Home

Kenmore 153.33429 Water Heater User Manual

image

Contents

1. 7 0 7 Installation 113511711071010 8 8 16 Removing the Old Water Heatet sssssssssssssssssssssessssnensessssneesssnecuccscenensnssnssescacssccavessssscsassuasunsnusssasaasassnncesssessancancansnssaneanenss 8 Facts to Consider About the Location sesssssssssssensereeeesssasaeseortesrerrortonissrenneseontnnrnnntndoveosesrerstesaseostenereveanedaedaereeetrenseuseseentrrttsnee 9 10 10 Water 171 H Temperature Pressure Relief 7 77 12 Filling the 7 3 isccisosicsecsssusiusncs sata aosentauninn deeuinnashcsnssssosaiagsasuan onaxsinstunsoniunani dia bes Ganvaneaacnivopinndauiiad tyeseyaboreiaertisatbvanesseadyseensenanicdpet 13 14 Gas Piping vsssisesissccscassnssovssesisensenncsnssncseastnennnanasounaniabboudsuasdsvesdueisipsasascusravesussadsssssssosnsbabiasanatesnensessas cssoustonanseaserecexcazcesoune 14 15 Installation Checklist 0 0 4 16 Operating Instructions Temperature Regulation 2 Service and Adjustment set oe ela ements 20 21 Tank 7 77 7 2 7 7 20 Venting System Inspection sssssssrsssecssssssssssesnsnessssssecserneseaeesersssssesnencnssessssssececsconsnssnaaccseseanesessssassensesensnseneasasenssoreresiaataees 20 Burner Inspection 7 20 Burner 20 0 21 Temperature Pressure Relief Valve Operation ssssssessseesssserssssesscseesssssssessccscncenenssanssssusanseseavesssseceecas
2. At least once a m a visual nee should be made of the main burner and pilot burner The drawing is for your reference You should check for sooting which is not normal and will impair proper combustion A WARNING Soot build up indicates a problem that requires correction before further use Turn OFF gas to water heater and leave OFF until repairs are made because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Burner Cleaning In the event your burner needs cleaning use the following instructions If inspection of the burner shows that cleaning is required turn the gas control knob clockwise C N to the OFF position depressing slightly NOTE The knob cannot be turned from PILOT to OFF unless knob is depressed slightly DO NOT FORCE Loose deposits on or around the burner can be removed by care fully using the hose of a vacuum cleaner inserted through the access door of the water heater If the burner needs to be removed for additional cleaning call the Sears Service Center to remove and clean the burner and correct the problem that required the burner to be cleaned Service and Adjustment cont d Draining The water heater should be drained if being shut down during freezing temperatures Also pees draining and cleaning of sediment from the tank may be necessary e Turn the gas cont
3. 00154 soorsss_ Aa x 1 x thick 9001584 9001584 9001584 9001584 8 Thermocouple 42 33900 9000278 teases Oo eae Drill Size 37 42 40 40 12 Burner 9002411 9002411 9002411 9002411 13 Manifold Cover 900038 _ 1 14 Outer Door 9000351 9000351 9000351 F145 1280 F145 1280 9000272 90075 These parts are also available at most Sears retail stores Also available at most hardware stores Replaced only on return of damaged plate Not Illustrated Now that you have purchased this water heater should a need ever exist for repair parts or service simply contact any SEARS Service Center or call 1 800 4 MY HOME 1 800 469 4663 Be sure to provide pertinent facts when you call or visit All parts listed may be ordered from any SEARS Service Center most SEARS stores and by calling 1 800 366 PART 1 800 366 7247 If the parts you need are not stocked locally your order will be electronically transmitted to a SEARS Repair Parts Distribution Center for handling The model number of your Gas Water Heater will be found on the model rating plate located near the gas control valve WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER PART DESCRIPTION PART NUMBER NAME OF ITEM THIS IS A REPAIR PARTS LIST NOT A PACKING LIST 27 Warranty About Your Warranty THE PRICE OF YOUR WATER HEATER DOES NOT INCLUDE
4. ROLL OF LEAD FREE SOFT SOLDER ROLL OF EMERY CLOTH PROPANE TORCH SOLDER FLUX TUBING CUTTER Installation Instructions Removing the Old Water Heater 1 Turn OFF the gas supply to the water heater 5 Disconnect the vent pipe from the draft hood where they connect to the water heater In most installations AWARNING the vent pipe can be lifted off after any screw or other attached devices are removed Dispose of the draft If the main gas line shutoff serving all gas appliances is used also shut OFF the gas at each appliance Leave all hood The new water heater has the draft hood which must be used for proper operation gas appliances shut OFF until the water heater installa tion is complete a If you have copper piping to the water heater the two copper water pipes can be cut with a hacksaw approximately 4 away from where they connect to the water heater This will avoid cutting off the pipes too short Additional cuts can be made later if necessary Disconnect the temperature pressure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely discon nected and ready to be removed Turn OFF the water to the water heater Some installations require that the water be turned off to the entire house If you have galvanized pipe to the water heater loosen
5. Vent pipes must be secured at each joint with sheet metal screws CHIMNEY MIN 4 INCH RISE PER LINEAR FOOT VENT PIPE INSTALLATION There must be a minimum of 6 clearance between single wall vent pipe and any combustible material Fill and seal any clear ance between single wall vent pipe and combustible material with mortar mix cement or other noncombustible substance For other than single wall follow vent pipe manufacturer s clear ance specifications To insure a tight fit of the vent pipe in a brick chimney seal around the vent pipe with mortar mix cement AWARNING Failure to have required clearances between vent piping and combustible material will result in a fire hazard A WARNING Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation A WARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive Gas Piping Make sure the gas supplied is the same type listed on the model rating plate The inlet gas pressure must not exceed 14 inches water column 4 pound per square inch 3 5kPa The minimum inlet gas pr
6. 50psi Tank Capacity Needed Highest recorded inlet water pressure in a 24 hour period or regulated water pressure NOTE Expansion tanks are pre charged with a 40 psi air charge If he inlet water pressure is ue than 40 psi the expansion tank s air pressure must be adjusted to match that pressure but must not be higher than 80 psi Troubleshooting Guide cont d WATER HEATER COLD e COLD WATER INLET COLD PRESSURE GAUGE INLET CO SHUTOFF RECOMMENDED INSTALLATION VERTICAL MOUNTING WATER HEATER FLOOR CEILING COLD WATER JOIST ETC INLET FITTING PRESSURE REDUCING INLET COLD AL PRESSURE GAUGE ALTERNATE RECOMMENDED INSTALLATION HORIZONTAL MOUNTING STRANGE SOUNDS Possible noises due to expansion and contraction of some metal pare during periods of heat up and cool down do not represent armful or dangerous conditions Condensation causes sizzling and popping with the burner area during heating and cooling periods and should be considered normal See Condensation section 23 Operational Conditions SMELLY WATER In each glasslined water heater there is installed at least one anode rod see parts section for corrosion protection of the tank Certain water conditions will cause a reaction between this rod and the water The most common complaint associated with the anode rod is one of a rotten egg smell This odor is derived from hydrogen sul
7. A FREE CHECKUP SERVICE CALL On Water Heater Installations Arranged By Sears Sears warrants the installation ON INSTALLATIONS NOT MADE BY SEARS AUTHORIZED CONTRACTORS 1 Your Sears warranty applies to the product only 2 Sears does not warrant the installation 3 A charge will be made on service calls due to poor or incomplete installation These include a Adjusting thermostat b Lighting pilot c Leaks in pipes or fittings d Improper venting e Condensation This manual is in non technical language It may help you avoid the cost of a needless service call Many service calis really arent needed Such as when 1 The gas is turned OFF 2 The pilot is out 3 A gas or water leak is due to loose pipe or connections LIMITED WARRANTY ON TANKS THAT LEAK Through five 5 years from the date of purchase if a leak occurs in the tank Sears will furnish free of charge a new current mode water heater of closest available capacity and quality If purchaser does not qualify for free installation as provided in the One Year Limited Labor Warranty below there will be a charge for installation If the replacement water heater of closest available capacity and quality does not meet current applicable government standards there will be a charge for the difference in price between the replacement which does not meet government standards and one which does meet govern ment standards If the water heater is subjected to co
8. Gas Water Heater installation Kit smn WATER HEATER STAND 24 x24 x18 FOR USE WITH WATER HEATERS INSTALLED IN RESIDENTIAL GARAGES HAVING A DIAMETER 24 OR LESS AND A RATED CAPACITY 75 GALLONS OR LESS FLEXIBLE WATER HEATER GAS CON NECTOR WITH FITTINGS THROUGH LOCAL SEARS STORE OR E SERVICE CENTERS WATER HEATER INSTAL DRAIN PANS AVAILABLE IN 20 DIAME LATION KIT WITH FLEXI TER FOR WATER HEATERS HAVING A BLE CONNECTORS FOR WATER HEATER HEAT DIAMETER 18 OR LESS AND AVAIL 3 4 OR 1 2 THREADED TRAPS HELP REDUCE HEAT ABLE IN 28 DIAMETER FOR WATER OR COPPER PLUMBING VENT PIPE LOSS DUE TO THERMAL HEATERS HAVING A DIAMETER 26 OR SYPHONING LESS Basic Tools You may or may not need all of these tools depending on your type of installation These tools can be purchased at your local Sears store Pipe Wrenches 2 14 Screwdriver Tin Snips 6 Foot Tape of Folding Rule Garden Hose Drill e Pipe dope or Teflon Tape GARDENHOSE FOOT TAPE PIPE SLOT HEAD SCREWDRIVER PHILLIPS SCREWDRIVER CD TIN SNIPS 2 ROLL OF TEFLON TAPE USE ONLY ON WATER CONNECTIONS PIPE DOPE SQUEEZE TUBE USE FOR WATER AND GAS CONNECTIONS ADDITIONAL TOOLS NEEDED WHEN SWEAT SOLDERING Tubing Cutters or Hacksaw Propane Torch Soft Solder Solder Flux Emery Cloth Wire Brushes HACKSAW 3 4 WIRE BRUSH Cane 1 2 WIRE BRUSH
9. If the water was extremely hot and is now cold the high limit safety temperature shut off may have put out the burner and pilot If the high temperature shut off activates the gas eaa perk must be replaced Contact the Sears Service Center The gas contro knob must be turned to the ON position The temperature adjustment dial may be set too low See the Temperature Regulation section The gas company can check the gas input to see if it is correct An underfired water heater will not heat water as quickly Look for leaking or open hot water faucets Make sure all are closed The cold water inlet temperature may be colder during the winter months It will take longer to heat the water and seem like less hot water Ifyou cannot find what is wrong call the Sears Service Center 24 WATER IS TOO HOT The temperature adjustment dial may be set too high See the Temperature Adjustment section NOTE A period of time is necessary after an adjustment has been made for the water temperature to reach the new temperature setting If lower temperature settings will not lower the water tempera ture call the Sears Service Center AWARNING HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some peo ple are more likely to be per
10. A WARNING If this water heater will be used in beauty shops barber shops cleaning establishments or self service laundries with dry cleaning equipment it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas Refer to the Facts to Consider About the Location section of this manual and also the latest edition of the National Fuel Gas Code ANSI Z223 also referred to as NFPA 54 for specifics provided concerning air required Installation Instructions cont d Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 0 cubic feet per 1 000 Btu per hour of the aggregate input rating of all appliances installed in that space Rooms communicatin directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space In unconfined spaces in buildings infiltration may be adequate to provide air for combustion ventilation and dilution of flue gases However in buildings of tight construction for example weather stripping heavily insulated caulked vapor barrier etc additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Located in Confined Spaces b Combustion Air and Ventilation for Appliances Located in Confine
11. National Standards for Gas Water Heaters The installa tion must conform with this manual Local Codes and with the latest edition of the National Fuel Gas Code ANSI Z223 1 This publication is available from your local government or public library gas company or by writing NFPA Batterymarch Park Quincy MA 02269 Read the Safety Precautions section pages 2 through 4 of this manual first and then the entire manual carefully If you don t follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation opera tion and maintenance of the gas fired water heater It also contains warnings through out the manual that you must read and be aware of All warnings and all instructions are essential to the proper operation of the water heater and your safety Since we cannot put everything on the first few pages READ THE ENTIRE MANUAL BEFORE A NG TO INSTALL OR OPERATE THE WATER HEATER The installation must conform with the instructions in this manual gas company rules and Local Codes or in the absence Ai Local Codes with the latest edition of the National Fuel Gas code ANSI Z223 1 also referred to as NFPA 54 This publication is available from your local government or public library or gas company or by writing NFPA Batterymarch Park Quincy MA 02269 If after reading this manual you have any
12. al equipment in the enclosure See Figure 3 2 When communicating with the outdoors through vertical ducts each opening shall have a minimum free area of 1 sar inch per 4 000 BTU per hour of total input rating of all equipment in the enclosure See Figure 4 CHIMNEY OR GAS VENT VENTRATION LOUVERS each end of amc WATER HEATER FURNACE INLET AIR DUCT 1 above Noor 3 When communicating with the outdoors through horizontal ducts each opening shall have a minimum free area of 1 square inch per 2 000 BTU per hour of total input rating of al equipment in the enclosure See Figure 5 ee OF GAS VENT OUTLET AIR DUCT H 5 A MI AIA DUCT ee 4 When ducts are used they shall be of the same cross sectional area as the free area of the openings to which they connect The minimum short side dimension of rectangular air ducts shall not be less than 3 See Figure 5 5 Louvers and Grilles In calculating free area consideration shall be given to the blocking effect of louvers grilles or screens protecting openings Screens used shall not be smaller than 4 mesh If the free area through a design of louver or grille is known it should be used in calculating the size open ing required to provide the free area specified If the design and free area is not known it may be assumed that wood lou vers will be 20 25 percent
13. free area and metal louvers and grilles will have 60 75 percent free area Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation 6 Special Conditions Created by Mechanical Exhauscing or Fireplaces Operation of exhaust fans ventilation systems clothes dryers or fireplaces may create conditions ane special attention to avoid unsatisfactory operation of installe gas utilization equipment Installation Instructions cont d Water Piping HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some peo ple are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physical lyimentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions in addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow man ufacturers instruct
14. questions or do not understand any portion of the instructions call the Sears Service Center Carefully plan the place where you are going to put the water heater Correct combustion vent action and vent pipe instal lation are very important in preventing death from possible carbon monoxide poisoning and fires Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual For California installation this water heater must be braced anchored or strapped to avoid falling or moving during an earthquake See instructions for correct installation proce dures Instructions may be obtained from your local dealer wholesaler public utilities or California Office of the State Architect 400 P Street Sacramento CA 95814 DIMENSIONS IN INCHES RECOVERY RATE MINIMUM GALS PER HOUR VENT 90 F RISE PIPE MODEL NUMBER HEIGHT TO JACKET TOP 153 334490 40 153 334590 50 153 334290 4 153 334390 50 2 Materials and Basic Tools Needed Materials Needed To simplify the installation Sears has available the installation parts shown below You may or may not need all of these materi als depending on your type of installation Sal 8 Water Heater installation Kit EXPANSION TANKS FOR THERMAL EXPANSION CONDI TIONS AVAILABLE IN 2 GALLON AND 5 GALLON CAPACITY 23 r Es Pai a an i ee a 1 i io Sia joi 0 lio jan jan
15. relief valve DO NOT put insulation over any part of the top of the gas water heater DO NOT put insulation over the gas control valve or gas control valve burner cover or any access areas to the burner DO NOT let insulation around the gas water heater to get within 8 inches of the floor air must get to the burner DO NOT cover or remove operating instructions and safety related warning labels and materials affixed to the water heater Failure to heed this will result in the possibility of a fire or explosion ACAUTION WATER HEATERS EVENTUALLY LEAK Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak the flow of water will not cause damage to the structure When such locations cannot be avoided a suitable drain pan should be installed under the water heater Drain pans are avail able at your local Sears store Such a drain pan must be not greater than 1 4 inches deep have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain The pan must not restrict combustion air flow Under no circumstances is the manufacturer or Sears to be held liable for any water damage in connection with this water heater Table of Contents 2 4 TablesOF Contents merria enana a E adele ate 5 Customer 0 6 0 na oa E 6 Materials and Basic Tools 1166060 7 Materials
16. the two galvanized pipes with a pipe wrench at the union in each line Also disconnect the piping remain ing to the water heater These pieces should be saved since they may be need ed when reconnecting the new water heater Disconnect the temperature pres sure relief valve drain line When the water heater is drained disconnect the hose from the drain valve Close the drain valve The water heater is now completely disconnected and ready to be removed 3 Check again to make sure the gas supply is OFF to the water heater Then dis connect the gas supply connection from the gas control valve Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors Open the water heater drain valve Open a nearby hot water faucet which will relieve pressure in the water heater and speed draining A WARNING The water passing out of the drain valve may be extremely hot To avoid being scalded make sure all connections are tight and that the water flow is directed away from any person ACAUTION Mineral buildup or sediment may have accumulated in the old water heater This causes the water heater to be much heavier than normal and this residue if spilled out could cause staining Installation Instructions cont d Facts to Consider About the Location You should carefully choose an indoor location for the new water heater because the placement is a very important consid er
17. vapor which can condense on the cooler surfaces of the tank Droplets form and drip into the fire or run on the floor This is common at the time of startup after installation and when incoming water is cold Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary correc tive steps taken Leakage from other appliances water lines or ground seepage should also be checked NOTE To check where threaded portion enters tank insert cotton swab between jacket opening and fitting If cotton is wet follow Draining instructions in the Service and Adjustment section and then remove fitting Put pipe dope or teflon tape on the threads and replace Then follow Filling the Water Heater instructions in the Installation Instructions section Parts Order List KENMORE ENERGY EFFICIENT 5 GAS WATER HEATERS MODEL NUMBERS 153 334290 40 Gal Short 153 334390 30 Gal 153 334490 40 Gal 153 334590 50 Gal 26 Parts Order List cont d KENMORE ENERGY EFFICIENT 5 GAS WATER HEATERS MODEL NUMBERS 153 334290 40 Gal Short 153 334390 30 Gal 153 334490 40 Gal 153 334590 50 Gal MODEL NUMBERS KEY 153 334290 153 334390 153 334490 0 NO PART DESCRIPTION 1 Temperature Pressure Relief Valve 9000071 9000071 1 Cia x
18. water outlet is marked hot Put two or three turns of teflon tape around the threaded end of the threaded to sweat coupling and around both ends of the threaded nipple Using flexible connec tors connect the hot water pipe to the hot water outlet on the water heater Look at the top cover of the water heater The cold water inlet is cold Put two or three turns of teflon tape around the threaded end of the threaded to sweat coupling and around both ends of the threaded nipple Using flexi ble connectors connect the cold water pipe to the cold water inlet of the water heater NOTE This water heater is super insulated to minimize heat loss from the tank Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater INSTALLATION COMPLETED USING SEARS INSTALLATION KIT SHUTOFF FLEXIBLE WATER VALVE CONNECTORS lt TO HOUSE WATER LINE THREADED TO SWEAT COUPLING THREADED TO 3 4 THREADED SWEAT COUPLING 3 4 THREADED NIPPLE NIPPLE TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE Do not cap or plug 6 AIR GAP FLOOR DRAIN Installation Instructions cont d Temperature Pressure Relief Valve A WARNING At the time of manufacture this water heater was provided with a combination temperature pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of li
19. 3 300 feet or a high altitude model is installed above 5 500 feet the input rating must be reduced at the rate of 4 percent for each 1 000 feet above sea level Contact your local Sears Service Center or gas utility for further information A WARNING The appliance and its gas connection must be leak tested before placing the appliance in operation Installation Instructions cont d A WARNING The appliance and its individual shutoff vaive must be discon nected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of 4 pound per square inch 3 5kPa The appliance must be isolated from the gas supply piping sys tem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test sures equal or less than 4 pound per square inch 3 5kPa AWARNING Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum Propane L P gases SEDIMENT TRAP A sediment trap shall be installed as close to the inlet of the water heater as practical at the time of water heater installation The sediment trap shall be either a tee fitting with a capped nip ple in the bottom outlet or other device recognized as an effec tive sediment trap If a tee fitting is used it shall be installed in conformance with one of the methods of installation shown below Connecting the gas piping to
20. 366 7278 The Service Side of Sears The model number of your water heater is found on the model rating plate on the front of the water heater 11 98 Sears Roebuck and Co Hoffman Estates IL 60179 U S A 00029 15380 0
21. AM AGE Refer to this manual for assistance or consult the local Sears Service Center or gas utility for further information A WARNING Flammable vapors may be drawn by air currents from other areas of the structure to this appliance A WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Precautions Improper installation adjustment alteration service or maintenance can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Refer to this manu al for assistance or consult your local Sears Service Center for further information A WARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY This water heater is equipped for one type gas only Check the model rating plate near the gas control valve for the correct gas DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE Failure to use the correct gas can cause problems which can result in DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE If you have any questions or doubts consult your gas supplier or local utility A WARNING INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ UIDS VAPORS ARE LIKELY BE PRESENT OR STORED GARAGES STORAGE AND UTILITY AREAS ETC Flammable liquids such as gasoline solvents propane LP or butane etc all o
22. AREA To insure sufficient venti lation and combustion air supply proper clearances from the water heater must be maintained See Facts to Consider About the Location section Combustible materials such as dothing cleaning materials or flammable liquids etc must not be placed against or adjacent to the water heater which can cause a fire Service Before calling for repair service read the Start Up Conditions and Operational Conditions found in the Troubleshooting Guide of this manual If a condition persists or you are uncertain about the operation of the water heater let a qualified person check it out Contact SEARS Repair Services at 1 800 4 MY HOME 1 800 469 4663 Troubleshooting Guide Start Up Conditions CONDENSATION Whenever the water heater is filled with cold water a certain amount of condensation will form while the burner is on A water heater may appear to be leaking when in fact the water is condensation This usually happens when When a new water heater is filled with cold water for the first time When gas burns and water vapor is produced in water heaters particularly high efficiency where flue tem peratures are lower When you use large amounts of hot water in a short time and the refill water is very cold Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surface
23. ATURE PRESSURE RELIEF VALVE DISCHARGE PIPE Do not cap or plug TEE gt ow le DRAIN VALVE DRIP LEG Sediment trap CAP gt O 6 AIR GAP FLOOR DRAIN MODEL RATING PLATE Operating Instructions Lighting BEFORE LIGHTING PROPANE L P GAS WATER HEATERS Propane L P gas is heavier than air Should there be a leak in the system the gas will settle near the ground Basements crawl spaces skirted areas under mobile homes even when ventilated closets and areas below ground level will serve as pockets for the accumulation of this gas Before attempting to light or relight the water heater s pilot or turning on a nearby electrical light switch be absolutely sure there is no accumulated gas in the area Search for odor of gas by sniffing at ground level in the vicinity of the appliance if odor is detected follow steps indicated at For Your Safety on the cover page of this manual then leave the premises Lighting and operating instructions are located on front of the water heater above or to one side of the gas control valve A WARNING AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER FOR YOUR SAFETY IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your ga
24. BLE LIQUIDS VAPORS ARE LIKELY TO BE PRESENT OR STORED GARAGES STORAGE AND UTILITY AREAS ETC Flammable liquids such as gasoline solvents propane LP or butane etc all of which emit flammable vapors may be improperly stored or used in such areas The gas water heater pilot light or main burner can ignite such vapors The resulting flashback and fire can cause death or serious burns to anyone in the area as well as property damage if installation in such areas is your only option then the installa tion must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor at least 18 inches While this may reduce the chances of flammable vapors from a floor spill being ignited gasoline and other flammable substances should never be stored or used in the same room or area con taining a gas water heater or other open flame or spark produc ing appliance NOTE Flammable vapors may be drawn by air currents from other areas of the structure to the appliance A WARNING Propeltants of aerosol sprays and volatile compounds clean ers chlorine based chemicals refrigerants etc in addition to being highly flammable in many cases will also change to cor rosive hydrochloric acid when exposed to the combustion products of the water heater The results can be hazardous and also cause product failure The location selection must provide sas ee clearances fo
25. Kenmore Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MOBILE HOMES Model No 153 334290 40 Gal Short 153 334390 30 Gal 153 334490 40 Gal 153 334590 50 Gal Caution Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product Save this Manual for Future Reference ENERGY EFFICIENT 5 GAS WATER HEATER Safety Instructions Care and Maintenance Installation Troubleshooting e Operation e Parts List For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER WARNING If the information in these instructions are not fol lowed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liq uids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance 2 por touch any electrical switch do not use any phone in your uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier A WARNING Improper installation adjustment alteration service or maintenance can cause DEATH SERIOUS BODILY INJURY OR PROPERTY D
26. airs Is the new temperature pressure relief valve properly installed and piped to an adequate drain See Temperature Pressure Relief Valve section Are the cold and hot water lines connected to the water heater correctly See Water Piping instructions in the Installation Instructions section Is the water heater completely filled with water See Filling instructions in the Installation Instructions section Will a water leak damage anything See the Facts to Consider About the Location section Is there proper clearance between the water heater and any thing that might catch fire See the Facts to Consider About the Location section Do you have adequate ventilation so that the water heater will operate properly See Combustion Air and Ventilation in the Facts to Consider About the Location section Is the draft hood vent piping properly secured See Venting instructions in the Installation Instructions section Is there proper clearance between the vent pipe and anything that might catch on fire See Venting instructions in the Installation Instructions section Is the vent pipe properly sloped and does the vent terminate outdoors See Venting instructions in the Installation Instructions section Do you need to call your gas company to check the gas pipe and its hookup VENT PIPE TO Oh SHUTOFF VALVE TEMPER
27. ation for the safety of the occupants in de building and for the most economical use of the appliance This water heater is not for use in mobile homes or outdoor installation Whether replacing an old water heater or putting the water heater in a new location the following critical points must be observed The location selected should be indoors as close 35 practical to the gas vent or chimney to which the water heater vent is going to be connected and as centralized with the water pip ing system as possible The water heater as all water heaters will leak Do not install without adequate drainage provisions where water flow will cause damage A CAUTION WATER HEATERS EVENTUALLY LEAK Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak the flow of water will not cause damage to the structure When such locations can not be avoided a suitable drain pan should be installed under the water heater Drain pans are available at your local Sears store Such a drain pan must be not greater than 11 4 inches deep have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain The pan must not restrict combustion air flow Under no circumstances is the manufacturer or Sears to be held liable for any water damage in connection with this water heater AWARNING INSTALLATIONS IN AREAS WHERE FLAMMA
28. ational Fuel Gas Code ANSI Z223 1 also referred to as NFPA 54 Check the ormi system for signs of obstruction or deteriora tion and replace if needed The combustion and ventilation air flow must not be obstructed A WARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation Place the draft hood legs in the receiving holes on the top of water heater The legs will snap in the holes to give a tight it Place the vent pipe over the draft hood With the vent pipe in position drill a small hole through both the vent pipe and draft hood Secure them together with a sheet metal screw DRAFTHOOD aat R 4 SCREW DRAFT HOOD VENT TO OUTDOORS OR D CHIMNEY b A WARNING The water heater with draft hood installed must be properly vented to a chimney which terminates outdoors Never oper ate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation explo sion or asphyxiation A WARNING The vent pipe from the water heater must be no less than the diameter of the draft hood outlet on the water heater and must slope upward to the chimney at least inch per linear foot Installation Instructions cont d Venting cont d All vent gases must be completely vented to the outdoors of the structure dwelling Install only the draft hood provided with the new water heater and no other draft hood
29. ct Some peo ple are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physical lyimentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow man ufacturers instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual A WARNING Never allow small children to use a hot water tap or to draw their own bath water Never leave a child or handicapped per son unattended in a bathtub or shower The thermostat of this water heater has been factory set at its lowest position to reduce the risk of scald injury It is adjustable and must be reset to the desired temperature setting The mark A HOT indicative of 0 120 F is the preferred sarang point Some states have a requirement for a lower set ting If you need hotter water follow directions for temperature adjustment but beware of the warnings in this secti
30. d Spaces Confined Space is a space whose volume is less than 50 cubic feet per 1 000 Btu per hour of the aggregate input rating of all appliances installed in that space a ALL AIR FROM INSIDE BUILDINGS See Page 9 Figure 1 and Figure 2 below The confined space shall be provided with two permanent openings communicating directly with an additional room s of sufficient volume so that the combined volume of all spaces meets the criteria for an unconfined space The total input of all gas utilization equipment installed in the com bined space shall be considered in making this determination Each opening shall have a minimum free area of one square inch per 1 000 BTU per hour of the total input rating of ali gas utilization equipment in the confined space but not less than 100 square inches One opening shall commence within 12 of the top and one commencing within 12 of the bot tom of the enclosure b ALL AIR FROM OUTDOORS see Figures 3 5 The confined space shall be provided Wt two permanent openings one commencing within 12 of the top and one commencing within 12 from the bottom of the enclosure The openings shall communicate directly or by ducts with the outdoors or spaces crawl or attic that freely communi cate with the outdoors CHIMNEY OA GAS VENT 1 When directly communicating with the outdoors each open ing shall have a minimum free area of 1 square inch per 4 000 BTU per hour of total input rating of
31. d com bustible or non combustible construction are at the sides and rear 4 at the front and 6 from the vent pipe Clearance from the top of the jacket is 18 on most mod els Note that a lesser dimension may be allowed on some models Refer to the label on the water heater adjacent to the gas control valve for all clearances A WARNING Do not use this appliance if any part of it has been under water Immediately call a Sears Service Technician to inspect the appliance and to replace the gas control or any part of the burner system which has been under water AWARNING HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possi bility of injury under these conditions we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used such as a dis hwasher or washing machine If hydrogen gas is present there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened There must be no smoking or open flame near the faucet at the time it is open A WARNING INSULATING JACKETS When installing an external water heater insulation jacket on a gas water heater DO NOT cover the temperature pressure
32. e liquids are placed against or next to the water heater A WARNING At the time of manufacture this water heater was provid ed with a combination temperature pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems and the latest edition of ANSI Z21 22 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI 221 22 by a nationally rec ognized testing laboratory that maintains periodic inspection of production of listed equipment or materials The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater 150 Ibs sq in and a discharge capacity not less than the water heater input rate as shown on the model rating plate Electric heaters watts divided by 1000 x 3415 equal BTU Hr rate Your local jurisdictional authority while mandating the use of a temperature pressure relief valve complying with ANSI Z21 22 and ASME may require a valve model different from the one furnished with the water heater Compliance wit
33. e than the outlet pipe size of the valve or have any reducing couplings or other restrictions Must not be plugged or blocked Must be of material listed for hot water distribution Must be installed so as to allow complete drainage of both the temperature pressure relief valve and the dis charge pipe Must terminate at an adequate drain Must not have any valve between the relief valve and tank Safety Precautions A gas water heater cannot operate properly without the correct amount of air for combustion Do not install in a confined area such a closet unless you provide air as shown in the Facts to Consider About the Location sec tion Never obstruct the flow of ventilation air If you have any doubts or questions at all call your gas company Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE A WARNING HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a tem perature which will satisfy clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically men tally handicapped If anyone using hot water in your home fits into o
34. erent from the one furnished with the water heater Compliance with such local requirements must be satisfied by the instalter or end user of the water heater with a locally prescribed temperature pressure relief valve installed in the designated opening in the water heater See manual heading Temperature Pressure Relief Valves for installation and mainte nance of relief valve discharge line and other safety precautions Installation Instructions cont d Filling the Water Heater 4640708 Never use this water heater unless it is completely filled with water To prevent damage to the tank the tank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater To fill the water heater with water Close the water heater drain valve by turning the handle to the right clockwise The drain valve is on the lower front of the water heater e Open the cold water supply valve to the water heater NOTE The cold water supply valve must be left open when the water heater is in use e To insure complete filling of the tank allow air to exit by opening the nearest hot water faucet Allow water to run until a constant flow is obtained This will let air out of the water heater and the piping Check all new water piping for leaks Repair as needed Venting A WARNING VENT DAMPERS Any vent damper whether it is operated thermally or ot
35. essure listed on the model rating plate is for the purpose of input adjustment AWARNING if the gas control valve is subjected to pressures exceeding 4 pound per square inch 3 5kPa the damage to the gas con trol valve could result in a fire or explosion from leaking gas AWARNING If the main gas line shutoff serving all gas appliances is used also turn OFF the gas at each appliance Leave all gas appli ances shut off until the water heater installation is complete A gas line of sufficient size must be run to the water heater Consult the latest edition of National Fuel Gas Code ANSI Z223 1 also referred to as NFPA54 and the gas company concern ing pipe size There must be A readily accessible manual shut off valve in the gas supply line serving the water heater and A drip leg sediment trap ahead of the gas control valve to hel Ip diet and foreign materials from entering the gas contro ve A flexible gas connector or a ground joint union between the shutoff valve and control valve to permit servicing of the unit Be sure to check all the gas piping for leaks before lighting the water heater Use a soapy water solution not a match or open flame Rinse off soapy solution and wipe dry Standard Models are for installation up to 3 300 feet above sea level High Altitude Models are for installation from 3 300 to 5 500 feet above sea level If a standard model is installed above
36. f which emit flammable vapors may be improperly stored or used in such areas The gas water heater pilot light or main burner can ignite such vapors The resulting flashback and fire can cause death or serious burns to anyone in the area as well as property damage If installation in such areas is your only option then the installation must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor at least 18 inches While this may reduce the chances of flammable vapors from a floor spill being ignited gasoline and other flammable substances should never be stored or used in the same room or area containing a gas water heater or other open flame or spark producing appliance NOTE Flammable vapors may be drawn by air currents from other areas of the structure to the appliance A WARNING if this water heater will be used in beauty shops barber shops cleaning establishments or self service laundries with dry cleaning equipment it is imperative that the water heater or water heaters be installed so that com bustion and ventilation air be taken from outside these areas Refer to the Facts to Consider About the Location section of this manual and also the latest edi tion of the National Fuel Gas Code ANSI Z223 1 also referred to as NFPA 54 for specifics provided concerning air required A WARNING A fire can start if combustible materials such as clothing cleaning materials or flammabl
37. fide gas dissolved in the water The smell is the result of four factors which must all be present for the odor to develop a a concentration of sulfate in the supply water b little or no dissolved oxygen in the water c a sulfate reducing bacteria within the water heater This harmless bacteria ts non toxic to humans d an excess of active hydrogen in the tank This is caused by the corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then doirinn the water heater tank and all hot water lines Contact Sears En for further information concerning an Anode Replacement Kit 9001453 and this Chlorination Treatment If the smelly water persists after the anode replacement and chlo rination treatment we can only suggest that continuous chiori nation and filtering conditioning equipment be considered to eliminate the water problem Do not remove the anode leaving the tank unprotected By doing so all warranty on the water heater tank is voided AIR HOT WATER FAUCETS A WARNING HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possibility of injury under these conditions we recommend the hot water faucet be opened for several mi
38. gas control knob clockwise to OFF posi tion Knob cannot be turned from PILOT to OFF to OFF and call your service technician unless knob is depressed slightly DO NOT FORCE or gas supplier Figure 6 page 17 Figure 6 page 17 10 Replace or close inner door Replace outer door if 5 Wait five B minutes to clear out any gas If you then door does not cover gas contro on off knob or tem _ smell gas STOP Follow B in the safety information perature adjustment knob Figure 9 page 17 above on this label If you don t smell gas go to the 11 At arms length away turn gas contro knob counter next step clockwise 8 to the full ON position Warning 6 Remove or open inner door located below the gas do not use gas control knob to regulate gas control unit flow Figure 8 page 17 7 Find pilot follow metal tube from gas control The pilot 12 At arms length away set the thermostat to desired is located in front of the burner setting The mark A HOT indicative of approximate PILOT BURNER THERMOCOUPLE 120 F is preferred starting point Some local laws may require a lower starting point If hotter water is desired see instruction manual and warning below 8 If you don t smell gas turn knob on gas control counter 13 Replace the outer door if not replaced in step 10 clockwise gt to PILOT position Figure 7 page 17 WARNING Hotter water increases the risk of scald
39. h such local requirements must be satis fied by the installer or end user of the water heater with a locally prescribed temperature pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve For safe operation of the water heater the relief valve must not be removed from it s designated opening or plugged anette ere ee The temperature pressure relief valve must be installed directly into th fitting of the water heater designated for the relief valye Position the valve downward and provide tubing so that any discharge Will only within 6 inches above or at any distance below the structural floor Be certain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 air gap is provided To prevent bodily injury hazard to life or property dam age the relief valve must be allowed to discharge water in quantities should circumstances demand if the dis charge pipe is not connected to a drain or other suitable means the water flow may cause property damage The Discharge Pipe Must not be smaller in siz
40. he temperature pressure relief valve opera tion make sure that 1 no one is in front of or around the outlet of the temperature pressure relief valve discharge line and 2 that the water manually discharged will not cause any property damage because the water may be extremely hot H after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperatur pressure relief valve with a new one 211 Drain Valve Washer Replacement NOTE For replacement use a 42 x s x 4 thick washer available at your riearest hardware store For ordering replace ment washers refer to the Parts Order List section Turn OFF gas supply to water heater Follow Draining instructions e Turning counter clockwise remove the hex cap below the screw handle Remove the washer and put the new one in place Screw the handle and cap assembly back into the drain valve and retighten using a wrench DO NOT OVER TIGHTEN Follow instructions in the Filling The Water Heater section Check for leaks e Follow the lighting instructions in the Lighting section to restart the water heater ASSEMBLY WASHER Housekeeping Vacuum around base of water heater for dust dirt and lint on a regular basis A WARNING INSTALLED IN SUITABLE
41. herwise must be removed if its use inhibits prop er drafting of the water heater Thermally Operated Vent Dampers Gas fired water heaters having thermal efficiency in excess of 80 may produce a rela tively low flue gas temperature Such temperatures may not be high enough to properly open thermally operated vent dampers This would cause spillage of flue gases and may cause carbon monoxide poisoning Vent dampers must bear evidence of certification as complying with the latest edition of American National Standard ANS Z21 68 ANSI Z21 66 amp 67 respectively cover electrically and mechanically actuated vent dampers Before installation of any vent damper consult your local Sears Service Center or the gas utility for further information AWARNING To insure proper venting of this gas fired water heater the correct vent pipe diameter must be utilized Any additions or deletions of other gas appliances on a common vent with this water heater may adversely affect the operation of the water heater Consult the local Sears Service Center or gas utility if any such changes are planned For proper venting in certain installations a larger diameter vent pipe may be necessary Due to great variances in installations unforeseeable by the manufacturer of the water heater you must consult your gas company to aid you in determining the proper venting for your water heater from the vent tables in the latest edition of the N
42. injury Before changing temperature setting see instruction manual TO TURN OFF GAS TO APPLIANCE 1 Set the thermostat to lowest setting by turning the 2 Turn gas control knob clockwise to OFF posi water temperature dial clockwise to its lowest tion Knob cannot be turned from PILOT to OFF temperature setting with arrow on dial as shown DO unless knob is depressed slightly DO NOT FORCE NOT FORCE 3 Replace outer door if removed Operating Instructions cont d Temperature Regulation Due to the nature of the typical gas water heater the water tem peas in certain situations may vary up to 30 F higher or ower at the point of use such as bathtubs showers sink etc This means that when the temperature adjustment dial is set at the mark approximating 120 the actual water temperature at any hot water tap could be as high as 150 F or as low as 90 F Any water heater s intended purpose is to heat water Hot water is needed for cleaning bodies dishes clothing Hot water will present a scald hazard Depewing on the time element and the people involved normal adults children toddlers elderly infirm etc scalding may occur at different temperatures AWARNING HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon conta
43. ions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual AWARNING This water heater shall not be connected to any heating systems or component s used with a non potable water heating appliance A WARNING Toxic chemicals such as used for treatment of boilers or non potable water heating appliances shall never be introduced into a potable water heating system If a water heater is installed in a closed water supply system such as one having a back flow preventer check valve water meter with a check valve etc in the cold water supply means shall be provided to contro thermal expansion Contact the local utility or local Sears Service Center on how to contro this situation NOTE To protect against untimely corrosion of hot and cold water fittings it is strongly recommended that di elec tric unions or couplings be installed on this water heater when connected to copper pipe The illustration shows the attachment of the water piping to the water heater The water heater is equipped with 7 water connections NOTE If using copper tubing solder tubing to an adapter before attaching the adapter to the cold water inlet connec tion Do not solder the cold water supply line directly to the cold water inlet It will harm the dip tube and damage the tank Look at the top cover of the water heater The
44. manently injured by hot water than others These include the elderly children the infirm or physical lyimentally handicapped if anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions tn addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow man ufacturers instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual AWARNING Due to the nature of the typical gas water heater the water temperature in certain situations may be hotter than the thermostat setting Short frequent draws of hot water especially with very cold incoming water can shock the thermostat into brief operation resulting in hotter and hotter layers of water closer to the top of the tank Changes in hot water usage patterns or raising the tem perature differential between the cut on of the thermo stat and the cold water temperature will usually eliminate the problem Troubleshooting Guide cont d Leakage Checkpoints Use this guide to check a Leaking wa
45. mmercial institutional or industrial use or use in residences of two families or more the above warranty coverage for tanks that leak is effective for two years from the date of purchase and the Limited Warranty On Parts below is effective for one year from the date of purchase LIMITED WARRANTY ON PARTS Through one 1 year from the date of purchase when your Sears Kenmore water heater is installed and operated in accordance with the instructions in this manual if a part fails due to a failure in materials or workmanship Sears will furnish a replacement part free of charge If purchaser does not qualify for free installation as provided in the One Year Limited Labor Warranty below there will be a charge for installation ONE YEAR LIMITED LABOR WARRANTY ON WATER HEATER When your Sears Kenmore water heater is installed by Sears or its licensed subcontractor and is operated in accordance with the instructions in this manual Sears will for one year from the date of purchase Install free of charge the replacement water heater as provided by the above Limited Tank Leak Warranty Repair free of charge defects in materials or workmanship of the water heater as provided by the above Limited Warranty on Parts A To obtain warranty service SIMPLY CALL 1 800 4 MY HOME 1 800 469 4663 This warranty applies only while this product is in use in the United States This warranty gives you specific legal rights and you may also have other rights
46. mulated gas in the area Search for odor of gas by sniffing at ground level in the vicinity of the appliance If odor is detected follow steps indicated at For Your Safety on the cover page of this manual then leave the premises This water heater must not be installed directly on car peting Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches 76 2mm in any direction or if the appliarice is installed in an alcove or closet the entire floor must be covered by the panel Failure to heed this warning may result in a fire hazard i A WARNING VENT DAMPERS Any vent damper whether it is operat d thermally or otherwise must be removed if its use inhibits proper drafting of the water heater Thermally Operated Vent Dampers Gas fired water heaters having thermal efficiency in excess of 80 may produce a relatively low flue gas temperature Such tem peratures may not be high enough to properly open ther mally operated vent dampers This would cause spillage of flue gases and may cause carbon monoxide poisoning Vent dampers must bear evidence of certification as com plying with the latest edition of American National Standard ANS Z21 68 ANSI Z21 66 amp 67 respectively cover electrically and mechanically actuated vent dampers Before installation of any vent damper consult your l
47. n should be made of the venting system You should look for e Obstructions which could cause improper venting The com buston and ventilation air flow must not be obstructed e Damage or deterioration which could cause improper vent ing laar of combustion products Rusted flakes around top of water heater AWARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive AWARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation i A WARNING Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation A WARNING If after inspection of the vent system you found sooting or deterioration something is wrong Call the local gas utility to correct the problem and clean or replace the flue and venting before resuming operation of the water heater 20 Burner Inspection A WARNING Do not use this appliance if any part of it has been under water Immediately call a Sears Service Technician to inspect the appliance and to replace the gas control or any part of the burner system which has been under water
48. ne of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addi tion to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufac turers instructions for installation of the valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual A WARNING Soot build up indicates a problem that requires correc tion before further use Turn OFF gas to water heater and leave OFF until repairs are made because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE A WARNING BEFORE LIGHTING PROPANE L P GAS WATER HEATERS Propane L P gas is heavier than air Should there be a leak in the system the gas will settle near the ground Basements crawl spaces skirted areas under mobile homes even when ventilated closets and areas below ground level will serve as pockets for the accumula tion of this gas Before attempting to light or relight the water heater s pilot or turning on a nearby electrical light switch be absolutely sure there is no accu
49. nutes at the kitchen sink before any electrical appliances which are connected to the hot water sys tem are used such as a dishwasher or washing machine If hydrogen gas is present there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened There must be no smoking or open flame near the faucet at the time it is open Troubleshooting Guide cont d Operational Conditions cont d HIGH TEMPERATURE SHUT OFF SYSTEM This water heater is equipped with an automatic gas shut off sys tem The high temperature shut off is built into the gas control valve This system shuts off the gas supply to the water heater burners when high water temperatures are present It is non resettable If the high temperature shut off activates the gas con trol valve must be replaced If this were to occur turn OFF the entire gas supply to the water heater Contact the Sears Service Center i A WARNING Should overheating occur or the gas supply fail to shut off turn OFF the manual gas control valve to the appliance NOT ENOUGH OR NO HOT WATER Check the manual gas shut off valve to be sure it is open Check the pilot flame It may have gone out All models have an opening behind the outer door for viewing the pilot If the pilot is not lit follow the Lighting instructions in this manual or located above the gas control valve on the water heater to relight the pilot
50. ocal Sears Service Center or the gas utility for fur ther information A WARNING The appliance and its individual shutoff valve must be dis connected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of pound per square inch 3 5kPa e The appliance must be isolated from the gas supply pip ing system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping sys tem at test pressures equal or fess than pound per square inch 3 5kPa AWARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigera tor and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive A WARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation Safety Precautions continued on page 4 Safety Precautions A WARNING The water heater with draft hood installed must be prop erly vented to a chimney which terminates outdoors Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation explosion or asphyxiation AWARNING Minimum clearances between the water heater an
51. on Turn the water temperature dial clockwise N to decrease the temperature or counterclockwise to increase the temperature PILOT LIGHTING Set here before attempting to light pilot A HOT Is a thermostat setting of approximately 120 F which will supply hot water at the most economical temperatures The temperature adjustment knob can be turned lower than HOT if desired A Is a thermostat setting of approximately 130 F B Is a thermostat setting of approximately 140 F C Is a thermostat setting of approximately 150 F VERY HOT Is a thermostat setting of 160 F Ir is recommended that the dial be set lower whenever possible NOTE Water temperature range of 120 140 F recom mended by most dishwasher manufacturers A WARNING Should overheating occur or the gas supply fail to shut off turn OFF the manual gas control valve to the appliance Service and Adjustment Tank Sediment Cleaning Sediment build up on the tank bottom may create varying amounts of noise and if left in the tank will cause premature tank failure In some water areas you may not be able to drain all sediment deposits by simply draining the tank In these cases Mag Erad part no 23600 can be used to help remove the sedi ment deposits This may be ordered from the Sears Service Center For ordering refer to the Parts Order List section Venting System Inspection At least once a year a visual inspectio
52. r the relief valve must not be removed from it s designated opening or plugged The temperature pressure relief valve must be installed directly into the fitting of the water heater designated for the relief valve Position the valve downward and provide tubing so that any dis charge will exit only within 6 inches above or at any distance below the structural floor Be certain that no contact is made with any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Excessive length over 30 feet or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve No valve or other obstruction is to be placed between the relief valve and the tank Do not connect tubing directly to discharge drain unless a 6 air gap is provided To prevent bodily injury haz ard to life or property damage the relief valve must be allowed to discharge water in quantities should circumstances demand If the discharge pipe is not connected to a drain or other suitable means the water flow may cause property damage The Discharge Pipe Must not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Must not be plugged or blocked Must be of material listed for hot water distribution Must be installed so as to allow complete drainage of both the temperature pressure relief valve and the discharge pipe Mus
53. r ser vicing and proper operation of the water heater A WARNING This water heater must not be instalied directly on carpeting Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches 76 2mm in any direction or if the appliance is installed in an alcove or closet the entire floor must be covered by the panel Failure to heed this warning may result in a fire hazard A WARNING Minimum clearances between the water heater and com bustible or non combustible construction are at the sides and rear 4 at the front and 6 from the vent pipe Clearance from the top of the jacket is 18 on most models Note that a lesser dimension may be allowed on some models Refer to the label on the water heater adjacent to the gas control valve for all clearances VENTILATION OPENINGS WITH 8 RECTANGULAR AIR DUCT A WARNING A gas water heater cannot operate properly without the cor rect amount of air for combustion Do not install in a confined area such a closet unless you provide air as shown in the Facts to Consider About the Location section Never obstruct the flow of ventilation air If you have any doubts or questions at all call your gas company Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE
54. rol knob to the OFF position CLOSE the cold water inlet valve to the water heater OPEN a nearby hot water faucet and leave open to allow for draining Connect a hose to the drain valve and terminate to an adequate drain OPEN the water heater drain valve to allow for tank draining NOTE If the water heater is going to be shut down and drained for an extended period the drain valve should be left open with hose connected allowing water to terminate to an adequate drain Close the drain valve e Follow instructions in the Filling The Water Heater section Follow the lighting instructions in the Lighting section to restart the water heater Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be manually operated at least once a year TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE Failure to install and maintain a new properly listed tempera ture pressure relief valve will release the manufacturer from any claim which might result from excessive temperature or pressure A WARNING If the temperature pressure relief valve on the appliance weeps or discharges periodically this may be due to thermal expansion Your water heater may have a check valve installed in the water line or a water meter with a check valve Consult the Sears Service Center for further informa tion Do not plug the temperature pressure relief valve A WARNING When checking t
55. s supplier call the fire depart ment A WARNING DO NOT force the gas control knob Use only your hand to push it down to light the pilot or to turn it to ON OFF or PILOT Never use a tool such as a fever wrench or pli ers Do not hit or damage the knob A damaged knob may result in an explosion and serious injury If you have problem turning the knob call the gas supplier immediately CHECK FOR LEAKS Be sure to check all your gas pipes for leaks before lighting your water heater Use a soapy water solution not a match or open flame Check the factory gas fittings after pilot is lit and gas con trol knob is still in PILOT position Then check the fittings when the main burner is turned ON Use a soapy water solu tion for this too i MANIFOLD COVER Operating Instructions cont d Lighting label on the water heater as it appears above the thermostat FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by of t reach 5 lier call the fi hand When lighting the pilot follow these instructions d reach your gas supplier call the fire exactly C Use only your hand to push in or turn the gas control for gas Be sure to smell next to the floor because turn by hand don t try
56. s to produce a sizzling or frying noise Excessive condensation can cause pilot outage due to water run ning down the flue tube onto the main burner and putting out the pilot Because of the suddenness and amount of water condensation water may be diagnosed as a tank leak After the water in the tank warms up about 1 2 hours the condition should disappear Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up An undersized water heater will cause more condensation The water heater must be sized properly to meet the family s demands for hot water including dishwashers washing machines and shower heads Excessive condensation may be noticed during the winter and early spring months when incoming water temperatures are at their lowest Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor SMOKE ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start up This is due to burning off of oil from metal parts and will disappear in a short while 22 THERMAL EXPANSION Water supply systems may because of high line pressure fre quent cut offs the effects of water hammer and others have installed devices such as pressure reducing valves check valves back flow preventers etc to control these types of problems When
57. snsenstaccasanenneserasesceneensanes 21 Drain Valve Washer Replacement cccssssssssssssssssssscscosscossnceosscesescoseneassacassnsanencnecosaneneasuessanensenoaenssucagensossnssesacscanensonsansecooss 21 Housekeeping ssssossenssusosencasauensonsates 21 Service viessesssessessseressceesreneersrees 7 21 6 0 22 25 Up ten beraasdsttterentandteeeeeeseseeeeean 22 23 i 7 2 7 aiiai iaaiiai 22 22 23 Strange Sounds 23 23 24 Smelly Water cscsccsscsssesssssseseneserseree 7 23 23 24 24 Water is Too 7 7 24 Leakage Checkpoint cccsssscssscssseseessseesssssssesssneessncaesnenssassstscsececseenessssssssacsnsnssseusssnnanecussvenssnesssnsensnsssossnsencauaseneanenssecseneaeagaes 25 0 ann enacmee eats 26 27 Customer Responsibilities Thank You for purchasing a Sears water heater Properly installed and maintained it should give you years of trouble free service If you should decide that you want the new water heater professionally installed by Sears call the local Sears Service Center or any Sears store They will arrange for prompt quality installation by Sears authorized contractors Abbreviations Found In This Instruction Manual A G A American Gas Association A N S I American National Standards Institute A WARNING This gas fired water heater is design certified by the American Gas Association Laboratories under American
58. sted equipment or mate rials as meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems and the latest edition of ANSI Z21 22 and the code require ments of ASME If replaced the valve must meet the require ments of focal codes but not less than a combination tempera ture and pressure relief valve certified as meeting the require ments for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21 22 by a nationally recog nized testing laboratory that maintains periodic inspection of production of listed equipment or materials The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater 150 Ibs sq in and a discharge capacity not less than the water heater input rate as shown on the model rating plate Electric heaters watts divided by 1000 x 3415 equal BTU Hr rate Your local jurisdictional authority while mandating the use of a temperature pressure relief valve complying with ANSI Z21 22 and ASME may require a valve model different from the one furnished with the water heater Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a locally pre scribed temperature pressure relief valve installed in the desig nated opening in the water heater in place of the factory fur nished valve For safe operation of the water heate
59. t terminate at an adequate drain Must not have any valve between the relief valve and tank A WARNING The temperature pressure relief valve must be manually operated at least once a year Caution should be taken to ensure that 1 no one is in front of or around the outlet of the temperature pressure relief valve di line and 2 the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot If after manually operating the valve it fails to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE Do not cap or plug 6 AIR GAP FLOOR DRAIN RELIEF VALVE OPENING At the time of manufacture this water heater was provided with a combination tem perature pressure relief valve listed as complying with the standard for relief valves and automatic gas shut off devices for hot water supply systems ANS 221 22 For safe operation of the water heater the relief valve must not be removed from its designated point of installation or plugged Your local jurisdictional authority while mandating the use of a temperature pressure relief valve complying with ANSI Z21 22 and ASME may require a valve model diff
60. ter heater Many suspected Leakers are not leaking tanks Often the source of the water can be found and corrected If you are not thoroughly familiar with your local gas codes your water heater and safety practices contact the Sears Service Center to check the water heater May 0 UAA DS 25 A CAUTION Read this manual first Then before checking the water heater make sure the gas supply has been turned OFF and never turn the gas ON before the tank is completely full of water A CAUTION Never use this water heater unless it is completely filled with water To prevent damage to the tank the tank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater Water at the draft hood is water vapor which has con densed out of the combustion products This is caused by a problem in the vent Contact the Sears Service Center Condensation may be seen on pipes in humid weather or pipe connections may be leaking The primary anode rod fitting may be leaking 9 The temperature pressure relief valve may be leaking at the tank fitting Q Water from a drain valve may be due to the valve opened slightly The drain valve may be leaking at the tank fitting Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area Combustion products contain water
61. the gas control valve of the water heater can be accomplished by either of the two methods shown A WARNING Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure that all gas pipe is clean on the inside To trap any dirt or foreign material in the gas supply line a drip leg sometimes called a sediment trap must be incorporated in the piping The drip leg must be readily accessible Install in accordance with the Gas Piping section Refer to the latest edition of the National Fuel Gas Code ANSI Z223 also referred to as NFPA 54 15 GAS PIPING WITH FLEXIBLE CONNECTOR FLEXIBLE GAS CONNECTOR LABELED AS COMPLYING WITH ANSI STANDING GROUND JOINT UNION Optional GAS CONTROL VALVE DRIP LEG Sediment trap GAS PIPING WITH ALL BLACK IRON PIPE TO GAS CONTROL GROUND JOINT UNION Optional GAS CONTROL ALVE DRIP LEG Sediment trap Installation Instructions cont d Installation Checklist BEFORE LIGHTING THE PILOT Check the gas lines for leaks a Use a soapy water solution DO NOT test for gas leaks using a match or open flame b Brush the soapy water solution on all gas pipes joints and fittings 6 Check for bubblin Turn OFF gas 1 d Recheck for leaks e Rinse off soapy solution and wipe dry soap This means you have a leak make the necessary rep
62. these devices are not equipped with an internal by pass and no other measures are taken the devices cause the water sys tem to be closed As water is heated it expands thermal expan and closed systems do not allow for the expansion of heat ed water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The tempera ture pressure relief valve is not intended for the constant relief of thermal expansion This is an unacceptable condition and must be corrected It is recommended that any devices installed which could create a closed system have a by pass and or the system have an expan sion tank to relieve the pressure built by thermal expansion in the water system Expansion tanks are available for ordering through the Sears Service Center Contact the local plumbing inspector water supplier and or the Sears Service Center for assistance in controlling these situations Thermal Expansion Tank Specifications Tank piy Dimensions in Inches Pipe Fitting In Gallons Diameter Length On Tank 153 331020 2 8 inches 12 inches 7 Male 153 331050 5 11 inches 14 inches Male Expansion Tank Sizing Chart Inlet Water Pressure Water Heater Capacity Gallons Expansion 40psi
63. to repair it call a qualified ser Some gas is heavier than air and will settle on the floor vice technician Force or attempted repair may result WHAT TO DO IF YOU SMELL GAS in a fire or explosion Do not try to light any appliance D Do not use this appliance if any part has been under _ Do not touch any electric switch do not use any water Immediately call a qualified service technician phone in your building to inspect the appliance and to replace any part of the Immediately call your gas supplier from a neighbor s control system and any gas control which has been phone Follow the gas supplier s instructions under water LIGHTING INSTRUCTIONS 1 STOP Read the safety information above on this label 9 Push in control knob all the way and hold down 2 Remove outer door Immediately light the pilot with a match Continue to 3 Set the thermostat to lowest setting by turning the hold control knob in for about one 1 minute after water temperature dial clockwise to its lowest the pilot is tit Release knob and it will pop back up temperature setting with arrow on dial as shown DO Pilot should remain lit If it goes out repeat steps 3 NOT FORCE through 8 if knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries depress and turn the gas control knob clockwise 4 Turn
64. which vary from state to state SEARS ROEBUCK AND CO Dept 817 WA Hoffman Estates IL 60179 Sears Installation Warranty Sears Installation Policy In addition to any warranty extended to you on the Sears merchandise involved which warranty becomes effective the date the merchandise is installed should the workmanship of any Sears arranged installation prove faulty within one year Sears will upon notice from you cause such faults to be corrected at no additional cost to you If you want this heater profession ally installed by Sears contact your Sears Salesperson They will arrange for prompt quality installation For the repair or replacement parts you need detivered directly to your home All installation labor arranged by Sears shall be performed in a neat work manlike manner in accordance with generally accepted trade practices Further all installations shall comply with all local laws codes regulations and ordinances The customer shall also be protected during installation by insurance relating to property damage Worker s Compensation and Public Liability If you want this water heater professionally installed by Sears contact your Salesperson They will arrange for prompt quality installation by Sears authorized contractors For in home major brand repair service Call 24 hours a day 7 days a week Call 6 am 14 pm CST 7 days a week SS 41 800 4 MY HOME 4 800 366 PART HomeCentral 1 800 469 4663 1 800

Download Pdf Manuals

image

Related Search

Related Contents

Sony Walkman SRF-M48RDS User's Manual  WinCamD-LCM Use With M2DU Stage  Sharp UX-P400 User's Manual    LA PRATIQUE DU SACREMENT DE PENITENCE Pour bien se  温度カードロガー(2ch)  User's Guide Bedienungsanleitung Mode d'emploi Manuale  User Manual - Automatikprodukter  Aiphone JKW-IP LAN IP adaptor for JK  Bedienungsanleitung  