Home

Dodge 2004 PL Neon Automobile User Manual

image

Contents

1. When the CM61 NG is in AUTO position display will show AUTO the temperature can be adjusted temporarily by pressing TEMP or w The temperature will return to the program at the next temperature change time How do I check the programmed temperature In normal operation the temperature displayed is the actual room temperature To check the programmed temperature press ii and the display will show the programmed temperature with the two small arrows How do I set one temperature for the whole day To operate as a simple thermostat with one temperature throughout the day press MAN Adjust the manual temperature by pressing TEMP a or w The manual temperature can be set anywhere from 5 C to 30 C in 0 5 C steps lam going on holiday for a few days How do save energy but ensure that the house is warm when I return 1 Make sure the CM61NG is in AUTO or MAN mode 2 Press I HOLIDAY to display the holiday days counter and temperature 3 Press or to set the holiday time 1 99 days 4 Press TEMP or w to set the holiday temperature 5 C 30 C The unit will control to the new temperature for the set number of days holiday At midnight the holiday counter will be reduced by one until the selected number of days have passed The unit will then return to normal control as set by the MAN or AUTO position To cancel the HOLIDAY setting press the I I button a second time How can switch the H
2. Buttons Mae increase WW decrease Automatic Function Battery Compartment Button Manual Function Off Button Holiday Button Program Button Buttons How do I set the time The time can be set with the CM61 NG in the AUTO MAN or OFF operating modes Press or until the correct time is displayed Each button press will change the time by one minute Holding the button down for a few seconds will change the time slowly at first then quickly Make sure AM or PM is correct ie ae NN on AUTO How do I get started with the built in tempera ture program Press the AUTO button The CM61NG will now control your heating using the built in temperature program Daily Program 1 2 3 4 5 6 Time 06 30 08 00 12 00 2 00 6 00 10 30 Temperature 21 C 18 C 21 C 18 C 21 C 16 C How do I set my own daily temperature pro gram 1 Press PROG 1 The first temperature change time and tempera ture level will flash to indicate they can be changed the two small arrows are displayed only when the programmed temperature level is shown FUL a E A Ve e 2 3 4 5 6 2 Press or to adjust the first temperature change time Holding the button down will change the time quickly The change time can be set in 10 minute steps from 03 00 in the morning The change time can be adjusted up to 02 50 on the next morning so you can maintain the evening temperature after midnight Note
3. daily independent temperature levels let you set any 6 temperatures from 5 to 30 C to match your daily lifestyle Holiday button saves energy by letting you reduce the tempera ture for 1 to 99 days while you are on holiday returning to normal operation on the day you return Memory holds the user program indefinitely so that it is never lost even if you take the batteries out What is Optimum Start Instead of switching on the heating at the set time every day the CM61NG will delay the start time to the latest possible moment so that unnecessary heating is avoided All you have to do is set the time when you want comfort temperature and the CM61 NG will then decide when to turn the heating on thereby ensuring your comfort 42010475 003 R1 How do install the batteries 1 Lift up the front flap to reveal the battery compartment Open the battery compartment by inserting a coin underneath the bottom right edge of the flap and lift out 2 Pull the paper tab out to activate the 2 AA LR6 Alkaline Batteries included and push the battery compartment firmly back into the front of the unit After a pause the unit will now display information gt CM61NG Controls Display Layout The diagram below details the key button functions and display information Battery Low Time Display Heat Demand Temperature Indicator Indicator Display Information Enquiry Button Time Change Buttons Temperature Change
4. value between 0 100 The relay box will adjust the boiler on time to meet this requirement That is why the heating will be off sometimes even if the flame symbol is displayed To check if RF system is communicating properly press the TEMPerature UP button to increase the set temperature a few degrees above the current temperature The heating should come on after a few seconds Switch the boiler on Call electrical installer to check the boiler and relay box power supply as well as the connection between the boiler and the relay box Hook the room unit back on the wall bracket or replace the room unit on the table stand to the position where RF communication was reliable Call installer NOTE You can control the boiler manually when the RF communica tion is lost Press the HC60NG push button to switch the boiler on and off When the green LED is on the boiler is on Call installer Call installer Remove the battery compartment and re insert it If the spanner symbol does not clear itself in a few minutes call the installer RECOMMENDED This product and its associated documentation and packaging are protected by various intellectual property rights belonging to Honeywell Inc and its subsidiaries and existing under the laws of the UK and other countries These intellectual and property rights may include patent applications registered designs unregistered designs registered trade marks unregistered trade m
5. If you attempt to move a change time past the next change time both times will be moved 3 Press TEMP or w to adjust the first temperature level Holding the button down will change the temperature quickly The temperature can be set in 0 5 C steps from 5 C to 30 C 4 Press PROG 2 to display the second temperature change time and temperature level Set these by pressing or and TEMP or w 5 The remaining temperature changes can be displayed by pressing PROG buttons 3 4 5 and 6 and adjusted by using or and TEMP amp or w If you don t want to use all the temperature change times 2 3 4 5 or 6 refer to the section What if don t want to use all 6 temperature change times 6 Press AUTO when you have completed your programming The CM61NG will now control the room temperature to match your program What if don t want to use all 6 temperature change times The built in program uses 6 temperature change times as indicated by the numbers 1 2 3 4 5 and 6 on the display Unwanted change times can be deleted by holding the appropriate PROG buttons 2 3 4 5 or 6 down for a few seconds The change time will be removed and the display will show dashes instead of a time temperature display Deleted temperature change times can be brought back by again pressing the appropriate program button 2 3 4 5 or 6 for a few seconds Can I change the programmed temperature for a short time
6. What if something happens to my heating system How can I check that the gt CMG61NG is working See the troubleshooting guide below If you need assistance after this call your installer T CM61NG Trouble Shooting Guide Symptom Blank display Display shows flashing battery symbol Display shows flame symbol but heating does not switch on Display works but heating does not switch on HC60NG LEDs are off or green one is on HC60NG red LED is constantly on or flashing Heating switches on or off too slowly or too quickly Temperature swings between too hot and too cold Display show spanner symbol Warning Possible Cause No batteries Wrong battery orientation Exhausted batteries Improper battery compartment insertion Batteries need replacing The heating is not required at this moment Boiler switched off Wrong electrical connection RF communication lost due to the wrong location of the room unit RF communication fault 7 CM61NG not set correctly for your system 7 CM61NG not set correctly for your system Fault in the CM61NG Remedy Check that the batteries are in the battery compartment and that the paper tab has been pulled out Check that the batteries have been installed in the correct orientation Replace batteries Remove battery compartment and re insert Change batteries as described previously The heat demand is sent to the relay box as a
7. arks and copyrights and also include the following UK registra tion rights UK patent application number 98062207 8 UK registered design numbers 2073334 2073340 and 2073343 Honeywell Control Systems Ltd Arlington Business Park Bracknell Berkshire RG12 1EB Tel 01344 656000 Honeywell www honeywell com uk homes htm Honeywell AABN RF Programmable Thermostat What is an RF Programmable Thermostat A Honeywell Radio Frequency RF programmable thermostat is a thermostat that controls your heating system so that you can have comfortable temperatures when you are at home and energy savings when you are out With RF communication there is no need to provide a wired connection between thermostat and boiler The G CM61NG can therefore be installed without disrupting your room decor These instructions explain how to program and operate your CM61NG to get the most comfort at the least cost What will the CM61NG Programmable Thermo stat do for me Wireless connection to the boiler allows you to mount the CM61NG in your room without disrupting the decor Armchair programming lets you set up your CM61 NG while resting comfortably in your armchair Optimum Start means that the CM61 NG will switch on your heating system so that your desired comfort temperature is reached at the programmed time thus avoiding unnecessary boiler firing Attractive slim styling compatible with any room decor 6
8. eating on and off manually To switch the boiler ON or OFF 1 Press the MAN button 2 Press TEMP amp or w until the boiler switches ON or OFF How can I switch the ome NG off Press the OFF button The unit will now control at 5 C How do I know when the batteries need to be changed and how do I do this Your CME 1 NG has built in electronics that constantly monitor the battery power level With no accessory fitted the batteries should last about 2 years When the batteries need replacing a flashing symbol will be displayed To change the batteries 1 Lift up the front flap to reveal the battery compartment Open the battery compartment by inserting a coin underneath the bottom right edge of the flap and lift out 2 Replace the used batteries with 2 new AA LR6 Alkaline Batteries Duracell are recommended and push the battery compartment firmly back into the front of the unit RESPECT YOUR ENVIRONMENT Take care to dispose of used batteries carefully The CM61 NG has a permanent memory to keep your program settings While you change the batteries you should never need to reprogram However if you take more than one minute to change them you may need to correct the time by pressing or Can use my Omer NG to control my air condi tioning system Yes Please refer to your installer for more information How do I remove the ome NG from the wall bracket After programming is fini
9. must be located in a location where reliable communication was proven Advise your installer where you would like to position the room unit and they will check if the RF communication is reliable in the selected location s
10. shed always replace the CM61NG back on the wall bracket HC60 Relay Box Controls Layout The relay box will normally be found mounted close to the boiler Push button and relay status LED s What does it mean when the HC60NG relay box green LED is ON The green LED indicates normal operation of the radio frequency system When the green LED is ON the boiler is also ON When the LED is OFF the boiler is OFF When do I need to use the push button You should use the push button to control your boiler only when the RF communication is lost see the CM61NG Trouble Shooting Guide What other accessories can buy for the omer NG Automatic Time Setting ATS Add On Module Part No Q6667B1015 The ATS module picks up a daily time signal om a transmitter in Central Europe and corrects the time on the CM61NG display So e You never need to set or adjust the time e There is no need to adjust the unit by 1 hour in summer winter since the unit does this automatically e Your CM61NG is the most accurate clock in your home so you can use this information to set up all your other clocks Not available in all Geographic Regions depending on transmitter range and home location Table stand for the room unit Part No F42010248 002 If you do not want to mount the room unit on the wall you can use optional table stand ask you installer for details Note The room unit

Download Pdf Manuals

image

Related Search

Related Contents

Janome 1100D Sewing Machine User Manual  HP SureStore HD Server 4000 (J3290A#ABF) 9 GB Hard Drive Array  HAMGSM133 - Velleman  新製品 - 平沼産業  Notice utilisateur et mise en service Profil 960 NTP  Hydro-Probe II Guía del Usuario  Untitled  Installation guide  - Arms Reach  Tecumseh SIERRA17-0982Y3XA Technical Data Sheet  