Home
USER`S MANUAL
Contents
1. Specifications Computer Connections 2 Port Selection Push Button Switch LEDs 2 Selected Auto Scan USB Type A 4 Mouse Keyboard amp USB Peripheral USB Type B 2 PC USB Ports Connectors Video 1 x HDB 15 female std VGA SVGA Console 2 x HDB 15 male std VGA SVGA CPU Ports Power 1 x DC 5V Jack Power Consumption DC 5V 11mA max Scan Interval 5 seconds Operating Temperature 5 40 C Storage Temperature 20 60 C Humidity 0 80 RH Noncondensing Enclosure Plastic Weight 150g Dimensions L x W x H 67 x 120 x 44mm a
2. residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation Limited Warranty IN NO EVENT SHALL THE DIRECT VENDOR S LIABILITY FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THE PRODUCT DISK OR ITS DOCUMENTATION EXCEED THE PRICE PAID FOR THE PRODUCT The direct vendor makes no warranty or representation expressed implied or statutory with respect to the contents or use of this documentation and especially disclaims its quality performance merchantability or fitness for any particular purpose The direct vendor also reserves the right to revise or update the device or documentation without obligation to notify any individual or entity of such revisions or updates For further inquires please contact your direct vendor Note 1 For PC users Mac users do not have to do this since you are using a USB Keyboard and or Mouse make the following changes to your CMOS Setup program see the on screen instructions at bootup for how to enter the CMOS Setup program a In STANDARD CMOS set HALT ON ERROR to ALL BUT KEYBOARD b In PNP AND PCI SETUP set PNP OS INSTALLED to YES set USB IRQ to ENABLED 2 The drivers for most USB devices
3. CCD Cameras Scanners Printers e g are required to be shut down before you disconnect the device or else the system may crash When you switch computers with the Port Selection Switch it is the equivalent of disconnecting the device Therefore if you have USB peripheral devices other than a second keyboard and mouse connected to these ports you must be sure to shut down the USB drivers for them before switching computers Introduction Front View 1 Port Selection Auto Scan Switch The Port Selection Auto Scan switch is a pushbutton that toggles access back and forth between the computers The Selected LED on the front panel lights to indicate which port is selected The switch is also used to activate deactivate Auto Scan Mode Holding this switch down for 2 seconds activates Auto Scan Mode pressing the switch while Auto Scan Mode is active turns Auto Scan Mode Off 2 Port LEDs Asteady lights indicates that the corresponding port is the currently selected one A flashing light indicates that the corresponding port is being accessed under Auto Scan Mode 3 USB Ports The Console Mouse and Keyboard as well as any USB peripheral devices you wish to attach canplug in here The equipment can plug into any available port Zn 5 Auto Scan Mode When invoked the Auto Scan feature automatically switches between the two computers at regular 5 seconds inter
4. CCD Cameras Scanners Printers e g are required to be shut down before you disconnect the device or else the system may crash When you switch computers with the Port Selection Switch it is the equivalent of disconnecting the device Therefore if you have peripheral devices other than a second keyboard and mouse connected to these ports you must be sure to shut down the USB drivers for them before switching computers 3 CPU Port Section Cables that link the CS 102U to the computers plug in here See the Installation section for details 4 Power Jack If you choose to connect an external DC 5V Power Adapter its power cable plugs in here n Appendix Troubleshooting Note If you are experiencing problems first make sure that there are no problems with the cables and that they are all properly connected Symptom Action Keyboard Not Loose cables Check all keyboard cable connections to Responding make sure they are completely seated in their sockets Keyboard needs to be Unplug the keyboard from the Console reset Keyboard Port then plug it back in Master View needs to Turn off the computers and the Master View be reset CS 102U Wait five seconds turn the Master View unit on then turn the computers on Press the Auto Scan Switch located on the unit s top panel to exit Auto Scan Mode Mouse Not Master View is in Auto Check all mouse cable connections to make Detected or Does Scan Mode sur
5. KVM switch the CS 102U allows access to two computer systems from a single console keyboard mouse and monitor utilizing the USB connection for the console s keyboard and mouse At the same time it allows the two PCs and or Macs to utilize the USB port connection to access two USB peripheral devices printers scanners modems etc on a one computer at a time basis Installation and operation are as easy as can be Simply connect the cables The computers recognize the USB peripherals the first time they come in contact with them and automatically install the necessary drivers There is no other software installation necessary You select the active computer by simply pressing an electronic push button switch on the unit s front panel Before the development of the Master View the only way to control multiple computer configurations from a single console was through a complex and costly network system Now with the Master View CS 102U you can easily access up to two computers and two USB peripheral devices in a cost effective manner zh 27 Rear View 2 3 4 1 Console Video Connector The monitor s video cable plugs in here 2 USB Ports The Console Mouse and Keyboard as well as any USB peripheral devices you wish to attach canplug in here The equipment can plug into any available port Note The drivers for most USB devices
6. USER S MANUAL CSO Please read this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the CS 102U and or any devices it connects to This package contains 1 CS 102U KVM Switch 1 User Manual 2 USB VGA Cables If anything is damaged or missing contact your dealer Copyright 1999 ATEN International Co Ltd Manual Part NO PAPE 1163 100 Printed in Taiwan 12 1999 All brand names and trademarks are the registered property of their respective owners System Requirements Console e One VGA SVGA or Multisync monitor capable of the highest resolution that you will be using on any computer in the installation e One USB Mouse e One USB Keyboard Computer The following equipment must be installed on each computer that is to be connected to the system e Windows 98 or Mac OS 8 6 e USB Host Controller installed on the system e A VGA SVGA or Multisyne card Note Mac G3 and G4 systems have HDB 15 VGA connectors just like PCs do For other Mac systems a DB 15 to HDB 15 VGA adapter Part No 2A 806 purchased separately is required 5 Power on all devices Note 1 The CS 102U s Power On default is to link to Port 1 If the computer attached to Port 1 is inactive the monitor will be blank so it may appear as if the unit is not functioning This is not the case Simply press the Port Selection Switch located on the unit s top panel to sw
7. e they are completely seated in their Not Respond sockets Correctly Loose cables Unplug the mouse from the Console Mouse Port then plug it back in Mouse needs to be Turn off the computers if you are using a power reset adapter unplug it Wait five seconds If you are using a power adapter plug it in turn the computers on Master View needs to The Master View CS 102U supports VGA SVGA Multisync and XGA interlaced with resolutions of up to 1920x1440 The maximum bandwidth is 150 MHz be reset Video Problems Resolution and or We strongly recommend that you use high Bandwidth set too high quality cables Using high quality cables should eliminate possible video problems Cable quality not good High quality cables are optionally provided enough with some CS 102U packages otherwise see your dealer to purchase them There is no better way to save time and money than with a Master View CS 102U installation By allowing a single console to manage both of the attached computers and USB peripherals the Master View CS 102U eliminates the expense of purchasing separate keyboards monitors mice and peripherals for each system Moreover it saves all the extra space they would take up and eliminates the inconvenience and wasted effort involved in constantly having to move from one computer to the other Features Dual Function KVM USB Switch Two Switches In One Controls 2 Computers Fro
8. itch to the active computer port 2 When you start PC2 and the switch is on CPU1 the computer s bootup routine will not autodetect the monitor s capability Under such circumstances the PC reverts to VGA mode If this occurs switch to CPU2 then use Control Panel to reset the resolution 3 The Mac s keyboard Power On function is not supported You must start the Mac with its Power On switch Operation Manual Port Selection Controlling the computers in your Master View CS 102U installation from a single console could not be easier Simply press the Port Selection push button on the Master View s top panel to switch access back and forth between the computers Note The drivers for most USB devices CCD Cameras Scanners Printers e g are required to be shut down before you disconnect the device or else the system may crash When you switch computers with the Port Selection Switch it is the equivalent of disconnecting the device Therefore if you have peripheral devices other than a second keyboard and mouse connected to the CS 102U s USB peripheral ports you must be sure to shut down the USB drivers for them before switching computers a 3 Radio amp TV Interference Statement WARNING This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a
9. m a Single Console Over a USB Connection Using Standard USB Cables Simultaneous Reverse Operation 2 Computers Can Share 2 USB Peripheral Devices Eliminates Driver Conflict Between the Console s Mouse and the Computers Configuration Notebooks Can Use the Console s Mouse and Keyboard At the Same Time Easy to Install No Software Required Standard Cables to Connect to the Computers Is All It Takes Easy to Operate Computer Selection Via Push Button Switch Auto Scan Function to Monitor Computer Operation LED Display For Easy Status Monitoring Saves Time Space Power and Equipment Costs Supports DDC DDC2 DDC2B Hot Pluggable an Installation Before you begin make sure that power to all the devices you will be connecting up have been turned off 1 Plug the monitor keyboard and mouse into the Console port connectors of the Master View CS 102U unit 2 Use the video extender cables to connect the CS 102U s video ports to the video ports on the corresponding computers as shown in the diagram below 3 Use standard USB cables to connect from the CS 102U s USB ports B connectors to the USB ports on the corresponding computers A connectors as shown in the diagram below 4 If you choose to use an external 5V power adapter plug the adapter into an AC source then plug the adapter cable into the unit s Power Jack
10. vals so that you can monitor their activity without having to take the trouble of switching yourself e To invoke simply hold down the Port Selection push button switch for two seconds The Port LEDs flash when Auto Scan Mode is in effect e To turn Auto Scan Mode Off simply press and release the Port Selection push button The LEDs stop flashing when Auto Scan Mode is no longer in effect Note 1 While Auto Scan Mode is in effect neither the keyboard nor the mouse will function You must turn off Auto Scan Mode in order to be able to use the console 2 The drivers for most USB devices CCD Cameras Scanners Printers e g are required to be shut down before you disconnect the device or else the system may crash When the computers switch under Auto Scan Mode it is the equivalent of disconnecting the device Therefore if you have peripheral devices other than a second keyboard and mouse connected to the CS 102U s USB peripheral ports you must be sure that the USB drivers for them are shut down on both comuters before invoking Auto Scan Mode mn l Overview The Master View CS 102U represents a revolutionary new direction in KVM Switches a dual function 2 Port KVM Switch plus 2 Port USB Hub control unit The CS 102U incorporates USB technology to handle the data connection between itself and the connected computers and to provide two USB ports for peripheral devices that the connected computers can share As a
Download Pdf Manuals
Related Search
Related Contents
Husqvarna 560sr Lawn Mower User Manual ABS Agency Builder 3® User Manual SERVICE MANUAL - Shark Pressure Washers HP Chromebook 14-q052na AGORA - Actes de la journée d`études du 17 octobre 2005 WH-M975 - Shimano board-pc dreamGEAR DG3DS-4233 stylus pen N600 Wireless Dual Band Gigabit Router WNDR3700v4 User Manual 1 TORNADO INDUSTRIES, LLC 333 CHARLES COURT WEST Copyright © All rights reserved.