2. A e
3. RAS IANA PEER o eb DP BER FAR Intel Server Chassis SC5400 Users Guide ITE ITE
4. Pu BIEZ IRE v MT 15 Vi E Intel Server Chassis SC5400 Users Guide
5. AA Intel Server Chassis SC5400 Users Guide 113 N ZE JE AAA AAA SUE A AR ar KBL AE AURA
6. A N Intel Server Chassis SC5400 Users Guide 115 116 Intel Server Chassis SC5400 User s Guide Appendix C Warranty Limited Warranty for Intel Chassis Subassembly Products Intel warrants that the Products defined herein as the Intel chassis subassembly and all of its various components and software delivered with or as part of the Products to be delivered hereunder if properly used and installed will be free from defects in material and
7. A OO000000000000 ERERSEEEEEE DOOO0000000000 OO000000000000 OOOODOOOO000000 OOCOO000000000 o o CES OOO EHBH COSA LILILILI BE debo deba LILILILI O000 LILILILI BE COSA DODO TP00526 A Fixed Power Supply B I O Ports C PCI Add in Card Slots D PCI Card Latch E Rear Serial B Connector optional F Knockout G AC Power Connector Note I O connectors vary depending on the server board installed See your server board documentation for port identification Figure 5 Server Chassis Back 10 Intel Server Chassis SC5400 User s Guide Peripheral Devices The chassis provides locations and hardware for installing hard drives a floppy drive a CD ROM drive or a DVD ROM drive The drives must be purchased separately The following figure shows the available options en eee el aa sense a Weiss penes AF000552 A Slimline floppy drive DVD ROM drive CD ROM drive B USB ports 2 C Hard drive bays Figure 6 Optional Peripherals Intel Server Chassis SC5400 User s Guide 11 Standard and Optional Hot swap Drive Bays Note One bay supporting six cabled drives ships with the standard chassis Optional hot swap drive bays may replace
8. The BSMI Certification Marking and EMC warning is located on the outside rear area of the product 76 Intel Server Chassis SC5400 User s Guide Korean Compliance RRL Following is the RRL certification information for Korea BE 249 ZH CIZHO Hays H ge H R MZF7 0 OA OD PI A ror English translation of the notice above 1 Type of Equipment Model Name On License and Product 2 Certification No On RRL certificate Obtain certificate from local Intel representative Name of Certification Recipient Intel Corporation T Date of Manufacturer Refer to date code on product Manufacturer Nation Intel Corporation Refer to country of origin marked on product CNCA CCC China The CCC Certification Marking and EMC warning is located on the outside rear area of the product A Hi of f 05145 ME Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements The following is Intel s product ecology compliance criteria Intel Server Chassis SC5400 User s Guide 77 Table 12 Product Ecology Compliance Markings Compliance Regional Description Compliance Reference Co
9. T 27 HI ESD N A icio ESD ESD ESD ESD HE SE 114 Intel Server Chassis SC5400 User s Guide A
10. A Fixed Power Supply G Hard Disk Drive Cage Release Mechanisms 2 B Rear Serial B Connector H Front Panel Controls C PCI Add in Card Panel I 5 25 inch Device Bays D Memory Air Duct J Front Panel USB Serial B E Processor Air Duct K Fixed Drive Cage 4 Drive accessory F Fixed Fans 2 L Fixed Drive Cage 6 Drive Figure 2 Internal Component Locations 6 Intel Server Chassis SC5400 User s Guide Front Control Panel The following figure shows the features available on the Front Control Panel The Intel Local Control Panel is optional TP00701 A ID Toggle Switch F NIC2 Activity LED green B Reset Button G IDLED blue C NIC 1 Activity LED green H Status LED bi color D Power Button NMiButon E Hard Drive Activity LED green Figure 3 Front Control Panel Intel Server Chassis SC5400 User s Guide 7 Descriptions of the front control panel LEDs are listed in the following table See your server documentation for functionality of buttons Table 5 Front Control Panel LED Descriptions LED Name Color Condition Description Power LED Green On Power on Off Power off Status Green On System ready Blink System ready but degraded some CPU fault DIMM killed Green Blink Blink Condition during BMC reset Amber Amber On Critical alarm critical power module failure critical fan failure
11. Intel Intel GR A FE Intel pr A Web bp EL pets i E a E EH HET JM
12. 12V X A 5 V standby X _A Total Combined Wattage Caution Do not exceed a combined power output of 170 Watts for the 5 V and 3 3 V outputs Exceeding a combined 170 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction 66 Intel Server Chassis SC5400 User s Guide Appendix B Regulatory and Compliance Information Product Regulatory Compliance Warning To ensure regulatory compliance you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold To help ensure EMC compliance with your local regional rules and regulations before computer integration make sure that the server system power supply and other modules have passed EMC testing using a server board with a microprocessor from the same family or higher and operating at the same or higher speed as the microprocessor used on this server board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel repres
13. TP00696 ing Center Divider Remov Figure 59 55 Intel Server Chassis SC5400 User s Guide 56 8 Loosen thumb screw see letter A in the following figure securing the power distribution board to the chassis Lift the power distribution board off of the standoffs see letter B and then remove it through the back of the power supply cage see letter C You may have to feed the power cables through the power supply cage while removing the power distribution board TP00698 Note Cables on back of power distribution board not shown to clarify insertion process Figure 60 Removing Power Distribution Board Intel Server Chassis SC5400 User s Guide 9 Insert new power distribution board into power supply cage see letter A in the following figure Try to route the power cables to the appropriate area at the time of insertion see Steps 9 and 10 below Position the power distribution board on the four standoffs inside the power supply cage Push down on the power distribution board to securely attach it to the standoffs see letter B Tighten thumb screw see letter C TP00693 Note Cables on back of power distribution board not shown to clarify insertion process Figure 61 Securing Power Distribution Board to Power Supply Cage 10 Connect the P1 P14 and P16 cables to the server board See the Intel server board Quick Start User s Guide or User Guide for appropriate connecti
14. Intel Server Chassis SC5400 User s Guide solar directa Alejado de fuentes de vibraci n Aislado de campos electromagn ticos fuertes producidos por dispositivos el ctricos En regiones con frecuentes tormentas el ctricas se recomienda conectar su sistema a un eliminador de sobrevoltage y desconectar el m dem de las l neas de telecomunicaci n durante las tormentas Provisto de una toma de tierra correctamente instalada Provisto de espacio suficiente como para acceder a los cables de alimentaci n ya que stos hacen de medio principal de desconexi n del sistema 125 Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell alimentazione di questo prodotto E possibile che il prodotto disponga di pi fonti di alimentazione Non modificare o utilizzare il cavo di alimentazione in c a fornito dal produttore se non corrisponde esattamente al tipo richiesto Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c a separato L interruttore attivato disattivato nel pannello anteriore non interrompe l alimentazione in c a del sistema Per interromperla necessario scollegare tutti i cavi di alimentazione in c a dalle prese a muro o dall alimentazione di corrente PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici colle
15. 60 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Remove the front bezel assembly if it is installed For instructions see Removing the Bezel Assembly Pedestal Only on page 18 Remove any PCI add in boards that are present For instructions see Removing PCI Add in Board s on page 45 Remove the processor and memory air ducts For instructions see Removing the Processor and Memory Air Ducts on page 20 If installing a server board refer to the User Guide and or Quick Start User s Guide that shipped with your Intel server board for installation instructions Use the mounting screws bumpers and standoffs if necessary that came with your chassis to secure the server board to the chassis Make sure the server board is properly seated and then tighten the screws firmly starting with the screws at the center of the server board Make cable connections per instructions in the Intel server board User Guide and or Quick Start User 5 Guide If removing a server board disconnect all cables connected to the server board Remove the mounting screws starting with the screws at the center of the server board Remove the server board Re install the processor and memory air ducts For instructions see Installing th
16. Product Regulatory Compliance Markings Compliance Regional Description Compliance Reference Compliance Reference Marking Example Russia GOST R Certification GOST R 29216 91 Emissions GOST R 50628 95 Immunity es Ukraine Ukraine Certification None Required Taiwan BSMI CNS13438 O R33025 FAIR EEE I CREAMER TERRA GLAS C MERIDA A DADA Intel Server Chassis SC5400 User s Guide Electromagnetic Compatibility Notices FCC Verification Statement USA This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions related to the EMC performance of this product contact Intel Corporation 5200 N E Elam Young Parkway Hillsboro OR 97124 6497 1 800 628 8686 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications
17. 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vietnam 632 6368416 IDD via Philippines Domestic 0120 868686 Outside country 81298 47 0800 Latin America 68 Argentina Contact AT amp T USA at 0 800 222 1288 Once connected dial 800 843 4481 Brazil 001 916 377 0180 Chile Easter Island Contact AT amp T USA at 800 800 311 Once connected dial 800 843 4481 Mainland and Juan Contact AT amp T USA at 800 225 288 Once connected dial 800 843 4481 Intel Server Chassis SC5400 User s Guide Colombia Contact AT amp T USA at 01 800 911 0010 Once connected dial 800 843 4481 Costa Rica Contact AT amp T USA at 0 800 0 114 114 Once connected dial 800 843 4481 Ecuador Andimate Contact AT amp T USA at 1 999 119 Once connected dial 800 843 4481 Pacifictel Contact AT amp T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT amp T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT amp T USA at 001 800 462 628 4240 Once connected dial 800 843 4481 Miami 1 800 621 8423 Panama Contact AT amp T USA at 00 800 001 0109 Once connected dial 800 843 4481 Paraguay 001 916 377 0114 Peru 001 916 377 0114 Uruguay 001 916 377 0114 Venezuela Contact AT amp T USA at 0 800 2255 288 Once c
18. Intel Server Chassis SC5400 User s Guide Intel Remote Management Module Note The Intel Remote Management Module is available to provide advanced system management features For installation instructions on installing the Intel Remote Management Module see the instructions provided with the module Some server boards may not support the Intel Remote Management Module See your server board documentation to determine if this feature is compatible with your server board Rack mounted Systems Your Intel Server Chassis SC5400 can be mounted into a rack Intel provides a tool less rail kit and a cable management arm to mount this server chassis into a rack When installing the chassis into a rack Intel recommends you install systems from the bottom of the rack to the top In other words install the first system in the rack into the bottom position of the rack the second system in the second position from the bottom and so on Instructions for installing your chassis into a rack are included in the rail kit The order numbers are as follows Tool less Rail Kit ARIGRACK Cable Management Arm AXXRACKCARM requires the tool less rail kit Intel Server Chassis SC5400 User s Guide 13 14 Intel Server Chassis SC5400 User s Guide 2 Hardware Installations and Upgrades Before You Begin Before working with your server product pay close attention to the Safety Information on page iii This docu
19. Observe the safety and ESD precautions at the beginning of this book 2 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 3 Press latch on fan see letter A in the following figure and pull on handle to remove hot swap fan from chassis 4 Repeat previous step for removal of remaining hot swap fans D gt ata N 9 22 AF000573 Figure 15 Removing Hot Swap Fan 24 Intel Server Chassis SC5400 User s Guide Installing Hot Swap Fans Note This procedure applies only to the Intel Server Chassis SC5400LX or SC5400LXi configurations The Intel Server Chassis SC5400 BASE and Intel Server Chassis SC5400BRP configurations ship with fixed fans The hot swap fans from the Intel Server Chassis SC5300 LX cannot be used in the Intel Server Chassis SC5400LX or SC5400LXi 1 Observe the safety and ESD precautions at the beginning of this book 2 Remove the chassis cover if not removed in a previous step For instructions see Removing the Chassis Cover on page 16 Insert the hot swap fan into the chassis until it latches into place 4 Repeat previous step for insertion of remaining hot swap fans AF000574 Figure 16 Installing Hot Swap Fan Intel Server Chassis SC5400 User s Guide 25 Installing and Removing a Slimline USB Floppy CD DVD Combo Kit Installing a Sli
20. Power Supply Specifications nn 63 670 W Single Power Supply Input Voltages ppp 63 670 W Single Power Supply Output Voltages ppp 63 830 W Single Power Input Voltages pp 63 830 W Single Power Supply Output Voltages ppp 64 System Environmental Specifications i 64 A a use 65 Calculating Power Usage is 65 Appendix A Getting Help roccia zii nia iii 67 Word Wide WED Rc e 67 e ee een ene e 67 Appendix B Regulatory and Compliance Information 71 xii Intel Server Chassis SC5400 User s Guide Product Regulatory Compliance pp 71 Product Safety Compliance iria 71 Product Regulatory Compliance References pp 72 Electromagnetic Compatibility Notices i 75 FCC Verification Statement USA nn 75 Industry Canada ICES 003 pp 76 Europe CE Declaration of Conformity pp 76 TN a ee dd 76 BSMI Taiwan see 76 Korean Compliance RRL iii 17 CNCA CECI ee ee 77 Product Ecology Compliance s ns 77 o A 80 Regulated Specified Components pp 81 End of Life Product Recycling i 82 Appendix C Warranty rc nue a ee 83 Limited Warranty for Intel Chassis Subassembly Products ce 83 Extent of Limited Warranty lealt 84 Warranty Limitations and Exclusions pp 84 Limitations ot Wo FEE ERE ER EET 84 How to Obtain Warranty Service sss nennen nnne nennen 85 Telephone Support une 85 Returning a Defec
21. Dotata di spazio sufficiente ad accedere ai cavi di alimentazione i quali rappresentano il mezzo principale di scollegamento del sistema Intel Server Chassis SC5400 User s Guide 127 128 Intel Server Chassis SC5400 User s Guide Appendix D Safety Information English Server Safety Information This document applies to Intel server boards Intel server chassis pedestal and rack mount and installed peripherals To reduce the risk of bodily injury electrical shock fire and equipment damage read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel server product In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product the product documentation takes precedence Your server should be integrated and serviced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings and Cautions To avoid personal inj
22. Ger ts vom Stromnetz Die Steckdose mu in der N he der Anlage angebracht und gut erreichbar sein Netzkabel m ssen an eine ordnungsgem geerdete Steckdose angeschlossen sein Warnhinweise f r den Systemzugang Vorsicht Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beachten Schalten Sie alle am Produkt angeschlossenen Peripherieger te aus Schalten Sie das System mit dem Netzschalter aus Trennen Sie das Ger t von der Stromquelle indem Sie alle Netzkabel vom System bzw aus der Steckdose ziehen Ziehen Sie alle Kabel und alle an das System angeschlossenen Telekommunikationsleitungen ab Bewahren Sie alle Schrauben und anderen Befestigungselemente gut auf nachdem Sie die Geh useabdeckung entfernt haben Wenn Sie Ihre Arbeiten im Systeminneren beendet haben befestigen Sie die Geh useabdeckung mit den Originalschrauben bzw befestigungselementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Schalten Sie den Server aus und ziehen Sie alle Netzkabel ab bevor Sie Komponenten ein oder ausbauen die nicht hot plug f hig sind Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen Vorsicht War Ihr Server in Betrieb k nnen die
23. Handhabung von Ger ten Beachten Sie zur Vermeidung von Verletzungen oder Besch digungen an den Ger ten die folgenden Hinweise Halten Sie beim Transportieren und Anheben von Ger ten die rtlichen Gesundheits und Sicherheitsvorschriften ein Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Ger ten 94 Intel Server Chassis SC5400 User s Guide Entfernen Sie alle Komponenten die sich leicht abnehmen lassen um das Gewicht zu reduzieren und die Handhabung zu erleichtern Warnungen zu Netzspannung und Elektrizit t Vorsicht Durch Bet tigen der mit dem Standby Symbol gekennzeichneten Netztaste wird das System NICHT vollst ndig vom Netz getrennt Es sind weiterhin 5 V aktiv solange das System eingesteckt ist Um das System vollst ndig vom Strom zu trennen mu das Netzkabel aus der Steckdose abgezogen werden Das System verf gt m glicherweise ber mehrere Netzkabel Vergewissern Sie sich in diesem Fall da alle Netzkabel abgezogen sind Wenn Sie Komponenten ein oder ausbauen m chten die nicht hot plug f hig sind stellen Sie sicher da zuvor alle Netzkabel abgezogen sind Nehmen Sie keine nderungen am Netzkabel vor und verwenden Sie kein Kabel das nicht genau dem geforderten Typ entspricht Jedes Netzteil im System mu ber ein eigenes Netzkabel angeschlossen werden Einige Netzteile von Intel Servern verwenden Nullleitersicherungen Vorsicht ist geboten i
24. Make sure all AC power cords are unplugged Make sure the AC power cord s is are unplugged before you open the chassis or add or remove any non hot plug components Do not attempt to modify or use an AC power cord if it is not the exact type required A separate AC cord is required for each system power supply Some power supplies in Intel servers use Neutral Pole Fusing To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing The power supply in this product contains no user serviceable parts Do not open the power supply Hazardous voltage current and energy levels are present inside the power supply Return to manufacturer for servicing When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing it from the server To avoid risk of electric shock turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Power Cord Warnings If an AC power cord was not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as follows Do not attempt to modify or use the AC power cord s if they are not the exact type required to fit into the grounded electrical outlets The power cord s must meet the following criteria The
25. N Indica la existencia de un riesgo que podr a causar lesiones personales o da os en la propiedad leves si no se tiene en cuenta la PRECAUCION ADVERTENCIA Indica la existencia de un riesgo que podr a causar lesiones personales graves si no se tiene en cuenta la ADVERTENCIA Indica un riesgo potencial si no se tiene en cuenta la informaci n indicada indica riesgo de descargas el ctricas que podr an causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad Indica componentes o superficies calientes indica que no se deben tocar las aspas de los ventiladores ya que de lo contrario se podr an producir lesiones spp Intel Server Chassis SC5400 User s Guide 105 Indica que es necesario desenchufar los cables de alimentacion de CA para Saas desconectar la alimentaci n de CA x Recicle por favor la bateria ES Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnolog a inform tica ITE que puede instalarse en oficinas escuelas salas de equipos inform ticos o lugares de mbito comercial similares Es posible que sea necesario llevar a cabo una evaluaci n adicional para comprobar si este producto es apropiado para otras categor as de productos y entornos adem s de las aplicaciones inform ticas por ejemplo soluciones m dicas industriales residenciales sistemas de alarma y equipos de pruebas Selecci n de la ubicaci n El si
26. Server Chassis SC5400 User s Guide Afin de permettre le refroidissement et l a ration du systeme r installez toujours les panneaux du boitier avant de mettre le syst me sous tension Le fonctionnement du syst me en l absence des panneaux risque d endommager ses pi ces Pour installer les panneaux proc dez comme suit 1 Assurez vous de ne pas avoir oubli d outils ou de pieces d mont es dans le systeme 2 Assurez vous que les c bles les cartes d extension et les autres composants sont bien install s 3 Revissez solidement les panneaux du bo tier avec les vis retir es plus t t 4 Remettez le cadenas en place et verrouillez le afin de pr venir tout acces non autoris a l int rieur du systeme 5 Rebranchez tous les cordons d alimentation c a et c bles externes au systeme Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le systeme a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le fabricant Disposez des piles us es selon les instructions du fabricant Le systeme a t concu pour fonctionner dans un cadre de travail normal L emplacement choisi doit tre LE A Propre et d pourv
27. Wide Web http support intel com support motherboards server SC5400 Telephone All calls are billed US 25 00 per incident levied in local currency at the applicable credit card exchange rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice Before calling fill out an Intel Server Issue Report Form available from the Web at http support intel com support motherboards server SC5400 For the fastest service submit your form via the Internet For an updated support contact list see http www intel com support 9089 htm U S and Canada 1 800 404 2284 Europe Belgium 02 714 3182 Denmark 38 487077 Finland 9 693 79297 France 01 41 918529 Germany 069 9509 6099 Holland 020 487 4562 Italy 02 696 33276 Norway 23 1620 50 Spain 91 377 8166 Sweden 08 445 1251 UR sci 870 6072439 Intel Server Chassis SC5400 User s Guide 67 In Asia Pacific Region Japan Australia 1800 649931 Cambodia 63 2 636 9797 via Philippines China 800 820 1100 toll free EE 8 621 33104691 not toll free Hong Kong 852 2 844 4456 India 0006517 2 68303634 manual toll free You need an IDD equipped telephone Indonesia 803 65 7249 Korea 822 767 2595 Malaysia 1 800 80 1390 Myanmar 63 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan
28. all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet 1 2 3 10 11 12 13 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 Press the latch at the back of the control panel Slide the control panel out through the front of the chassis far enough so that you can reach the front panel and USB cable connectors at the rear of the control panel Disconnect cables Install the control panel module into the chassis Reconnect cables Optional Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Intel Server Chassis SC5400 User s Guide 59 Installing and or Removing a Server Board Note The server board you can install in your chassis depends upon the chassis model To install or remove a server board do the following 1 2 3 10 11 12 13 14
29. bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Gehause ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf ordnungsgem en Sitz und Installation 3 Bringen Sie die Abdeckungen wieder am Geh use an indem Sie die zuvor gel sten Schrauben wieder anbringen Ziehen Sie diese gut an 4 Bringen Sie die Verschlu einrichtung Padlock wieder an und schlie en Sie diese um ein unerlaubtes Offnen des Systems zu verhindern 5 Schlie en Sie alle externen Kabel und den AC Stromanschlu stecker Ihres Systems wieder an Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist Au erdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr Die Batterie darf nur durch denselben oder einen entsprechenden vom Hersteller empfohlen
30. bs Do 2 3 AGD B p mo TP00906 Figure 30 Removing Six drive Fixed Drive Cage from Chassis Intel amp Server Chassis SC5400 User s Guide 35 6 Loosen the captive screw see letter A in the following figure Open the upper door see letter B AF000579 Figure 31 Unlocking and Opening Upper Door of Fixed Drive Cage 7 Open the lower door o SR RR post AF000580 Figure 32 Opening Lower Door of Fixed Drive Cage Intel amp Server Chassis SC5400 User s Guide 8 Remove a pair of device slides from the drive cage TI ZN NS ER SS Y o RO re S 55 AF000581 Figure 33 Removing Slides from Drive Cage 9 Attach the device slides to the hard drive This is a tool less operation Insert pins on device slides into mounting holes on hard drive Press firmly to secure device slides to hard drive Ensure that the metal tabs on the device slides are facing the front of the hard drive and facing towards each other AF000582 Figure 34 Attaching Device Slides to Hard Drive Intel Server Chassis SC5400 User s Guide 37 10 Insert the drive slide assembly into the drive cage Make sure the cable connector end of the hard drive faces towards the rear of the drive cage SIR ID OS SS SITES S ao AF000583 Figure 35 Inserting Drive Slide Assembly into Drive Cage 11 Repeat above steps for installation of additional hard drives
31. de le retirer du serveur Pour viter tout risque d lectrocution mettez le systeme hors tension et d branchez les cordons d alimentation ainsi que les syst mes de t l communication r seaux et modems reli s au syst me avant d ouvrir ce dernier Avertissements sur le cordon d alimentation Si aucun cordon d alimentation secteur n a t fourni avec votre produit vous devez vous en procurer un qui soit approuv pour une utilisation dans votre pays Attention Pour viter tout risque d lectrocution ou d incendie v rifiez les cordons d alimentation qui seront utilis s avec le produit comme suit N essayez pas d utiliser ou de modifier les cordons d alimentation en CA s ils ne correspondent pas exactement au type requis pour les prises lectriques reli es la terre Les cordons d alimentation doivent r pondre aux crit res suivants Lecordon d alimentation doit supporter une intensit sup rieure celle indiqu e sur le produit Lecordon d alimentation doit poss der une broche ou un contact de mise la terre appropri la prise lectrique Les cordons d alimentation lectrique repr sentent le principal dispositif de d connexion raccord l alimentation secteur Les prises de courant doivent se trouver proximit de l quipement et tre facilement accessibles pour une d connexion Les cordons d alimentation doivent tre branch s sur des prises lectriques correctement reli e
32. des Gebl ses zu Verletzungen f hren kann Bedeutet alle Netzkabel abzuziehen und das Ger t von der Netzspannung zu t ra rennen Bereiten Sie bitte Batterie auf Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT Ger t getestet das in Biiros Schulen Computerr umen und hnlichen ffentlichen R umlichkeiten installiert werden kann Die Eignung dieses Produkts fiir andere Einsatzbereiche als IT z B Medizin Industrie Alarmsysteme oder Pr fger te kann u U weitere Tests erfordern Standortauswahl Das System ist f r den Betrieb innerhalb normaler B roumgebungen geeignet W hlen Sie einen Standort der folgenden Kriterien entspricht Sauber trocken und frei von Partikeln in der Luft au er dem normalen Raumstaub Gut bel ftet nicht in der N he von Warmequellen und keiner direkten Sonnenbestrahlung ausgesetzt Nicht in der N he von Vibrations oder Ersch tterungsquellen e Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz anschlie en und bei einem Gewitter die Telekommunikationskabel zum Modem abziehen Eine ordnungsgem geerdete Wandsteckdose mu vorhanden sein Ausreichender Freiraum f r den Zugang zu den Netzkabeln da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind
33. ejecutando los procesadores y disipadores de calor estar n recalentados no ser que est instalando o extrayendo un componente de conexi n en funcionamiento deje que el sistema se enfr e antes de abrir las cubiertas Para que no llegue a tocar los componentes que est n calientes cuando est realizando una instalaci n de conexi n en funcionamiento tenga cuidado al extraer o instalar los componentes de conexi n en funcionamiento Precauci n Para evitar posibles da os no toque las aspas en movimiento de los ventiladores Si el sistema se le ha suministrado con una protecci n para el ventilador aseg rese de que cuando est funcionando el sistema la protecci n est en su sitio Advertencias sobre el montaje en bastidor 108 El bastidor del equipo se debe sujetar con un soporte fijo para evitar que se caiga cuando se extraiga un servidor o una pieza del mismo El bastidor del equipo debe instalarse siguiendo las instrucciones del fabricante del bastidor Instale el equipo en el bastidor comenzando desde la parte de abajo con el equipo m s pesado en la parte inferior del bastidor Intel Server Chassis SC5400 User s Guide Extraiga las piezas del equipo del bastidor de una a una El usuario es el responsable de la instalaci n de un dispositivo de desconexion de la alimentaci n principal para toda la unidad del bastidor El acceso a este dispositivo de desconexion deber ser de facil acceso y deber n incluirse ind
34. in diesem Handbuch sowie die Montageanleitungen in den Serverhandb chern zu beachten Verwenden Sie nur die beschriebenen zugelassenen Komponenten die im vorliegenden Handbuch angegeben werden Die Verwendung anderer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten Sicherheitshinweise und Vorsichtsma nahmen Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor dem Beginn der Produktinstallation die nachfolgend aufgef hrten Sicherheitshinweise und informationen sorgf ltig lesen und befolgen In dem vorliegenden Handbuch sowie auf dem Produkt und auf der Verpackung werden folgende Sicherheitssymbole verwendet Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung des VORSICHTSHINWEISES zu leichteren Verletzungen bzw Sachbesch digungen f hren kann WARNUNG Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung der WARNUNG zu ernsten Verletzungen f hren kann Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin Weist auf die Gefahr eines Stromschlags hin der bei Nichtbeachtung der A Sicherheitshinweise zu schweren oder t dlichen Verletzungen f hren kann Weist auf Verbrennungsgefahr an hei en Bauteilen bzw Oberfl chen hin Intel Server Chassis SC5400 User s Guide 93 Weist darauf hin da das Anfassen
35. installierten Prozessoren und K hlk rper hei sein Sofern Sie keine Hot Plug Komponenten ein oder ausbauen warten Sie mit dem Abnehmen der Abdeckungen bis das System abgek hlt ist Gehen Sie beim Aus oder 96 Intel Server Chassis SC5400 User s Guide Einbauen von Hot Plug Komponenten sorgf ltig vor um nicht mit hei en Komponenten in Ber hrung zu kommen Vorsicht Ber hren Sie nicht die rotierenden L fterfl gel um Verletzungen zu vermeiden Falls Ihr System mit eine L fterabdeckung besitzt darf es nicht ohne diese Abdeckung betrieben werden Warnhinweise f r Racks Das Ger te Rack mu auf einer geeigneten festen Unterlage verankert werden um ein Umkippen zu vermeiden wenn ein Server oder andere Ger te herausgezogen werden Bei der Installation des Racks m ssen die Anweisungen des Rack Herstellers beachtet werden Gehen Sie bei der Installation von Ger ten im Rack immer von unten nach oben vor und bauen Sie das schwerste Ger t an der untersten Position im Rack ein Ziehen Sie jeweils immer nur ein Ger t aus dem Rack heraus Sie m ssen f r die gesamte Rack Einheit einen Netztrennschalter einrichten Dieser Netztrennschalter mu leicht zug nglich sein und ber eine Kennzeichnung verf gen die besagt da er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den Servern Zur Vermeidung von Stromschlaggefahr m ssen das Rack selbst und alle darin eingebauten Ger te ordnungsgem geerdet se
36. letter B AF000602 Figure 53 Removing Power Supply Filler Panel 2 Insert the power supply module until it clicks into place Secure with screw see letter A in the following figure if shipping chassis to another location AF000603 Figure 54 Installing Additional Hot Swap Power Supply Module Intel Server Chassis SC5400 User s Guide 51 Replacing a Hot Swap Power Supply Warning Hazardous voltage current and energy levels are present inside the power supply There are no user serviceable parts inside it servicing should be done by technically qualified personnel 1 Remove the power cable from the defective hot swap power supply 2 If present remove shipping screw securing defective hot swap power supply to chassis see letter A in the following figure Press on green latch see letter B while pulling on handle to remove power supply from chassis AF000956 Figure 55 Removing Hot Swap Power Supply from Chassis 3 Insert new hot swap power supply into chassis Replace shipping screw see letter A in the following figure if shipping chassis to another location AF000603 Figure 56 Installing Hot Swap Power Supply into Chassis 4 Connect power cable to replaced power supply 52 Intel Server Chassis SC5400 User s Guide Replacing a Fixed Power Supply Warning Hazardous voltage current and energy levels are present inside the power supply There are no u
37. marcha el sistema Si pone en funcionamiento el sistema sin las tapas bien colocadas puede da ar los componentes del sistema Para instalar las tapas 1 Aseg rese primero de no haber dejado herramientas o componentes sueltos dentro del sistema Compruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente Incorpore las tapas al chasis mediante los tornillos extra dos anteriormente tens ndolos firmemente Inserte el bloqueo de seguridad en el sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar a n calientes Tambi n conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se cambia de forma adecuada Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo Para deshacerse de las pilas usadas siga igualmente las instrucciones del fabricante El sistema est dise ado para funcionar en un entorno de trabajo normal Escoja un lugar normal Bien ventilado y alejado de fuentes de calor incluida la luz LE Limpio y libre de part culas en suspensi n salvo el polvo
38. power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product The power cord must have safety ground pin or contact that is suitable for the electrical outlet The power supply cord s is are the main disconnect device to AC power The socket outlet s must be near the equipment and readily accessible for disconnection The power supply cord s must be plugged into socket outlet s that is are provided with a suitable earth ground Intel Server Chassis SC5400 User s Guide 89 System Access Warnings Caution Caution Caution To avoid personal injury or property damage the following safety instructions apply whenever accessing the inside of the product Turn off all peripheral devices connected to this product Turn off the system by pressing the power button to off Disconnect the AC power by unplugging all AC power cords from the system or wall outlet e Disconnect all cables and telecommunication lines that are connected to the system e Retain all screws or other fasteners when removing access cover s Upon completion of accessing inside the product refasten access cover with original screws or fasteners Do not access the inside of the power supply There are no serviceable parts in the power supply Return to manufacturer for servicing Power down the server and disconnect all power cords before adding or replacing any non ho
39. risques de dommages corporels d lectrocution d incendie et de dommages mat riels lisez ce document et respectez tous les avertissements et pr cautions mentionn s dans ce guide avant d installer ou de mettre a jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livr es avec le produit ou publi es sur le site Web pour un produit particulier la documentation du produit prime Votre serveur doit tre int gr et entretenu uniquement par des techniciens qualifi s Vous devez suivre les informations de ce guide et les instructions d assemblage des manuels de serveur pour v rifier et maintenir la conformit avec les certifications et approbations de produit existantes Utilisez uniquement les composants d crits et r glement s sp cifi s dans ce guide L utilisation d autres produits composants annulera la liste UL et les autres approbations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde Pour viter de vous blesser ou d endommager votre quipement lisez et respectez toutes les informations et consignes de s curit avant de commencer l installation du produit Les symboles de s curit suivants peuvent tre utilis s tout au long de cette documentation et peuvent figurer sur le produit ou sur son emballage ATTENTIO
40. s Guide 61 62 Intel Server Chassis SC5400 User s Guide 3 Technical Reference Power Supply Specifications 670 W Single Power Supply Input Voltages 100 127V at 50 60 Hz 12A max e 200 240V at 50 60 Hz 7A max 670 W Single Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage Ensure that your loads do not exceed the combined total wattage of 670 Watts For information about calculating the power usage for your configuration see Calculating Power Usage on page 65 Table 6 670 W Power Supply Output Capability Voltage Maximum Current 3 3 V 24 A 5 0 V 30 A 5 V Standby 3A 12 0 48 A 12 0 V 0 5 A Warning Do not exceed a combined power output of 170 Watts for the 5 V and 3 3 V outputs Exceeding a combined 170 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction The expansion slots on the server board are rated for no more than 25 Watts for any one slot The average current usage per slot should not exceed 13 Watts 830 W Single Power Input Voltages e 100 127 V at 50 60 Hz 14 A max e 200 240 V at 50 60 Hz 8 A max Intel Server Chassis SC5400 User s Guide 63 830 W Single Power Supply Output Voltages The following table lists the total wattage available from the power subsystem for each voltage If you configure your system heavily ensure that
41. securite Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel Server Deployment Toolkit CD ou bien rendez vous sur le site http support intel com support motherboards server sb cs 010770 htm Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precauci n de este documento antes de realizar cualquiera de las instrucciones Vea Intel Server Boards and Server Chassis Safety Information en el Intel Server Deployment Toolkit CD y o en http support intel com support motherboards server sb cs 010770 htm ii Intel Server Chassis SC5400 User s Guide EDITE SS BG XEPPREUEILEGGHEAI ERU FE http support intel com support motherboards server sb cs 010770 htm Eg Intel Server Boards and Server Chassis Safety Information f Intel BUS HER SISMI o Warnings Heed safety instructions Before working with your server product whether you are using this guide or any other resource as a reference pay close attention to the safety instructions You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulat
42. voltage power supply voltage and thermal fault Blink Non critical failure redundant fan failure redundant power failure non critical power and voltage Off System not ready POST error NMI event PCI or terminator missing Hard drive Green Blink Hard drive activity activity NIC1 activity Green On Linked Blink LAN activity Off Idle NIC2 activity Green On Linked Blink LAN activity Off Idle ID LED rack Blue Blink Server identification toggled by ID button or only software Off Server identification toggled by ID button or software Intel Server Chassis SC5400 User s Guide Intel Local Control Panel The following figure shows the features available on the Intel Local Control Panel The Intel Local Control Panel is optional Note The Intel Local Control Panel requires the installation of the Intel Remote Management Module See your server board documentation to determine if this control panel is compatible with your server board A moon L3 AF000955 Callout Function LCD display variable content LCD up navigation button LCD down navigation button LCD backup level navigation button m ojos LCD command enter button Figure 4 Intel Local Control Panel Features Intel Server Chassis SC5400 User s Guide Back Panel Features
43. your loads do not exceed the combined total wattage of 800 Watts For information about calculating the power usage for your configuration see Calculating Power Usage on page 65 Table 7 830 W Power Supply Output Capability Voltage Maximum Current 3 3 V 25A 5 0 V 33 A 5 V Standby 3A 12 0 51A 120V 0 5A Warning Do not exceed a combined power output of 170 Watts for the 5 V and 3 3 V outputs Exceeding a combined 170 Watts will overload the power subsystem and may cause the power supplies to overheat and malfunction The expansion slots on the server board are rated for no more than 25 Watts for any one slot The average current usage per slot should not exceed 13 Watts System Environmental Specifications Table 8 Environmental Specifications Non operating 40 to 70 C Temperature Operating 10 to 35 C derated 0 5 C for every 1000 ft 305 m to a maximum of 10 000 ft Humidity Non operating 90 relative humidity non condensing at 30 C Operating 2 0 g 11 msec 1 2 sine Shock Packaged Operational after an 18 free fall Acoustic noise UP DP BRP configurations 5 5 BA LWA idle 6 0 BA LWA typical operating Electrostatic discharge ESD Tested to 15 kilovolts kV no component damage 64 Intel Server Chassis SC5400 User s Guide Current Usage Calculating Power Usage The total combined wattage for your configuration must b
44. your server board has only one processor installed leave the inner air baffle in place and proceed to step two AF000323 Figure 12 Removing Inner Plastic Air Baffle from Processor Air Duct 2 Install the processor air duct Make sure the tabs on the processor air duct see letters A and B in the following figure engage their matching slots on the chassis before inserting tabs into the chassis slots 3 Install the memory air duct next by holding the large tab end of the memory air duct at a downward angle and then inserting the large tab see letter C from the underside into the matching slot on the processor air duct Intel Server Chassis SC5400 User s Guide 21 22 4 Rotate the memory air duct downward until the two small tabs see letter D engage and the memory air duct latch see letter E snaps into place AF000325 Figure 13 Installing the Processor and Memory Air Ducts Caution The processor air duct interlocks with the memory air duct in two places before latching into place Note Use care to avoid pinching the cables Intel Server Chassis SC5400 User s Guide Replacing a Fixed Fan Intel Server Chassis SC5400Base SC5400BRP only Note This procedure applies only to the Intel Server Chassis SC5400 BASE and Intel Server Chassis SC5400BRP configurations The Intel Server Chassis SC5400LX and SC5400LXi ship with hot swap fans 1 Obse
45. 0 Intel Server Chassis SC5400 User s Guide Alimentation et avertissements en matiere d electricite Attention Le bouton d alimentation indiqu par le symbole de mise en veille NE COUPE PAS completement l alimentation secteur du systeme car le courant de veille 5 V reste actif lorsque le systeme est sous tension Pour couper l alimentation du systeme vous devez debrancher le cordon d alimentation secteur de la prise murale Votre systeme peut utiliser plusieurs cordons d alimentation secteur Assurez vous que tous les cordons d alimentation sont debranches Vous devez les d brancher avant d ouvrir le chassis d ajouter ou de supprimer un composant non connectable a chaud Les alimentations de certains serveurs Intel sont munies de doubles fusibles p le neutre veuillez observer les pr cautions d usage afin d viter tout risque d el ctrocution N essayez pas de modifier ou d utiliser un cordon d alimentation secteur s il ne s agit pas du type exact requis Un cordon secteur est requis pour chaque alimentation syst me Le bloc d alimentation de ce produit ne contient aucun composant r parable par l utilisateur N ouvrez pas le bloc d alimentation L int rieur de celui ci est soumis des niveaux dangereux de tension de courant et d nergie Renvoyez le au fabricant en cas de probl me Lorsque vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant
46. 6 P7 P8 P9 P10 and P11 power cables standard SAS SATA route as appropriate e P12 and P13 power cables SATA route as appropriate 40 Intel Server Chassis SC5400 User s Guide Routing Data Cables to Fixed Drives Note Front panel USB and one IDE cable are pre routed by the factory SAS or SATA cables are supplied with the server board and hot swap drive accessory kits No cables are supplied with the fixed drive bay kit Route SAS SATA data cables through the chassis openings located near the bottom of the drive cage Connect data cables to the respective fixed drive and to the appropriate connector on the server board SAS SATA Cable Routin Dl Chassis Primary Side View SAS SATA i To 4 Drive Cag de IDE USB Front Panel Cables 4 6 Drive Bay Cables t Chassis Primary Side View 1 WII DTE T GO AN To 6 Drive Cage AF000509 Figure 40 Routing SAS SATA Data Cables Intel Server Chassis SC5400 User s Guide 41 Removing and Installing Hot Swap Drive s Removing Hot Swap Drive s 1 Rotate the black lever downwards to unlatch the drive carrier With the black lever open remove the drive carrier from the drive cage AF000593 Figure 41 Releasing Drive Carrier from Hot Swap Cage 2 Remove the four screws securing the hard driv
47. 60950 UL 60950 Safety U Canada USA Industry Canada CANADA ICES 003 CLASS A ICES 003 Emissions CANADA NMB 003 CLASSE A FCC This device complies with Part 15 ofthe FCC Rules Operation f this device is subject to the following tw ditions CFR 47 Part 15 1 This device may not cause harmful interference and Emissions 2 This device must accept any interference received including interference that may cause undesired operation Manufactured by Intel Corporation China CNCA CB4943 72 Safety GB 9254 Emissions GB17625 Harmonics Intel Server Chassis SC5400 User s Guide Table 11 Product Regulatory Compliance Markings Compliance Regional Compliance Description Reference Compliance Reference Marking Example CENELEC Europe Low Voltage Directive 93 68 EEC EMC Directive 89 336 EEC EN55022 Emissions EN55024 Immunity EN61000 3 2 Harmonics EN61000 3 3 Voltage Flicker CE Declaration of Conformity CE Germany GS Certification EN60950 ia International CB Certification IEC60950 CISPR 22 CISPR 24 None Required Japan VCCI Certification IRRIZ 235 a RE BT Coles ERA T i WE 2 2 EE BE Se I CEMBOET I NMF wa AED EIT S MEE m Se du RESTES CERDO ET VOCLA Korea RRL Certification MIC Notice No 1997 41 EMC amp 1997 42 EMI c2 BNS CPU Intel Server Chassis SC5400 User s Guide 74 Table 11
48. Dispose of used batteries according to manufacturer s instructions The system is designed to operate in a typical office environment Choose a site that is Clean and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight e Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect 118 Intel Server Chassis SC5400 User s Guide Deutsch Benutzer k nnen am Netzger t dieses Produkts keine Reparaturen vornehmen Das Produkt enth lt m glicherweise mehrere Netzger te Wartungsarbeiten m ssen von qualifizierten Technikern ausgef hrt werden Versuchen Sie nicht das mitgelieferte Netzkabel zu ndern oder zu verwenden wenn es sich nicht genau um den erforderlichen Typ handelt Ein Produkt mit mehreren Netzger ten hat f r jedes Netzger t ein eigenes Netzkabel Der Wechselstrom des Systems wird durch den Ein Aus Schalter f r Gleichstrom nicht ausgeschaltet Ziehen Sie jedes Wechsels
49. However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment The customer is responsible for ensuring compliance of the modified product Only peripherals computer input output devices terminals printers etc that comply with FCC Class A or B limits may be attached to this computer product Operation with noncompliant peripherals is likely to result in interference to radio and TV reception All cables used to connect to peripherals must be shielded and grounded Operation with cables connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception Intel Server Chassis SC5400 User s Guide 75 Industry Canada ICES 003 Cet appareil num rique respecte les limites bruits radio lectriqu
50. Intel Server Chassis SC5400 Intel Server Chassis SC5400 User s Guide Table 1 summarizes the features of the Intel Server Chassis SC5400 Base SKU Table 1 Server Chassis Features BASE SKU Feature Description Dimensions 16 6 inches high Pedestal 17 inches 8 6 inches wide 27 4 inches deep Pedestal 28 4 inches 34 6 kilograms Hard Drives One fixed drive bay for up to six fixed SAS or SATA drives Optional hot swap drive bays Six drive SAS SATA e Four drive SAS SATA An optional four drive fixed drive bay is also available Supports up to six drives depending on peripheral choices Peripherals Three multi mount 5 25 peripheral bays Control Panel dependent on option selected Front Control Panel Intel Local Control Panel optional LEDs and displays dependent on option selected With Front Control Panel NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity Power Supply One fixed 670 W power supply with an integrated cooling fan Upgradable to 830 W redundant power supplies Fans Two fixed non redundant chassis fans e One 120 mm fan One 92 mm fan Upgradable to redundant USB 2 0 Two front panel USB ports with Front Control Panel Four back panel USB ports depending on server board Video One rear panel video port NOTE The 12V 6 pin power connector is for the 150 W
51. Intel Server Chassis SC5400 User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D38435 005 Disclaimer Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that choo
52. Intel Server Chassis SC5400 User s Guide DI see Ea oa ee Cana ret PT 3 3 TP00906 Figure 22 Removing Six drive Fixed Drive Cage from Chassis 8 Loosen the thumb screw see letter A in the following figure Open the upper door of the drive cage see letter B AF000579 Figure 23 Unlocking and Opening Upper Door of Fixed Drive Cage Intel Server Chassis SC5400 User s Guide 31 32 9 Open the lower door AF000946 Figure 24 Opening Lower Door of Fixed Drive Cage 10 Remove the drive slide assembly from the drive cage AF000588 Figure 25 Removing Drive Slide Assembly from Drive Cage Intel Server Chassis SC5400 User s Guide 11 Remove the device slides from hard drive If not replacing hard drive insert empty device slides into drive cage AF000947 Figure 26 Inserting Empty Device Slides into Drive Cage 12 Close the lower door of drive cage ZO SET SS AF000948 Figure 27 Closing Lower Door of Fixed Drive Cage Intel Server Chassis SC5400 User s Guide 33 34 13 14 15 16 17 18 19 20 Close the upper door a SEHR IDO AF000949 Figure 28 Closing Upper Door of Fixed Drive Cage Tighten the captive screw AF000586 Figure 29 Tightening Thumb Screw Reinstall fixed hard drive into chassis If other hard drives remain in the drive cag
53. N Indique la presence d un risque pouvant entrainer des blessures physiques mineures ou endommager l g rement le mat riel si la mise en garde n est pas prise en compte AVERTISSEMENT Indique la pr sence d un risque pouvant entra ner des blessures corporelles graves si l avertissement n est pas pris en compte Indique un risque potentiel si les informations signal es ne sont pas prises en compte Indique des risques d lectrocution pouvant entrainer des blessures t corporelles graves ou mortelles si les consignes de s curit ne sont pas respect es Indique de ne pas toucher aux pales de ventilateur car cela peut entrainer des amp blessures Ignale des composants ou des surfaces soumis a des temperatures elevees Intel Server Chassis SC5400 User s Guide 99 Indique de d brancher tous les cordons d alimentation secteur pour tata d connecter l alimentation a Veuillez r utiliser la batterie ES Domaines d utilisation pr vus Ce produit a t test comme quipement informatique ITE et peut tre install dans des bureaux des coles des salles informatiques et des endroits commerciaux similaires L utilisation du pr sent produit dans des cat gories et environnements de produits et domaines d application par exemple le domaine m dical industriel r sidentiel les syst mes d alarme et les appareils de contr le autres qu ITE doit faire l objet d v
54. PCle video cards which require an external 75 W power connector Intel Server Chassis SC5400 User s Guide Table 2 summarizes the features of the BRP SKU Table 2 Server Chassis Features BRP SKU Feature Description Dimensions 16 6 inches high Pedestal 17 inches 8 6 inches wide 27 4 inches deep Pedestal 28 4 inches o 36 2 kilograms Hard Drives One fixed drive bay for up to six fixed SAS or SATA drives Optional hot swap drive bays Six drive SAS SATA Four drive SAS SATA An optional four drive fixed drive bay is also available Supports up to ten drives Peripherals Three multi mount 5 25 inch peripheral bays Control Panel dependent Front Control Panel on option selected Intel Local Control Panel optional LEDs and displays With Front Control Panel dependent on option selected e NIC1 Activity NIC2 Activity e Power Sleep System Status System Identification e Hard Drive Activity Power Supply One 830 W power supply is standard Upgradable to 830 W redundant power supplies Fans Two fixed non redundant chassis fans One 120 mm fan One 92 mm fan Upgradable to redundant USB 2 0 Two front panel USB ports with Front Control Panel Four back panel USB ports Video One front panel video port available only with Front Control Panel One rear panel video port Intel Server Chassis SC5400 User s Guide Table 3 su
55. Record the type and serial number of the add in board in your equipment log Set the jumpers or switches on the board according to the manufacturer s instructions 48 Intel Server Chassis SC5400 User s Guide 7 Hold the PCI add in board by its top edge or upper corners Firmly press the add in board into an expansion slot on the server board see letter A in the following figure Close the back panel PCI add in card retention device see letter B AF000599 Figure 51 Installing Add in Board 8 Repeat steps 2 10 until all the PCI add in cards are installed Intel Server Chassis SC5400 User s Guide 49 9 Reinstall the PCI Add in Card Retainer AF000600 Figure 52 Reinstalling PCI Add in Card Retainer 10 Attach cables if necessary 11 Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 12 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 13 Plug all peripheral devices and the AC power cable into the server 14 Power up the server 50 Intel Server Chassis SC5400 User s Guide Installing Additional Hot Swap Power Supply Module Caution This step only applies to a chassis with redundant power supply capability Do not perform this step if your chassis has a fixed power supply 1 Remove screws see letter A in the following figure Remove the power supply filler panel see
56. SD pp 103 AUS EE 103 Informaci n de seguridad del servidor nns 105 Advertencias y precauciones sobre seguridad ppp 105 Aplicaciones y usos previstos zen ee 106 Selecci n de la ubicaci n alii 106 Manipulaci n del equipo zu nee ee an 106 Advertencias de alimentaci n y el ctricas 107 Advertencias el acceso al sistema i 108 Advertencias sobre el montaje en bastidor pp 108 Descarga electrost tica ESD nn 109 Appendix E Installation Assembly Safety Instructions 117 PEN He 117 RET RR LET 119 AP E 122 ESPA O mii oda 124 GEE a 126 xiv Intel Server Chassis SC5400 User s Guide List of Figures Figure 1 Intel Server Chassis SC5400 0 1 Figure 2 Internal Component Locations pp 6 Figure 3 Front Control PENE ee nu 7 Figure 4 Intel Local Control Panel Features 9 Figure 5 Server Chassis BAC iii ii 10 Figure 6 Optional PEPPER acaso pis 11 Figure 7 Removing the Chassis COver ss 16 Figure 8 Installing the Chassis Cover inca 17 Figure 9 Removing the Front BEzel se 18 Figure 10 Installing the Front Bezel ua he epos SEU RE EUER HER dE 19 Figure 11 Removing the Processor and Memory Air Ducts pp 20 Figure 12 Removing Inner Plastic Air Baffle from Processor Air Duct sss 21 Figure 13 Installing the Processor and Mem
57. Xi SKU Feature Description Dimensions 16 6 inches high Pedestal 17 inches 8 6 inches wide 27 4 inches deep Pedestal 28 4 inches e 36 2 kilograms Hard Drives One fixed drive bay for up to six fixed SAS or SATA drives Optional expanded or non expanded hot swap drive bays Six drive SAS SATA Four drive SAS SATA An optional four drive fixed drive bay is available Supports up to ten drives Peripherals Three multi mount 5 25 inch peripheral bays Control Panel dependent Front Control Panel on option selected Intel Local Control Panel optional LEDs and displays With Front Control Panel dependent on option DE selected NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity Power Supply One redundant capable 830 W power supply module with an integrated cooling fan Optional second redundant power supply module is available Fans Four hot swap redundant chassis fans Two 120 mm fans Two 92 mm fans USB 2 0 Two front panel USB ports with Front Control Panel Four back panel USB ports Video One front panel video port available only with Standard Control Panel One rear panel video port Intel Server Chassis SC5400 User s Guide Component Identification Internal Components ongansanzhh Boonen na AF000511
58. all s peuvent tre chauds A moins que vous n ajoutiez ou ne retiriez un composant connectable chaud laissez le syst me refroidir avant d ouvrir les panneaux Pour viter tout risque d entrer en contact avec un composant chaud lors d une installation chaud prenez toutes les pr cautions n cessaires lorsque vous retirez ou installez des composants connectables chaud Attention Pour viter de vous blesser ne touchez pas les pales de ventilateur en mouvement Si votre systeme est fourni avec une protection sur le ventilateur ne mettez pas le syst me en route sans la protection en place Avertissements sur le montage en rack 102 Le rack doit tre fix un support inamovible pour viter qu il ne bascule lors de l extension d un serveur ou d un l ment de l quipement Le rack doit tre install conform ment aux instructions du fabricant Installez les quipements dans le rack en partant du bas en placant le plus lourd en bas du rack N tendez qu un seul l ment de l quipement partir du rack la fois Vous tes responsable de l installation d un disjoncteur principal d alimentation pour la totalit du rack Ce disjoncteur principal doit tre rapidement accessible et doit tre tiquet comme contr lant toute l unit et pas uniquement le ou les serveurs Intel Server Chassis SC5400 User s Guide Pour viter tout risque d lectrocution le rack et chaque l ment de l quipement i
59. aluations suppl mentaires Selection d un emplacement Le syst me est congu pour fonctionner dans un environnement standard de bureau Choisissez un emplacement respectant les conditions suivantes Propre sec et exempt de particules en suspension autres que la poussi re normale d une piece Bien ventil et a l cart des sources de chaleur telles que la lumi re directe du soleil et les radiateurs A P cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectriques Dans les r gions sujettes aux orages magn tiques nous vous recommandons de brancher votre syst amp me a un suppresseur de surtension et de d connecter les lignes de t l communication de votre modem pendant les orages Equip d une prise murale reli e la terre Equip d un espace suffisant pour acc der aux cordons d alimentation secteur car ils servent de disjoncteur principal d alimentation du produit Pratiques de manipulation de l quipement R duisez le risque de dommages personnels ou mat riels e Conformez vous aux exigences de m decine du travail et de s curit lorsque vous d placez et soulevez le mat riel Utilisez l assistance m canique ou toute autre assistance appropri e lorsque vous d placez et soulevez le mat riel Pour r duire le poids en vue de faciliter la manipulation retirez tout composant amovible 10
60. azar antes de extraerla del servidor Para evitar el riesgo de descargas el ctricas antes de abrir el servidor ap guelo desconecte el cable de alimentaci n los sistemas de telecomunicaciones las redes y los m dems conectados al mismo Advertencias sobre el cable de alimentaci n Precauci n Si no se ha proporcionado con el producto ning n cable de alimentaci n de CA adquiera alguno cuyo uso est aprobado en su pa s Para evitar descargas el ctricas o fuego revise los cables de alimentaci n que usar con el producto tal y como se describe a continuaci n No intente modificar ni utilizar los cables de alimentaci n de CA si no son exactamente del modelo especificado para ajustarse a las tomas de corriente conectadas a tierra Los cables de alimentaci n deben reunir los siguientes requisitos El cable de alimentaci n debe disponer de una capacidad nominal de corriente el ctrica mayor que la capacidad especificada en el producto El cable de alimentaci n debe disponer de una patilla o contacto de conexi n a tierra que sea apto para la toma de corriente Los cables de la fuente de alimentaci n son los dispositivos de desconexi n principales a la corriente alterna El enchufe o enchufes de z calo deben encontrarse cerca del equipo y el acceso a ellos debe poderse efectuar de forma inmediata con el fin de desconectarlos Intel Server Chassis SC5400 User s Guide 107 Los cables de la fuente de a
61. board over any surface Inte amp Server Chassis SC5400 User s Guide Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a jumper or you may bend or break the pins on the board Intel Server Chassis SC5400 User s Guide V vi Intel Server Chassis SC5400 User s Guide Preface About this Manual Thank you for purchasing and using the Intel Server Chassis SC5400 This manual is written for system technicians who are responsible for troubleshooting upgrading and repairing this server chassis This document provides a brief overview of the features of the chassis a list of accessories or other components you may need troubleshooting information and instructions on how to add and replace components on the Intel Server Chassis SC5400 For the latest version of this manual see http support intel com support motherboards server chassis SC5400 Ma
62. ca del modo de reposo o stand by NO DESCONECTA completamente la alimentaci n de CA del sistema ya que el modo de reposo de 5 V sigue activo mientras el sistema esta enchufado Para desconectar el sistema debe desenchufar el cable de alimentacion de CA de la toma de la pared Puede usar mas de un cable de alimentacion de CA con el sistema Asegurese de que todos los cables de alimentacion de CA estan desenchufados Asegurese de que los cables de alimentacion de CA est n desenchufado antes de abrir la carcasa agregar o extraer cualquier componente que no es de conexi n en funcionamiento Algunas fuentes de alimentacion de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje Para evitar riesgos de choques electricos use precauciones al trabajar con las fuentes de alimentacion que utilizan el polo neutral de fuselaje No intente modificar ni utilizar un cable de alimentaci n de CA si no es del tipo exacto requerido Se necesita un cable de CA para cada fuente de alimentaci n del sistema La fuente de alimentaci n de este producto no contiene piezas que puedan ser reparadas por el usuario No abra la fuente de alimentaci n Dentro de la fuente de alimentaci n puede haber niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n que va a reempl
63. chnical Product Specification If you just received this product and need to install it Intel Server Chassis SC5400 Quick Start User s Guide in the product box For virtual system tours and interactive repair information A link to the SMaRT Tool is available under Other Resources at the right side of the screen at http support intel com support motherboards server chassis SC5400 Accessories or other Intel server products Spares and Configuration Guide Hardware peripheral boards adapter cards and operating systems that have been tested with this product Tested Hardware Operating Systems List For software to manage your Intel server Intel System Management Software For diagnostics test software Diagnostics Intel Server Chassis SC5400 User s Guide Intel Server Chassis SC5400 User s Guide Contents Safety Information aa di iii Important Safety Instructions eu ae een iii Wichtige Sicherheitshinweise su iii Consignes de S CUrIR em nn iii Instrucciones de seguridad importantes iii l cago SES a a iv Preface m vii OE Manual TTE EIS T UE vii Manual Organization Wc vii Product Contents Order Options and Accessories pp viii Additional Information and Software nn ix Chapter 1 Server Chassis Features nee 1 Component Identification cia 6 Internal Componen
64. ctions see Removing and Installing the Front Bezel on page 18 9 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 10 Plug all peripheral devices and the AC power cable into the server 11 Power up the server 28 Intel Server Chassis SC5400 User s Guide Installing a DVD or CD ROM Drive 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 5 Remove an EMI shield slide assembly from the upper device bay by pressing the two slide assembly latches inward see letter A in the following figure Remove the slides from the EMI shield by pulling the slides away from the EMI shield to release them from the EMI shield see letter B AF000945 Figure 20 Removing EMI Shield Slide Assembly from Upper Device Bay 6 Attach slides to the DVD or CD ROM drive by pressing the slides firmly into the side dimples on the DVD or CD ROM drive AF000576 Figure 21 Attaching Slides to a DVD or CD ROM Drive Intel Server Chassis SC5400 User s Guide 29 10 11 12 Insert the drive slide assembly into the upper device bay until the slides lock int
65. damage system parts To install the covers Check first to make sure you have not left loose tools or parts inside the system Check that cables add in boards and other components are properly installed Attach the covers to the chassis according to the product instructions Laser Peripherals or Devices Caution To avoid risk of radiation exposure and or personal injury Do not open the enclosure of any laser peripheral or device Laser peripherals or devices have are not user serviceable Return to manufacturer for servicing 92 Intel Server Chassis SC5400 User s Guide Deutsch Sicherheitshinweise fur den Server Das vorliegende Dokument bezieht sich auf Intel Serverplatinen Intel Servergeh use Standfu und Rack sowie installierte Peripherieger te Es enth lt Warnungen und Vorsichtsma nahmen zur Vermeidung von Gefahren durch Verletzung Stromschlag Feuer und Besch digungen von Ger ten Lesen Sie diese Dokument daher sorgf ltig bevor Sie Ihr Intel Serverprodukt installieren oder warten Bei Widerspr chen zwischen den hier vorliegenden Angaben und den Informationen im Lieferumfang des Produkts oder auf der Website des betreffenden Produkts hat die Produktdokumentation Vorrang Die Integration und Wartung des Servers darf nur durch technisch qualifizierte Personen erfolgen Um die Einhaltung der vorhandenen Zulassungen und Genehmigungen f r das Produkt zu gew hrleisten sind die Richtlinien
66. deber desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentaci n INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interruptor encendido apagado 3 Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna 4 Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte posterior del sistema 5 Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una mu equera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s de completar las seis instrucciones de SEGURIDAD mencionadas ya puede extraer las tapas del sistema Para ello 1 Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema si se ha instalado uno 2 Extraiga y guarde todos los tornillos de las tapas Extraiga las tapas 124 Intel Server Chassis SC5400 User s Guide 2 Para obtener un enfriamiento y un flujo de aire adecuados reinstale siempre las tapas del chasis antes de poner en
67. e Processor and Memory Air Ducts on page 21 If desired install any PCI Add in boards For instructions see Installing PCI Add in Board s on page 47 Re install the front bezel assembly For instructions see Installing the Front Bezel Pedestal Only on page 19 Re install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Intel Server Chassis SC5400 User s Guide Connecting and Disconnecting Cables to or from Server Board Caution Use caution when routing cables to ensure that cables do not obstruct fan airflow 1 See your Intel Server Board User Guide or Quick Start User 5 Guide for cable connection locations If your server has a hot swap power supply secure the cables that route toward the server board to the chassis Connecting Cables to Server Board 1 If your server has a hot swap power supply connect the cables that route toward the server board to the chassis See your Intel Server Board User Guide or Quick Start User 5 Guide for cable connection locations Removing Cables from Server Board s 1 If your server has a hot swap power supply remove the cables that route toward the server board to the chassis See your Intel Server Board User Guide or Quick Start User 5 Guide for cable connection locations Intel Server Chassis SC5400 User
68. e reconnect power and data cables Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Intel Server Chassis SC5400 User s Guide Installing Fixed Hard Drive s 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 5 Push the blue plastic release mechanism upward to release the fixed drive cage see letter A in the following figure Pull the drive cage out about two inches see letter B so that it is partially exposed from the drive bay slot in the chassis Partially exposing the drive cage will make it easier to open the upper door of the drive cage Note As an alternative you may also fully remove the drive cage from its drive bay slot in the chassis Take care however to position the drive cage horizontally before opening the drive cage doors or the drive rails will spill out vv SP v fl pus lt a Popo Banoo
69. e extremely sensitive to ESD and always require careful handling After removing the board from its protective wrapper place it component side up on a grounded static free surface Do not slide the board over any surface When removing a full length add in card you must pull back on the latch on the plastic card guide at the front of the chassis to release the card from the card guide 1 2 3 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 Intel Server Chassis SC5400 User s Guide 47 5 Press in on the two plastic tabs see letter A in the following figure and remove the PCI add in card retainer Open the back panel PCI add in card retention device see letter B by pressing open from the inside of the chassis Remove the PCI slot shield see letter C if it has not already been removed by pushing the shield out from the inside of the chassis AF000954 Figure 50 Preparing Chassis for Addition of PCI Add in Board 6 Remove the PCI add in board from its protective wrapper Be careful not to touch the components or gold edge connectors Place the add in board on an anti static surface
70. e less than the wattage rating for your power supply Use the two worksheets in this section to calculate the total used by your configuration For current and voltage requirements of add in boards and peripherals see your vendor documents Worksheet Calculating DC Power Usage Table 9 Power Usage Worksheet Current maximum at voltage level Device 5 V Standby Baseboard Front Panel Board and Fans Processor s Memory 8 5 inch Diskette Drive CD ROM Drive Second 5 25 inch Device Third 5 25 inch Device 1st Hard Drive 2nd Hard Drive 3rd Hard Drive 4th Hard Drive 5th Hard Drive 6th Hard Drive Expansion Board 1 Expansion Board 2 Expansion Board 3 Expansion Board 4 Expansion Board 5 Expansion Board 6 Intel Remote Management Module Control Panel Total Current Intel Server Chassis SC5400 User s Guide 65 Worksheet Total Combined Power Used by the Server 3 From the previous worksheet enter the total current for each column 4 Multiply the voltage by the total current to get the total wattage for each voltage level Add the total wattage for each voltage level to arrive at the total combined power usage for the power subsystem Table 10 Power Usage Worksheet 2 Voltage level and total current Total Watts VX A W for each voltage level 3 3 V X ___A 5 V X ___A 12 V X ___A a
71. e to the drive carrier Remove the hard drive from the drive carrier AF000595 Figure 42 Removing Hard Drive from Drive Carrier 42 Intel Server Chassis SC5400 User s Guide 3 Ifnot replacing with another hard drive re install the plastic air baffle into the empty drive carrier Secure the plastic air baffle to the drive carrier using the four screws that were formerly attached to the hard drive Note Plastic air baffles are necessary in all empty drive carriers to ensure proper airflow within the chassis AF000950 Figure 43 Installing Plastic Air Baffle in Drive Carrier 4 With the black lever open insert the drive carrier into the drive cage Once inserted rotate the black lever upwards to latch the drive carrier into position AF000592 Figure 44 Inserting Drive Carrier into Hot Swap Cage Intel Server Chassis SC5400 User s Guide 43 Installing Hot Swap Drive s 1 Press in on the green latch see letter A in the following figure at the end of the drive carrier to disengage it from the hot swap drive cage 2 Pull out on the black lever see letter B to fully open the drive carrier When the lever reaches a fully opened position it will push the drive carrier out from the hot swap drive cage Slide the drive carrier out of the drive cage see letter C AF000589 Figure 45 Removing Drive Carrier from Hot Swap Cage 3 Remove the four screws tha
72. eable parts inside it servicing should be done by technically qualified personnel 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Remove the memory and processor air ducts For instructions see Removing the Processor and Memory Air Ducts on page 20 5 If present remove shipping screw securing hot swap power supply to chassis see letter A in the following figure Press on green latch see letter B while pulling on handle to remove power supply from chassis Repeat this step for the second hot swap power supply if one is installed AF000956 Figure 58 Removing Hot Swap Power Supply from Chassis 6 Disconnect all internal power cables from chassis components and server board 54 Intel Server Chassis SC5400 User s Guide 7 Remove screw see letter A in the following figure securing center divider to the a Ly power supply cage Push center divider straight back see letter B to release tabs and sideways see letter C Remove center divider from power supply cage see letter D from chassis slots Then while holding the right edge of the center divider at a downward angle disengage tabs from chassis wall by pushing center divider up 7 IN AS
73. en Batterietyp ersetzt werden Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend 120 Intel Server Chassis SC5400 User s Guide Das System wurde f r den Betrieb in einer normalen B roumgebung entwickelt Der Standort sollte sauber und staubfrei sein Hausstaub ausgenommen gut gel ftet und keinen Heizquellen ausgesetzt sein einschlie lich direkter Sonneneinstrahlung keinen Ersch tterungen ausgesetzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem Uberspannungsschutzgerat verbunden sein w hrend eines elektrischen Sturms sollte keine Verbindung der Telekommunikationsleitungen mit dem Modem bestehen mit einer geerdeten Wechselstromsteckdose ausger stet sein ber ausreichend Platz verf gen um Zugang zu den Netzkabeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird Intel Server Chassis SC5400 User s Guide 121 Francais Le bloc d alimentation de ce produit ne contient aucune piece pouvant tre r par e par l utilisateur Ce produit peut contenir plus d un bloc d alimentation Veuillez contacter un technicien qualifi en cas de probleme Ne pas essayer d utiliser ni modifier le cable d alimentation CA fourni s il ne correspond pas exactement au type requis Le nombre de cables d alimentatio
74. entative This is an FCC Class A device Integration of it into a Class B system does not result in a Class B device Product Safety Compliance This server chassis product when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial telecommunications NEBS residential alarm systems test equipment etc other than an ITE application may require further evaluation Intel Server Chassis SC5400 User s Guide 71 Product Regulatory Compliance References The following table references Server Chassis Compliance and markings that may appear on the product Markings below are typical markings however may vary or be different based on how certification is obtained Note Certifications Emissions requirements are to Class A Table 11 Product Regulatory Compliance Markings Compliance Regional Description Compliance Reference Compliance Reference Marking Example Australia New Zealand AS NZS 3548 Emissions v N232 Argentina IRAM Certification Safety G Belarus Belarus None Required Certification Canada USA CSA
75. er ou d endommager la pile d une quelconque fa on Refroidissement et ventilation Attention Routez les c bles avec pr caution comme indiqu pour minimiser les blocages de circulation d air et les problemes de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le syst me en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me sans les panneaux peut endommager les composants syst me Pour installer les panneaux V rifiez tout d abord que vous n avez pas oubli d outils ou de composants d tach s l int rieur du syst me V rifiez que les c bles les cartes d extension et les autres composants sont correctement install s Fixez les panneaux au ch ssis en suivant les instructions du produit Intel Server Chassis SC5400 User s Guide 103 Peripheriques laser Attention Pour viter tout risque d exposition aux rayonnements et ou de dommage personnel N ouvrez pas l enceinte d un p riph rique laser Les p riph riques laser ne sont pas r parables par l utilisateur Retournez les au fabricant en cas de probl me 104 Intel Server Chassis SC5400 User s Guide Espanol Informacion de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel las carcasas de servidor de Intel montaje en bastidor y en pedestal y los dispositivos perif ricos Para reducir el riesgo de da os corporales descarga
76. es applicables aux appareils num riques de Classe A prescrites dans la norme sur le mat riel brouilleur Apparelis Num riques NMB 003 dictee par le Ministre Canadian des Communications English translation of the notice above This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Directive 89 336 EEC The product has been marked with the CE Mark to illustrate its compliance VCCI Japan CORB REST ERRE TANA VCCI DEM KRIST SAAMMEWRE CT CORBERERA CERT S CU HERBERITIEREHET OGGE IEEE AEE RT BKSERENDTIEMBNET English translation of the preceding notice This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI from Information Technology Equipment If this is used near a radio or television receiver in a domestic environment it may cause radio interference Install and use the equipment according to the instruction manual BSMI en E ER
77. f necessary 6 Remove the PCI add in card retainer Press in on the two plastic tabs see letter A in the following figure to release the PCI add in card retainer from the chassis Intel Server Chassis SC5400 User s Guide 45 46 Open the back panel PCI add in card retention device see letter B by pressing open from the inside of the chassis AS Pd AF000600 Figure 49 Preparing Chassis for Removal of PCI Add in Board Intel Server Chassis SC5400 User s Guide 7 10 11 12 Firmly grab the PCI add in board by its top edge or outer corners and remove from the expansion slot on the server board Place the removed PCI add in board in an anti static protective wrapper Close the back panel PCI add in card retention device Remove additional PCI add in boards as necessary When done reinstall the PCI add in card retainer and close the PCI add in card retention device s Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Installing PCI Add in Board s Caution You may want to install an operating system before installing any add in boards Do not overload the server board by installing add in boards that draw excessive current Add in boards can b
78. ffnen oder sonstwie zu besch digen K hlung und Luftstrom Vorsicht Verlegen Sie Kabel sorgf ltig entsprechend der Anleitung um St rungen des Luftstroms und K hlungsprobleme zu vermeiden Zur Gew hrleistung des ordnungsgem en K hlungs und Luftstromverhaltens darf das System nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an e Vergewissern Sie sich zun chst da Sie keine Werkzeuge oder Teile im Geh use vergessen haben Pr fen Sie ob Kabel Erweiterungskarten sowie weitere Komponenten ordnungsgem angebracht sind Befestigen Sie die Abdeckungen am Geh use des Produkts wie in dessen Anleitung beschrieben Laser Peripherieger te oder Komponenten Vorsicht Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise ffnen Sie keinesfalls das Geh use von Laser Peripherieger ten oder Laser Komponenten Laser Peripheriegerdte oder Komponenten besitzen keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck 98 Intel Server Chassis SC5400 User s Guide Francais Consignes de s curit sur le serveur Ce document s applique aux cartes serveur Intel au chassis de serveur Intel sur pieds et sur rack et aux p riph riques install s Pour r duire les
79. g a Slimline USB Floppy CD DVD Slimline Kit i 26 Removing a Slimline USB Floppy CD DVD Combo ee 26 Removing and Installing a DVD or CD ROM Drive ppp 27 Removing a DVD or CD ROM Drive iris 27 Installing a DVD or CD ROM Drive u 29 Removing and Installing Fixed Hard Drive S pp 30 Removing Fixed Hard Drive S 444444444400nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn 30 Installing Fixed Hard Drive S zus vated genio eae 35 Routing Power Cables to Fixed Drives pp 40 Routing Data Cables to Fixed Drives ss 41 Removing and Installing Hot Swap Drive S ii 42 Removing Hot Swap Drive S ae a 42 Installing Hot Swap DNS essen eae ees 44 Removing and Installing PCI Add in Board s pp 45 Removing PCI Add in Boardis cri ia Maddie 45 Installing PCI Add in Board S oococconncccccnnncccccnonanaccnonanancnnn nan ncnnnnnnnnnnnnnn cnn nnnnnnncnnnns 47 Installing Additional Hot Swap Power Supply Module pp 51 Replacing a Hot Swap Power Supply iii 52 Replacing a Fixed Power Supply pp 53 Replacing the Power Distribution Board nen nnnnnnnnnnnnnnnnnn naar 54 Replacing the Control Panel nen 59 Installing and or Removing a Server Board pp 60 Connecting and Disconnecting Cables to or from Server Board 61 Connecting Cables to Server Board rnnnrrnrrnnnnvnnrrnnnnnnnnvnnnrnnnnnnnnrrrrnnnnnnnnvennnnnnnnnne 61 Removing Cables from Server Board s pp 61 Chapter 3 Technical Reference nee 63
80. gati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3 Togliere tutte le spine dei cavi del sistema dalle prese elettriche 4 Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sistema qualsiasi superficie non dipinta 6 Non far operare il sistema quando il telaio senza le coperture Dopo aver seguito i sei passi di SICUREZZA sopracitati togliere le coperture del telaio del sistema come seque 1 Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture 126 Intel Server Chassis SC5400 User s Guide Per il giusto flusso dell aria e raffreddamento del sistema rimettere sempre le coperture del telaio prima di riaccendere il sistema Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema Per rimettere le coperture del telaio 1 Controllare prima che non si siano lasciati degli attrezzi o dei componenti dentro il sistema 2 Controllare che i cavi dei supporti aggiuntivi ed altri componenti siano stati installati appropria
81. holding in the blue button at the top of the chassis see letter B slide the top cover back until it stops Lift the cover outward to remove it AF000555 Figure 7 Removing the Chassis Cover 16 Intel Server Chassis SC5400 User s Guide Installing the Chassis Cover 1 Slide the chassis cover on the chassis 2 Latch the cover securely to the chassis 3 Ifthe chassis will be re shipped secure the chassis cover to the chassis with the access cover screw see letter A in the following figure AF000572 Figure 8 Installing the Chassis Cover Intel Server Chassis SC5400 User s Guide 17 Removing and Installing the Front Bezel Removing the Bezel Assembly Pedestal Only Caution Do not rotate the bezel assembly more than 40 degrees or you will damage the bezel assembly Note The bezel assembly consists of two components a front door and a sub bezel 1 2 3 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Release the two plastic tabs see letter A in the following figure on the left side of the bezel assembly to disengage the tabs Rotate the bezel assembly see letter B no more than 40 degrees outward At a 40 degree angle push the bezel assembly away from the chassis
82. icaciones que lo identifiquen como el control de alimentaci n el ctrica de toda la unidad no s lo de los servidores Para evitar el riesgo de descargas el ctricas deber instalar una conexi n a tierra apropiada para el bastidor y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de disco las tarjetas y otros componentes Recomendamos que realice todos los procedimientos en una estaci n de trabajo protegida contra descargas electrost ticas En caso de que no haya una disponible prot jase de alguna forma contras las descargas llevando un brazalete antiest tico conectado a la toma de tierra de la carcasa cualquier superficie de metal que no est pintada del servidor cuando manipule las piezas Manipule siempre las tarjetas con el m ximo cuidado Pueden ser sumamente sensibles a las descargas electrost ticas Suj telas s lo por los bordes Una vez extra da la tarjeta de su envoltorio de protecci n o del servidor col quela con el lado de los componentes hacia arriba sobre una superficie con toma de tiearra y sin carga est tica Utilice una almohadilla de espuma conductora si dispone de ella pero nunca el envoltorio de la tarjeta No deslice la tarjeta sobre ninguna superficie Sustituci n de la bater a Precauci n Existe el peligro de explosi n si la bater a no se reemplaza correctamente Al reemplazar la bater a ut
83. ilice s lo la bater a recomendada por el fabricante del equipo Deseche las bater as respetando la normativa local No intente recargar la bater a No intente desmontar pinchar o causar cualquier otro desperfecto a una bater a Enfriamiento y circulaci n de aire Precauci n El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para reducir al m nimo los problemas de obstrucci n de la ventilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistema sin las cubiertas podr a da ar sus componentes Para instalar las cubiertas Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema e Compruebe que los cables tarjetas adicionales y otros componentes est n instalados correctamente Intel Server Chassis SC5400 User s Guide 109 Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto Perifericos o dispositivos laser Precauci n Para evitar el riesgo de la exposici n a radiaciones o de da os personales No abra la caja de ningun perif rico o dispositivo l ser Los perif ricos o dispositivos l ser no pueden ser reparados por el usuario Haga que el fabricante los repare 110 Intel Server Chassis SC5400 User s Guide
84. in Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Daher sollten Sie alle Arbeiten an einer ESD Workstation ausf hren Steht ein solcher Arbeitsplatz nicht zur Verf gung erzielen Sie einen gewissen Schutz vor elektrostatischen Entladungen durch Tragen einer Antistatik Manschette die Sie w hrend der Arbeit zur Erdung an einem beliebigen unlackierten Metallteil des Computergeh uses befestigen Gehen Sei bei der Handhabung von Platinen immer mit gr ter Vorsicht vor Sie k nnen u erst empfindlich gegen ber elektrostatischer Entladung sein Halten Sie Platinen nur an den Kanten fest Legen Sie die Platinen nach dem Auspacken aus der Schutzh lle oder nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete statisch entladene Unterlage Verwenden Sie dazu sofern verf gbar eine leitfahige Schaumstoffunterlage aber niche die Schutzh lle der Platine Ziehen Sie die Platine nicht ber eine Fl che Intel Server Chassis SC5400 User s Guide 97 Andere Gefahren Batterieaustausch Vorsicht Wird die Batterie unsachgem ausgetauscht besteht Explosionsgefahr Verwenden Sie als Ersatz nur die vom Ger tehersteller empfohlene Batterie Beachten Sie bei der Entsorgung von Batterien die g ltigen Bestimmungen Versuchen Sie nicht eine Batterie aufzuladen Versuchen Sie nicht eine Batterie zu
85. into the drive cage 12 Close the lower door of drive cage AF000584 Figure 36 Closing Lower Door of Fixed Drive Cage 38 Intel Server Chassis SC5400 User s Guide 13 Close the upper door of drive cage AF000585 Figure 37 Closing Upper Door of Fixed Drive Cage 14 Tighten the captive screw AF000586 Figure 38 Tightening Captive Screw 15 Re install fixed drive cage into chassis 16 Connect power and data cables to connectors on hard drive s 17 Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 18 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 19 Plug all peripheral devices and the AC power cable into the server 20 Power up the server Intel Server Chassis SC5400 User s Guide 39 Routing Power Cables to Fixed Drives Power Cable Routing Chassis Primary Side View r To Upper Device Bay To 4 Drive Cage I DU T To 6 Drive Cage DITTIK C PCI Add in card retainer detail AF000510 Figure 39 Routing Power Cables to Fixed Drives Route longest power cables to the 6 drive bay and shorter cables to the 4 drive bay and upper device bay Power Cable Routing Guidelines P3 PA and P5 power cables route to removable drives P
86. ipment installed in it Intel Server Chassis SC5400 User s Guide Electrostatic Discharge ESD Caution ESD can damage disk drives boards and other parts We recommend that you perform all procedures at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Other Hazards Battery Replacement Caution There is the danger of explosion if the battery is incorrectly replaced When replacing the battery use only the battery recommended by the equipment manufacturer Dispose of batteries according to local ordinances and regulations Do not attempt to recharge a battery Do not attempt to disassemble puncture or otherwise damage a battery Intel Server Chassis SC5400 User s Guide 91 Cooling and Airflow Caution Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the system without the covers in place can
87. is with the processor and memory air ducts in place The air ducts are required for proper airflow within the chassis For instructions on adding or replacing a processor first remove the processor and memory air ducts and then see your server board user guide for instructions on processor installations and removals Return to these instructions to reinstall the processor and memory air ducts after installing your processor and heat sink Removing the Processor and Memory Air Ducts 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Press the latch on the memory air duct to disengage it from the server board see letter A in the following figure 5 Detach the memory air duct from the processor air duct see letter B 6 Remove the processor air duct see letter C AF000321 Figure 11 Removing the Processor and Memory Air Ducts 20 Inte amp Server Chassis SC5400 User s Guide Installing the Processor and Memory Air Ducts 1 If your system has two processors remove the inner plastic air baffle from the inside of the processor air duct see letter A in the following figure Caution This step only applies to systems with two processors If
88. l office environment Choose a site that is Clean dry and free of airborne particles other than normal room dust Well ventilated and away from sources of heat including direct sunlight and radiators Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect Equipment Handling Practices 88 Reduce the risk of personal injury or equipment damage Conform to local occupational health and safety requirements when moving and lifting equipment Use mechanical assistance or other suitable assistance when moving and lifting equipment Intel Server Chassis SC5400 User s Guide e To reduce the weight for easier handling remove any easily detachable components Power and Electrical Warnings Caution The power button indicated by the stand by power marking DOES NOT completely turn off the system AC power 5V standby power is active whenever the system is plugged in To remove power from system you must unplug the AC power cord from the wall outlet Your system may use more than one AC power cord
89. limentacion deben estar conectados a los enchufes con una toma de tierra adecuada Advertencias el acceso al sistema Precauci n Para evitar lesiones personales o da os en la propiedad se aplican las siguientes instrucciones de seguridad siempre que se acceda al interior del producto Apague todos los dispositivos perif ricos conectados a este producto Pulse el bot n de alimentaci n para apagar el sistema Desconecte la alimentaci n de CA desenchufando los cables de alimentaci n de CA del sistema o de la toma de corriente alterna Desconecte todos los cables y l neas de telecomunicaci n que est n conectados al sistema Guarde todos los tornillos o elementos de fijaci n cuando retire las cubiertas de acceso Cuando termine de operar en el interior del producto vuelva a colocar los tornillos o los elementos de fijaci n originales de la cubierta de acceso No acceda al interior de la fuente de alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor y desconecte todos los cables de alimentaci n antes de agregar o reemplazar cualquier componente que no es de conexi n en funcionamiento Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n que va a reemplazar antes de extraerla del servidor Precauci n Si el servidor se ha estado
90. m Umgang mit Netzteilen welche Nullleitersicherungen verwenden um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enth lt keine Teile die vom Benutzer gewartet werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen Zur Vermeidung von Stromschl gen schalten Sie den Server aus und trennen Sie vor dem ffnen des Ger ts das Netzkabel sowie alle an den Server angeschlossene Telekommunikationssysteme Netzwerke und Modems Intel Server Chassis SC5400 User s Guide 95 Hinweis fur Netzkabel Wenn kein Netzkabel mit dem Produkt geliefert wurde kaufen Sie ein Kabel das f r die Vorsicht Priifen Sie zur Vermeidung von Stromschlag oder Feuergefahr die mit dem Produkt zu verwendenden Netzkabel wie folgt Nehmen Sie keine Anderungen an einem Netzkabel vor und benutzen sie es nicht wenn es nicht genau in die geerdeten Netzsteckdosen pa t Netzkabel m ssen die folgenden Anforderungen erf llen Die Nennbelastbarkeit des Netzkabels mu mindestens so hoch sein wie die am Produkt angegebenen Nennstromaufnahme Das Netzkabel mu einen zur Netzsteckdose passenden Schutzkontakt besitzen Die Netzkabel sind die Hauptvorrichtung zum Trennen des
91. ment provides instructions for adding and replacing chassis components For instructions on replacing components on the server board such as the processor and memory DIMMs see the instructions provided with the server board Tools and Supplies Needed Phillips cross head screwdriver 1 bit and 2 bit Needle nosed pliers Anti static wrist strap and conductive foam pad recommended System References All references to left right front top and bottom assume the reader is facing the front of the chassis as it would be positioned for normal operation Intel Server Chassis SC5400 User s Guide 15 Removing and Installing the Chassis Cover Removing the Chassis Cover The Intel Server Chassis SC5400 must be operated with the top cover in place to ensure proper cooling You will need to remove the top cover to add or replace components inside of the platform Before removing the top cover power down the server and unplug all peripheral devices and the AC power cable Note A non skid surface or a stop behind the chassis may be needed to prevent the chassis from sliding on your work surface 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Turn off all peripheral devices connected to the server Turn off the server 3 Disconnect the AC power cord 4 Remove the access cover screw if it is installed see letter A in the following figure While
92. mline USB Floppy CD DVD Slimline Kit Refer to the Slimline USB Floppy CD ROM DVD ROM Drive Kit Install Guide that shipped with your slimline combo kit for installation instructions Removing a Slimline USB Floppy CD DVD Combo 1 2 3 26 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 Disconnect the power and data cables to the slimline combo drive assembly Remove the combo drive slide assembly from the chassis by pressing in on the slide release latches see letter A in the following figure Remove the slides from the slimline combo drive tray by pulling the slides away from the tray see letter B A gentle pull should release the slide from the side dimple on the drive tray AF000575 Figure 17 Removing Slide Drive Assembly from Upper Device Bay Intel Server Chassis SC5400 User s Guide 7 Ifnot replacing with another drive re attach pair of slides to an EMI shield and re insert EMI shield slide assembly into chassis for proper airflow AF000605 Figure 18 Re inserting Empty EMI Shield Slide Assembly into Chassis 8 Install the front bezel For instructions see Removing a
93. mmarizes the features of the LX SKU Table 3 Server Chassis Features LX SKU Feature Description Dimensions 16 6 inches high Pedestal 17 inches 8 6 inches wide 27 4 inches deep Pedestal 28 4 inches 36 2 kilograms Hard Drives One fixed drive bay for up to six fixed SAS or SATA drives Optional hot swap drive bays Six drive SAS SATA Four drive SAS SATA An optional four drive fixed drive bay is also available Supports up to ten drives Peripherals Three multi mount 5 25 inch peripheral bays Control Panel dependent on option selected Front Control Panel Intel Local Control Panel optional LEDs and displays dependent on option selected With Front Control Panel NIC1 Activity NIC2 Activity Power Sleep System Status System Identification Hard Drive Activity Power Supply One redundant capable 830 W power supply module with an integrated cooling fan Optional second redundant power supply module is available Fans Four hot swap redundant chassis fans Two 120 mm fans Two 92 mm fans USB 2 0 Two front panel USB ports with Front Control Panel Four back panel USB ports Video One front panel video port available only with Standard Control Panel One rear panel video port Intel Server Chassis SC5400 User s Guide Table 3 summarizes the features of the SC5400LXi SKU Table 4 Server Chassis Features L
94. mpliance Reference Marking Example California California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials Special handling may apply See www dtsc ca gov hazardouswaste perchlorate This notice is required by California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlorate Materials This product part includes a battery which contains Perchlorate material China China RoHS Administrative Measures on the Control of Pollution Caused by Electronic Information Products EIP 39 Referred to as China RoHS Mark requires to be applied to retail products only Mark used is the Environmental Friendly Use Period EFUP Number represents years G China Recycling GB18455 2001 Mark requires to be applied to be retail product only Marking applied to bulk packaging and single packages Not applied to internal packaging such as plastics foams etc E Intel Internal Specification All materials parts and subassemblies must not contain restricted materials as defined in Intel s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers http supplier intel com ehs environmental htm None Required Europe 78 Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC Mark applied to system level products only Intel Server Chas
95. n CA fournis correspond au nombre de blocs d alimentation du produit Notez que le commutateur CC de mise sous tension hors tension du panneau avant n teint pas l alimentation CA du systeme Pour mettre le systeme hors tension vous devez d brancher chaque cable d alimentation de sa prise CONSIGNES DE SECURITE Lorsque vous ouvrez le boitier pour acc der a l int rieur du systeme suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au systeme 2 Mettez le systeme hors tension en mettant l interrupteur g n ral en position OFF bouton poussoir 3 D branchez tous les cordons d alimentation c a du systeme et des prises murales 4 Identifiez et d branchez tous les cables reli s aux connecteurs d E S ou aux acc s derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la a la masse du systeme toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vous pouvez retirer les panneaux du syst me Proc dez comme suit 1 Si un cadenas a t install sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 8 Retirez les panneaux 122 Intel
96. nd Installing the Front Bezel on page 18 9 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 10 Plug all peripheral devices and the AC power cable into the server 11 Power up the server Removing and Installing a DVD or CD ROM Drive Removing a DVD or CD ROM Drive 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 5 Disconnect the power and data cables to the DVD CD ROM drive Intel Server Chassis SC5400 User s Guide 27 6 Remove the DVD CD ROM drive slide assembly from the chassis by pressing in on the slide release latches see letter A in the following figure Remove the slides from the DVD or CD ROM drive by pulling the slides away from the drive see letter B A gentle pull should release the slide from the side dimple on the drive AF000575 7 If not replacing with another drive re attach pair of slides to an EMI shield and re insert EMI shield slide assembly into chassis for proper airflow AF000605 Figure 19 Re inserting Empty EMI Shield Slide Assembly into Chassis 8 Install the front bezel For instru
97. nstall dans le rack doivent tre correctement reli s a la terre Decharges lectrostatiques ESD Attention Les d charges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pieces Il est fortement conseille d effectuer l ensemble des proc dures decrites a un poste de travail protege contre les ESD Au cas ou aucun poste de ce type ne serait disponible protegez vous contre les ESD en portant un bracelet antistatique relie a la masse du chassis n importe quelle surface m tallique non peinte de votre serveur lorsque que vous manipulez les pieces Manipulez toujours les cartes avec pr caution Elles peuvent tre extr mement sensibles aux ESD Ne tenez les cartes que par leurs bords Apres avoir retir une carte de son emballage de protection ou du serveur placez la sur une surface reli e a la terre exempte de charge statique composants orient s vers le haut Utilisez si possible un tapi de mousse conducteru mais pas l emballage de la carte Veillez a ce que la carte ne glisse sur aucune surface Autres risques Remplacement de la pile Attention Il existe un risque d explosion si la pile n est pas correctement remplac e Lors du remplacement de la pile utilisez uniquement celle recommandee par le fabricant du mat riel Mettez la pile au rebut en vous conformant aux r glementations locales N essayez pas de recharger une pile N essayez pas de d monter de perc
98. nual Organization vii Chapter 1 provides a brief overview of the Intel Server Chassis SC5400 In this chapter you will find a list of the server chassis features photos of the product and product diagrams to help you identify components and their locations Chapter 2 provides instructions on adding and replacing components Use this chapter for step by step instructions and diagrams for installing or replacing components such as the fans power supply drives and other components Chapter 3 provides technical reference information on cable routing power supply specifications and system environment requirements At the back of this document you will find appendices on safety regulatory getting help and warranty information Product Contents Order Options and Accessories This server chassis is compatible with the following Intel Server Boards Intel Server Board S5000PSL Intel Server Board S5000XVN Your Intel Server Chassis SC5400 ships with the following items 670W or 830W power supply installed in the chassis A box of hardware components referred to below as the chassis hardware box Fan cables installed in the Intel Server Chassis SC5400 with product code SC5400LX or SC5400LXi Chassis intrusion switch installed in the chassis Attention document in the chassis product box Intel Server Chassis SC5400 Quick Start User s Guide in the chassis hardware box Six 32 6mm flat screws for installing d
99. o place Connect power and data cables Install the front bezel For instructions see Removing and Installing the Front Bezel on page 18 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Removing and Installing Fixed Hard Drive s Removing Fixed Hard Drive s 1 2 3 Observe the safety and ESD precautions at the beginning of this book Power down the server and unplug all peripheral devices and the AC power cable Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 Push the blue plastic release mechanism upward to release the fixed drive cage see letter A in the following figure Remove power and data cables from the hard drive connectors Pull the drive cage out about two inches see letter B so that it is partially exposed from the drive bay slot in the chassis Partially exposing the drive cage will make it easier to open the upper door of the drive cage Note As an alternative you may also fully remove the drive cage from its drive bay 30 slot in the chassis Take care however to position the drive cage horizontally before opening the drive cage doors or the drive rails will spill out
100. on locations 11 Reconnect power cables to other chassis components as appropriate Intel Server Chassis SC5400 User s Guide 57 12 Reinstall center divider see letter A in the following figure and secure to chassis with one screw see letter B TP00843 Figure 62 Re installing Center Divider in the following figure if shipping chassis to another location SAR 13 Insert hot swap power supply ies into chassis Replace shipping screw s see letter AF000603 ing Hot Swap Power Supply into Chassis Figure 63 Install Intel Server Chassis SC5400 User s Guide 58 14 15 16 17 Re install the memory and processor air ducts For instructions see Installing the Processor and Memory Air Ducts on page 21 Re install the chassis cover For instructions see Installing the Chassis Cover on page 17 Plug all peripheral devices and the AC power cable into the server Power up the server Replacing the Control Panel The steps for replacing the front control panel and the Intel Local Control Panel are nearly identical Use the following steps for both varieties of the control panel Where necessary differences between the two control panels are noted Your server must be operated with a control panel installed Caution The control panel is NOT hot swappable Before removing or replacing the control panel you must first take the server out of service turn off
101. onnected dial 800 843 4481 Intel Server Chassis SC5400 User s Guide 69 70 Intel Server Chassis SC5400 User s Guide
102. ory Air DUCTS i 22 Figure 14 Removing Fixed Fan een 23 Figure 15 Removing Hot Swap Fall 24 Figure 16 Installing Hot Swap Fan ii 25 Figure 17 Removing Slide Drive Assembly from Upper Device Bay 26 Figure 18 Re inserting Empty EMI Shield Slide Assembly into Chassis 27 Figure 19 Re inserting Empty EMI Shield Slide Assembly into Chassis 28 Figure 20 Removing EMI Shield Slide Assembly from Upper Device Bay 29 Figure 21 Attaching Slides to a DVD or CD ROM Drive pp 29 Figure 22 Removing Six drive Fixed Drive Cage from Chassis pp 31 Figure 23 Unlocking and Opening Upper Door of Fixed Drive Cage ee 31 Figure 24 Opening Lower Door of Fixed Drive Cage ppp 32 Figure 25 Removing Drive Slide Assembly from Drive Cage 32 Figure 26 Inserting Empty Device Slides into Drive Cage 33 Figure 27 Closing Lower Door of Fixed Drive Cage net 33 Figure 28 Closing Upper Door of Fixed Drive Cage 34 Figure 29 Tightening Thumb Screw pp 34 Figure 30 Removing Six drive Fixed Drive Cage from Chassis iii 35 Figure 31 Unlocking and Opening Upper Door of Fixed Drive Cage ee 36 Figure 32 Opening Lower Door of Fixed Drive Cage pp 36 Figure 33 Removing Slides from Drive Cage 37 Figure 34 Attaching Device Slides to Hard Drive pp 37 Figure 35 Inserting Drive Slide Assembly into Drive Cage 38 Figure 36 Cl
103. ory approvals of the product and will most likely result in non compliance with product regulations in the region s in which the product is sold System power on off The power button DOES NOT turn off the system AC power To remove power from system you must unplug the AC power cord from the wall outlet Make sure the AC power cord is unplugged before you open the chassis add or remove any components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an anti static wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts ESD and handling boards Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide
104. osing Lower Door of Fixed Drive Cage 38 Figure 37 Closing Upper Door of Fixed Drive Cage 39 Figure 38 Tightening Captive Screw sise 39 Figure 39 Routing Power Cables to Fixed Drives pp 40 Figure 40 Routing SAS SATA Data Cables pp 41 Figure 41 Releasing Drive Carrier from Hot Swap Cage nn 42 Figure 42 Removing Hard Drive from Drive Carrier 42 Intel amp Server Chassis SC5400 User s Guide XV Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 xvi Installing Plastic Air Baffle in Drive Carrier 43 Inserting Drive Carrier into Hot Swap Cage 43 Removing Drive Carrier from Hot Swap Cage 44 Removing Plastic Air Baffle sincera 44 Securing Hard Drive to Drive Carrier ss 45 Inserting Drive Carrier into Hot Swap Cage 45 Preparing Chassis for Removal of PCI Add in Board 46 Preparing Chassis for Addition of PCI Add in Board ppp 48 Installing Add in Boargd srl 49 Reinstalling PCI Add in Card Retainer pp 50 Removing Power Supply Filler Panel pp 51 Installing Additional Hot Swap Power Supply Module en 51 Removing Hot Swap Power Supply from Chassis 52 Installing Hot Swap Power Supply into Chassis pp 52 Removing Fixed Power Supply 53 Removing Hot Swap Power Supply from ChassiSs 54 REMOVING Center Divider se
105. pplicable law shall be that of Singapore for Europe and the rest of the world the forum shall be London and the applicable law shall be that of the United Kingdom Intel Server Chassis SC5400 User s Guide In the event of any conflict between the English language version and any other translated version s of this Limited Warranty the English language version shall control How to Obtain Warranty Service To obtain warranty service for this Product you may contact Intel or your authorized distributor North America and Latin America To obtain warranty repair for the product please go to the following Web site to obtain instructions http support intel com support motherboards draform htm In Europe and in Asia Contact your original authorized distributor for warranty service Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period Telephone Support If you cannot find the information you need on Intel s World Wide Web site http www intel com call your local distributor or an Intel Customer Support representative See Getting Help for telephone numbers Returning a Defective Product Before returning any product call your authorized dealer distribution authority Intel Server Chassis SC5400 User s Guide 85 86 Intel Server Chassis SC5400 User s Guide Appendix A Getting Help World
106. rd This Limited Warranty and any implied warranties that may exist under state law apply only to the original purchaser of the Product Intel Server Chassis SC5400 User s Guide 83 Extent of Limited Warranty Intel does not warrant that Products to be delivered hereunder whether delivered stand alone or integrated with other Products including without limitation semiconductor components will be free from design defects or errors known as errata Current characterized errata are available upon request This Limited Warranty does not cover damages due to external causes including accident problems with electrical power usage not in accordance with product instructions misuse neglect alteration repair improper installation or improper testing Warranty Limitations and Exclusions These warranties replace all other warranties expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Intel makes no expressed warranties beyond those stated here Intel disclaims all other warranties expressed or implied including without limitation implied warranties of merchantability and fitness for a particular purpose Some jurisdictions do not allow the exclusion of implied warranties so this limitation may not apply All expressed and implied warranties are limited in duration to the limited warranty period No warranties apply after that period Some jurisdiction
107. rive component in the chassis hardware box Seven screws for mounting the server board into the chassis in the chassis hardware box USB cable in the chassis hardware box COM2 cable in the hardware box In addition you may need or want to purchase one or more of the following accessory items for your server Processor memory DIMMs hard drive floppy drive CD ROM or DVD ROM drive RAID controller operating system For information about which accessories memory processors and third party hardware have been tested and can be used with your board and for ordering information for Intel products see http support intel com support motherboards server chassis SC5400 compat htm viii Intel Server Chassis SC5400 User s Guide Additional Information and Software If you need more information about this product or information about the accessories that can be used with this server chassis use the following resources These files are available at http support intel com support motherboards server chassis SC5400 Unless otherwise indicated in the table below once on this Web page type the document or software name in the search field at the left side of the screen and select the option to search This Product For this information or software Use this Document or Software For in depth technical information about this product including BIOS settings and chipset information IIntef Server Chassis SC5400 Te
108. rking Example Stand by Stand by Power Warnings Power Applied to product if stand by power switch is used O Multiple Power Cords Multiple Power Cords Warnings Applied to product if more than one power cord is used English This unit has more than one power supply cord To reduce the risk of electrical shock disconnect 2 two power supply cords before servicing Simplified Chinese ER C2 Traditional Chinese 2 German Dieses Gerate hat mehr als ein Stromkabel Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide 2 Stromkabeln bevor Instandhaltung 80 Intel Server Chassis SC5400 User s Guide Compliance Description Compliance Reference Compliance Reference Marking Example Ground Ground Connection Warnings Linet Connection WARNING Swedish on line2 Apparaten skall anslutas till jordat uttag n r den ansluts till ett n tverk Finnish on line 3 Laite on liitettava suojamaadoituskoskettimilla varustettuun pistorasiaan English on line 4 Connect only to a properly earth grounded outlet Regulated Specified Component
109. rve the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Disconnect the appropriate fan power cable from the server board Remove the 92 mm see letter A in the following figure or 120 mm see letter B fixed fan from its snap in bracket 120 mm Fixed Fan UT A UN E 9 TP00991 Figure 14 Removing a Fixed Fan 6 Install new 92 mm or 120 mm fixed fan Connect fan power cable to the server board See the Intel server board Quick Start User s Guide or User Guide for appropriate connection location 8 Re install the chassis cover For instructions see Installing the Chassis Cover on page 17 9 Plug all peripheral devices and the AC power cable into the server and then power up the server Intel Server Chassis SC5400 User s Guide 23 Removing and Installing Hot Swap Fans Intel Server Chassis SC5400LX or SC5400LXi Only Removing Hot Swap Fans Note This procedure applies only to the Intel Server Chassis SC5400LX and SC5400LXi configurations The Intel Server Chassis SC5400 BASE and Intel Server Chassis SC5400BRP configurations ship with fixed fans The hot swap fans from the Intel Server Chassis SC5300LX cannot be used in the Intel Server Chassis SC5400LX or SC5400LXi 1
110. s To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated components must be used and conditions adhered to Interchanging or use of other components will void the UL listing and other product certifications and approvals Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL http channel intel com go serverbuilder If you do not have access to Intel s Web address please contact your local Intel representative Server Chassis base chassis is provided with power supply and fans UL listed Server board you must use an Intel server board UL recognized Add in boards must have a printed wiring board flammability rating of minimum UL94V 1 Add in boards containing external power connectors and or lithium batteries must be UL recognized or UL listed Any add in board containing modem telecommunication circuitry must be UL listed In addition the modem must have the appropriate telecommunications safety and EMC approvals for the region in which it is sold Peripheral Storage Devices must be a UL recognized or UL listed accessory and TUV or VDE licensed Total server configuration is not to exceed the maximum loading conditions of the power supply Intel Server Chassis SC5400 User s Guide 81 End of Life Product Recycling Product recycling and end of life take back systems and requiremen
111. s la terre Intel Server Chassis SC5400 User s Guide 101 Avertissements sur l acces au systeme Attention Pour viter de vous blesser ou d endommager votre quipement les consignes de s curit suivantes s appliquent chaque fois que vous acc dez l int rieur du produit Mettez hors tension tous les p riph riques connect s ce produit e teignez le systeme en appuyant sur le bouton d alimentation D connectez l alimentation secteur en d branchant tous les cordons d alimentation secteur du syst me ou de la prise murale D connectez l ensemble des c bles et lignes de t l communication qui sont connect s au systeme Mettez toutes les vis ou autres attaches de c t lorsque vous retirez les panneaux d acces Une fois que vous avez termine d acceder a l interieur du produit refixez le panneau d acces avec les vis ou attaches d origine N essayez pas d acc der l int rieur du bloc d alimentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou de remplacer tout composant non connectable chaud Lorsque vous remplacez le bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de retirer le bloc du serveur Attention Si le serveur a t utilis les processeurs et dissipateurs de chaleur inst
112. s do not allow limitations on how long an implied warranty lasts so this limitation may not apply to you Limitations of Liability 84 Intel s responsibility under this or any other warranty implied or expressed is limited to repair replacement or refund as set forth above These remedies are the sole and exclusive remedies for any breach of warranty Intel is not responsible for direct special incidental or consequential damages resulting from any breach of warranty under another legal theory including but not limited to lost profits downtime goodwill damage to or replacement of equipment and property and any costs of recovering reprogramming or reproducing any program or data stored in or used with a system containing this product Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This limited warranty gives you specific legal rights and you may also have other rights that vary from jurisdiction to jurisdiction Any and all disputes arising under or related to this Limited Warranty shall be adjudicated in the following forums and governed by the following laws for the United States of America Canada North America and South America the forum shall be Santa Clara California USA and the applicable law shall be that of the State of California USA for the Asia Pacific region the forum shall be Singapore and the a
113. s el ctricas fuego y en el equipo lea este documento y preste atenci n a todos las advertencias d precauciones de esta gu a antes de instalar o mantener el producto de servidor de Intel En el caso de que haya diferencias entre la informaci n para un producto en particular contenida en este documento y la informaci n proporcionada con dicho producto o en el sitio Web la documentaci n del producto es la que prevalece S lo personal t cnico cualificado debe montar y prestar los servicios para el servidor Debe ce irse a las directrices de esta gu a y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los productos Utilice s lo los componentes descritos y homologados que se especifican en esta gu a El uso de otros productos o componentes anular la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y precauciones sobre seguridad Para reducir la posibilidad de que se produzcan lesiones personales o dafios en la propiedad antes de empezar a instalar el producto lea observe y cumpla toda la informaci n e instrucciones de seguridad siguientes Puede que se utilicen los siguientes s mbolos de seguridad en la documentaci n y es posible que aparezcan en el producto o en su embalaje PRECAUCI
114. see letter C If the bezel assembly does not immediately disconnect from the chassis tap the left hand side of the bezel assembly to disengage the bezel hooks on the right hand side of the chassis AF000557 Figure 9 Removing the Front Bezel Intel Server Chassis SC5400 User s Guide Installing the Front Bezel Pedestal Only Caution This step applies to a pedestal configuration chassis only For instructions on installing a bezel in a rack mount configuration refer to the Rack Conversion kit Installation Guide Intel Server Chassis SC5400 1 HPA SND Open the outer bezel door ofthe bezel assembly see letter A in the following figure Remove the filler panels that correspond to installed devices see letter B Close the outer bezel door see letter C Fit the right edge of the bezel assembly against the right side of the chassis Engage the plastic bezel hooks see letter D into the raised metal slots at the chassis edge Rotate the bezel assembly toward the chassis Latch the two plastic tabs see letter E on the left side of the bezel assembly to the chassis e 40 Max AF000558 Figure 10 Installing the Front Bezel Intel Server Chassis SC5400 User s Guide 19 Removing and Installing the Processor and Memory Air Ducts Always operate your server chass
115. ser serviceable parts inside it servicing should be done by technically qualified personnel 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Disconnect all internal power cables from chassis components and server board 5 Remove the eight screws securing the fixed power supply shield to the chassis see letter A in the following figure Remove the fixed power supply see letter B Seen GER SARAS I B ati di AF000957 Figure 57 Removing Fixed Power Supply Insert new fixed power supply 7 Secure the fixed power supply shield to the chassis with the eight screws 8 Connect the P1 P14 and P16 cables to the server board See the Intel server board Quick Start User Guide or User Guide for connection locations 9 Reconnect power cables to other chassis components as appropriate 10 Install the chassis cover For instructions see Installing the Chassis Cover on page 17 11 Plug all peripheral devices and the AC power cable into the server 12 Power up the server Intel Server Chassis SC5400 User s Guide 53 Replacing the Power Distribution Board Warning Hazardous voltage current and energy levels are present inside the power supply There are no user servic
116. ses i i ne E EAEE CATES 55 Removing Power Distribution Board 56 Securing Power Distribution Board to Power Supply Cage DI Re installing Center Divider i 58 Installing Hot Swap Power Supply into Chassis ppp 58 Intel Server Chassis SC5400 User s Guide List of Tables Table 1 Server Chassis Features BASE SKU serene 2 Table 2 Server Chassis Features BRP SKU ur 3 Table 3 Server Chassis Features LX SKU nene 4 Table 4 Server Chassis Features LXi SKU Ne 5 Table 5 Front Control Panel LED Descriptions pp 8 Table 6 670 W Power Supply Output Capability pp 63 Table 7 830 W Power Supply Output Capability 4 64 Table 8 Environmental Specifications cinc 64 Table 9 Power Usage Worksheet Nt 65 Table 10 Power Usage Worksheet 2 siii 66 Table 11 Product Regulatory Compliance Markings ppp 72 Table 12 Product Ecology Compliance Markings pp 78 Table 13 Other Marias 80 Intel Server Chassis SC5400 User s Guide xvii xviii Inte amp Server Chassis SC5400 User s Guide 1 Server Chassis Features This chapter briefly describes the main features of the Intel Server Chassis SC5400 This chapter provides a list of the server chassis features as well as diagrams showing the location of important components and connections on the server chassis ot m BO pa 1000000 nee AF000551 Figure 1
117. ses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2006 2007 Intel Corporation All Rights Reserved Intel Server Chassis SC5400 User s Guide Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions See also Intel Server Boards and Server Chassis Safety Information on the Intel Server Deployment Toolkit CD and or at http support intel com support motherboards server sb cs 010770 htm Wichtige Sicherheitshinweise Lesen Sie zun chst s mtliche Warnund Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Sicherheitshinweise zu Intel Serverplatinen und Servergeh usen auf der Intel Server Deployment Toolkit CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de
118. sis SC5400 User s Guide Compliance Regional Description Europe Compliance Reference European Directive 2002 95 EC Restriction of Hazardous Substances ROHS Threshold limits and banned substances are noted below Quantity limit of 0 1 by mass 1000 PPM for Lead Mercury Hexavalent Chromium Polybrominated Biphenyls Diphenyl Ethers PBB PBDE Quantity limit of 0 01 by mass 100 PPM for Cadmium Compliance Reference Marking Example None Required Germany German Green Dot Applied to Retail Packaging Only for Boxed Boards Intel Internal Specification All materials parts and subassemblies must not contain restricted materials as defined in Intel s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers http supplier intel com ehs environmental htm None Required International ISO11469 Plastic parts weighing gt 25gm are intended to be marked with per 15011469 gt PC ABS lt Recycling Markings Fiberboard FB and Cardboard CB are marked with international recycling marks Applied to outer bulk packaging and single package DEG Corrugated Recycles Japan Japan Recycling Applied to Retail Packaging Only for Boxed Boards Intel Server Chassis SC5400 User s Guide 79 Other Markings Table 13 Other Markings Compliance Compliance Reference Description Compliance Roleronea Ma
119. stema se ha dise ado para funcionar en un entorno normal de oficinas Seleccione una ubicaci n que est Limpia seca y libre de macroparticulas en suspensi n en el aire que no sean el polvo habitual de la habitaci n Bien ventilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos e Aislada de campos electromagn ticos producidos por dispositivos el ctricos Enzonas propensas a tormentas el ctricas se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las l neas de telecomunicaciones al m dem durante una tormenta el ctrica e Provista de una toma de corriente alterna correctamente conectada a tierra Provista de espacio suficiente para acceder a los cables de la fuente de alimentaci n ya que constituyen la desconexi n principal de la alimentaci n Manipulaci n del equipo Reduzca el riesgo de dafios personales o en el equipo Respete los requisitos de sanidad y seguridad laborales de su pa s cuando traslade y levante el equipo Utilice medios mec nicos u otros que sean adecuados al trasladar o levantar el equipo Para que el peso sea menor para manipularlo con m s facilidad extraiga los componentes que sean de f cil extracci n 106 Inte amp Server Chassis SC5400 User s Guide Advertencias de alimentacion y electricas Precaucion EI boton de encendido indicado con la mar
120. system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed Intel Server Chassis SC5400 User s Guide 117 After you have completed the six SAFETY steps above you can remove the system covers To do this 1 Unlock and remove the padlock from the back of the system if a padlock has been installed 2 Remove and save all screws from the covers 3 Remove the cover s For proper cooling and airflow always reinstall the chassis covers before turning on the system Operating the system without the covers in place can damage system parts To install the covers 1 Check first to make sure you have not left loose tools or parts inside the system 2 Check that cables add in boards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to the system to prevent unauthorized access inside the system 5 Connect all external cables and the AC power cord s to the system A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer
121. t plug component When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing the power supply from the server If the server has been running any installed processor s and heat sink s may be hot Unless you are adding or removing a hot plug component allow the system to cool before opening the covers To avoid the possibility of coming into contact with hot component s during a hot plug installation be careful when removing or installing the hot plug component s To avoid injury do not contact moving fan blades If your system is supplied with a guard over the fan do not operate the system without the fan guard in place Rack Mount Warnings 90 The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it The equipment rack must be installed according to the rack manufacturer s instructions Install equipment in the rack from the bottom up with the heaviest equipment at the bottom of the rack Extend only one piece of equipment from the rack at a time You are responsible for installing a main power disconnect for the entire rack unit This main disconnect must be readily accessible and it must be labeled as controlling power to the entire unit not just to the server s To avoid risk of potential electric shock a proper safety ground must be implemented for the rack and each piece of equ
122. t secure the plastic air baffle to the drive carrier Remove the plastic air baffle AF000590 Figure 46 Removing Plastic Air Baffle 4 Secure the hard drive to the drive carrier using the four screws that were formerly attached to the plastic air baffle Ensure that the connector end of the hard drive is facing the back of the drive carrier The label side of the hard drive should be facing up in the drive carrier 44 Intel Server Chassis SC5400 User s Guide AF000591 Figure 47 Securing Hard Drive to Drive Carrier 5 With the black lever open insert the drive carrier into the drive cage Once inserted rotate the black lever upwards to latch the drive carrier into position AF000592 Figure 48 Inserting Drive Carrier into Hot Swap Cage Removing and Installing PCI Add in Board s Removing PCI Add in Board s Caution When removing a full length add in card you must pull back the latch on the plastic card guide at the front of the chassis to release the card from the card guide 1 Observe the safety and ESD precautions at the beginning of this book 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the chassis cover For instructions see Removing the Chassis Cover on page 16 4 Remove the front bezel if it is installed For instructions see Removing and Installing the Front Bezel on page 18 Remove any cables attached to the add in card i
123. tamente 3 Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente 4 Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l accesso non autorizzato al sistema 5 Ricollegare tutti i cavi esterni e le prolunghe AC del sistema Se il sistema stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore Per disfarsi delle pile usate seguire le istruzioni del produttore Il sistema progettato per funzionare in un ambiente di lavoro tipo Scegliere una postazione che sia Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente Ben ventilata e lontana da fonti di calore compresa la luce solare diretta Al riparo da urti e lontana da fonti di vibrazione e Isolata dai forti campi magnetici prodotti da dispositivi elettrici In aree soggette a temporali consigliabile collegare il sistema ad un limitatore di corrente In caso di temporali scollegare le linee di comunicazione dal modem e Dotata di una presa a muro correttamente installata
124. the six drive fixed drive bay An optional four drive fixed drive bay for cabled drives is available No tools are required to replace the fixed drive bays Optional four drive and six drive SAS SATA and SCSI hot swap drive bays are available For instructions on installing hard drives see Removing and Installing Hot Swap Drive s on page 42 Drives can consume up to 17 watts of power each Drives must be specified to run at a maximum ambient temperature of 45C The Intel Server Chassis SC5400 does not support all SAS SATA or SCSI hard drives See Additional Information and Software on page ix for an Internet link to a list of supported hardware Floppy CD ROM DVD ROM Slimline Carriers Note For installation instructions on installing a floppy drive see Installing and Removing a Slimline USB Floppy CD DVD Combo Kit on page 26 For installation instructions on installing a CD ROM drive or DVD ROM drive see Removing and Installing a DVD or CD ROM Drive on page 27 To use one of the drives provided by Intel use the following order codes Slimline CD ROM Drive AXXSCD Slimline DVD CDR Drive AXXDVDCDR Slimline Floppy Drive AXXCDUSBFDBRK The Intel Server Chassis SC5400 does not support all slimline floppy CD ROM or DVD ROM hard drives See Additional Information and Software on page ix for an Internet link to a list of supported hardware Intel provides accessory kits for these drives
125. tive Product Nt 85 Appendix D Safety Information scaricare 87 Eni lish 30 87 Server Safety Information asd apes PP 87 Safety Warnings and Cautions i 87 Intended Application Uses css acti 88 PP 88 Equipment Handling Practices siria ra 88 Power and Electrical Warnings coccoccconnnnoncconinonocnnnnnncnnnnnnnnnnnnnnn nn emen 89 System Access Wamings une 90 Rack Mount Warnings ei m 90 Electrostatic Discharge ESD sse 91 ME 91 Sicherheitshinweise f r den Server ii 93 Sicherheitshinweise und Vorsichtsma nahmen pp 93 Zielbenutzer der Anwendung pp 94 Standortauswahl pp 94 Handhabung von Ger ten ee eu 94 Warnungen zu Netzspannung und Elektrizit t pp 95 Warnhinweise f r den Systemzugang pp 96 Warnhinweise f r Racks cm 97 Intel Server Chassis SC5400 User s Guide xiii Elektrostatische Entladungen ESD pp 97 Andere Gefahren s r 98 Free E E TU RE ER 99 Consignes de s curit sur le serveur i 99 S curit avertissements et mises en garde reren 99 Domaines d utilisation Prevus nn ar 100 S lection dun emplacement pp 100 Pratiques de manipulation de l quipement 100 Alimentation et avertissements en mati re d lectricit pp 101 Avertissements sur l acc s au syst me i 102 Avertissements sur le montage en rack 102 D charges lectrostatiques E
126. trom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Intel Server Chassis SC5400 User s Guide 119 SICHERHEISMASSNAHMEN Immer wenn Sie die Gehauseabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripheriegerate aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den StromanschluBstecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD Uber blanke Metallstellen
127. ts cies ccena senti euet hs eg uia iaia 6 Front Control Panel d en 7 Intel Local Control Panel EE ia 9 Back Panel FeatyreS si i este 10 Peripheral DOViCGS cn nn ernennen edit 11 Standard and Optional Hot swap Drive Bays pp 12 Floppy CD ROM DVD ROM Slimline Carriers nn nenennnnnnnnnnnnnnnnne 12 Intel Remote Management Module ana eer ere en ene ee 13 Rack mounted Sysiems rca ea 13 Chapter 2 Hardware Installations and Upgrades 15 Before You BOI ae iris 15 Tools and Supplies Needed pp 15 System RETSTENCES 000i ee 15 Removing and Installing the Chassis Cover i 16 Removing the Chassis Cover u a 16 Installing the Chassis Cover sele 17 Removing and Installing the Front Bezel pp 18 Removing the Bezel Assembly Pedestal Only pp 18 Installing the Front Bezel Pedestal Only pp 19 Removing and Installing the Processor and Memory Air Ducts pp 20 Removing the Processor and Memory Air Ducts ern 20 Installing the Processor and Memory Air Ducts pp 21 Replacing a Fixed Fan Intel Server Chassis SC5400Base SC5400BRP only 23 Removing and Installing Hot Swap Fans Intel Server Chassis SC5400LX or Intel Server Chassis SC5400 User s Guide xi SC5400LXi Only oc ee entre 24 Removing Hot Swap Fans nee ea as 24 Installing Hot Swap Fans ae ea 25 Installing and Removing a Slimline USB Floppy CD DVD Combo Kit 26 Installin
128. ts vary by country Contact the retailer or distributor of this product for information about product recycling and or take back 82 Intel Server Chassis SC5400 User s Guide Appendix E Installation Assembly Safety Instructions English The power supply in this product contains no user serviceable parts Refer servicing only to qualified personnel Do not attempt to modify or use the supplied AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off system AC power To remove AC power from the system you must unplug each AC power cord from the wall outlet or power supply The power cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system 2 Turn off the system by pressing the power button 3 Unplug all AC power cords from the system or from wall outlets 4 Label and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the
129. u de poussi re en suspension sauf la poussi re normale i Bien a r et loin des sources de chaleur y compris du soleil direct e A l abri des chocs et des sources de vibrations sol de forts champs lectromagn tiques g en r s par des appareils lectriques Dans les r gions sujettes aux orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale correctement mise la terre e Suffisamment spacieux pour vous permettre d acc der aux c bles d alimentation ceux ci tant le seul moyen de mettre le systeme hors tension Intel Server Chassis SC5400 User s Guide 123 Espanol El usuario debe abstenerse de manipular los componentes de la fuente de alimentaci n de este producto cuya reparaci n debe dejarse exclusivamente en manos de personal t cnico especializado Puede que este producto disponga de m s de una fuente de alimentaci n No intente modificar ni usar el cable de alimentaci n de corriente alterna si no corresponde exactamente con el tipo requerido El n mero de cables suministrados se corresponden con el n mero de fuentes de alimentaci n de corriente alterna que tenga el producto N tese que el interruptor activado desactivado en el panel frontal no desconecta la corriente alterna del sistema Para desconectarla
130. ury or property damage before you begin installing the product read observe and adhere to all of the following safety instructions and information The following safety symbols may be used throughout the documentation and may be marked on the product and or the product packaging CAUTION Indicates the presence of a hazard that may cause minor personal injury or property damage if the CAUTION is ignored WARNING Indicates the presence of a hazard that may result in serious personal injury if the WARNING is ignored Indicates potential hazard if indicated information is ignored Indicates shock hazards that result in serious injury or death if safety A instructions are not followed Intel Server Chassis SC5400 User s Guide 87 Indicates hot components or surfaces Indicates do not touch fan blades may result in injury geb Indicates to unplug all AC power cord s to disconnect AC power Please recycle battery J G9 Intended Application Uses This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial residential alarm systems and test equipment other than an ITE application may require further evaluation Site Selection The system is designed to operate in a typica
131. workmanship and will substantially conform to Intel s publicly available specifications for a period of three 3 years after the date the Product was purchased from an Intel authorized distributor Software of any kind delivered with or as part of products is expressly provided as is unless specifically provided for otherwise in any software license accompanying the software If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty Intel at its option will REPAIR the Product by means of hardware and or software OR REPLACE the Product with another Product OR REFUND the then current value of the Product if Intel is unable to repair or replace the Product If such Product is defective transportation charges for the return of Product to buyer within the USA will be paid by Intel For all other locations the warranty excludes all costs of shipping customs clearance and other related charges Intel will have a reasonable time to make repairs or to replace Product or to refund the then current value of the Product In no event will Intel be liable for any other costs associated with the replacement or repair of Product including labor installation or other costs incurred by buyer and in particular any costs relating to the removal or replacement of any product soldered or otherwise permanently affixed to any printed circuit boa