Home
Patton electronic 2172 Network Card User Manual
Contents
1. ISO IM An ISO 9001 Certified Company USER MANUAL MODEL 2172 CopperLINKT High Speed Ethernet Extenders PE PATTON M ElectronicsTo Part 07M2172 UM SALES OFFICE Doc 03333U2 001 Rev A Revised 10 24 06 301 975 1000 TECHNICAL SUPPORT 301 975 1007 CONTENTS 1 0 1 1 zb vei oR amp w D 2 1 2 2 3 0 3 1 3 2 3 3 4 0 4 1 4 2 5 0 5 1 5 2 A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 Warranty Information sn 4 Gomipliance inerte at oed tete Heec 4 EMG Compliance i s cs ceni tete e tee tad 4 Safety Compliance ceeeecceeeseeeseeteeeeeeeeeeaeeseeeeeaeeseaeeseeeeeaeenaas 4 Radio and TV Interference FCC Part 15 4 Declaration of Conformity seen 5 A foco usitas niis este edu 5 Safety When Working With Electricity 6 General Information 7 Features ui pai a YR EU EORR eer 7 Description cm eroe ee pen Qe ies 7 Installation sens 8 Connecting the Twisted Pair Line Interface 9 Connecting the 10 100Base T Ethernet Interface 11 Connecting POWOL iiti e ERREUR MS 12 Configuration insisesnennennennnnnnnte 12 Configuring the hardware DIP switches 12 Configuring DIP Switch S2 esee 14 Switch S2 1 Symmetric Asymmetric Operation 14 Switches S2 2 and S2 3 D
2. 5 Connector Pinout 1 2 3 4 5 no connection 7 8 11 3 3 CONNECTING POWER external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for The Model 2172 does not have a power switch so it powers up as soon as it is plugged in An external AC or DC power supply is available separately This connec tion is made via the barrel jack on the rear panel of the Model 2172 No configuration is necessary for the power supply See Appendix B for domestic and international power supply and cord options DC power supplied via the power supply jack to the 2172 must meet the following requirements DC power supplied must be regulated 5VDC 5 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2172 has eight DIP switches for configuring the unit for a wide variety of applications This section describes switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the underside of the Model 2172 see Figure 6 12 Figure 6 Removing protective cover Figure 7 on page 13 shows the orientation of the DIP switches in the On and Off po
3. ING e This device contains no user serviceable parts The equipment shall be returned to Patton Electronics for repairs or repaired by qualified service personnel e Mains Voltage Ensure that the external power adapter is a listed Limited Power Source The mains outlet that is utilized to power the devise shall be within 10 feet 3 meters of the device shall be easily accessible and protected by a circuit breaker Ensure that the power cable used meets all applicable standards for the coun try in which it is to be installed and that it is connected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the unit is ON or OFF To avoid electric shock use caution when near WAN ports When detaching the cables detach the end away from the device first Do not work on the system or connect or disconnect cables during periods of lightning activity In accordance with the requirements of council direc tive 2002 96 EC on Waste of Electrical and Electronic Equipment WEEE ensure that at end of life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for one year for parts and labor If any questions or problems arise during in
4. ata Rate 14 Operation 5 eee tecti erii n EEEa ea 16 Power Up idee pube icis 16 Front Panel LED Status Monitors seeee 16 Specifications iiss eerie id 18 LAN Connection seca cud tet a e Re tp i tn Gea Wales Meares 18 Transmission LINE ate e ee 18 CopperLINK Line Rate and CopperLINK Distance 18 CopperLINK Surge Suppressor siseses ninos 18 ED Status Ingdicatots itp tes b att dee decreta 18 PoWer Supply sak see tote f de ppt dece ans 18 Temperature Ranges une imb paria tete tbc ty anpra eu 18 FIUMIGILY aca io ehe eR a T EHE UE 18 DIMENSIONS un de ER peer e oed e E Nr Reiser od o etd 18 Model 2172 Series Factory Replacement Parts and Accessories 19 Model 2172 Series Interface Pin Assignment 20 2 G 1 A0 AGOBase T Interface xxu eoe t te er es 20 A Ente uento ai ete pe Seu ce 20 7 2 CopperLINK IriterfaGe oce er ere metes 20 O 20 Terminal BIGCK 5 42 ii tana 20 D Distance Chart Based on 24 AWG 0 5 MM 21 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 2172 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of the shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fai
5. d twisted pair A 3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE Line Rate 50 Mbps symmetric upstream downstream Additional symmetric and asymmetric rates are available via DIP switch settings Distance 6 000 ft 1 8 km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 21 for details A 4 COPPERLINK SURGE SUPPRESSOR SIDACTOR with maximum current surge 20 kA 8 20 us A 5 LED STATUS INDICATORS Power Green CopperLINK Link Green Ethernet Link Green amp Activity Flashing Green A 6 POWER SUPPLY External AC and DC options AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC Power consumption 450 mA at 5 VDC A 7 TEMPERATURE RANGE 0 50 C A 8 HUMIDITY Up to 90 non condensing A 9 DIMENSIONS 1 58H x 4 16W x 3 75D in 10 6H x 4 1W x 8 8D cm APPENDIX B MODEL 2172 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES Patton Model Description 2172 E CopperLINK Multi Rate 50 Mbps Ethernet Extender No power supply 2172 E 2PK CopperLINK Multi Rate 50 Mbps Ethernet Extender Kit 2 units pre set to local and remote No power supply 2172 EUI 2PK CopperLINK Multi Rate 50 Mbps Ethernet Extender Kit 2 units pre set to local and remote 110 240VAC 07M2172 UM User Manual Power Supplies 08055DCUI 100 240VAC 45V reg DC 2A Universal Input Adapte
6. etric CopperLINK Line Rates Selection Chart S2 2 S2 3 Asymmetric Line Rates DS US ON ON 50 Mbps 2 Mbps ON OFF 16 Mbps 2 Mbps OFF OFF 4 Mbps 1 Mbps Switches S2 4 S2 5 and S2 6 Ethernet Configuration Use switches S2 4 S2 5 and S2 6 to configure Ethernet settings Table 5 Ethernet configurations S2 4 S2 5 S2 6 Ethernet Configurations ON ON ON Auto Negotiate ON ON OFF 100Mb Full Duplex ON OFF ON 100Mb Half Duplex ON OFF OFF 10Mb Full Duplex OFF ON ON 10Mb Half Duplex Switch S2 7 Ethernet Shutdown Use switch S2 7 to enable or disable Ethernet Shutdown When Ethernet Shutdown is enabled the 2172 will disable the Ethernet interface when there is no CopperLINK link detected When Ethernet Shutdown is dis abled the Ethernet interface will always be enabled Table 6 Ethernet Shutdown S2 7 Description ON Ethernet Shutdown Enabled OFF Ethernet Shutdown Disabled Switch S2 8 Remote Configuration Use switch S2 8 to enable or disable Remote Configuration Table 7 Ethernet Shutdown S2 8 Description ON Remote Configuration Enabled OFF Remote Configuration Disabled Note The S2 8 switch applies to the R unit only If enabled the R will follow the dip switch configuration of the L unit If disabled the R unit will use its own dip switch setting to determine its Ethernet 15 operatin
7. g mode and Ethernet Shutdown mode configuration The S2 8 switch does not affect the data rate The data rate will always follow the L configuration 5 0 OPERATION Once the Model 2172s are properly installed they should operate trans parently No user settings required This section describes reading the LED status monitors 5 1 POWER UP Before applying power to the Model 2172 please review section 3 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source 5 2 FRONT PANEL LED STATUS MONITORS The Model 2172 features three front panel LEDs that monitor power the Ethernet signals and the CopperLINK connection Figure 8 shows the front panel location of each LED Table 8 on page 17 describes the LED functions 16 Ethernet LED Link LED Figure 8 Model 2172 standalone unit front panel Table 8 Front panel LED description LED Description PWR Solid GREEN to indicate the unit is powered on LINK Solid GREEN ON to indicate that the end to end CopperLINK link between the Model 2172s is estab lished The Link LED is OFF when the link is down ETH Solid GREEN indicates that 10 100Base T Ethernet link has been established Flashes to indicate activity 17 APPENDIX A SPECIFICATIONS A 1 LAN CONNECTION Shielded RJ 45 10 100Base T IEEE 802 3 Ethernet CopperLINK Connection RJ 45 or Terminal Block A 2 TRANSMISSION LINE Two wire unconditione
8. ill not occur in a particular installation If the equipment causes interference to radio or 4 television reception which can be determined by disconnecting the cables try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 3 DECLARATION OF CONFORMITY We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999 5 EC on the approximation of the laws of the member states relating to Radio and Telecommunication Ter minal Equipment and the mutual recognition of their conformity The safety advice in the documentation accompanying this product shall be obeyed The conformity to the above directive is indicated by the CE sign on the device 1 4 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Services at Tel 1 301 975 1007 Email support patton com URL http www patton com Note Packages received without an RMA number will not be accepted 1 5 SAFETY WHEN WORKING WITH ELECTRICITY A WARN
9. isted Pair LA EN pa 2 wire Y yf Local Remote Network Network Figure 1 Typical application The pair of 2172 models work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application 3 0 INSTALLATION external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for To install the 2172 Ethernet Extender do the following 1 Connect the line interface between the units refer to section 3 1 Connecting the Twisted Pair Line Interface on page 9 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100Base T Ethernet Interface on page 11 3 Connect the power plug refer to section 3 3 Connecting Power on page 12 2172 Terminal block Power jack Ethernet jack Local Remote port switch Ethernet port CopperLINK twisted pair Local Remote RJ 45 interface switch CopperLINK twisted pair terminal block interface Figure 2 Model 2172 standalone rear panel 3 1 CONNECTING THE TWISTED PAIR LINE INTERFACE external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and
10. ls or does not performs as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 COMPLIANCE EMC Compliance FCC Part 15 Class A EN55022 Class A EN55024 Safety Compliance IEC EN 60950 1 AS NZS 60950 1 1 2 RADIO AND TV INTERFERENCE FCC PART 15 This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manu facturer s instructions may cause interference to radio and television reception This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifica tions in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installa tion However there is no guarantee that interference w
11. mechanical serviceability The Interconnecting cables shall be acceptable for The Model 2172 supports communication between two peer Ethernet LAN sites over a distance of up to 6 000 ft 1 8 km over 24 AWG 0 5 mm twisted pair wire Note Actual distance and link performance may vary depending on the environment and type gauge of wire used Follow the steps below to connect the Model 2172 CopperLINK Inter faces Note The Model 2172 units work in pairs One of the units must be configured as a L Local unit and the other unit must be config ured as a R Remote unit It does not matter which end is the L and which is the R The link is always initiated by the R unit As long as the L unit is powered on the R unit can establish a link by being powered on or by having its power reset 1 To function properly the two Model 2172s must be connected together using twisted pair unconditioned dry metal wire between 9 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Model 2172 is equipped with either an RJ 45 or a terminal block interface jack that can be used on the CopperLINK interface These CopperLINK interfaces are a two wire interface Observe the signal pin relationships on the Model 2172 s CopperLINK interface jacks A The Line port has been classified as TNV 1 and is approved for connection to a PSTN TNV 1 circuit WARNING The RJ 45 connecto
12. r 08055 120 5 1 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Adapter 24V PSM 24 VDC Input Adapter 48V PSM 48 VDC Input Adapter Power Cords 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France Belgium Power Cord 0805IN India Power Cord 08051S Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord Only required with optional UI power supply 08055DCUI 19 APPENDIX C MODEL 2172 SERIES INTERFACE PIN ASSIGNMENT C 1 10400BASE T INTERFACE RJ 45 e Pin t TX Pin 2 TX Pin 3 RX e Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block lt RING TIP Figure 1 Model 2172 Terminal Block twisted pair line interface 20 APPENDIX D DISTANCE CHART BASED ON 24 AWG 0 5 MM Symm Line Rate Distance in feet Throughput km at Max Distance 50 Mbps 800 0 25 km 48 25 Mbps 2 000 0 61 km 24 5 10 Mbps 4 000 1 22 km 10 Throughput is Rate n ss feet at Max De DS US 50 Mbps 2 Mbps 2 000 0 61 km 48 2 16 Mbps 2 Mbps 4 000 1 22 km 15 2 4 Mbps 1 Mbps 6 000 1 82 km 3 75 1 Note The actual distance and link performance may vary depending on the environmen
13. r on the Model 2172 s twisted pair interface is polar ity insensitive and is wired for a two wire interface The signal pin rela tionship is shown in Figure 3 1 no connection 2 no connection 3 no connection 4 RING 5 TIP 6 no connection 7 no connection 8 no connection AM Figure 3 Model 2172 RJ 45 twisted pair line interface The terminal block connector on the Model 2172 s twisted pair interface is polarity insensitive and is wired for a two wire interface The signal pin relationships is shown in Figure 4 DE o 0 RING TIP Figure 4 Model 2172 Terminal Block twisted pair line interface 3 2 CONNECTING THE 10 100BASE T ETHERNET INTERFACE external use and shall be rated for the proper applica tion with respect to voltage current anticipated tem CAUTION perature flammability and mechanical serviceability The Interconnecting cables shall be acceptable for The shielded RJ 45 port labeled fhernetis the Auto MDIX10 100Base T interface This port is designed to connect directly to a 10 100Base T network Figure 5 shows the signal pin relationships on this interface You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long 1 TX RX e 2 TX RX __ 3 RX TX 4 no connection 2 TT 6 RX TX Sm 7 no connection 8 no connection Figure 5 Model 2172 10 100Base T RJ 4
14. sitions S2 Front Rear for ON position cS Push toggle down for OFF position Figure 7 DIP switch orientation 13 4 2 CONFIGURING DIP SWITCH S2 DIP switch S2 is where you configure the CopperLINK line rate symmet ric or asymmetric Ethernet and Ethernet Shutdown Table 1 summa rizes default positions of DIP switches S2 1 through S2 8 Detailed descriptions of each switch follow the table Table 1 S2 Summary Position Description S2 1 Symmetric Asymmetric S2 2 Line Rate S2 3 Line Rate S2 4 Ethernet configuration S2 5 Ethernet configuration S2 6 Ethernet configuration S2 7 Ethernet Shutdown S2 8 Remote Configuration Switch S2 1 Symmetric Asymmetric Operation Use switch S2 1 to configure the unit for symmetric or asymmetric opera tion Table 2 Ethernet Auto Sense Selection Chart S2 1 Setting ON Symmetric Operation OFF Asymmetric Operation Switches S2 2 and S2 3 Data Rate Use switches S2 1 S2 2 and S2 3 to configure the CopperLINK line rates Table 3 Symmetric CopperLINK Line Rates Selection Chart S2 2 S2 3 Symmetric Line Rate OFF ON 50 Mbps ON OFF 25 Mbps OFF OFF 10 Mbps 14 Table 4 Asymm
15. stallation or use of this product contact Patton Electronics Technical Support at 1 801 975 1007 2 1 FEATURES Variable rate CopperLINK extender Easy to configure Auto MDIX Ethernet Configurable 10 100 Full Half and Auto Negotiating Ethernet Extends network connections up to 6 000 ft 1 8 km over 2 wire 24 AWG unconditioned lines Switch selectable line rates up to 50 Mbps 6 symmetric or asymmetric settings via DIP switch Transparent operation LED indicators for Power Link and Ethernet Link amp Activity Surge suppression up to 20 kA 8 20 us Made in the USA 2 2 DESCRIPTION The Patton Electronics Model 2172 CopperLink modems provide high speed LAN connections between peered Ethernet LANs remote PC s or any other network enabled 10 100Base T device Operating in pairs one Model 2172 is configured as the L Local unit located at one end of the LAN extension and the other Model 2172 is con figured as the R Remote unit at the other end The Model 2172 is config ured as a Lor R via the switch on the rear panel These units can automatically forward LAN broadcasts multicasts and frames across a 2 wire voice grade twisted pair link The data is passed transparently unmodified through the 2172s The 2172s automatically add and delete MAC addresses only passing packets across the CopperLINK link that are meant for the remote peered LAN 10 100Base TX 10 100Base TX Ethernet Ethernet x Tw
16. t and type gauge of wire used Note DS downstream US upstream 21 Copyright 2001 2002 2006 Patton Electronics Company All Rights Reserved 22
Download Pdf Manuals
Related Search
Related Contents
BA VISUAL de 66312A/6612B Service Manual Delice 5L Star Trac SPINNING 727-0083 User's Manual ADSP-2100 Family User`s Manual, Program Control 信州水環境マップ 2013 P. 2 の取扱説明書がダウンロードできます。 Operating with Beolink 1000 Beolink 1000 Operation CN081 PDF AlvariCRAFT for BreezeMAX TDD User Manual Copyright © All rights reserved.