Home

Parasound HCA-1205A Stereo Amplifier User Manual

image

Contents

1. 10 Power Sources Operate this product only from the type of power source indicated on the label If you are not sure of the type of power supply to your home consult your dealer or local power company This product is equipped with a three prong grounding plug This plug will only fit into a grounding power outlet If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding plug 11 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them 12 Lightning Unplug the unit from the wall outlet for added protection during a lightning storm and when it is left unattended and unused for long periods of time This will prevent damage to the product due to lightning and power line surges 13 Overloading Do not overload wall outlets or extension cords This can result in a fire or electric shock 14 Inserting Objects into Unit Never push objects of any kind into this product through any openings they may touch dangerous voltage points or short out parts that could result in fire or electric shock 15 Servicing Do not attempt to repair or service this product yourself Opening or removing covers may expose you to dangerous voltage and other hazards Refer all servicing to qualified service personnel 16 Damage Requiring Service Unplug thi
2. settings on the amplifier When using the HCA 1205A in a THX installation each level control must be set at maximum to correspond to 0 dB THX reference level Maintaining Your Parasound Amplifier Your Parasound power amplifier requires no periodic maintenance and has no user serviceable parts inside To avoid the risk of electric shock do not remove the top cover The amplifier s exterior can easily be cleaned with a soft cloth moistened only with a few drops of water or glass cleaner Main Power Fuse There is an external fuse located within the AC receptacle that may blow as a result of an internal fault condition This fuse protects the unit from possible damage to internal parts Never replace this fuse with afuse of higher value than installed from the factory Substitution of a larger fuse may create serious stress and damage to internal parts and will void your warranty In Case of Trouble If you suspect a problem with your amplifier first turn the amp off and check all your connections The trouble may be caused by another component or even a defective hookup cable If you are hearing hum out of any of your speakers turn off the amplifier and disconnect the inputs to it If the hum goes away it was probably be caused by your processor or one of the source components connected to it Frequently hum in home theater systems is caused by a grounding problem with the cable TV system Contact your cable provider if necessary to make sur
3. is positive and the ring is negative ground In this case you would terminate one end with an 1 8 mini plug and strip off a 1 4 of insulation and use bare wire on the other end Connect the positive lead to the screw labeled 12 V on the amplifier s DC trigger connector and the negative ground lead to the screw labeled GND With the main power switch in the off down position the amplifier can now be turned on with the external DC source Operating Your HCA 1205A or HCA 855A Power Switch Manual Turn On Press the upper side to turn the unit on manually press the lower side to turn the unit off Automatic Turn On When the power switch is in the off position the power amplifier can be turned on with an external DC voltage applied at the DC trigger connector on the rear panel AC Line LED The AC line LED on the front panel of your amplifier will illuminate whenever AC is present at the AC connector This LED indicates that the AC cord is connected and that power is currently applied to the amplifier Standby Normal Operation LEDs The red Standby LED will light when the amplifier is turned on either with the power switch or an external DC trigger It will stay lit about four to five seconds while the amplifier circuits stabilize After that the red LED will turn off and the green normal LED will signal that the protection relays have switched off and that amplifier is ready to operate The Standby LED will also light whenever there is a
4. short circuit or other fault that triggers the protection circuitry This may indicate one of the following conditions DC present at the amplifier s input a speaker impedance overload a short circuited speaker line or possible internal fault If this LED remains lit remove power to the amplifier and check all connections During this time the protection circuits should automatically reset If the red LED stays lit after you reapply power contact your Parasound Dealer Installer or Parasound Technical Service for further advice Current Overload LEDs The Current Overload LEDs for each channel only illuminates if the unit is driven past its maximum current capacity These LEDs are not clipping indicators but are designed to signal when you are exceeding the limits of your amplifier If these LEDs light it s usually a sign that your speaker impedance is too low resulting in too much current draw from the amplifier s power supply In most imaginable listening situations with recommended loads these LEDs should not illuminate Level Controls Each channel has its own rear mounted set and forget input level control Your amplifier sounds best with these level controls set to maximum where they are effectively out of the audio signal path However if your preamplifier has very high gain and its volume control cannot track properly for left right channel balance near its minimum position it may be necessary to reduce the input level control
5. In the case of anon warranty repair contact us and we will advise you of the repair charges before you ship the unit to us The same packing and RA number requirements apply Parasound HCA 1205A Specifications Continuous Power Output 140 watts RMS x 5 20 Hz 20 kHz 8 Q 200 watts RMS x 5 20 Hz 20 kHz 4 Q Current Capacity 45 amps peak per channel Slew Rate gt 130 V microsecond Power Bandwidth 5 Hz 100 kHz 0 3 dB at 1 watt Total Harmonic Distortion lt 0 03 at full power lt 0 01 typical levels IM Distortion lt 0 03 TIM Unmeasureable Dynamic Headroom gt 1 5 dB Interchannel Crosstalk gt 80 dB at 1 kHz 60 dB at 20 kHz Input Impedance 33 KQ Input Sensitivity 1 V for 28 28 V THX Reference Level 1 2 V for full output S N Ratio gt 117 dB full power gt 96 dB THX reference level Damping Factor gt 800 at 20 Hz Dimensions 17 wide x 5 1 4 high x 19 deep 6 high with feet Power Requirements 110 Vac 120 Vac 1000 Watts Net Weight 46 lb 10 Parasound HCA 855A Specifications Continuous Power Output 85 watts RMS x 5 20 Hz 20 kHz 8 Q 125 watts RMS x 5 20 Hz 20 kHz 4 Q Current Capacity 30 amps peak per channel Slew Rate 130 V microsecond Power Bandwidth 5 Hz 100 kHz 0 3 dB at 1 watt Total Harmonic Distortion 0 03 at full power 0 01 typical levels IM Distortion 0 03 96 TIM Unmeasureable Dynamic Headroom gt 1 5 dB In
6. O W N E R S M A N U A L PARASOUND HCA 1205A Five Channel High Current Power Amplifier HCA 855A Five Channel High Current Power Amplifier Table of Contents Important Safety Instructions virili Rusa CAE Xa anas Cox Ls nid Mae 3 Figure 1 HCA 1205A Front and Rear Panel Drawings ses 4 Figure 2 HCA 855A Front and Rear Panel Drawings eesss 5 ge Polio o MC 6 Installing and Rack Mounting Your Amplifier eeeeeeeeeeeeeeeenerne 6 Ventilation Requirements for Your Amplifier eeeeeereeeeeeeeeeee 6 Making Connections to Your Amplifier eeeeeeeeeereeeeeeeee enne 6 Speaker Connections 7 AC Power Connections and AC Grounding eese 7 DG THQ Ger GONMGCHION EN 8 Operating Your HCA 1205A or HCA 855A cceceeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeseeeeseeeeeeeeeneees 8 Maintaining Your Parasound Amplifier r0cecieeeie iii 9 In Case of Trouble iii 9 Parasound HCA 1205A Specifications 1rrrcccceee eee iii 10 Parasound HCA 855A Specifications rrrceciiee cei iii 11 Special Features for the Parasound HCA 1205A and HCA 855A HCA 1205A Designed by John Curl HCA 1205A THX certified by Lucasfilm L
7. OL ONINUYM TANNOSH3d 39IAH3S QalJrvno OL 9NIDIAH3S 83434 ACISNI SLUYd 318V39IAH3S HISN ON H3AOO 3AOW3H ON OG MOOHS Olu19313 LN3A3Hd OL NOILNYO V cL esnj esnj EBu19 X3 WSN WO oosioue14 ues RI sjonpojg punosesed Jeudi Jamog ua uno YIH e SES VSS8 VOH GND Ae GaNnosvilvd 1066141 90 d e e G jeuueu ndul Q g jouueuo v jauueyo indu y euueuy e e e jauueyo z jeuueuo indu indu jauueyo g jauueyo jauueyo indu Jeuueu DEE J00HS DIHLO3TA 40 VS NOLLNVI Jojoeuuo 4eDDu OPA cL SJ0J UO 9497 pue sj0j9euuo Indu Introduction Congratulations on your purchase of this precision audio component and thank you for your selection of Parasound The Parasound HCA 1205A and HCA 855A five channel amplifiers are virtually identical in operation and sonic performance However the HCA 8554 has slightly less power and is therefore not THX certified like the HCA 1205A Please take a few moments to read these instructions so that you may fully understand the capabilities of your new Parasound power amplifier Unpacking Your Amplifier Carefully unpack your amplifier and remove all the enclosed accessories Be sure to inspect the unit for any possible shipping damage If you see any contact your Parasound Dealer immediatel
8. VSOTI VOH ANNOSVIVd S10 E9Ipu D OUSAaC IUSUnO SJ0 2euuo Jexeeds ejeideoeH OV e pueH Anueg Mm 0001 aren 7H09 AZL OW AYNLSIOW HO NIVH OL LINN SIHL 3SOdX3 LON OQ QHVZVH A N3dO LON 00 E MOOHS HO 200 IN3A3Hd OL JI Leer 1 db TONINESVM NOILNVI TANNOSYSd SOIAYAS G3lsIWWNO OL ONIDIAH3S 83434 30ISNI SLYVd FT9VIIIAHIS HISN ON H3AO9 SAOWSYLON OQ MOOHS 91819913 IN3A3Hd OL NOLINVO t S jeuueyo V eL aen esnj eu19 X3 indui WSN WO oosiougi4j ues 19497 3U S ONpOId punosesed XHL Jeyidury samog Jua dino YBIH e eee VSOZI VOH ONE AZI ANNOSVIVd UJ 10651 ILoa d G jouueu jeuueu z jouueyo indui indui indui Je e1 19497 189497 d Ia XHL p jeuueu Jouueu z leuueu jeuueu PIT wiyseon7 jo J0j2euuo 4966111 OPA ZL O1 U0D ane pue s10 99UUOI INAUI sBuimeig jaued Ia pue 1u0J4 VSS8 VOH E anDi J SJOjeoIpu snjelg 190g YOUMS JOMOd WON gpueis eur OV CT 9 e v S O O O peopano uaung Qa Q 42 ifi duy samog 1u244n 4431H VSS8 VOH ANNOSVIVd JeMOd 1S0d SIO EOIPU peo jeAQ Juan jpe d v y 2v 10 O UUOD 1exeedg a pueH Aue M 0001 uondunsuo2 1amod 2H09 A0ZLOV dHn1SION HO NIVH OL LINN SIHL 3SOdX3 LON OQ QHVZVH MOOHS HO 2017 LN3A3Hd
9. an allow at least six inches on each side and above the amplifier and do not close off the front with a cabinet door or panel 2 If you are enclosing the amplifier within an equipment cabinet use a fan to draw in cool air and exhaust warm air Two vent holes are required one for intake and one for exhaust 3 Do not place the amplifier on carpeting that will obstruct the air flow into the bottom of the amplifier chassis and heatsinks 4 Avoid stacking components If you do stack components you must use a fan to circulate the warm air that will quickly become trapped between them when they are powered on Making Connections to Your Amplifier Leave the AC cord disconnected while making any input or speaker connections When making connections to the amplifier make sure there is no strain or tension on the input leads speaker wires or AC cord that could cause them to pull loose Home Theater Configurations and Input Connections Refer to Figure 1 or Figure 2 Your Parasound multi channel amplifier is designed to deliver the same power and sonic characteristics to the Left Center Right and both Surround speakers of your home theater system For additional low frequency response you should also install a powered subwoofer Even though all the channels of your amplifier operate identically we recommend the following configuration to make it easier to identify each channel in case you ever need to troubleshoot your system Connect the r
10. ature accompanying the product TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Read Instructions Read all the safety and operating instructions before operating this product Retain Instructions Retain safety and operating instructions for future reference Heed Warnings Adhere to all warnings on the product and in the operating instructions Follow Instructions Follow all operating and use instructions Cleaning Unplug this product from the wall outlet before cleaning Use a damp cloth for cleaning Clean the outside of the product only 6 Attachments Do not use attachments that are not recommended by the product manufacturer they may be hazardous 7 Water and Moisture Do not use this product near water 8 Accessories Do not place this product on an unstable cart or stand The product may fall causing bodily injury and damage to the product A product and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the product and cart to overturn 9 Ventilation Slots and openings in the cabinet are provided for ventilation to ensure reliable operation of the product and to protect it from overheating These openings must not be blocked or covered This product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided
11. e the cable feed into your house is properly grounded There are cable isolation devices available such as the Video Link 634 or the Mondial Magic specifically designed to cure this problem In rack mounted systems ground loops and hum can sometimes develop via the metal rack rails of the equipment rack This problem can be solved with nylon shoulder washers mentioned in the rack mounting section of this manual If All Else Fails Call your Parasound dealer or Parasound Technical Service We can suggest other diagnostic tests you can easily perform If we determine that your amplifier should be returned to Parasound or an Authorized Parasound Warranty Center for inspection and possible servicing call Parasound for the location of a warranty center near you If you choose to send it to Parasound contact us to obtain a Return Authorization RA number You will be asked to repack the unit in its original packaging including the additional outer box for protection during transit The Return Authorization number must be clearly marked on the outer carton only You should ship the unit by UPS with adequate insurance and a copy of your purchase receipt to validate your ownership Units that arrive without your specific Return Authorization number without a suitable shipping carton or with evidence of improper internal packing must be refused We do notaccept collect shipments After repair under warranty the unit will be returned to you via prepaid UPS
12. ight front output of your processor to INPUT 1 of your HCA 1205A or HCA 855A Connect the left front output of your processor to INPUT 2 of your HCA 1205A or HCA 855A Connect the center output of your processor to INPUT 3 of your HCA 1205A or HCA 855A Connect the right surround output of your processor to INPUT 4 of your HCA 1205A or HCA 855A Connect the left surround output of your processor to INPUT 5 of your HCA 1205A or HCA 855A Connect the subwoofer output of your processor to the input of your powered sub or sub amplifier Speaker Connections You can connect speaker cables to the amplifier s rear mounted 5 way binding posts using speaker wire terminated with 1 4 spade lugs or banana plugs You can also insert bare wire up to AWG 12 into the holes on the sides of the binding posts If you use bare wire remove only about 1 2 of insulation and twist the wire s strands tightly to prevent strays that could cause a short circuit You may want to tin the stripped wire with solder to prevent it from fraying and oxidizing Polarity When you connect speakers to your amplifier you will notice that one side of the two conductor speaker wire will have some sort of mark either printing a raised ridge on the insulation or a different color of conductor The marked insulation or copper colored wire usually indicates the positive conductor This demarkation lets you know which wire is connected to the positive and which to the negative speaker ter
13. minals so you can do exactly the same on the power amplifier s colored and black binding posts Minimum Impedance Precautions Connect loudspeakers with a 4 Q or 8 Q nominal impedance for normal operation Both amplifiers are capable of driving speakers with occasional impedance dips below 2 Q However sustained high power operation into loads of less than 4 Q may cause overheating and is not recommended AC Power Connections and AC Grounding Before you connect the AC cord make sure your amplifier s power switch is in the off position and the external DC trigger is off If possible plug your amplifier directly to an AC wall outlet Do not connect the amplifierto the accessory AC outlet on your preamplifier or processor because the amplifier s current draw will exceed the rating of most preamplifier s power switches and power cords If you use an external AC line conditioner or surge suppressor make sure it can withstand the power requirements of the amplifier listed in the specification section of this manual DC Trigger Connection The DC Trigger allows you to turn on your amplifier with external DC voltage sources from 9 Vdc to 12 Vdc Use atwo conductor wire such as an 18 AWG speaker wire to connect the DC trigger from an external source to your amplifier You should first determine the DC voltage and ground conductor from the external source For example the AVC 2500 has DC trigger that uses an 1 8 mini jack where the tip
14. s product from the wall outlet and refer servicing to qualified service personnel under the following conditions a If the power supply cord or plug is damaged b If liquid has been spilled into the product c If the product has been exposed to rain or water d If the product does not operate normally by following the operating instructions e If the product has been dropped or damaged in any way f If the product exhibits a distinct change in performance 17 Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer Unauthorized substitutions may result in fire electric shock and other hazards 19 Safety Check Upon completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition 20 Wall or Ceiling Mounting Mount the product to a wall or ceiling only as recommended 21 Heat The product should be situated away from heat sources such as radiators heat registers stoves and other Dvd cab rS products including amplifiers that produce heat 150d Sbuuugig jaueg Ian pue U014 VS0Z L VOH SJOjeoIpu snjelg 1 MOd L n D UO9IIMS JOMOd IEN kapuas eun ov O O O S v e L O O DI O DI peolano Waung J MOd s91f1 duy samog 124417 qQ31H
15. td Independent power supplies for each channel 1 6 kVA power transformer 100 000 uF filter capacitance in the HCA 1205A 1 KVA power transformer 68 000 uF filter capacitance in the HCA 855A Modular circuit board layout Massive toroid power transformer Multiple polystyrene film bypass capacitors in power supply Can be powered with external DC source Cascode Class A input stages with matched J FET pairs Hand picked complementary transistors in high voltage driver stage 15 ampere 50 MHz output transistors Output transistors direct coupled to speakers without LRC networks DC servo direct coupled audio circuits with 0 8 Hz rolloff High bias Class A AB operation Gold plated metal structure RCA input jacks Multiple protection circuits temperature sensors and silver cadmium relay protection Glass epoxy circuit boards double sided for precision Custom designed audiophile grade AC power cord THX The Parasound HCA 1205A is manufactured under license from Lucasfilm Ltd t Lucasfilm and THX are trademarks of Lucasfilm Ltd 2 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of dangerous voltage inside the product that may constitute a risk of electric shock d The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the liter
16. terchannel Crosstalk gt 80 dB at 1 kHz 60 dB at 20 kHz Input Impedance 33 kQ Input Sensitivity 1 V for 28 28 V 1 2 V for full output S N Ratio 115 dB full power IHF A weighted Damping Factor 800 at 20 Hz Dimensions 17 wide x 5 1 4 high x 16 deep 6 high with feet Power Requirements 110 Vac 120 Vac 750 Watts Net Weight 41 Ib 11 P PARASOUND Parasound Products Inc 950 Battery Street San Francisco CA 94111 415 397 7100 FAX 415 397 0144 1999 Parasound Products Inc
17. y Save all the packing material in case you need to ship the amplifier for repair Before you proceed find the serial number located on the rear panel of your amplifier and record it here for reference Serial Date of Purchase Installing and Rack Mounting Your Amplifier Place your amplifier away from heat sources such as air ducts and radiators Always mount the amplifier horizontally and make sure that your cabinet or shelf can support its weight Itis best to provide a separate shelf for your amplifier rather that stacking it directly above or below other components With the use ofthe optional Parasound RMK 3 both the HCA 1205A and HCA 855A occupy three rack spaces 5 1 4 in a standard 19 inch equipment rack Be sure to use the heavy duty mounting bolts with nylon shoulder washers on both sides of the faceplate to avoid scratching the amplifier s front panel and to help prevent ground loops This mounting hardware is included with the RMK 3 When rack mounting equipment have someone help support the unit while you bolt the component to the rack rails Ventilation Requirements for Your Amplifier To insure safe and reliable operation it is very important that the amplifier has plenty of ventilation to prevent overheating and automatic shut down from its thermal protection circuitry Please observe the following ventilation guidelines when installing your amplifier in a cabinet or other enclosed area 1 If you are not using a f

Download Pdf Manuals