Home

Insignia NS-55E560A11 Flat Panel Television User Manual

image

Contents

1. 40 mil gt 5 mil 55 mil 4 5 FEET User s Guide 7 In the context of the illustration below a mil repre sents the minimum bar code element width Mea surements are based on HD models set with the standard 28 scan width as opposed to the Half Angle setting of 14 Reference the PowerScan Pro gramming Manual for more information about the Half Angle feature NOTE Specifications are subject to change without notice Figure 4 Depth of Field HD Depth of Field Paper Labels HD decoded model Code 39 8 PowerScan Scanner surements are based on LR models set with the a 14 scan width as opposed to the alternate Full Angle setting of 28 Reference the PowerScan Pro gramming Manual for more information about the Half Angle feature In the context of the illustration below a mil repre 7 sents the minimum bar code element width Mea NOTE Specifications are subject to change without notice Figure 5 Depth of Field LR Depth of Field Paper Labels LR decoded model Code 39 100 mil 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 FEET User s Guide 9 In the context of the
2. any components in the optics cavity Opening or servic ing any part of the optics cavity by unauthorized CAUTION personnel may violate laser safety regulations Radio Frequency Interference This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada User s Guide 13 Troubleshooting You can isolate problems with your scanning system by performing these checks refer to Figure 9 14 1 If your scanner s cable is designed to receive Power Off the Terminal P O T it will not operate unless it is connected to a working host terminal that is powered on Ensure that the interface cable is securely attached to the host Consult your technical support manager or refer to your host system manual to identify the proper connection for the scanner If an external power supply is used verify that it is securely connected to the interface cable and AC outlet Also ensure that the power supply is the correct voltage rating for your area Check to see that the interface cable is securely connected at the scanner handle Push the connector in to assure
3. 0825 EN50082 1 EN60950 Equipment Type Bar Code Scanning Equipment Product PowerScan Bar Code Scanner PowerScan LR Bar Code Scanner PowerScan XLR Bar Code Scanner URR LAL Charles W Vanlue Nigel Davis Director Corporate Quality Vice President PSC Inc Europe Middle East amp Africa 959 Terry Street PSC Bar Code Ltd Eugene OR 97402 Axis 3 Rhodes Way U S A Watford England WD24YW 6 Asia Pacific Italy PSC Hong Kong PSC S R L Hong Kong Vimercate Ml Italy Telephone 852 2 584 6210 Telephone 39 0 39 62903 1 Fax 852 2 521 0291 Fax 39 0 39 685496 Australia Japan PSC Asia Pacific Pty Ltd PSC Japan K K North Ryde Australia Shinagawa ku Tokyo Japan Telephone 61 0 2 9878 8999 Telephone 81 0 3 3491 6761 Fax 61 0 2 9878 8688 Fax 81 0 3 3491 6656 France Latin America PSC S A R L PSC S A INC LES ULIS Cedex France Miami Florida USA Telephone 33 01 64 86 71 00 Telephone 305 539 0111 Fax 33 01 64 46 72 44 Fax 305 539 0206 Germany United Kingdom PSC GmbH PSC Bar Code Ltd Darmstadt Germany Watford England Telephone 49 0 61 51 93 58 0 Telephone 44 0 1923 809500 Fax 49 0 61 51 93 58 58 Fax 44 0 1923 809 505 www pscnet com Corporate Headquarters PSC Inc PSC Inc L 959 Terry Street Portland OR Eugene OR Telephone 503 534 3553 Printed on recycled paper Telephone 54
4. 1 683 5700 Fax 503 534 3555 Fax 541 686 1702 2001 PSC INC R44 2094 Rev E Printed in USA 6 01
5. Cosc PowerScan Handheld Bar Code Scanner Models SR HD LR and XLR User s Guide PSC Inc 959 Terry Street Eugene Oregon 97402 Telephone 541 683 5700 Fax 541 345 7140 All rights reserved No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc Owners of PSC Inc s products are hereby granted non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained on this documentation and shall ensure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting PSC Customer Administration Elec tronic versions will either be downloadable from the PSC web site www pscnet com or provided on appropriate media If you visit our web site and would like to make comments or suggestions about this or other PSC publications please let us know via the Contact PSC page Disclaimer Reasonable measures have been taken to ensure that the information included in this manual is complete and accurate However PSC reserves the right to change any specification at any time without prior notice PSC and the PSC logo are registere
6. d trademarks of PSC Inc All other trademarks and trade names referred to herein are property of their respective owners Table of Contents Unpacking and Inspecting Your 00 3 4 How to Cal Lacock cecasti seeks tases tat ae ee tela ters 6 Scanning RANGE wai cece eee he nate 7 Active Symbologies 5 s s23 c2 52 5 cites eae dee dadaceet ete 11 Enhanced Scanning for Hard to Read Bar Codes 11 Test Your Scanner c e test We a tetirashd tcp rces eatceatat aadtveagttt 12 BAS CN CaM OMS oppo taceat leat ais eat tc i 13 Radio Frequency 01 0000 13 Troubleshooting sisted ache ie celta eee eee 14 User s Guide 1 NOTES PowerScan Scanner Unpacking and Inspecting Your Scanner After unpacking your new scanner check the contents of the ship ping carton to ensure all the items you ordered are included PowerScan handheld scanner Interface Cable Power Supply if you ordered one User s Guide this manual Programming Guide Optional Accessories that you ordered The PowerScan handheld bar code scanner can be purchased with or without accessory kits If your package contains wrong or missing components contact your place of purchase If there are damaged components immediately file a claim with the carrier You may want to save your packing material in case you need to ship the scanner at some later time Manuals for the PowerScan scanner are available on our website See the back c
7. illustration below a mil repre sents the minimum bar code element width Mea surements are based on XLR models set with a 10 scan angle width NOTE Specifications are subject to change without notice Figure 6 Depth of Field XLR Depth of Field Paper Labels XLR decoded model Code 39 100 mil 1 2 3 4 5 6 7 8 9 10111213 1415 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 FEET 10 PowerScan Scanner Active Symbologies The active enabled bar code symbologies in the factory defaults are e Code 39 C39 e Code 128 C128 Interleaved 2 of 5 1 2 of 5 Your scanner should be pre programmed with these standard factory default settings unless it was shipped to you programmed with unique customer con figuration settings you or another user have made changes to scanner program ming Enhanced Scanning for Hard to Read Bar Codes Decoded scanners can be programmed to decode extremely poor quality bar codes by activating advanced Quadralogic Decoding To select this feature see the PowerScan Scanner Programming Guide available from your dealer or you can download the manual from our website Scanner programming can also be performed using your PC and the Configurator Express On Screen Programming tool also available from your dealer User s Guide 11 Test Your Scanner The bar code below Figure 7 is provided to tes
8. nner 4 PowerScan Scanner Figure 1 Installing the Scanner User s Guide How to Scan Figure 2 illustrates some tips to help get the best scanning results 1 The scanner must be pointed at a slight angle to the bar code Do not hold the scanner perpendicular to the bar code 2 The laser beam must cross the entire bar code The scanner cannot correctly read if the entire bar code is not scanned Figure 2 Scanning Tips 6 PowerScan Scanner Scanning Range There are currently four different model types for this scanner Depending upon the model type of your scanner you ll need to hold the unit at a given distance from the bar code to achieve optimum scanning results The following diagrams provide range of field infor mation for each of the models when scanning grade A Code 39 bar codes Standard Range SR High Density HD Long Range LR and Extra Long Range XLR In the context of the illustration below a mil repre sents the minimum bar code element width Mea surements are based on SR models set with the standard 28 scan width as opposed to the Half Angle setting of 14 Reference the PowerScan Pro gramming Manual for more information about the NOLE Half Angle feature Specifications are subject to change without notice Figure 3 Depth of Field SR Depth of Field Paper Labels SR decoded model Code 39
9. over for our web address NOTE User s Guide Installation Refer to Figure 1 and follow these steps to install the scanner Consult your host terminal manual to determine if power must be turned off before connecting peripheral devices such as the scanner 1 Should you need to disconnect the interface I F cable from the scanner loosen the Phillips head screw at the bottom of the handle and rotate the cable restraint clip away from the cable to release it Reverse this procedure to connect the cable AN Do not attempt to pull the End Cap off as this may damage the scanner CAUTION 2 Connect the I F cable to the proper port on the host terminal 3 If your system requires an AC DC adapter to power the scanner connect the adapter s power cord at the I F connec tor Note In most cases the scanner uses Power Off the Ter minal P O T and does not require this step Contact your PSC dealer if you re not sure if an AC DC adapter should be used with your system 4 Connect the AC DC adapter at the wall outlet P O T units skip this step 5 Verify operation point at a flat surface and pull the trigger A red beam should be visible Scan a sample bar code and confirm that the scanner reads the bar code by beeping and or sending the data to the host terminal Power Supply The scanner requires either a Listed Class 2 or Listed LPS power source which supplies power directly to the sca
10. t your scanner s abil ity to read a typical Code 39 label Figure 7 Code 39 Bar Code Sample E 5 6 Figure 8 Scanner Labeling Complies with 21CFR 1040 of FCC Rules re list sted i ER RADATONS Bry As LE 5 6 s 1 covero BY ONE OR MORE OF THE FOLLOWING PATENTS Other pateris percing CAUTION LASER RADINTION WHEN OPEN AVOD EXPOSURE TO BEAN Figure 8 above shows label placement ONLY For actual regulatory patent and other applicable infor mation view the labels on the product itself or call NOTE your nearest sales or service representative 12 PowerScan Scanner Laser Cautions The PowerScan bar code scanner is certified in the U S to conform to the requirements of DHHS CDRH 21CFR Subchapter J for Class II laser products SR and LR and Class IIIa XLR Class II and Ila products are not considered to be hazardous The scanner contains a Visible Laser Diode VLD at a wavelength of 650 670 nanometers and is designed so that there can be no human access to harmful levels of laser light during normal operation user maintenance or during pre scribed service operations If the scan pattern is a single dot when depressing AN the trigger discontinue operation and return the unit to the factory Exception When using Marker Beam Mode a single aiming dot is projected CAUTION momentarily Do not attempt to open or otherwise service
11. that it is firmly seated Use a Phillips head screwdriver to ensure that the screw at the bottom of the scanner is fully tightened but do not overtighten If after checking all connections the scanner still fails to function properly exchange the power supply with a known good power supply Ensure that the scanner s interface type is compatible with the host terminal by consulting your POS system manual and or the PowerScan Scanner Programming Guide Verify that the bar codes you are scanning are of satisfactory quality Bar code label verifiers are available from your dealer if you need precise reporting of bar code details Bar codes that are damaged wrinkled smudged or torn may cause the scanner to read poorly or not at all If bar code quality seems to be the problem check to see if the scanner will read a known good bar code see Figure 7 You may also want to modify the programmable setting for advanced Quadralogic decoding see the section in this manual titled Enhanced Scanning for Hard to Read Bar Codes PowerScan Scanner Figure 9 Troubleshooting the Scanner ee anti Progi N yW acua a 16 NOTES PowerScan Scanner DECLARATION OF CONFORMITY PSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards Directives EMC 89 336 EEC Low Voltage 73 23 EEC Standards EN55022 B EN6

Download Pdf Manuals

image

Related Search

Related Contents

Culture O Centre – Parc de matériel scénique Manuel d`utilisation  S202 GSM Mobile Phone  Owners Manual  Partenaires dans le transfert d`apprentissage  User Manual - Fischer Panda Generators Inc.  Italiano, 3.4 MB  RSI - Richter Chemie    SPL A4 SPL A3 SPL A2  

Copyright © All rights reserved.
Failed to retrieve file