs Evacuation Inputs External Fault Inputs Name Normally Close Open Latch Event Setting Channel 1 Normally Open Channel 2 Normally Open Channel 3 Normally Open Channel 4 Normally Open Channel 5 Normally Open Channel 6 Normally Open Channel 7 Normally Open Channel 8 Normally Open DIVA Machine Master 1 Name Here you can specify a name by simply clicking in the box Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact is open in neutral position Latch Mode By ticking this option you will set the contact to be in latch mode It means that you will need on trigger to open close the contact and one more trigger to get it back to the neutral position Event Setting By clicking start you will be able to associate an event to this input 9 32 2 Evacuation Inputs Evacuation input have been design to offer monitoring on logical inputs as well as UGA mode even though they can be used as normal logic inputs in order to provide an higher security level for external trigger Logic Inputs d Eg Normal Logic Inputs Evacuation I
134. gout In case of multiuser levelling you can logout from the current user session in order to login in an other one From the FUNCTIONS MENU e Use arrow keys to access the USER LOGOUT menu e Press OK it will display Sure OK ESC Press OK o You will be prompt to login o Enter your user name o Enter your password o You will be log in your user account Press ESC to go out of the menu 8 1 4 3 Log Record In the menu section of DIVA you can read the Log File as well as clear it if needed To read the Log File From the FUNCTIONS MENU Use arrow keys to access the LOG RECORD menu Press OK e Use arrow keys to display different Log Files occurrences Note first occurrence displayed is the the latest log file occurrence Log File occurrence are displayed in the following way m First line occurrence number and date XXXX yy mm dd m Second line time and status Start end hh mm ss Status Press OK Log File entry is displayed in plain text on two lines Press Up arrow or Down Arrow keys to go to the previous next log file occurrence Press ESC to go back to the Log Record menu For a complete list of Log File entry please read the Log File Messages List chapter To clear the current Log File From the FUNCTIONS MENU Use arrow keys to access the LOG RECORD menu Press OK Use arrow keys to access Clear Log Files submenu If you want to delete the Log Files Press OK You will be asked for
135. he FUNCTION MENU Use arrow keys to access the LOG RECORD menu Press OK Use arrow keys to access Clear Log Files submenu If you want to delete the Log Files Press OK You will be asked for validation SURE OK ESC If Yes Press OK If No Press ESC 9 48 2 From Software In the software the log file is accessible either by the menu View gt System Status gt Log or directly by moving the mouse on System Status icon in the Property Control Section bar see below www ateis europe com Page 217 of 260 DIVA8 SYSTEM om Message stated Date Log Record Limit 20 In the Log tab you will be able to export read Log File and clear the Log File display Export Log exports the Log File into txt file Clear deletes the entire Log File content Read log clears the Log File software display Log Record Limit specify the number of Log file occurrence displayed In order to read the log file entries click on the Read Log button Note to be able to read the log file you have to be real time connected If an incident is recorded it will appear as shown in the following picture System Status m Message i Stated Dae Time 1 Slave 1 Disconnect End 2010 11 23 22 56 43 2 Slave 1 Disconnect Start 2010 11 23 22 56 43 3 Slave 2 Disconnect End 2010 11 23 22 48 39 Log Record Limit 20 S Slave 2 Disconnect Start 2010 11 23 22 48 39 5 Slave 2 Di
136. he end of the Master Slave system Slave ID This rotary switch is used to set an ID to each Slave in the system Logic output Eight Logic outputs to send a pulse or a static closing opening to an external device www ateis europe com Page 18 of 260 DIVA8 SYSTEM 4 External Devices This chapter will quickly describe the external devices that could be connected to a DIVA unit It won t speak about external contact or button that also could be used For more information about those devices please visit ATEIS website 4 1 Fireman Microphone The Fireman Microphone SHM 1 is a small compact microphone dedicated to security calling It is a totally monitored microphone with internal resistor network to detect four different states Shortcut Closed Contact Open Contact Absent Firemen Microphone SHM 1 for All call group or zone calls The EN 54 surveillance is realised thanks to the DIVA internal circuitry 4 2 PSS The PSSDT touchscreen paging microphone can be configured either using a PC computer or by using control keys and the front LCD screen of the SINAPS module to which it is connected Access can be password protected All parameters needed for site operating can be programmed zones assigned to the different buttons name of zones zone groups priorities access to different messages levels adjustments pre call chime press to talk music ON OFF and music routing Its large LCD screen provides a
137. he logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this When logic input have set for Mic Line source you can find a list of logic input associated to Mic Line source on the www ateis europe com Page 147 of 260 DIVA8 SYSTEM Mic Line window in Logic Input drop down menu Normal Input Channel 1 Paging 9 31 3 From Software The DIVA software allows the control and the monitoring of the Mic Line source Once you have entered the Mic Line window by double clicking on the Mic Line icon you will be able to read and control some parameters right part of the window see below Level dB when connected to DIVA you can adjust real time mode the level of the music sources Volume dB indicates the current output level of the music source Clip Threshold dB allows to set the threshold point for the Clip indicator Level Overflow this is a LED indicators that light up when a too high level is detected on the music source Signal indicates the presence of audio signal Clip indicates when the signal is clipping Phantom Power add the phantom power to the Mic Line input Mic Line www ateis europe com Page 148 of 260 DIVA8 SYSTEM 9 32 Use Logic Inputs Logic inputs are a way to start any type of event with
138. here ay Master 1 B Connection 88 Fault B Evac 0 Modified Not compiled f presetust Wii Once the new project is launched you will need to set up the network options as well as the correct IP address see How To Configure Network Option and How To Set IP Address www ateis europe com Page 63 of 260 DIVA8 SYSTEM By double clicking the DIVA icon you will enter the master window page see below Master 1 Note Drag Audio sources Yoice Amp Music Amp In the Master window you will be able to add design components set speakers parameters for DIVA and PSS Set system options Set system power monitor Access to the slave unit configuration Access the front panel configuration window Access the monitoring window Access to the Ethernet PSS configuration Window Access to the Vox Net paging configuration Set RS232 Port 1 and 2 communication parameters www ateis europe com Music 1 Enable Music 2 Enable Mic Line Enable Message Enable Fireman Enable PSS PSM Enable HEr Machine 55 5 Page 64 of 260 DIVA8 SYSTEM 9 9 Setup System Options The DIVA application software offers general system options Once a new project is created you will find those options on the Master 1 configuration window under System Options tab f Master 1 Note Drag Audio sources here Speaker Parameters System Op
139. ick if ticked to activate a PSS key you will need to press it twice Chime selection Pre allows to add a chime message at the beginning of a microphone call Simply choose the pre chime message from the drop down menu Post allows to add a chime message at the end of a microphone call Simply choose the post chime message www ateis europe com Page 130 of 260 DIVA8 SYSTEM from the drop down menu Selected Messages Message 1 to Message 4 with the use of the drop down menu you can add to the PSS up to 4 event buttons that will launch the corresponding selected events This option is restricted for message type event The play message event can be reached using the MSGs key on the PSS Monitoring Pre Amp virtual LED that will light up in case of PSS microphone pre amplifier failure SPK Cable virtual LED that will light up in case of PSS integrated loudspeaker connection failure MIC virtual LED that will light up in case of microphone capsule issue MIC Out virtual LED that check the state of the microphone output LCD virtual LED that indicates any LCD screen fault Keyboard virtual LED that light up in case of touchpad issue MIC Cable virtual LED that will light up in case of microphone cable issue Missing virtual LED that light up if the PSS is not plug into DIVA Controls and Indicators Mic gain dB when connected to DIVA you can adjust real time mode the gain of the PSS microphone Sp
140. ill find command related to communication with DIVA units www ateis europe com Page 32 of 260 DIVA8 SYSTEM ools Lock Window Device Search Options F12 Update Will update the DIVA Firmware to the one corresponding to your current software version see how to update DIVA NOTE Upgrading from a too old version to the current one could cause configuration files compatibility issues e Device Search Will search and display all the DIVA Master IP connected to the TCP IP network see how to search device Language under construction Options Will open the Options window in which you will be able to set network parameters as well as software colour scheme and autosave function See Pictures below 6 2 7 Lock The Lock menu allow you to lock the software with a password in order to avoid another user to manipulate your configuration ck Window Help Lock Set Password e Lock Locks the software Note if no password were specified every user can unlock the software Set Password Offers the possibility to set a password for unlocking the software If set as soon as you press the unlock button it will prompt you to enter the last password set 6 2 8 Window This menu provides window arrangement commands and quick access to open design or component control windows GA Cascade Shift Ctrl F2 Tile Shift Ctrl F3 E Arrange icons Shift Ctrl F4 1 System
141. in To Low S01 V GAIN LOW Slave 01 Voice Amp Gain To Low S15 V GAIN LOW Slave 15 Voice Amp Gain To Low Voice Amp Gain To Hiaht MO 1 V GAIN HIGH Master Voice Amp Gain To Hight S01 V GAIN HIGH Slave 01 Voice Amp Gain To Hight 15 V GAIN HIGH Slave 15 Voice Amp Gain To Hight MO1 M AMP FAIL Master Music Amp Fail S01 M AMP FAIL Slave 01 Music Amp Fail 15 M AMP FAIL Slave 15 Music Amp Fail MO 1 GAIN LOW Master Music Amp Gain To Low 501 M GAIN LOW Slave 01 Music Amp Gain To Low 515 M GAIN LOW Slave 15 Music Amp Gain To Low Amp Gain To Hight MO 1 M GAIN HIGH Master Music Amp Gain To Hight S01 M GAIN HIGH Slave 01 Music Amp Gain To Hight 15 M GAIN HIGH Slave 15 Music Amp Gain To Hight MO1 FAIL Master Vo3 Fail 501 FAIL Slave 01 Vo3 Fail 515 FAIL Slave 15 Vo3 Fail www ateis europe com Page 243 of 260 DIVA8 SYSTEM Zone Line A Impedance Master Zone Line A Impedance MO1 Z 1 A IMPEDE Master Zone 1 Line A Impedance MO 1 2 8 A IMPEDE Master Zone 8 Line A Impedance Slave 01 Zone Line A Impedance S01 7 1 A IMPEDE Slave 01 Zone 1 Line A Impedance 501 Z 8 A IMPEDE Slave 01 Zone 8 Line A Impedance Stave 15 Zone Line A impedance 15 7 1 A IMPEDE Slave 15 Zone 1 Line A Impedance 515 Z 8 IMPEDE Slave 15 Zone 8 Line A Impedance Zone Line A Open Master Zone Line A Open MO1 Z 1 A OPEN Master Zone 1 Line A Open MO1 2 8 A OPEN Master Zone 8 Li
142. ine Page 250 of 260 M01 Z X A SHORT SXX Z Y A SHORT Speaker line B faults 1 Z X B IMP SXX Z Y B IMP M01 Z X B OPEN SXX Z Y B OPEN M01 Z X B SHORT www ateis europe com DIVA8 SYSTEM XX 1 15 Y 1 8 XX 1 15 Y 1 8 XX 1 15 Y 1 8 Reset monitoring Master zone X line A impedance is under 4 Ohms The corresponding speaker line is seen as shorten Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line A impedance is under 4 Ohms The corresponding speaker line is seen as shorten Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Master zone X line B impedance is out of tolerance Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line B impedance is out of tolerance Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speak
143. ings without selecting it from the Menu Bar The control panel will automatically slide down again if you move the cursor out of it s space giving again the whole view to the Design View Area The two accessible sub bar windows are listed below e System Status Gives access to Log files management as well as project build historic System Status Log Build l Export Log ee 1 Slave 1 Disconnect 2010 11 23 22 56 43 e Clear 9 Read Log 2 Slave 1 Disconnect Start 2010 11 23 22 56 43 3 Slave 2 Disconnect End 2010 11 23 22 48 39 Log Record Limit 20 4 Slave 2 Disconnect Start 2010 11 23 22 48 39 5 Slave 2 Disconnect End 2010 11 23 21 57 17 6 Slave 2 Disconnect Start 2010 11 23 21 57 17 _ ES Preset D Display 9 System Status e LED Display offers real time status LED display only if connected to DIVA units It is a replic of the front panel LED display www ateis europe com Page 37 of 260 DIVA8 SYSTEM NETT NEN NE EE Fe ee ee ee Evac Master 1 ug 2 2 a 3 Ca a 2 Slave 01 B a B 3 Fault Alarm Slave 02 B 3 a B 2 a Paging Slave 03 B m 2 2 ca c3 Ca ca Music Preset List shows all parameters controlled in the preset selected drop down menu Preset List parameter Master Component
144. ink to the corresponding fault input To do so please refer to the How To Use Logic Inputs chapter 9 23 3 16 Stop All Events This event has been design to stop all events that are currently running in the system with one trigger action Stop All Event Type Stop All Event Priority 20 lt ero equals highest Name Event 16 Attrib Security Next Event None X Cancel Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option www ateis europe com Page 111 of 260 DIVA8 SYSTEM Next Event here you can select the event to start after the current one is finished 9 23 3 17 Silence Zone Event The Silence Zones Event allow user to mute the audio in zone s without affecting the zone state evacuation or alert page This is a common way for firemen to stop the evacuation message when a building is empty Silence Zones Event Type Silence Zone Priority 20 lt ero equals highest Name Event 7 Attrib Security Next Event None Master 1 Slave 01 1 All 2 5 6 7 2 3 4 5 6 7 display the type of event you are creating or modifying Name here
145. is europe com Page 15 of 260 DIVA8 SYSTEM Alert and Test message buttons Starts messages in manually selected zones or in pre defined set of zones Zone attenuator knobs Eight zone signal attenuators are available on the master DIVA8 Independent zone music level can be set for the eight master zones Zone selection buttons Select or deselect zone for manual routing DIVA8M Rear View Logic and Extemal 3 4 vac Logic amp Evacuation 100V Signal Amplifiers RS232 Ethemet Outputs Fault Inputs Links OUT y o Connector ff Connector Contact Fault inputs Speaker PSS PSM Master Remote Mic Line Music externa Backup Zone Connector Slave Link Ext Input Inputs Fireman Power Outputs Connector P P Mic Input input Logic and external fault inputs There is eight logic inputs that are two states input open contact close contact External faults input are normally reserved to connect security devices like monitored power supply Those two inputs can be used to put DIVA into a security mode security mode will be discussed in the event chapter Logic output Eight Logic outputs to send a pulse or a static closing opening to an external device Evac amp Fault contacts Evac and fault output contact reflect the evacuation status and the general fault status of the DIVA system Evacuation inputs Evacuation inputs are contact inputs that allows the monitoring of external contact They also can be used i
146. is valid ex priority ok for a paging then the command register is set to O If not the command register is set to a negative value www ateis europe com Page 225 of 260 STATES TABLE ADDRESS 0x0001 0x0002 0x0003 0x0004 0x0005 0x0006 0x000D Ox000E 0x000F OxO9FB OxO9FC 0x0A03 0x0A04 0x0A05 0x0A0D OxOAOE 0x0A15 0x0A16 0x0A95 0x0A96 0x0B15 0x0B16 0x0B17 0x0B18 0x0B19 Ox0B1A 0x0B1B 0x0B1C 0x0B1D OxOB1E 0x0B25 0x128F 0x1296 0x1297 0x1298 0x1299 0x129A 0x129B 0x129C 0x129D 0x129E 0x129F 0x12A6 0x1715 0x1716 0x171D www ateis europe com DIVA8 SYSTEM REGISTER INTERNAL FAULTS MESSAGE SIZE MESSAGE NAME 1 MESSAGE FAULT 1 MESSAGE LEVEL 1 MESSAGE LEVEL 255 LOGIC INPUT STATES 1 8 _ _ SCHEDULER 128 AMPLIFIERS FAULTS FIREMEN SOURCES LEVEL PSS SOURCES LEVEL MIC LINE SOURCES LEVEL MUSIC 1 SOURCES LEVEL MUSIC 2 SOURCES LEVEL WATCHDOG OUTPUT EVENT TYPE 1 EVENT NAME 1 EVENT TYPE 128 EVENT NAME 128 Page 226 of 260 DIVA8 SYSTEM GLOBAL STATUS 0x0001 name eo GF OoOO 0x0002 Evacuation State GLOBAL STATUS CHANGE 0x0002 Wax Name o oem Gr PSS FAULTS 0x0003 m Wame o ow VP s AUD Microphone ine DC polarzaton aut www ateis europe com Page 227 of 260
147. k box Click the Add to Preparing List button In the message library window you can add and delete messages Clicking the Add button will open a new window see below In this window you can select any wave file to be a message Note Only 16 kHz 16 Bits format will be stored DIVA can handle up to 45 minutes of messages at this format www ateis europe com Page 87 of 260 DIVA8 SYSTEM Look in 29 Message Lib a G Alarm DE 12 Chime 3 notes 9 Evacuation EN 19 Test SP 6 Documents and Settings S tv c Mes documents amp Poste de travail Favorisr seau Filename Files of type Wave File v Cancel By using the Import Export buttons on the Message Library page you are able to import and export complete message library After adding messages from the library to the message manager the procedure to store them into DIVA is as follow tick the messages you want to store and specify whether they are security messages and an evacuation message Click Store to start the store process Once messages are stored into DIVA you can adjust independently their level Follow the next few steps Select a message in the list the name of the message will be displayed in the Current Display indicator Select a zone where you want the message to be played Press the Play button to start playing the message Adjust the level with the arrow keys Press the S
148. l configured go to the Device Search window Tools gt Device Search and start a search If some DIVA master aren t visible please check wiring and or IP address settings Also check your computer network card parameter and be sure they are set in accordance to the DIVA network builded NOTE DIVA master won t be able to communicate with each other through the network This network only intend to offer quick configuration solution over IP www ateis europe com Page 80 of 260 DIVA8 SYSTEM 9 19 Add DIVA8S slave From DIVA software v2 0 0 1 DIVA8S unit can be added in the configuration In order to use slave units follow the next procedure e Inthe Master window click on the Slaves button Master 1 Note Drag Audio sources here a Voice Amp Music Amp e Once click the following window pops up www ateis europe com Speaker Parameters Music 1 Enable Music 2 Enable Mic Line Enable Message Enable Fireman Enable Machine PSS Page 81 of 260 DIVA8 SYSTEM BIIES Add Delete Order display the order of the slave from a DIVA configuration point of view independant from ID setting State indicators that shows the status of the slave unit Only working when real time connected to the master Name displays the name of the slave unit only for configuration purposes The name can be changed to suit your need by
149. le and affordable system solution The system consists of a central rack that contains all equipment including DIVA8M Master unit and 9 pcs of DIVA8S Slave units covering an 80 zones background music and selective paging and voice evacuation system From the central rack a multi pair cable transports the audio to the multiple zones with variable loads The DIVA8M Master unit provides the fireman s operating section on the central paging facility rack and a touch screen multi zone paging and control console This part of the system is also linked to the FACIE The DIVA8M Master unit is linked with the DIVA8S Slave units using a secured link over RJ45 Two powerful 1000 Watt amplifiers provide signals for paging and background music The background music amplifier is also used as back up amplifier in case of an amplifier failure This unique concept guarantees savings on rack assembly and amplifier power The paging console is connected via a secured dedicated link with the central equipment racks A TCP IP link from the main system to the SERVICE area is meant for maintenance use and remote access The paging desk can do all call and zoned call announcements and has a monitor loudspeaker in the unit for system monitoring Central equipment rack 1x DIVA8M for 8 zone paging 9x DIVABS for 9 x 8 zone paging 1x DPAsingle1000 Paging amplifier 1x DPAsingle1000 Music amp Backup amplifier 1x BECS150 Power amp Ba
150. level explanation as well as How To Enter Password 8 1 In Menus The menu display offers the possibility to access different controls and system information Here are the list of menu topic you will be able to access EVACUATION LIST In this menu all evacuation occurrences will be listed from the youngest to the oldest FAULTS LIST In this menu all fault occurrences will be listed from the youngest to the oldest EVENTS LIST In this menu all operation occurrences will be listed from the youngest to the oldest FUNCTIONS MENU In this menu you will be able to manage and set different configuration parameters Note the The front panel buttons are described in the hardware description gt Front View www ateis europe com Page 40 of 260 DIVA8 SYSTEM 8 1 1 Evacuation List In the event of an evacuation state in the DIVA system the Evac Info List will be automatically display as a priority display With the up and down arrow keys you can go through the different evacuation process occurring in the system The youngest evacuation state occurrence is displayed first The evacuation status is displayed as follow 1st line EVAC INFO REPORT 2nd line XXXXXXXX Note the XXXXXX depends on the name of the evacuation event used 8 1 2 Faults List In the event of a fault state in the DIVA system the Fail Info List will be automatically displayed With the up and down arrow keys you can go through
151. lready an higher priority event active in at least on zone of the event The lower priority event won t be able to start in cancel all mode and can be started in non common zone in coexist mode In order to make it clearer here is an example Event 1 play message priority 4 busy relay CH1 Event 2 play message priority 1 When Event 2 is active the output relay CH1 is active It informs that an higher priority event is active and that Event 1 wont be played or partially be played if it is activated The Busy relay can be set in all event setting window follow the next steps to activate and set an Busy relay CENE ACK Relay gt Busy Relay T2 T8 Master Tick the check box in order to enable the busy relay option e Select on each device master and or slaves the output channel that will be used as busy relay contact Note multiple output channel can be selected for an event 9 33 3 Active at Start Relays The Active at Start relay named start impulse will allow the activation of an output channel when an event is started The start impulse relay can be set in all event setting window follow the next steps to activate and set an start impulse Start Impulse Stop Impulse Enable i 1 2 s s e r Master Tick the check box in order to enable the start impulse option Choose between the pulse mode or static mode Pulse mode will generate a contact pulse for the ti
152. m Select None ui Delete Select None Memory Used _ The message window is divided in two sections one for the message taken from the message library left one and one for the messages stored in DIVA right one Here is a list of buttons and their corresponding function Select All allows to instantaneously select all the messages from the list Select None instantaneously deselect all the selected message MSG Library will open the message manager Store Stores permanently the selected messages into DIVA s memory Delete deletes selected messages from the store list Read reads messages stored into DIVA unit Delete deletes messages from DIVA memory Select All allows to instantaneously select all the messages from the list Select None instantaneously deselect all the selected message To add messages to DIVA you need to access the message manager Library by clicking on MSG Manager The Message Library window will pops up see below www ateis europe com Page 86 of 260 DIVA8 SYSTEM F Message Library C Program Files ATEISSDIVA v2 0 0 1 T Message Lib Browse Export Message Name Format Size Sample Rate WAV Chime 3 notes WAV way 1 Alarm Evacuation EN wav est SP way 16kHz 15kHz 18kHz 1kHz 63 37kB 177 23kB 239 95kB 21214 Select All la Add to preparing list Delete Select the message by ticking the chec
153. me can be understood like the amount of time that the signal have to be over the threshold point before music source will be activated A correct setting of the attack time can avoid inopportune activation of the music source peak signal activation The Attack time can be set from 0 ms to 5000 ms e Release Time ms As opposed to the Attack time the Release time is the amount of time for which the signal have to stay under the threshold point before deactivation of the music sources A correct Release Time can avoid inopportune deactivation of the music source blank in CD The release time can be set from 0 ms to 5000 ms Setting those parameter correctly needs some experience so be careful and please test it to learn more about the behaviour of this option Once your modulation detection parameters are adjusted you have to edit the advance setting for the music sources please refer to the Use Music Source general chapter 9 26 3 In Permanent Mode In Permanent mode the music sources are set once and cannot be manage anymore from front panel However real time controls are still useable To change the sources routing you will have to change the DIVA configuration In permanent mode you only have to Edit the music sources parameters Note be carful when setting priority for both music sources Same priority for the two music sources can result in conflict 9 26 4 From PSS The PSS microphone is able to operate on music sourc
154. me message before each call You can choose the chime message using the drop down menu Pre define Zone by ticking this option you will be able to select pre define zone in which the call will be made Pre defining zones don t disable the front panel zones selector As soon as a call in non pre defined zone is finished the next call will be automatically rerouted in the pre defined zone after the amount of time set in the fireman microphone main window By clicking Ok you will validate your settings Cancel will annulled the current settings 9 26 Use Music Source In order to use music sources first drag and drop music source from the Design Component Section to the Master window Double click the music source Icon to enter the Music Source window see below Music sources routing can be managed from front panel from PSS and from logic input You can also use real time control and indicators in order to adjust the music sources level to mute sources independently and to check music sources status See the following chapter to learn more Use Music Source From Front Panel With Modulation Detection In permanent Mode Use Music Source From PSS Use Music Source From Logic Input Software Control The use of music sources in combination with Vox Net is discussed in the How to Put DIVA in Vox Net chapter please refer to it for more information www ateis europe com Page 118 of 260 DIVA8 SYSTEM Music
155. me set range from 50ms to 60000ms Static mode will activate the output contact for the entire duration of the event Select on each device master and or slaves the output channel that will be used as Start Impulse contact Note multiple output channels can be selected for an event 9 33 4 Active at Stop Relays The Active at Stop relay named Stop Impulse will allow to activate an output channel when an event is stopped www ateis europe com Page 154 of 260 DIVA8 SYSTEM The stop impulse relay can be set in all event setting window follow the next steps to activate and set an Active at Stop relay Enable Length po m n Start Impulse Stop Impulse Logic Output Channel Device EE EAE LJ jl Master Tick the check box in order to enable the relay Set the contact pulse length range 50ms to 6000ms Select on each device master and or slaves the output channel that will be used as Start Impulse contact Note multiple output channels can be selected for an event 9 33 5 Use Bypass Relay The bypass relays are independent of events The goal of bypass relay is to close open a relay when some zone s are occupied with a type of source In order to set a bypass relay follow the next few steps e Goin menu View gt GPIO gt Bypass Relay tab GPIO Normal Logic puts Evacuation puts Exte Channel 1 Normally Open
156. mple L25 means clear zones grouped on code 5 if they are occupied by channel 2 L41 3 means clear zones grouped on codes 1 and 3 occupied by channel 4 The answer is the same as previous clear command Normal level for all the channels command string NOOO The normal level value is setup inside the slave configuration answer is always ACK CR Loud level for all the channels commandstring S000 The loud level value is setup inside the slave configuration answer is always ACK CR www ateis europe com Page 223 of 260 DIVA8 SYSTEM Reduced level for all the channels commandstring A000 The reduced level value is setup inside the slave configuration answer is always ACK CR Date and time setting command string Hddmmyyhhmmss where dd is day mm is month yy is year hh hour mm minutes ss seconds Status Fault request command string E Answer is the string Eedusdus where e is the global state of the slave space for no fault D for deferred fault I for immediate fault du is a code number dozens and units always 2 digits and s is the status of this code a character with this binary format 0010LBID where L is set if the code is occupied by a local source of the slave B is set if the code is occupied by the modan source is set if at least one zone of the code is in immediate fault and D is set if at least one zone of the code is in deferred fault The codes are the ones which are setup in the slave configu
157. mpressor threshold range with the lower yellow cursor Comp Limiter 20 30 40 50 60 50 40 30 20 10 0 10 20 30 40 www ateis europe com Page 185 of 260 DIVA8 SYSTEM 9 40 Use Presets The DIVA application allows user to create different preset that can control audio settings audio levels on each source hi pass and low pass filter settings compressor limiter settings Loading a preset will change the current audio settings you can adjust audio settings for different situation using several presets In order to create a preset please follow the next few steps e To create a new preset click on the Add button in the preset toolbar i Preset e By default the preset created is named untitled X You can rename it by clicking on the Name button in the preset toolbar Preset Untitled zlim ja 4 di Rename Sel No 1 Untitled e To relate a setting to a preset right click on the control and link it to a created preset in the list The value set when linking a control to a preset will be saved to the preset www ateis europe com Page 186 of 260 DIVA8 SYSTEM To modify a setting in the preset load the preset change the value and then save the preset with the save button in the preset toolbar Presets can be loaded using the load preset event To learn more about the load preset event please read this Note a con
158. music sources are used keep in mind that attenuator will only have effect on only one of them music 1 Because the Voice amplifier will be used for music 2 the attenuators won t have any effect on the sound level Note Music attenuator are only available on Master DIVA unit 9 26 2 With Modulation Detection The modulation detection mode allows to automatically route music sources in case of signal presence You can set up both source one and two in modulation detection as well as only one source The normal use of this option is to set up one source in permanent mode and the other one in modulation detection example tuner in permanent and CD player in mod det Keep in mind that in that mode the music front panel buttons are disabled Modulation Detection Modulation Detection Threshold dB 1 Attack Time ms ur dug F aj du Release Time ms ea ea PE In order to use the modulation detection tick the Modulation Detection option for the source you want to use that way Once the option selected you will have access to detection settings Threshold dB The threshold setting will set the trigger point for activation of the music source If the threshold is set to 10 dB the music source activation will take place when the signal received from that source will be over 10 dB Attack Time ms www ateis europe com Page 121 of 260 DIVA8 SYSTEM The Attack ti
159. mware version If one unit is in a uncompatible version the version number will be red highlighted In that case an update has to be done www ateis europe com Page 70 of 260 DIVA8 SYSTEM 9 13 Update The update command allow user to upgrade the DIVA internal software to the version delivered with the Windows based software This is one of the first things to do when starting a new project or using a DIVA unit for the first time This could really save time and avoid communication and store problem To activate this command go the menu Tools gt Update The Update window will pop up Slave Update PSS Update PSM Update Ethernet PSS Update File Path Program Files ATEISSDIVA y2 0 0 25mcu_update CRC 42739 Update Close On this window you will find 4 different tab which correspond to 4 different update process UPDATE allows the update of the DIVA master unit Slave update allows the update of all slave units in the system PSS Update allows the update of the PSS console PSS Update allows the update of the PSM CD16 microphone consoles Ethernet PSS Update allows the update of all the Ethernet PSS found in the network To perform update you need to have the user level 4 rights Once clicked on the update button you will be prompt to enter an username and password if not already logged in www ateis europe com Page 71 of 260 DIVA8 SYSTEM 9 13 1 Update Master Unit
160. n UGA mode trigger by a voltage polarization change This connector supplies a 24VDC source 100V Signal links 100V output to send 100V signal to others DIVA M or S unit Amplifiers I O Voice Amp connector include the OdB channel to power amplifier and the 100V audio channel from power amplifier Same for Music Amp Music amplifier channel will be used in case of defect on the Voice amplifier channel as a backup amplifier channel RS232 Connector SUBD 9 connector that includes two RS232 ports Ethernet Connector RJ 45 Connector to link the DIVA master to the ethernet network for software configuration and or to enable IP paging Speaker zone outputs Eight speaker zone connectors splitted in A and B line PSS PSM connector RJ 45 connector to link PSS or PSM call stations Master Slave link RJ 45 connector to create a master slave DIVA system Remote Ext connector www ateis europe com Page 16 of 260 DIVA8 SYSTEM not used Mic line input XLR connector to plug a microphone or a third line level audio source Music inputs Cinch connectors to plug two different OdB audio sources External fireman mic input A replica of the front Fireman Microphone connector Backup power input 24VDC power supply for battery operation 3 5 DIVA8S Front View Power Indicator VACIE LED Indicators Zones Selection Buttons Power indicator LED Indicates the power status of the DIVA Vacie indicators The
161. n overall view of busy zones and active sources A VU meter controls the microphone presence and modulation level A built in loudspeaker makes it possible to listen to all system generated messages and announcements The PSSDT console is SINAPS security system interface and is fully monitored microphone capsule power supply touchscreen audio and RS485 connections Any system faults are detected located and indicated clearly on the screen Different product references are available to suit all site sizes PSS849 4 zones for SINAPS Compact IDA4 PSS12DT 12 zones for SINAPS M SINAPS XM and DIVA8M PSS24DT 24 zones for SINAPS M SINAPS XM and DIVA8M www ateis europe com Page 19 of 260 DIVA8 SYSTEM PSS48DT 48 zones for SINAPS M SINAPS XM and DIVA8M PSS72DT 72 zones for SINAPS M SINAPS XM and DIVA8M PSS96DT 96 zones for SINAPS M SINAPS XM and DIVA8M 4 3 PSM Unidirectional Condenser Addressable Microphone compatible with IDA8C IDA8S IDA4 series and DIVA devices via RS485 protocol over a single CAT5 cable connection to transport both Audio and Power to the PSMxx from the IDAxx DIVA system The unit comprises of 8 zones 8 buttons with sleek condenser gooseneck microphone and spring metal protection providing durability and excellent aesthetics as well as allowing up to 256 zones expansion via the additional Keypad easy extension station The buttons can represent a single zone or a group of zones and are ea
162. n the Graphic button you will enter the filter graphic edition window see below By moving the blue point you can adjust the cutoff frequency www ateis europe com Page 172 of 260 DIVA8 SYSTEM 16 31 5 63 125 250 500 1K 2K 4K 8K 16K 31 5K 9 37 2 On Outputs e To add high or low pass filter on audio amplifier outputs double click on the icon PEQ Voice Channel or PEQ Music Channel in the DSP Configuration Window The following window pops up Note more explanation about amplifier output PEQ can be found here e follwing window will pop up Volume Level 98 Overflow e Clicking on the EQ square will call for the amplifier equalization page www ateis europe com Page 173 of 260 PEQ N A DIVA8 SYSTEM The first PEQ filter can be changed to a High pass filter with the corresponding drop down menu see below The last PEQ filter can be changed to a Low Pass filter with the corresponding drop down menu see below AMP PEQ N A Oven Sed For the low pass and high pass filter you have access to the following settings cutoff frequency and gain By clicking on the Graphic button you will able to adjust the cutoff frequency and the gain directly by moving the corresponding yellow cursor see below www ateis europe com Page 174 of 260 F Voice Amp DIVA8 SYSTEM 30 10 125 16 20 25 31 5 40 50 63 80 100 125 160 200 250
163. n the compressor limiter icon the compressor limiter window pops up see below Adjust the Compressor Limiter parameters to suit your needs www ateis europe com Page 182 of 260 DIVA8 SYSTEM Comp Limiter MIC Line Type here you can choose between the compressor component or the limiter o Bypass clicking on the bypass button will instantaneously bypass the compressor limiter Soft Knee if the soft knee button is pressed the a soft knee will be applied to the compressor limiter instead of a hard knee o Compressing in case of compressor this will indicates if the compression is acting or not o Limiting in case of limiter this will indicates if the limiter is acting or not o Ratio Comp x 1 here you can specify the compression ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as limiter o Ratio Limiter x 1 here you can specify the limiter ratio either by using the slide bar arrow key or by entering directly the value in the dedicated cell Note this parameter will have no action if the filter type is set as compressor Threshold dB here you can specify the threshold level from where the limiter or compressor will start acting Threshold range dB here you can specify the range of level in which the ratio gradually alters from 1 1 to the value set by the ratio
164. nd or to enable busy relay or acknowledgement relay Referring to the picture below the upper squares are for output relay activation and the lower squares for acknowledgement and busy relay states Start Impulse Stop Impulse Enable 2 3 415 6 7 8 Master ACK Relay Busy Relay Enable ou LLL ouar T4 ES TS T7 eo Master Note DIVA Master and Slave offer 8 output relay each Keep in mind that one relay can only rely to one action Multiple activation of output relay is not possible 9 33 1 Acknowledge Relay The purpose of the Acknowledge relay is to indicate to persons that the event is active Trying to call in a zone where a higher priority event is active will result in a refusal of that call in this zone The acknowledge relays will keep you aware of that by being not active The acknowledge relay can be set in all event setting window follow the next steps to activate and set an acknowledge relay ACK Relay Busy Relay RR d Enable DS T4 T5 ES T7 T7 Master Tick the check box in order to enable the acknowledge relay option e Select on each device master and or slaves the output channel that will be used as acknowledge relay contact Note multiple output channel can be selected for an event www ateis europe com Page 153 of 260 DIVA8 SYSTEM 9 33 2 Busy Relays The busy relays have been made to inform user that there is a
165. ne A Open Slave 01 Zone Line A Open 501 2 1 A OPEN Slave 01 Zone 1 Line A Open SO1 Z 8 A OPEN Slave 01 Zone 8 Line A Open Slave 15 Zone Line A Open S15 Z 1 A OPEN Slave 15 Zone 1 Line A Open S15 Z 8 A OPEN Slave 15 Zone 8 Line A Open Zone Line A Short Master Zone Line A Short MO1 Z 1 A SHORT Master Zone 1 Line A Short MO1 Z 8 A SHORT Master Zone 8 Line A Short Slave 01 Zone Line A Short 501 2 1 A SHORT Slave 01 Zone 1 Line A Short 501 2 8 A SHORT Slave 01 Zone 8 Line A Short Slave 15 Zone Line A Short S15 Z 1A SHORT Slave 15 Zone 1 Line A Short 15 Z 8 A SHORT Slave 15 Zone 8 Line A Short Zone Line B Impedance Master Zone Line B Impedance 1 2 1 B IMPEDE Master Zone 1 Line B Impedance MO1 2 8 IMPEDE Master Zone 8 Line B Impedance Slave 01 Zone Line B Impedance 501 2 1 B IMPEDE Slave 01 Zone 1 Line B Impedance 501 2 8 IMPEDE Slave 01 Zone 8 Line Impedance Slave 15 Zone Line B Impedance S15 2 1 IMPEDE Slave 15 Zone 1 Line B Impedance 515 Z 8 B IMPEDE Slave 15 Zone 8 Line B Impedance Zone Line B Open Master Zone Line B Open MO1 2 1 B OPEN Master Zone 1 Line B Open MO1 Z 8 B OPEN Master Zone 8 Line B Open Slave 01 Zone Line B Open 501 Z 1 B OPEN Slave 01 Zone 1 Line B Open S01 Z 8 B OPEN Slave 01 Zone 8 Line B Open Slave 15 Zone Line B Open 515 Z 1 B OPEN Slave 15 Zone 1 Line B Open S15 7 8 B OPEN Slave 15 Zone 8 Line Open
166. nect to a known master DIVA IP without doing the search process Close closes the Device Search window Before starting to search for devices connected to an IP network search group have to be defined Please follow the next few steps Click on the Edit Search Group button the search group window appears www ateis europe com Page 56 of 260 DIVA8 SYSTEM Search Group Click on the Add button the Edit Search Group window appears Edit Search Group SEE Name Group Stat dlc MEM Cancel Enter a name for the group Enter an IP addresses range enter the start address and the end address e Click OK In the Search Group window you can manage groups by deleting them or edit them To delete or edit one group tick the corresponding check box and click on either the Delete button or the Edit button e Click on the Search button to start the search process Click on the corresponding device line e Click on the Auto Connect button A window pop up indicates the connection status You can also manually enter the DIVA IP address by click on the Manual Connect button This avoids using the search process if the IP address of the device is known To search the network for Ethernet PSS devices go on the Ethernet PSS tab www ateis europe com Page 57 of 260 DIVA8 SYSTEM Device Search Edit Search Group DIVA Machines Ethemet PSSs OOP Adress Group IP lt No d
167. network settings follow the next steps this step by step procedure is only accurate for Windows XP From Start go to Settings then Control Panel From the Control Panel double click Network Connections icon e If you have created a Local Area Connection and want to modify it right click the icon highlight Properties Note choose the Network connection card you ll use Local Area Connection Properties PR General Authentication Advanced Connect using 3Com 3 920 Integrated Fast Ethernet Controller 3C905C R This connection uses the following items vi El Client for Microsoft Networks O File and Printer Sharing for Microsoft Networks vi QoS Packet Scheduler Description Transmission Control Protocol Intemet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected DK Cancel Highlight Internet Protocol TCP IP and then click on properties It will display the following Internet Protocol TCP IP Properties dialog box www ateis europe com Page 53 of 260 DIVA8 SYSTEM Internet Protocol TCP IP Properties General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use
168. ng events Music 1 On Unmutes the music sources one Music 1 Off Mutes the music sources one Music 2 On Unmutes the music sources two Music 2 Off Mutes the music sources two 6 4 Tab Bar Opening design or component control windows creates a new tab within the tab bar The active window is orange highlighted and can be closed by clicking the close box at the right side of the bar System Master 1 As the tab bar gets full additional orange colored arrow control boxes will appear at the right side of the tab bar Click on the left or right arrow to move the content of the tab bar to the left or the right 6 5 Design Component Section The Design Component Section shows in a tree folder arrangement all element that can be connected or added in a DIVA configuration All the component are drag and drop component errors are avoid thanks to the emplacement identification See How to Add Design Component www ateis europe com Page 35 of 260 DIVA8 SYSTEM DIVA System Master Audio Source Fireman Microphone e PSS 9 Music Microphone yy Line In Audio Component Filter gt HijLo Pass hh PEQ Compressor Limiter Compressor Limiter Compressor Limiter DIVA System In the DIVA System folder you will find DIVA Master unit icon See How to Add Design Component e Audio source In Audio Source folder you will find audio elements that can be connected to a master DIVA unit
169. nge the unit Leakage impedance between slave XX amplifiers pins and ground drops under threshold Action Check the master voice and music amplifiers status power fault LEDs and condition Check amplifiers wiring condition If necessary exchange the unit Master zone X line A impedance is out of tolerance Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line A impedance is out of tolerance Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Master zone X line A impedance is higher than 5kOms The corresponding speaker line is seen as OPEN Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the line Reset monitoring Slave XX zone Y line A impedance is higher than 5kOms The corresponding speaker line is seen as OPEN Action Check the corresponding impedance real time measurement in the software monitoring window Check the line speakers condition Change the line wiring or speaker Take new references for the l
170. nitoring used a pilot tone at 18kHz or 20kHz that is adapted to pull out 2 Vrms By measuring the output signal of the amplifier and computing it in the DSP we can adjust the level of the pilot tone The adjustment of the pilot tone is related to the amplifier gain and can directly inform us on the gain value The gain variation are measured constantly and compared to a gain references value Below you can find a bloc schematics for Voice amplifier channel VOICE PRE AMPLIFIER PILOT TONE GENERATOR VOLTAGE TRANSFORMER MEASUREMENT UNIT NOTE If the amplifier gain is changed after the reference has been taken the pilot tone level could increase dramatically Example the reference is taken with a gain of 1 the pilot tone will be set to 2Vrms Then if the amplifier gain is increased to 100 the pilot tone level will be raised to 200Vrms To avoid problems the gain of both Music and Voice amplifier should be set to same value and in preference to the maximum gain value There is three different channel for monitoring Voice amplifier channel Music amplifier channel and VO3 channel VO3 is channel that only generate the pilot tone in case no amplifier channel is in used Zone Monitoring Zone Monitoring is based on three different reference values Line A Line B and Line A B Reference for Line A and Line B are Line A and Line B direct impedance measure Reference Line A B correspond to the Line A and B in parallel Line A Za
171. nnections to the DIVA and make sure to use adequate cables Do not use benzene thinner or chemicals to clean the DIVA Use only a soft dry cloth If the DIVA is moved from a cold place e g overnight in a car to a warmer environment condensation may form inside the unit which may affect performance Allow the DIVA to acclimatize for about one hour before use www ateis europe com Page 259 of 260 17 DIVA8 SYSTEM International sales and service points B8 0 LE ATEIS Europe B V Sydneystraat 42 3047 BP ROTTERDAM NETHERLANDS Phone 31 0 10 2088690 Fax 31 0 10 2088699 www ateis europe com info ateis europe com ATEIS France SAS 32 av de l europe ZA de Font Ratel 38640 Claix FRANCE Phone 33 0 4 76 99 26 30 Fax 33 0 4 76 99 26 31 Sales 33 0 4 76 99 26 37 www ateis france fr contact ateis france fr ATE S Germany GmbH Kirchenstrasse 11 82194 Gr benzell DEUTSCHLAND Phone 49 0 8142 305070 30 Fax 49 0 8142 305070 39 www ateis germany de info ateis germany de UK Ltd 102 Victoria St St Albans Hertfordshire AL1 3TG UK Phone 0845 652 1511 Fax 0845 652 2527 www ateis co uk infoplease ateis co uk ATEIS Suisse SA Chemin du D vent 1024 Ecublens SWITZERLAND Phone 41 0 21 881 25 10 Fax 41 0 21 881 25 09 www ateis ch info ateis ch www ateis europe com Penton ATEIS USA 21 Sabin St Pawt
172. nputs l External Fault Inputs Name Nemaly Close Open Latch Mode Monitor Event Setting Channel 1 Normally Open Channel 2 Normally Open Channel 3 Normally Open Channel 4 Normally Open Monitor Mode Channel 5 Normally Open Channel 6 Normally Open Channel 7 Normally Open Channel 8 Normally Open Channel 9 Normally Open DIVA Machine Master 1 e Name Here you can specify a name by simply clicking in the box Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact is open in neutral www ateis europe com Page 151 of 260 DIVA8 SYSTEM position e Latch Mode By ticking this option you will set the contact to be in latch mode It means that you will need on trigger to open close the contact and one more trigger to get it back to the neutral position v e Monitor By ticking this option in contact or UGA monitoring mode you will define an input as a monitored logical input Event Setting By clicking start you will be able to associate an event to this input Monitor Mode With the drop down menu you can choose between contact monitoring mode or UGA mode Contact monitor mode implies the use of an resistor network on a contact see How To Create a Monitorable Button The UGA mode is based on polarizing the input with an external 24VDC source provided by external devices N
173. nt panel you have the possibility to assigned music sources to a zone or multiple set up attenuation for each speaker zone only on music To manage music source the music sources should be set in Route Key mode see How To Use Music Source The procedure to assign a music source to a zone is the following Select the music source O Press the SELECT button to go from Source 1 to Source 2 O Press SELECT button to go from Source 2 to no selection o Press SELECT button to re select Source 1 Select the zone s O Press the zone button s you want to activate on Master and or Slaves The corresponding white selection LED s should light s up Validate the routing by pressing the ROUTE button Zone attenuators In each master zone the music level can be attenuated depending your needs The attenuators offer 6 attenuation positions 0 4 8 12 16 20 dB Agjust the corresponding zone s ATTENUATOR KNOBS to the desired attenuation level Note zones that are monitored cannot be attenuated to 20dB without causing monitoring problems At 20dB attenuation the accuracy of the impedance circuitry reach its limit Note if two music sources are used keep in mind that attenuator will only have effect on only one of them music 1 Because the Voice amplifier will be used for music 2 the attenuators won t have any effect on the sound level Note Music attenuator are only available on Master DIVA unit 8 3 Messages an
174. o Use Logic Inputs The idea is to use logical trigger to start an event Event type for operation on Mic Line are listed below You can find more information on those events in the chapter How To Use Events Mic Line Paging Event In order to associate a event to a logic input trigger click on the Start button under Event Setting The Events Selection window will be open see below www ateis europe com Page 146 of 260 DIVA8 SYSTEM Events Selection Name Priority Type Security Name Type Security Delete Select None Shit Down Cancel Event Select All Select All Shift U Insert New Edit Delete t Select None elect None On the left side you will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type see below New Event Master Select Master 1 Event Type Music On In order to select the event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the event created with t
175. on protocols chapter The serial port pinning information can be found in the How to Wire Devices chapter www ateis europe com Page 191 of 260 DIVA8 SYSTEM 9 43 3 For Vox net Modan In this chapter we will see how to set the RS232 port of DIVA to communicate with a Vox net server client or a remote access modan protocol configuration e To access the RS232 port settings click on the RS 232 Port1 or RS 232 Port2 tabs As the settings are the same for both ports only one will be introduced Master 1 Note Drag Audio sources here 5 232 Portl RS 232 Port2 Voice Amp Baud Rate 38400 Front Panel Setup Data Bits Parity No Parity StopBit Music Amp Ethernet PSSs Protocol None Procedure e RS 232 Port 1 choose the Vox Net protocol wit the protocol drop down menu Select the 9600 as Baud Rate Data bit should be set to 8 Stop bit should be set to 1 Parity should be set to Even Parity More information about the Vox net protocol and how to use it with DIVA can be found in the communication protocols chapter The serial port pinning information can be found in the How to Wire devices chapter www ateis europe com Page 192 of 260 DIVA8 SYSTEM 9 44 Put DIVA in Vox net The DIVA system can be used as a matrix in any Vox Net system It can also be used in a remote access configuration using RS 232 DI
176. ontact your Ateis dealer Front panel MSG TEST key contact line is defective the contact line is seen as an open line no contact Action Please contact your Ateis dealer Front panel MSG TEST key contact line is defective the contact line is seen as an shorten line short circuit on contact Action Please contact your Ateis dealer Page 252 of 260 ALL CALL OPEN ALL CALL SHORT PSSG2 faults PSS DISCONNECT PSS SPK FAIL PSS MIC FAIL PSS TFT FAIL PSS AUDIO FAIL PSSG2 E faults EPSSX DISCONNECT EPSSX SPK FAIL EPSSX MIC FAIL EPSSX TFT FAIL www ateis europe com DIVA8 SYSTEM 1 8 1 8 1 8 1 8 Front panel ALL CALL key contact line is defective the contact line is seen as an open line no contact Action Please contact your Ateis dealer Front panel ALL CALL key contact line is defective the contact line is seen as an shorten line short circuit on contact Action Please contact your Ateis dealer Communication between DIVA master and PSSG microphone console has been lost Action Check PSSG2 condition Check the PSSG2 DIVA wiring path Check PSSG2 power supply If necessary exchange the PSSG2 unit Embedded PSSG2 monitoring speaker is defective Action Check PSSG2 condition Check the PSSG2 DIVA wiring path If necessary exchange the PSSG2 unit PSSG2 microphone is Action Check PSSG2 condition Check the PSSG2 DIVA wiring path If necessary exch
177. order to access and activate zones monitoring and or amplifiers monitoring click on the monitoring button under DIVA icon in the master window see below Master 1 Note Drag Audio sources here Voice Amp Music Amp The monitoring window is then opened see below www ateis europe com Speaker Parameters Machine PSS Music 1 Enable al Music 2 Enable is Mic Line Enable Message Enable Fireman Enable Page 161 of 260 DIVA8 SYSTEM F Monitoring Norma Tone Generator Monitoring period Detect Settin Active Mode Periodic Bypass Relay Action Type Normal Open Active Monitor Period 00 01 30 Detect Contro Hw Observer Mode Enabled Current Monitor Target 0 Warning After test is done to make sure that the mode is disabled Monitor Device Master 1 Leakage Impedance Threshold ohm 5000000 7 Leakage Impedance Measure ohm Zone Monitoring YoiceAmp Music Amp Referenced Ohm ReferenceB Dhm ReferenceA B Ohm Connected Source Tolerance 2 Measure Ohm Diff 2 15 0 15 15 15 15 15 15 15 on 4 Co n2 gt Y Y Y Ys 4b 4b 4b 4b 4b 4b 4b 4 General options Normal Tone Generator access the tone generator window please see how to use the tone generator Monitoring Period if front knob attenuators are in use and if the attenuation value is 16 or 20 dB the monitoring for acc
178. osing will switch off music in pre www ateis europe com Page 109 of 260 DIVA8 SYSTEM defined zone s Toggle Music By Zones Event Type Toggle Music On Off By Priority 20 lt ero equals highest Name Event 14 Attrib Security Next Event None Active at Start Active at Stop Logic Output Logic Output Channel Channel Length Length Music Source Music 1 Master 1 1 2 3 4 5 6 7 8 All Cancel Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay Music Source here you can choose the music source you want to
179. ote The UGA mode is an alternative way of using contact It does not offer real monitoring behaviour and does not increase security 9 32 3 External Fault Inputs As explained before the External fault Inputs have been implemented in order to offer the possibility to force DIVA to enter his security mode For more information about security mode please read this The external trigger of those inputs should come from security devices such as security power supply You can also use those input to force DIVA into the security mode in order to save energy during night Like any of the logic inputs you can associate an event to External Fault Inputs Logic Inputs mE Normal Logic Inputs Evacuation Inputs External Fault Inputs Normall Close Open Event Setting Channel 1 Normally Open Start Channel 2 Normally Open Start DIVA Machine Master 1 Name Here you can specify a name by simply clicking in the box Normally Close Open Here you can specify the behaviour of the inputs Normally closed means that the contact is closed in neutral position and reciprocally normally open means that the contact is open in neutral position e Event Setting By clicking start you will be able to associate an event to this input www ateis europe com Page 152 of 260 DIVA8 SYSTEM 9 33 Use Output Relay In some event windows of DIVA software you will have the possibility to set an action for output relay a
180. ound on the Ateis Europe website 9 29 1 General Page Here is a list of parameters that can be adjusted in the General tab Properties Section Name here you can set a name for your PSM Priority here you can set the PSM priority Take care when choosing a priority as the PSM could be a security microphone as well as a evacuation source www ateis europe com Page 138 of 260 DIVA8 SYSTEM Mic Level Overflow Mic Gain Priority Zero equals highest 98 Speaker Overflow 1 No Fault Report on PSM TE Speaker L No Fault if PSM Missing Gain 1 Press To Talk Post None 98 Clip Security Source Threshold dB Volume dB Evacuation Source 2 PRE AMP 2 SPK Cable MIC gt MIC Out LCD 2 Keyboard _ MIC Cable 2 Missing Mode e No Fault Report on PSM if ticked no DIVA fault status will be shown on the PSM fault LED No Fault If Missing if ticked DIVA won t display a fault if the PSM is not physically connected Press To Talk this option change the behaviour of the Mic key on the PSM screen from Lock to Talk to Push to Talk For calling in Push to Talk mode you have to keep the PSM Mic key press as long as you want to talk Security source Evacuation source if ticked you will be able to use the PSM microphone when DIVA has entered into the security mode When ticked it adds the option Evacuation Source If evacuation source is selected the paging from the PSM
181. places www ateis europe com Page 10 of 260 DIVA8 SYSTEM 2 1 Application Example 1 High rise building with distributed sound for multi zone paging 0 Ethernet 8 groups x 5W 80 groups vertical cabling back bone Toilet Office 1 2 Meeting room 10 groups x 5W Dealing T aad T 7 Room2 Office 1 Office 2 Dealing Room 1 i 10 groups x 10W Maintenance Desk Office 1 and service ue Toilet Meeting 5 groups 20W room rum Room 1 ROO 2 DIVA8M Desk 10 groups x 10W Front Desk Office 1 Office 2 DIVA8S Waiting Office 1 5 groups 20W Room GE Office 2 219 Divass DRE cont 10 groups x 10W I DIVA8S Room 1 Lour d oom Meeting E Tolet Office 2 d DNAES 5 groups 20W room E Office 3 DIVA8S Office 1 a DIVA8S a Em 10 groups x 10W EM I Toilet mes mew Divass 5 groups x 20W Office 1 Lodo bm Front DIVA8S Desk poma T EDEN LL CLE IL iia J DIVABS Rest Toilet 1 group x 100W Kitchen DPA single 1000 1000W DPA single 1000 1000W TE rex BECS 240 1000 bs High rise buildings with distributed sound for multi zoning paging This tutorial describes a PAVA system VACIE which is used for voice evacuation with an automatic link to a fire panel system FACIE for high rise building applications with multizone paging requirements The DIVA concept represents a reliab
182. ple below shows code 1 zone 1 code zone 2 and code 3 all zone www ateis europe com Page 196 of 260 DIVA8 SYSTEM F Vox Net Editing Port1 2 Point to point Mode Point to point Channel 1 Music 1 Note Each audio source Channel 1 None Note Each audio source can be only controled by can be only controled by Channel 2 Music 2 one channel Channel 2 None one channel Channel 3 None Channel 3 None Master 1 Zone 1 v Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 oe 2 515 2 5 7 4 e Compile and Store config At that point DIVA will route Music 1 or Music 2 according to the code received If the master sends Channel 2 code 2 DIVA will route Music 2 input to zone 2 Channel 1 or channel 2 will be used depending on remote access master channel selection Multipoint DIVA s audio input will be used in the same way for point to point mode or in multipoint mode so the following steps only concern the Vox net editing window e Go into the menu View gt Vox Net Editing the following window should pop up www ateis europe com Page 197 of 260 DIVA8 SYSTEM VoxaNet Editing Porti Port2 Mode Multipoint Addr Y Mode Point to point Channel 1 Music 1 w Note Each audio source Channel 1 None Note Each audio source can be only controled by can be only controled by Channel 2
183. port on PSS Message 1 dB L No Fault if PSS Missing None 1 Press To Talk Message2 Mic Level Overflow Security Source None v Evacuation Source Speaker Message 3 Overflow Option Buzzer ON 1 External Microphone Double Click None Message 4 None Chime Selectio Delays Zero is no time out Pre None Standby 0 Post None Lock 0 Volume dB 2 PRE AMP SPK Cable gt MIC MIC Out LCD 32 Keyboard MIC Cable 2 Missing Mode No Fault Report on PSS if ticked the PSS won t display faults of the DIVA system No Fault If Missing if ticked DIVA won t display a fault if the PSS is not physically connected Press To Talk this option change the behaviour of the Mic key on the PSS screen from Lock to Talk to Push to Talk For calling in Push to Talk mode you have to keep the PSS Mic key press as long as you want to talk Security source Evacuation source if ticked you will be able to use the PSS microphone when DIVA has entered the security mode When ticked it adds the option Evacuation Source If evacuation source is selected the paging from the PSS will act like an evacuation event So the front panel EVAC LED will light up Options Buzzer On this options allows user to enable the PSS buzzer It will beep for any DIVA fault status and for PSS internal fault External Microphone in case of using an other microphone that the gooseneck you will have to tick this option Double Cl
184. pter www ateis europe com Page 23 of 260 DIVA8 SYSTEM 5 Software Installation As briefly mentioned in the Installation paragraph DIVA8M package hold a CD Rom The CD contain the DIVA8M Quick Start Manual pdf User Manual Microsoft HTML Help Executable chm HTML htm and DIVA software It could happen that the software on the CD Rom is not the last release In that case please visit ATEIS website to download the latest release and follow the steps described in the Software_Installation Process 5 1 Installation Process Insert the CD Rom in your computer Double Click on the My Computer on the desktop Open the CD ROM submenu Double Click on the DIVA software icon ENATEIS DIVA v1 0 0 The DIVA installshield wizard will prompt Please follow the install instruction that are displayed i ATEIS DIVA v1 0 1 21 InstallShield Wizard Welcome to the InstallShield Wizard for ATEIS DIVA v1 0 1 21 The InstallShield R Wizard will install ATEIS DIVA v1 0 1 21 on your computer To continue click Next WARNING This program is protected by copyright law and international treaties Change the User Name and the Organization s name at your convenience www ateis europe com Page 24 of 260 DIVA8 SYSTEM i ATEIS DIVA v1 0 1 21 InstallShield Wizard Customer Information Please enter your information User Name Ateis International Organization Install this
185. r Ateis dealer Audio line management chip doesn t answer Action please contact your Ateis dealer Master leakage management chip doesn t answer Action please contact your Ateis dealer Slave XX leakage management chip doesn t answer Action please contact your Ateis dealer Function LEDs management chip doesn t answer Action please contact your Ateis dealer Master zone LEDs management chip doesn t answer Action please contact your Ateis dealer Slave zone LEDs management chip doesn t answer Action please contact your Ateis dealer Connection to slave XX has been lost Action Check the slave XX status power fault LEDs and condition Check corresponding link cable condition If necessary exchange the unit The master voice amplifier gain drops down to 0 Action Check the master voice amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The slave XX voice amplifier gain drops down to 0 Action Check the slave voice amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The master voice amplifier gain drops out of tolerance Action Check the master voice amplifier status power fault LEDs and condition Check amplifier wiring condition Page 248 of 260 DIVA8 SYSTEM SXX V GAIN LOW XX 1 15 M01 V GAIN HIGH SXX V GAIN HIGH XX 1 15 Music amplifier f
186. ration only codes with at least 1 zone allocated to it Examples codes 5 and 12 Answer No global fault all codes free with no fault ESP05SP12SP Immediate global fault all codes free with no fault EIO5SP12SP Deferred global fault all codes free with no fault EDOS5SP12SP No global fault code 5 occupied by local source ESP05 12SP No global fault code 12 occupied by modan source ESP05SP12 Immediate global fault code 5 immediate fault and local busy ESP05 12SP In point to point version of the protocol the slave must send status fault report by itself each time status fault is changing MULTIPOINT PROTOCOL DEFINITIONS Slave Address is added in each command with 2 characters just after the STX character Legal values are 00 master 01 to 98 slaves 99 all slaves not used for the moment Only the slave whose address is matching the address added will answer and must add the master address 00 inside the status fault report Slaves must not send by it selves status fault reports Examples Command Answer Call on slave 2 channel 1 to code5 02P15 ACK CR or DLE CR Free channel 3 on slave 1 01C300 ACK CR or DLE CR Get status of slave 4 04E 0O0OESP05SP12SP A new Enquiry command is added to the protocol to optimize detection of absent slaves ENQ 0 2 means that the master wants to know if the slave 2 becomes again present In this case the slave 2 answers ACK CR www ateis europe com Page 224 of 260
187. rator parameters To access the tone generator parameters window click on Monitoring under the DIVA icon in the system window Then click on the Tone Generator button Tone Generator Ef Lev Jau dB Frequency Enable 1K Tone Hz www ateis europe com Page 188 of 260 DIVA8 SYSTEM Mute here you can mute the generation of the pilot tone Frequency Hz allows to choose between 18kHz and 20kHz pilot tone by using the drop down menu Target Level dB allows to increase the tone level up to 10dB Enable 1K Tone ticking this option allows to add a 1kHz signal to the current pilot tone www ateis europe com Page 189 of 260 DIVA8 SYSTEM 9 43 Use RS232 Ports The RS232 allows to connect DIVA to an external DIVA such as a firepanel a Modbus host a Vox net network or a remote access master For RS 232 pinning please refer to the How to wire RS232 chapter 9 43 1 For Modbus In this chapter we will see how to set the RS232 port of DIVA to communicate with a Modbus server e To access the RS232 port settings click on the RS 232 Port1 or RS 232 Port2 tabs As the settings are the same for both ports only one will be introduced Master 1 4 Note Drag Audio sources here R5 232 Partl R5 232 Port2 Voice Amp Baud Rate 38400 Front Panel Setup Data Bits g Parity No Parity Music Amp Stop Bit f Ethernet PSSs Protocol None Procedure e On RS 232 Port
188. re are eight rows of 4 LEDs that show in real time mode the zones status EVAC FAULT ALERT PAGE SELECTED Zone selection buttons Select or deselect zone for manual routing www ateis europe com Page 17 of 260 DIVA8 SYSTEM 3 6 DIVA8S Rear View Evacuation Inputs Logic and External Fault inputs Master Slave Link 24VDC Input Speaker Zone 100V Signal i Links IN Terminator Slave ID Logic Output utputs QUT Logic and external fault inputs There is eight logic inputs that are two states input open contact close contact External faults input are normally reserved to connect security devices like monitored power supply Those two inputs can be used to put DIVA into a security mode security mode will be discussed in the event chapter Evacuation inputs Evacaution inputs are contact inputs that allows the monitoring of external contact They also can be used in UGA mode trigger by a voltage polarization change This connector supplies a 24VDC source Master Slave link Connectors to create a master slave DIVA system 24VDC input 24VDC power supply for battery operation Speaker zone outputs Eight speaker zone connectors splitted in A and B line 100V Signal links 100V input to receive 100V signal from an amplifier connected to another DIVA M or S unit 100V output to send 100V signal to others DIVA M or S unit Terminator This switch define t
189. reate the TCP IP link between the DIVA and the PSS microphone console In order to do so follow the next steps e On the Master window click on the Ethernet PSS button Master 1 Note Drag Audio sources o NN Machine PSS PSM Voice Amp Music 1 Enable Is L Music 2 Enable Mic Line Enable O Message Enable E O Fireman Enable PSS PSM Enable Music Amp e AddaPSSG2 E to the system by clicking the Add button Ethernet PSS Management www ateis europe com Page 135 of 260 DIVA8 SYSTEM e As for any TCP IP based product one have to search for it on the network To do so go in the menu Tools gt Device Search gt Ethernet PSS tab Click on the Search button Once the search process ends it should display all Ethernet PSS on the network If for some reason no Ethernet PSS is found please enter the searched TCP IP address range by clicking on the Edit Search Group button Device Search Edit Search Group DIVA Machines Ethernet PSSs D P Address Group IP 192 168 10 205 239 211 34 32 When the Ethernet PSS has been found return to the Ethernet PSS management window see below With the Serial Number drop down menu choose the corresponding PSSG2 E serial number The IP address should be automatically filled You have the possibility to change the name of the console by entering a new name in the name cell Select the
190. relay please read this www ateis europe com Page 98 of 260 DIVA8 SYSTEM Play Message Event Type Play Message Pony 20 Zero equals highest Name Event 1 Attrib Security NextEvent Event 2 Start Impulse Stop Impulse _ Enable m ength iid Pulse 50 Busy Relay Enable IST Message l Play Mode Continuous Conflict O Eancel All Coexist Repeat Times 1 Pre define Zone __ Pre define Zone Enable Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished www ateis europe com Page 99 of 260 DIVA8 SYSTEM Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a
191. rew connectors for 0 dB audio e audio output from PPM PSM CD16 microphone gt Audio Output not used with PSM CD16 audio input to PPM speaker gt Audio Input Not used with PSM CD16 1 input for additional 24V power supply Depending on distance between LAP and PPM URC or PSM CD16 to the VACIE you will have to put an external power supply 1 internal switch for PPM PSM CD16 Master or Slave selection Slave features are not available PPM and CD16 1 internal switch for System or Local power supply selection PSSG2 The PSS G2 Touch paging microphone console is a man machine interface which allows paging call messages broadcasting and DSP matrix parameter control DIVA8G2T can handle one PSS G2 unit connected to a secured bus Its back lit touch screen is designed for simple and user friendly operating Various operating levels with password protection make the PSS G2 a versatile device that fits well in a commercial shopping center as for an industrial high security environment All paging parameters needed for site operating can be programmed zones assigned to the different buttons name of zones group of zones messages triggering levels adjustments and pre call chime but also for fader control button control or event control www ateis europe com Page 21 of 260 DIVA8 SYSTEM A total of twelve keys on fourteen pages allow zone or group of zones selections Each key contains a color changing field indic
192. rify the firmware and FPGA version that are installed into the DIVA device From the FUNCTIONS MENU Use arrow keys to access the VERSIONS DISPLAY menu Press OK Use arrow keys to access the FIRMWARE VERSION submenu Press OK The current firmware version is displayed Press OK or ESC to go back to the PROGRAM VERSION menu Use arrow keys to access the FPGA VERSION sub menu Press OK www ateis europe com Page 46 of 260 DIVA8 SYSTEM The current FPGA version is displayed Press OK or ESC to go back to the VERSIONS DISPLAY menu e Press ESC to go out of the menu 8 1 4 12 CRC Display From the CRC DISPLAY menu you can verify that the firmware and or configuration stored in the DIVA aren t corrupted From the FUNCTIONS MENU Use the arrow keys to access the CRC DISPLAY submenu Press OK To check the firmware CRC choose the FIRMWARE CRC sub menu with arrow keys Press OK The current firmware CRC check code is displayed Press ESC to go back to the CRC CHECK CODE menu The current firmware CRC code is displayed To check the configuration CRC choose the CONFIG CRC sub menu with arrow keys Press OK The current configuration CRC check code is displayed Press ESC to go back to the CRC DISPLAY menu Press ESC to go out of the menu Note The firmware CRC check code can be found in the software on the update window Menu Tools gt Update The configuration CRC check code is displayed when a
193. s highest Name Event 14 Attrib Security Next Event None Stop Impulse Enable Logic Output Channel Device faut 1 2 s 4 s e r ey Master Music Source Music 1 OK Cancel Type display the type of event you are creating or modifying Name here you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an output contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms To learn more about output relay please read the How To Use Output Relay e Music Source here you can choose the music source you want to switch on off 9 23 3 14 Toggle Music ON OFF By Zones The Toggle Music On Off By Zone event have been created to turn music on or off with one same trigger in some zones As example using a contact one closing will switch on music one more cl
194. sages can only be seen if they are a part of the configuration Reading the message memory of the DIVA does not put messages in the configuration You ll have to reverse the messages in order to be able to use them in the configuration 9 25 Use a Fireman Microphone In order to use the fireman microphone first drag and drop the fireman microphone from the Design Component Section to the Master window Double click the fireman microphone icon to enter the Fireman Microphone window see below Here is a list of controls and indicator in the fireman microphone window www ateis europe com Page 115 of 260 DIVA8 SYSTEM Fireman Microphone Paging E vent Setting v Security v Evacuation Paging Mode Zone Release Time 5 Level Overflow Push To Talk Lock To Talk Advance Setting by clicking the Edit button you will enter the fireman microphone event setting window Please see below Note the fireman microphone default paging mode is always push to talk By default the priority of the fireman microphone is set to zero the highest priority available and the security and evacuation options are ticked The fireman microphone have been designed to be an emergency paging element so be careful when changing priority and security settings Security by ticking security you will allow user to make a call when DIVA is in security mode Evacuation ticking this option will make the fireman microphone an ev
195. sconnect End 2010 11 23 21 57 17 6 Slave 2 Disconnect Start 2010 11 23 21 57 17 No displays the number of the log file occurrence No 1 is the youngest Message displays the log file message corresponding to the record For more information about Log file messages please read this Start End displays if the incident started or ended Date displays the date at which the event happened Time displays the time at which the event happened www ateis europe com Page 218 of 260 DIVA8 SYSTEM 10 Communication Protocols This chapter will lead you into the different protocol implemented into DIVA Notifier Modbus Vox net 10 1 Notifier Introduction The purpose of this document is to clarify the development tasks for communication between ATEIS Voice Alarm System VAS and NOTIFIER Fire Panel FP This document is based on the NOTIFER Functional Specification 103000 Series of Intelligent Fire Alarm Control Panels Protocol for RS232 link to third party equipment and the different e mails we exchange during the last weeks Physical support RS232 interface Full duplex mode Half duplex mode will not be developed Baud rate configurable 8 data bits 1 stop bit No parity Low level Data Protocol Transmission from Fire Panel to Voice Alarm System e Start character r gt Ox3E e Identifier character p 0x49 e Body of message Sequence of printable characters e End character 1
196. sentation DIVA8M responds to public address requirements and Voice Alarm EN 54 16 compliance for small to medium installations The DIVA8M module unit houses audio digital signal processing DSP a matrix a digital message player a fully monitored fireman microphone amplifiers monitoring with switchover to backup amplifier and loudspeaker lines monitoring It can process and route one PSSxxDT security microphone console or up to eight cascaded PSM paging microphones and two 0 dB audio inputs plus one Mic Line input into 2 different channels Music Voice Each input is fitted with volume controls and equalizers All audio inputs feature contact and VOX activation ideal when using the cordless microphone for example Up to 45 minutes of digital messages can be downloaded and recorded as WAV files directly from a computer into DIVA8M Two messages can be played simultaneously in different zones One of the messages can be used as a chime for the PSS microphone Nine monitored alarm inputs making it possible to obtain the pre programmed routings Each DIVA module has eight output zones with a b wiring Each zone can be routed manually or automatically to one of the system s audio channels Music and Voice The number of zones can be extended up to 128 zones with DIVA8MS Slave module The two Music channels can be switched ON OFF in each zone separately In case of Evacuation the Music channel can be used as a second alarm channel A DIVA
197. sh To Talk Chime Call The Push To Talk Chime Call key has to be used like the Push To Talk Microphone Call The difference is that for each call a pre chime message will be played Note don t forget to load a chime message in the general PSM page 9 29 3 Slave PSM With PSM microphones the keys configuration is identical for the Master and Slave Using slaves do not allow simultaneous microphone calls the philosophy is the first who calls has the priority The Master PSM microphone is defined as the first one in the cascade the closest to the IDA In order to achieve a PSM cluster Junction box have to be used Up to 10 PSM can be cascaded please read How to Wire PSM to learn more about the connection 9 30 Use CD16 Microphone The CD16 microphone is considered as a PSM microphone from a configuration point of view Up to 10 CD16 microphones can be cascaded The CD16 offers Cinch connectors for music inputs The CD16 music input should be configured as normal music sources in the DIVA software please read this chapter The CD16 offers also independent music source selection buttons that in addition with a configured route key will make music routing as easy as on the front panel To learn how to configure CD16 general options and keys please refer to the PSM General page and keys page chapters 9 0 0 9 www ateis europe com Page 142 of 260 DIVA8 SYSTEM 9 31 Use MIC LINE Input
198. sily defined via the GUI of the IDAxx DIVA system using a simple Matrix selection The unit offers Hold and Busy LED signals in addition to the zone LED s and these allow the easy identification of selection Busy signals for the user All buttons can be freely programmed from software and each button can be programmed for Push To Talk or Latch functionality The unidirectional condenser microphone means high quality directive pick up from the user and hence less interference from the surroundings thanks to the cardioid polar pick up pattern The IDAxx system can accommodate up to 64 PSMs in the system and up to 10 PSMs on one IDAxx and up to 256 zones in total DIVA only allows 10 PSMs in the system The RS485 communication protocol offers daisy chaining of up to 1000 m on a simple CAT5 cable and yet makes outlets easy to connect via a standard RJ45 connectors www ateis europe com Page 20 of 260 4 4 DIVA8 SYSTEM JB Junction Box Easy chain connection of LAP peripherals URC and PPM or VACIE peripherals PSM CD16 using standard shielded CAT5 cables KEY FEATURES 4 5 5 x RJ45 e Connection to previous JB or LAP bus on the first JB Call stations bus VACIE system e RS485 SIDE for URC connection Easy connection to a Master PPM using the supplied 10 pins cable Connection to first Slave PPM PSM Slave features are not available on PPM and CD16 e MAIN OUT connection to next JB 2 internal sc
199. simply clicking in the name box Net ID displays the current slave unit ID To add a slave unit to your configuration simply click the Add button To delete a slave unit from your configuration select the slave in the list and press the Delete button For each slave added you can specify its Net ID Click in the Net ID box and use the appearing drop down menu The ID must fit the slaves hardware ID settings e Once all the slaves have been set in the configuration make sure to verify their firmware version using the version menu and update version if needed When slaves are configured as existing in all zone selection sub menu the slaves zones will appear as selectable as well as slave GPIO relay see below for an example Using slave does not change the way you ll program the DIVA it only add more contacts and zones www ateis europe com Page 82 of 260 DIVA8 SYSTEM Start Impulse Enable Length Static CK Relay Busy Relay CITN 1 l Bu olojo nee eee 9 20 Set Speaker Parameters Setting The speaker parameters setting allow to route to the PSS internal speaker and the DIVA internal speaker music sources mic line and messages In order to route those different devices go on the Master window and
200. t an event But as soon as the first event is finished or stopped the second event will be launched The second event could activate the start of a third event and so on In each event edit page there is a next event drop down menu see below In this menu you will be able to choose between all the existing events Next Event None Events could also be looped The diagram on figure below explains it visually EVENT1 EVENT 2 According to the looping event diagram when selecting next event for Event 2 choose Event 1 As soon as you select an event that is before in the chain a new Circular Times selector is visible just beside the next event drop down menu see below This selector permits to define how many times the events loop will be repeat or to make it continuously repeating This is a quick way to loop different language evacuation messages for example www ateis europe com Page 93 of 260 DIVA8 SYSTEM Next Event Event 1 Circular Mode Continuous Once you go back in the event window You can see multiple information about sequences like the next event that is called Next event the number of time the loop is repeated Times and the event or action that is linked to one event Link By see picture below Circular Times 3 Master M aster 1 Event Link By E Event 1 B Play Message Event 2 vent 2 uU Play Message Event 3 Event Event 1
201. t and g Screen Status Indicator VACIE button LED buttons Display Indicators Fireman All Call Mic Cancel Control Attenuator Selection message Input Button Buttons Bistions Knobs Buttons From left to right and from up to down Evacuation button Initiates the evacuation process in manually selected or pre defined zones Power indicator LED Indicates the power status of the DIVA Navigation buttons Plus minus ESC OK up arrow and down arrow buttons allows the navigation inside menus Color screen The screen displays all status information menus and date time Faults and status indicators There are four mains status LED on the DIVA front panel G Fault System Fault Evacuation By Pass Mode Vacie indicators There are eight rows of 4 LEDs that show in real time mode the zones status EVAC FAULT ALERT PAGE SELECTED Integrated monitoring speaker The DIVA integrates a front panel monitoring speaker that can monitor different audio sources software configuration Fireman Mic input Monitored fireman microphone input Reset button Generates a global software reset machine reboot All Call Cancel button Selects all zone in the system or reset the current zone selection Music control buttons The ROUTE button validate the zone selection SELECT button permit to toggle between music source 1 2 ornone The two music source indicators light when the corresponding source is used www ate
202. t be able to add PEQ on that input On one input you only have one filter location and can use either PEQ or Hi Lo Pass filtering Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Hi Low Pass I Voice Channel Generator e Adjust the PEQ parameters to suit your needs www ateis europe com Page 178 of 260 DIVA8 SYSTEM e Bandwidth Oct here you can adjust the Q factor of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell e Frequency Hz here sou can adjust the central frequency of the PEQ either by using the slide bar arrow key or by entering directly the value in the dedicated cell e Gain dB here you can adjust the PEQ gain either by using the slide bar arrow key or by entering directly the value in the dedicated cell PEQ Overflow Signal indicates if there is an overflow after the addition of the PEQ to the base signal Bypass All by clicking on the Bypass All button you will instantaneously bypass all three PEQ filter The first PEQ filter can be changed to a High pass filter with the corresponding drop down menu The last PEQ filter can be changed to a Low Pass filter with the corresponding drop down menu By clicking on the Graphic button you will enter the PEQ graphic edition window You will be able to adjust gain and central frequency of each PE
203. t before music source will be activated A correct setting of the attack time can avoid inopportune activation of the Mic Line source peak signal activation The Attack time can be set from 0 ms to 5000 ms Release Time ms As opposed to the Attack time the Release time is the amount of time for which the signal have to stay under the threshold point before deactivation of the Mic Line sources A correct Release Time can avoid inopportune deactivation of the music source pause in speech The release time can be set from 0 ms to 5000 ms www ateis europe com Page 145 of 260 DIVA8 SYSTEM Setting those parameter correctly needs some experience so be careful and please test it to learn more about the behaviour of this option Once your modulation detection parameters are adjusted you have to edit the advance setting for the Mic Line please refer to the Use Mic Line Input general chapter 9 31 2 From Logic Input Mic Line routing can be operate by external trigger that means with the help of the logic evacuation or even external fault inputs In order to access the logic inputs menu go on menu View gt Logic Inputs The Logic Inputs page will pops up see below Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger To learn more about the Logic inputs see How t
204. t contact Logic Output channel in two different manner Static will close it until the event stop and Pulse will generate a closing pulse whose length can be defined from 50 to 60000 ms Stop Impulse This option is used to create a closing contact pulse when the event is finished The length of the pulse can be defined from 50 to 60000 ms e ACK Relay here you can set the closing of a Logic Output Channel relay as soon as zones where an event has to be played are freed from higher priority events Busy Relay here you can specify an Logic Output Channel relay that will be closed as soon as a higher priority event is playing in common zones To learn more about output relay please read the How To Use Output Relay Message by using the drop down menu you can select in the list of stored message a message to assign to the event e Play Mode by ticking continuous the message will be played until a trigger happen You can also specifiy a number of repeat time e Conflict you can choose between Cancel All or Coexist Repeat Time if continuous not ticked you can choose a number of time this event will be repeated e Pre define Zone here you can specify the pre define zone s where the message will be played Zone Selection here you can specify the zone s where the call will be played OK will accept the current setting and close the window Cancel will annulled the current settings and close the window Note Mes
205. t gain and central frequency of each PEQ by moving the yellow cursor Bandwidth is controlled by the orange cursor www ateis europe com Page 180 of 260 Music Amp DIVA8 SYSTEM 30 10 12 5 16 20 25 31 5 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K1 25K1 6K 2K 2 5K3 15K 4K 5K 6 3K 8K 10K12 5K 16K 20K 25K www ateis europe com Page 181 of 260 DIVA8 SYSTEM 9 39 Use Compressor Limiter In DIVA software you can add for each audio input a compressor a limiter or a combination of both limiter and compressor In order to do so please follow the next few steps In the Master window double click on the DIVA icon The DSP configuration window will pop up Note if no audio sources have been set into the configuration the corresponding Filter and Compressor Limiter location will be grayed e Drag and Drop from the Design Component Section either Compressor limiter or compressor limiter to the right location Compressor Limiter is a component that is either a compressor or a limiter Compressor Limiter is a component that offers both compression and limitation o The DSP configuration windows should look like follow f Master 1 DSP Configuration Note Drag Audio components here Compressor Limiter Filters Bypass I Hi Low Pass I Tone Fireman MIC Comp Limiter Bypass M Ei i Gasa Music Channel PSS Comp Limiter Bypass Double click o
206. t of all events that are existing in the current configuration You can edit one existing event by selecting it in the list and then click the Edit button Select one in the list or create a new event Once the event is selected click on the select button to affiliate the event to the task that is created Selectif it is a Single occurrence task or a Cycle task For Cycle task see picture below Occurrence You can choose the way the scheduler task will be repeated The scheduler offers yearly repeated event monthly weekly daily hourly and minutely The weekly option offers days of the week activation options see below www ateis europe com Page 168 of 260 DIVA8 SYSTEM Scheduler Task Trigger Event General D Name Prionty_ Secunity Asad Enable v Enable 1 Event 1 20 False Occurence Yearly Monthly Sunday Monday Tuesday Wednesday Thursday Friday Saturday Hourly Minutely End No end 02 08 2010 Number of Times Time 14 35 End by Date 5 D New Edt Event 1 lv OK x Cancel Range here you can specify the date and time for the first occurrence of the scheduler task You will also specify the way the task will end no end end after a certain amount of repeated time or end at a specific date and time e To create a scheduler task follow the next steps o Choose the way the scheduler task will be repeated every minutes hour day week month or
207. takes a 2U 19 rack space and generates little heat itself Consider leaving enough ventilation space above and below the unit Do not mount the DIVA directly above heat generating devices like power supplies or power amplifiers Power connection DIVA accepts 24 VDC power supply as well as 230 VAC power supply In order to be EN54 compliant use a BECS battery charger and power supply and connect it on a 4 way euroblock connector respecting the polarity 3 2 54 Installation Requirements In order to comply with the EN 54 standard installation requirements please carefully read the followings manuals BCS 150 user manual BECS150 10UMSO01 VO1RO1 DPA amplifiers series user manual DPA 10UMS01 Vo1RO1 PSSG2 user manual PSSG2 10UMS01 V01R01 1016 user manual cD16 10UMSO1 VOIRO1 Those manuals can be downloaded from ATEIS websites or could be required from any branch office In order to fully understand all the DIVA system requirements regarding standards please read also the following guides DIVAS service manual DIVA8MG2 M S 10SMSO01 VOTRO1 DIVA8 reference DIVA8MG2 M S 10VRS03 VO1RO1 DIVA8 VACIE documents DivA8MG2 M S 10VDSO1 VO1RO1 and DIVA8MG2 M S 10VDSO2 VO1RO1 DIVA8 system VACIE EN54 16 tesing guide DIVA8 System VACIE EN54 16 testing guide www ateis europe com Page 14 of 260 DIVA8 SYSTEM 3 3 DIVA8M Front View Evacuation wid Navigation Faul
208. teis europe com Page 257 of 260 16 DIVA8 SYSTEM Safety Declaration Warning This sign indicates a potentially hazardous situation that can result in death or serious personal injury Do not expose the DIVA to extreme temperatures direct sunlight humidity or dust which could cause fire or electrical shock hazard Keep away water or other liquids from the DIVA Otherwise fire or electrical shock may result Connect the power cord only to an AC outlet of the type stated in this Owner s Manual or as marked on the unit Otherwise fire and electrical shock hazard results When disconnecting the power cord from an AC outlet always grab the plug Never pull the cord A damaged power cord is a potential risk of fire and electrical shock hazard Avoid touching power plugs with wet hands Doing so is a potential electrical shock hazard Take care for correct polarity when operating the DIVA from a DC power source Reversed polarity may cause damage to the unit or the batteries Avoid placing heavy objects on power cords A damaged power cord is a fire and electrical shock hazard Do not cut scratch bend twist pull or heat the power cord A damaged power cord is a fire and electrical shock hazard Ask your ATEIS dealer for replacement Turn off immediately the unit remove the power cord from the AC outlet and consult your ATEIS dealer in any of the following circumstances e Smoke odor or noise getting out of
209. tenance operator and trained persons Level has all the right of level 2 www ateis europe com Page 68 of 260 DIVA8 SYSTEM O Store a new configuration file o Manage messages o Maintenance operation To enter level 3 a password is needed e Level 4 is for authorized by the manufacturer to either repair the unit and or alter its firmware Level 4 has all the level 3 rights Update firmware Repair To enter level 4 a password is needed 9 11 Enter Password For process like storing and updating you will need a username and a password see How To Use User Management There are two different way of connecting to your account from front panel or from software From front panel When trying to attempt protected operations you will have to enter you user name and your password Use the arrow keys to select the right letter or number Click OK enter the next letter or number repeating the same procedure you have enter the right user name press once the down arrow key to find APL Press OK this will validate you entry DIVA will ask to enter your password repeat the same procedure to enter password From software You will be automatically login after first store update network options change ethernet settings change Effectively DIVA software will ask you to enter a valid user name and password and will remember your username and password until you exit or logout of
210. ternal fault inputs In order to access the logic inputs menu go on menu View gt Logic Inputs The Logic Inputs page will pops up see below www ateis europe com Page 124 of 260 Close to Trigger DIVA8 SYSTEM Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger Close to Trigger To learn more about the Logic inputs see How to Use Logic Inputs The idea is to use logical trigger to start an event Event types for operation on music are listed below You can find more information on those events in the chapter How To Use Events Music On Music Off Music On By Zones Music Off By Zones Toggle Music On Off Toggle Music On Off by Zones In order to associate a event to a logic input trigger click on the Start button under Event Setting The Events Selection window will be open see below www ateis europe com Page 125 of 260 DIVA8 SYSTEM Events Selection Name Priority Type Security Name Type Security Select All 4 Shift Up a Insert DSSS Delete Select None Shit Down Cancel On the left side you will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type se
211. the current configuration file To log out go to the menu User Logout Default User Name and Password are ATEIS4 and ATEIS4 highest level ATEIS3 and ATEIS3 ATEIS2 and ATEIS2 ATEIS1 and ATEIS1 lowest level Note 1 username and password entry are not case sensitive they are always filled in capital letters Note 2 in order to have to highest level control please use the ATEIS4 default account Note 3 configuration won t be stored if no level 4 account exist 9 12 Verify Diva Versions Before checking the DIVAs firmware versions you should connect to the machine trough TCP IP see How to Search Device chapter In order to verify that the current software correspond to the DIVAs units firmware please follow the next steps www ateis europe com Page 69 of 260 DIVA8 SYSTEM Go in the menu Help choose Version Then the following window should pop up Version Compatible Current CPLD Version Version Software AOMAFI 20017 Firmware 20 17 FPGA Net Card Slave ID 01 Slave ID 02 Slave ID 03 Slave ID 04 Slave ID 05 Slave ID 06 Slave ID 07 Slave ID 08 Slave ID 08 Slave ID 10 Slave ID 11 Slave ID 12 Slave ID 13 Slave ID 14 Slave ID 15 Close Click the Read button The Compatible Version displays shows the firmware version that will be working with the application software version currently installed Current Version displays shows the current DIVA units fir
212. the following IP address IP address Subnet mask Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Select Use the following IP Address and enter values for IP address Subnet Mask Gateway If you are not sure what settings you should apply please ask your network administrator e Select Obtain DNS server address automatically this would work most of the time In windows for one network connection card you can specify several IP addresses e Inthe Internet Protocol TCP IP Properties dialog box click on advanced Advanced TCP IP Settings g Settings DNS WINS Options IP addresses IP address Subnet mask 129 2 5 141 255 255 255 0 Default gateways Gateway Metric 129 2 4 1 Automatic Ca J Cea Come Automatic metric pui e Under IP address click the Add button www ateis europe com Page 54 of 260 DIVA8 SYSTEM Enter the additional IP address and Subnet Mask For more information about IP addressing you can read the following article IP addressing on Wikipedia 9 2 Configure Network Options In order to be able to communicate with DIVA master units you have to set your network parameters In the Network options page you can specify your network card the UDP port value as well as the RS232 port number Options Ethernet Network Card Broadcom NetXtreme
213. the unit Foreign objects or liquids get inside the DIVA e The unit has been dropped or the shell is damaged The power cord is damaged If you continue using the DIVA fire and electrical shock may result Do not drop or insert metallic objects or flammable materials into the unit as this may result in fire and electrical shock Do not remove the DIVA s cover as there are exposed parts inside carrying high voltages that may cause an electrical shock Contact your ATEIS dealer if internal inspection maintenance or repair is necessary Do not try to make any modifications to the DIVA This is a potential fire and electrical shock hazard Avoid the DIVA s ventilation slots to be blocked Blocking the ventilation slots is a potential fire hazard Caution This sign indicates a potentially hazardous situation that can result in moderate or minor personal injury and or property damage To prevent the unit from falling down and causing personal injury and or property damage avoid installing or mounting the unit in unstable locations www ateis europe com Page 258 of 260 DIVA8 SYSTEM Leave enough space above and below the unit to provide good ventilation of the DIVA If the airflow is not adequate the DIVA will heat up inside and may cause a fire Operate the DIVA in an environment with a free air temperature of between 0 C and 40 C 32 F and 104 F Turn off all audio equipment when making any co
214. ting system s clipboard Delete Deletes the active selection Undo Will undo the last actions Redo Will redo the last actions or will retrieve the last state in case undoing too far Cascade Cascades the current opened windows Tile Tiles the screen with the current opened windows Arrange Icon Arranges Icons in a window where possible e Lock Locks the software Note if no password were specified every user can unlock the software Help opens the user manual www ateis europe com Page 34 of 260 DIVA8 SYSTEM Preset List allows choosing a preset in the exiting ones Name allows modifying the names of the exiting presets Add Preset Add a new Preset to the system By default the new preset is named Untitled Delete Preset deletes the preset chosen in the Preset List Preset Save allows saving new parameters to the preset in the Preset List Preset Load allows loading the preset selected in the Preset List Compile Compiles the current configuration and displays eventual errors Store Upload configuration parameter into the DIVA s parameter memory Reverse Downloads the DIVA configuration in the computer Connect Establishes data connection to the machine s in order to monitor or adjust parameters online Disconnect Disconnects DIVA software from the machine s Audio Enable Enables DIVA s audio processing Audio Disable Disables DIVA s audio processing Stop All Events Stops all runni
215. tions Ay amm Only Fireman or Pss Paging at Front Panel Setup System Select Zone Release Time Music Amp Monitoring No Release Time Ethernet PSSs Release Time Dis e Only Fireman or PSS paging at the same time if ticked this option will only allowed on paging microphone at a time either the fireman microphone or PSS microphone To avoid conflict verify both microphone priority before enabling this option e System Select Zone Release Time Once a manual zone selection is made on the front panel the selection could be held in memory for a certain amount of time If the selection should remain active unless manual deactivation enable the No Release Time option If you want to enable a time out on the zone selection which means that the manual selection will be disabled enable the Release Time option and set the desired time out value www ateis europe com Page 65 of 260 DIVA8 SYSTEM 9 10 Use the User management To access the user management window go on the menu User gt User Management User Management PE AecoutName Level Authority Level Hit ATEIS1 Lowest ATEIS2 Mid ATEIS3 High ATEIS4 Highest Delete Add 4 Edit Er Close The picture above shows the main page of the user manager In this page you will be able to add new user account delete account and modify account settings The List below describes the different displays Account
216. to associate an event to a logic input Click on the Start button under Event Setting The Events Selection window will be open see below www ateis europe com Page 149 of 260 DIVA8 SYSTEM Events Selection Name Security Name Priority Type Security Delete Select None Shit Down Cancel Event Select All Select All Shift U m mra Select None elect None On the left side you will find the list of existing event To create a new event simply click on New under Event As soon as you click on the New button the software will ask to choose a event s type see below New Event Master Select Master 1 Event Type Music On In order to select an event s type use the drop down menu Then click OK After you have press OK you will return to the Events Selection window To edit your new event settings select it by clicking on the right line and then click Edit Note don t click in the square selector The corresponding event s type window will pop up After your event settings are complete click OK The last step is to affiliate the event created with the logical input In order to do so tick the square selector and click on insert Note you can associate more than one event to an external trigger as well as creating event sequences To learn more about it please read this www ateis europe com Pa
217. top button to stop playing the message Press the Save Level button to save the current level into the memory www ateis europe com Page 88 of 260 DIVA8 SYSTEM Stored List MessageName Securty Evac_ Size Level dB na Current Message Level 0 gt gt Play m Stop N Save Level Master 1 Slave 01 1 2 5 6 7 2 4 5 6 7 Note Each message have individual level setting so each message could have different level Keep in mind that the message level cannot be set differently for each zone www ateis europe com Page 89 of 260 DIVA8 SYSTEM 9 23 Use Events As briefly explained before the DIVA action is based on event philosophy Each action is described in event Event can be started by different type of trigger The events created by any manner are all listed in the event page window To access this window go to the menu View gt Event In the Event window you can managed all the event created and see the priority hierarchy next event called sequences and calling event Master _ Master 1 Play Message o 2 Event 2 LJ Fireman Paging Select All Event Typ e wm Delete j i Close Fireman Mic Paging Master here you can select which master events list you wan to work on Square Selector you can select event s by ticking the squar
218. trol can be affiliated to several preset to do it assign the control to all the preset 9 41 Create a Monitorable Button The surveillance of a contact line a microphone line or speaker line is based on the same measurement An internal voltage source is applied to the input or output terminal By measuring this tension it is possible to know the state of the input or output With a normal contact see picture below you only will be able to measure two states Open or Shorten Shorten when contact is closed forces the voltage source to zero www ateis europe com Page 187 of 260 DIVA8 SYSTEM DIVA Measurement Unit EVAC1 Contact Voltage Button Source EVAC1 FigAnnexe 1 In this case the measurement unit can only detect OV closed or 4 4 V opened In order to have different state measurement like open line and short circuit we need to add a resistor network to the end of the line see picture below DIVA Measurement EVAC1 __ Contact Voltage Button Source FigAnnexe 2 Using the resistor Network the measurement unit can detect 4 different states 1 3 V 2 V 2 7 V and 4 4 V The 4 states correspond respectively to Shortcut Closed Contact Opened contact and Absent open line According to the FigAnnexe 2 you have a fully monitored line responding to the security norms 9 42 Use Tone Generator In the DIVA software you can control the tone gene
219. ttery back up device 1x PSS G2 Paging console www ateis europe com Page 11 of 260 DIVA8 SYSTEM 2 2 Application Example 2 IP Intercom night entrance BGM and security server IP Call stations Entrance Maintenance and service PC Parking PSS G2 Restaurants amp zones2x500W 2 2 zones 2x 250W E i i 8 zones 2x 250W PSM8 16 zones 2x 1000W This tutorial describes a PAVA system VACIE which is used for voice evacuation with an automatic link to a firepanel system FACIE for a resort with several buildings linked over IP The DIVA System concept stands for a reliable and affordable system solution where each building has its own FACIE linked to the VACIE consisting of a DIVA8M Master unit with amplifiers and battery backup facilities The system consists of 4 individual PAVA equipment sets that are linked over IP A server with special software Vox Net surveys the audio data connections between the 4 sub systems and the IP paging facilities Vox Net IP media software also provides surveyed intercom stations to be included into the system and provides multi channels BGM The standalone DIVA8M provides the fireman s operating section on the central paging facility rack and a touchscreen multi zone paging and control console This part of the system is also linked to the FACIE Depending on the situation digital power amplifiers are used 4 x 125 W 4 x 25
220. two keys are an additional way of starting and stoping events that are not selected in the message section You can start and stop any kind of event Keep in mind that each event started by a Event Start key need a Event stop key When creating an Event Start Stop key you will have to select in the existing event list the one to associate to the key www ateis europe com Page 133 of 260 DIVA8 SYSTEM F Key Setting SEE Push To Talk Microphone Call The Push To Talk Microphone Call key allows to change the behaviour of the microphone call The default behaviour for the microphone Mic Key is the locked to talk In order to make a microphone call you will have to keep the key pressed during the entire speaking process Push To Talk Chime Call The Push To Talk Chime Call key has to be used like the Push To Talk Microphone Call The difference is that for each call a pre chime message will be played Note don t forget to load a chime message in the general PSS page e Jump To Page When using a PSSXXDT that has over 12 keys it will be needed to create key that allows to jump from page to page As soon as you select the Jump To Page type of key a page selection window will pops up please select the page where you want to jump Key Setting SEE www ateis europe com Page 134 of 260 DIVA8 SYSTEM 9 28 Use PSSG2 E Microphone In order to use and configure the PSSG2 E one has to c
221. ucket RI 02860 USA Phone 401 727 1600 Fax 401 727 0003 info penton usa com ATEIS Middle FZCO LIU 11 Dubai Silicone Oasis DUBAI UNITED ARAB EMIRATES Phone 971 4 3262730 Fax 971 4 3262731 www ateis ae infoGateis ae FAR EAST CORP 2F No 60 Xing Hua 2nd Rd Taizi Taichung county 427 TAIWAN R 0 C Phone 886 4 25333820 Fax 886 4 25333830 www ateis com sales ateis com tw ATE S SE PTE LTD 209 New Upper Rd 04 631 SINGAPORE 460209 Phone 65 6456 4448 Fax 65 6451 3426 www ateis europe com ashley ateis se com sg ATE S CHINA Room 610 No 255 Wubao Road Minxing district Shanghai CHINA Phone 021 54495191 92 Fax 021 54495193 www ateis com cn sales ateis com cn Page 260 of 260
222. unit in order to route audio to physical zones The Master sends a code that will be interpreted by the slave unit From a Master point of view the code sent has no zone routing information The routing corresponding to a code is slave dependant In Multipoint mode it means that each slave can receive the same code and this code will be interpreted differently by each of them see schematics below With DIVA the maximum number of audio channels a Vox net system or a remote access that can be used is three The number of channels you need will be determined by the number of simultaneous audio stream you whish to receive One channel is the minimum however a two channel configuration is most of the time the minimum audio channel configuration recommended www ateis europe com Page 193 of 260 DIVA8 SYSTEM Point to Point Sends Code Audio Channel used Receives Code Audio Channel used code will be interpreted in zone s routing Mulitpoint Sends Destination Address es Code Audio Channel used Receives Code Audio Channel used Receives Code Audio Channel used code will be interpreted in zone s routing code will be interpreted in zone s routing DIVA configurations As DIVA will always be slave in such system the master configuration will be skipped from this chapter Please read for Vox net and IDA4M XM for more information about Master settings Point to Point In order to
223. uracy purposes will only occur every Monitoring period By default this option is set to 90s Be carefull that for standard compliancy this setting should be manipulate with care and in accordance to standard Detect Setting Active Mode there are two options for the monitoring process Periodic and Only once a day In order to comply with EN54 standards the monitoring active mode should only be Periodic If the Only once a Day option is chosen you have to specify at what time the monitoring process will be activated with the Active Monitor Period Bypass Relay action you can specify the bypass relay activation type Active Monitor period day time where the monitoring Only once a day will take act Detect Control HW Observer Mode If enabled this options in combination with the Monitor device drop down menu allows to block the monitoring process on one device This option has been designed only for commissioning and www ateis europe com Page 162 of 260 DIVA8 SYSTEM maintenance purposes Warining as soon as maintenance tests are finished you have to disable the HW Observer Mode option Current Monitor Target ID displays the current monitored device In Periodic monitoring mode you should see the display going from Master DIVA to each Slave unit In HW Observer Mode you should only see the device selected with in Monitor device drop down menu Monitor Device drop down menu allo
224. ust real time mode the level of the music sources Volume dB indicates the current output level of the music source Clip Threshold dB allows to set the threshold point for the Clip indicator Level Overflow this is a LED indicators that light up when a too high level is detected on the music source Signal indicates the presence of audio signal Clip indicates when the signal is clipping Mute allows to mute music sources independently www ateis europe com Page 127 of 260 DIVA8 SYSTEM Music Source 2 5 9 26 7 With Vox net When using a DIVA unit in a Vox net system you will have to use audio input like music sources or Mic Line to enable audio coming from Vox net In combination with the Modan protocol the audio input will be used by DIVA to braodcast audio from Vox net To configure DIVA to work in a Vox net system please read the How to Put Diva in Vox net chapters and the How to page in Vox net chapters www ateis europe com Page 128 of 260 DIVA8 SYSTEM 9 27 Use PSSG2 Microphone PSSG2 microphone is an advance touchscreen paging microphone The PSS keys can be set by the user using the PSS window in DIVA software In order to use a PSSG2 microphone with DIVA simply drag and drop the PSS microphone from the Design Component Section to the master window f Master 1 TER Note Drag Audio sources here ERT Speaker Parameters System Options
225. validation SURE OK ESC If Yes Press OK If No Press ESC www ateis europe com Page 42 of 260 DIVA8 SYSTEM 8 1 4 4 Set System Time On DIVA front panel you can set the current location time format as well as the current date and time From the FUNCTIONS MENU Use arrow keys to access the SET SYSTEM TIME menu Press OK The program displays SET YEAR Use or keys to adjust the year value Press down arrow to go to the next step SET MONTH Use or keys to adjust the month value Press down arrow to go to the next step SET DATE Use or keys to adjust the date value Press down arrow to go to the next step SET HOUR Use or keys to adjust the hour value Press down arrow to go to the next step SET MINUTE Use or keys to adjust the minute value Press down arrow to go to the next step SET SECOND Use or keys to adjust the second value Press OK to validate your entries At anytime pressing ESC will ends the date and time setting process 8 1 4 5 Stop All Events From the front panel of DIVA you are able to stop all the running events events are discussed in How to use events From the FUNCTIONS MENU e Use arrow keys to access the STOP ALL EVENTS menu e Press OK You will be asked for validation SURE OK ESC If yes Press OK It displays EXECUTE SUCCESS If no press ESC Press ESC to go out of the STOP ALL EVENTS menu Press ESC to go out of
226. ve XX music amplifier gain drops out of tolerance Action Check the slave XX music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The master music amplifier gain is higher than tolerance Action Check the master music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit The slave XX music amplifier is higher than tolerance Action Check the slave XX music amplifier status power fault LEDs and condition Check amplifier wiring condition If necessary exchange the unit Page 249 of 260 VO3 Signal failure M01 FAIL SXX VO3 FAIL Leakage fault M01 LEAK FAIL SXX LEAK FAIL Speaker line A faults M01 Z X A IMP SXX Z Y A IMP M01 Z X A OPEN SXX Z Y A OPEN www ateis europe com DIVA8 SYSTEM XX 1 15 XX 1 15 X 1 8 XX 1 15 Y 1 8 XX 1 15 Y 1 8 The master VO3 amplifier chip pilot tone amplifier is out of order Action Please take contact with your Ateis dealer The slave XX VO3 amplifier chip pilot tone amplifier is out of order Action Please take contact with your Ateis dealer Leakage impedance between master amplifiers pins and ground drops under threshold Action Check the master voice and music amplifiers status power fault LEDs and condition Check amplifiers wiring condition If necessary excha
227. vent to the button or choose an existing one using the drop down menu accessible by clicking in the Name cell Event created is by default named Event X e Click the Edit button to enter the play message event window see below Play Message Event Name Event 1 Amb O Security Type Play Message Priority 20 Zero equals highest Next Event Event 2 e FSS Start Impulse Stop Impulse Enable S a1 T2 DS TS Master E DI Enable Logic Output Channel 2 EA ojojojojojojojo o Message Play Continuous Conflict Cancel All Coexist Repeat Times 1 Pre define Zone _ Pre define Zone Enable v o 1 cows For all the settings available please refer to the following list Type display the type of event you are creating or modifying e here you can specify a name for the event created Default is Event X www ateis europe com Page 114 of 260 DIVA8 SYSTEM Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not and if it is an evacuation event or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Start Impulse Ticking this option allows user to close an outpu
228. will automatically open a popup window for parameters setting see below for the complete list ok key functions e Edit your key settings by clicking on the Edit button Key functions Zone Selection The zone selection key allows user to arrange to his will the selection of the zone As soon as the zone selection type has been selected the zone selection window will appear Simply tick the zone corresponding to your needs and click OK www ateis europe com Page 132 of 260 DIVA8 SYSTEM Zone Selection Master 1 4 2 4 5 6 7 8 All X Cancel e Route The Route key act like the one on the front panel it has to be used to validate the routage of a music source in some zones e Music Source Selection When creating a music source selection key you will have to specify the corresponding music source with the help of the musis source selection window Key Setting SEE Muic Music Level Music Level The Music Level and need to be associated with a music source The selection of the music source is made with the music source selection window Note Music Level and Music Level are two distinct keys a Key Setting SEE Speaker Level Speaker Level The Speaker Level keys act on the PSS internal speaker You can adapt PSS speaker level to your desire Note Speaker Level and Speaker Level are two distinct keys e Event Start Event Stop Those
229. wing to display references for the different devices in the system master and slaves Leakage Impedance Threshold Ohm here you can specify in Ohms the leakage impedance threshold By default the leakage impedance threshold is set to 5MOhm In old buildings sometimes this threshold has to be be adjusted Leakage Impedance Measure Ohm displays the current leakage impedance value To learn more about how the monitoring is perform please read Explanation About Monitoring Process 9 35 1 Zone Monitoring Monitoring Norma Tone Generator L Monitoring period Detect Settin Active Mode Bypass Relay Action Type Active Monitor Period Detect Control Hw Observer Mode Enabled Current Monitor TargetID 1 Warning After test is done to make sure that the mode is disabled Monitor Device Master 1 v Leakage Impedance Threshold ohm Leakage Impedance Measure ohm Zone Monitoring Voice mp Music Amp Zone Reference Dhm ReferenceB Ohm ReferenceA B Connected Source Tolerance Measure Ohm Diff 22 03 15 0 OPEN 3172 OPEN VO3 15 0 1 0 0 1 0 0 VO3 15 VO3 15 VO3 15 VO3 15 VO3 15 VO3 15 On ON amp wn 3296 OPEN OPEN F 4b 4b 4b 4b 4b 4b 4 4 Get Reference Get All Reference Reset References Reset Monitoring Zone Monitoring display Zone displays the zone number ReferenceA Ohm displays the value taken
230. word Verify DIVA versions Update Compile Store Reverse Add design Component Perform a DIVA Master Network Add DIVA8S Slave To Set Speaker Parameters Settings Add Messages Into DIVA Use Events Set up Front Panel Messages Use a Fireman Microphone Use Music Source Use PSSG2 Microphone Use PSSG2 E Microphone Use PSM8 Microphone Use CD16 Microphone Use Mic Line Input Use Logic Inputs Use Output Relay Do Phase evacuation Evac Configuration Use Monitoring Use the Scheduler Use filters Use PEQs Use Compressor Limiter Use Presets Create a Monitorable Button Use Tone Generator www ateis europe com Page 52 of 260 DIVA8 SYSTEM Use RS232 Ports Put DIVA in Vox net Page Into Vox net Configure Remote Access Wire Devices Manage Log File Note Some topics could be divided in sub topics as the procedure could induce multiple procedure to achieve the main goal 9 1 Set Computer Network Parameters Before attempting to connect to a DIVA through TCP IP make sure that your computer Ethernet settings are corresponding to the one in DIVA You have two possiblities to make them compatible either change manually change the DIVA Ethernet settings or adapt your computer Ethernet settings DIVA s default ethernet settings IP address 192 168 100 100 Subnet Mask 255 255 255 0 Gateway 192 168 100 1 To check and or modify your computer
231. xactly as the front panel route button It is the way to validate a music source and zone selection e Music Level Music Level From the PSS you can create keys to control the music sources level The Key created that way is affiliated to one source So for Controlling both sources level you will have to create four keys two for Source one and two for source two f Key Setting SEE Example 1 procedure to route music source 1 to zone 2 4 and 6 and music source 2 to zone 3 5 and 7 Create Zone Selection key type for zone 2 3 4 5 6 and 7 Named them accordingly Create a ROUTE key Create two Music Sources Selection keys Named them Music 1 and Music 2 Store your configuration into DIVA To route Music 1 in zone 2 4 and 6 press the Music 1 key then press the zone 2 4 and 6 and finally press the ROUTE key e To route Music 1 in zone 3 5 and 7 press the Music 2 key then press the zone 3 5 and 7 and finally press the ROUTE key Example 2 procedure to increase and decrease music source 1 level e Create a Music Level key and a Music Level key Named them Music1 Level and Musici Level To increase music source 1 level simply press the Music1 level key To decrease music source 1 level simply press the Music1 level key 9 26 5 From Logic Input Like with the PSS music sources routing can be operate by external trigger that means with the help of the logic evacuation or even ex
232. you can specify a name for the event created Default is Event X Priority here you can adjust the priority of the event 20 is the lowest 0 is the highest Attrib here you can specify if this event is a security one or not See Common Option to learn more about the security option Next Event here you can select the event to start after the current one is finished Zone Selection here you can choose in which zones audio will be muted www ateis europe com Page 112 of 260 DIVA8 SYSTEM 9 24 Set up Front Panel Message There are three message button on the front panel Evacuation Alarm and Test In order to assign play message events to those buttons follow the next steps Access the front panel setup window by clicking on the Front Panel Setup button in the master page see below Master 1 Note Drag Audio sources here Machine 55 5 Voice Amp Music 1 Enable Music 2 Enable Mic Line Enable Message Enable Music Amp Fireman Enable Ethemet PSSs PSS PSM Enable Front Panel Setup Front Panel Setup Event EH Name Play Message New Edit New Edit Mew Edit New Edit All Call Range Setting At the left of the window you will find the button name You can set an event for only one button two or all www ateis europe com Page 113 of 260 DIVA8 SYSTEM In the corresponding line click on New to assign a new play message e
233. ystem file DIVA8 SYSTEM File Edit View User d Mew Ctl N Open Ctrl O Open Autosaved Recent Files Exit Ctrl Q Save as Opens the Save As dialog window to choose file path and name Open Opens the Open dialog window to choose an existing file path and name Open autosaved Opens the last automatically saved file Recent files Pathname Quick access to recently used files Print Starts printing Exit Terminates the current DIVA session after asking to save modified files www ateis europe com Page 29 of 260 DIVA8 SYSTEM 6 2 2 Edit Here you will find all the common basic edition tools of windows based software Undo ctrl z Will undo the last actions Redo ctrl y Will redo the last action or will retrieve the last state in case undoing too far Cut ctrl x Cuts out the active selection and copies it to the operating system s clipboard Copy ctrl c Copies the active selection to the operating system s clipboard Paste ctril v Pastes the content of the operating system s clipboard Delete Del Deletes the active selection 6 2 3 View The commands in this group are used to call closed or invisible control windows and toolbars Preset List LED Display Status Event Message Scheduler GPIO Evac Configuration Yox Net Editing D Language Toolbars e System opens the Design Component Section sub window

Download Pdf Manuals