Home
Thermador C271 Oven User Manual
Contents
1. The conduit cable where connected at the oven swiv els Rotate conduit cable upward or downward and direct through hole prepared in cabinet to attach to J Box To facilitate service the flex conduit must not be shortened and should be routed to permit temporary removal of the oven SGC304R SGC365R SGC456R SGCS304R SGCS365R SGCS456R SGS36G Steel top gas CD365 CD456 Glass Ceramic top gas and electric Fig 4 TMH Models Installation Minimum Wall Clearance Combustible Wall Countertop Cooktop Minimum Distance to Combustible Wall 3 7 6 cm 2 7 8 7 3 cm 3 3 4 9 5 cm GROUNDING IMPORTANT Local Codes might vary installation electrical connections and grounding must comply with all applicable local codes 2 5 cm 2 3 4 7 0 cm 2 5 cm If local codes permit grounding through the electrical supply neutral connect both the white neutral wire to the bare ground wire from the oven to the white neutral electrical supply wire 2 If local code requires a separate ground connect the white oven neutral wire to the white neutral electrical supply wire and the bare ground oven wire to the bare ground electrical supply wire Page 6 208V ELECTRICAL HOOKUP Applies to C271 C272 C301 C302 CM302 and CJ302 models only Your oven has been preset to be hooked up to 240V Turn off the oven s 2 Open the upper oven door 3 Press and hold the UPPER OFF pa
2. Cutout E Height F Width G Depth H 28 1 4 28 1 2 24 4 3 4 to 3 1 3 8 28 5 8 29 3 4 23 7 8 22 71 8 cm 72 4cm 61 0cm 12 to 79 7 cm 72 7 cm 75 6 cm 60 6 cm 55 9 cm 30 Built In Electric Double Wall Oven CJ302 Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth H 45 5 8 28 1 2 24 15 1 4 46 29 3 4 23 7 8 22 115 9 cm 72 4 cm 61 0 cm 38 7 cm 116 8 cm 75 6 cm 60 6 cm 55 9 cm Add 1 16 for stainless steel ovens S Series Ovens Only Add 1 8 for stainless steel ovens S Series Ovens Only Measured from cabinet face largest door Page 4 Fig 3 Cabinet Cutout 30 Single Oven Under the Counter Installation 2 Cooktop Cutout See Cooktop Installation Instructions Figure 3b Frame Overlap 3 8 1 0 cm Cabinet Figure 3d 3 7 6 cm minimum J Box Conduit N wi iW 0 Exposed Edge Must be a Finish Cut SK A 28 1 2 72 4 cm FRONT VIEW Under the Counter Units A single oven S301 SC301 C301 or CM301 installed under the counter allows for the installation of most Thermador Gas or Electric non Cook n Vent Model Cooktops See Table for recommended cooktop models Downdraft units canno
3. Oo One 2 Piece Broiler Pan Care amp Use Manual Installation Instructions Bottom Trim Installation Screws Packet Quick Guide Cookbook C CJ and CM models only STEP 2 CABINET PREPARATION The cabinet cutout dimensions for wall mounted and under the counter installations are shown in Figs 2 and 3 respectively It is good practice when oven is installed at the end of a cabinet run adjacent to a perpendicular wall or cabinet door to allow at least 1 4 space between the side of the oven door and the wall door Wall Mounted Units For oven support install 2 x 4 s extending front to back flush with the bottom and the side of the opening The supporting base must be well secured to the floor cabinet and level with the floor line Fig Oven Base Attachment Remove Screws 4 places The bottom trim is shipped wrapped in waxed paper on top of the unit and should not be unpacked until the final step when the oven has been placed in the cabinet See Fig 6 NOTE The conduit box for double ovens S272 C272 SCD272 S302 SC302 SCD302 C272 C302 CM302 CJ302 SMW272 and SM272 should be located above the unit to facilitate connecting and servicing For single ovens S301 SC301 C271 C301 and CM301 the conduit box may be installed either above or below the unit If the conduit box is installed below the unit a 2 diameter hole or space is required between the back wall and the right rear
4. INSTALLATION INSTRUCTIONS FOR THERMADOR BUILT IN ELECTRIC OVENS Models C272 C302 CM302 Cj302 C271 C301 CM301 272 SC272 SCD272 S302 SC302 SCD302 S301 SC301 SMW272 SM272 I i iy im i Please read this entire instruction manual before proceeding IMPORTANT Local codes vary Installation electrical connections circuit breakers and grounding must comply with all applicable codes Save these instructions for the Local Electrical Inspector s use INSTALLER Please leave these Installation Instructions with this unit for the owner OWNER Please retain these instructions for future reference WARNING Disconnect power at the breaker before installing Thermadar TABLE OF CONTENTS STEP 1 UNPACKING STEP 2 CABINET PREPARATION STEP 3 ELECTRICAL INSTALLATION STEP 4 INSTALLING THE OVEN STEP 5 INSTALLING THE BOTTOM TRIM STEP UNPACKING Cut the bands from the carton Carefully remove the carton fillers and all packing material Included with your new Thermador oven are the following Number of Racks Per Oven Model C272 C302 CM302 CD272 SCD302 C272 SC302 272 S302 C 302 C301 C271 C301 CM301 SMW272 SM272 301 NW Hh UOW
5. d ina double oven or the OFF pad in a single oven 4 While the UPPER OFF pad or the OFF pad is held down press the CLEAN pad Fig 5 Removing the Door Note Removing the door for installation reduces the weight of the oven by 30 Ibs 14 kg per door STEP 4 INSTALLING THE OVEN CAUTION DO NOT MOVE OR LIFT OVEN BY DOOR HANDLE DOOR GLASS BREAKAGE MAY OCCUR CAUTION THE DOOR OF THE CM301 AND THE UPPER DOOR OF THE CJ302 AND CM302 ARE NOT REMOVABLE For ease of installation some oven door s may be re moved to reduce the weight of the oven by 30 pounds per door To remove the door open the door and hold it all the way open Close the hinge latches See Fig 5 The door can now be removed by gently lifting and pulling the door including the hinges up and out of the frame IMPORTANT Reinstall the door very carefully Be certain that the hinge arm does not hit the porcelain collar around the clearance slot or it will chip the porcelain Page 7 5 240 will appear in the temperature digits Release all pads 6 Touch CLEAN and 208 replaces 240 in the tempera ture digits This will toggle with touches of the Clean pad 7 To complete the change touch UPPER OFF or OFF Note When power is first supplied to the unit and the door is unlocked the CLOCK will flash Set Time of Day as described in the Care and Use Manual If the door is locked the LOCK symbol will light for a few seconds while door is automat
6. e a 3 4 2 cm space from one vertical edge of the door to the adjacent edge of the other door Do not install a cabinet wall partition between the two ovens Table Under The Counter Installation with Thermador Cooktops Model Number Type of Cooktop CER30 CE304 CE365 CE456 Glass Ceramic top electric Model Number Type of Cooktop CGX304 CGX365 CGX456 Glass Ceramic top gas TMH30 TMH36G TMH45P Steel top electric coil GGS30 GGS365 Glass top gas See Figure 4 STEP 3 ELECTRICAL INSTALLATION All model ovens on the front cover are dual rated designed to be connected to either 20 240V AC or 120 208V AC 60 Hz 4 wire single phase power supply The S301 and SC301 require a 20 amp circuit The C271 C301 CM301 SMW272 and SM272 require a 30 amp circuit The 272 SC272 SCD272 C272 302 SC302 SCD302 and C302 require a 40 amp circuit The CM302 and CJ302 require a 50 amp circuit The electrical supply should be a 4 wire single phase AC Install a suitable conduit box not furnished as shown in Figures 2 or 3 Electrical connection Connect the red oven wire to the red electrical supply wire hot wire 2 Connect the black oven wire to the black electrical supply wire hot wire 3 Connect the white neutral oven wire to the white neutral not bare ground electrical supply wire 4 Connect the bare ground oven wire to the bare ground electrical supply wire
7. es for use in Canada Check with your local Canadian distributor or dealer Thermador 5551 McFadden Avenue Huntington Beach CA 92649 For the most up to date critical installation dimensions by fax use your fax handset and call 702 833 3600 Use code 8030 Thermador 5551 McFadden Avenue Huntington Beach CA 92649 800 735 4328 ECO 12582 16 10 988C 2000 BSH Home Appliances Corp Litho Date 6 01
8. ically unlocking and CLOCK will flash Hinge Arm To Unlatch and Close Position of Hinge Latch to remove door After installing the unit replace the door s be certain both hinge arms are well inserted and secure and that the hinge latch is fully released Anchor flexible metallic conduit to conduit box with suitable box connector Connect power supply leads to oven conduit supply leads being sure that neutral wire is connected to white wire Remove the bottom trim from the top of the unit Remove the base skid See Fig Slide the oven into the opening being careful not to scratch side trims Secure oven with the screws supplied through the side of the front frame into the cabinet Note To secure the oven to the cabinet use the 4 screws provided 2 each side STEP 5 INSTALLING THE BOTTOM TRIM Install the bottom vent trim and se cure with 2 screws provided one at each top end corner of the trim The sheet metal bottom of the oven should be under the trim except for the section at the center To install the screws open the door The holes are visible at each end below the left and right hinges Place and tighten screws See Fig 6 View A i Fig 6 Installing rama i Bottom Trim Thermador reserves the right to change specifications or design without notice Some models are certified for use in Canada Thermador is not responsible for products which are transported from the United Stat
9. of the 2 x 4 supports See Fig 2 When an oven is installed the cabinet base must be capable of supporting the oven weight as listed below Oven S series Single Oven C series Single Oven CM Single Oven S series Double Oven C series Double Oven CM C Double Oven Page 2 Fig 2 Cabinet Cutout Wall Mounted Installation FRONT VIEW SIDE VIEW G Double Oven Preferred Location of Location Conduit Box of Conduit C Frame Pox f Overlap i Top 3 8 1 0 cm Cabinet 2 1 2 6 4 cm Above Unit 2 Diameter Hole 4 5 cm 2x4 I Wall Stud Exposed Edge Must Post Supports be a Finish Cut CONDUIT BOX IS NOT FURNISHED WITH UNIT Required Near Back 2 l H Side Frame Overlap Approx 5 13 cm 5 8 Cabinet eas 7 1 6 cm Conduit Box May be Placed Here Recommended Refer to dimensions for specific ovens on Page 4 Page 3 Fig 2 Cabinet Cutout Wall Mounted Installation 27 Built In Electric Double Wall Ovens C272 272 SC272 SCD272 Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth 51 1 8 25 1 2 24 9 3 4 51 1 2 26 3 4 23 7 8 129 9 cm 64 8 cm 61 0 cm 24 8 cm 130 8 cm 68 0 cm 60 6 cm 55 9 cm 27 Built In Electric Single Wall Ovens C271 Cabinet Cutout Dimen
10. sions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth Hes Door 2 28 1 4 25 1 2 24 4 3 4 to 31 3 8 28 5 8 26 3 4 23 7 8 71 8 cm 64 8 cm 61 0cm 12 I to 79 7 cm 72 7 cm 68 0 cm 60 6 cm 55 9 cm 27 Built In Electric Wall Ovens SMW272 Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth 55 3 8 25 1 2 24 9 3 4 55 3 4 26 3 4 23 7 8 140 6 cm 64 8 cm 61 0 cm 24 8 cm 141 6 cm 68 0 cm 60 6 cm 27 Built In Electric Wall Ovens SM272 Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth 45 3 4 25 1 2 24 19 1 2 46 1 8 26 3 4 23 7 8 116 2 cm 64 8 cm 61 0 cm 50 cm 117 cm 68 0 cm 60 6 cm 55 9 cm 30 Built In Electric Double Wall Ovens C302 CM302 S302 SC302 SCD302 Excluding CJ302 See below Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to Cutout E Height F Width G Depth H poor 51 1 8 28 1 2 24 9 3 4 51 1 2 29 3 4 23 7 8 129 9 cm 72 4 cm 61 0 cm 24 8 cm 130 8 cm 75 6 cm 60 6 cm 55 9 cm 30 Built In Electric Single Wall Ovens C301 CM301 S301 SC301 Cabinet Cutout Dimensions Overall Dimension A Height B Width C Depth D Floor to
11. t be installed in this configuration Thermador overhead ventilation is recommended A Thermador cooktop should be installed on the same center line as the under the counter single oven Follow the installation instructions provided with cooktop for installation of cooktops Three 3 inches 7 5 cm minimum is required from the top of the countertop to the top of the cutout opening see Figure 3d for under counter installation with Thermador cooktops see Table Page 6 If the type of cabinet or countertop thickness does not provide for this minimum space the cabinet base may have to be lowered into the toe space to provide the necessary space above the oven Page 5 Frame Overlap typ 5 8 cabinet N ne f 4 a 2 cm Nominal Toe Space SIDE VIEW 2x4 Wall Stud 1 5 cm Supports Some TMH cooktops require additional clearances to combustible walls Refer to Fig 4 for specific models and dimensions NOTE The Thermador Oven Models S301 SC301 C301 or CM301 under the counter and cooktop combination area UL and CUL approved installation Side by side installation units The minimum distance required for side by side installation is 2 inches 5 cm from one vertical edge of the cabinet cutout to the adjacent edge of the next cabinet cutout Use only Thermador Trim Piece D30SXSB black or D30SXSW white for side by side installation in place of the standard cabinet face between the 2 ovens This will leav
Download Pdf Manuals
Related Search
Related Contents
Installation and Operating Instructions Copyright © All rights reserved.
Failed to retrieve file