Home
Hunter Fan 42751-01 Fan User Manual
Contents
1. IS Owner s Guide and Installation Manual For reference also attach your receipt or a copy of your receipt to the manual ty ia Type 2 Mode SINCE 1886 Form 42751 01 20090903 2009 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan 2 Installing the Ceiling Plate disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the s
2. 1 Check to make sure wattage of light bulbs installed match the specifications on the light socket Problem If the light on this fan shuts off suddenly 1 Turn the power to the fan off at the wall switch If you need parts or service assistance please call Wait 30 seconds then resume power to the fan 888 830 1326 In Canada call 1 866 268 1936 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Pkwy 400 Memphis Tennessee 38016 42751 01 09 03 09 Hunter Fan Company
3. Steps 7 1 7 3 Housing 7 4 Turn the housing counterclockwise until the housing assembly Assembly Aa screws are firmly situated in the narrow end of the keyhole slots Screw a P Install the remaining screw into the housing Tighten all three screws firmly A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling 7 5 If you want to install the light fixture proceed with step 7 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 7 14 Once you have uninstalled the light fixture continue with step 7 6 10 42751 01 09 03 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued 7 6 To attach the lower switch housing connect the upper plug 7 7 connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Place the lower switch housing assembly over the upper switch lt ___ Plug Connector housing Align
4. You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 Preparing the Fan Site Before you begin installing the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 42751 01 09 03 09 Hunter Fan Company 2 Installing the Ceiling Plate A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such
5. Profile Standard or Angled mounting The steps in this manual include instructions for all three Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance Support Brace Low Profile ad Mounting Style Outlet Box Low Profile Mounting fits close to the ceiling recommended for ceilings less than 8 feet high 3 42751 01 09 03 09 Hunter Fan Company A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools
6. as a tag to the service panel 2 1 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 in diameter 2 2 Your fan comes with four neoprene noise isolators Isolators Position the isolators between the ceiling plate and ceiling by inserting the raised areas on each isolator into the holes in the ceiling plate 2 3 Thread the lead wires from the outlet box down through the hole in the middle of the ceiling plate 2 4 Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure For proper alignment use slotted holes directly across from each other Note The isolators should be flush against the ceiling 2 5 Place a flat washer on each of the two 3 wood screws and pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Flat Washer 3 Wood Screw femmes F HUN NUNEEEEOUU NUN be 5 42751 01 09 03 09 Hunter Fan Company Isolator Ceiling Plate gt K A a ee a ae a TT iy e T Steps 2 3 2 5 a _ For Angled Ceilings Be sure to orient the ceiling plate so that the arrows printed on the ceiling plate are pointing toward the ceiling pea
7. the N a i B10 j _ Candelabra Base 60 Watt Maximum R _ _ Metal Rod r a Metal Disk end of the extra chain Glass Bowl a Cover Plate Breakaway wy Finial Connector ee 12 42751 01 09 03 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 7 14 To uninstall the light fixture first disconnect the plug connectors 7 15 between the black wire and the red wire Disconnect the plug connectors between the two white wires Uninstall the connector and washer from the end of the light fixture inside the lower switch housing Unscrew the threaded rod of the light fixture from the lower switch housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the hole Install the dummy terminals included in the sack parts on the two disconnected wires in the lower switch housing Install the switch housing cap and plug button to the lower switch housing Once you have uninstalled the light fixture continue with step 7 6 Male Dummy Terminal Cap Female Dummy Terminal Plug Button 13 Y j 4 Lower Switch TT Steps 7 17 7 1
8. the side screw holes in the upper and lower switch Steps ey housings Attach the lower switch housing to the upper switch housing with three housing assembly screws Lower Switch Housing Note In compliance with US federal energy regulations this ceiling fan contains a device that restricts the light kit toa 8 acai Plug T maximum of 190 Watts Exceeding that limit or the marked Connector limit on this product may result in fire hazard or improper Detail operation Housing Assembly Screw lI 42751 01 09 03 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Installing the Glass Bowl 7 8 First install B10 candelabra bulbs 60 Watt Maximum into the sockets 7 9 Thread the light and fan pull chains through the hole in the center of the glass bowl Then thread the light pull chain through the hole in the center of the cover plate 7 10 Thread the fan pull chain through the grommet hole in the side of the cover plate 7 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 7 12 Thread the light pull chain through the finial and screw the finial onto the threaded rod end until tight 7 13 Attach the extra pull chains included to the light and fan pull h the plastic break tor Y find th C ains using e pias iC rea away connec ans ou may n e Light Bulbs plastic breakaway connector on
9. 9 Threaded Rod TE Step 7 20 42751 01 09 03 09 Hunter Fan Company 8 1 8 Operating and Cleaning Your Ceiling Fan Turn on electrical power to the fan 8 2 The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off 8 3 8 4 8 5 e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector The light pull chain controls the power to the light fixture The chain has two settings ON and OFF Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing clo
10. e ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections 4 6 Turn the splices upward and push them carefully back through the ceiling plate into the outlet box 4 7 Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 7 42751 01 09 03 09 Hunter Fan Company 5 1 5 2 5 3 5 4 5 5 5 Installing the Canopy and Canopy Trim Ring Holding the canopy raise the fan off the hook Step 5 2 Ceiling Plate Align the slots in the canopy with the tabs on the ceiling plate Raise the canopy over the ceiling plate Rotate the canopy clockwise until the tabs on the ceiling plate totally engage with A A I I the slots in the canopy i Partially install the three canopy screws into the canopy one at a Ca ian time Once all three screws are in tighten them angpy J Ring Using both hands push the canopy trim ring up to the top of the canopy The canopy trim ring will snap and lock into place Should you need to remove the canopy trim ring follow these steps 1 Locate the tab indicators small bumps on top of tabs 2 Press firmly on opposite sides of the ring toward the canopy The tabs will flex out releasing the trim ring from the canopy Steps 5 4 5 5 Canopy 8 42751 01 09 03 09 Hunter Fan Compa
11. ervice panel All wiring must be in accordance with national and local electrical Table of Contents 1 e Getting Ready 3 e Assembling the Fan 4 Hanging and Wiring the Fan 5 Installing the Canopy and Canopy ARINE codes and ANSI NFPA 70 If you are unfamiliar with wiring use a 6 Assembling the Blades qualified electrician 7 e Completing Your Installation With e To reduce the risk of personal injury do not bend the blade or Without a Light Fixture attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls 8 Operating and Cleaning Your Ceiling Fan 9 Troubleshooting 2009 Hunter Fan Company 2 42751 01 09 03 09 Hunter Fan Company Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outlet Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 3 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of three ways depending on ceiling height and your preference Low
12. k 3 Assembling and Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Unbundle the wires from the fan For Standard or Angled mounting 3 2 To assemble fan to hang down from a flat or angled ceiling insert the downrod through the canopy and canopy trim ring Feed the wires from the fan through the downrod 3 3 Loosen the square head setscrew on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the setscrew with a wrench or pliers Skip to Step 3 7 A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the setscrew from the adapter 3 5 Place the low profile washer lip up into the canopy Be sure the green ground wire is pointing up toward the ceiling 3 6 Align the holes in the washer with the holes in the adapter Assemble securely with three low profile screws 3 7 Raise the fan and place the hook on the ceiling plate through the U shaped hole in the rim Step 3 7 U shaped Hole 6 Steps 3 2 3 3 lt lt Canopy Can
13. ny 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Install the grommets into the blades by hand Step 6 1 Detail 6 2 Place each blade between a blade iron and medallion Install three blade screws to attach the medallion to the blade iron Repeat for all blades 6 3 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet screws Use without grommet Blade Mounting Screw 42751 01 09 03 09 Hunter Fan Company Steps 6 2 6 4 7 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the included light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws
14. opy Trim Ring Setscrew Low Profile Screw 42751 01 09 03 09 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Wall switches are not included Select an acceptable general use switch in accordance with national and local electrical codes 4 1 Before attempting installation make sure the power is still off 4 2 To connect the wires hold the bare metal leads together and place a a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided Wire Connector Dual Switch Wiring 4 3 Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the green ground wire from the fan 4 4 Connect the white wire grounded from the ceiling to the white wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring e The black wire ungrounded from the ceiling to the black wire ungrounded from the fan e The black white wire ungrounded from the fan to the wire ungrounded for the wall switch Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wir
15. th Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Turn the fan off and let it come to a complete stop Slide the reversing switch on the fan to the opposite position Restart fan 42751 01 09 03 09 Hunter Fan Company 14 gt Reversing Switch In warm weather use downward air flow pattern In cold weather use upward air flow pattern 9 Troubleshooting Problem Nothing happens fan does not move 1 a 5 6 Problem Noisy operation Turn power on replace fuse or reset breaker Loosen canopy check all connections according to the wiring the Check the plug connection in the switch housing Push motor reversing switch firmly left or right to ensure that the switch is engaged Pull the pull chain to ensure it is on Remove the shipping bumpers 1 Tighten the blade assembly screws and blade iron armature screws 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit 2 Tighten all blade iron screws and instructions to balance the fan 3 Turn power off support fan very carefully and check that the hanger ball is properly seated Problem Lights dim when turned on or do not turn on