Home
TRENDnet TPL306E2K Network Hardware User Manual
Contents
1. Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Product Overview l l u fall mmm ILLLLLLLI ii A TPL 306E TPL 306E2K Package Contents The TPL 306E package includes e 1x TPL 306E 200Mbps Compact Powerline AV adapter e Muti Language Quick Installation Guide e CD ROM Utility amp User s Guide e Network cable 1 5m 5ft The TPL 306E2K package includes e 2x TPL 306E 200Mbps Compact Powerline AV adapters e Muti Language Quick Installation Guide e CD ROM Utility amp User s Guide e 2xnetwork cables 1 5m 5ft If any package contents are missing or damaged please contact the retail store online retailer or reseller distributor that the item was purchased Copyright 2012 TRENDnet All Rights Reserved Features The 200Mbps Compact Powerline AV Adapter model TPL 306E uses any electrical outlet to create a secure high speed building wide network Connect one adapter to your existing network and plug another adapter in to any outlet on your electrical system for instant high speed network access throughout your home The compact form factor offers more space around electrical outlets for other devices Adapters connect automatically with no installation required For added security TRENDnet recommends using the one touch connect button to change the default network key Use up to 6 adapters to network devices in different rooms without
2. L Device 4 TL 125 00 ra Device IDDIE 152 00 Device Name Device Password Connection Speed or DPW Quality Link Rate Remote Devices Rate Mbps MAC Adds Scanning 10 30 47 15 34 35 10 30 47 TF 13 55 MAC Address Connect If your Powerline adapter Local Device is not detected automatically and does not appear in the list click Connect to detect and rescan and connecte to the Powerline adapter Local Device again Allows you to upgrade the Powerline adapter Upgrade Firmware Local Device firmware p ARE ee TRENDNET See page REES Rename Enter Password Add Scan remote locations that are Ser connected to the selected Scan Close Powerline adapter Local h Rescans the Powerline Device across the electrical ES VE i adapters that are system Rename Enter Password Add connected to your Note If all of your Powerline Renames the Allows you to Allows you to Powerline network adapters are already listed Powerline enter the DPW add a Powerline Remote Device connected to your Powerline adapter for the listed adapter to your network they will eren Powerline automatically detected and adapter appear in the list If not you will need to add them manually Remote Device Copyright 2012 TRENDnet All Rights Reserved Powerline network that is not listed Remote Device Close Closes and exits the Powerline Utility application 14 TRENDnet User s Guide TP
3. Note It is recommended to keep this option checked Enabled Copyright 2012 TRENDnet All Rights Reserved Close Closes and exits the Powerline Utility application 17 TRENDnet User s Guide TPL 306E TPL 306E2K Add adapters in the utility and create a customized encryption key If you have not written down the Device Password DPW and MAC address for each of your Powerline adapters please do so as it is required to applying the customized encryption key for all of your Powerline adapters using the utility Note Write down the Device Password DPW 16 digit characters A Z only and MAC Address 12 digit characters a f A F 0 9 of each Powerline adapter first before proceeding Example Location of Powerline Adapter Device Password DPW MAC Address To Router ZAYB VIMV YFAQ ZFPA 00 90 47 15 84 89 John s Room Jane s Room WECC ZZYC WJVY GZRS 00 90 47 15 84 88 UXMA UOUP IQXJ UTVN 00 90 47 1F 1A 85 Note It is recommended to ensure that your Powerline adapters are already installed and connected and the Ethernet port on each adapter is connected to a device powered on First add all of the Powerline adapters to the utility and enter the Device Password DPW for each Powerline adapter to ensure you can change the encryption key for multiple adapters This is required when using the Powerline utility to change the encryption key for multiple Powerline adapters To add automatically detected Pow
4. Resets the unit to factory defaults Solid a Connected Connection Quality is est Syncing or Powerline Data Blinking Transmitting Receiving Connection Quality is Best PL Solid Connected Connection Quality is Powerline etter ae Powerline Data Transmitting Receiving Blinking en Connection Quality is Better Powerline Connected Connection Quality is Solid Good ejjed Powerline Data Transmitting Receiving Blinking De Connection Qualitv is Good Initiate Sync Connection and generate random network name key on first adapter PWR LED will start blinking Match network name key on secondary or additional adapter and connect to first adapter PWR LED will Push Hold for 2sec lt blinking Note The secondary or additional Powerline adapter s Sync button must also be pushed within 2 minutes 120 sec of pushing the Sync button of the first adapter in order to establish connectivity Off Powerline is not synced or connected 10 20 Mbps or 100 200Mbps Half Full Solid Duplex Connected Ethernet a 10 20Mbps or 100 200Mbps Half Full Blinking WW Connection Duplex Data Transmitting Receiving Off Port Disconnected No Ethernet Link Push Hold for 10 Erases the network name kev sec All LEDs will turn off and turn back on Reset device to factory defaults All LEDs will turn off and turn back on Push Hold for 1 sec Note Will reset to the factory default private network name HomePlugAV Note
5. 64 bit Vista 32 64 bit XP 32 64 bit Temperature Operating 0 40 C 32 104 F Overlapping Powerline Up to 4 per electrical system Humidity Max 90 non condensing Networks Supported ma Certifications CE FCC HomePlug AV 128 Bit AES Advanced Encryption Standard Maximum of 6 adapters nodes for streaming video across your network LED Power PWR 200Mbps is the maximum theoretical Powerline data rate Actual throughput will vary depending on environment Powerline PL Connection l l l Networked Powerline devices need to be plugged into power outlets that are on the same Best Green electrical system Better Amber GFCI outlets and AFCI circuit breakers may degrade Powerline network signals Good Red No connection Off Copyright 2012 TRENDnet All Rights Reserved 22 TRENDnet User s Guide TPL 306E TPL 306E2K Troubleshooting B Please reference the items below if vou continue to experience difficultv with installing and using vour Powerline adapters e Try power cycling the unit by unplugging it from the wall power outlet for 15 seconds and plugging it back in e Ifthe Powerline PL LED is red indicating good quality only try plugging the Powerline adapter into another available wall power outlet to check if you can obtain better connection quality e If you are having issues connecting the Powerline adapters after changing the encryption key using the Sync button or Powerlin
6. OF THE PURCHASE PRICE PAID AT TRENDNET S OPTION THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE Governing Law This Limited Warranty shall be governed by the laws of the state of California Some TRENDnet products include software code written by third party developers These codes are subject to the GNU General Public License GPL or GNU Lesser General Public License LGPL Go to http www trendnet com gpl or http www trendnet com Download section and look for the desired TRENDnet product to access to the GPL Code or LGPL Code These codes are distributed WITHOUT WARRANTY and are subject to the copyrights of the developers TRENDnet does not provide technical support for these codes Please go www gnu org licenses gpl txt or http www gnu org licenses lgpl txt for specific terms of each license 2 TRENDNET Product Warranty Registration Please take a moment to register your product online Go to TRENDnet s website at http www trendnet com register TRENDnet 20675 Manhattan Place Torrance CA 90501 USA Copyright 2012 All Rights Reserved TRENDnet
7. See Product Hardware Features on page 2 Ne e Please ensure that your Powerline adapters are already installed and connected and the Ethernet port on each adapter is connected to a device powered on Upon completing the software installation a desktop shortcut is automatically created Double click the icon to start the utility or open the utility if it is already running Closing Installation Complete the utility will exit the application TRENDnet Powerline Utility has been successfully installed Click Close to exit TRENDnet Powerline Utility You can also launch the utility from the Start Menu programs Start gt Programs or All Programs gt TRENDnet gt TRENDnet Powerline Utility TRENDnet A TRENDnet Powerline Utility Close 17 Reboot your computer to complete the installation Wi TRENDnet Powerline Utility Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Powerline Utilitv Overview Main Window Main Privacy Diagnostics About Local Device Local Levicelzj on pour computer HomePlug AV 6405 D 00 90 47 15 84 89 Connect The Powerline adapter connected to your router Upgrade Firmware 2 Powerline Devices detected Network Tupe Public Note If your computer is connected directly to your Powerline adapter the Local Device listed will be the Powerline adapter your computer is directly connected j j j j
8. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING Copyright 2012 TRENDnet All Rights Reserved WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TRENDNET NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF TRENDNET S PRODUCTS TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMIPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS LOSS OF INFORMATION OR DATE OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF THE POSSIBILITY OF SUCH DAMAGES AND LIMITS ITS LIABILITY TO REPAIR REPLACEMENT OR REFUND
9. X FINAL nvm aoo DS 8 Click OK Please select appropriate Firmware and PIE files Cr WUsers user 100420 Desktop aM le Powerline Bridge TPL 40 1E v 1 0R Browse Wait until the firmware upload completed and the device reboot Important Do not turn off the device or press the reset button while this procedure is in progress 21 TRENDnet User s Guide TPL 306E TPL 306E2K Technical Specifications a U e Solid Hardware e Blinking IEEE 802 3 IEEE 802 3x IEEE 802 3u HomePlug AV IEEE e Off 1901 Svnc Reset interface 1x 10 100Mbps Auto MDIK RAS Por Buttons Ismemet O Power prong Dimension Lx W X H A 55 x 87 x 51 mm 2 2 x 3 4 x 2 in per unit e A North America Tvpe B NEMA 5 15 EU 55x 87x 65mm 2 2 xX 3 4 x 2 6 in per unit e EU Euro Type C CEE 7 16 UK 55 x 87 x 58 mm 2 2 x 3 4 x 2 3 in per unit e UK United Kingdom Type G BS 1363 A Total Weight 148 g 5 2 oz Per Unit Weight 74 g 2 6 OZ Frequency Band 2 28 MHz EU Total Weight 158 8 g 5 6 oz Per Unit Weight 79 4 g OFDM Symbol modulation on link synchronization 2 8 oz 1024 256 64 8 QAM QPSK BPSK ROBO carrier UK Total Weight 170g 6 oz Per Unit Weight 85 3 oz TDMA and CSMA CA Power Source 100 240V AC 50 60Hz Speed Powerline Up to 200Mbps Consumption Active mode 3 1 Watts max Ethernet Up to 200Mbps Full Duplex mode Standby mode 0 5 Watts max Utility OS Compatibility Windows 7 32
10. appears as a number and letter code in groups of four separated by dashes lie skEr GH26 BA1K L254 Ibis found on the device or packaging Cancel 6 If successful you will receive a message indicating that the password is correct Click OK Repeat steps 2 6 for each additional Powerline adapter listed in Remote Device until you have added all of your remaining Powerline adapters before continuing to the next step To create a customized encryption key Copyright 2012 TRENDnet All Rights Reserved To create a customized encryption key 1 In the Powerline Utility Privacy window under Private Network Name enter the new encryption key for your Powerline network Main Privacy Diagnostics About Use this screen ta create a Private Network that provides you with estra security OF Use Default Public Network Lia not share the network name with others you do not want ta be part of this network Private Network Name 2 After you have entered your new Powerline encryption key click Set All Devices After zetting the name above choose how it wll be applied below Place On This Network Only the device attached ta this computer the Local Device Set Local Device Onl Isolates this computer from others ef Local Device Ur OR ALL devices whose Password has been entered They communicate together but are isolated from devices with Cet All Devices a different network name 3 Click OK If s
11. called network cable from the Ethernet port also called network port of your Powerline adapter to an available Ethernet port also called LAN port on your router 3 Once the Powerline adapter is installed and connected to your router verify that the Power PWR LED is on or blinking and the Ethernet Connection ETH LED is on or blinking TRENDnet User s Guide TPL 306E TPL 306E2K Add adapters to vour network Once vou have installed and connected the first Powerline adapter to vour router vou can easilv extend vour network to other rooms bv adding additional Powerline adapters To extend vour network using an additional Powerline adapter 1 First make sure the first Powerline adapter is installed and connected to vour router Note This will allow devices connected to vour Powerline network to access the Internet and other devices connected to vour network See Connect a Powerline adapter to vour router on page 5 2 Plug the additional Powerline adapter into an available wall power outlet in another room near a computer or network device e g game consoles network enabled TVs network attached storage network media server plavers etc that vou would like to connect to vour network 3 Connect the included Ethernet cable also called network cable from the Ethernet port also called network port on vour Powerline adapter to the to the Ethernet port of vour computer or network device 4 After the additiona
12. 1 Delete Deletes or removes the selected entry listed in the Remote Device History Log Remote Device Save Report Saves the information contained in the System Information window to a text file on your computer Print Report Prints the information contained in the System Information window Close Closes and exits the Powerline Utility application 16 TRENDnet User s Guide TPL 306E TPL 306E2K Svstem Information Displavs copvright information Vou can verticallv scroll the window to view all of the copvright information Powerline Utilitv Overview About Window Main Privacy Diagnostics About TRENDNET TRENDnet Powerline Utility Version Released Copyright 2005 2010 Atheros Communications Inc All Rights Reserved http ww Wendel com License Copyrights Copyright cj 1999 2005 NetGroup Politecnico di Torna Italy Copyright cj 2005 2009 LALE Technologies Davis California All rights reserved Redistribution and use in source and binary forme with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer Preferences AutoScan Enables or disables the autoscan feature for automatically discovering Powerline adapter or devices Remote Device connected to your Powerline network
13. 3 At the CD ROM main menu click Install Utility Install Utility User s Guide Product Registration 4 Click OK Note The Powerline Configuration Utility requires the use of the WinPcap application If this prompt does not appear you may already have the WinPcap application installed If so please skip over to Step 11 WinPcap Software version 4 1 2 ts either not installed or some previous version is already installed on this workstation The WinP cap version 4 1 2 installer is being launched Please follow the instructions for installing the WinP cap software Copyright 2012 TRENDnet All Rights Reserved 5 At the WinPcap installer window click Next D WinPcap 412 set WinPcap 4 1 2 Installer W IV edp Welcome to the WinPcap 4 1 2 Installation Wizard This product is brought to you by CACE TECHNOLOGIES Packet Capturing and Network Analysis Solutions 6 In the Setup Wizard window click Next IT Winpcap 4 12 Setul Welcome to the WinPcap 4 1 2 Setup Wizard This Wizard will guide you through the entire WinPcap installation For more information or support please visit the WinPcap home page http www winpcap org TRENDnet User s Guide TPL 306E TPL 306E2K 7 In the License Agreement window click I Agree H i License Agreement A in edp Please review the license terms before installing WinPcap 4 1 2 Press Page Down to see the rest of the agreem
14. L 306E TPL 306E2K Powerline Utility Overview Privacy Window Main Privacy Diagnostics About Use this screen ta create a Private Network that provides you with estra security Use Default Public Network Do not share the network name with others you do not want to be part of this network Use Default Public Network Replaces the current encryption key value with the default HomePlugAV Note You will still need to apply the settings to your Powerline adapters by clicking Set Local Device Only or Set All Devices Encryption Key Private Network Name Encryption key for your OF Powerline network Note The default encryption key is HomePlugAV If you have used the Sync button to change and generate a Nokia ABO A Dee a I aie eea SeLoc Device Or will be displaved OR ALL devices whose Password has been entered They communicate together but are isolated from devices with Get All Devices a different network name After setting the name above choose hom it will be applied below Place On This Network Set Local Device Only Changes the encryption key for the Powerline adapter listed as the Local Device on the adapter on the Main window Note If you change the encryption key for the Powerline adapter Local Device this will disconnect the Local Device Powerline adapter from the Powerline network Set All Devices Changes the encryption key for all or multiple Powerline adapter
15. The following factors may affect the Powerline network s connection quality e Noise Generated by appliances that are connected to your electrical system through power outlets that have high power consumption requirements e g Microwaves ovens blow dryer iron dishwasher etc The quality of your household electrical wiring may also cause additional noise on your electrical system e Distance Long lengths of electrical wiring through your electrical system between connected Powerline adapters e Power Prong Plugs into an available power outlet e Diagnostic LEDs Indicates the device status and connectivity Note Powerline PL LED color indicates the strength and quality of the Powerline connection through the electrical system Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Power Saving The device will automatically reduce power usage when the connected Application Diagram devices via Ethernet are powered off unplugged or inactive for more than 3 minutes Powerline Networking solution Erp EuP Operation Standby Mode e Disconnect the Ethernet cables from the device Ethernet ports and after 3 minutes the device will enter standby mode The Power PWR LED will flash every 15 seconds to indicate that the device is currently in standby mode e Toreturn to active mode reconnect the Ethernet cables to the device Ethernet ports and the device will re enter act
16. al Powerline adapter 3 Push and hold the Svnc button on one of the existing Powerline adapters connected to vour Powerline network for 2 seconds and release it The Power PWR LED will start blinking 4 Within 2 minutes push and hold the Svnc button on the additional Powerline adapter for 2 seconds and release it The Power PWR LED will start blinking This will reconfigure vour additional Powerline adapter to connect and use the encrvption kev of your existing Powerline network All LEDs will turn off and turn back on and the Powerline PL LED will turn on the adapters are connected To reconfigure the encrvption kev and connect additional Powerline adapters to vour existing Powerline network repeat the steps above for each adapter Using the Powerline Utilitv The Powerline Utilitv allows vou to do the following Create a customized encryption key for your Powerline network and apply it to multiple Powerline adapters at the same time Allows you to view the Powerline adapters connected to your network using the MAC address and the approximate connection quality and speed of each Powerline adapter View and upgrade your Powerline adapter firmware version Note Link speed displayed in the utility of your Powerline adapters to another through your electrical system is estimated Actual link speed may vary Before installing and using the utility please ensure the following Write down the Device Password DPW 16 digit ch
17. aracters A Z only and MAC Address 12 digit characters a f A F 0 9 of each Powerline adapter as this will be required to change the encryption key for multiple Powerline adapters See Product Hardware Features on page 2 Make sure your computer in which you are installing the utility is connected to your network and your Powerline adapters are also connected to your network If you have changed your encryption key using the Sync button and you are creating a customized encryption key it is required to reset all Powerline devices to defaults using the physical Reset button on your Powerline adapter first before using the utility See Product Hardware Features on page 2 Please ensure that your Powerline adapters are already installed and connected and the Ethernet port on each adapter is connected to a device powered on Powerline Utility System Requirements Supported Operating Systems CPU 1GHz or above 1GB RAM or above Windows 7 32 64 bit Windows Vista 32 64 bit Windows XP 32 64 bit 800MHz or above 512MB RAM or above 300MHz or above 256MB RAM or above Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Software Installation 1 Insert the included CD ROM into your Computers CD ROM drive 2 At the CD Autorun Prompt window click Run Autorun exe Note If the Autorun prompt does not appear automatically open the CD contents and double click Autorun exe
18. direttiva 2004 108 CE Ar o TRENDnet deklar ka TPL 306E atbilst Direkt vas 2004 108 EK butiskajam prasibam un citiem ar to saistitajiem Copyright 2012 TRENDnet All Rights Reserved Lietuviy Lithuanian nl Nederlands Dutch Malti Maltese hu Magyar Hungarian Le Polski Polish Portugu s Portuguese Lt Slovensko Slovenian Slovensky Slovak ti Suomi Finnish Svenska Swedish noteikumiem Siuo TRENDnet deklaruoja kad is TPL 306E atitinka esminius reikalavimus ir kitas 2004 108 EB Direktyvos nuostatas Hierbij verklaart TRENDnet dat het toestel TPL 306E in overeenstemming is met de essenti le eisen en de andere relevante bepalingen van richtliin 2004 108 EG Hawnhekk TRENDnet jiddikjara li dan TPL 306E jikkonforma mal ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid Dirrettiva 2004 108 EC Alulirott TRENDnet nvilatkozom hogv a TPL 306E megfelel a vonatkoz alapvet k vetelm nyeknek s az 2004 108 EC iranyelv egyeb eldirasainak Niniejszym TRENDnet oswiadcza ze TPL 306E jest zgodny z zasadniczymi wymogami oraz pozostatymi stosownymi postanowieniami Dyrektywy 2004 108 EC TRENDnet declara que este TPL 306E esta conforme com os requisitos essenciais e outras disposi es da Directiva 2004 108 CE TRENDnet izjavlja da je ta TPL 306E v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo ili direktive 2004 108 ES TREND
19. e networks Note Assuming all powerline adapters are TRENDnet Powerline adapters and for reference in the diagram and this procedure the adapters will be labeled Adapter A B C D and E Adapters A B and C are currently connect together to form one powerline network and Adapters D and E form another powerline network Adapter B will be disconnected from Adapters A and C and connected to Adapters D and E Powerline Group 1 Powerline Group 2 Encryption Key key1 Encryption Key key2 Adapter B Adapter D mm wm Electrical Wiring ms Electrical Wiring Powerline Group 1 Powerline Group 2 1 Push and hold the Sync button on Adapter B for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current encrvption kev assigned to Adapter B and disconnect from Adapter A and Adapter C 2 Push and hold the Svnc button on Adapter D for 2 seconds and release it The Power PWR LED will start blinking 3 Within 2 minutes push and hold the Svnc button on Adapter B for 2 seconds and release it The Power PWR LED will start blinking This will establish connectivitv between Adapter B Adapter D and Adapter E bv reconfiguring the encrvption kev of Adapter B to match the encryption key of Adapter D and Adapter E All LEDs will turn off and turn back on and the Powerline PL LED will turn on the when adapters are connected 24 TRENDnet User s Guide TPL 306E TPL 306E2K Federal C
20. e utility reset the Powerline adapters to defaults using the physical Reset button e Use a pin or paperclip and push and hold the Reset button for 1 second on each Powerline adapter All LEDs will turn off and turn back on This will reset the Powerline adapters to their default settings default encryption key assignment HomePlugAV e The Powerline adapters can provide better connectivity and performance when plugged directly into a wall power outlet instead of a power strip or surge protector e Connecting the Powerline adapters to a power strip or surge protector may degrade Powerline performance e Using the Powerline adapters on GFI protected outlets and electrical systems with AFCI circuit breakers as these items may degrade Powerline performance e The Powerline adapters should not be used in areas with excessive heat e Certain florescent or incandescent lights are noise sources on the electrical system and can degrade Powerline performance Copyright 2012 TRENDnet All Rights Reserved If your building has more than one circuit breaker box the Powerline adapter may not be able to establish connectivity between different circuit breaker boxes In this case connect a Powerline adapter into a wall power outlet located on each of the circuit breaker boxes and then connect an Ethernet cable between the Powerline adapters to bridge the two circuits together This will allow the Powerline adapters from different circuit breaker box
21. ease ensure that your other Powerline adapter is HomePlug AV or IEEE 1901 compliant e g TRENDnet models TPL 303E TPL 304E TPL 305E TPL 307E TPL 310AP TPL 401E TPL 402E TPL 405E or another TPL 306E The TPL 306E2K package already includes two Powerline adapters 2 Plan the location of where you will install your Powerline adapters e Avoid plugging the adapters into power strips extension cords or surge protectors as this may prevent the adapter from functioning correctly such as degrading performance e Avoid plugging the adapters into wall power outlets that are controlled by a switch to prevent the Powerline adapter from being turned off accidentally e Avoid plugging the adapters into wall power outlets that are located near appliances that consume a lot of power e g refrigerators washers dryers as this may degrade performance e Make sure there is an available wall power outlet in the room where the router is installed and also near the router e Make sure there is an available wall power outlet in the room where you want to extend your network connectivity Copyright 2012 TRENDnet All Rights Reserved Connect a Powerline adapter to your router 1 Plug the Powerline adapter into an available wall power outlet near your router Note This will allow devices connected to your Powerline network to access the Internet and other devices connected to your network 2 Connect the included Ethernet cable also
22. ent Copyright e 1999 2005 NetGroup Politecnico di Torino Italy Copyright c 2005 2010 CACE Technologies Davis California All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disdaimer in the documentation and or other materials If you accept the terms of the agreement dick I Agree to continue You must accept the agreement to install WinPcap 4 1 2 8 In the Install Options window leave the option Automatically start the WinPcap driver at boot time checked and click Install Installation options Please review the following options before installing WinPcap 4 1 2 Copyright 2012 TRENDnet All Rights Reserved 9 Wait for the WinPcap installation to complete inPeap pre while WinPcap 4 1 2 is being installed Extract driversinpf svs 100 RP aa amp 3 amp Completing the WinPcap 4 12 Setup Wizard Winf cap 4 1 2 has been installed on your computer Click Finish to dose this wizard Cancel 11 TRENDnet User s Guide TPL 306E TPL 306E2K Welcome to the TRENDnet Powerline Utility Setup Wizard The installer will g
23. erline adapters to the Powerline Utility 1 Launch the Powerline Utility d Powerline Utilitv TRENDnet Copyright 2012 TRENDnet All Rights Reserved 2 In the Powerline Utility Main window wait for the utility to automatically scan for Powerline adapters already connected to your Powerline network If your Powerline adapters have already been installed and connected using the same encryption key they should appear in the Remote Device list Main Privacy Diagnostics About Local Lievicels on your computer MAC Address Connected to HomePlug AY 6405 Device Device Type IU HomePlug 44 6405 D 00 30 47 15 94 89 Upgrade Firmware Network Type Public Rate Mbps MAC Address 2 Powerline Devices detected 4utoscan On wW Device 4 NNI 128 00 O00 30 47 7 5 84 58 L Dawre ITT 152 00 00 90 47 1F 1A 85 TRENDNET Rename Enter Password Add Scan 3 Select one of the Powerline adapters listed under Remote Device 2 Powerline Devices detected Autoscan On Network Type Public UI 132 00 DU OU 47 15 04 89 Lei Device 7 IHN 152 00 00 90 47 1F 14 85 4 Click Enter Password Enter Password TRENDnet User s Guide TPL 306E TPL 306E2K 5 Enter the Device Password DPW and click OK Note Match the Device Password DPW to the corresponding MAC address Device Device A 00 30 47 715 64 58 Password WE COZ CWI DD The Password typically
24. es connect to each other In addition to this User s Guide you can find help below e http www trendnet com support documentation downloads FAQs how to contact technical support e Autorun CD Quick Installation Guide 23 TRENDnet User s Guide TPL 306E TPL 306E2K Appendix Overlapping Powerline networks It is possible to create multiple Powerline networks on the same electrical system separated and grouped by different network encryption keys The Powerline networks will work and communicate independently of each other which can provide security between different groups of Powerline adapters For example if you have five powerline adapters Adapter A Adapter B Adapter C Adapter D Adapter E you can group Adapters A B and C together on one powerline network and group Adapters D and E ona different Powerline network Each group will use a different encryption key Note It is recommended that only a maximum of up to 4 Powerline networks can be created per electrical system Any additional Powerline networks above the recommended may result in significant degradation in Powerline performance Powerline Group 1 Powerline Group 2 Encryption Key key1 Encryption Key key2 Adapter B Adapter D ee Electrical Wiring ee ma Electrical Wiring Powerline Group 1 Powerline Group 2 Copyright 2012 TRENDnet All Rights Reserved Move Powerline adapters between different overlapping Powerlin
25. i TRENDNET 200Mbps Compact Powerline AV Adapter 200Mbps Compact Powerline AV Adapter Kit TPL 306E TPL SO6E2K TRENDnet User s Guide Table of Contents Contents PROGUCE e ENT 1 Package COM EMIS ee ee rn 1 Fr UI ER ELDER IE A E A A 1 Product Hardware Features E 2 Application Diagram ENEE 4 Installing your Powerline Adapters ssssssesnenezenenennenenezzaneneneneznetu 5 Before you NE Eee ne ee 5 Connect a Powerline adapter to your router LL ess ennnnnnzzonnnnnnzzonrenznnzznrnnznzzznennznzzza 5 Add adapters to your network EEN 6 Securing your Powerline Network Lssssesenenezenenneneneneznenenenezzonenza 7 Using en eer de 7 Change your default encryption key using the Sync button 7 Add adapters using the SYNC button 8 Using the Powerline UtilitVv sssssesnnnnenezennzenerenenzanenenenzanenenenzanenz 9 Powerline Utility System Requirements 000 ess ssnnnnnnnzznnnenknzznnnenznnzznnnnnnzzzznrnnnnzznnnna 9 Software Installation a EE SE E EA 10 EINE tne U ne ee ee een 13 Powerline Utility Overview eeeesseesesesnnssssnesnnnnnnnnennnnnnnnonnnnnnnnonnnnnnnnnnnnnsnnennnensnnennnenn 14 Add adapters in the utility and create a customized encryption key 6 18 Upgrade Firmware ccccsscccccssscccssseccseeccccenscecsussecssauceeseuseessueeeeseaeeessauseessaeeessaases 20 Technical SpecificationS essssesessesessecessecessecesoscecsscessssesesoesseseo 22 GEES 23 Meel L G A 24
26. interference received including interference that may cause undesired operation C IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Copyright 2012 TRENDnet All Rights Reserved The availability of some specific channels and or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination The firmware setting is not accessible by the end user RoHS This product is ROHS compliant Europe EU Declaration of Conformity This device complies with the essential requirements of the Directive 2004 108 EC The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the Directive 2004 108 EC e EN 55022 2006 A1 2007 e EN 61000 3 3 2008 e EN 50412 2 1 2005 e EN 60950 1 2006 A11 2009 29 TRENDnet User s Guide TPL 306E TPL 306E2K Cesky Czech Dansk Danish Deutsch German Eesti Estonian en English es Espafiol Spanish EAAnVikKh Greek Francais French Lt Italiano Italian Latviski Latvian TREND
27. ive mode wem em wem m wem ef eg 10 100Mbps Powerline A router is alreadv installed in the room where the xDSL Cable modem tvpicallv supplied bv vour ISP Internet Service Provider is located in order to phvsicallv connect an Ethernet cable also called network cable from the router WAN port to the modem network port which connects to the Internet A second Powerline adapter is plugged into a wall power outlet in another room in order to extend the network connectivitv to the network devices in that room The Ethernet port of the second Powerline adapter is then connected to a network enabled TV or other network enabled media device in order to extend connectivitv to these devices allowing access to vour network and to the Internet through the electrical svstem Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Installing vour Powerline Adapters Before vou Install 1 Before vou proceed with the installation verifv the following e You already have an existing Ethernet network along with a router already installed e You already have Internet access through your existing network e An Ethernet port also called LAN port is available on your router e Verify that you have at least two Powerline adapters You will need at least two Powerline adapters to create a Powerline network Note The TPL 306E package only includes a single Powerline adapter Pl
28. l Powerline adapter is connected and installed to vour computer or network device wait for the Powerline PL LED to turn on After the Powerline PL LED turns on verify that the Power PWR LED is on the Powerline PL LED is on or blinking and the Ethernet Connection ETH LED is on or blinking Note To verify that your Powerline adapters are connected successfully to your network you can check if the computers or network devices are able to access the Internet through your Powerline adapters or using a computer check if you are able to access the network devices connected to your network To install additional Powerline adapters in other rooms repeat the steps above for each adapter Copyright 2012 TRENDnet All Rights Reserved TRENDnet User s Guide TPL 306E TPL 306E2K Securing vour Powerline Network Powerline networks consist of two or more Powerline devices connected together using the same encrvption kev At default settings all TRENDnet Powerline adapters are assigned the same encrvption kev and there is no additional setup required for the first installation Vou would simplv need to plug the TRENDnet Powerline adapters into aVailable wall power outlets and the adapters will connect to each other using the default encryption key HomePlugAV and create your Powerline network automatically In order for your Powerline devices to connect to the same Powerline network the same encryption key must be assigned to a
29. ll Powerline devices in that network Powerline devices that are not assigned the same encryption key will not be able to connect to the Powerline network For additional security it is recommended that you can change the default encryption key to prevent anyone nearby with a Powerline network from gaining access to your network Note After the default encryption key has been changed and the Powerline adapters have been connected using a new encryption key the Powerline adapters will retain their security settings when they are unplugged and moved to a new location No additional reconfiguration of the Powerline adapters is needed after the default encryption has been changed There are two methods you can change the default encryption key e Use the physical Sync button on your Powerline adapter to generate a random encryption key See Using the Sync Button on page 7 OR e Create a customized encryption key for your Powerline network using the included Powerline Utility See Using the Powerline Utility on page 9 Copyright 2012 TRENDnet All Rights Reserved Using the Sync button Change your default encryption key using the Sync button The physical Sync button on the Powerline adapter provides an easy method of changing the default encryption key The Sync button generates a random encryption key for your Powerline network To create a customized encryption key see Using the Powerline Utility on page 9 N
30. ll ta a different folder enter it below or click Browse Folder C Program Files T RENDnet TRENDnet Powerline Utility Install TRENDnet Powerline Utility for yourself or for anyone who uses this computer 7 Everone o Just me 14 In the Confirm Installation window click Next Contirm Installation The installer i ready to install TRENDnet Powerline Utility on your computer Click Next to start the installation 12 TRENDnet User s Guide TPL 306E TPL 306E2K 15 Wait for the Powerline Utility installation to complete Using the Utility J TRENDnet Powerline Utility detengde ES E MEINE SARIG Sa Before using the utility please ensure the following e Write down the Device Password DPW 16 digit characters A Z only and MAC TRENDnet Powerline Utility is being installed Address 12 digit characters a f A F 0 9 of each Powerline adapter as this will be required to change the encryption key for multiple Powerline adapters See Product Hardware Features on page 2 Please wait e Make sure your computer in which you are installing the utility is connected to your network and your Powerline adapters are also connected to your network e Ifyou have changed your encryption key using the Sync button and you are creating a customized encryption key it is required to reset all Powerline devices to defaults using the physical Reset button on your Powerline adapter first before using the utility
31. net t mto vyhlasuje e TPL 306E sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 2004 108 ES TRENDnet vakuuttaa t ten ett TPL 306E tyyppinen laite on direktiivin 2004 108 EY oleellisten vaatimusten ja sit koskevien direktiivin muiden ehtojen mukainen H rmed intygar TRENDnet att denna TPL 306E star verensst mmelse med de v sentliga egenskapskrav och vriga relevanta best mmelser som framg r av direktiv 2004 108 EG 26 TRENDnet User s Guide Limited Warranty Limited Warranty TRENDnet warrants its products against defects in material and workmanship under normal use and service for the following lengths of time from the date of purchase TPL 306E TPL 306E2K 3 Years Warranty AC DC Power Adapter Cooling Fan and Power Supply carry 1 year warranty If a product does not operate as warranted during the applicable warranty period TRENDnet shall reserve the right at its expense to repair or replace the defective product or part and deliver an equivalent product or part to the customer The repair replacement unit s warranty continues from the original date of purchase All products that are replaced become the property of TRENDnet Replacement products may be new or reconditioned TRENDnet does not issue refunds or credit Please contact the point of purchase for their return policies TRENDnet shall not be responsible for any software firmware information or memory data of c
32. net timto prohlasuje ze tento TPL 306E je ve shod se z kladn mi po adavky a dal mi p slu n mi ustanoven mi sm rnice 2004 108 ES Undertegnede TRENDnet erkl rer herved at f lgende udstyr TPL 306E overholder de v sentlige krav og vrige relevante krav i direktiv 2004 108 EF Hiermit erkl rt TRENDnet dass sich das Ger t TPL 306E in bereinstimmung mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen der Richtlinie 2004 108 EG befindet K esolevaga kinnitab TRENDnet seadme TPL 306E vastavust direktiivi 2004 108 EU p hin uetele ja nimetatud direktiivist tulenevatele teistele asjakohastele s tetele Hereby TRENDnet declares that this TPL 306E is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC Por medio de la presente TRENDnet declara que el TPL 306E cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 2004 108 CE ME THN TIAPOV A TRENDnet AHAQNEI OTI TPL 306E VMMOPQOONETAI MPO TI OV IQAEIZ ANAITHZEIZ KAI TI AOINE 2XETIKEZ AIATA EIZ TH2 OAHTIAZ 2004 108 EK Par la presente TRENDnet d clare que l appareil TPL 306E est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 2004 108 CE Con la presente TRENDnet dichiara che questo TPL 306E conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla
33. ommunication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur ina particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any
34. ote The default encryption key assigned to TRENDnet Powerline adapters is HomePlugAV Before changing the default encryption please ensure that your Powerline adapters are already installed and connected using the default encryption key See Installing your Powerline Adapters on page 5 1st Adapter 2nd Adapter Modem Router o OY Cl Ethernet zm Electrical Wiring Powerline Network TRENDnet User s Guide TPL 306E TPL 306E2K To change the default encrvption kev between two Powerline adapters 1 Verifv that all Powerline adapters are alreadv installed and connected using the default encryption key see Installing your Powerline Adapters on page 5 2 On one of your connected Powerline adapters push and hold the Sync button for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current encryption key assigned to the first Powerline adapter Note Once you complete this step the other Powerline adapter will not be able to communicate to this Powerline adapter 3 Push and hold the Sync button on the other Powerline adapter for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current encryption key assigned to the second Powerline adapter 4 Within 2 minutes push and hold the Sync button on the first Powerline adapter for 2 seconds and release it The Power PWR LED will start blinking This will generate a random encr
35. owerline model http www trendnet com downloads 2 Save the zipped firmware file zip and extract the file to your computer 3 Make sure you connect your computer with the utility installed is directly connected to the Powerline adapter using an Ethernet cable also called network cable when upgrading the device firmware 20 TRENDnet User s Guide TPL 306E TPL 306E2K 4 Launch the Powerline Utility by double clicking the icon TRENDnet Powerline Utility 5 The device should appear in the Main window of the utility under Local Device Click Upgrade Firmware TRENDnet Powerline Utility are Main Privacy Diagnostics About Local Device s on your computer Device Type MAC Address HomePlug Au 7400 D 00 30 47 1E CF 9D Connected to HomePlug AV r400 Device Connect Upgrade Firmware U Powerline Devices detected Network Type Private Scanning DeviceName Password Quality Fate Mbps MAC Address TRENDNET Rename Enter Password Copyright 2012 TRENDnet All Rights Reserved 6 Click Browse next to the PIB field and navigate to the unzipped folder with the firmware files Select the PIB file Ex TPL 401E PIB v50100 pib Please select appropriate Firmware and PIB files PIB NVM 7 Click Browse next to the NVM field and navigate to the unzipped folder with the firmware files Select the NVM file Ex TPL 401E NVM v5 0 1 0 0
36. s connected to your Powerline network Note Please make sure you have added and entered the DPW for all Powerline adapters in your Powerline network before applying this setting If you do not the encryption key will not change for any Powerline adapters without the DPW entered Copyright 2012 TRENDnet All Rights Reserved Close Closes and exits the Powerline Utility application 15 TRENDnet User s Guide TPL 306E TPL 306E2K Powerline Utilitv Overview Diagnostics Window Main Privacy Diagnostics About System Information Displays the device and other related information such as firmware version MAC address and encryption key also called network password You can vertically scroll the window to view all of the system information Remote Device History Log Displays Powerline adapters or other Powerline devices Remote Device that have been previously connected to or discovered on your Powerline Network System Information Un NIC 1 MAC HomePlug Device 1 MAC Network password HomeFlug i Vendor Firmware Computer network name XXNX Device g Copyright 2012 TRENDnet All Rights Reserved Remote Device History Log MAC Address Rate Mbps Network MEARE UU DU 47 1 5 94 98 II Delete not entered not entered Save Report Unknown HomePlug S Print Report Last Seen Jul 20 01 43PM Oct 17 12 4 74M b 1
37. the need for new cabling Power Save mode reduces power consumption by up to 80 LED displays convey device status for easy power management and troubleshooting Quality of Service technology prioritizes video audio and online gaming Advanced AES encryption secures your network This adapter is ideal for use in buildings that interfere with wireless networking signals e 200Mbps building wide networking over an existing connected electrical system e Compliant with the HomePlug AV and IEEE 1901 standard e 1x 10 100Mbps Auto MDIX Ethernet Port e Compact form factor saves space e One touch Sync button to change the default encryption key e Connect one 200Mbps Powerline AV Adapter to the Internet and then plug in up to 5 additional Powerline AV adapters for instant building connectivity e Share data intensive files play games download music and more at faster data transfer rates e Advanced 128 bit AES encryption to ensure total network security e Power Save mode reduces electrical consumption by 80 e Neighbor network support for up to 4 overlapping networks e Three LED indicators Power on off Powerline Connection green best amber better red good off no connection Ethernet Connection solid connection blinking transfer activity off no connection e Network signal transmits up to 300 meters 984 ft e Auto QoS support through traffic classification and multiple priority queuing e Compatible with all opera
38. ting systems TRENDnet User s Guide TPL 306E TPL 306E2K e Optional management utility compatible with Windows 7 32 64 bit Vista 32 64 bit and XP 32 64 bit operating systems Maximum of 6 adapters nodes for streaming video across your network 200Mbps is the maximum theoretical Powerline data rate Actual throughput will vary depending on environment Networked Powerline devices need to be plugged into power outlets that are on the same electrical system Product Hardware Features Device Label Product Model Device Serial Number Device MAC Address Device Password DPW Hardware Version Firmware Version TRENDNET MODEL NO d D I MAC DPW VARS ECHE SAGA OWED HAW V1 0R F W This device complies with Part 15 of FCC Rules Made in China Copyright 2012 TRENDnet All Rights Reserved Ethernet Connection ETH LED a I got D Power PWR LED Reset Button gt Powerline PL LED L Sync Sync Button Ethernet Port e Fc cm __ Power Prong MITEL Et TRENDnet User s Guide TPL 306E TPL 306E2K e Ethernet Port Connect an Ethernet cable also called network cable from an LED Color Sequence Definition your Powerline adapter Ethernet port and to your computer or network device PWR Green Solid Device powered On e Sync Button Changes the default encryption key Power Off 4 Off evice powere e Reset Button
39. uccessful you will receive a message indicating that all Powerline adapters were added to your network verifying that the encryption key was changed for all Powerline adapters Click OK Setting the network name on the devices whose password has been LE entered This may take few seconds Click on Ok button Cancel 19 TRENDnet User s Guide TPL 306E TPL 306E2K To rename the Powerline adapters Note Renaming the Powerline adapters Remote devices to describe the location of the device will help you to easily identify which Powerline adapter you are monitoring in the utility 1 In the Powerline Utility Main window select one of the Powerline adapters listed under Remote Device d Powerline Devices detected Network Type Public Autoscan On Device Name Password Quality Rate Mbps MAC Address i Device 4 UU 132 00 DO 90 47 15 84 88 Q Device 7 mum 152 00 00 90 47 1F 1A B5 2 Click Rename Rename 3 The device name field will be available to edit Copyright 2012 TRENDnet All Rights Reserved Upgrade Firmware Note The firmware can only be upgraded when your computer is directly connected to the Powerline adapter Ethernet port also called network port using an Ethernet cable also called network cable The Device Password DPW is not required when upgrading the firmware 1 To check if firmware updates are available for your Powerline adapter check your P
40. uide vou through the steps required to install TRENDnet Powerline Utility on your computer WARNING This computer program i protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the mas mum extent possible under the law 12 In the License Agreement window check the radio button I Agree and click Next e l TRENDnet Do ar ine L IIA za License Agreement Please take a moment to read the license agreement now If you accept the terms below click I Agree then Nest Othemise click Cancel Atheros Communications Inc Software License Agreement PLEASE READ THIS SOFTWARE LICENSE AGREEMENT LICENSE CAREFULLY BEFORE USING THE ATHEROS SOFTWARE BY USING THE ATHEROS SOFTWARE YOU ARE AGREEING TO BE BOUND BY THE TERMS OF THIS LICENSE IF YOU DO NOT AGREE TO THE TERMS OF THIS LICENSE DO NOT USE THE SOFTWARE IF YOU DO NOT AGREE TO THE TERMS OF THE LICENSE YOU MAY RETURN THE ATHEROS SOFTWARE TO THE PLACE WHERE YOU mm a a Em n T 1 Te ee mm tern dn 1 Do Not Agree Copyright 2012 TRENDnet All Rights Reserved 13 In the Select Installation Folder window click Next FID Kaka Select Installation Folder The installer will install TREND net Powerline Utility ta the following folder Ta install in this folder click Next To insta
41. ustomer contained in stored on or integrated with any products returned to TRENDnet pursuant to any warranty There are no user serviceable parts inside the product Do not remove or attempt to service the product by any unauthorized service center This warranty is voided if i the product has been modified or repaired by any unauthorized service center ii the product was subject to accident abuse or improper use iii the product was subject to conditions more severe than those specified in the manual Warranty service may be obtained by contacting TRENDnet within the applicable warranty period and providing a copy of the dated proof of the purchase Upon proper submission of required documentation a Return Material Authorization RMA number will be issued An RMA number is required in order to initiate warranty service support for all TRENDnet products Products that are sent to TRENDnet for RMA service must have the RMA number marked on the outside of return packages and sent to TRENDnet prepaid insured and packaged appropriately for safe shipment Customers shipping from outside of the USA and Canada are responsible for return shipping fees Customers shipping from outside of the USA are responsible for custom charges including but not limited to duty tax and other fees WARRANTIES EXCLUSIVE IF THE TRENDNET PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE THE CUSTOMER S SOLE REMEDY SHALL BE AT TRENDNET S OPTION REPAIR OR REPLACE
42. yption key on the first Powerline adapter 5 Push and hold the Sync button on the second Powerline adapter for 2 seconds and release it The Power PWR LED will start blinking This will create a connection between both Powerline adapters using the new encryption key All LEDs will turn off and turn back on and the Powerline PL LED will turn on the when adapters are connected Copyright 2012 TRENDnet All Rights Reserved Add adapters using the Sync button If you have changed the default encryption key assigned to your Powerline adapters additional adapters will not automatically connect to your Powerline network after they are plugged into a wall power outlet For any additional adapters you will need to reconfigure any additional Powerline adapters that you add to use the encryption key of your existing Powerline network 1st Adapter 2nd Adapter Modem Router Ethernet Ethernet Additional Adapter mmm Electrical Wiring Powerline Network Ethernet TRENDnet User s Guide TPL 306E TPL 306E2K To reconfigure an additional Powerline adapter to connect and use the encrvption kev of vour existing Powerline network 1 Verifv that all existing Powerline adapters are alreadv installed and connected 2 Push and hold the Svnc button on the additional Powerline adapter for 10 seconds and release it All LEDs will turn off and turn back on This will erase the current encrvption kev assigned to the addition
Download Pdf Manuals