1. Tektronix 80A03 TekConnect Probe Interface Module CHB USE P7000 SERIES PROBES ONLY SAMPLING MC PROBE POWER 500 fOLTAGE LIMITE Figure 1 The 80A03 TekConnect Probe Interface Module The 80A03 TekConnect Probe Interface Module also allows you the flexibility of using the interface as a general purpose sampling module extender cable by simply disconnecting the short semi rigid cables on the front panel of the interface and using the sampling module inputs directly The TekConnect Probe Interface Module supports probe interface conversion between CSA8000 and TDS8000 Series sampling oscilloscopes and the following TekConnect probes Supported TekConnect probes Dynamic Range P7225 As reported on the probe label P7240 P7260 P7330 P7350 P7350SMA P7380 1 5 Vpk pk 5X 6 Vok pk 25x P7380SMA 1 Vok pk 2 5 5 Vok pk 1 2 5 1 This differs from the probe label See the probe label for actual limits 80A03 TekConnect Probe Interface Module Instruction Manual 1 Getting Started The following electrical sampling modules are recommended for use with the TekConnect Probe Interface Module Recommended Tektronix Description sampling modules 80 011 Single channel 50 GHz 80 022 Dual channel 12 5 GHz 80 032 Dual channel 20 GHz 80E042 Dual Channel 20 GHz with TDR 80 06 Single channel 70 GHz 1 Requ
2. Refer to Table 3 for a list of equipment you need to implement the triggering setups Table 3 Recommended equipment for triggering setups To trigger only Tektronix CSA8000 or TDS8000 Series sampling oscilloscope Tektronix 80A03 TekConnect Probe Interface Module Tektronix 80E02 80E03 or 80E04 electrical sampling module To trigger and view a signal Tektronix CSA8000 or TDS8000 Series sampling oscilloscope Tektronix 80A03 TekConnect Probe Interface Module Tektronix 80E02 80E03 or 80E04 electrical sampling module 80A03 TekConnect Probe Interface Module Instruction Manual Operating Basics Table 3 Recommended equipment for triggering setups cont To trigger only To trigger and view a signal Compatible TekConnect probe Compatible TekConnect probe See page 1 See page 1 1 SMA cable 0 5 3 SMA cables 0 5 Torque wrench SMA 5 16 8 in Ib Torque wrench SMA 5 16 8 in lb 1 6 dB power divider 1 Tektronix part number 174 1427 00 2 Tektronix part number 015 0565 00 Triggering CSA8000 and To set up the TekConnect Probe Interface Module to trigger CSA8000 and TDS8000 Series 7058000 Series Oscilloscopes do the following Oscilloscopes 1 Remove the semi rigid cable that connects the CH B TekConnect Probe Interface Module to the sampling module See Figure 8 Figure 8 Removing the semi rigid cable 2 Use a 0 S SMA cable to connect the CH Te
3. 1 Figure 11 Setup for triggering the sampling oscilloscope and viewing signals using the 80A03 TekConnect Probe Interface Module Figure 12 80A03 replaceable parts Table 1 80A03 features and standard accessories Table 2 Recommended equipment for performing a functional check 66 OES Table 3 Recommended equipment for triggering setup Table 4 Electrical characteristics Table 5 Environmental characteristics Table 6 Physical characteristics 10 15 16 17 18 29 14 23 23 24 80A03 TekConnect Probe Interface Module Instruction Manual a General Safety Summary To Avoid Fire or Personal Injury Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it To avoid potential hazards use this product only as specified Only qualified personnel should perform service procedures While using this product you may need to access other parts of the system Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system Connect and Disconnect Properly Do not connect or disconnect probes or test leads while they are connected to a voltage source
4. Physical 1 Inspecting and Cleaning a ene Wns Troubleshooting ishn he Utd a iva hate nner sae Replacing Parts hh anche ins at E E chara dt ban Repackaging for Shipment 1 Parts Ordering Using the Replaceable Parts List 80A03 TekConnect Probe Interface Module Instruction Manual iii 27 28 Table of Contents List of Figures List of Tables Figure 1 The 80A03 TekConnect Probe Interface Module Figure 2 TekConnect Probe Interface Module inputs and UES Win Sse ALA WNW ake ACH AC RC CAT gc ees Figure 3 Extender cable connection to the sampling oscilloscope wee sos a Ce Figure 4 Installing the sampling module into the TekConnect Probe Interface Module Figure 5 Connecting the sampling module Figure 6 Installing TekConnect probes Figure 7 Equipment setup for functional check Figure 8 Removing the semi rigid cable Figure 9 Setup for triggering the sampling oscilloscope using the 80A03 TekConnect Probe Interface Module Figure 10 Trigger
5. WARRANTY TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES am II Table of Contents Getting Started Operating Basics Reference Specifications Maintenance Replaceable Parts General Safety Summary Service Safety Summary Contacting Tektronix The TekConnect Interface Standard Optional AccessorieS Installing the TekConnect Probe Interface Module Performing a Functional Check Calibrating the TekConnect Probe Interface Module Understanding the Controls Triggering the Sampling Oscilloscope Sampling Module Incompatibility Avoiding Damage from Overvoltage Avoiding Damage from Electrostatic Discharge Electrical Environmental characteristics
6. components that are replaceable for the 80A03 TekConnect Probe Interface Module Use this list to identify and order replacement parts The following table describes each column in the parts list Parts list column descriptions indicates the serial number at which the part was discontinued No entry indicates the part is good for all serial numbers Column Column name Description 1 Items in this section are referenced by figure and index numbers to the exploded view illustrations that follow 2 Use this part number when ordering replacement parts from Tektronix 3 and 4 Column three indicates the serial number at which the part was first effective Column four 5 Qty This indicates the quantity of parts used 6 Name amp description An item name is separated from the description by a colon Because of space limitations an item name may sometimes appear as incomplete Use the U S Federal Catalog handbook H6 1 for further item name identification Mfr code This indicates the code of the actual manufacturer of the part Mfr part number This indicates the actual manufacturer s or vendor s part number Abbreviations Abbreviations conform to American National Standard ANSI 1 1 1972 Mfr Code to Manufacturer The table titled Manufacturers Cross Index shows codes names and addresses Cross Index of manufacturers or vendors of components listed the parts list 28 80A03 TekConnect Probe Interface
7. on Always use a wrist strap provided with your instrument when handling sampling modules or making signal connections Wear anti static clothing and work in a static free workstation when using sampling modules 80A03 TekConnect Probe Interface Module Instruction Manual REE Specifications This section lists the electrical environmental and physical characteristics of the 80A03 TekConnect Probe Interface Module Specifications listed in this section are guaranteed unless labeled typical Typical specifications are provided for your convenience and are not guaranteed The electrical characteristics listed in Table 4 are valid when the 80A03 TekConnect Probe Interface Module operates within the environmental condi tions listed in Table 5 on page 23 Table 4 Electrical characteristics Characteristic Description Output Impedance nominal 50 Frequency range typical DC to gt 12 GHz Insertion Loss typical DC to 6 GHz lt 0 4 dB DC to 12 GHz lt 0 6 dB Return Loss typical DC to 6 GHz gt 25 dB DC to 12 GHz gt 20 dB Electrical Delays nominal 0 90 ns Extender Delay nominal 5 us 1 Provided by the sampling module input 2 TekConnect adapter 3 TekConnect adapter to electrical sampling module Does not include probe sampling module extender Table 5 Environmental characteristics Characteristic Description Temperature Range Operating 10 C to 40 C 50 F to 104 F Nono
8. that is connected The Channel button lights the sampling module LED lights and the selected channel on the sampling oscilloscope becomes active b Turn the Vertical scale knob and set the sensitivity to display a waveform similar to the one shown in Figure 7 Turn the Horizontal scale knob to indicate 2 us div 10 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started 6 Verify the channel operation a Verify the LED on the TekConnect Probe Interface Module for the channel under test is Green b On the sampling oscilloscope verify the probe model serial number scale dynamic range impedance and other information by selecting the Utilities gt System Properties gt Probes menu for the channel under test NOTE The sampling oscilloscope displays the first six characters of the TekConnect probe model and truncates the remaining characters For example the oscilloscope will identify a P7350SMA probe as P7350S The impedance value displayed for P7330 P7350 and P7350SMA probes is for single ended configuration The displayed value is one half the value listed on the probe label c On the sampling oscilloscope verify that the extender cable length is listed as 1 meter in the Utilities gt System Properties gt Sampling Modules menu d On the sampling oscilloscope verify that the signal displayed is a square wave of approximately 1 Vp p with a 5 us period Adjust the offset a
9. 1 VANCOUVER WA 98661 BEAVERTON OR 97006 31 Replaceable Parts 32 80A03 TekConnect Probe Interface Module Instruction Manual
10. 892 00 1 SPRING TORSION 0 126 OD 0 094 ID DOOR LEFT 0 018 8X345 RO7SPRG3 DIA MUSIC WIRE 12 15 200 4560 00 1 COVER ELECTRICAL SLOT 0 031 TK1943 200 4560 00 12 16 441 2326 00 1 CHASSIS ASSY MODULE TK1943 441 2326 00 12 17 214 4891 00 1 SPRING TORSION 0 304 X 0 256 X 1 152 EJECT 0 024 8X345 214 4891 00 DIA MUSIC WIRE STANDARD ACCESSORIES Not 174 4857 00 1 CA ASSY SP ELEC SEMI RIGID COAX 0 141 OD PLATED 06009 174 4857 00 shown Not 171 1298 xx 1 MANUAL TECH INSTRUCTION 80A03 80009 171 1298 00 shown 30 80A03 TekConnect Probe Interface Module Instruction Manual Replaceable Parts Manufacturers cross index Mfr code TK6457 2K262 TK1943 0 05 8 345 61935 80009 06009 Manufacturer BEIJING MINGDAR TECHNOLOGY INC BOYD CORPORATION NEILSEN MANUFACTURING INC NORTH STAR NAMEPLATE INC NORTHWEST SPRING MFG CO SCHURTER INC TEKTRONIX INC TENSOLITE COMPANY PRECISION HARNESS AND ASSEMBLY 3000 TRIAX METAL PRODUCTS INC Address RM 213 LUIPU BLDG NO 5 XIAGUANGLI CHAOYANG DISTRICT 6136 NE 87TH AVENUE 3501 PORTLAND RD NE LABEL PRODUCTS 5750 NE MOORE COURT 5858 WILLOW LANE 1016 CLEGG CT PO BOX 750158 14150 SW KARL BRAUN DR PO BOX 500 COLUMBIA HOUSE BLVD 120 1800 SW MERLO DRIVE 80A03 TekConnect Probe Interface Module Instruction Manual City state zip code BEIJING CN PORTLAND OR 97220 SALEM OR 97303 HILLSBORO OR 97124 6474 LAKE OSWEGO OR 97035 PETALUMA CA 94975 0158 BEAVERTON OR 97077 000
11. Connect the probe output to the measurement instrument before connecting the probe to the circuit under test Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement instrument Ground the Product This product is indirectly grounded through the grounding conductor of the mainframe power cord To avoid electric shock the grounding conductor must be connected to earth ground Before making connections to the input or output terminals of the product ensure that the product is properly grounded Observe All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product The common terminal is at ground potential Do not connect the common terminal to elevated voltages Connect the ground lead of the probe to earth ground only Do Not Operate Without Covers Do not operate this product with covers or panels removed Avoid Exposed Circuitry Do not touch exposed connections and components when power is present Do Not Operate With Suspected Failures If you suspect there is damage to this product have it inspected by qualified service personnel Do Not Operate in Wet Damp Conditions Do Not Operate in an Explosive Atmosphere Keep Product Surfaces Clean and Dry 80A03 TekConnect Probe Interface Module Instruction Manual iii Gene
12. Hold down screw Figure 3 Extender cable connection to the sampling oscilloscope NOTE Do not use any additional extender cables to connect the 80 03 TekConnect Probe Interface Module to the sampling oscilloscope 80A03 TekConnect Probe Interface Module Instruction Manual 5 Getting Started Installing the Sampling Module A To install the sampling module into the front panel of the TekConnect Probe Interface Module perform the following tasks CAUTION Sampling modules are inherently vulnerable to static damage Always observe static safe procedures and precautions as outlined in your sampling module user manual 1 Verify that the sampling oscilloscope is powered off if necessary toggle the front panel On Standby switch 2 Insert the sampling module into the front panel compartment of the TekConnect Probe Interface Module as shown in Figure 4 3 Push the module in slowly with firm pressure to seat it 4 Once the module is seated turn the hold down screw to tighten the sampling module in place See Figure 4 5 To release the module later loosen the hold down screw fully and then slide the ejector lever Ejector lever Hold down screw Sampling module Figure 4 Installing the sampling module into the TekConnect Probe Interface Module NOTE To remove the sampling module first loosen the hold down screw the
13. Instruction Manual Tektronix 80A03 TekConnect Probe Interface Module 071 1298 01 This document applies to firmware version 1 00 and above Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety summaries prior to performing service www tektronix com Copyright Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved Tektronix Inc P O Box 500 Beaverton OR 97077 0001 TEKTRONIX TEK and TekConnect are registered trademarks of Tektronix Inc WARRANTY Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one 1 year from the date of shipment If a product proves defective during this warranty period Tektronix at its option either will repair the defective product without charge for parts and labor or will provide a replacement in exchange for the defective product In order to obtain service under this warranty Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service Customer shall be responsible for packaging
14. Module Instruction Manual Replaceable Parts Figure 12 80A03 replaceable parts 80A03 TekConnect Probe Interface Module Instruction Manual 29 Replaceable Parts Replaceable parts list Fig amp index Tektronix Serial Mfr number number effective discontd Qty amp description code Mfr part number 12 1 200 4827 00 1 COVER EXTERIOR AL GOLDEN GATE SAFETY CON TK1943 200 4827 00 TROLLED 12 2 174 4856 00 2 CA ASSY SP ELEC SEMI RIGID COAX 0 141 OD PLATED 06009 174 4856 00 12 3 407 4954 00 1 BRACKET ASSY TEKCONNECT ACQUISITION AL TK1943 407 4954 00 426 2609 00 1 RECEPTACLE PROBE ASSEMBLY 12 4 386 7392 00 1 PLATE STRAIN RELIEF EXTENDER CABLE 386 7392 00 12 5 343 1684 00 1 CLAMP CABLE RETENTION TK1943 343 1684 00 12 6 174 4855 00 1 CA ASSY SP ELEC 28 26 AWG 6 COAX WIRES 39 INCH 06009 174 4855 00 LONG 12 7 348 0430 00 1 BUMPER PLASTIC POLYURETHANE BLACK 2K262 ORDER BY DESCRIPTION 12 8 105 1132 00 1 LEVER EJECT 0 048 THK SST ELECTRICAL HEAD 1943 105 1132 00 12 9 386 7393 00 1 PLATE MOUNTING AL TK1943 386 7393 00 12 10 441 2328 00 1 CHASSIS MAIN ASSEMBLY TK1943 441 2328 00 12 11 671 5711 50 1 CIRCUIT BD ASSY FOR SERVICE ONLY 80009 671 5711 50 12 12 131 6417 00 1 GROUNDING 0 600 L 0 250 W X 0 220 6457 131 6417 00 D ELECTROLESS NICKEL PLATE 12 13 214 4892 00 1 SPRING TORSION 0 126 OD 0 094 ID DOOR LEFT 0 018 8X345 075 3 DIA MUSIC WIRE 12 14 214 4
15. ace Module 18 80 03 TekConnect Probe Interface Module Instruction Manual Operating Basics NOTE Do not connect any other accessory to the sampling oscilloscope Trigger Probe power port Doing so may cause confusion that can lead to measurement errors If you use the sampling oscilloscope Trigger Direct input it is recommended that you Set the trigger level on the oscilloscope to 0 volts With this configuration you can control the trigger level by directly assigning the vertical offset for the CH B probe at the probe tip Because the offset control in the probe affects the signal level at its output this method of vertical offset adjustment provides calibrated trigger level operation To operate the offset control as a trigger level adjustment rotate the offset adjustment on the sampling module channel that has the probe output discon nected This will control the offset at the probe tip and you can read the trigger level directly from the offset indicator on the sampling oscilloscope as shown in Figure 10 NOTE The 2X power divider used in this setup introduces a vertical scale error factor of 2 Sampling Module Incompatibility Due to SMA cable incompatibility you cannot directly use 80E01 or 80 06 sampling modules with the 80A03 TekConnect Probe Interface Module See page 2 for additional information 80A03 TekConnect Probe Interface Module Instruction Manual 19 Operating Basics 20 80A03 TekConn
16. ached The LED remains off indicating that no probe is detected 80A03 TekConnect Probe Interface Module Instruction Manual 13 Operating Basics Triggering the Sampling Oscilloscope Trigger Bandwidth Considerations Recommended Equipment 14 Use the following procedures to set up the 80A03 TekConnect Probe Interface Module to trigger and view signals on CSA8000 and TDS8000 Series sampling oscilloscopes The TekConnect Probe Interface Module supports many models of TekConnect probes Since the trigger bandwidth limit is determined by the probe bandwidth and oscilloscope trigger capability some probes may be more suitable than others to your measurement needs CSA8000 and TDS8000 Series oscilloscopes provide two trigger inputs you can use with external probes direct or prescaled When selecting an input you should consider the frequency of the signal being measured The bandwidth specification of the measurement probe must also meet or exceed that of the signal being measured In addition consider the following factors when setting up equipment to take measurements The oscilloscope trigger sensitivity relative to the amplitude of the signal being measured m The probe scale factor m The attenuation factor of the power divider used if you choose to view signals on the oscilloscope following the trigger NOTE Refer to your sampling oscilloscope documentation for direct and prescaled trigger specifications
17. and shipping the defective product to the service center designated by Tektronix with shipping charges prepaid Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located Customer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than Tektronix representatives to install repair or service the product b to repair damage resulting from improper use or connection to incompatible equipment c to repair any damage or malfunction caused by the use of non Tektronix supplies or d to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TEKTRONIX RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS
18. ect Probe Interface Module Instruction Manual EY Reference This section contains information you may need to take measurements or to avoid damaging the 80A03 TekConnect Probe Interface Module Avoiding Damage from Overvoltage Know your signal source If it is capable of delivering overvoltages it is safer to not depend on the signal source settings for protection but instead use an external attenuator that protects the input from the worst case conditions For example for a 20 V maximum source connected to a 3 V maximum sampling module use a 10X attenuator Where possible connect your cables to the signal source first and to the sampling module second You can use a Tektronix 80A02 EOS ESD Protection Module to protect the sensitive input stage of sampling module from damage due to electro overstress EOS and electro static discharge ESD from the device under test DUT Use the 80A02 in applications such as TDR circuit board testing and cable testing where large static charges can be stored on the device under test Install the 80 02 EOS ESD Protection Module between the device under test DUT and the sampling module When used with the P8018 TDR probe the 80A02 achieves static protection using normal probing procedures no intentional user intervention such as stepping on a foot switch is required This eliminates instrument damage due to human error in coordinating probing with control switching to achieve static prot
19. ection Avoiding Damage from Electrostatic Discharge Circuitry in the sampling module is very susceptible to damage from electrostat ic discharge or from overdrive signals Be sure to only operate the sampling module in a static controlled environment Be sure to discharge to ground any electrostatic charge that may be present on the center and outer connectors of cables before attaching the cable to the sampling module 80A03 TekConnect Probe Interface Module Instruction Manual 21 Reference 22 CAUTION To prevent damage from electrostatic discharge install 50 Q terminations Tektronix part number 015 1022 xx on the sampling module connectors before removing the sampling modules from an instrument or when it is not in use Store the sampling module in a static free container such as the shipping container Whenever you move the sampling module from one instru ment to another use a static free container to transport the sampling module To prevent damage to the sampling module discharge to ground any electrostat ic charge that may be present on the center and outer conductors of cables before attaching the cable to the sampling module To prevent damage to the sampling module do not create an ESD antenna by leaving cables attached to the sampling module input with the other end of the cable open To prevent damage to the sampling module or instrument never install or remove a sampling module when the instrument is powered
20. gger level Counterclockwise rotation introduces a positive offset and a positive trigger level 80A03 TekConnect Probe Interface Module Instruction Manual 17 Operating Basics Triggering and Viewing set up the TekConnect Probe Interface Module to trigger CSA8000 and Signals CSA8000 and TDS8000 Series Oscilloscopes do the following TDS8000 Series Oscilloscopes 1 Remove the semi rigid cable that connects the CH B TekConnect Probe Interface Module to the sampling module See Figure 8 on page 15 2 Use a 0 5 SMA cable to connect the 6 dB 2X power divider to the disconnected CH B SMA connector on the TekConnect Probe Interface Module See Figure 11 3 Use 0 5 SMA cable to connect the disconnected port on the sampling module to one side of the 6 dB 2X power divider See Figure 11 4 Use 0 5 SMA cable to connect the other side of the power divider to the sampling oscilloscope trigger input Trigger Direct or Trigger Prescaled 5 Attach a TekConnect trigger probe to CH B on the TekConnect Probe Interface Module See Figure 11 CSA8000 TDS8000 000000009 00 D Trigger prescaled Trigger direct input input Trigger and Measurement probe 6 dB power PT J divider Circuit under test Figure 11 Setup for triggering the sampling oscilloscope and viewing signals using the 80A03 TekConnect Probe Interf
21. i rigid SMA cables 2 SMA cable 50 Q termination SMA type Torque wrench Recommended example Tektronix CSA8000 or TDS8000 Tektronix 80E02 80E03 or 80E04 Tektronix P7000 Series Tektronix P7225 P7240 015 0678 xx Tektronix P7260 067 1456 xx Tektronix P7330 P7350 067 0419 00 Tektronix part number 174 4857 xx Tektronix part number 174 1427 00 Tektronix part number 015 1022 xx SMA 5 16 8 in lb To verify the functionality of Channel A perform the following tasks 1 Initialize the system a Power on the sampling oscilloscope b Wait for the boot up process to complete c Press the front panel Default Setup button 2 Connect the signal source a On the sampling oscilloscope connect the SMA cable to the Internal Clock Output See Figure 7 on page 10 for details b Connect the Probe Tip Adapter with 50 Q termination to the other end of the SMA cable 3 Set up the trigger system a In the UI application toolbar select Internal Clock from the Trig List menu box 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started 4 Connect the probe a Attach the P7000 Series probe to the Channel A input of the 80A03 TekConnect Probe Interface Module b Install the probe tip onto the probe tip adapter Figure 7 Equipment setup for functional check 5 Set up the channel for test a On the sampling oscilloscope press the channel button to select the channel
22. ies Accessory Description Semi Rigid Cables Consists of two semi rigid SMA to SMA cables for connecting the electrical sampling module to the TekConnect Probe Interface Module Tektronix part number 174 4857 xx Statement of compliance A certificate verifying the product was assembled and verified using Statement of established procedures and work instructions When applicable test equipment is traceable to compliance known standards Included with product at initial shipment This accessory cannot be ordered Instruction Manual Provides instructions for operating and maintaining the 80A03 TekConnect Probe Interface Module Tektronix part number 071 1298 xx Optional Accessories No optional accessories are available for the 80A03 TekConnect Probe Interface Module 80A03 TekConnect Probe Interface Module Instruction Manual 3 Getting Started Installing the TekConnect Probe Interface Module Figure 2 shows the TekConnect Probe Interface Module and locations of the sampling module and probe inputs The extender cable on the rear of the interface connects to the sampling oscilloscope front panel Extender cable Sampling module TekConnect probe input E Semi rigid Figure 2 TekConnect Probe Interface Module inputs and outputs Installing the TekConnect Probe Interface Module consists of the following steps 1 Connecting the Interface Module to the Sampling Oscilloscope 2 Install
23. ing the Sampling Module 3 Installing the Semi Rigid SMA Connector Cables 4 Installing the TekConnect Probe 4 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started Connecting the Interface install the TekConnect Probe Interface Module Extender Cable into the front Module tothe Sampling panel of the sampling oscilloscope perform the following tasks Oscilloscope CAUTION To prevent damage to the sampling module never install or remove a A N module when the sampling oscilloscope is powered on or when either input connector is left unprotected Follow the precautions described in your sampling module and oscilloscope manuals to avoid damage 1 Turn off the sampling oscilloscope using the front panel On Standby switch 2 Install the TekConnect Probe Interface Module Extender Cable connector into any of the small sampling module compartments on the front panel of the sampling oscilloscope See Figure 3 3 Push the module in slowly with firm pressure to seat it 4 Tighten the hold down screw to hold the connector in place To remove the connector later loosen the hold down screw and slide the ejector lever NOTE Installing a large sampling module into a large compartment of the sampling oscilloscope may disable channels on a small module already installed Refer to the documentation for the sampling oscilloscope about compartment interaction CSA TDS8000 sampling oscilloscope
24. ires 2 4 1 85 mm to 2 92 mm SMA adapter Tektronix part number 011 0157 00 standard with these sampling modules Also requires custom cable not available from Tektronix use a short high quality SMA cable or fabricate your own semi rigid cable 2 Recommended for use with 80A03 TekConnect Probe Interface Module The 80A03 TekConnect Probe Interface Module does not support the Tektronix P6209 probe For this probe the interface disables the sampling module inputs There is also no support for TekProbe Level 2 legacy probes that utilize the 1 TCA BNC 75 adapters The TekConnect Interface Power for the 80A03 TekConnect Probe Interface Module sampling module and TekConnect probes is supplied through the cable that connects the TekConnect Probe Interface Module to the sampling oscilloscope The same cable also provides a data and communications path from the probe contact pins through the interface to the oscilloscope Power signal offset and probe characteristic data transfers through this interface When a probe is connected the TekConnect Probe Interface Module reads information from the probe identifies the device and turns on the appropriate power supplies 2 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started Standard Accessories Table 1 lists the 80 03 TekConnect Probe Interface Module features and standard accessories Table 1 80A03 features and standard accessor
25. kConnect Probe Interface Module to the sampling oscilloscope trigger input Trigger Direct or Trigger Prescaled See Figure 9 on page 16 3 Attach the TekConnect measurement probe to CH A on the TekConnect Probe Interface Module See Figure 9 4 Attach TekConnect trigger probe to CH on the TekConnect Probe Interface Module See Figure 9 80A03 TekConnect Probe Interface Module Instruction Manual 15 Operating Basics 16 NOTE Do not connect any other accessory to the sampling oscilloscope Trigger Probe power port or use the disconnected sampling module channel for any other purpose while using this setup Doing so may cause confusion that can lead to measurement errors CSA8000 TDS8000 20 5 0 20 0 a 5 Trigger prescaled Trigger direct input input Circuit under test Measurement probe Figure 9 Setup for triggering the sampling oscilloscope using the 80A03 TekCon nect Probe Interface Module The sampling oscilloscope responds to the CH A probe as though it were connected to the vertical sampling channel The Trigger probe is serviced and controlled by the sampling oscilloscope CH B vertical channel controls The probe scale is not reflected in any trigger level settings assigned by the trigger setup menu The offset control for the vertical channel adjusts the probe offset if equip
26. least one inch greater than the probe dimensions The box should have a carton test strength of at least 200 pounds 2 Put the probe into an antistatic bag or wrap to protect it from dampness 3 Place the probe into the box and stabilize it with light packing material 4 Seal the carton with shipping tape 80A03 TekConnect Probe Interface Module Instruction Manual Replaceable Parts This section contains a list of the replaceable parts for the 80 03 TekConnect Probe Interface Module Use this list to identify and order replacement parts Parts Ordering Information Replacement parts are available through your local Tektronix field office or representative Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements Therefore when ordering parts it is important to include the following information in your order Part number Instrument type or model number Instrument serial number Instrument modification number if applicable If you order a part that has been replaced with a different or improved part your local Tektronix field office or representative will contact you concerning any change in part number 80A03 TekConnect Probe Interface Module Instruction Manual 27 Replaceable Parts Using the Replaceable Parts List This section contains a list of the mechanical and or electrical
27. ling or operating the TekConnect Probe Interface Module try the following troubleshooting procedures To verify the interface module and microcontroller are functioning properly perform the following steps 1 Attach a valid probe to the TekConnect input The LED turns green if the interface module is receiving power and the microcontroller is functioning normally 2 Attach an invalid probe to the TekConnect input The LED turns red if the interface module is receiving power the microcon troller is functioning normally and a probe is being sensed If the LEDs respond normally at power on but no signal is detected by the sampling oscilloscope probe connected check the sampling module and semi rigid cable connections 80A03 TekConnect Probe Interface Module Instruction Manual 25 Maintenance Product Requires Service Replacing Parts The following conditions indicate an internal failure See page vi for information on contacting Tektronix for service No LED activity at power on m LEDs are inactive on a single channel LED response is inconsistent when connecting the same probe alternately to both channels Refer to the Replaceable Parts section on page 27 for a list of customer replacement parts Repackaging for Shipment 26 If the original packaging is unfit for use or not available use the following packaging guidelines 1 Use a corrugated cardboard shipping carton having inside dimensions at
28. n use the ejector lever on the interface module to eject the sampling module 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started Installing the Semi Rigid To provide a signal path between the sampling module and the TekConnect SMA Connector Cables Probe Interface Module perform the following tasks 1 Connect your wrist strap to the antistatic connector on the front of the sampling oscilloscope 2 Use the two semi rigid SMA cables included with this product to connect the TekConnect Probe Interface Module to the sampling module as shown in Figure 5 To obtain proper alignment and mate the SMA connectors you may need to change the bend angle of the center bend It is recommended that you do not change the bend angle by more than 1 8 in NOTE Always use a calibrated torque wrench to install adapters attenuators cables or power sensors any setup Torque all connections to 8 0 3 inch pounds For information on proper installation and torquing techniques refer to your sampling module user manual Figure 5 Connecting the sampling module CAUTION The semi rigid SMA connector cables used on the 80A03 TekConnect Probe Interface Module are not compatible with the input connections of 90 01 80E06 sampling modules Do not attempt to force a connection between the semi rigid connector cables on the TekConnect Probe Interface Module and these sampling modules Use the proper adapter
29. nd verify that the display signal moves vertically to the offset level f Adjust the vertical scale and verify that the displayed signal height changes To verify functionality of the TekConnect Probe Interface Module Channel perform the following tasks 1 Connect the probe to Channel B instead of Channel A 2 Repeat steps 5 through 6 above Functional Checks for verify that the oscilloscope sampling module or TekConnect probe is Other Equipment performing properly run the calibration compensation or functional verification procedure recommended for the individual product For detailed instructions refer to the user manuals that accompanied these products 80A03 TekConnect Probe Interface Module Instruction Manual 11 Getting Started Calibrating the TekConnect Probe Interface Module The 80A03 TekConnect Probe Interface Module requires no internal calibration However after installing any sampling module you should run a compensation procedure from the sampling oscilloscope This ensures that the entire test system meets warranted accuracy specifications with the TekConnect interface and probe attached Refer to your sampling module probe and oscilloscope manuals for specific calibration procedures 12 80A03 TekConnect Probe Interface Module Instruction Manual SEE Operating Basics This section contains information you need to operate the 80A03 TekConnect Probe Interface Module Understanding the C
30. ontrols The 80A03 TekConnect Probe Interface Module front panel has one multi color LED for each channel During power on and normal operation the LEDs report red green or off as explained below The TekConnect Probe Interface Module contains no additional user controls Power On Status Probe Status Red Indicates that an incompatible probe is attached to the TekConnect input See page 1 for a list of compatible probes Green Indicates that a supported probe is attached to the TekConnect input Off Indicates that the probe interface is disconnected from the sampling oscilloscope no power or that a probe is not attached to the TekConnect input The following describes typical TekConnect Probe Interface Module operation when you power on the sampling oscilloscope with the probe interface installed Both LEDs flicker green then red then green and turn off This indicates that proper power is applied and initialization has occurred The LEDs do not light This indicates that the probe interface is not receiving power and may be disconnected from the sampling oscilloscope The following describes typical TekConnect Probe Interface Module operation when you attach a TekConnect probe The LED turns green indicating that a valid probe is attached If you pressed the oscilloscope channel button the display also becomes active for the channel selected The LED turns red indicating that an invalid or unrecognized probe is att
31. or damage to the sampling module will occur See page 2 for additional information 80A03 TekConnect Probe Interface Module Instruction Manual 7 Getting Started Installing the TekConnect Probe The TekConnect probe features a spring loaded latch that provides audible and tactile confirmation that a reliable connection has been made to the TekConnect Probe Interface Module NOTE It is not necessary to power off the sampling oscilloscope when removing or installing a TekConnect probe To connect a TekConnect probe to the TekConnect Probe Interface Module perform the following tasks 1 Slide the probe into the TekConnect receptacle on the TekConnect Probe Interface Module The probe snaps into the TekConnect Probe Interface Module when fully engaged See Figure 6 2 To release the probe from the TekConnect Probe Interface Module grasp the compensation box press the latch button and pull out on the probe Latch button Figure 6 Installing TekConnect probes 80A03 TekConnect Probe Interface Module Instruction Manual Getting Started Performing a Functional Check To verify that the 80 03 TekConnect Probe Interface Module is functioning properly perform the following procedure Refer to Table 2 for a list of recommended equipment Table 2 Recommended equipment for performing a functional check Item description Sampling oscilloscope Sampling module TekConnect probe Probe tip adapter Sem
32. ped The sampling module offset control is disabled 80A03 TekConnect Probe Interface Module Instruction Manual Operating Basics You can view probe characteristics in the system properties menu for the measurement channel If you use the sampling oscilloscope Trigger Direct input it is recommended that you set the trigger level on the oscilloscope to 0 volts and control the trigger level by directly assigning the vertical offset for the probe at the probe tip Because the offset control in the probe affects the signal level at its output this method of vertical offset adjustment provides calibrated trigger level operation To operate the offset control as a trigger level adjustment rotate the offset adjust on CH B This will control the offset at the probe tip so you can read the trigger level directly from the offset indicator on the sampling oscilloscope See Figure 10 ajz fa A z 7 Pulse sano tn nn E 5 14 3 100 0 4 a 200 orn BH 6 6 Eco 000ps7 B1 500ns 7 23 PM 4 10 03 Read trigger level from vertical offset value Figure 10 Trigger offset indicator NOTE Rotation of the control knob for this configuration is reversed Clockwise rotation introduces a negative offset adjustment which provides a negative tri
33. perating 22 C to 60 C 7 6 F to 140 F Humidity Operating 20 to 80 RH noncondensing Nonoperating 5 to 90 RH noncondensing 80A03 TekConnect Probe Interface Module Instruction Manual 23 Specifications 24 Table 5 Environmental characteristics cont Characteristic Altitude Operating Nonoperating Mechanical Shock Description 3 048 m 10 000 ft 12 190 m 40 000 ft 50 g half sine 11 ms Table 6 Physical characteristics Characteristic Weight Dimensions Cable Length nominal 1 Description 2 04 kg 4 5 Ibs Height 110 mm 4 250 in Width 70 mm 2 750 in Depth 42 mm 1 625 1 3 28 ft Does not include accessories and shipping container 80A03 TekConnect Probe Interface Module Instruction Manual Maintenance This section contains information you can use to clean and maintain your equipment Inspecting and Cleaning A Troubleshooting Power On Indicators No Signal Detected Remove accumulated loose dust from the TekConnect Probe Interface Module and sampling module with a soft cloth or brush Remaining dirt may be removed with a soft cloth dampened with a mild detergent and water solution or use isopropyl alcohol Do not immerse any equipment in cleaning solutions or use abrasive cleaners CAUTION To prevent damage avoid using cleaning materials that contain acetone benzene toluene xylene or similar solvents If you encounter problems instal
34. ral Safety Summary Symbols and Terms A A Terms in this Manual These terms may appear in this manual WARNING Warning statements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediately accessible as you read the marking CAUTION indicates a hazard to property including the product Symbols on the Product The following symbols may appear on the product CAUTION Refer to Manual 80A03 TekConnect Probe Interface Module Instruction Manual SS Service Safety Summary Only qualified personnel should perform service procedures Read this Service Safety Summary and the General Safety Summary before performing any service procedures Do Not Service Alone Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present Disconnect Power To avoid electric shock switch off the instrument power then disconnect the power cord from the mains power Use Care When Servicing With Power On Dangerous voltages or currents may exist in this product Disconnect power remove bat
35. tery if applicable and disconnect test leads before removing protective panels soldering or replacing components To avoid electric shock do not touch exposed connections 80A03 TekConnect Probe Interface Module Instruction Manual Service Safety Summary Contacting Tektronix vi Phone 1 800 833 9200 Address Tektronix Inc Department or name if known 14200 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA Web site www tektronix com Sales support 1 800 833 9200 select option 1 Service support 1 800 833 9200 select option 2 Technical support Email techsupport tektronix com 1 800 833 9200 select option 3 6 00 a m 5 00 p m Pacific time amp This phone number is toll free in North America After office hours please leave a voice mail message Outside North America contact a Tektronix sales office or distributor see the Tektronix web site for a list of offices 80A03 TekConnect Probe Interface Module Instruction Manual aa Getting Started The 80A03 TekConnect Probe Interface Module is an adapter that allows you to use TekConnect probes with CSA8000 and TDS8000 Series sampling oscillo scopes 80 sampling modules The interface is comprised of an enclosure that houses a compartment for one 80EOX electrical sampling module and two TekConnect probe inputs The interface connects to the sampling oscilloscope through a permanently attached 1 meter extender cable