1. VALUETEAM 3060 80 IMAGETEAM 3220 Disclaimer Hand Held Products Inc d b a HHP HHP reserves the right to make changes in specifications and other information contained in this document without prior notice and the reader should in all cases consult HHP to determine whether any such changes have been made The information in this publication does not represent a commitment on the part of HHP HHP shall not be liable for technical or editorial errors or commissions contained herein not for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HHP 2001 2002 Hand Held Products Inc All rights reserved Web address www hhp com Statement of Agency Compliance This device complies with part 15 of the FCC Rules Operation 1s subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Class A Compliance Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designe
2. 2 digits identified position max 3 insertion characters 1 3 characters to insert Tai a FIN Hex value for each isi 2 digits character FIN 2 digits identified position max 3 insertion characters 1 3 characters to insert 3rd Insertion Disable 9 FIN Hex value for each Enable 2 digits character FIN 2 digits identified position max 3 insertion characters 1 3 characters to insert Ath Insertion Disable 9 FIN Hex value for each Enable 2 digits character FIN 2 digits identified position max 3 insertion characters 1 3 characters to insert FACTORY DEFAULT The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computer or terminal It allows you to select desired bar code symbologies for formatter control and provides Multiple Position Insertion and Multiple Character Insertion max three characters in the identified position f the Data Formatter is enabled it arranges only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbolology ID or Record Suffix All of the above programmable parameters perform the same function depending on your setting Please refer to page 3 37 for information about the Bar Code Selection and Position Calculation of the data formatter To determine the hex value for the Character refer to the HEX ASCII Table on page A 6 Refer to page 3 12 for for the 2 digit symbology opt
3. Code 2 of 5 Family amp German Post Code Setting PROGRAM END Exit Family Code Selection Parameter Selection Option Code Code 2 of 5 Settings Select any Code 2 of 5 0 Select Standard Industrial 2 of 5 only 1 Select Matrix 2 of 5 only 2 Select Interleaved 2 of 5 only 3 Select Interleaved 2 of 5 S Code only 4 Select IATA only 5 Select China Postal Code only 6 7 Disable check digit verification Disable check digit transmission Enable check digit transmission Code 2 of 5 Min Length Default 06 Minimum length 2 digits Scan 2 digits from the option code chart in the Appendix Code 2 of 5 Max Length Default 99 9 Maximum length 2 digits 00 gt oO Scan 2 digits from the option code chart in the Appendix German Postal Setting Disable Enable FACTORY DEFAULT The scanner can decode almost all Code 2 of 5 symbologies automatically However since the Code 2 of 5 encoding algorithm is not very robust we recommend that you select only one kind of Code 2 of 5 for reading or set limited maximum and minimum reading lengths for reading 3 17 PROGRAM Family Code Selection Code 11 Settings Code 11 Min Length Code 11 Max Length Code 93 Settings Code 93 Min Length Code 93 Max Length FACTORY DEFAULT Programming the Scanner Symbology Programming Code 11 amp Code 93 Setting 4 Parameter Selection Select 1 check digit verification S
4. option codes 2nd Scan One or Several Option Codes Finish cycling selection If necessary Yes Repeat Want to select another Selection programming family No Exit programming mode 3 8 EXAMPLE 2 Scan PROGRAM Scan One of Family Codes Enter programming mode Select one of desired programming families Select several option codes of desired parameters 1 Select one or several option codes 2 If it s necessary scan FIN to terminate option code selection Want to select another programming family Exit programming mode Programming the Scanner MNI Host Interface Selection __ III TERMINAL ID gt PROGRAM END Exit Family Code Selection Parameter Selection Option Code Host Interface Selection Standard TTL RS 232 serial interface IBM PC XT 286 XT keyboard wedge interface Full Size Din IBM PS 2 25 30 series keyboard wedge interface Mini Din US EUROPEAN VERSION IBM PC AT PS 1 PS VP series keyboard wedge interface Mini Din PC AT PS 2 keyboard replacement interface without external keyboard General Notebook PC keyboard wedge interface PC AT PS 2 Compatibles General Notebook PC keyboard direct link interface without external keyboard APPLE ADB keyboard wedge interface Standard TTL RS 232 serial wedge interface Wand emulation interface USB keyboard interface for Microsoft Windows 98 2000 and Apple iMac Host Interf
5. Code 128 EAN 128 Max Length Default 99 4 Maximum length Scan 2 digits from the option code chart in the Appendix FACTORY DEFAULT Enable 1 check digit transmission 3 19 END Exit Option Code 2 digits 2 digits 2 digits 2 digits Programming the Scanner INIIIII Symbology Programming III UK Plessey amp Telepen Setting 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code UK Plessey Settings Select UK Plessey Standard Format Select UK Plessey CLSI Format Disable Convert X to A F 8 Disable check digit transmission Enable check digit transmission UK Plessey Min Length Default 04 Minimum length 2 digits Scan 2 digits from the option code chart in the Appendix UK Plessey Max Length Default 99 9 Maximum length 2 digits a Scan 2 digits from the option code chart in the Appendix Telepen Settings Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min Length Default 04 Minimum length 2 digits Scan 2 digits from the option code chart in the Appendix Telepen Max Length Default 99 Maximum length 2 digits Scan 2 digits from the option code chart in the Appendix FACTORY DEFAULT 3 20 PROGRAM Family Code Selection Keyboard Layout The Universal Selection is only for PC AT PS VP PS 2
6. or non acknowledgment from the host computer 3 25 Programming the Scanner MMI _andEmutationcontrei__ Output Polaritv Sianal State Marain Module Time PROGRAM Narrow Wide Ratio Code 39 Emulation END Exit Family Code Selection Parameter Selection Option Code Output Polarity High level 5Vdc on Bar low level on Space Determine the output voltage level for both bar and space Initial Signal State High Level 5Vdc Low level OVdc on Bar high level on Space EE Low Level 0Vdc Determine the initial state of output voltage level Margin Time 10 mseconds 30 mseconds 15 mseconds 50 mseconds 20 mseconds 4 100 mseconds 25 mseconds Delay time before data transmission Module Time Extremely short Long Short Medium Time base of minimum narrow bar Narrow Wide Ratio Code 39 Emulation Disable standard Code 39 emulation Enable standard Code 39 skip emulation Enable standard Code 39 replace emulation FACTORY DEFAULT Code 39 Skip When this option is selected all scanned data will be translated as Standard Code 39 wand emulation output If any lowercase characters are read they will be translated to upper case characters Any other characters that are not available in Code 39 symbology set will be skipped O 6 gt ne Ne O N gt O E Code 39 Replace Any character not normally available in the standard Code 39 symbology set will be translated as
7. IT3220 the user must have a serial adapter cable and a power supply Please refer to Chapter 3 Programming the Scanner to understand all details of HHP SET You will find HHP SET has totally changed the traditional ways of managing your bar code reading device Getting Started Terminal Interfaces 2 Terminal Interfaces The 113220 and VT3060B 3080B configured to work with a variety of interfaces by installing the scanners are easily desired cable adapter and by programming the selected After interface you will use and obtaining the suitable interface adapter cable plug the RJ45 Phone Plug of the IT3220 or VT3060B 3080B main cable into the connector of the selected interface cable adapter Please make sure the connector clicks terminal interface identifying the communication into place securely 3220 Main Cable Interface Cable Adapter All scanners have been preset to the IBM PC AT PS 2 Keyboard Wedge interface If you need to change the host interface please refer to the Host Interface Selection described in Chapter 3 to find your desired interface The following paragraphs provide the installation of the most popular host interfaces 2 1 Keyboard Wedge Interface The keyboard wedge interface allows data transmission from the scanner to the host through the existing keyboard port as traditional keyboard input PC AT PS 2 Keyboard Wedge For the keyboard we
8. If there is a 5 character input data string refer to the following to calculate the actual position for insertion xx 02 03 x 04 x x 00 01 05 Data Verifier Data Replacer Data Organizer If there is an 11 character data string please refer to the following to calculate the actual position for identification 2 ee ee 00 01 02 03 04 05 06 07 08 09 10 Application Example The bar code label is an all numeric 16 digit Interleaved 2 of 5 which includes the information of 6 digit date code 6 digit serial number and 4 digit unit price in that order The data code always starts with a 9 If a scanned bar code meets the above criteria the data will be separated into three fields Each field should end with a TAB The first digit of the date code which is a 9 should be replaced with an A The serial number should start with SN The first 2 digits of the unit price should be skipped Actual Bar Code read 9 8 10 2 5 1 2 3 4 5 6 9 8 7 6 Desired Output A81025 TAB SN123456 TAB 76 TAB Programming Procedure Important Notice Please note that the Condensed Data Editor will follow the preset working flow as below Verifier Formatter lt lt Replacer Organizer Consequently when you set the identified position in the Data Organizer you must consider the inserted data that you have already set via the Data Formatter Programming the Scanner Data Verif
9. RS 232 Peer to Peer Interface 9P D Sub Femal Connector Embedded Power Jack Illustration Appendix A Description RS 232 Serial Wedge Cable Converter 25P D Sub M amp F Connectors Embedded Power Jack Notebook PS 2 Keyboard Direct Link Cable Converter 6P Mini DIN Male Connector Wand Emulation Interface Cable Converter 9P D Sub Female Connector A 3 Appendix Beeping Indications Descriptions Beeping Buzzer Tone No Internal or operation memory error Repeated beeps Beginning the normal operation 2 short beeps high low 7 06 Completing to store the parameters shontbeeps low medumnigi 7777777777 08 Completing the master default and group deraut 3 shot beeps low hightiow 09 Completing the system information listing 3 short beeps medium high medium 1 Scanning FIN to finish programming selection A 4 Appendix A Keyboard Function Code Table No ANSI ASCII Key Function No ANSI ASCII Key Function oo Nu oo RESERVED J DIE OH ros ack o ese f SYN INS Imsom o o o fer ee om rr fef er om et oa BS Numeric Pad CAN 18H HOME asl en feno To emulate the key functions above program the scanner by using the corresponding ASCII hex value For example if you want to program in a suffix of a TAB you would follow the directions for programming a suffix on page 3 22 For option code scan 09 fo
10. THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT IN NO EVENT SHALL HHP BE LIABLE FOR INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES AND IN NO EVENT SHALL ANY LIABILITY OF HHP ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT WARRANTY TORT OR OTHERWISE EXCEED THE ACTUAL Limited Warranty AMOUNT PAID TO HHP FOR THE PRODUCT THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HHP MAY HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES LOSSES OR DAMAGES SOME STATES PROVINCES OR COUNTRIES DO NOT ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU All provisions of this Limited Warranty are separate and severable which means that if any provision is held invalid and unenforceable such determination shall not affect the validity of enforceability of the other provisions hereof Limited Warranty Duration The Limited Warranty duration for the T3220 is 2 years The Limited Warranty duration for the VT3060 80 is 1 year 5 2 Appendix A Appendix A Interface Cable Converters This chapter gives the most up to date description of scanner The following provides information about the most popular accessories including various Host Interface Cable Adapters cable adapters including Beeping Indications and the Keyboard Function Code Table PC AT
11. again If there is no scanning operation performed during the pre defined auto power off time the scanner enters the idle state after the pre defined auto power off duration 3 27 Alternative Mode When this operation mode is selected the scanner keeps the light source of the scanner turned on and disables the infrared sensor before the pre defined auto power off duration Because you do not have to press the trigger frequently it is very convenient for multiple scanning After each good read the auto power off timer counter is reset After the scanner turns off the light source you must press the trigger to turn on the light source again If there is no scanning operation in pre defined auto power off duration the scanner turns off the light source and enables the infrared sensor after the pre defined auto power off duration Presentation Mode When this operation mode is selected the scanner flashes the light source of the scanner without using the trigger If the scanner detects an image similar to a bar code the scanner forces on the light source automatically and scans If the scanner cannot detect a bar code it resets the light source immediately to blinking Adjusting the Pulse Driven Duty Cycle can change the frequency of the blinking Auto Trigger Mode Continued Power On When this operation mode is selected the light source of the scanner is forced on for continued operation without pressing the trigger switch This mod
12. and IBM compatibles in DOS or Windows environment that can perform unique output without Caps Lock on off Output Style concern All transmitted data will follow the original full ASCII form You also need not worry about the upper lower case control FACTORY DEFAULT Please refer to the HEX ASCII Table listed in Appendix A to determine HEX codes for characters symbols and functions to be used as premble or postamble Programming the Scanner Keyboard Interface Control Keyboard Layout Language Setting 4 Parameter Selection USA QWERTY France AZERTY Germany QWERTZ United Kingdom UK QWERTY Canadian French QWERTY Spain QWERTY Sweden Finland QWERTY Portugal QWERTY Norway QWERTY Latin America QWERTY Italy QWERTY Netherlands QWERTY Denmark QWERTY Belgium AZERTY Switzerland Germany QWERTY Iceland QWERTY Universal only available for IBM PC AT PS VP in MS DOS and Windows Mode END Exit Option Code To set preamble or postamble as function key output you must enable the Function Key Emulation feature as listed in page 3 23 first Keyboard Interface Message String Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix 1 15 characters 2 3 digits 1 or 2 characters variable length 1 or 2 characters 3 21 1 15 characters 1 character Programming the Scanner INIMIII _eyboardInterfacecontroi _ III Record Suffix Pr
13. contact the HHP Product Service Department at the address telephone number listed below to obtain a Return Material Authorization number RMA before returning the product Main Office HHP Service Department 7510 East Independence Boulevard Charlotte NC 28227 Product Service Department Telephone 800 782 4263 Fax 704 566 9904 For service in Europe please contact your HHP representative or your local distributor European Office Hand Held Products Inc Nijverheidsweg 9 5627 BT Eindhoven The Netherlands Telephone 31 0 40 29 01 600 Fax 31 40 242 5672 United Kingdom Office Hand Held Products Inc Dallam Court Dallam Lane Warrington Cheshire WA2 7LT United Kingdom Telephone Int 44 0 1 925 240055 Or Int 353 1 216 0070 Fax Int 44 0 1 925 631280 Or Int 353 1 295 6353 Customer Service For service in Asia please contact your HHP representative or your local distributor Asia Pacific Office Hand Held Products Inc 10 F Tung Sun Commercial Centre 194 200 Lockhart Road Wanchai Hong Kong Telephone Int 852 2511 3050 or 2511 3132 Fax Int 852 251 1355 For service in Japan please contact your HHP representative or your local distributor Japan Office Hand Held Products Inc Bon Marusan 8F 3 5 1 Kanda Jinbocho Chiyoda ku Toyko 101 Japan Telephone Int 81 3 5212 7392 Fax Int 8 1 3 3261 7372 4 2 For service in Latin America please contact your HHP representa
14. into USB keyboard interface mode The scanner is now ready to use Programming the Scanner 3 Programming the Scanner There are two ways to configure the T3220 or the VT3060 3080 either using HHP SET or the programming bar codes in this user s guide Via HHP SET HHP SET is a unique software utility designed to operate under Microsoft Windows 95 98 NT or above HHP SET offers a convenient and user friendly way to program the scanner Via Bar Code Programming Menu The bar code programming menu is designed for field programming convenience Before you use the bar code programming menu please take the time to review the command structure and various programming procedures HHP SET The innovative HHP SET utility provides the following features User Friendly On screen Configuration Configuration Download and Upload Program Firmware Field Upgrade Flash 3 1 Check Software Revision Full featured Data Editor These outstanding software design beneficial features memory ASIC HHP SET at a Glance ES Geena Cimrmani Peegeedic bam L LA B D Spa i Uppi Cosprccii SHHP 7 SET Copyright 7000 Kond Held Prodkecte AN right peered HHP HHP SET Main Screen _ Main Re Data Editor Screen are accomplished through and on board advanced flash SR e lei Ele Gomiguw Commenitaton a Gi Mew Frite Bite fi uee D cote gj seco Bp conin Bar Co
15. the 89 336 EEC Electromagnetic Compatibility Directive EN55022 1998 Class A For further information please contact Hand Held Products Inc Nijverheidsweg 9 5627 BT Eindhoven The Netherlands 1 Table of Contents Chapter 1 Getting Started About This Manual Chapter 2 Terminal Interfaces Keyboard Wedge Interface RS 232 Serial Interface USB Keyboard Interface Chapter 3 Programming the Scanner HHP SET Data Editor Bar Code Programming Menu Programming Procedures Host Interface Selection Symbology Programming Keyboard Interface Control Serial Interface Control Wand Emulation Control Operating Control Condensed Editor 1 1 3 9 3 11 3 21 3 24 3 26 3 27 3 32 111 Chapter 4 Customer Service Main Office United Kingdom Office Asia Pacific Office Japan Office Latin America Office Application Support Chapter 5 Limited Warranty Appendix A Interface Cable Converters Beeping Indications Keyboard Function Code Table ASCII Input Shortcut Bar Code Command Menu Sample Bar Codes Bar Code System Command A 1 A 4 A 6 A 7 A 8 A 9 1V Getting Started 1 Getting Started The IMAGETEAM 3220 Mid Range Linear Imager replaces traditional laser bar code scanners with a high speed scanner at a lower cost Equipped with a new generation light intensifier and optical design the IT3220 has a high intensity aiming line and captures bar codes from as far away as 8 inches 20 3 cm IT3220 exce
16. 2 Pinouts PIN 1 VCC 5V PIN 2 TD PIN 3 RD PIN 4 NC 0 PIN 5 GND oe PIN 6 NC 59 PIN 7 CTS PIN 8 RTS PIN 9 VCC 5V 9 Pin D sub RS 232 Female Connector PIN 2 RD PIN 3 TD PIN 4 CTS PIN 5 RTS PIN 6 NC PIN 7 GND PIN 16 VCC 5V PIN 25 VCC 5V o 26 25 Pin D sub RS 232 Female Connector Terminal Interfaces USB Keyboard Interface The USB interface is one of the common standard peripheral interfaces for today s computer system working under Windows 98 and Windows 2000 or above Scanning the following bar code will program for the USB USB Keyboard Interface interface Main Cable To Computer USB Port FHE gt USB Keyboard Interface Connection 2 4 Make sure your computer has a USB port and the operating system is Windows 98 Windows NT 5 0 and Windows 2000 or above Plug the RJ45 phone plug of the scanner main cable into the USB keyboard cable converter Plug the 4 pin USB Type A connector into the desired USB port of your computer You will hear the power on beep twice to signal that the power on routine of the scanner is completed Whenever the scanner s USB interface scanner is connected to any computer system for the first time a string of USB Manufacturer ID messages will display to register the scanner into the operating system Please scan the USB Keyboard Interface bar code to configure the scanner
17. Code Option Code Symbol ID 1 character Code 128 default B Scan hex value 2 digits UCC EAN 128 default C default C Scan hex value 2 digits UPC A default A Scan hex value 2 digits EAN JAN CAN 13 default F Scan hex value 2 digits Codabar NW 7 default D Scan hex value 2 digits Code 39 Code 32 default G Scan hex value 2 digits Code 93 default H Scan hex value 2 digits Standard Industrial 2 of 5 default 1 Scan hex value 2 digits Interleaved 2 of 5 default J Scan hex value 2 digits Matrix 2 of 5 default K Scan hex value 2 digits China Postal Code default L Scan hex value 2 digits German Postal Code default M Scan hex value 2 digits IATA default O Scan hex value 2 digits Code 11 default P Scan hex value 2 digits MSI Plessey default R Scan hex value 2 digits UK Plessey default S Scan hex value 2 digits Telepen default T Scan hex value 2 digits Symbol ID 2 character UPC E default E0 Scan hex value 2 or 4 digits FIN EAN 8 default FF Scan hex value 2 or 4 digits FIN To determine the hex value for the Character refer to the HEX ASCII Table found on page A 6 3 11 PROGRAM Family Code Selection Code ID Transmission Symbology Enable Remember to scan FIN to terminate this selection But if you select the Automatic discrimination scanner will terminate this selection automatically FACTO
18. Data Editor Data Editor is an Artificial Intelligence based expert system used to format the scanned data before it is transmitted to the host system The Data Editor condensed version has been embedded in the scanner You gain access to desired Data Editor s functions via scanning the menu s bar code The full feature Data Editor is only available through HHP SET which gives you the freedom of modifying the scanned data anyway you like and allows you to integrate the scanner into any existing application Data Format Editor The ultra powerful data editing functions provided by the Data Editor Through independent rules can easily get the following are controlled by user defined rules users functionality 3 3 General Transmission Control The available parameters include Preamble Postamble Suffix Symbol ID and Data Length Transmission and Transmission Time Control Advanced Data Verification The user can base the specific data format on the desired Bar Code Symbologies to select Valid ASCII Domain Valid Data Length Domain and Matched Data Value to establish any desired filtering algorithm This feature not only provides an on scanner data filter without application software modification but also reduces the error reading rate and improves data capture reliability Field Oriented Data Formatter The Field Oriented Data Formatter allows the user to flexibly divi
19. Keyboard Wedge Cable Converter Also all necessary bar code commands are printed in the foldout of the back cover of this manual PS 2 Keyboard Wedge Cable Converter General Notebook PC PS 2 Direct Link Cable Converter USB Type A Direct Link Cable Converter APPLE ADB Keyboard Wedge Cable Converter IBM ThinkPad Keyboard Wedge Cable Converter IBM ThinkPad Direct Link Cable Converter NEC 98xx Keyboard Wedge Cable Converter RS 232 Serial Interface Cable Converter RS 232 Serial Wedge Cable Converter Wand Emulation Interface Cable Converter Illustration Appendix A Description Illustration PC AT KB Wedge Cable Converter Desktop PC AT KB Wedge 5P DIN Male amp Female Connectors PS 2 KB Wedge Cable Converter PS 2 KB Wedge DOS V KB Wedge 6P Mini DIN M amp F Connectors USB KB Cable Converter USB KB Direct Link 4P USB Type A Male Connector Apple ADB Keyboard Wedge Cable Converter 4P Mini DIN M amp F Connectors Apple PowerMac ADB Keyboard Wedge Cable Converter 4P Mini DIN M amp F Connectors A 2 Description NEC 98xx Keyboard Wedge Cable Converter 8P Mini DIN M amp F Connectors IBM ThinkPad Direct Link Cable Converter 6P Mini DIN Male Connector IBM ThinkPad Keyboard Wedge Cable Converter 6P Mini DIN M amp F Connectors RS 232 Serial Cable Converter RS 232 Peer to Peer Interface 25P D Sub Female Connector Embedded Power Jack RS 232 Serial Cable Converter
20. RY DEFAULT Programming the Scanner Symbology Programming Code ID Transmission and Symbology Enable 4 Parameter Selection Disable symbology ID transmission Enable prefix symbology ID transmission Enable suffix symbology ID transmission Enable both prefix and suffix symbology ID transmission Automatic discrimination Code 128 UCC EAN 128 UPC A UPC E EAN CAN JAN 13 EAN CAN JAN 8 Codabar NW 7 Code 39 Code 32 HIBC Code 2 of 5 Family IATA Code 93 Code 11 MSI Plessey UK Plessey Telepen END Exit Option Code f your application is reading known limited bar code symbologies you may increase the reading speed and decrease the reading error possibility by enabling those known symbologies only Furthermore to add the Symbology ID into the transmitted data is also helpful for applications to identify the specific symbology ID For example to enable UPC A and Code 39 only scan the following bar codes PROGRAM Symbology Enable 0 2 0 7 FIN and END To further ensure fast accurate readings you can complete more complex configurations via full feature the Data Editor To configure the full feature the Data Editor you must use the HHP SET a Windows 95 98 NT based software utility specially designed for the scanner 3 12 Programming the Scanner INN Symbotogy Programming Code 39 0006 32 Settings PROGRAM END Exit Family Code Selection Parame
21. SAL I F USSEUR Description IMAGER PS 2 KB WEDGE KIT TUT Description TCC I Vedel ember a au a A1210001 00000 _____ __L_______ Serial Number C 6 O N344 Made in Taiwan 2 N 6 O n344 I I I I I I I I I I I I I I I I I I Made in Taiwan I I I I I I I I I I I I I I I I I www hhp com N344 www hhp com Hand Held Products Inc C Product Label N344 Hand Held Products Prod uct La bel PIN 3220 12 0000 P N 3220 12 S N A1210001 S N A1210001 Complies with FCC Part 15 and Canadian ICES 003 Complies with FCC Part 15 and Canadian ICES 003 Emission requirements See User s Manual for details Emission requirements See User s Manual for details Getting Started The IT3220 and VT3060B 3080B models come with a main cable equipped with a RJ 45 phone plug which can provide multiple host interface connections when combined with a host adapter cable Please note that a separated cable adapter is needed to complete the cable connection for product installation HHP SET HHP SET is a unique software utility that has been designed to operate under Microsoft Windows 95 98 Windows NT and Windows 2000 and provides the following functions User friendly on screen configuration Configuration download and upload Program Firmware field upgrade Check software revision Full feature data editor To use the HHP SET with the
22. Space 3 26 Programming the Scanner Trigger Modes This section allows the user to select the trigger mode that 5 different from the Trigger Mode default The operations of each trigger mode are described as below Low Power Mode When this operation mode is selected the scanner goes into idle state after scanning the bar code You must press the trigger to wake up the scanner for operation While the scanner is in the idle state there is only maximum 500uA standby current for the entire reading device It is very helpful for mobile data collection and application which are concerned with power savings but please keep a minimum of 120 milliseconds debounce time to stabilize the power transition Manual Trigger Mode When this operation mode is selected you must press the trigger to turn on the light source of the scanner before scanning the bar code If you do not press the trigger the light source will be turned off immediately Please note that the scanner maintains standby current You can adjust the debounce time to obtain faster triggering reading Level Mode Auto Power Off When this operation mode is selected the scanner continues to turn on the light source of the scanner before a good read or pre defined auto power off duration If the scanner decodes a bar code successfully it turns off the light source immediately After the scanner turns off the light source you must press the trigger to turn on the light source
23. ace Selection DOS V keyboard wedge interface DOS V keyboard wedge interface direct connect NEC PC 98xx keyboard wedge interface JAPANESE VERSION IBM ThinkPad 950 keyboard direct link interface without external keyboard 4 FACTORY DEFAULT For Notebook computer user we suggest that the user try ID 10 first then ID 14 USB keyboard interface is only supported by Windows 98 Windows 2000 or above and Apple iMac system Supported by Japanese Version only All other interfaces are supported by both the US European and Japanese units 3 9 Programming the Scanner User Defined Code ID This section allows the user to define and program a Code ID that is different from the Code ID default To specify a one character Code ID scan in the 2 digit hex value for that character Then scan END The hex value can be determined by referring to the HEX ASCII Reference Table on page A 6 To specify a two character Code ID scan the 2 digit hex values for each of the desired characters Then scan END If you only want to assign a one character Code ID for UPC E or EAN 8 scan the two digit hex code for the desired character Then Scan FIN and END bar codes Note To transmit the Code ID you have to enable Code ID transmission on page 3 12 Programming the Scanner INNI SymbologyProgrammis IMI User Defined Code ID 4 PROGRAM END Exit Family Code Selection Parameter Selection Option
24. ain programming bar code types are referred to as System Command Family Code and Option Code With the exception of the Option Code bar codes which are found on the foldout section in the back of the book each programmable family is contained on one page and each page includes all of the bar codes needed to program the scanner Refer to the flow chart on page 3 8 for further clarification System Command The System Command is the highest level bar code command that directs the scanner to perform immediate operations such exiting as entering programming mode PROGRAM programming mode EXIT listing system information SYSLIST recovering to factory preset configurations M_DEFAULT and so on Please note that all system commands will take a few seconds to complete the operations The user must wait for the completion beeps before scanning another bar code 3 6 Family Code The Family Code is scanned to select the user desired programming family More than one hundred programming families have been provided to meet any specific requirements Option Code The Option Codes is a set of bar code commands represented by 0 9 A F and finishing selection FIN For most settings you must select at least one option code following the family code selection to set the desired parameter for the selected programming family Programming Procedures As you scan the bar code command to select the desired parameters t
25. ame bar code twice even after a very long duration Also note that this feature is not available if you have selected Low Power Mode Manual Trigger Mode Level Mode or Diagnostic Mode Scan Voting Scan Voting is the number of times the same bar code is decoded before it is transmitted This feature is useful when the bar codes being read are of poor quality It should also be noted that this feature is not available if you have selected Low Power Mode Manual Trigger Mode Level Mode or Diagnostic Mode Auto Power Off Duration The Auto Power Off Duration is a pre defined power off time out counter for Level Mode and Alternative Mode You can adjust this parameter to meet your own application requirement 3 30 Pulse Driven Duty The Pulse Driven Duty is designed to control the flashing frequency of the light source For example the 1 2 duty cycle means that the scanner turns on the light source at a time equal to 1 2 the duty cycle Generally speaking the higher scan rate will take the higher duty Programming the Scanner MMI peration Control iil Reread Delay Scan Voting PROGRAM END Exit Option Code Family Code Selection Parameter Selection Reread Delay Disable Long time out duration Immediate time out duration Force Verification Short time out duration 9 Medium time out duration Scan Voting None 4 times 1 time 5 times 2 times Auto Power Off Duration Short around 2 seconds oo
26. arty B excessive voltage or current supplied to or drawn from the interface connections C static electricity or electro static discharge D operation under conditions beyond the specified operating parameters or E repair or service of the product by anyone other than HHP or its authorized representatives This warranty shall extend from the time of shipment for the duration published by HHP for the product at the time of purchase Warranty Period Any defective product must be returned at purchaser s expense during the Warranty Period to HHP s factory or authorized service center for inspection No product will be accepted by HHP without a Return Materials Authorization which may be obtained by contacting HHP In the event that the product is returned to HHP or its authorized 1 service center within the Warranty Period and HHP determines to its satisfaction that the product is defective due to defects in materials or workmanship HHP at its sole option will either repair or replace the product without charge except for return shipping to HHP EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRANTIES EITHER EXPRESSED OR IMPLIED ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE HHP S RESPONSIBILITY AND PURCHASER S EXCLUSIVE REMEDY UNDER THIS WARRANTY IS LIMITED TO
27. d to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution Any changes or modifications made to this device that are not expressly approved by Hand Held Products Inc may void the user s authority to operate the equipment Note To maintain compliance with FCC Rules and Regulations cables connected to this device must be shielded cables in which the cable shield wire s have been grounded tied to the connector shell Canadian Notice This equipment does not exceed the Class A limits for radio noise emissions as described in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada 6 The CE mark the product indicates that the system has been tested to and conforms with the provisions noted within
28. de Screen Programming the Scanner While you are asking HHP SET to do the Download Upload and Diagnostic with the scanner HHP SET will ask you to use the scanner to scan the Host Link Command for initial handshaking with HHP SET and then perform your desired action HHP SET Host Link Software Installation You may download HHP SET from the IT3220 or VT3060B 3080B product pages from our web www hhp com site at On screen Configuration Compared with the traditional configurations done via bar code menus HHP SET provides a GUI interface that allows the user to easily configure the scanner The Save feature allows the configuration to be saved as a file The Convert feature consolidates all programmable parameters for a certain application and prints the configuration list 3 2 Configuration Download and Upload You can retrieve Upload the configurations from the scanner or send Download new configurations to the scanner Of course duplicating preset configurations is as easy as 1 2 3 Program Field Upgrade Internal program firmware change or modification is only one step away via the Field Upgrade feature of the utility Check Software Revision You can use the Check Revision feature to check the software revision number to verify if the communication between your scanner and host system is good and to check the operation of the beeper and the indicator light Programming the Scanner
29. de scanned data by Delimiter or Length When used with Added Field Sequence Arrangement features you can implement Insert Delete Replace Re organize and other data editing capabilities beyond your imagination and Transmission Programming the Scanner Application Example The bar code label is a 16 digit Code 39 that contains a 6 digit date code a 6 digit serial number and a 4 digit unit price in that order The scanner can do the following for you without software modification Check the bar code to see if it is Code 39 or not Reject any codes that are not Code 39 Check the bar code content to see if it is numeric or not Reject any codes that are not all numeric as invalid Check the first two digits to see if they match 99 Reject any codes that do not match Output each of the three fields followed by a TAB The date code output should skip 99 and replace it with AA The serial number output should be led with S N The first 2 digits 98 of unit price output should be skipped The output sequence should be unit price 76 date code 1025 and serial number 123456 Actual Bar Code label 9910251234569876 93910251 234569576 3 4 Desired Output 76 TAB AA1025 TAB S N 123456 TAB Please use HHP SET to configure the full feature Data Editor and follow the procedur
30. dge solution the scanner must work with the existing keyboard concurrently If you want to link the scanner to a computer keyboard port without a PC AT or PS 2 keyboard please select Emulate External Keyboard This selection instructs the scanner to perform the power on handshaking and routine reply between computer and keyboard Terminal Interfaces Keyboard Wedge Installation Turn off your computer system and unplug the keyboard Plug the RJ45 phone plug of scanner s main cable into the PC AT or PS 2 cable converter Plug the male connector of the cable converter into the keyboard port of your computer Plug the male connector of keyboard into the female connector of the cable converter Turn on your computer system Open a text program such as Notepad or Microsoft Word and scan a bar code sample with the scanner and verify that correct data is displaying on the screen Scanner Main Cable To Computer Keyboard Port To Computer Keyboard PC AT Keyboard Wedge Connection gt PS 2 Keyboard Wedge Connection Plug the 5P DIN female connector of the slave cable into the 5P DIN male connector of the main cable of the scanner Then connect the rest of the connectors to the computer keyboard port and PS 2 keyboard PC AT Keyboard Wedge Connection Plug the 6P Mini DIN male connector of slave cable into 6P Mini DIN female connector of the main cable of the scanner Then connect the rest of the connectors to the compu
31. e is convenient for high speed bar code reading Toggle Mode Repeat Reading The toggle mode is very similar to the Alternative Mode without the pre defined auto power off duration concern When this operation mode is selected you must press the trigger to turn on the light source of the scanner The scanner keeps the light source turned on until you press the trigger again Programming the Scanner Diagnostic Mode Test Reading This operation mode is specifically designed for diagnostic purposes When this operation mode is selected the light source of the scanner is forced on without regard for other programmable parameters such as double scan verification redundancy and so forth scanning Tolerance Printing Quality Control This parameter provides the user with a helpful tool to use when the printing quality of the bar code is poor This is a programmable feature in IT3220 units with software revision AXX and 3060 80B with software revision CXX Units using IT3220 revision BXX and feature later software revisions VT3060 80B DXX automatically without any extra programming scanners perform this To reduce the error reading rate further we also recommend that you limit the number of enabled symbologies to only those that you need to read and to also limit the minimum and maximum reading of each enabled bar code symbology Programming the Scanner peration Control o III Trigger Mode Buzz
32. eamble Postamble amp Delay Setting PROGRAM END Exit Family Code Selection Parameter Selection Option Code Record Suffix None RETURN TAB SPACE ENTER Numeric Key Pad User defined character 1 character 5 00 7F Preamble None N I 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Postamble None FIN 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Character Frame Control None 00 99 msec 2 digits Scan 2 digits from the option code chart in the Appendix Intermessage Delay None 00 99 x5 msec 2 digits Scan 2 digits from the option code chart in the Appendix Intercharacter Delay None 00 99 msec 2 digits Scan 2 digits from the option code chart in the Appendix FACTORY DEFAULT 3 22 Programming the Scanner INIMIII Keyboard Interface Controt III Caps Lock Control amp Emulation Setting PROGRAM END Exit Family Code Selection Parameter Selection Option Code Caps Lock Off State 9 Caps Lock On State Auto Detect PC AT PS 2 Keyboard Replacement and DOS V Machines only Caps Lock Control Function Key Emulation Enable ASCII 00 31 code as keyboard function code output Refer to page A 5 Keyboard Function Code Table for details Key Pad Emulation Disable key pad emulation Enable numeric output a
33. ee 3 times Medium around 3 4 seconds Long around 5 6 seconds Extremely long around 7 8 seconds Pulse Driven Duty 1 2 duty cycle 2 3 duty cycle 3 4 duty cycle 4 5 duty cycle Dollar Sign Control Dollar sign output as FACTORY DEFAULT The Debounce Time Control feature is available in the IT3220 prior to software revision B and in the VT3060 3080 prior to software revision D Units using later software revisions perform this function automatically Dollar sign output as Japanese Yen 3 31 Programming the Scanner eee ee eee Preamble Postamble Data Length amp Symbol ID Trans PROGRAM END Exit Family Code Selection Parameter Selection Option Code Preamble None FIN Il 1 15 characters use hex value for each character 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Postamble None 4 FIN 1 15 characters use hex value for each character 00 7F FIN Maximum 15 character input scan FIN to terminate this selection Data Length Transmission Disable Ml Enable 2 digits data length transmission If data length exceeds 99 3 digit data length will be transmitted Code ID Transmission Disable Code ID transmission Enable prefix Code ID transmission Enable suffix Code ID transmission Data Pass Control Disable format match required 9 Enable both prefix and suffix Code ID transmissi
34. elect 2 check digit verification Disable check digit transmission Enable 1 check digit transmission Enable 2 check digit transmission Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix Disable check digit transmission Enable check digit transmission Default 03 Minimum length Scan 2 digits from the option code chart in the Appendix Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix 3 18 END Exit Option Code 2 digits 2 digits 2 digits 2 digits Programming the Scanner Symbology Programming MSI Plessey Code 128 amp UCC EAN 128 Setting PROGRAM Family Code Selection Parameter Selection MSI Plessey Settings Select MOD 10 check digit 9 Select MOD 10 10 check digit Select MOD 11 10 check digit Disable check digit transmission Enable 2 check digit transmission MSI Plessey Min Length Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix MSI Plessey Max Length Default 99 Maximum length Scan 2 digits from the option code chart in the Appendix Code 128 EAN 128 Settings Disable function code conversion Ill Il Enable function code conversion Code 128 EAN 128 Min Length Default 04 Minimum length Scan 2 digits from the option code chart in the Appendix
35. elect desired bar code symbologies for organizer control and provides a maximum of two identified positions to send the data before or after It also allows you to control the transmitted data including or excluding the data of the identified position Please refer to the application example on the next page for details While the Data Organizer is enabled it arranges only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Please refer to the next page for information about the Bar Code Selection and Position Calculation of Data Organizer To determine the hex value for the Character refer to the HEX ASCII Table listed on page A 6 Refer to page 3 12 for 2 digit symbology option code 3 36 Programming the Scanner Select a Bar Code Symbology You can use the Condensed Data Editor for an advanced transmission arrangement with one or all bar code symbologies If you scan 00 to select all types the scanner arranges all incoming data to meet your pre defined format If you want to select only one type of bar code please select one of the option codes listed below Codabar NW 7 06 Code 25 Family 08 Code 11 10 UK Plessey 12 MSI Plessey 11 UPC E 03 UPC A 02 Telepen 13 Code 128 01 UCC EAN 128 01 Code 39 07 Code 93 09 EAN CAN JAN 8 05 EAN CAN JAN 13 04 Code 32 07 Position Calculation Data Formatter
36. er Tone Scanning Tolerance 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code Operation Mode Low Power mode Low Power triggering Manual trigger External triggering Level mode Auto power off Alternative mode Periodic power off Presentation mode Pulse driven reading Auto trigger mode Continued power on Toggle mode Repeat reading Diagnostic mode Test reading Buzzer Tone Adjust Buzzer tone mute Buzzer tone low Buzzer tone medium Buzzer tone high Buzzer tone extremely high Good read beep before data transmission 9 Good read beep after data transmission Power on beep No power on beep Scanning Tolerance Regular standard printing quality esea Printing Quality Control FACTORY DEFAULT Poor critical printing quality Please read the Scanning Tolerance information on page 3 28 before attempting to program this feature 3 29 Programming the Scanner Advanced Operation Control This section allows the user to program the following parameters for advance operation control The definitions of each parameter are described below Reread Delay This feature is designed to inhibit the scanner from reading the same bar code within a certain period of time The time period can be programmed for immediate short medium or long time out duration Another selection Force Verification does not allow reading of the s
37. es listed below Configuration Procedure Disable Data Editor Pass Control no check in box Disable Select Using 1 Rule Set Applied Bar Code to Code 39 Set Valid ASCII Range to Numeric Select Using Match 1 Set Matched Data to 99 and set Start Position to 1 Set Original Field to Divide scanned data into 4 fields Set Field Divided By of F1 to Fixed Length of 2 set Field Divided By of F2 to Fixed Length of 4 set Field Divided By of F3 to Fixed Length of 6 set Field Divided By of F4 to Fixed Length of 2 Then the Data Editor assigns the remaining 2 digits as Last Field LF automatically Please note that if the Code 39 bar code label is printed with Check Digit the last field will have 3 digits Programming the Scanner Set Added Field to Insert 3 Added Fields set AF 1 Added Field 1 to AA Set AF2 to S N Set AF3 to TAB Hex 09 Set Transmission Sequence user defined transmission sequence to LF AF3 AF1 F2 AF3 AF2 F3 and AF3 3 5 Programming the Scanner Bar Code Programming Menu The bar code commands are specially designed Proprietary bar code labels that allow you to set the scanner s internal programming parameters The three m
38. haracters 1 character 1 character 3 24 Programming the Scanner Serial Interface Control Baud Rate amp Data Frame Setting 4 PROGRAM END Exit Option Code Family Code Selection Parameter Selection Handshaking Protocol None free running mode ACK NAK software handshaking RTS CTS hardware handshaking Baud Rate BPS Data Frame Time Out Control Xon Xoff software handshaking 38 4K BPS 19 2K BPS 9600 BPS 4800 BPS 8 None 1 9 8 Odd 1 6 Even 1 8 Space 1 6 Mark 1 6 None 2 7 Odd 1 7 Even 1 None 200 mseconds 500 mseconds 2400 BPS 1200 BPS 600 BPS 300 BPS 7 Space 1 7 Mark 1 7 None 2 7 Odd 2 7 Even 2 7 Space 2 7 Mark 2 1 second 2 seconds 5 seconds User defined value Seconds e Oo N gt O 6 2 digits FACTORY DEFAULT When the RTS CTS Hardware Handshaking option is selected the RTS request to send and CTS clear to send signals will be issued before normal data communication This option is very helpful to ensure the reliability of data communication When the ACK NAK Software Handshaking option is selected the scanner waits for an ACK acknowledge or NAK not acknowledge from the host computer after each data transmission If the NAK is received the scanner will re send the data until receiving ACK The Time Out Control is a pre defined delay time for the scanner to wait for handshaking acknowledgment
39. he Caps Lock Off state then the scanner will perform normal data transmission If the Caps Lock state is on select the Caps Lock On state If you select Auto Detect the scanner performs special transmission handshaking without changing the status of the Caps Lock switch 3 23 Programming the Scanner MII SeriatInterfacecontrei__ iif Record Suffix Handshaking amp Time Out Setting 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code STX ETX Control Disable STX ETX transmission 0 Enable STX ETX transmission 1 STX ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface Record Suffix None CR ODH 4 E2 CRLF ODOAH TAB 09H SPACE 20H EOT 04H 6 User defined character 1 character 7 00 7F Preamble None FIN N I 1 15 characters iA Maximum 15 character input scan FIN to terminate this selection Postamble None FIN 1 15 characters 00 7F FIN Maximum 15 character input scan FIN to terminate this selection FACTORY DEFAULT The record suffix and postamble differ in that the record suffix is always last and follows a postamble Serial Interface Message String Data Length Prefix Symbol ID Scanned Data Suffix Symbol ID Postamble Record Suffix 1 character 1 15 characters 2 3 digits 1 or 2 characters variable length 1 or 2 characters 1 15 c
40. he information 1s stored in the scanner s internal Flash Memory ASIC or non volatile memory If you turn off the unit the Flash Memory ASIC or non volatile memory retains all programmed settings Programming the Scanner Program amp End System List amp Master Default Scan PROGRAM Scanner enters programming mode and inhibits all non programming functions Scanner lists the product information and revision number to host via selected host interface then issues the completion beep 3 short beeps Scan Scanner returns all programmable Scanner exits programming mode and stores all parameters in Flash Memory ASIC or non volatile memory then issues the completion beep 3 short beeps parameters to factory preset configurations then issues the completion beep 3 short beeps Please note that the scanner will take 3 4 seconds to store parameters in internal Flash Memory ASIC or non volatile memory after you scan the END Please do not turn off the power before the completion beep It may destroy all configured parameters 3 7 Selection Flow Diagrams EXAMPLE 1 Scan PROGRAM scan One of Family Codes Scan One of Option Codes Scan FIN If indicated Yes Repeat Selection No Programming the Scanner Enter programming mode Select one of desired programming families Select one or several 1st Scan Several Option Codes
41. ier Scan Program to enter the programming mode Scan Verifier Control and set bar code symbology to 08 Interleaved 2 of 5 scan Identified Data Length and set the length to 16 Scan 1st Identified Character and set the identified position to 00 then set the identified character to 39 Hex value for 9 Data Formatter Scan Formatter Control and set bar code symbology to 08 Scan 151 Insertion and set the identified position to 06 then inserted characters to 09 Hex value for TAB 53 Hex value for S 4E Hex value for N Scan 2nd Insertion and set the identified position to 12 then inserted character to 09 Finally you must scan the FIN Finish code to terminate this selection Scan 3rd Insertion and set the identified position to 16 then inserted character to 09 Finally you must scan the FIN Finish code to terminate this selection Data Replacer Scan Replacer Control and set bar code symbology to 08 Scan 1st Replacement and set the identified position to 00 then replaced character to 41 Hex value for A At this point the data string is as follows A81025 TAB SN123456 TAB 9876 TAB We still need to delete the 98 from the string to get the desired output Data Organizer Scan Organizer Control and set bar code symbology t
42. ion code 3 33 Programming the Scanner MII Condensed Data Editor fifi Data Verifier Settings PROGRAM END Exit Family Code Selection Parameter Selection Option Code 2nd Option Code Verifier Control Disable FIN Select one bar code symbology 2 digits automatic termination Select all bar code symbologies 00 automatic termination Identified Data Length Disable FIN Enable 2 digit decimal value Determine the identified data length for verification 1st Identified Character Disable 4 FIN Enable 2 digit HEX 00 7F value 2nd Identified Character Disable 9 FIN Enable 2 digit HEX 00 7F value 2 digits checking position 1 identified character 3rd Identified Character Disable FIN value 2 digits checking position 1 identified character The Data Verifier is used to provide advanced verification for error free scanning and to work as an Embedded Data Transmitting Filter Enable 2 digit HEX 00 7F All data must conform to the Identified Bar Code Symbologies Identified Data Length and one to three Identified Characters in the checking position Otherwise the scanner will not transmit the data to the host computers but will instead issue 3 long beeps for verification error and skip the scanned data The Data Verifier checks only scanned data without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Please refer to page 3 37 for i
43. mmand l FIN Finish MoO HI END Exit HIHI System List Il mam mO i Master Default B M_DEFAULT 7 F Appendix A Sample Bar Codes Codabar Code 39 Interleaved 2 of 5 A13579B BC321 1234567890 Code 128 Code 93 Matrix 2 of 5 Code 128 123456 9 6543210 Code 2 of 5 EAN 13 UPC A 123456 9 780330 290951 0 123456 7890 5 Appendix A Bar Code System Command Bar Code System Command Set PC AT PS 2 Keyboard Wedge System Information List SYSLIST Keyboard Replacement Factory Default Setting M_DEFAULT RS 232 Serial Interface HHP SET Host Link A 9 HHP Upgrade your image 700 Visions Drive PO Box 208 Skaneateles Falls NY 13153 0208 3060 80 3220 UG Rev B
44. nformation about the Bar Code Selection and Position Calculation of Data Verifier To determine the hex value for the Character refer to the HEX ASCII Table on page A 6 Refer to page 3 12 for 2 digit symbology option code 3 34 Programming the Scanner MII Condensed Data Editor itt Data Replacer Settings PROGRAM END Exit Family Code Selection Parameter Selection Option Code 2nd Option Code Replacer Control Disable FIN Select one bar code symbology 2 digits automatic termination Select all bar code symbologies 00 automatic termination 1st Replacement Disable FIN Enable 2 digit decimal 00 7F value 2nd Replacement Disable FIN 2 digits identified position 1 replacement character Enable 2 digit decimal 00 7F value 2 digits identified position 1 replacement character 3rd Replacement Disable FIN value 2 digits identified position 1 replacement character FACTORY DEFAULT The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to select desired bar code symbologies for replacer control and provides Multiple Position Replacement in the identified position All data must conform to the Identified Bar Code Symbologies and one to three Identified Characters in the identified position While the Data Replacer is enabled it arranges only scanned da
45. o 08 Scan 1st Organization and set the identified position to 16 then set the data transmission to 0 before The character position which counts the added SN and TABs is identified as 00 01 02 so the 16 character is 9 The include exclude control which will be set to 0 for exclude in the last step of the instructions below determines that the 9 in the 16 position will not be sent All of the characters before the 16 position will be transmitted Scan 2nd Organization and set the identified position to 17 which is 8 in this case then set the data transmission to 1 to transmit all of the characters after position 17 Whether position 17 gets transmitted along with the string is determined by the include exclude control which in this case will be excluded in the next step Include Exclude Control Scan Include Exclude Control Scan 0 for transmitted data excluding the data of the identified position Scan END Exit to terminate the programming Customer Service 4 Customer Service Obtaining Factory Service HHP provides service for all its products through a service center located in Charlotte North Carolina Hong Kong the Netherlands and the United Kingdom To obtain warranty or non warranty service return the unit to HHP postage paid with a copy of the dated purchase record attached In the United States please
46. on The Data Editor is a very powerful Artificial Intelligence based data editing expert system provided specifically for the 3060B 3080B 3220 bar code scanners Through the Data Editor you can process the scanned data prior to transmitting in many ways such as Insert Delete Match Verify Replace Reorganize and Repeat Transmission It also allows you to arrange the transmission of scanned data to any specific format Due to the resources used by this system the Full feature Data Editor is only supported by HHP SET Through HHP SET all settings and configurations can be done on screen under Windows 95 98 NT environment A Condensed Version Data Editor is provided here in the manual and is utilized by scanning the programming bar codes When Data Pass Control is disabled all input data must conform to an edited format or the scanner does not transmit the input data to the host Enable format match not required If data verifier is false the original scanned bar code data will be transmitted 3 32 Programming the Scanner MII Condensed Data Editor III Data Formatter 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code 2nd Option Code Formatter Control Disable FIN Select one bar code symbology 2 digits automatic termination Select all bar code symbologies 00 automatic termination 1st Insertion Disable FIN Hex value for each Enable 2 digits character FIN
47. ou must enable this option WPC Selection Basic 26 26 With 2 digit With 5 digit Enable Enable UPC EAN JAN CAN Length Check Digit Numeric System Addendum Addendum Standardization Expansion UPC A 1 UPC E EAN JAN CAN 13 pet NC 2 NC EAN JAN CAN 8 8 Nt co _ 1 3 15 PROGRAM Family Code Selection EAN CAN JAN Settings IATA Settings 9 FACTORY DEFAULT Programming the Scanner Symbology Programming EAN JAN CAN amp IATASetting Parameter Selection Select EAN without supplement digits Select EAN with only 2 supplement digits Select EAN with only 5 supplement digits Select EAN with 2 5 supplement digits Disable EAN 8 expansion Enable EAN 8 expansion Disable EAN 13 check digit transmission Enable EAN 13 check digit transmission Disable EAN 8 check digit transmission Disable ISBN ISSN Conversion reading check Enable ISBN ISSN Conversion reading check Select 15 digit fixed length IATA checking Select variable length IATA Disable check digit verification Enable check digit automatic verification Enable S N checking digit verification only Enable CPN checking digit verification only Enable CPN Airline and S N check digit verification Disable start stop symbol transmission Enable start stop symbol transmission Disable check digit transmission Enable check digit transmission 3 16 END Exit Option Code Programming the Scanner NIN _SymbologyProgrammis
48. ptionally fast and accurate scanning capabilities The unique decoding engine gives the Since the built in flash memory makes the IT3220 field upgradeable the scanner s programming is always up to date The VALUETEAM 3060B and 3080B CCD scanners are ideal entry level bar code readers They offer excellent reading performance with the most often used terminals and PCs for point of sale or general purpose applications Both the VT3060B and VT3080B have Flash Memory are compact in size are comfortable to use and have been designed to take the punishment of daily use About This Manual This User s Guide provides installation and programming instructions for both the IT3220 and the VT3060B 3080B Customer support and warranty information is also included HHP s scanners are factory programmed for the most common terminal and communications settings If you need to change these settings programming is accomplished by either scanning the bar codes in this user s guide or by using HHP SET a Windows based utility that allows the user to perform on screen configurations and software upgrades Please verify the information displayed on the product label matches the information on the outer box label If any difference is found please contact your vendor immediately Getting Started Outer Box Label Outer Box Label lt SHHP IMAGETEAM MID RANGE LINEAR lt gt HHr IMAGETEAM MID RANGE LINEAR IMAGER UNIVER
49. r a TAB For some of the above key functions to work correctly it is necessary to disable the NumLock key A 5 Appendix A ASCII Input Shortcut To configure the user definable parameters of the scanner via HEX ASCII Reference Table the programming bar codes you will be asked to scan your 0 an 1 2 3 5 6 7 desired ASCII value in HEX form You have to refer to the pe space o Pp op HEX ASCII Table for details A Di BO gt Example J O oO If you want the scanned data output leading with a Dollar Sign you have to set the Preamble to The configuration Z o Al A gt procedure is listed below for reference SYN Scan the system command PROGRAM listed on page 3 22 to enter programming mode Scan family code PREAMBLE to select this family In the Hex ASCII Table you will find the HEX value of is 24 Scan the option code 2 listed on the foldout back cover Scan the option code 4 listed on the foldout back cover Scan the system command FIN Finish to terminate Preamble setting Example ASCII A gt HEX 41 ASCII a gt 61 Scan the system command End to exit the programming Ml High Byte of HEX Value Low Byte of HEX Val mode for normal operation E Low Byte o alue A 6 Appendix A Bar Code Command Menu Option Code 0 9 A F System Co
50. rt stop symbol transmission Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Codabar Min Length Default 04 Minimum length 2 digits Scan 2 digits from the option code chart in the Appendix Codabar Max Length Default 99 9 Maximum length 2 digits Scan 2 digits from the option code chart in the Appendix pt FACTORY DEFAULT 3 14 Programming the Scanner III Symbology Programming if UPC A amp UPC E Setting 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code UPC Family Settings Select UPC without supplement digits Select UPC with only 2 supplement digits Select UPC with only 5 supplement digits Select UPC with 2 5 supplement digits Disable UPC E ex pansion Enable UPC E expansion Disable UPC standardization 9 Enable UPC standardization Disable UPC numeric system Disable UPC A check digit transmission Enable UPC A check digit transmission Disable UPC E check digit transmission Disable UPC leading 1 portion 9 Enable UPC leading 1 portion UPC E amp EAN 8 Expansion Expand the 7 digit UPC E and 8 digit EAN to 12 digit UPC A and 13 digit EAN 13 UPC A E Standardization Expand the 7 digit UPC E and 12 digit UPC A to 8 digit UPC 8 to 13 digit EAN 13 with 1 zero insertion UPC Lead 1 Numeric System Enable to read UPC leading with the 1 numeric system y
51. s key pad Num Lock On output Upper Lower Case Normal case neglect the upper lower case control 9 FACTORY DEFAULT Character Frame Control is used to adjust the timing gap between bytes within one character data output by the scanner Intercharacter Delay is a time delay between data characters output by the scanner These two parameters are used to synchronize data communication when 1 the data transmission speed is too fast characters may be skipped 2 multitasking operation system or host computers in a network may slow down the keyboard handling 3 various notebook or desktop PC systems require different timing parameter settings Please always add one extra unit as a safety margin when adjusting these two parameters Inverse case change all characters output to inverse case Upper case force all characters output as upper case Lower case force all characters output as lower case Intermessage Delay is a time delay between messages output by the scanner Increasing this delay will help host applications process the incoming data on time The Caps Lock Control and Key Pad Emulation functions are only available for IBM PC AT PS VP PS 2 series personal computers and compatible machines If you select other host interfaces these selections will not perform the above functions Please check the actual Caps Lock state in use while the software application is running If the Caps Lock state is off select t
52. ta without Preamble Postamble STX ETX Data Length Prefix Suffix Symbology ID or Record Suffix Please refer to page 3 37 for information about the Bar Code Selection and Position Calculation of Data Replacer To determine the hex value for the Character refer to the HEX ASCII Table listed on page A 6 Refer to page 3 12 for 2 digit symbology option code Enable 2 digit decimal 00 7F 3 35 Programming the Scanner MII Condensed Data Editor fifi fi Data Organizer Settings 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code 2nd Option Code Organizer Control Disable FIN Select one bar code symbology 2 digits automatic termination Select all bar code symbologies 00 automatic termination 1st Organization Disable FIN Direction Enable 2 digit decimal 0 Before 9 8 value 1 After 2 digits identified character position Transmit data before after this position 2nd Organization Disable FIN Direction Enable 2 digit decimal 0 Before 9 value 1 After 2 digits identified position Transmit data before after this position Include Exclude Control Transmitted data excluding the data of identified position Transmitted data including the data of identified position FACTORY DEFAULT The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals It allows you to s
53. ter Selection Option Code Code 39 Family Settings Select Standard Code 39 Select Full ASCII Code 39 Select Code 32 Italian Pharmaceutical Disable start stop symbol transmission Enable start stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Code 39 Min Length Default 04 Minimum length 2 digits Scan 2 digits from the option code chart in the Appendix Code 39 Max Length Default 99 9 Maximum length 2 digits Scan 2 digits from the option code chart in the Appendix FACTORY DEFAULT Selecting Full ASCII Code 39 disables Code 32 both options may not be enabled at the same time Code 39 and full ASCII may be enabled at the same time and Code 32 and Code 39 standard my be enabled at the same time 3 13 Programming the Scanner MMI Symbotogy Programming IRMI Codabar NW 7 Setting 4 PROGRAM END Exit Family Code Selection Parameter Selection Option Code Codabar Settings Select Codabar standard format Select Codabar CLSI format Select Codabar CX format Disable start stop symbol transmission Enable ABCD ABCD start stop symbol transmission Enable abcd abcd start stop symbol transmission Select Codabar ABC format Enable ABCD TN E start stop symbol transmission Enable abcd tn e sta
54. ter keyboard port and PC AT keyboard RS 232 Serial Interface RS 232 Serial interface is among one of the most popular applications of bar code scanners Before connecting your scanner to the RS 232 communication port of the host machine please follow the procedures illustrated below Scanner Main Cable To RS 232 Port l 6 1 Jp x l TEE of W e T P gt RS 232 Serial Interface Connection Terminal Interfaces RS 232 Interface Installation Verify the RS 232 port COM1 or COM2 available on your computer system Plug the RJ45 phone plug of the main cable into the RS 232 cable adapter Plug the 9 pin or 25 pin D sub connector of the cable converter into the desired serial port on your system Attach the power outlet plug of the optional AC power adapter to the side power jack of the D sub connector You will hear the power on beep twice to signal that the scanner is ready for bar code reading Scan the RS 232 Serial Interface bar code to configure the scanner to perform the RS 232 serial interface operation RS 232 Serial Interface Scanning the RS 232 interface bar code above configures the scanner s serial parameters to 9600 Baud 8 data bits no parity and 1 stop bit no handshaking Please note that the RS 232 settings of the host system must match the scanner s RS 232 settings f you are in the Windows environment you may use the Hyper Terminal to test Standard RS 23
55. tive or your local distributor Latin America Office Hand Held Products Inc 5117 Castello Drive Suite 1 Naples FL 34103 Telephone 239 263 7600 Fax 239 263 9689 Application Support If you need assistance installing or troubleshooting your scanner please call your distributor or the nearest HHP Application Support office listed below You also can obtain assistance from our website at www hhp com Customer Service North America Latin America Telephone 315 685 2476 8 a m to 8 p m EST Telephone Int 56 2942 2495 or 2942 8371 or in the U S 800 782 4263 E mail 18 support hhp com Fax number 315 685 4960 E mail tech support hhp com Europe Telephone European Ofc Int 31 40 242 4486 U K Ofc Int 44 1925 240055 E mail euro support hhp com Asia Telephone Int 852 2511 3050 or 2511 3132 E mail asia support hhp com 4 3 Limited Warranty 5 Limited Warranty Hand Held Products Inc d b a HHP HHP warrants its products to be free from defects in materials and workmanship and to conform to HHP s published specifications applicable to the products purchased at the time of shipment This warranty does not cover any HHP product which is 1 improperly installed or used 11 damaged by accident or negligence including failure to follow the proper maintenance service and cleaning schedule or 111 damaged as a result of A modification or alteration by the purchaser or other p
Download Pdf Manuals
Related Search
Related Contents
Air King BFQ50 User's Manual Lenovo ThinkPad Edge 330 Arena`s Home Page Calibreur de processus multifonctionnel mode d`emploi en 2015 - Lycée Edouard Vaillant 6821-O-ins EX8 JET 601 / 802 JET 601 INOX / JET 802 INOX JET 1002 INOX USER`S MANUAL Mitsubishi Programmable Controller Training Copyright © All rights reserved.