1. 4 308415 Setup General Information NOTE Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing NOTE Always use Genuine Graco Parts and Acces sories available from your Graco distributor Refer to the Product Data Sheet for your pump Form No 305756 If you supply your own accessories be sure they are adequately sized and pressure rated for your system Fig 2 is only a guide for selecting and installing sys tem components and accessories Contact your Graco distributor for assistance in designing a system to suit your particular needs Prepare the Operator All persons who operate the equipment must be trained in the safe efficient operation of all system components as well as the proper handling of all fluids All operators must thoroughly read all instruction manuals tags and labels before operating the equip ment Prepare the Site The Premier pumps require 6 4 m3 min 230 scfm of compressed air while operating at 0 67 MPa 6 7 bar 97 psi air pressure and 60 cycles per minute Ensure that you have an adequate compressed air supply Refer to Fig 2 Bring a compressed air supply line A from the air compressor to the pump location Be sure all air hoses A are properly sized and pressure rated for your system Use only electrically conductive hoses The air hose should have a 3 4 npt m thread Install a bleed type shutoff valve B in t
2. 10 Clean the tip guard spray tip and fluid filter ele Flush with a fluid that is compatible with the fluid you ment separately then reinstall them are pumping and with the wetted parts in your system Check with your fluid manufacturer or supplier for 11 Clean the inside and outside of the suction tube recommended flushing fluids and flushing frequency 24 10 308415 KEY 5 7 8 24 30 69 70 71 Pump Air Regulator Suction Hose Fluid Filter Suction Tube Red Handled Bleed Type Master Air Valve required for pump Fluid Shutoff Valve Air Line Male Coupler Air Line Female Coupler 102 Airless Spray Gun 103 Electrically Conductive Fluid Supply Hose D F f Torque to 129 142 Nem 103 Fluid Drain Valve required Packing Nut Wet Cup 95 105 ft lb Fig 3 Operation Model 237158 Shown 308415 05901C 11 Ref No 1 4 4a 4b 4c 4d 5 7t 8 10 11 12 13 15 16 17 221 23 241 25t 27 28 29 30 12 Part No 236932 236943 112860 107146 154628 112853 112728 237522 237069 190122 190121 100023 101566 151519 205447 186447 112839 102806 197682 191635 100101 100322 100088 113163 308415 Parts Part No 236489 Series B includes items 1 78 Part No 237158 Series B includes items 1 106 Description Qty PUMP Premier 74 1 ratio See manual 308357 for parts 1 CART
3. 102 See the gun instruction manu spray tip in the gun as explained in the gun manu al 2 Close the air regulator 5 and bleed type air valves B 30 2 Open the air regulator 5 slowly Use the regulator to control pump speed and fluid pressure Always 3 Close the fluid drain valve D use the lowest air pressure necessary to get the desired results Higher pressures cause premature 4 Engage the air line coupler 71 with the mating tip and pump wear coupler 70 attached to the air manifold 32 and twist with a wrench to lock NOTE To open the air regulator turn the T handle in clockwise To close the regulator turn the handle 5 Check that all fittings throughout the system are counterclockwise To lock the regulator setting tighten tightened securely the jam nut 6 Place the suction tube 24 into the fluid supply A WARNING container 7 Open the fluid shutoff valve 69 COMPONENT RUPTURE HAZARD To reduce the risk of overpressurizing 8 Open the bleed tvpe air valves B 30 uH ikali your system which could cause compo nent rupture and serious injury never 9 Hold a metal part of the gun 102 firmly to the side exceed the specified Maximum Incoming Air Pres ofa grounded metal pail and hold the trigger open sure to the pump see the Technical Data on t page 14 10 Slowly open the air regulator 5 until the pump Starts 3 With the pump and lines primed and with ade quate air
4. NIPPLE 1 in npt 1 MANIFOLD air 1 in npt f inlet 1 in npt m outlet 3 8 npt 1 4 npt and 1 8 npt ports 1 HOSE air 1 in npt mbe 2 ft 0 61 m long 1 PLUG pipe 1 8 npt 1 PLUG pipe 3 8 npt 1 GAUGE air pressure 0 200 psi 0 14 bar range 1 ELBOW street 1 4 npt m x f 1 LOCKNUT with nylon insert 1 4 20 unc 3b 1 BOLT eye 1 STRAP rubber 1 NUT 1 3 8 12 unf 2a carbon steel 1 O RING Viton 1 PLUG pipe 1 4 npt 1 GROUND WIRE AND CLAMP 1 VALVE ball 3 8 npt mbe 2 COUPLER air line 3 4 npt m 1 COUPLER air line 3 4 npt f 1 RELIEF VALVE air 7 6 bar 110 psi 1 CAP valve 1 BUSHING 3 4 npt f x 1 in npt m 1 ELBOW street 90 3 8 npt m x 3 8 npt f 2 GASKET 3 HOSE AND GUN KIT Includes items 102 106 1 AIRLESS SPRAY GUN See manual 312145 for parts 1 HOSE fluid nylon 10 mm 3 8 in ID 3 8 npsm fbe 15 2 m 50 ft long 1 HOSE fluid nylon 6 3 mm 1 4 in ID 1 4 npsm fbe 1 8 m 6 ft long 1 NIPPLE reducing 3 8 npt x 1 4 npt 1 These parts are included in Air Regulator Kit 236989 t These parts are included in Siphon Kit 237068 Parts Part No 236489 Series B includes items 1 78 Part No 237158 Series B includes items 1 106 SERRA SS Ze Za Z A SAN IAN AI N Ty EEE ae 05900E 308415 13 Technical Data Category Data Maximum fluid working pressure 50 0 MPa 500 bar 7252 psi Maximum air inpu
5. close to the pump but upstream from the bleed type master air valve 3 Screw the short whip hose 104 onto the nipple 105 e The air manifold 32 provides ports for connect 4 Screw the whip hose 104 onto the fluid inlet of ing lines to air powered accessories the spray gun 102 6 308415 Setup KEY SUPPLIED WITH ALL MODELS SUPPLIED WITH MODEL 237158 ONLY COMPONENTS YOU MUST SUPPLY 1 Pump 102 Airless Spray Gun A Electrically Conductive Air Supply Hose 4 Cart 103 Electrically Conductive Fluid Supply Hose B Bleed Ivpe Master Air Valve 5 Pump Air Regulator 104 Electrically Conductive Fluid Whip Hose for accessories 7 Suction Hose 105 Nipple C Air Line Moisture Trap and Drain Valve 8 Fluid Filter includes drain valve E Grounded 19 Liter 5 Gallon Pail 22 Pump Intake Bushing 24 Suction Tube 30 Red Handled Bleed Type Master Air Valve required for pump 32 Air Manifold 57 Ground Wire required see page 5 for installation instructions 69 Fluid Shutoff Valves 70 Air Line Male Coupler 71 Air Line Female Coupler 73 Air Relief Valve D Fluid Drain Valve required Detail of Air Line Connections Keep this valve capped and closed unless you are using a second hose and gun 102 SSN K AU Y KA 69 24 PSS SSS SAY TSS 103 LEE TS EE Model 237158 Shown Fig 2 05901B 308415 7 Operation Pressure Relief Pro
6. or compatible solvent See Fig 3 A WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure at left The packing nut is torqued at the factory and is ready for operation If it becomes loose and there is leaking from the throat packings relieve pressure then torque the nut to 129 142 Nem 95 105 ft lb using the supplied wrench Do this whenever necessary Do not overtighten the packing nut Flush the Pump Before First Use The pump is tested with lightweight oil which is left in to protect the pump parts If the fluid you are using may be contaminated by the oil flush it out with a compatible solvent See Flushing on page 10 Using the Airless Spray Gun Before operating the equipment read the instruction manual supplied with the gun Spray some test patterns before doing any finished work Refer to the gun manual for detailed information on correct spraying technique Operation Set the Air and Fluid Pressure A CAUTION A WARNING To avoid tip over the cart must be on a flat and level surface Failure to follow this caution could result in injury or equipment damage To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Prime the Pump Pressure Relief Procedure on page 8 1 T ji 3 ipsa ki guard and spray tip 1 Relieve the pressure Install the tip guard and ae the gun
7. portable Includes replacement items 4a 4d 1 WHEEL 2 RING retaining 2 WASHER flat 0 77 in size 2 PLUG tube 2 AIR REGULATOR See manual 308168 for parts 1 HOSE suction nylon 25 mm 1 in ID 1 in npt mbe 1 8 m 6 ft long 1 FLUID FILTER with 250 micron 60 mesh stainless steel element and drain valve See manual 307296 for parts 1 ADAPTER 3 4 npt m carbon steel NIPPLE carbon steel 1 in npt x 1 3 8 12 unf 2a WASHER flat 3 8 in size LOCKNUT with nylon insert 3 8 16 NIPPLE 1 4 npt x 1 8 npt COUPLING hose reusable 1 4 npsm f swivel 1 TUBE drain nylon 0 6 mm 1 4 in ID 127 mm 5 in long 1 BUSHING reducer 2 in npt m x 1 in npt f zinc plated iron 1 UNION adapter swivel 1 in npt m x 1 in npsm f 1 TUBE suction aluminum 1 STRAINER fluid inlet stainless steel 1 SCREW cap hex hd 3 8 16 unc 2a 1 in 25 mm long 1 WASHER lock 3 8 in size ELBOW street 90 2 in npt m x a 00 2 in npt f 1 BLEED VALVE red handled 1 in npt fbe 1 Ref No 31 32 33 34 35 38 39 41 42 43 45 46 51 57 69 70 71 73 74 75 77 78 101 102 103 104 105 Part No 158585 189978 236990 100139 101754 100960 100840 102040 109511 109510 190123 112855 100721 238909 237304 113429 113430 113498 113562 158586 155699 190072 238615 XTR704 H73850 H72506 164856 Description Qty
8. pressure and volume supplied the pump 11 Cycle the pump slowly until all air is pushed out will start and stop as you open and close the gun and the pump and hoses are fully primed 12 Release the gun trigger and lock the trigger safety The pump should stall against pressure A CAUTION Do not allow the pump to run dry It will quickly accelerate to a high speed causing damage If your pump is running too fast stop it immediately and 13 If the pump fails to prime properly open the drain valve D Use the drain valve as a priming valve until the fluid flows from the valve Close the valve check the fluid supply If the container is empty and NOTE When changing fluid containers with the hose air has been pumped into the lines refill the con and gun already primed open the drain valve D to tainer and prime the pump and the lines or flush and help prime the pump and vent air before it enters the leave it filled with a compatible solvent Eliminate all hose Close the drain valve when all air is eliminated air from the fluid system 308415 9 Operation Shutdown and Care of the Pump A CAUTION A WARNING Never leave water or water base fluid in the pump overnight If you are pumping water base fluid flush with water first then with a rust inhibitor such as mineral spirits Relieve the pressure but leave the rust inhibitor in the pump to protect the parts from corrosion To reduce the risk of serious injury
9. whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 For overnight shutdown stop the pump at the bottom of its stroke to prevent fluid from drying on the ex posed displacement rod and damaging the throat A WARNING packings Relieve the pressure To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 Always flush the pump before the fluid dries on the displacement rod See Flushing below a 1 Relieve the pressure Flushing 2 Remove the tip guard and spray tip from the gun A WARNING See the gun instruction manual FIRE AND EXPLOSION HAZARD 3 A es Ha Sea from the fluid filter 8 Before flushing read the section FIRE See eRe OR EXPLOSION HAZARD on page 4 Be sure the entire system and flushing pails are properly grounded Refer to Grounding on page 5 5 4 Place the suction tube 24 in a container of sol vent Hold a metal part of the gun firmly to the side of a grounded metal pail Flush the pump 6 Start the pump Always use the lowest possible e Before the first use fluid pressure when flushing e When changing colors or fluids 7 Trigger the gun 8 Flush the system until clear solvent flows from the e Before fluid can dry or settle out in a dormant pump gun check the pot life of catalyzed fluids l 9 Relieve the pressure e Before storing the pump
10. Instructions Parts List GRACO 74 1 RATIO PREMIER CARBON STEEL Cart Mounted Airless Package 308415P 77 WITH DURA FLO 1100 DISPLACEMENT PUMP 50 0 MPa 500 bar 7252 psi Maximum Working Pressure 0 67 MPa 6 7 bar 97 psi Maximum Air Inlet Pressure Part No 236489 Series B With High Pressure Fluid Filter Part No 237158 Series B With High Pressure Fluid Filter hose and gun Important Safety Instructions GERG D 4g Read all warnings and instructions in this manual Save these instructions See page 2 for model numbers and maximum working pressures PROVEN QUALITY LEADING TECHNOLOGY lt n GRACO INC P 0 BOX1441 MINNEAPOLIS MN 55440 1441 C PE Copyright 1994 Graco Inc is registered to I S EN ISO 9001 2 G HO03 Table of Contents Symbols WETTING S oat Sit Mach cute Maa ta 2 Warning Symbol SOUP kadar a a ar needed 5 Operation 0 e 8 A WARNING PAM aed ois e i a debs date age eee he 12 Technical Data sree debiti eiaets ahr eh heats 14 This symbol alerts you to the possibility of serious Dimensions St ai i bi ies aktar sted ely dears 15 injury or death if you do not follow the instructions Graco Standard Warranty 20020005 16 Caution Symbol A CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions A WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause
11. cedure A WARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an injury from injection splashing fluid or moving parts follow the Pressure Relief Procedure whenever you e are instructed to relieve the pressure e stop spraying e check or service any of the system equipment e or install or clean the spray tips 1 Lock the gun trigger safety 2 Close the red handled bleed type master air valve 30 required in your system 3 Open the fluid shutoff valve 69 4 Unlock the gun trigger safety 5 Hold a metal part of the gun firmly to the side of a grounded metal pail and trigger the gun to relieve pressure 6 Lock the gun trigger safety 7 Open the drain valve D required in your system having a container ready to catch the drainage 8 Leave the drain valve open until you are ready to spray again If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually then loosen completely Now clear the tip or hose 8 308415 Packing Nut Wet Cup Before starting fill the packing nut F 1 3 full with Graco Throat Seal Liquid TSL
12. g continuity when flushing or relieving pressure hold a metal part of the spray gun firmly to the side of a grounded metal pail then trigger the gun 308415 5 Setup Supplied Components e The air relief valve 73 opens automatically to prevent overpressurization of the pump Refer to Fig 2 e The fluid filter 8 includes a 60 mesh 250 mi cron stainless steel element to filter particles from A WARNING the fluid as it leaves the pump It includes the fluid drain valve D which is required in your system to relieve fluid pressure in the hose and gun see the A red handled bleed type master air valve 30 and WARNING above a fluid drain valve D are supplied These accesso ries help reduce the risk of serious injury including fluid injection and splashing of fluid in the eyes or on the skin and injury from moving parts if you are adjusting or repairing the pump e The suction hose 7 and tube 24 allow the pump to draw fluid from a 19 liter 5 gallon pail E e Two fluid shutoff valves 69 are supplied at the fluid filter outlets Attach the fluid hose 103 to one of the valves Keep the other valve capped and closed at all times unless you are using a second hose and gun The bleed type master air valve relieves air trapped between this valve and the pump after the valve is closed Trapped air can cause the pump to cycle unexpectedly Locate the valve close to the pump The fluid drain valve assists in rel
13. he air line to isolate the air line components for servicing Install an air line moisture trap and drain valve C to help re move moisture from the compressed air supply Keep the site clear of any obstacles or debris that could interfere with the operator s movement Have a grounded metal pail available for use when flushing the system or draining the fluid filter Grounding A WARNING FIRE AND EXPLOSION HAZARD Before operating the pump ground the system as explained below Also read the section FIRE OR EXPLOSION HAZ ARD on page 4 1 Pump use the ground wire and clamp supplied See Fig 1 Loosen the grounding lug locknut W and washer X Insert one end of the ground wire 57 into the slot in lug Z and tighten the locknut securely Connect the other end of the wire to a true earth ground W 0864 Fig 1 2 Air and fluid hoses use only electrically conductive hoses 3 Air compressor follow manufacturer s recommen dations 4 Spray gun ground through connection to a prop erly grounded fluid hose and pump 5 Fluid supply container follow your local code 6 Object being sprayed follow your local code 7 Solvent pails used when flushing follow your local code Use only metal pails which are conductive placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts the grounding continu ity 8 To maintain groundin
14. ieving fluid pres Connect the Suction Hose sure in the displacement pump hose and gun Triggering the gun to relieve pressure may not be sufficient Apply thread sealant to the suction hose 7 and screw it into the bushing 22 at the pump s fluid intake Screw the suction tube 24 onto the other end of the hose Attach the inlet strainer 25 to the tube e The red handled bleed type master air valve p 30 is required in your system to relieve air trapped Connect the Fluid Hoses and Gun between it and the air motor when the valve is closed see the WARNING above Be sure the bleed valve is easily accessible from the pump and is located downstream from the air regulator 5 NOTE Model 237158 includes a Hose and Gun Kit 101 which supplies fluid hoses a spray gun and connecting parts ref nos 102106 If you supply your own fluid hoses and gun be sure they are properly sized and pressure rated for your system Use only e With a wrench loosen and remove the female air electrically conductive hoses line coupler 71 Screw it onto the main air hose A Leave the mating coupler 70 attached to the 1 Connect the main fluid hose 103 to one fluid air manifold 32 shutoff valve 69 at the fluid filter 8 outlet 2 Screw the nipple 105 into the other end of the e The air regulator 5 controls pump speed and main fluid hose 103 outlet pressure by adjusting the air pressure to the pump Locate the regulator
15. mputation Fluid splashed in the eyes or on the skin can also cause serious injury Fluid injected into the skin might look like just a cut but it is a serious injury Get immediate surgi cal treatment Do not point the gun at anyone or at any part of the body Do not put your hand or fingers over the spray tip Do not stop or deflect leaks with your hand body glove or rag Do not blow back fluid this is not an air spray system Always have the tip guard and the trigger guard on the gun when spraying Check the gun diffuser operation weekly Refer to the gun manual Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 8 if the spray tip clogs and before cleaning checking or servicing the equipment Tighten all fluid connections before operating the equipment Check the hoses tubes and couplings daily Replace worn or damaged parts immediately Do not repair high pressure couplings you must replace the entire hose Fluid hoses must have spring guards on both ends to help protect them from rupture caused by kinks or bends near the couplings MOVING PARTS HAZARD st Moving parts such as the air motor rocker arms can pinch or amputate your fingers e Keep clear of all moving parts when starting or operating the pump e Before servicing the equipment follow the Pressure Relief Procedure on page 8 to prevent the equi
16. ot disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories equipment materials or components sold but not manufactured by Graco These items sold but not manufactured by Graco such as electric motors switches hose etc are subject to the warranty if any of their manufacturer Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties In no event will Graco be liable for indirect incidental special or consequential damages resulting from Graco supplying equipment hereunder or the furnishing performance or use of any produc
17. pment from starting unexpectedly 308415 3 A WARNING FIRE AND EXPLOSION HAZARD Improper grounding poor ventilation open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury Ground the equipment and the object being sprayed Refer to Grounding on page 5 If there is any static sparking or you feel an electric shock while using this equipment stop spray ing immediately Do not use the equipment until you identify and correct the problem Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed Keep the spray area free of debris including solvent rags and gasoline Electrically disconnect all equipment in the spray area Extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do not turn on or off any light switch in the spray area while operating or if fumes are present Do not operate a gasoline engine in the spray area TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin inhaled or swallowed Know the specific hazards of the fluid you are using Store hazardous fluid in an approved container Dispose of hazardous fluid according to all local state and national guidelines Always wear protective eyewear gloves clothing and respirator as recommended by the fluid and solvent manufacturer
18. t pressure 0 67 MPa 6 7 bar 97 psi Ratio 74 1 Pump performance data See pump manual 308357 Air consumption data See pump manual 308357 Air inlet size 1 in npsm f Fluid outlet size at fluid filter 3 8 npt m Fluid inlet size 2 in npt f Maximum operating temperature 82 C 180 F Wetted parts Pump See pump manual 308357 Fluid Filter See manual 307296 Suction Hose Tube and Fittings Polyethylene Stainless Steel Carbon Steel Nickel and Cadmium Plating Drain Tube and Fluid Hoses Nylon Viton is a registered trademark of the DuPont Co Sound Pressure Levels dBa measured at 1 meter from unit Input Air Pressures at 15 cycles per minute 0 28 MPa 2 8 bar 0 48 MPa 4 8 bar 0 63 MPa 6 3 bar 0 7 MPa 7 bar Air Motor 40 psi 70 psi 90 psi 100 psi Sound Power Levels dBa tested in accordance with ISO 9614 2 Input Air Pressures at 15 cycles per minute 0 28 MPa 2 8 bar 0 48 MPa 4 8 bar 0 63 MPa 6 3 bar 0 7 MPa 7 bar Air Motor 40 psi 70 psi 90 psi 100 psi C e8 88 77 80 ss 14 308415 05902C Pump Model A B Cc Width Across Weight Wheels 236489 1270 mm 50 in 864 mm 34 in 1864 mm 34 in 737 mm 29 in 138 kg 305 Ib 237158 1270 mm 50 in 864 mm 34 in 1864 mm 34 in 737 mm 29 in 148 kg 325 Ib 308415 15 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defec
19. the equipment to rupture or malfunction and result in serious injury Graco Information 0 0 0 c cee eee eee 16 Ra NA INSTRUCTIONS This equipment is for professional use only Read all instruction manuals tags and labels before operating the equipment Use the equipment only for its intended purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressure of the lowest rated system component Refer to the Technical Data on page 14 for the maximum working pressure of this equipment Use fluids and solvents which are compatible with the equipment wetted parts Refer to the Tech nical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Do not use hoses to pull equipment Route hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 82 C 180 F or below 40 C 40 F Wear hearing protection when operating this equipment Do not lift pressurized equipment Comply with all applicable local state and national fire electrical and safety regulations 2 308415 A WARNING SKIN INJECTION HAZARD Spray from the gun hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury including the need for a
20. ts in material and workmanship on the date of sale to the original purchaser for use With the exception of any special extended or limited warranty published by Graco Graco will for a period of twelve months from the date of sale repair or replace any part of the equipment determined by Graco to be defective This warranty applies only when the equipment is installed operated and maintained in accordance with Graco s written recommendations This warranty does not cover and Graco shall not be liable for general wear and tear or any malfunction damage or wear caused by faulty installation misapplication abrasion corrosion inadequate or improper maintenance negligence accident tampering or sub stitution of non Graco component parts Nor shall Graco be liable for malfunction damage or wear caused by the incompatibility of Graco equipment with structures accessories equipment or materials not supplied by Graco or the improper design manufacture installation operation or maintenance of structures accessories equipment or materials not supplied by Graco This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect If the claimed defect is verified Graco will repair or replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does n
21. ts or other goods sold hereto whether due to a breach of contract breach of warranty the negligence of Graco or otherwise FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document as well as all documents notices and legal proceedings entered into given or instituted pursuant hereto or relating directly or indirectly hereto be drawn up in English Les parties reconnais sent avoir convenu que la r daction du pr sente document sera en Anglais ainsi que tous documents avis et proc dures judiciaires ex cut s donn s ou intent s a la suite de ou en rapport directement ou indirectement avec les procedures concern es Graco Information TO PLACE AN ORDER contact your Graco distributor or call one of the following numbers to identify the distributor closest to you 1 800 328 0211 Toll Free 612 623 6921 612 378 3505 Fax All written and visual data contained in this document reflects the latest product information available at the time of publication Graco reserves the right to make changes at any time without notice This manual contains English MM 308415 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC P O BOX 1441 MINNEAPOLIS MN 55440 1441 www graco com 09 1994 Revised 01 2008 16 308415