Home

Renesas FP-80B Computer Hardware User Manual

image

Contents

1. To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection or removal while making sure not to bend or twist the cable or connectors Otherwise the connectors will be damaged 2 After making sure the direction of the cable body connector is correct firmly insert the cable body connector into the emulator station socket figure 2 RENESAS Figure 2 Connecting User System Interface Cable to Emulator Station RENESAS 2 2 Connecting User System Interface Cable to User System A WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the IC socket apply epoxy resin adhesive to the bottom of the IC socket for an FP 80B package and fasten it to the user system before soldering 2 2 2 Soldering IC Socket
2. After fastening solder the IC socket for an FP 80B package to the user system Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU RENESAS 2 2 3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin 1 on the IC socket for an FP 80B package on the user system with pin 1 on the user system interface cable head and insert the user system interface cable head into the IC socket on the user system as shown in figure 3 2 2 4 1 Fastening Cable Head CAUTION Use a Phillips type screwdriver whose head matches the screw head The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary RENESAS Fasten the user system interface cable head to the IC socket for an FP 80B package on the user system with the four screws M2 x 12 mm with four flat washers provided Each screw should be tightened a little at a time alter
3. ESAS
4. H8 3637 Series FP 80B User System Interface Cable HS3637ECF61H for E6000 Emulator User s Manual 2 CENESAS HS3637ECF61HE Cautions Renesas neither warrants nor grants licenses of any rights of Renesas s or any third party s patent copyright trademark or other intellectual property rights for information contained in this document Renesas bears no responsibility for problems that may arise with third party s rights including intellectual property rights in connection with use of the information contained in this document Products and product specifications may be subject to change without notice Confirm that you have received the latest product standards or specifications before final design purchase or use Renesas makes every attempt to ensure that its products are of high quality and reliability However contact Renesas s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other charact
5. SAS y To emulator station a A Q TS Screws M2 x 12 mm with flat washers Screws M2 x 8 mm i I for fastening cable head with flat washers i bass Cable head User system Figure 1 HS3637ECF61H User System Interface Cable RENESAS Table 1 lists the HS3637ECF61H components Please make sure you have all of these components when unpacking Table 1 HS3637ECF61H Components No Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 80B package 4 Socket cover 1 For installing an FP 80B packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with four flat washers 6 Screws M2 x 8 mm 4 For installing an FP 80B packaged MCU with four flat washers 7 Documentation 1 User s manual for HS3637ECF61H this manual 3 RENESAS Section 2 Connection Procedures 2 1 Connecting User System Interface Cable to Emulator Station MA WARNING Observe the precautions listed below Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST 1 Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned The user system interface cable dedicated to the emulator must be used
6. Subclock input specifications Figure 9 System Clock Oscillator and Subclock Input Specifications 16 RENESAS Section 5 Notice Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU This user system interface cable is specifically designed for the HS3LO8EPI60H emulator Do not use this cable with any other emulator station To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the example in figure 10 Place components so that the cable body and cable head are parallel to the user system Emulator station Cable Cable head is parallel y H to emulator station D Cable head is parallel to user system User system Figure 10 User System Interface Cable Location Example 17 RENESAS The P1 short connector is used for testing Do not remove the inserted jumper pin Figure 11 P1 Short Connector REN
7. ad The dimensions for the user system interface cable head are shown in figure 6 N 45 7 i 4 0 gt 63 5 gt 4 Unit mm Tolerance 0 5 mm Figure 6 Dimensions for User System Interface Cable Head RENESAS 25 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 i m ao Cable head gt IC socket Unit mm User system IC149 080 012 B5 Tolerance 0 5 mm manufactured by YAMAICHI ELECTRONICS Co Ltd Figure 7 Resulting Dimensions after Connecting User System Interface Cable 12 RENESAS Section 3 Installing the MCU to the User System CAUTION Check the location of pin 1 before inserting Use a Phillips type screwdriver whose head matches the screw head The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check t
8. ck 6 and the subclock ow by using the CLOCK command emulator command To use the external clock on the user system as the system clock Select target clock t2 with the CLOCK command emulator command Supply the external clock from the user system to the emulator When a crystal oscillator is inserted into the OSC1 and OSC2 terminals for the system clock the colck is generated by the oscillator circuits shown in figure 9 To input an external clock from the user system input clock pulses satisfying the specifications described in the MCU hardware manual into the OSC1 terminal The system clock 6 frequency is half of the external clock frequency To use the external clock on the user system as the subclock Select target clock sub t with the CLOCK command emulator command Supply the external clock from the user system to the emulator To input an external subclock from the user system input clock pulses satisfying the specifications shown in figure 9 into the X1 terminal The oscillator circuits on the user system interface cable cannot generate external subclock pulses by using the crystal oscillator connected to the user system RENESAS Figure 9 shows the system clock oscillator on the user system interface cable and the subclock input specifications R11MQ Vcc To E6000 emulator R2 2709 0 3 Vcc 0 3 Vcc O0V 55ns max 55ns max OSC1 OSC2 Vcc User System Vcc 3 0 V to 5 0 V System clock oscillator
9. eristics Renesas bears no responsibility for failure or damage when used beyond the guaranteed ranges Even within the guaranteed ranges consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail safes so that the equipment incorporating Renesas product does not cause bodily injury fire or other consequential damage due to operation of the Renesas product This product is not designed to be radiation resistant No one is permitted to reproduce or duplicate in any form the whole or part of this document without written approval from Renesas Contact Renesas s sales office for any questions regarding this document or Renesas semiconductor products Preface Thank you for purchasing this user system interface cable HS3637ECF61H for the Renesas s original microcomputer H8 3637 series The HS3637ECF61H is a user system interface cable that connects an H8 3637series E6000 emulator HS3LO8EPI60H hereinafter referred to as the emulator to the IC socket for a FP 80B package for the H8 3637 series MCU on the user system RENESAS Contents Section 1 Configuration sica soscseadssiesosedoansaedaeiieanis tananed sateanse geauadad sapnanesagnoosavenvonse 1 Section 2 Connection Procedures icpsy2ssconceatstiatsstaanseuedsarevaeyadeaoivsarcensrascanntin tobias 4 2 1 Connecting User System Interface Cable to Emulator Station 0 0 cece eeeeeseereeeeeneeeeee 4 2 2 Connec
10. he location of pin before inserting the MCU into the IC socket on the user system as shown in figure 8 After inserting the MCU fasten the socket cover with the provided four screws M2 x 8 mm with four flat washers Take special care such as manually securing the IC socket soldered area to prevent the IC socket from being damaged by overtightening the screws or twisting the components RENESAS Screws M2 x 8 mm with flat washers Socket cover IC socket 1C149 080 012 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system 14 Figure 8 Installing MCU to User System RENESAS Section 4 Verifying Operation 1 When using the H8 3637 series E6000 emulator HS3LO8EPI60H turn on the emulator according to the procedures described in the H8 3637 Series E6000 Emulator User s Manual HS3008EPI60HE 2 Verify the user system interface cable connections by accessing ports and checking the bus states of the pins If an error is detected recheck the soldered IC socket and the location of pin 1 3 The emulator connected to this user system interface cable supports two kinds of clock sources an emulator internal clock and an external clock on the user system for the MCU clock and subclock For details refer to the H8 3637 Series E6000 Emulator User s Manual HS3008EPI60HE To use the emulator internal clock Select the clock in the emulator station as the system clo
11. nating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components Screws M2 x 12 mm with flat washers Cable head Pin 1 IC socket 1 149 080 012 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Figure 3 Connecting User System Interface Cable to User System RENESAS 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Push the remove jig User system Figure 4 Fastening Cable Body RENESAS 2 3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad footprint for the user system with an IC socket for an FP 80B package IC149 080 012 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad lg 26 00 min a el 21 20 max p 0 80x23 18 40 0 1 0 05 i wia 080 0 05 0 50 0 1 ll i SSS A m a 3 ge 2 xj c 3 E ol N ojo co AN o o Il Lo o LO e N x lt O co ze NV Y il ill Y Unit mm Figure 5 Recommended Dimensions for Mount Pad RENESAS 2 4 Dimensions for User System Interface Cable He
12. ting User System Interface Cable to User System ou ceeeceeeeceseeeceeeeeeeeneeeees 6 22 Installing IG Socket urinere nen Er 6 222 SOMETIME IC SOCK ss2ssscsesenseusdgecsscsdvsess csssedeecsctuvssosseseceaseesecs Ea AEE E AE EE EESE 6 2 2 3 Inserting Cable Head c cc scascssscssessasesinseuessaesbasncnessvscsbessesnsansedoaaascbaseaicesvensacs 7 2 24 Bastening Cable Head ccccvscsiessvssusedies eies seh sacibebbasawctsstecinedsatevasssaeva dD ENES Ene beds 7 22 5 Fastening Cable Body iss cisvsesscacsshessicessccpucenaceveesbascspebsisetesocaiteastdasatessbesenscdeuselaces 9 2 3 Recommended Dimensions for User System Mount Pad ee eeceseeeeeeeeseeeeceseeeeeeeenees 10 2 4 Dimensions for User System Interface Cable Head cei eceseseeecseeeeceseeeceaeeeeeeeeeeeeeens 11 2 5 Resulting Dimensions after Connecting User System Interface Cable eee eeeeee 12 Section 3 Installing the MCU to the User System eee eeeeeeeeeeeeteee 13 Section 4 Verifying Operation cdsssecscsosccerisarcansessavasensancendesesvownd saasancesasndeedaaaers 15 SCHUON S NO UC acne cbse teacsauvaee apseaedeaaed pensnse Herred Fersk un banale hobe ARE 17 ii RENESAS Section Configuration CAUTION Use an 1C149 080 012 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 80B package IC socket on the user system Figure 1 shows the configuration of the HS3637ECF61H user system interface cable for the FP 80B package RENE

Download Pdf Manuals

image

Related Search

Related Contents

OM, 125 B, 125 B X-series, 125 BV X-series, 2007-11  Mode d`emploi général    Ele-BOX(エレボックス) - D  Manual de Usuario Tema: PROCESOS SELECCIÓN  a methodology for tribological examination of  Service Instruction Number SIN2348 Revision K  

Copyright © All rights reserved.
Failed to retrieve file