Home
Lucent Technologies P333T Switch User Manual
Contents
1. Cajun P333T Unpack Quick Start Guide Run Web base Manager optional Lucent Technologies Bell Labs Innovations Unpack Check the package contents for the following If any items are missing or damaged contact your supplier Equipment e One Cajun P330 Layer 2 Workgroup Switch e One AC power cable e One RJ 45 to DB 9 serial adapter cable e Four rubber feet e Four screws with washers for rack mounting Ethernet connection cables are not supplied Documentation e Cajun P333T Quick Start Guide this document e Cajun P330 Release Notes e Cajun P330 Documentation and Utilities CD see detail below e Lucent Technologies Warranty and License Agreement Cajun P330 Documentation and Utilities CD The CD contains the latest User s Guides for the Cajun P330 stackable switches and files for use with the Embedded Web Manager User s Guides You can view and print these Guides using Adobe Acrobat Reader e Cajun P332MF e Cajun P333T e Cajun P334T e Cajun P333R e Cajun P330 Device Manager Auxiliary Files for use with the Embedded Web Manager Please refer to the documentation for information on how to use these files e Java plug in e Help files Adobe Acrobat Reader This application allows you to view and print the User s Guides on this CD Rack mount optional WARNING Disconnect all cables from the unit before proceeding with the rack installation 1 Snap open
2. Usar s Guide for details on how to install the plug in ona local web servar ia Document Done If the network manager has configured the system the plug in should be installed auto matically If the plug in is not installed automatically there are three ways to install the plug in manually Either install the plug in from the CD as follows Close all unnecessary applications on your PC 1 2 Insert the Cajun P330 Documentation and Utilities CD in the CD drive 3 Click Start on the Task bar 4 Select Run 5 Type x emweb aux files plugin_ 1 2 2 exe where x is the CD drive letter 6 Follow the on screen instructions Or install the plug in from the Lucent site by clicking on the link on the welcome page Or if the network manager has placed the files on the local site install the plug in from there by clicking the link on the welcome page If you have the Java plug in already installed or once you have successfully installed the plug in as described above the Web based manager opens in your browser A m O Oo WBE w OS li ti rs z jeuce E Device Zoom 148 49 32 40 fat gt Module 2 fZ noses EZ metue Module 8 Documentation and Online Help Refer to the Cajun P330 Documentation and Utilities CD for full instructions Notes Contact Information Lucent Technol
3. e input terminal block on the rear of the unit The terminals are marked and the IEC 5019a Ground symbol The size of the three screws in the terminal block is M3 5 The pitch between each screw is 9 5mm 2 Attach the appropriate lugs at the wire end of the power supply cord 3 Wire the DC power supply to the terminal block The unit powers up and performs a self test procedure The LEDs flash at regular intervals after the self test procedure is completed successfully WARNING The proper wiring sequence is ground to ground positive to positive line to L negative to negative neutral to N Always connect the ground wire first and disconnect it last Connect the cables Connect PCs servers routers workstations and hubs 1 Connect the Ethernet connection cable not supplied to a 10 100 Mbps port on the front panel of the Cajun P330 You should use standard RJ 45 connections You must use CAT 5 cable for 100 Mbps operation 2 Connect the other end of the cable to the Ethernet port of the PC server router worksta tion switch or hub Use a cross cable when connecting the Cajun P330 to a switch or hub 3 Check that the appropriate link LNK LEDs light up Connect the console cable 1 Configure the serial port settings of the PC or terminal as follows Baud Rate 9600 Parity no Data bits 8 Stop bits 1 Flow control no 2 Connect the supplied
4. ogies Inc Enterprise InterNetworking Systems Toll Free 1 888 ETHERNET Toll Free 800 CAJUNINF url http Awww lucent com ins Your feedback is important to us If you have any comments about our documentation please contact us by e mail at cajun info lucent com Cajun is a trademark of Lucent Technologies Inc All other trademarks registered trademarks service names product and or brand names are the sole property of their respective owners Copyright 2000 Lucent Technologies All rights reserved Catalog No 223555 Rev A July 2000
5. our browser Enter the URL of the switch in the form http aaa bbb ccc ddd aaa bbb ccc ddd is the IP address of the switch You are prompted to log into the switch The user name is root The default password for read write access is root The Web management passwords are the same as those of the CLI If you change the passwords in the CLI then use those passwords for Web management as well The welcome page is displayed Management Netscape E Boc S Lucent feces O Welcome to the Cajun P330 Device Manager 34 149 49 42 40 Cajun P330 Lucent Device Management Netscape If you do not have the Java plug in installed the following message appears a i n nip aaa 22a Z EP Whats Fetes BS E f O Eak 000 peod Home Seach Netscape Pmt Secub a Welcome to the Cajun P330 Device Manager This application requires tha Sun Microsystems Java Plug In version 1 2 2 to be installed in your browser IFitis not already installed an automate installation procedure will be initiated by your browser which will shortly request your confirmation tp install this plug in If this does not occur within few seconds you may also Rotriove itfrom wwin_luceninetworks com Alter download is complete run the executable you have downloaded to complete the plug in installation Install it from the Documentation GD provided with the P380 Device Rafer to the
6. special RJ 45 connector to the port marked Console on the front panel of the Cajun P330 3 Connect the other end of the cable to a terminal or PC with terminal emulation software installed Cajun P333T LEDs F RNE _ pens 00000000 0000000000060 aor 00000000 o00000000000 ba lt _ e _ gt O LNK COL Q Q FDX FC Hspd _ Left Right amp a A as aoe Reset Switches FIV switch Function LEDs FIV Force Initial Version see Cajun P330 Hspd Shows speed of port 10 Mbps or User s Guide 100 1000 Mbps LNK When ON link is OK LAG When ON the port is included in a COL When ON indicates a collision on Link Aggregation Group LAG the port in HDX mode ROUT Shows switch s mode of operation Tx Rx Shows traffic activity for SYS Shows whether this module is the transmitted and received packets Cajun P330 Stack Master agent FDX Shows Full Half Duplex mode OPR Shows CPU boot status FC When ON Flow Control is enabled for PWR Shows when power is on a port in FDX mode Basic configuration To connect a PC terminal or VT 100 terminal to the Cajun P330 1 If you are using a PC initiate a VT 100 terminal emulation session using an application such as Windows HyperTerminal Press Enter gt The Welcome to Cajun P330 menu is displayed Type the User name root when prompted and press En
7. ter Type the User Level password root when prompted and press Enter The Cajun _P330 N super prompt appears N is the number of the switch in the stack Assigning the Stack IP Address Commands are shown as follows set interface inband parameters which you need to enter are shown in lt gt as follows lt vlan gt Type set interface inband lt vlan gt lt ip address gt lt netmask gt replacing lt vlan gt lt ip_address gt and lt netmask gt with the VLAN IP address and net mask of the stack and press Enter Press Enter to save the VLAN IP address and net mask Type reset and press Enter to reset the stack at the Cajun_P330 N prompt After the Reset perform login to Privileged level again as described in step 1 The Cajun _P330 N super prompt appears Type set ip route lt dest gt lt gateway gt replacing lt dest gt and lt gateway gt with the destination and gateway IP addresses and press Enter Press Enter to save the destination and gateway IP addresses Setting the Parameters If you wish to change the default parameters shown and configure the mandatory parameters we recommend that you use the Command Line Interface CLI For further information please refer to Chapter 6 of the Cajun P330 User s Guide Default Switch Parameters Configuration Parameter Cajun P330 IP Address Default Setting 149 49 32 134 BootP Mode Never Default Gate
8. the hinged ends of the unit s front panel to reveal the screw holes Closed hinged end Screw 4 holes Position the unit in the rack 3 Secure the unit to the rack taking care not to overtighten the screws Snap closed the hinged ends of the front panel You can now safely connect the cables to the unit Power up Cajun P330 AC Version 1 Insert the power cord into the power connector BUPS or Power Supply on the rear of the unit BUPS connector AC connector ID T W 2 Insert the other end of the power cord into the electricity supply or the BUPS connector The unit powers up and performs a self test procedure The LEDs flash at regular intervals after the self test procedure is completed successfully Cajun P330 DC Version WARNING Before performing any of the following procedures ensure that DC power is OFF CAUTION This product is intended for installation in restricted access areas and is approved for use with 18 AWG copper conductors only The installation must comply with all applicable codes DC terminal block 1 Connect the power cable to the switch at th
9. way 0 0 0 0 Management PC SLIP IP Address 192 168 10 2 VLAN Management ID 1 Spanning Tree Enabled TFTP Mode Limited TFTP Server 0 0 0 0 TFTP File Name viisa Default Port Parameters Configuration Parameter Port Speed and Duplex Mode Default Setting e 10 100 TX ports Auto negotiation e 100Base FX ports 100 Mbps full duplex e 1000Base X ports 1000 Mbps full duplex Flow Control e 10 100 and 100 Mbps Disabled e 1000 Mbps Disabled no pause Backpressure e 10 100 Enabled when in half duplex mode e 100Base FX amp 1000 Mbps Not applicable Auto negotiation e 10 100 TX ports Enabled e 100Base FX ports Not applicable e 1000Base X ports Enabled Administration State Enabled Port VLAN ID 1 Tagging Mode Clear Port Priority Regular Run the Web Based Manager optional To configure the Cajun P330 you can use the P330 Web based Manager in addition to using the CLI System Requirements Minimum hardware and Operating System requirements are Windows 95 or NT 4 0 or higher Pentium 200 Mhz based computer with 64 Mb of RAM Pentium II recommended Minimum screen resolution of 1024 x 768 pixels Microsoft Internet Explorer 4 or higher or Netscape Navigator 4 x or higher Sun Microsystems Java plug in version 1 2 2 supplied Running the Embedded Manager Assign an IP address to the P330 before starting this procedure Open y
Download Pdf Manuals
Related Search
Related Contents
Model 1200/1201 Synchronous Modem Eliminator User Manual Télécharger - Toyota Gatineau SCOTT® E-Z AIRLINE Copyright © All rights reserved.
Failed to retrieve file