GE 500A436P006 Clothes Dryer User Manual

image

Contents

1. AX WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE TO REGISTER YOUR DRYER CALL TOLL FREE 1 888 269 1192 Prompt registration confirms your right to protection under the terms of your warranty www GEAppliances com For Questions on Installation Call 1 800 626 2000 US or Pub 31 16225 1 800 561 3344 Canada 500A436P006 REMOVE 4 HOLE PLUGS AND PLACE THEM IN THE HOLES REMOVE 4 ON THE OPPOSITE SIDE HINGE SCREWS ROTATE DOOR 180 AND REINSTALL SERVICING AX WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING INST ALLATION For replacement parts and other information refer to Owner s Manual for servicing phone numbers
2. Location Where They Will Be Noticed By the Owner For Alcove or Closet Installation see section 9 For Bathroom or Bedroom Installation see section 10 For Mobile or Manufactured Home see section 11 Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are 0 in clearance both sides and 1 in rear Consideration must be given to provide adequate clearance for proper operation and service 1 PREPARING FOR INSTALLATION OF NEW DRYER TIP Install your dryer before installing your washer This will allow better access when installing dryer exhaust DISCONNECTING GAS TURN GAS SHUT OFF VALVE DISCONNECT AND DISCARD OLD TO THE OFF FLEXIBLE GAS CONNECTOR AND Ta POSITION A OLD TRANSITION DUCTING MATERIAL REPLACE WITH NEW CSA AGA APPROVED FLEXIBLE GAS LINE CONNECTOR AND UL APPROVED TRANSITION DUCT A WARNING NEVER REUSE OLD FLEXIBLE CONNECTORS The use of old flexible connectors can cause leaks and personal injury Always use new flexible connectors when installing gas appliances REMOVING LINT FROM WALL EXHAUST OPENING e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct INTERNAL DUCT CHECK THAT EXHAUST OPENING n HOOD DAMPER OPENS AND CLOSES FREELY TILT THE DRYER SIDEWAYS AND REMOVE THE FOAM SHIPPING PADS BY PULLING AT THE SIDES A
3. securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 e The vent MUST NOT be terminated beneath a mobile or manufactured home e The vent duct material MUST BE METAL e KIT 14 D346 33 MUST be used to attach the dryer securely to the structure e The vent MUST NOT be connected to any other duct vent or chimney s Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent e Provide an opening with a free area of at least 25 sq in or introduction of outside air into the dryer room Installation Instructions 12 DRYER EXHAUST TO LEFT OR BOTTOM CABINET A WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REMOVE SCREW AND SAVE O O REMOVE as DESIRED KNOCKOUT ONE ONLY Detach and remove the bottom or left side knockout as desired Remove the screw inside the dryer exhaust duct and save Pull the duct out of the dryer FIXING HOLE Cut the duct as shown and keep portion A TAB LOCATION BEND TAB UP 45 Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver ADDING NEW DUCT FIXING HOLE PORTION A LEFT SIDE EXHAUST Reconnect the cut portion A of the duc
4. to be 1 2 in rigid pipe and equipped with an accessible shut off within 6 ft of and in the same room with the dryer e Use pipe thread sealer compoundor Teflon tape appropriate for naturalor LP gas e You must use with this dryer a flexible metal connector listed connector ANSI Z21 24 CSA 6 10 The length of the connect shall not exceed 3 ft e Connect flexible metal connector to dryer and gas supply e Open shut off valve Installation Instructions RECONNECTING GAS Listed connector ANSI Z21 24 CSA 6 10 ADAPTER 1 8 NPT PIPE NEW METAL FLEXIBLE GAS X 3 LINE CONNECTOR a INCET PRESSURE SHUT OFF ADAPTER VALVE PIPE SIZE AT LEAST 1 2 ITEMS NOT SUPPLIED Note The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant Caution Use adapters as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES APPLY PIPE COMPOUND TO ALL MALE THREADS TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES DO NOT OVERTORQUE GAS CONNECTIONS 4 LEAK TEST AX WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS OPEN GAS VALVE Check all connections for leaks with soapy solution or equivalent Apply s
5. BLISHED GROUND 6 EXHAUST INFORMATION AX WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short 60 Feet 45 Feet 35 Feet 25 Feet EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP e Terminate in a manner to prevent back drafts or entry of birds or other wildlife e Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging e Never install a screen in or over the exhaust duct This could cause lint build up e Wall caps must be installed at least 12 in above ground level or an
6. E OR CLOSET INSTALLATION e If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back e The dryer MUST be vented to the outdoors See the EXHAUST INFORMATION section e Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear e Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in e Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed e The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line e No other fuel burning appliance shall be installed in the same closet with the dry er BATHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 6 e The installation must conform with local codes or in the absence of local codes with the NATIONAL FUEL GAS CODE ANSI Z223 11 MOBILE OR MANUFACTURED HOME INSTALLATION e Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or when such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME NO 5018 e The dryer MUST be vented to the outdoors with the termina tion
7. Installation Instructions Gas Dryer 06 If you have any questions call 1 800 GECARES US or 1 800 361 3400 Canada or Visit our Web site at www GEAppliances com BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTAN T Save these instructions for local inspector s use bs IMPORTAN T Observe all governingcodes and ordinances e Note to Installer Be sure to leave these instructions with the customer e Note to Customer Keep these instructions with your Use and Care Book for future reference e Before the old dryer is removed from service or discarded remove the dryer door e Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent e Service information and the wiring dia gram are located in the control console e Do not allow children on or in the appliance Close supervision of child ren is necessary when the appliance is used near children e Install the dryer where the temp erature is above 50 F for satisfactory operation of the dryer control system TOOLS YOU WILL NEED a gt LEVEL SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER Verify Your Gas Installation see section 2 Prepare the Area and Exhaust for Installation of New Dryer see section 1 Check and Insure the Existing External Exhaust is Clean see section 1 and Meets Attached Installation Specifications see section 6 Remove the Foam Shipping Pads see section 1
8. Move the Dryer to the Desired Location Level Your Dryer see section 8 Connect the Gas Supply see section 3 and check for leaks see section 4 AWARNING pisk or FIRE e To reduce the risk of severe injury or death follow all installation instructions e Clothes dryer installation must be performed by a qualified installer e Install the clothes dryer according to these instructions and in accordance with local codes In the absence of local codes installation must comply with National Fuel Gas Code ANSIZ223 1 NFPA 54 or the Canadian Natural Gas and Pr opane Installation Cade CSA B149 1 e California Safe Drinking Water and Toxic Enforcement Act This act requires the governor of California to publish a list of substances known to the state to cause cancer birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances Gas appliances can cause minor exposure to four of these substances namely benzene carbon monoxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Properly adjusted dryers will minimize incomplete combustion Exposure to these substances can be minimized further by properly venting the dryer to the outdoors e This dryer must be exhausted to the outdoors Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors DO NOT install a clothes dryer with flexible plastic ducting material
9. ND BREAKING THEM AWAY FROM THE DRYER LEGS BE SURE TO REMOVE ALL OF THE FOAM PIECES AROUND THE LEGS 2 GAS REQUIREMENTS A WARNING e Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve amp Burner Assem bly for use only with natural gas Using conversion kit WE2 5X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST BE MADE BY PROPERTLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCOR DANCE WITH LOCAL CODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the gas supply piping system during any pressure testing of that system at a test pressure in excess of 0 5 PSI 3 4 KPa The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0 5 PSI 3 4 KPa DRYER GAS SUPPLY CONNECTION 3 8 NPT MALE THREAD GAS SUPPLY NOTE Add to vertical dimension the distance between cabinet bottom to floor GAS SUPPLY e A 1 8 in National Pipe Taper thread plugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection to the dryer Contact your local gas utility should you have questions on the installation of the plugged tapping e Supply line is
10. TE WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING HOWEVER IF FLEXIBLE DUCTING IS USED IT MUST BE UL LISTED METAL NOT PLASTIC STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE ELBOW HIGHLY RECOMMENDED NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING LEVELING DRYER LEVEL FRONT TO BACK LEVEL SIDE TO SIDE 4 LEVELING LEGS TI TIP LEGS STAND THE DRYER UPRIGHT NEAR THE FINAL LOCATION AND ADJUST THE 4 LEVELING LEGS TO MATCH THE HEIGHT OF YOUR WASHER ADJUST THE 2 ANTI TIP LEGS TO CONTACT THE FLOOR Installation Instructions CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transitions ducts reduce the risk of crush ing and kinking ULLISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT e If rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X10077 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e For many applications installing elbows at both the dryer and the wall is highly recommended see illustra tions below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition d
11. his manual e Do not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a fire hazard e Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of grease and lint creates a potential fire hazard e Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard e Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard e Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard e Do not obstruct incoming or exhausted air e Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once a year THIS DRYER COMES READY FOR REAR EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented at floor level FOR STRAIGHT LINE INSTALLATION CONNECT THE DRYER EXHAUST TO THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP CSA AGA APPROVED NEW FLEXIBLE GAS LINE CONNECTOR GAS INLET PIPE OPENING e EXTERNAL CMe DUCT TAPE OR DUCT CLAMP NO
12. oap solution Leak test solution must not contain ammo nia which could cause damage to the brass fittings If leaks are found close valve retighten the joint and repeat the soap test Installation Instructions 5 ELECTRICAL CONNECTION INFORMATION AX WARNING TO REDUCE THE RISK OF FIRE ELECTRICALS HOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRI CAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This appliance must be supplied with 120V 60Hz and connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If electrical supply provid ed does not meet the above specifications it is recommended that a licensed electrician install an approved outlet Aa WARNING THIS DRYER IS EQUIPPED A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG ENSURE PROPER GROUND EXISTS BEFORE USE IF LOCAL CODES PE AN EXTERNAL GROU NOT PROVIDED WHICH MEETS LOCAL CODES MAY BE ADDED BY ATTACHING TO THE GREEN GROUND SCREW ON THE REAR OF THE DRYER AND TO A GROUNDED METAL COLD WATER PIPE OR OTHER ESTA
13. s If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in C onnecting The Dryer To House Vent on page 6 of this manual Flexible ducting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire Do not install or store this appliance in any location where it could be exposed to water and or weather Save these instructions Installers Be sure to leave these instructions with the customer In the state of Massachusetts installation must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the state MATERIALS YOU WILL NEED a2 pP ep 4 DIAM METAL ELBOW EXHAUSTHOOD COMPOUND soap SOLUTION DIA FLEXIBLE METAL ISEMLRIGID C PASA KEERTEN LISTED TRANSITION DUCT x2 A IF NEEDED Va SA KIT woex0077 INCLUDES 2 ELBOWS QO SAFETY GLASSES DDD 4 DIA FLEXIBLE METAL FOIL TYPE UL LISTED TRANSITION DUCT IF NEEDED 4 DIA METAL DUCT RECOMMENDED 4 DUCT CLAMPS OR 4 SPRING CLAMPS x2 DUCT TAPE COON o O K D FLEXIBLE GAS LINE CONNECTOR GLOVES Step 8 Connect the External Exhaust see section 7 Step 9 Connect the Power Supply see section 5 Step 10 Check the Operation of the Power Supply Gas Connections and Venting Step 11 Place the Owners Manual and the Installation Instructions in a
14. t to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT SIDE OF CABINET e Preassemble 4 elbow with 4 duct Wrap duct tape around joint Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct CAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct e Apply duct tape as shown on the joint between the dryer internal duct and the elbow DUCT CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard Installation Instructions 13 CHANGING DIRECTION OF DOOR OPENING ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown on page 7 CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET PLATE KIT WE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WEIM454 available from your local service provider Place dryer in final location
15. uct maximizing drying performance e Avoid resting the duct on sharp objects ULLISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT e In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foil type duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct e In Canada and the United States only the flexible metal foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e Avoid resting the duct on sharp objects e For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp ELBOW HIGHLY RECOMME DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH DO NOT CRUSH FLEXIBLE EXHAUST 9 ALCOV
16. y other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS e All joints should be tight to avoid leaks The male end of each section of duct must point away from the dryer e Do not assemble the ductwork with fasteners that extend into the duct They will serve as a collection point for lint e Duct joints can be made air and moisture tight by wrapping the overlapped joints with duct tape e Horizontal runs should slope down toward the outdoors inch per foot INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up Installation Instructions EXHAUST CONNECTION Ag WARNING TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY e This clothes dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for the home exhaust duct e Use only 4 rigid metal or UL listed flexible metal semi rigid or foil type duct to connect the dryer to the home exhaust duct It must be installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 6 of t

Download Pdf Manuals

image

Related Search

Related Contents

005 Table and Radial Arm Saw Safety  EA728GH-31 デジタルアウトドア温度計(電池式)取扱説明書  Bedienungshandbuch MVPS G3 Operating Manual  Catalogue Métal - Plafond et Mur  平成23年度衛生研究所研究課題内部評価結果報告書 1 評価  link here  Programme réunion du 27.03.08 et coupon-réponse  Home Decorators Collection 4772810410 Instructions / Assembly  Celui qui est déjà là  