Home

Broan-NuTone N-RF68HRPSC Attic Fan Attic Fan

image

Contents

1. NU IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer B Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION This unit has an unguarded impeller Do not use in locations readily accessible to people or animals WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code a
2. aviser NuTone l adresse fournie ci dessous ou par t l phone au 1 800 543 3687 b fournir le num ro du mod le et la description de la pi ce et c d crire la nature du d faut de la piece ou du produit Au moment de la demande de service sous garantie vous devez fournir une preuve de la date d achat originale Date d installation N de mod le et description du produit Entrepreneur ou installateur POUR OBTENIR DE L ASSISTANCE OU DU SERVICE Pour connaitre le Centre de service NuTone autoris ind pendant le plus proche R sidents des Etats Unis continentaux composez le num ro sans frais 1 800 543 8687 Garder a prot e de la main le num ro du mod le la date et la preuve d achat le type de probleme R sidents de l Alaska et d Hawaii crivez NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio USA 45227 1599 R sidents du Canada Ecrivez Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 Les caract ristiques de produits peuvent changer san pr vis 4820 Red Bank Road Cincinnati OH 45227 Imprim aux E U Nu LEA Y GUARDE ESTAS INSTRUCCIONES INSTRUCCIONES DE INSTALACION Ventilador el ctrico para el desv n MODELO RF 69NR RF 68HRPSC INSTRUCCIONES IMPORTANTES DE SEGURIDAD ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO SACUDIDA ELECTRICA O LESIONES A LAS PERSONAS OBSERVE LO SIGUIENTE A Use
3. Asociaci n Norteamericana para los Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado ASHRAE por sus siglas en ingl s y de las autoridades del c digo local C Cuando corte o taladre en una pared o techo no da e el cableado el ctrico ni otros servicios p blicos escondidos D Los ventiladores entubados siempre deben de estar ventilados hacia el exterior E Si esta unidad se va a instalar sobre una ba era o ducha debe estar marcada como apropiada para la aplicaci n F No instale NUNCA un interruptor donde pueda ser alcanzado desde una ba era o ducha IMPORTANTE Por cada 8 5 m3 300 CFM de rendimiento del ventilador es necesario un m nimo de 09 m2 1 pie cuadrado de espacio de admisi n en un tico o s tano de peque a altura para tener un funcionamiento correcto Las reas de admisi n deben estar ubicadas lo m s lejos posible de la ubicaci n del ventilador como en un alero o en las paredes laterales CABLE NEGRO DESDE EL MOTOR MONTAJE DEL VENTILADOR IMPORTANTE Si se va a montar el ventilador en un tejado plano haga un bordillo para montar el ventilador el ventilador debe estar sobre el nivel de la red de distribuci n del agua del tejado 1 Determine la ubicaci n del ventilador en el centro del tico cerca del pico del tejado En la ubicaci n deseada haga un agujero a trav s del tejado centrado entre los cabios 2 Usando el agujero taladrado como centro dibuje un c rculo d
4. Y EXCLUSIVO RECURSO QUE TENDR EL COMPRADOR BAJO ESTA GARANTIA NUTONE NO SERA RESPONSABLE POR DANOS INCIDENTALES CONSECUENTES O ESPECIALES QUE RESULTEN A CONSECUENCIA O SEAN INDEPENDIENTE DEL USO O DESEMPE O DEL PRODUCTO Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada pueda que no se aplique a Ud Esta garant a le proporciona derechos legales espec ficos y Ud puede tener otros derechos los cuales var an de estado a estado Esta garant a reemplaza a todas las garant as anteriores SERVICIO DE GARANT A Para tener derecho al servicio de garant a Ud debe a Notificar a NuTone a la direcci n indicada m s abajo o al tel fono 1 800 543 8687 b indicar el n mero de modelo y la identificaci n de la parte y c describir la naturaleza de cualquier defecto en el producto o parte Al momento de solicitar el servicio por la garant a Ud debe presentar la evidencia de la fecha original de compra Fecha de instalaci n Constructor o instalado N de modelo y descripci n del producto SI NECESITA ASISTENCIA O SERIVIVIO Para obtener la localizaci n del Centro de Servicio Autorizado Los residentes de los Estados Unidos contiguos llam gratis al 1 800 543 8687 Por favor est preparado para suministrar Fecha y prueba de compra La naturaleza de la dificultad Los residentes de Alaska o Hawaii deben escribir a NuTone Inc Attn Departm
5. couvre pas a l entretien et le service courants ni b les produits et les pi ces ayant fait l objet d un usage abusif de n gligence d un accident d un entretien ou d une r paration non appropri e par du personnel non autoris par NuTone d une mauvaise installation ou d une installation non conforme aux directives d installation fournies La dur e de toute garantie implicite est limit e la p riode de deux ans pr cis e pour la garantie expresse Certains tats ne reconnaissent pas les restrictions relatives la dur e des garanties implicites il se pourrait donc que cette restriction ne s applique pas dans votre cas LE REMPLACEMENT OU LA R PARATION PAR NUTONE SA PROPRE DISCRETION DE TOUT PRODUIT OU PIECE DEFECTUEUX CONSTITUE LE SEUL REMEDE DE L ACHETEUR EN VERTU DE CETTE GARANTIE NUTONE NE PEUT ETRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONSECUTIFS OU SPECIAUX ATTRIBUABLES A L UTILISATION OU AU RENDEMENT DU PRODUIT Certains tats ne reconnaissent pas les restrictions ni les exclusions relatives aux dommages indirects cons cutifs ou sp ciaux il se pourrait donc que cette restriction ne s applique pas dans votre cas La pr sente garantie vous accorde des droits sp cifiques mais vous pourriez aussi avoir d autres droits en fonction de l tat dans lequel vous r sidez Cette garantie remplace toute autre garantie donn e pr c demment SERVICE SOUS GARANTIE Pour tre admissible au service sous garantie vous devez a
6. esta unidad solamente de la manera prevista por el fabricante Si tiene preguntas comun quese con el fabricante B Antes de dar servicio a la unidad o de limpiarla apague la corriente en el panel de servicio y ci rrelo con llave paraevitar que enciendan la corriente accidentalmente Cuando no se puedan cerrar con llave los medios de desconexi n del servicio coloque un aviso de advertencia bien visible en el panel de servicio como por ejemplo una etiqueta PRECAUCION Solamente para uso de ventilaci n general No lo use para expulsar materiales y vapores peligrosos o explosivos PRECAUCION Esta unidad tiene un pist n impulsor sin protecci n No lo use en ubicaciones que sean accesibles a personas o animales ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO SACUDIDA ELECTRICA O LESIONES A LAS PERSONAS OBSERVE LO SIGUIENTE A El trabajo de instalaci n y el cableado el ctrico deben ser realizados por una persona cualificada seg n todos los c digos y normas aplicables incluida la construcci n clasificada para el fuego B Se necesita aire suficiente para la combusti n correcta y el escape de gases a trav s del conducto de humos de la chimenea del equipo quemador de combustible para evitar la contracorriente Siga las normas de seguridad y las directrices del fabricante del equipo de calefacci n as como las publicadas por la Asociaci n Nacional de Protecci n contra Incendios NFPA por sus siglas en ingl s y por la
7. model number Date and Proof of purchase The nature of the difficulty Residents of Alaska or Hawaii should write to NuTone Inc Attn Department of National Field Service 4820 Red Bank Road Cincinnati Ohio 45227 1599 Residents of Canada should write to Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 Product specifications subject to change without notice 4820 Red Bank Road Cincinnati OH 45227 Printed in U S A Rev 7 01 Part No 88020 Nu LIRE ET CONSERVER CES DIRECTIVES DIRECTIVES D INSTALLATION Ventilateur avec moteur pour grenier MODELE RF 69NR RF 68HRPSC IMPORTANTES DIRECTIVES DE S CURIT AVERTISSEMENT POUR R DUIRE LES RISQUES D INCENDIE DE CHOCS ELECTRIQUES OU DE BLESSURES RESPECTEZ CE QUI SUIT A Utilisez cet appareil seulement pour les usages pr vus par lefabricant Pour toute question communiquez avec le fabricant B Avant de faire l entretien ou le nettoyage de l appareil coupez l alimentation au panneau de distribution lectrique et verrouillez ce dernier pour eviter la remise accidentelle du courant S il est impossible de verrouiller le dispositif coupe courant apposez y une mise en garde visible une etiquette par exemple ATTENTION Pour ventilation generale seulement N utilisez pas ce ventilateur pour evacuer des vapeurs ou des matiares explosives ou dangereuses ATTENTION Cet appareil est dot d une h l
8. o GARANT A DEL PROPIETARIO NuTone garantiza al comprador consumidor original de sus productos por el per odo de un 1 a o desde la fecha original de compra que tales productos est n libres de defectos en material y mano de obra NO HAY OTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO PERO NO LIMITADAS A GARANT AS NO EXPRESADAS DE MERCANTIBILIDAD O ADAPTABLES A UN PROP SITO EN PARTICULAR Durante este per odo de un a o NuTone reparar o reemplazar a su opci n y sin costo cualquier producto o parte que se encuentre defectuoso bajo condiciones normales de uso y servicio ESTA GARANT A NO CUBRE A LOS ARRANCADORES PARA L MPARAS FLUORESCENTES O A LOS TUBOS FLUORESCENTES FILTROS DUCTOS TAPAS DE TECHO TAPAS DE PARED Y OTROS ACCESORIOS PARA CANALIZACI N Esta garant a no cubre a Mantenimiento y servicios normales b Productos o partes sujetos al mal uso negligencia accidente mantenimiento inadecuado o reparaciones por otros ajenos a NuTone instalaci n defectuosa o a una instalaci n contraria a las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a no expresada est limitada a un per odo de un a o seg n se especifica en la garant a expresada Algunos estados no permiten limitaci n en cuanto a la duraci n de una garant a no expresada por lo que la limitaci n arriba indicada puede que no se aplique a Ud LA OBLIGACI N DE NUTONE DE REPARAR O REEMPLAZAR A SU OPCI N SER EL NICO
9. OTEUR N FIL D ALIMENTATION DOMESTIQUE FILS DU MOTEUR DU VENTILATEUR FILS BLANCS DU Y MOTEUR ET D ALIMENTATION INSTALLATION DE LA BOITE LECTRIQUE DU THERMOSTAT IMPORTANT N installez pas la bo te pr s d une source de chaleur 1 Installez la bo te lectrique sur un ferme de toit de fa on que la bo te soit plac e plus haut que le moteur du ventilateur R GLAGE DU THERMOSTAT Le thermostat du ventilateur est r gl 43 C Le ventilateur se d clenche automatiquement lorsque la temp rature ambiante atteint ce niveau puis s arrate lorsque la temperature descend 10 degres sous la temperature fixee La temperature de d clenchement peut atre r gl e entre 21 et 54 C ENTRETIEN ATTENTION Avant de faire le nettoyage ou l entretien de l appareil assurez vous que le courant est coup au tableau de distribution Consultez les importantes directives de s curit de la page 1 Au debut de chaque saison de ventilation assurez vous qu aucun debris ne fait obstacle au fonctionnement du ventilateur nin bouche la grille ou les orifices d aeration du moteur Pour prolonger la dur e de vie utile du moteur lubrifiez le au debut de chaque saison de ventilation Les orifices de U lubrification sont situ s sur le devant et sur l arri re du moteur Appliquez de 5 a 6 gouttes d huile moteur 20 W sans d tergent dans chaque orifice C BLAGE ATTENTION Assurez vous que le ventilateur et inte
10. e 36 83 cm de di metro en el tejado Para dibujar el c rculo se puede hacer un compts con un trozo de madera y dos puntas colocadas a 18 42 cm de separaci n 3 Haga el recorte en el tejado a lo largo del c rculo que se haya dibujado Si el tejado tiene tejamaniles corte los tejamaniles a lo largo del c rculo usando tijeras de hojalatero una navaja etc 4 Ponga el ventilador sobre el agujero del tejado Clave el reborde de montaje en el tejado con puntas Ponga calafateo alrededor del reborde de montaje para evitar la infiltraci n de agua Si el tejado tiene tejamaniles deslice el reborde de montaje debajo de los tejamaniles circundantes MONTAJE DE LA CAJA DE SALIDA DEL TERMOSTATO IMPORTANTE No monte la caja de salida cerca de una fuente de calor 1 Monte la caja de salida en un cabio cercano para que quede m s alta que el motor del ventilador CABLE NEGRO AL SUMINISTRO ELECTRICO DE LA VIVIENDA CABLEADO DEL SUMINISTRO EL CTRICO DE LA VIVIENDA S CABLEADO DEL MOTOR DEL VENTILADOR CABLES BLANCOS DESDE LA FUENTE FE ALIMENTACiON DEL MOTOR Y LA VIVIENDA AJUSTE DEL TERMOSTATO El termostato del ventilador esta preajustado a 43 C El ventilador se enciende automaticamente cuando la temperatura ambiente alcanza ese nivel y se para cuando la temperatura baja 10 grados por debajo de la temperatura fijada La temperatura de encendido puede ser ajustada de 21 a 54 C MANTENIMIENTO PRECAUCION Antes de lim
11. ent of National Field Service 4820 Red Bank Road Cincinnati Ohio USA 45227 1599 Los residentes de Canada crivez Broan NuTone Canada 1140 Tristar Drive Mississauga Ontario Canada L5T 1H9 Rev 03 2001 Las especificaciones del producto est n sujetas a cambio sin previo aviso 4820 Red Bank Road Cincinnati Ohio 45227 Impreso en los EE UU PARTS LIST ORIGINAL i PART NO 67174 67547 PART DESCRIPTION BIRD GUARD BIRD GUARD MOTOR MOTOR CAPACITOR 7 5uf RF 68HRPSC RF 69NR BLADE BLADE 86898 COVER COVER THERMOSTAT RF 69NR RF 68HRPSC NuTone 87409 CONDUIT RF 69NR RF 68HRPSC MOTOR MOUNTING BRACKET RF 69NR RF 68HRPSC Attn Parts Department 4820 Red Bank Road Cincinnati OH 45227 1599 Phone 513 527 5426 Fax 513 527 5173 EFFECTIVE PRODUCT DATE MODEL NUMBER GROUP RF 69NR REV RF 68HRPSC JULY 2001 CURRENT REPLACEMENT PART NO 67174 000 67547 000 87439 000 87405 000 0419B 000 87401 000 87402 000 87409 000 86898 000 87184 000 67552 000 68643 000 MODEL USED ON RF 69NR RF 68HRPSC RF 69NR RF 68HRPSC NOTE Always order by current part number RF 69NR L I
12. ice sans protecteur Evitez de l installer a un endroit facilement accessible notamment par les enfants ou les animaux AVERTISSEMENT POUR REDUIRE LES RISQUES D INCENDIE DE CHOCS LECTRIQUES OU DE BLESSURES RESPECTEZ CE QUI SUIT A Les travaux d installation et de mise en place des fils lectriques doivent atre confi s a une personne qualifi e conformement aux codes et aux normes en vigueur y compris les normes relatives a la prevention des incendies B Pour eviter les retours d air les appareils de chauffage qui consomment du carburant ont besoin de suffisamment d air pour assurer la combustion appropri e du carburant et l vacuation des gaz par la chemin e Suivez les directives du fabricant de l quipement de chauffage ainsi que les normes de s curit notamment celles publi es par la National Fire Protection Association NFPA par l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE ainsi que les codes locaux en vigueur C Lorsque vous percez des ouvertures ou des orifices dans les murs et les plafonds evitez d endommager les fils electriques et tout autre conduit cache D Les ventilateurs avec conduits doivent toujours atre reli s l ext rieur E Si l appareil doit atre install au dessus d un bain ou d une douche il doit porter une tiquette sp cifiant qu il est conforme une telle application F Ne placez JAMAIS un interrupteur la port e d une perso
13. nd mounting flange to help prevent water seepage If the roof is shingled slide mounting flange under the surrounding shingles MOUNTING THE THERMOSTAT S OUTLET BOX IMPORTANT Do not mount outlet box near heat source 1 Mount the outlet box to a nearby rafter so that the outlet box is higher than the fan motor BLACK LEAD HOUSE SUPPLY BLACK LEAD FROM MOTOR lt gt HOUSE SUPPLY WIRING SUPPLY A GROUND FAN MOTOR WIRING WHITE LEADS FROM MOTOR AND HOUSE SUPPLY ADJUSTING THE THERMOSTAT The fan thermostat is preset at 110 F The fan will automatically start when the ambient temperature reaches that level and stop when the temperature drops10 degrees below the set temperature Starting temperature can be adjusted from 70 F to 130 F MAINTENANCE CAUTION Before cleaning or servicing unit make sure power is disconnected at service panel See important safety instructions on page 1 At the beginning of each ventilating season check fan for any debris that may be blocking fan blades screen or motor ventilation openings To extend motor life lubricate motor at the beginning of each ventilating season Oil ports are located on the front and back of the motor Use 5 or 6 drops of 20W non detergent motor oil in each port U WIRING CAUTION Be sure fan and switches are properly grounded and all wiring complies to local electrical code requirements for 120vAC 15 amp circuit 1 Run 120VAC power wiring t
14. nne qui se trouverait dans le bain ou dans la douche IMPORTANT Pour un d bit de 8 5 m3 300 CFM le ventilateur a besoin d une prise d air de 0 9 m2 1 pi2 au grenier pour bien fonctionner Cette prise d air doit en outre atre situ e le plus loin possible du ventilateur par exemple sur un mur lat ral ou sur la sous face INSTALLATION DU VENTILATEUR IMPORTANT Si le ventilateur doit atre mis en place sur un toit plat fabriquez un socle pour y installer le ventilateur de fa on que ce dernier soit situ au dessus de la ligne de mont e des eaux 1 D terminez l emplacement du ventilateur au centre du grenier pres du faite du toit Percez un orifice dans le toit a l emplacement d sir centr entre les fermes de toit 2 En prenant Porifice comme centre tracez un cercle de 36 83 cm de diam tre sur le toit Pour ce faire vous pouvez fabriquer un compas au moyen d une pi ce de bois et de deux clous espac s de 18 42 cm 3 D coupez le toit le long du cercle trac Lorsque le toit est recouvert de bardeaux coupez ces derniers le long du cercle trac au moyen de ciseaux m tal ou d un couteau 4 Placez le ventilateur sur louverture pratiqu e dans le toit Clouez la solive dans le toit puis appliquez un ruban de scellant tout autour de la solive pour empacher les infiltrations d eau Lorsque le toit est recouvert de bardeaux glissez la solive sous ceux ci FIL NOIR D ALIMENTATION FIL NOIR DU M
15. o the thermostat outlet box and secure with box connector Use 14 gauge wire with ground See wiring diagram 2 It is suggested that an on off switch be installed in a convenient location in the living quarters of the house so the fan may be turned off when not needed OPTIONAL ACCESSORY Sold separately Model AHS 200 Automatic Heat Sensor will automatically shut down the Attic Fan if for any reason the temperature in the attic reaches 200 F One Year Limited Warranty WARRANTY OWNER NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES FILTERS DUCT ROOF CAPS WALL CAPS AND OTHER ACCESSORIES FOR DUCTING This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by NuTone faulty installation or installation contrary to recommended installation instructions The du
16. piar o dar servicio a la unidad asegurarse de que la corriente esta desconectada en el panel de servico Veanse las importantes instrucciones de seguridad en la pagina 1 Al comienzo de cada estaci n de ventilacion comprobar si el ventilador tiene suciedad que pueda bloquear las paletas la pantalla o las aberturas de ventilacion del motor Para extender la vida del motor lubricar el motor al comienzo de cada estaci n de ventilaci n Los orificios de paso del aceite estan ubicados en la parte delantera y trasera del motor Usar 5 0 6 gotas del lubricante para motor no detergente 20W en cada Orificio CABLEADO PRECAUCION Asegurese de que el ventilador y los interruptores est n puestos a tierra correctamente y que todo el cableado cumpla con los requisitos locales del codigo el ctrico para el circuito de 120 V CA y 15 amperios 1 Tienda el cableado de 120 V CA hasta la caja de salida del termostato y fijelo con un conector de la caja Use el cable de calibre 14 con la tierra Vea el diagrama del cableado 2 Se recomienda instalar un interruptor de encendido apagado en una ubicaci n prfctica en el area habitada de la casa para que se pueda apagar el ventilador cuando no se necesite ACCESORIO OPCIONAL Vendido separadamente El sensor de calor automatico modelo AHS 200 apagara automaticamente el ventilador de atico si por cualquier motivo la temperatura del atico alcanza los 93 C Nulone Garant a Limitada de un A
17. ration of any implied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties WARRANTY SERVICE To qualify for warranty service you must a notify NuTone at the address stated below or telephone 1 800 543 8687 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Date of Installation Builder or Installer Model No and Product Description IF YOU NEED ASSISTANCE OR SERVICE For the location of your nearest NuTone Independent Authorized Service Center Residents of the contiguous United States Dial Free 1 800 543 8687 Please be prepared to provide Product
18. rrupteur sont bien mis a la terre et que les fils sont conformes aux exigences des codes en vigueur pour un circuit de 120 V c a 15 A 1 Amenez un fil 120 V c a jusqu la bo te lectrique du thermostat et fixez le la bo te au moyen d un connecteur Utilisez du fil de calibre 14 avec mise la terre Consultez le diagramme de c blage 2 On recommande d installer un interrupteur dans l une des pi ces de la maison de fa on pouvoir fermer le ventilateur lorsqu il n est pas requis ACCESSOIRE OPTIONNEL vendu s par ment Le capteur thermique automatique AHS 200 permet de fermer le ventilateur si pour une raison ou une autre la temp rature du grenier s l ve au dessus de 93 C Garantie limit e d un an GARANTIE DU PROPRI TAIRE NuTone garantie l acheteur original de ses produits que ces derniers seront exempts de tout d faut de mat riaux et de fabrication pour une p riode d un 1 an compter de la date d achat AUCUNE AUTRE GARANTIE IMPLICITE OU EXPRESSE N EST DONNEE Y COMPRIS MAIS SANS S Y LIMITER GARANTIE DE MARCHANDIBILITE OU D ADAPTATION UN USAGE PARTICULIER Pendant cette p riode d un an NuTone proc dera au remplacement ou la r paration sans aucuns frais mais sa propre discr tion de tout produit ou pi ce jug d fectueux dans le cadre d une utilisation normale CETTE GARANTIE NE VISE PAS LES DISPOSITIFS D AMOR AGE NI LES TUBES DES LUMINAIRES FLUORESCENTS Cette garantie ne
19. uthorities C When cuiting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E If this unit is to be installed over a tub or shower it must be marked as appropriate for the application F NEVER place a switch where it can be reached from a tub or shower READ amp SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS Power Attic Ventilator MODEL RF 69NR RF 68HRPSC IMPORTANT For every 300 CFM of fan performance a minimum of one square foot of inlet space in attic or crawl space is necessary for proper operation Inlet areas should be located as far from fan location as possible such as in the eave or side walls MOUNTING THE FAN IMPORTANT If the fan will be mounted on a flat roof make a curb on which to mount the fan the fan must be above the level of the roof s water line 1 Determine location of fan center of attic near roof peak At desired location drill a hole through the roof centered between the rafters 2 Using the drilled hole as a center make a 14 diameter circle on the roof To make a circle a compass can be made of a scrap piece of wood with two nails placed 7 apart 3 Make cutout in roof along the circle that has been made If the roof is shingled cut shingles along the circle using the tin snips knife etc 4 Place fan over opening in roof Nail mounting flange to roof Caulk arou

Download Pdf Manuals

image

Related Search

Related Contents

mobile and secure tecra r10  WX01J 取扱説明書    2i Calibration Procedure for Service Providers Contents  DeLOCK Express Card to 4x USB 2.0  Instruction manual en Bedienungsanleitung de testo 523  I-AR-ADM-001  Pilates validé - Conservatoire Maurice Ravel Côte Basque  USER GROUP NEWS  ASTHMA CARE USER GUIDE - BLUEBAYCT  