1. for IR Illuminator brightness LIGHT INTENSIFIER TUBE BRIGHTNESS ADJUSTMENT The green diode B represents light intensifier tube power ratio Once this is lit you can adjust the brightness of the light intensifier with the and adjustment buttons NOTE The Aries 258 is a GEN 1 Night Vision device adjustments Involving the light intensifier tube will be subtle due to the nature of the design Adjusting the tube s power down will take longer to take effect than adjusting it up You may notice a persistent green glow after the unit has been turned OFF don t keep pressing the key this too is due to the nature of the design a GEN 1 light intensifier tube s power supply RETICLE BRIGHTNESS ADJUSTMENT By pressing the SL button again you will see a yellow diode light up next to the green one The yellow diode represents the reticle s brightness Adjustments should be easily seen if you look through the Aries 258 while you work the and adjustment buttons To adust the brightness of the reticle or to turn It off all together use the buttons located on the control box on the side of the unit press and hold one of the or adjustment buttons while the yellow diode is lit and looking through the scope to see the change in brightness When desired brightness is reached release the button INFRA RED ILLUMINATION By pressing the SL button a third time y
2. 1 Slightly loosen horizontal and vertical fixator screws on the dove tail clamps allowing the clamps to slide on the rail 2 Place the scope on dovetail mount making certain that the mount aligns with the receptor attachment screw groove Adjust as necessary 3 Tighten horizontal fixator screws 4 Remove the Aries scope entire mounting mechanism Tighten vertical fixator screws and horizontal fixator screws 5 Remount Aries 258 and tighten receptor attachment screws NOTE Receptor attachment screws may need to be tightened after continues shooting F ar EX ipo ee Screws WINDAGE AND ELEVATION The vertical and horizontal adjustments for the Aries 258 can be achieved by turning the eleva tion and windage adjustment mechanisms Each click equal 5 inch at 100 yards NOTE When reaching the maximum of the rotation do not use force Elevation USING THE CAMERA ADAPTER coptionat To use your Aries Mk 258 with a 35mm camera or camcorder you will need the following 1 If you plan to use a camcorder then your camcorder must have a MACRO feature Most modern camcorders today have a MACRO feature built in 2 If you plan to use a 35mm camera you will need a MACRO lens If you don t have one we advise that you contact your local camera store 3 You may or may not need a STEP UP or STEP DOWN ring in order to adapt the camera adapter to your lens NOTE The camera adapter come
3. back on press SL and at the same time again NOTE The scope will be capable of running on SLEEP mode for more than 10 ten days and will be ready to use at any moment Remember you don t have to turn the unit off while you are using it Smart sight will remember all the settings Use master ON OFF switch only to store the scope The proximity sensor will work best in a dark environment Daylight testing and or 3 other situations with strong lighting may result in a temporary decrease of the proximity sensor s performance LOW BATTERY INDICATOR A Low battery indicator is another feature that is programmed into your Smart scope If the bat teries start losing voltage Led will start to pulse It Is time to change your batteries Led Led R Led B FOCUSING To focus the Aries 258 first you will need to adjust the diopter Simply turn the diopter clock wise until it stops Then while looking through the diopter at a subject slowly turn the diopter back counter clockwise until the grain in the image is sharp NOTE We suggest that you focus the diopter during daylight with the filter on Next focus the front lens until the image and the grain are both sharp When you are in low light conditions and the daylight filter is off you may focus the front lens to receive a sharp image the diopter should not be adjusted NOTE The front lens should be rea
4. compartment The 100M infra red illuminator is located on the opposite side from the battery compartment The objective lens protective cover is designed to protect the lens from scratches and abra sions This cover also protects the image intensifier tube from exposure to daylight or other bright light sources The protective cover acts as a daylight filter note the pinhole in the center of the lens cap NOTE Please refrain from testing in the daylight for more than ten 10 minutes at a time MASTER POWER SWITCH The master on off switch is to be found on the back of the unit Once the scope s master power switch is turned to the ON position you will then be able to adjust the scope from the control box CONTROL PANEL The Cluster of three buttons on the side of the Aries 258 are your controls for the unit The button acts as a three way selection toggle By pressing it once you will see one of three colored diodes located on the rear side of the control box light up Make sure to keep both eyes open and we suggest that you use your right eye for aiming through the scope This will give you a HUD Heads Up Display of the scope s functions while using the scope The and adjustment buttons increase and decrease the level of a particular function The three colored led diodes represent the mode of function of the scope B for Brightness of the light intensifier tube R for Reticle brightness and I
5. settings we mean only the digital settings These include bright ness of the tube brightness of the reticle and magnitude of the IR The sleep mode works in the following way The scope will automatically shut down if it dose not sense any activity for 20 minutes Activity includes pressing any of the buttons ir simply moving it back and forth away from your face When activating the sleep mode the scope will first warn you by turning off the reticle for 10 seconds If your intention is to keep using the scope simply touch any key and the scope will reactivate One of the reason why a SLEEP mode is programmed into your scope is to preserve the life of light intensifier tube and batteries in case you forget to turn your unit off If you notice that the reticle has turned off after 20 minutes just push SL button and the scope will return to its previous settings button button If you would like to put your scope in the SLEEP mode before the 20 minute period just push the 51 and at the same time Just push 51 to return to previous settings the Smart scope will remember them This will be a very valuable feature if you are waiting for game to come you could prepare all of the settings place the unit in SLEEP mode and activate it precisely when you need it To disable the proximity sensor press SL and at the same time In order to turn the proximity sensor
6. spots on screen S These are cosmetic blemishes in the intenslfler tube They are a by product of the process of manufacturing night vision tubes They will not impede your viewing ability Q Image not clear S Adjust focus ring If problem persists increase viewing distance FEATURES Digital Smart technology Total darkness technology e Automatic brightness control e Built in 100m IR illuminator e Internally adjustable lit reticle for windage and elevation Mounts to standard U S weaver Recoil amp flash resistant intensifier tube e Auto Sleep mode e Video 35mm camera adaptable Superb multi coated 6 element lens system e Manufactured exclusively by Two year warranty SPECIFICATIONS WMAGMINGCATION 4 0 Intensifier Tube First gen hight res Lens 6 elements 90mm F1 2 Field Of ViOW 15 FOS OUI 40 Maximum tube gain 35 000x Range of 6 6 2 to co Power Two 3 batteries Battery Life 20 hourd of continuous use Operating 40 F to 110 F 240mm x 85mm x 100mm cas aessnanaetncetucencadeunspastinecenesassens 2 3 Ibs 2 YEAR PRODU
7. Aries Mk 258 _ 7 user s guide AMERICAN TECHNOLOGIES NETWORK CORP AD Infra red illuminator Control panel Battery button housing button Mounts to standard button Internal windage US weaver rail and elevation Proximity sensor Infra red illuminator brightness adjustment light indicator 1 Reticle brightness adjustment light indicator R Light intensifier brightness light indicator B Camera adapter Master power switch The information in this manual furnished for information use only is subject to change without notice is not to be construed as acommitment by ATN Corp ATN Corp assumes no responsibility or liability for any errors or inaccuracies that may appear in this book 2001 ATN Corp All right reserved APPLICATION The Aries 258 night vision weapon scope is a complex computerized system for the observa tion of objects at low light levels less than 1 0 lux Containing an on board computer these scopes are some of the most advanced night vision weapon scopes in the world The Aries 258 consists of the objective lens assembly ocular lens assembly and the body The body contains the image intensifier tube assembly with the integrated high voltage power source The body also houses the electronics for the reticle the computer console for the Smart Technology as well as the battery
8. CT WARRANTY This product is guaranteed to be free from manufacturing defects in material and workmanship under normal use for a period of 2 two years from the date of purchase In the event a defect that is covered by the foregoing warranty occurs during the applicable period stated above ATN at its option will either repair or replace the product and such action on the part of ATN shall be the full extent of ATN s liability the Customer s sole and exclusive remedy This warranty does cover a product a used in other than its normal and customary manner b subjected to misuse subjected to alterations modifications or repairs by the Customer of by any party other than without prior written consent of d special order or close out merchandise or merchandise sold as is by either or the dealer merchandise that has been discontinued by the manufacturer and either parts or replacement units are not available due to reasons beyond the control of ATN shall be responsible for any defects or damage that in ATN s opinion isa result from the mishandling abuse misuse improper storage or improper operation including use in conjunction with equipment which is electrically or mechanically incompatible with or of inferior quality to the product as well as failure to maintain the environmental conditions specified by the manufacturer CUSTOMER IS HEREBY NOTIFIED THAT O
9. PERATION OF THE EQUIPMENT DURING DAYLIGHT HOURS OR UNDER ANY EXCESSIVE LIGHT CONDITIONS MAY PERMA NENTLY DAMAGE THE INTERNAL COMPONENTS OF THE UNIT AND SAID DAMAGE WILL NOT BE COVERED UNDER THIS WARRANTY This warranty is extended only to the original purchaser Any breach of this warranty shall be waived unless the customer notifies ATN at the address noted below within the applicable warranty period The customer understands and agrees that except for the foregoing warranty no other warranties written or oral statutory expressed or implied including any implied warranty of merchantability or fitness for a particular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole respon sibility of the Customer ATN s sole undertaking is limited to providing the products and services outlined herein in accordance with the terms and conditions of this Agreement The provision of products sold and services performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any third party of legal entity outside ATN and the Customer ATN s obligations under this Agree ment extend solely
10. ce and technical support please contact American Technologies Network Corp North American Office 20 S Linden Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2001 ATN Corporation
11. djusted as you view objects at different distances CLEANING THE EYEPIECE You may need to clean the eyepiece and of the unit you have purchased from time to time in order to guarantee top performance When you receive your Aries 258 you should check for dust on the eyepiece of the unit Eyepiece is attached to the body of the unit by two small set screws By loosening the set screws you easily slide out the eyepiece section of the unit If there is resistance when you slide out the eyepiece stop and make positive that the set screws are sufficiently loosened NOTE You do not have to remove the set screws completely they are very small and easy to misplace Now with a little more effort in the same counter clockwise direction you can unscrew the eyepiece section of the scope Once the eyepiece section has been removed from your Aries scope you may now clean the dust off the glass surfaces as well as the phosphor screen of the light intensifier tube When reinserting the eyepiece into the scope make sure it is seated completely with the internal rubber bushings CAUTION Use only Photographic lens cleaning tissue on these surfaces Be careful not to scratch or smudge any of these surfaces When using compressed air to blow dust away make sure to avoid inverting the can while spraying This may cause frozen propellent to exit the can which can result in serious problems of the glass and phosphor screen MOUNTING THE ARIES 258
12. on the Aries scope with the master power switch make sure the protective lens cover is still attached to the tens e The unit will turn on automatically when you bring it to your eye a proximity emitter will send a beam out that will sense the distance to your forehead e We suggest that you use your right eye to aim through the scope Make sure to have both of your eyes open so you will be able to see the color coded LEDs with your left eye In order to assure the proper functioning of the proximity sensor make certain that the pro tective glass surface of the sensor is always clean e When the scope is first powered up the initial settings are Light intensifier tube Brightness 100 Reticle brightness 50 Illuminator brightness 100 e Observe the scene and adjust the doctor for optimal image clarity e You may now enter a dark environment or simply shut the lights off in order to darken the room Next remove the lens cap daylight filter Observe the scene and adjust the front lent for Ideal focus e Adjust the digital features as needed e The unit will turn off automatically If you move It away from your face Increase battery life the led diodes will go off after 10 seconds e You will need to focus for different distances Take your time learning about your smart scope It will take practice to properly use this device As you use this scope you will be able to improve your speed of focusing a
13. ou will then see a Infra red illuminator red diode I light up The red diode represents the 100M infra red illuminator s brightness adjustment mode Adjust ments should be easily seen if you look through the Aries 258 while you work the and adjustment buttons Infra red illuminators or IR illuminators are common to night vision The IR light greatly enhances the perform ance of the Aries 258 while remaining almost totally invis ible to the naked eye The IR illuminator on the Aries 258 is the 100M and is located near the windage and elevation adjustments In a dark environment power up the Aries scope Now find a scene and examine it without the IR on and with the IR on Note the difference in illumina tion It is important to remember that the IR illuminator is simply an infra red light source like any light source It may loose its effectiveness over a great distance You may desire a different field of coverage from the IR illuminator if so the beam is focusable By turning the lens of the IR illuminator you will change the beam width slightly NOTE will automatically turn off when the unit s main power switch is turned to the off position SLEEP MODE One of greatest new features that your Smart scope has is a SLEEP mode This feature will extend the life of your scope many folds set the scope to memorize your initial settings and extend your battery life by
14. s well as sharpness of image Have fun and enjoy WARNINGS AND CAUTIONS Always remember to turn off the Aries 258 when it is not in use If you do not plan on using your aries scope for a period of more than 10 days you should remove the batteries Keep lens cap daylight filter on when not in use Avoid contact with dust steam and gas The Aries 258 are not harmful to the user or the environment Do not disassemble except to clean the front lens and the eyepiece it will void warranty Evaluate the scopes function by looking through It In a lit environment with the day light filter cap on Do not surpass ten minutes of testing e Never point the Aries 258 at a bright light source If the scope shuts off automatically after directing it at a bright light source turn the unit off and wait 1 2 minutes before turning the unit back on Adverse atmospheric conditions such as fog smog or haze and a lack of ambient light moon or starlight may diminish the effective viewing distance All technical data for this unit was compiled in a controlled environment TROUBLE SHOOTING Q Rashes flickers or clicking occur while operating S If it occurs within the first five minutes of inserting new batteries it is normal and the device will resume normal operation soon thereafter If it occurs for more than 10 minutes contact your dealer or other authorized service representative for service instructions Q Dark
15. s with 37 mm and 52 mm threads If you need other sizes your local camera store should be able to help e Remove the rubber eye cup from the Aries Mk 258 Screw the camera adapter onto the front of the lens on your Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the camera adapter over the Aries Mk 258 s eyepiece Tighten the three set screws to fit snugly to the Aries Mk 258 eyepiece e You may need to focus the 35 mm camera or video camera in combination with the Aries Mk 258 in order to get the sharpest image possible e We suggest that you find an open space to work in Focus the Aries Mk 258 so that the scene is at its sharpest For the best results you should disable the auto focus if any on either the 35mm camera or the video camera and manually focus the 35 mm camera or the video camera Once the image is in sharp then simply adjust the Aries Mk 258 front lens to change the focus An important part to remember is that you are not taking a picture of an object that is far away from you but you are actually taking a picture of a phosphorous screen of the Aries Mk 258 that is only 2 3 inches away Joint ring PREPARATION FOR OPERATION Before getting started make sure to follow these steps e Take the scope out of the case Install the batteries into its housing with the polarity order shown on the main body of the unit Switch
16. to the Customer ATN s liability hereunder for damages regardless of the form or action shall not exceed the fees or other charges paid to ATN by the customer or customer s dealer ATN shall not in any event be liable for special indirect incidental or consequential damages including but not limited to lost income lost revenue or lost profit whether such damages were foreseeable or not at the time of purchase and whether or not such damages arise out of a breach of warranty a breach of agreement negligence Strict liability or any other theory of liability PRODUCT WARRANTY REGISTRATION In order to validate the warranty on your product ATN must receive a completed Product Warranty Registration Card for each unit Please complete the form below and immediately mail it to our Service Center ATN Corporation 20 South Linden Ave Suite 1B South San Francisco CA 94080 Products qualifying for warranty repair will be either repaired or replaced within 10 business days of receipt of merchandise unless the customer is notified otherwise OBTAINING WARRANTY SERVICE To obtain warranty service on your unit take or send the product postage paid with a copy of your sales receipt to our service center ATN Corporation at the address noted above All merchandise must be fully insured with the correct postage ATN will not be responsible for improper postage or missing or damaged merchandise during shipment 10 For customer servi