1. OUTPUT 9 THRU 16 HIGH VOLTAGE HIGH VOLTAGE COMPARTMENT COMPARTMENT PANEL PANEL ed MCS16 20 Master Power Supply Made In USA O Figure 2 MCS Unit Wiring Connector Diagram Figure 3 MCS S and SB Unit Wiring Connector Diagram Table C Recommended Wiring Distances The following are the recommended maximum distances transformer to load and are calculated with a 10 percent voltage drop Ten percent is generally the maximum allowable voltage drop for AC powered devices Distances are calculated in feet values in parenthe ses are meters Input Total VA Wire Gauge Voltage Consumed 20 18 16 24 VAC 10 283 86 451 137 716 218 20 141 42 225 68 358 109 30 94 28 150 45 238 72 50 56 17 90 27 143 43 28 VAC 10 386 117 614 187 975 297 20 193 58 307 93 487 148 30 128 39 204 62 325 99 50 77 23 122 37 195 59 You can use Table D as a guide to determine the necessary wire gauge AWG for vario
2. and operation 2 Pelco Manual C653M D 9 03 DESCRIPTION The MCS Series consists of multi output 24 VAC indoor power supplies These power supplies provide output for 4 8 or 16 cameras from a single source and come in 2 5 10 and 20 amp capacities To compensate for voltage losses over long wire runs 28 VAC outputs are also available on most models The power supplies allow for 120 or 240 VAC line input Higher capacity models can handle pan and tilt and receiver operation in addition to the camera when they are used with integrated systems such as the Spectra dome and Esprit Integrated Positioning System Each output on the MCS S and SB switched Series models features its own LED power indicator and three position switch up 24 VAC center off down 28 VAC The switch lets you individually turn each output off or quickly select between 24 and 28 VAC without reconnecting wires All MCS Series models are available with either glass fuses or self resetting circuit breakers poly switches The following bullets explain the advantages and disadvantages of each type e Glass fuses provide more protection than circuit breakers because they act faster and are more precise However they are designed for one time use and must be replaced when they blow Circuit breakers reset themselves when the fault is corrected which eliminates the need to replace fuses However they react more slowly are affect
3. charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products e Three years on Genex Series products multiplexers server and keyboard e Three years on Camclosure and fixed camera models except the CC3701H 2 C C3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products e Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications Two years on Esprit and WW5700 Series window wiper excluding wiper blades e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid
4. ff CONCRETE WALL MOUNTING HARDWARE NOT SUPPLIE Figure 1 Power Supply Mounting Pelco Manual C653M D 9 03 WARNING Peco A N shall not be liable for any damages re sulting trom incorrect wiring or improper loading of an MCS Series Power Supply A N are equipped for 720 VAC line volt age at the factory If you are using 240 VAC you must change the main fuse fuse models and change the voltage selector switch If 240 VAC power is applied with the selector switch set to 120 VAC the main fuse will blow fuse models or the thermal breaker will open breaker mode s WARNING Units INPUT CONNECTIONS 1 Verify that the on off switch inside the box is OFF On MCS S and SB switched models verify that the switch for each output is at the center OFF position 2 Refer to Figure 2 or 3 Remove the high voltage compartment panel inside the box Set the input voltage selector switch inside the compartment to the appropriate line voltage The switch is set at the factory for 120 VAC line voltage 3 If you are using 120 VAC line voltage go to step 4 If you have a fuse model and are using 240 VAC line voltage remove the 120 VAC fuse from the fuse holder directly above the power switch and install the appropriate fuse refer to Table B Find the fuse in the bag located inside the high voltage compartment Extra fuses are supplied for spares 4 Attach the 120 240 input wi
5. MCS Series Master Power Supply Installation Operation Manual C653M D 9 03 Pelco 3500 Pelco Way Clovis CA 93612 5699 USA www pelco com In North America and Canada Tel 800 289 9100 or FAX 800 289 9150 International Customers Tel 1 559 292 1981 or FAX 1 559 348 1120 IMPORTANT SAFEGUARDS AND WARNINGS Observe the following warnings before installing and using this product 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 11 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture the apparatus does not operate normally or th
6. VAC tap Refer to Table D to deter mine acceptable situations for the 28 VAC tap Perform the following steps to attach 24 VAC devices to the MCS Series Power Supply 1 Pelco Manual C653M D 9 03 Refer to Tables C and D in this manual or the wiring table on the unit s lid to determine the output wiring needed for your devices Refer to Figure 2 or Figure 3 for S and SB models for the proper connector strip connections and do one of the following Regular MCS Models For each device attach one output wire to the COM common terminal Attach the second wire to the appropriate 24V or 28V terminal e S and SB Switched Models For each device attach one output wire to the COM common terminal and the second wire to the 24 28V terminal When you finish the wiring connections double check the installation for safety purposes Power up the unit with the on off switch On MCS S and SB switched models move the switch to the appropriate output voltage position up 24 VAC down 28 VAC to provide power Use a voltmeter to verify that used outputs are at appropriate voltage levels Close the lid and secure it using the 8 32 Phillips screw OUTPUT 1 24 VAC OUTPUT 1 28 VAC OUTPUT 9 28 VAC
7. and is based on the VA rating of each product Table A Product Capacity Power Supply Model MCS16 10 MCS16 20 MCS16 10B MCS16 20B MCS4 2 MCS8 5 MCS16 10S MCS16 20S Product MCS4 2B MCS8 5B MCS16 10SB MCS16 20SB CCD Camera 12 vA maximum 4 8 16 16 DF5 DF5S with camera 3 vA 4 8 16 16 DF8A PDF8 12 vA maximum 4 8 16 16 Indoor Spectra 30 vA 1 4 8 16 Esprit without wiper or IOC IOP 50 vA 2 4 8 INSTALLATION To install an MCS Series Power Supply perform the following steps 1 Punch out the necessary knockouts Two knockout holes are provided on the bottom for either 1 2 inch 1 27 cm or 3 4 inch 1 91 cm conduit fittings for the incoming main power Six knockout holes are provided on the top for either 1 2 inch 1 27 cm or 3 4 inch 1 91 cm conduit fittings for the output 24 28V power 2 Open the lid on the unit by removing the 8 32 Phillips screw 3 Install conduit fittings not provided 4 Determine the location of the unit 5 Refer to Figure 1 Drill holes in the mounting surface two of the mounting holes are inside the unit Use the unit as a template 6 Attach the unit securely with four fasteners not supplied of the appropriate length You can use fasteners up to 5 16 inch 0 80 cm in diameter WALLBOARD P MOUNTING HARDWARE WITH ANCHOR OR TOGGLE BOLT NOT SUPPLIED WOOD SCREW NOT SUPPLIED Gmmm gt
8. e apparatus has been dropped 12 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus WARNING 7o 13 To reduce the risk of shock do not perform any servicing other than that contained in A N reduce the risk of the operating instructions unless you are qualified to do so fire or electric shock do not expose this 14 An ALL POLE MAINS SWITCH with a contact separation of at least 3 mm in each apparatus to rain or pole shall be incorporated in the electrical installation of the building moisture 15 The installation method and materials should be capable of supporting four times the weight of the unit WARNING Fisk of fire do not inter 16 Only use replacement parts Pelco recommends connect outputs 17 After replacing repairing this unit s electrical components conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry The product and or manual may bear the following marks This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit CAUTION This symbol indicates that there are RISK OF ELECTRIC SHOCK A important operating and mainte DO NOT OPEN nance instructions in the literature accompanying this unit Please thoroughly familiarize yourself with the information in this manual prior to installation
9. ed by temperature and are not nearly as accurate the amount of current required to trip one can vary as much as 100 percent Since circuit breaker models do not require fuses and automatically reset themselves after the fault is corrected the breakers are not accessible MODELS T 6 2 5 ER o 9 28 2l fls 5 s lt 5 Ea 9 5 8158 a O 5 3s ERA O a la 23 220 8 so Bo 38 3 8 3 5 8 S SESS as Se g5 3iF 5 8 2 s Model Number O SZO EZ oz O LJO oO oOJaa MCS4 2 4 2 1 120 240 24 0 44 x X x x MCS4 2B 4 2 1 120 240 24 0 44 MCS8 5 8 5 3 120 240 24 28 1 10 0 57 X X x x MCS8 5B 8 5 3 120 240 24 28 1 10 0 57 en MCS16 10 16 10 3 120 240 24 28 2 20 1 15 x X x x MCS16 10B 16 10 3 120 240 24 28 2 20 1 15 abe awe ae MCS16 10S 16 10 3 120 240 24 28 2 20 1 15 X X 16 16 MCS16 10SB 16 10 3 120 240 24 28 2 20 1 15 x x x 16 16 mcsi6 20 16 20 3 120 240 24 28 4 40 2 30 X X x x MCS16 20B 16 20 3 120 240 24 28 4 40 2 30 XIXIXIX IX MCS16 20S 16 20 3 120 240 24 28 4 40 2 30 X X 16 16 MCS16 20SB 16 20 3 120 240 24 28 4 40 2 30 x x x 16 16 Pelco Manual C653M D 9 03 APPLICATION EXAMPLES Table A contains examples of products and the number of units that can be powered by each power supply
10. pply models C653M B 6 00 Changed fuse installation information Updated compliance information C653M C 8 02 Added CE certification Revised mportant Safeguards and Warnings C653M D 9 03 Revised mportant Safeguards and Warnings to advise against interconnecting outputs Revised table of models to show which ones have Class 2 outputs Pelco the Pelco logo Spectra Genex Legacy Esprit and Camclosure are registered trademarks of Pelco Copyright 2003 Pelco All rights reserved
11. res to the flying leads in the compartment with the supplied wire nuts Connect the black wire to the AC line lead Connect the white wire to the AC neutral lead 5 Attach the input ground wire to the stud inside the compartment with the supplied washer and nut 6 Replace the access panel Table B Fuse Determination Table m m a l aol alo oo oo oo oo a a rer rr ANN NN N q nid 9 6 o 6 o 66 66 rr rr r rr 77 72 a N nw nw NINN S S O O O O O O O O O O Line Voltage 2 2 e e e 120 VAC 1A 1A 1 6A N A 3A N A 5A N A 240 VAC 0 5A 0 5A 1A N A 1 6A N A 3A N A N A Model is not equipped with a primary input fuse transformer is protected with thermal breaker MCS4 2B uses a fuse for the high voltage line input and provides breakers for the low voltage output channels OUTPUT CONNECTIONS CAUTION Under A N Night load conditions and high power line input voltage from the utility company output voltage from the power supply 28 VAC taps only may reach 32 VAC This voltage can cause over voltage damage on 24 VAC devices Keep in mind certain devices produce variable loads due to heaters blowers and pan and tilt motion and during mini mum requirements may create a light load condition causing excessive voltage Therefore Pelco recommends using a 28 VAC tap only when the sup plied wire size for the given load causes an unacceptable output voltage on the 24
12. shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 if you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to Pelco 3500 Pelco Way Clovis CA 93612 5699 USA If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco c o Expeditors 473 Eccles Avenue South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C653M 3 99 Original version 5 99 Revisions made because fuses are no longer in a bag but in holders Added weight C653M A 8 99 Added material on the four S and SB switched power su
13. tact the factory for return information Refer to the Warranty and Return Information section of this manual Clean the outer surface of the power supply with a nonabrasive cleaning cloth and anti static cleaner Do not use kerosene or similar substances that may damage the surface SPECIFICATIONS MECHANICAL Cable Entry Knockouts for either 1 2 inch 1 27 cm or 3 4 inch 1 91 cm conduit Fuse Size All Fuse Models All fuses are 5 x 20 mm ELECTRICAL Input Voltage All Models 120 or 240 VAC 50 60 Hz Output Voltage MCS4 2 24 VAC All Other Models 24 28 VAC Required Input Current See Models section Pelco Manual C653M D 9 03 7 Output Fuse Ratings MCS4 2 1A MCS8 5 3A MCS16 10 16 10S 3A MCS16 20 16 20S 3A Output Circuit Breaker Ratings MCS4 2B 9 A MCS8 5B 3A MCS16 10B 16 10SB 3A MCS16 20B 16 20SB 3A Input Connectors Wire nut Output Connectors Input Wire Size Output Wire Size Recommended Wiring Distances GENERAL Construction Finish Environment Dimensions Approximate Unit Weight RATINGS NEMA 1 Screw type barrier strips 12 16 gauge solid wire 12 22 gauge solid or stranded wire See Table C Steel Black polyester powder coat Indoor 16 13 H x 10 86 W x 4 37 D inches 40 97 x 27 58 x 11 10 cm 21 75 Ib 9 87 cm Design and product specifications subject to change without notice PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without
14. to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s liability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise The above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state If a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information 1 Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment
15. us cable distances that provide 24 VAC power Or use it in a reverse fashion to determine the maximum allowable cable distance for a particular wire gauge Table D applies when using 2 conductor copper wire with characteristics similar to West Penn 221 227 unshielded cable Calculations are based on a 10 percent voltage drop generally the maximum allowable drop for AC powered devices The minimum acceptable voltage is calculated as follows 24 0 VAC 02 4 10 21 6 Minimum Acceptable Voltage The minimum acceptable voltage used to create Table D was 21 6 volts Therefore the 24 volt output has an acceptable range from 24 volts down to 21 6 volts the 28 volt output s acceptable range is from 28 volts down to 21 6 volts Pelco Manual C653M D 9 03 Table D Required Wire Gauge Required Wire Gauge Table AWG WIRE f o 28 a oe gt Sa 59 Dist 8 SE S3 BE Pas 89 Se 83 Equipment Loads feet Os 55 EB ES is EX Sa 52 VA 10VA_ 2ova 30VA 40vA va 6ova 7ovA sova sova 100VA 200VA NNN ANNA A re Ga aa za a0 EA faa a Pn ANA AAA AANA NANA AANA RANNNANNNA NANANA NNA RANANNNNNA S N Allowable Wire Gauge AWG Using 24 Volt Tap aa Allowable Wire Gauge AWG Using 28 Volt Tap N A Distance and Load Not Recommended For Any Wire Size Between 12 22 AWG MAINTENANCE There are no user serviceable parts except for the fuses If the transformer in the unit does not work properly con