Honeywell UV100E 2009 Air Purifier
Contents
1. the 40 minutes the timer resets to 40 minutes When no airflow is detected for 40 minutes the lamp turns off until the next occurrence of airflow M22858 Fig 1 Typical Air Treatment System installations 3 69 1573 2 UV100E ULTRAVIOLET SYSTEM Surface Treatment System When installed next to the cooling coil of your system your Ultraviolet Surface Treatment System prevents a high percentage of the growth of micro organisms such as mold that may grow on duct surfaces coils and drain pans Individual results depend on careful installation and maintenance See Fig 2 Your Ultraviolet Surface Treatment System operates a steady three hours on three hours off cycle With Enviracom communication terminals hooked up your UV System turns off for the Winter 30 days after the last call for cooling occurs And your UV System turns on and resumes the on off cycle with the first call for cooling in the Spring M22860 Fig 2 Typical Surface Treatment System installations You can capture and minimize micro organisms passing through your forced air system when you combine your UV System with a high efficiency air filtration system like an electronic air cleaner Talk to your installer about adding an electronic air cleaner to complement your UV System and provide added protection for you and your family 69 1573 2 4 UV100E ULTRAVIOLET SYSTEM Enviracom Communications Capabilities Communicates wi
2. Honeywell Honeywell Proud Partner AMERICAN LUNG ASSOCIATION FIHEALTH HOUSE UV100E Ultraviolet System OWNER S GUIDE Q Q 4 e AE e e E 5 race oi e mi E o 69 1573 2 UV100E ULTRAVIOLET SYSTEM American Lung Association Health House Program and Honeywell Working Together For Better Air Did you know that the average person breathes 3400 gallons 12 870 liters of air each day and spends 90 of that day inside Indoor air quality products from Honeywell are designed to help make your home more comfortable from zoning products that allow you to control the temperature in individual areas of the home to humidifiers and comfort control centers that help balance the moisture content of your indoor air Honeywell is proud to be a partner of the American Lung Association Health House program that provides guidelines for constructing homes with improved air quality and ventilation For more information on ways to improve the air inside your home please visit the Health House website at www healthhouse org and the American Lung Association website at ww lungusa org The American Lung Association and its Health House program do not endorse products For more information about Honeywell Indoor Air Quality products visit www honeywell com yourhome or call 1 800 345 6770 x531 EPA National Air Quality 1999 Status amp Trends Indoor Air Pollution An Introduction for Health Professiona
3. a clean dry cloth 7 Insert the bulb into the base with the lamp light indicator at the eleven o clock position Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 8 M22848 Fig 8 Position bulb for insertion back into the lamp base 8 Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 9 M22850 Fig 9 Snap bulb into place 11 69 1573 2 UV100E ULTRAVIOLET SYSTEM 9 Reconnect power to your UV System 10 For UV Air Treatment Systems wait ten minutes for the airflow sensor to calibrate During this time the furnace fan must remain off NOTE Failure to wait ten minutes for the airflow sensor to calibrate before powering the system fan causes the airflow sensor to incorrectly calibrate and the device to incorrectly function If this occurs remove power to the furnace or turn off the system fan wait ten minutes and then resume normal fan operation 11 Verify that your ultraviolet bulb is operating by viewing only through the lamp light indicator on the lamp handle Never look directly at your bulb while it is illuminated 12 Reconnect power to your heating and cooling system Bulb Replacement Replacement of the bulb in your ultraviolet lamp when the LED is solidly lighted is required to maintain effectiveness 1 Obtain the correct replacement b
4. ckwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 9 Reconnect power to your UV System For UV Air Treatment Systems wait ten minutes for the airflow sensor to calibrate During this time the furnace fan must remain off NOTE Failure to wait ten minutes for the airflow sensor to calibrate before powering 11 12 13 the system fan causes the airflow sensor to incorrectly calibrate and the device to incorrectly function If this occurs remove power to the furnace or turn off the system fan wait ten minutes and then resume normal fan operation Verify that your ultraviolet bulbs are operating by viewing only through the lamp light indicator on the lamp handle Never look directly at your bulbs while illuminated Reconnect power to your heating and cooling system Press and hold the reset button for five seconds to reset the internal timers 13 69 1573 2 UV100E ULTRAVIOLET SYSTEM Five Year Limited Warranty Honeywell warrants this product excluding bulbs to be free from defects in the workmanship or materials under normal use and service for a period of five 5 years from the date of purchase by the consumer If at any time during the warranty period the product is defective or malfunctions Honeywell shall repair or replace it at Honeywell s option within a reasonable period of time If the product is defective i return it with a bill
5. ls EPA US Government Printing Office 1994 523 217 81322 IMPORTANT Please read these instructions and keep them in your records 69 1573 2 2 UV100E ULTRAVIOLET SYSTEM HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM OR SURFACE TREATMENT SYSTEM WORKS Your UV System uses patented SmartLamp control technology that monitors the HVAC system to operate the lamp only when needed This technology extends bulb life up to five times and reduces power consumption lowering operating costs Your UV System also includes protection from extreme conditions that may be found in your heating and cooling system and local diagnostics with the SmartLamp LED and reset capability Depending on installation your UV System can operate as an Air Treatment System or as a Surface Treatment System Air Treatment System Installed in the return air duct of your system your Ultraviolet Air Treatment System kills a high percentage of airborne germs circulating through your forced air heating and cooling system Individual results depend on careful installation and maintenance and on the actual amount of time your system fan operates See Fig 1 Your Ultraviolet Air Treatment System uses the on board air flow sensor or input from the Enviracom communication terminals to monitor air flowing through your heating and cooling system The UV system turns on when air is flowing and leaves the lamp on for 40 minutes after the airflow stops If airflow resumes during
6. not illuminate unless the base is mounted on your forced air system duct It is recommended that every month you verify that your ultraviolet lamp is operating View the bulb only through the lamp light indicator on the lamp handle See Fig 3 Do not attempt to look into the duct at the illuminated bulb s If the light is not on when you check your UV System briefly push the reset button for one second This brings the lamp on for 40 minutes Air Treatment System or for 30 minutes Surface Treatment System Pressing the reset button for five seconds resets all internal timers Cycling power does not reset the internal timers LAMP LIGHT INDICATOR LED CHANGE INDICATOR RESET BUTTON M22856 Fig 3 Lamp light indicator LED change indicator and reset button The LED indicator on the front of your UV System operates as follows LED Status Indicates Homeowner Action Off 100 to 11 bulb life remaining Nothing Flashing 10 to 1 bulb life remaining Purchases bulb s Solid 0 bulb life remaining Replaces bulb s Bulb life means emitting adequate amount of UV C energy to maintain an effective kill rate At 0 bulb life remaining the bulbs continue to operate until catastrophic bulb failure bulb burns out but the kill rate becomes rapidly negligible 69 1573 2 8 UV100E ULTRAVIOLET SYSTEM HOW YOU CAN MAINTAIN YOUR UV SYSTEM You should regularly clean your UV System to maintain peak effecti
7. of sale or other dated proof of purchase to the retailer from which you purchased it or ii package it carefully along with proof of purchase including date of purchase and a short description of the malfunction and mail it postage prepaid to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This war
8. ranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations Honeywell 1985 Douglas Dr N MN10 1461 Golden Valley MN 55422 In Canada write Retail Products ON15 02H Honeywell Limited Honeywell Limit e 35 Dynamic Drive Scarborough Ontario M1V429 69 1573 2 14 15 UV100E ULTRAVIOLET SYSTEM 69 1573 2 UV100E ULTRAVIOLET SYSTEM Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 yourhome honeywell com Printed in U S A on recycled O ss Honeywell U S Registered Trademark 2005 Honeywell International Inc 69 1573 2 GH Rev 04 05
9. t device in location that allows ultraviolet light to be seen after installation Do not attempt to bypass duct mount switch Do not attempt to open housing unit is sealed to prevent ultraviolet light exposure CAUTION Personal Injury Hazard Power supply can cause electrical shock Disconnect power supply before cleaning or replacing ultraviolet bulb s Do not open base unit or lamp handle there are no user serviceable components inside CAUTION Breakable Glass Hazard Can cause personal injury Be careful when inserting bulb s into lamp base Wear protective gloves when handling bulb s A A CAUTION UV Lamp Burn Hazard Harmful to bare skin Can cause severe burns Disconnect power 15 minutes before removing ultraviolet bulb s 69 1573 2 6 UV100E ULTRAVIOLET SYSTEM OR MERCURY NOTICE This device contains mercury in the sealed ultraviolet bulb s Do not place your used bulb s in the trash Dispose of properly Broken Bulb Cleanup Do not use a household vacuum Sweep debris phosphor glass into a plastic bag and dispose of properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of old bulb s 7 69 1573 2 UV100E ULTRAVIOLET SYSTEM HOW YOU CAN CHECK YOUR ULTRAVIOLET SYSTEM Your UV System is designed to prevent accidental contact with electrical voltage and with ultraviolet rays in the sealed unit the ultraviolet lamp does
10. th homeowner through three wire communication bus using 24 Vac thermostat connections Hooked up to Air Treatment System single bulb and dual bulb models uses thermostat load information instead of airflow sensor Hooked up to Surface Treatment System model uses thermostat load information to operate during times evaporator coil may be exposed to moisture to extend lamp life beyond two years Sends messages to communicate reset and receives remote reset when available Bulb change indication cannot be reset by cycling power When Enviracom is transmitting messages shows flashing green Enviracom LED on bottom of unit Other messages include percent of bulb life remaining internal faults and lamp energized Control calculates percent of lamp run time starts remaining and sends out this information through an Enviracom message When Enviracom is transceiving messages shows solid green Enviracom LED on bottom of unit 5 69 1573 2 UV100E ULTRAVIOLET SYSTEM BE SURE TO READ WARNINGS AND CAUTIONS BEFORE USING YOUR UV SYSTEM A A A WARNING UV Light Hazard Harmful to bare skin and eyes Can cause temporary or permanent loss of vision Never look at bulbs while illuminated View illumination only through light indicator located on lamp handle To prevent exposure to ultraviolet light disconnect power to Ultraviolet System before servicing any part of heating and air conditioning system Do not moun
11. ulb handle assembly or replacement bulb for your unit See Table 1 Table 1 Select a Replacement Bulb Handle Assembly or Replacement Bulb Replacement Bulb SnapLamp Unit Description Handle Assembly Replacement Bulb UV100E1043 UC100E 1006 UC18W Air Treatment System UV100E2009 UC100E1014 UC36W Air Treatment System twin pack two needed UV100E3007 UC100E1030 UC36W Surface Treatment System 2 Disconnect the power to your heating and cooling system 3 Unplug or turn off power to your UV System and allow the bulb to cool for at least 15 minutes 4 Rotate the lamp handle counterclockwise and gently pull the lamp handle to remove the bulb See Fig 5 69 1573 2 12 5 6 10 UV100E ULTRAVIOLET SYSTEM If you have a SnapLamp handle follow steps 5 and 6 otherwise proceed to step 7 Grasp the SnapLamp handle in one hand and the lamp glass in the other and pull straight apart See Fig 10 M22852 Fig 10 Disconnect lamp glass from SnapLamp handle Insert the new lamp glass into the SnapLamp handle by aligning the key and pushing straight together See Fig 11 lt di T Qu M22854 Fig 11 Replace lamp glass in SnapLamp handle Insert the bulb into the base with the lamp light indicator at the eleven o clock position Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 8 Rotate the lamp clo
12. veness of your air treatment or surface treatment system Replace the ultraviolet bulb when LED status light on the front of your UV System is on steadily Quarterly Bulb Cleaning Bulb cleaning is recommended as routine maintenance four times a year or every three months Use the UV Bulb Cleaning Reminder Schedule Fig 4 to help establish and track your regular cleaning schedule UV BULB CLEANING REMINDER SCHEDULE INSTALLATION DATE month year YEAR J F M A M J J A S O N D M13516A Fig 4 UV bulb cleaning reminder schedule To clean your bulbs 1 Disconnect the power to your heating and cooling system 2 Unplug or turn off power to your UV System and allow the bulb to cool for at least 15 minutes 9 69 1573 2 UV100E ULTRAVIOLET SYSTEM 3 Rotate your lamp handle counterclockwise and gently pull the lamp handle to remove the bulb See Fig 5 M22842 Fig 5 Remove lamp bulb 4 Holding the lamp handle wipe the lamp glass using a soft cloth dampened with glass cleaner If you touch the lamp glass with your hands be sure to clean the area of any oils left from bare hands See Fig 6 Fig 6 Clean glass with soft cloth 5 Also wipe away any dust that may have collected between the lamp light indicator base and the black bulb base See Fig 7 LAMP LIGHT INDICATOR BASE M22846 Fig 7 Wipe lamp light indicator base 69 1573 2 10 UV100E ULTRAVIOLET SYSTEM 6 Dry bulb with
Download Pdf Manuals