1. To execute the selected function use the Adjust Switches in the Table l overleaf W You can save the your geometry and colour Sample of EasyMenu settings Refer to SAVE below W To clear the EasyMenu either push the status switch again or wait for 10 seconds SAVE If the function AUTO SAVE is ON you can save automatically at clearing the EasyMenu Table l COLOR BALANCE USER 6500K 9300K makes the Green and Blue stronger o CONTRAST makes the Contrast intensity makes the Contrast intensity weaker stronger xy BRIGHTNESS makes Brightness darker makes Brightness brighter H SIZE shrinks expands e horizontally E horizontally H POSITION moves the position moves the position D to the left to the right Es V SIZE shrinks vertically expands vertically amp V POSITION moves the position moves the position down up e ROTATION rotates counter clo rotates clockwise ckwise yi PINCUSHION curves the left right curves the left right sides inward sides outwards FA TRAPEZOID shrinks the top a expands the top side and expands side and shrinks the bottom side the bottom side PIN BALANCE curves the lift right curves the left right Ci sides to the left sides to the right PARALLELOGRAM tilts to the right tilts to the left Lj i E U RI RECALL recalls the factory preset modes Refer to Page 1 7 STANDARD SETTINGS a COLOR SELECT c
2. Green and Yellow Earth Blue Neutral Brown Live As these colours may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured GREEN and YELLOW must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol 2 or coloured GREEN or GREEN and YELLOW The wire coloured BLUE must be connected to the terminal marked with the letter N or coloured BLUE or BLACK The wire coloured BROWN must be connected to the terminal marked with the letter L or coloured BROWN or RED Ll A Install the monitor in the following way taking care to maintain safety am FRONT VIEW REAR VIEW E n Front Cover Rear Cover CRT Surface Signal Input Connector Power Switch AC Inlet Control Panel HERES Power Cord Tilt amp Swivel Base T USB Slot to a receptacle of to the host computer gt for the optional USB HUB Module the correct voltage 1 Installation Install the monitor on a horizontal base 2 Power Cord Connection Make sure of using the power cord meeting the safety standard of the country in which you are using the monitor Insert the connector of a power cord to the AC Inlet of the monitor 9 Insert the plug of the power cord to a power point of the correct voltage 3 Signal Cable Connection Insert the Signal Input Connector of the monitor to the host computer with attention to it s suitabi
3. B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Instructions to Users This equipment complies with the requirements of FCC Federal Communication Commission equipments provided that following conditions are met 1 Power cord Unshielded power cord must be used 2 Video inputs The input signal amplitude must not exceed the specified level CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Declar
4. must be used In USA Canada use a UL LISTED CSA LABELLED or CERTIFIED power cord set meeting the following specifications Rating min 125V 7A Length max 3 0 m Type SVT or SJT Plug type NEMA 5 15P figure Parallel blade Grounding type Failure to do so may cause fire or electric shock hazard mw USE ONLY THE CORRECT VOLTAGE POWER OUTLET WITH SAFETY GROUND CONNECTION 100 120 V for USA Canada etc 200 240 V for Europe etc This monitor will automatically adjust to the input voltage 100 240V B CAUTION for 200 240V operation only This equipment relies on the protective devices in the building installation for short circuit and over current protection Refer to the following table for the suitable number and location of the protective devices which should be provided in the building installation PROTECTIVE DEVICES IN SINGLE PHASE EQUIPMENT OR SUB ASSEMBLIES Protection Minimum number Location against of fuses or circuit breaker poles Equipment to be connected td Earth faults A Both conductors POWER SYSTEMS with earthed Over current Either of the two neutral reliably identified conductors Equipment to be connected to Earth faults Both conductors any supply including IT famis 2 Either of the two POWER SYSTEMS and conductors supplies with reversible plugs Verify that the protective devices in the building installation meets the conditions in the table prior to installing the equipment B
5. or business environment DO NOT subject the unit to vibrations dust or corrosive gases Q KEEP IN A WELL VENTILATED PLACE DO NOT cover this monitor or place anything against any sides not only the top right and left side but also the rear and bottom side of unit Ventilation holes are provided at all sides of the rear cover to prevent the temperature from rising mE KEEP AWAY FROM HEAT SOURCES AVOID placing the unit in direct sunshine or near a heating appliance B BE CAREFUL OF MAGNETIC FIELDS DO NOT place a magnet loudspeaker system floppy disk drive printer or anything which will generate magnetism near the unit A magnetic field may cause blurred colours or distortion of the displayed pattern B BE CAREFUL OF GENERATED MAGNETISM After the power has been turned on or DEGAUSS button has been pressed the CRT is demagnetised for approximately 10 seconds This generates a strong magnetic field around the front cover which may affect the data stored on magnetic tape or disks near the front cover Place such magnetic recording equipment and tapes disks away from this unit AMBIENT ILLUMINATION Avoid direct rays of the sun or room lighting onto the CRT screen in order to prevent eye fatigue m THE ENCLOSED POWER CORD MUST BE USED In Europe a proper European standard approved power cord is to be used with this monitor Fora rated current up to 6 A a type not lighter than HO5VV F 3G 0 75 mm or HO5VVH2 F 3G 0 75 mm
6. AND EUROPE FOR THE U K PLEASE REFER TO THE NOTES ON THIS PAGE IMPORTANT FOR UNITED KINGDOM WORDING FOR CLASS EQUIPMENT INSTRUCTION BOOKS AND LABELS The mains lead on this equipment is supplied with a moulded plug incorporating a fuse the value of which is indicated on the pin face of the plug Should the fuse need to be replaced an ASTA or BSI approved BS 1362 fuse must be used of the same rating If the fuse cover is detachable never use the plug with the cover omitted If a replacement fuse cover is required ensure it is of the same colour as that visible on the pin face of the plug Fuse covers are available from your dealer DO NOT cut off the mains plug from this equipment If the plug fitted is not suitable for the power points in your home or the cable is too short to reach a power point then obtain an appropriate safety approved extension lead or consult your dealer Should it be necessary to change the mains plugs this must be carried out by a competent person preferably a qualified electrician If there is no alternative to cutting off the mains plug ensure that you dispose of it immediately having first removed the fuse to avoid a possible shock hazard by inadvertent connection to the mains supply WARNING THIS EQUIPMENT MUST BE EARTHED IMPORTANT The wires in the mains lead are coloured in accordance with the following code Green amp Yellow to Earth Brown to Live Fuse Blue to Neutral Cord Clamp
7. BE CAREFUL OF POWER CORD CONNECTION Before inserting the plug of the power cord into a power point of the correct voltage check that the connection portion of the power cord is clean with no dust Then insert the plug of power cord to a power point firmly otherwise it may cause electrical shock or fire E REMOVE THE POWER CORD FOR COMPLETE SEPARATION For complete separation from the power source remove the power cord from the monitor or from the wall outlet B AVOID FREQUENT POWER ON OFF SWITCHING DO NOT repeat OFF and ON in a short period lt may cause blurred colours or distortion of the displayed pattern B BE CAREFUL OF STATIC ELECTRICITY ON CRT SURFACE To prevent electrical shock by the static electricity on the CRT surface disconnect the power cord at least 30 seconds after turning off the power B ABOUT CLEANING This monitor has a non glare and anti electrostatic treatment on the surface of the screen Use water or alcoholic solvent with soft cloth like gauze to clean the surface of the screen NEVER use abrasive glass cleaner containing highly concentrated ammonia and strong base chemicals since they damage the surface treatment Clean the cabinet and controls with a lightly moistened soft cloth DO NOT use aerosol sprays solvents or abrasive cleaners mim E FCC Federal Communications Commission STATEMENT WARNING WARNING This equipment has been tested and found to comply with the limits for a Class
8. HITACHI USER MANUAL COLOUR MONITOR MANUEL D UTILISATION CM650ET BEDIENUNGSANLEITUNG MANUAL DE USUARIO MANUALE DI ISTRUZIONI with EasyMenu EasyMenu is HITACHI s On Screen Display function for easy operation READ THE INSTRUCTIONS INSIDE CAREFULLY KEEP THIS USER MANUAL FOR FUTURE REFERENCE For future reference record the serial number of your colour monitor SERIAL No The serial number is located on the rear of the monitor This monitor is ENERGY STAR compliant when used with a computer equipped with VESA DPMS The ENERGY STAR emblem does not represent EPA endorsement of any product or service ah 100 As an ENERGY STAR Partner Hitachi Ltd has determined that this us LAY A product meets the ENERGY STAR guidelines for energy efficiency RO amp NOTE The information in this manual is subject to change without notice The manufacturer assumes no responsibility for any errors that may appear in this manual TRADEMARK ACKNOWLEDGEMENT VGA is a registered trademark of International Business Machines Corporation VESA is a trademark of a nonprofit organisation Video Electronics Standard Association ENERGY STAR is a trademark of Environmental Protection Agency EPA REMARQUE Les informations contenues dans ce manuel peuvent tre modifiees sans preavis Le constructeur n accepte aucune responsabilitb pour les erreurs qui peuvent eventuellement apparaitre dans ce manuel MARQUES D POS ES VGA es
9. Standard colour balance 9300K 6500K Standard colour balance 6500K USER User defined 30 minutes to reach optimum performance level AC 100 240 V automatically selected 50 60 Hz 2 5 A max Power Consumption 110 W typical provided with power save circuit 412 W X 431 H x 373 D mm including Tilt amp Swivel Base 17 0 kg approx including Tilt amp Swivel Base Operation Storaoe Temperature 5 C to 40 C 20 C to 60 C Humidity 10 to 80 10 to 90 USB HUB Module with 4 downstream and 1 upstream ports Specification and Design are subject to change without notice 1 12
10. ation of Conformity According to 47CFR Part 2 and 15 for Class B Personal Computers and Peripherals and or CPU Boards and Power Supplies used with Class B Personal Computers We Nissei Sanqyo America Ltd Located at 200 Lowder Brook Drive Suite 2200 Westwood MA 02090 1124 U S A Declare under sole responsibility that the product identified herein complies with 47CFR Part 2 and 15 of the FCC rules as a Class B digital device Each product marketed is identical to the representative unit tested and found to be compliant with the standards Records maintained continue to reflect the equipment being produced can be expected to be within the variation accepted due to quantity production and testing on a statistical basis as required by 47CFR 2 909 Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation The above named party is responsible for ensuring that the equipment complies with the standards of 47CFR 15 101 to 15 109 Tradename Color Monitor With USB HUB Model Number CM650 With DUB 01 she Signature of Party Responsible v pm Printed name of Party Responsible Satoshi Tanabe Executed on Date at Place November 24 1998 MA U s A BM FOR THE CUSTOMERS IN THE U K THIS PRODUCT IS SUPPLIED WITH A TWO PIN MAINS PLUG FOR USE IN MAINL
11. en the PC is not in use This power management System is effective only when used with VESA DPMS compliant PC or Video Card APM State Signal Requirement Monitor Action Power Consumption Power LED Siendoy H Sync OFF Switches to Suspend V Syne OFF saving mode amp H Sync OFF and screen darkens 3W max Orange V Sync OFF NOTE Once the monitor receives the first signal from the PC and initiate the power management system This monitor complies with VESA DDC 1 2B specifications Plug amp Play is a system with computer peripherals including monitors and operating system It works when the monitor is connected to DDC ready computer that is running an operating system software that is capable for the plug amp play CRT input Signal Synchronisation Resolution Video Clock frequency Viewable Image Size Viewable Image Area Colour Temperature Warm up Time Power Supply Dimensions Weight Environmental Condition USB HUB optional 17 inch picture tube 0 22 mm horizontal dot pitch 0 21 mm horizontal mask pitch 100 deflection FS double focus AR ASC coating Video Sync 0 7 Vp p analogue Separate H V TTL level Composite H V TTL level Horizontal 31 69 kHz Vertical 50 130 Hz Horizontal 1280 dots max Vertical 1024 lines max 110 MHz typical 16 0 inches 406 mm diagonal typical Horizontal 326 mm typical Vertical 245 mm typical 9300K
12. ental demands for example in respect of the reduction of electric and magnetic fields physical and visual ergonomics and good usability Below you will find a brief summary of the environmental requirements met by this product The complete environmental criteria document may be ordered from TCO Development SE 114 94 Stockholm Sweden Fax 46 8 782 92 07 Email Internet development tco se Current information regarding TCO 99 approved and labelled products may also be obtained via the Internet using the address http www tco info com Environmental requirements Flame retardants Flame retardants are present in printed circuit boards cables wires casings and housings Their purpose is to prevent or at least to delay the spread of fire Up to 30 of the plastic in a computer casing can consist of flame retardant substances Most flame retardants contain bromine or chloride and those flame retardants are chemically related to another group of environmental toxins PCBs Both the flame retardants containing bromine or chloride and the PCBs are suspected of giving rise to severe health effects including reproductive damage in fish eating birds and mammals due to the bio accumulative processes Flame retardants have been found in human blood and researchers fear that disturbances in foetus development may occur The relevant TCO 99 demand requires that plastic components weighing more than 25 grams must not contain flame retarda
13. hanges the colour to the changes the colour to the oe previous mode next mode 9300K 6500K USER makes the Red stronger When the Red reaches the When the Green or Blue upper limit it makes the reaches the upper limit it Green and Blue weaker make the Red weaker makes the Blue and Red makes the Green stronger stronger When the Green reaches When the Blue or Red th upper limit it makes the reaches the upper limit it Blue and Red weaker make the Green weaker makes the Red and Green makes the Blue stronger stronger When the Blue reaches the When the Red or Green upper limit it makes the reaches the upper limit it Red and Green weaker make the Blue weaker La i i Table l SEORUIR HOS Fue a B H MOIRE makes the operation of makes the operation of horizontal moire circuit horizontal moire circuit weaker stronger g VMOIRE makes the operation of makes the operation ol vertical moire circuit weaker vertical moire circuit stronger Sy A LANGUAGE SELECT POWER MANAGEMENT AUTO SAVE DEGAUSS changes the EasyMenu changes the EasyMenu language to the previous language to the next mode mode FRANCAIS French ENGLISH l ITALIANO Italian DEUTSCH German 1 l ESPANOL Spanish ESPANOL Spanish 1 l DEUTSCH German ITALIANO Italian l ENGLISH FRAN AIS French disables OFF the Power enables ON the Power Saving System Saving Systems Refer
14. ive waste it is vital to save energy Electronics equipment in offices is often left running continuously and thereby consumes a lot of energy What does labelling involve This product meets the requirements for the TCO 99 scheme which provides for international and environmental labelling of personal computers The labelling scheme was developed as a joint effort by the TCO The Swedish Confederation of Professional Employees Svenska Naturskyddsforeningen The Swedish Society for Nature Conservation and Statens Energimyndighet The Swedish National Energy Administration Approval requirements cover a wide range of issues environment ergonomics usability emission of electric and magnetic fields energy consumption and electrical and fire safety The environmental demands impose restrictions on the presence and use of heavy metals brominated and chlorinated flame retardants CFCs freons and chlorinated solvents among other things The product must be prepared for recycling and the manufacturer is obliged to have an environmental policy which must be adhered to in each country where the company implements its operational policy The energy requirements include a demand that the computer and or display after a certain period of inactivity shall reduce its power consumption to a lower level in one or more stages The length of time to reactivate the computer shall be reasonable for the user Labelled products must meet strict environm
15. lity and secure the screws on the connector shell firmly 5 DDCGround 6 RedGround J 8i NEC ER i 1 1 1 D Sub Mini 1 B pin Connector 4 Power On Turn on the Power Switch of the monitor first then the computer Refer to Page 1 8 POWER ON OFF the standard settings The following industrial standard settings have been pre programmed by the factory No Video Mode Name Horizontal Video Mode __ with Resolution and Vertical Frequency Frequency VGA 640 x 400 70 Hz 31 47 kHz VGA VESA 640 x 400 85 Hz 37 86 kHz VESA Microprocessor based preset functions can store 26 sets of geometry settings including a n 2 3 VESA 4 VESA 1024 x 768 75 Hz VESA VESA 6 VESA 1152 x 864 75 Hz 6750kHz VESA NOTE E Input signals with approximately the same frequencies may be regarded as the same signal W The following horizontal timing conditions are recommended at sync H V separate or H V composite for 31 kHz 45 kHz horizontal frequency Horizontal front porch should be more than 0 1 ps Horizontal sync width should be within 1 0 3 8 ps Horizontal back porch should be more than 1 2 ps Horizontal blanking width should be more than 3 5 ps for 45 kHz 69 kHz horizontal frequency Horizontal front porch should be more than 0 1 us Horizontal sync width should be within 1 O 3 0 us Horizontal back porch should be more than 1 1ps Horizo
16. ntal blanking width should be more than 3 0 ps W The following vertical timing conditions are recommended Vertical front porch should be more than 10 us Vertical sync width should be less than 200 us Vertical back porch should be more than 400 ps Vertical blanking width should be more than 500 ps E In case the front or back porch is extremely long or the data display time is extremely short it may not be able to set the expected size and position W Standard settings are subject to change without notice Adjust Function Switches Switches Status Switch Power LED Power Switch POWER ON OFF Press the Power switch to switch the power ON or OFF W When power is ON the power LED lights W After turning OFF the switch wait at least 5 seconds before restarting the monitor Otherwise the monitor may operate incorrectly W ifthe picture doesn t appear turn OFF the power switch make sure of the following and wait at least 30 seconds before restarting the monitor Make sure the power switch of the computer power cord connection signal cable connection and the input sync signal are correct CONTROL D Press the Status switch The On Screen Display function of EasyMenu then shows the selected function its condition the function menu and the input signal frequencies W You can select the EasyMenu language Use the function LANGUAGE SELECT To select the function use the Function switches
17. nts with organically bound bromine or chlorine Flame retardants are allowed in the printed circuit boards since no substitutes are available Cadmium Cadmium is present in rechargeable batteries and in the colour generating layers of certain computer displays Cadmium damages the nervous system and is toxic in high doses The relevant TCO 99 requirement states that batteries the colour generating layers of display screens and the electrical or electronics components must not contain any cadmium Mercury Mercury is sometimes found in batteries relays and switches It damages the nervous system and is toxic in high doses The relevant TCO 99 requirement states that batteries may not contain any mercury It also demands that mercury is not present in any of the electrical or electronics components associated with the labelled unit CFCs freons The relevant TCO 99 requirement states that neither CFCs nor HCFCs may be used during the manufacture and assembly of the product CFCs freons are sometimes used for washing printed circuit boards CFCs break down ozone and thereby damage the ozone layer in the stratosphere causing increased reception on earth of ultraviolet light with e g increased risks of skin cancer malignant melanoma as a consequence Lead Lead can be found in picture tubes display screens solders and capacitors Lead damages the nervous system and in higher doses causes lead poisoning The relevant TC0 99 req
18. regisrato da International Business Machine Corporation VESA e il marchio di riconoscimento della organizzazione a non profitto Video Electronics Standard Association ENERGY STAR e il marchio di fabbrica della Eviromental Protection Agency EPA Congratulations You have just purchased a TCO 99 approved and labelled product Your choice has provided you with a product developed for professional use Your purchase has also contributed to reducing the burden on the environment and also to the further development of environmentally adapted electronics products Why do we have environmentally labelled computers In many countries environmental labelling has become an established method for encouraging the adaptation of goods and services to the environment The main problem as far as computers and other electronics equipment are concerned is that environmentally harmful substances are used both in the products and during their manufacture Since it is not so far possible to satisfactorily recycle the majority of electronics equipment most of these potentially damaging substances sooner or later enter nature There are also other characteristics of a computer such as energy consumption levels that are important from the viewpoints of both the work internal and natural external environments Since all methods of electricity generation have a negative effect on the environment e g acidic and climate influencing emissions radioact
19. t functions can store 26 sets of geometry settings including the standard factory settings Digital Colour Control Function Red green and blue colour balance is adjustable by digital control An adjusted colour setting can be stored and recalled by the colour select button Moire Reduction This monitor has horizontal and vertical moire reduction function Power Saving System The Environmental Protection Agency EPA has established a voluntary program by which manufacturers enable computer products to go into low power states while not being used This monitor has a low power sleep mode which is compliant with the EPA requirements for the ENERGY STAR program and will assist you in conserving energy Please refer to the section of POWER SAVING SYSTEM for details EasyMenu x An On Screen Display function that allows direct access to MN adjust all operations from the front panel PLUG amp PLAY This monitor is VESA DDC1 2B compliant when used with a computer compliant with VESA DDC Display Data Channel m NEVER REMOVE THE REAR COVER The rear cover MUST be removed only by authorised service personnel This colour monitor contains high voltage components as M THE POWER POINT SHOULD BE CLOSE TO THE MONITOR AND EASILY ACCESSIBLE BW INSTALL THE UNIT IN AN SUITABLE ENVIRONMENT DO NOT expose this monitor to rain or moisture to prevent electric shock or fire hazard This unit is designed to be used in an office
20. t une marque d pos e d International Business Machines Corporation VESA est la marque d une organisation sans but lucratif la Video Electronics Standard Association ENERGY STAR est une marque de I EPA Environmental Protection Agency USA HINWEIS Anderungen der Daten in dieser Bedienungsanleitung sind vorbehalten Der Hersteller bernimmt keine Haftung f r jegliche in diesem Handbuch eventuell enthaltenen Irrt mer GESCH TZTE WARENZEICHEN VGA ist ein eingetragenes Warenzeichen der International Business Machines Corporation VESA ist ein Warenzeichen der Video Electronics Standard Association einer Organisation ohne Erwerbscharakter ENERGY STAR ist ein Warenzeichen der Environmental Protection Agency EPA NOTA La informaci n contenida en este manual est sujeta a cambios sin previo aviso El fabricante no se responsabiliza de los errores que puedan aparecer en este manual RECONOCIMIENTO DE MARCAS VGA es una marca registrada de International Business Machines Corporation VESA es una marca registrada de una organizaci n sin nimo de lucro Video Electronics Standard Association ENERGY STAR es una marca de Environmental Protection Agency EPA NOTA Tutte le informazioni di questo manuale sono soggette ad essere modificate senza preavviso Il costruttore non si assume responsabilita per errori che possono essere riportati sul manuale Marchi di fabbrica riconosciuti VGA e um marchio di fabbrica
21. to Page l l 1 Refer to Page l l 1 POWER MANAGEMENT POWER MANAGEMENT SYSTEM SYSTEM disables OFF the Autg enables ON the Auto Save function Save function Refer to Page l 8 Refer to Page l 8 SAVE SAVE degauss Use this function only when you see colour impurities on the screen after turning ON the monitor Wait for about 10 minutes before repeating the function Remember the monitor is automatically degaussed during initial power on quits the functions of EasyMenu When the monitor has detected the change of the signal input condition the monitor will indicate the condition automatically as follows The monitor detects The EasyMenu indicates proper signal the horizontal frequency and vertical frequency Precision frequency Horizontal 2kHz approx Vertical 2Hz approx The monitor detects no The EasyMenu indicates sync signal the message NO SYNC SIGNAL The EasyMenu indicates the message INVALID SCAN FREQ The Power LED lights orange The monitor detects a sync signal which is out of specification or unstable The monitor is in OFF mode Refer to POWER MANAGEMENT SYSTEM below This monitor meets the ENERGY SrAR VESA DPMS Display Power Management Signalling standard specifications The monitor has a built in power management system that automatically reduces power consumption wh
22. uirement permits the inclusion of lead since no replacement has yet been developed Bio accumulative is defined as substances which accumulate within living organisms Lead Cadmium and Mercury are heavy metals which are Bio accumulative 491T551 FEATURES ww arate ieee ae l 1 CAUTIONS choke test eet tet e dete ete pe ete Fer tte ete ere ta enda 1 2 INSTALLATION 5 reete ret te eee ne nnt Re eee nta Rene Rena rk l 6 mm STANDARD SETTINGS kiniinin nete te ted dera 1 7 OPERATION 5 3 nete he ote else ce e set ial teat clit dms l 8 AUTOMATIC SIGNAL CHECK ssssssssessseseseeeneennenner enne 1 11 POWER MANAGEMENT SYSTEM essent 1 11 PLUG amp PLAY tette tette he eere ek nt a ehe nc erede ce eere ee 1 11 SPEGIFIGATIONS 2 ita attt tta terat ttti ia tea hive i e ie d dada 1 12 The following features are provided by the Colour Monitor Sharpest Focus and Highest Contrast Flat screen Enhanced Dot Pitch EDP CRT with FS double focus and AR ASC coating gives the sharpest focus and highest contrast to minimise eye fatigue Wide range Multi Scanning Automatic scanning and automatic adjustment to conform with a wide range of scanning frequencies and user requirements Digital Picture Control Function Position size pincushion trapezoid parallelogram pin balance and rotation are adjustable by digital controls Geometry setting can be stored for different H V frequencies Microprocessor based prese