Home
DeVilbiss FA752-3 Air Compressor User Manual
Contents
1. COMPRESSOR ON A PROTECTIVE MAT WHEN TRANSPORTING TO PROTECT AGAINST DAMAGE TO VEHICLE FROM LEAKS REMOVE COMPRESSOR FROM VEHICLE IMMEDIATELY UPON ARRIVAL AT YOUR DESTINATION GLOSSARY SCFM Standard Cubic Feet per Minute a unit of measurement of air delivery U L Listed Products with the U L mark are listed by Underwriters Laboratories Inc U L Samples of these products have been evaluated by U L and meet the PSIG or PSI Pounds per square inch gauge applicable U L Standards for Safety DUTY CYCLE hour is considered misuse because the air compressor 15 undersized for the required air demand Maximum com pressor pumping time per hour is 30 minutes All DeVilbiss Air Power manufactured air compressors should be operated on not more than 50 duty cycle This means an air compressor that pumps more than 50 ofone DESCRIPTION OF OPERATION Air Compressor Pump To compress air the piston moves up and down in the cylinder On the downstroke air is drawn in through the air intake muffler valves The exhaust valve remains closed On the upstroke of the piston air is compressed The intake valves close and compressed air is forced out through the exhaust valve and then through the air hose Adjustable Pressure Valve The pressure valve controls the amount of pressure going from the air compressor to the accessory The pressure adjusting valve can be used to set approximate pressure between 10 and
2. REPAIRS PROBLEM CAUSE CORRECTION Air Leaks Hose fitting loose Tighten fitting Compressor is not delivering Prolonged excessive use of air Decrease the amountofair usage Yourcompres enough air sor is not large enough for the air requirement Hole in hose Replace the hose Air leaks Tighten fittings Motor will not run Fuse blown circuit breaker tripped 1 Check fuse box for blown fuse and replace as necesssary Reset circuit breaker Do not use afuse or circuit breaker with higher rating than that specified for your particular branch circuit 2 Check for proper fuse You should be using a Quick Acting fuse Check for low voltage problem 4 Check the extension cord 5 Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Extension cord is wrong length or Check the extension cord gauge Loose electrical connections Check wiring connection inside terminal box Faulty motor Have checked at a local Service Center High discharge pressure Adjustable pressure valve notfunc Cannot be adjusted lower tioning AWARNING RISK OF BURSTING DO NOT OPERATE THE COMPRESSOR IF THIS PROBLEM EXISTS ADJ USTABLE PRESSURE VALVE MUST BE REPLACED 11 MGP FA752 3A OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR MODEL NOS FA752 3 FAC752 3 For Home Use Only Call our Toll Free Number 1 800 888 2468 Ext 2 then
3. 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model number of your product Part number and description of the item you wish to purchase WARRANTY This product is covered by the DeVilbiss one year limited warranty The warranty can be found in the General Manual or is available upon request Attach Sales Receipt Here Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work DeVilbiss Company Air Power 213 Industrial Dr J ackson TN 38301 9615 MGP FA752 3A
4. 125 P S I 125 P S I is the highest pressure this compressor will deliver It is normal for the adjustable pressure valve to release air during operation AWARNING ALWAYS SET THE PRESSURE VALVE AT OR BELOW THE REQUIRED PRESSURE FOR THE ACCESSORY BEING USED BEFORE STARTING YOUR COMPRES SOR FOR INFLATION OR OTHER USES REQUIRING ACCURATE PRESSURE USE A PRESSURE GAUGE 7 ENG Accumulator Tank Your accumulator tank is equipped with a relief valve to prevent an over pressure condition in the tank This 2 gallon tank is not designed to store air but rather to provide the additional volume of compressed air necessary to operate a wide variety of air tools When starting your compressor attach the tool to the hose set the pressure adjusting valve at the required pressure wait a few moments until the tank fills with air You will know the tank is filled when you hear air bleeding through the pressure adjusting valve Depending on the type and size of tool being used you will occasionally need to wait for the tank to refill before continuing When you are or changing tools turn the compressor switch off and pressure adjusting valve to 10 PSI and wait for the tank to discharge completely MGP FA752 3A INSTALLATION AND BREAK IN PROCEDURES Location of the Air Compressor Your compressor comes to you completely assembled and ready for use Operate the air compressor in a dry clean cool and
5. CAUSE PROPERTY DAMAGE SERIOUS INJ URY WHAT CAN HAPPEN 1 FAILURE TO PROPERLY DRAIN CONDENSE FROM THE TANK CAUSING RUST AND THIN STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK D WATER NING OF THE 3 UNAUTHORIZED MODIFICATIONS TO THE UNLOADER VALVE SAFETY VALVE OR ANY OTHER COMPONENTS WHICH CONTROL TANK PRESSURE 4 EXCESSIVE VIBRATION CAN WEAKEN THE AIR TANK AND CAUSE RUPTURE OR EXPLOSION ATTACHMENTS amp ACCESSORIES EXCEEDING THE PRESSURE RATING OF AIR TOOLS SPRAY GUNS AIR OPERATED ACCESSORIES TIRES AND OTHER INFLATABLES CAN CAUSE THEM TO EXPLODE OR FLY APART AND COULD RESULT IN SERIOUS INJURY MGP FA752 3A 4 ENG HOW TO PREVENT IT DRAIN TANK DAILY OR AFTER EACH USE IF TANK DEVEL OPS A LEAK REPLACE IT IMMEDIATELY WITH A NEW TANK OR REPLACE THE ENTIRE COMPESSOR NEVER DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE USTMENTS OR PARTS ALTER THE FACTORY SET FOR ESSENTIAL CONTROL OF AIR PRESSURE YOU MUST INSTALL A PRESSURE REGULATOR AND PRESSURE GAUGE TO THE AIR OUTLET OF YOUR COMPRESSOR FOLLOW THE EQUIPMENT MANUFACTURERS RECOMMENDATION AND NEVER EXCEED THE MAXIMUM ALLOWABLE PRESSURE RATING OF ATTACHMENTS NEVER USE COMPRESSOR TO INFLATE SMALL LOW PRESSURE OBJECTS SUCH AS CHILDREN S TOYS FOOTBALLS BASKETBALLS ETC HAZARD RISK
6. FROM FLYING OBJ ECTS WHAT CAN HAPPEN HOW PREVENT IT THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE ALWAYS WEAR ANSI Z87 1 APPROVED SAFETY GLASSES DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT CHIPS WITH SIDE SHIELDS WHEN USING THE COMPRESSOR LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED NEVER POINT ANY NOZZLE OR SPRAYER TOWARD ANY RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY GOETHE ROUT OH AT GT e O OB ALWAYS TURN THE COMPRESSOR OFF AND BLEED PRES SURE FROM THE AIR HOSE AND TANK BEFORE ATTEMPTING MAINTENANCE ATTACHING TOOLS OR ACCESSORIES RISK TO BREATHING WHAT CAN HAPPEN HOW TO PREVENT IT THE COMPRESSED AIR FROM YOUR COMPRESSOR IS NOT ALWAYS OPERATE AIR COMPRESSOR OUTSIDE IN A CLEAN SAFE FOR BREATHING THE AIR STREAM MAY CONTAIN WELL VENTILATED AREA AVOID ENCLOSED AREAS SUCH AS CARBON MONOXIDE TOXIC VAPORS OR SOLID PARTICLES GARAGES BASEMENTS STORAGE SHEDS WHICH LACK A FROM THE TANK STEADY EXCHANGE OF AIR KEEP CHILDREN PETS AND OTHERS AWAY FROM AREA OF OPERATION NEVER INHALE AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS WORK IN AN AREA WITH GOOD CROSS VENTILATION READ PAINT REMOVER INSECTICIDES WEED KILLERS CONTAIN AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON HARMFUL VAPORS AND POISONS THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL YOU ARE SPRAYING USE A NIOSH MSHA APPROVED RESPIRAT
7. OMPRESSOR IS AVAILABLE AT SEARS ACAUTION Do not allow hose to become kinked or pinched atany time This is importantto avoid damage to your compressor and to maintain pressure adjusting valve control OPERATING PROCEDURES 1 Before plugging the air set adjust able pressure valve to 10 PSI Make sure the ON OFF switch is in the OFF position Connect the air tool or accessory to the air hose Tighten securely Plug the power cord into the grounded outlet Start the compressor by setting the ON OFF switch to the ON position AWARNING TOO MUCH AIR PRESSURE COULD CAUSE AN AIR TOOL OR VEHICLE TIRE TO RUPTURE OR EXPLODE CAREFULLY FOLLOW STEPS 5 AND 6 EACH TIME YOU USE YOUR COMPRESSOR 5 Check the manufacturer s maximum pressure rating for the air tool accessory or vehicle tire being used The air compressor outlet pressure must never ex ceed the maximum pressure rating 6 Slowly increase the pressure setting of the adjustable pressure valve You should be able to hear and feel air pressure being relieved by the adjustable pressure valve If pressure is not being relieved turn the air compressor off immediately The pressure valve must be replaced ACAUTION Compressed air from the outfit may contain water condensation Do not spray unfiltered air at an item that could be damaged by moisture Some air operated tools or devices may require filtered air R
8. OR DESIGNED FOR USE WITH YOUR SPECIFIC APPLICATION RISK OF ELECTRICAL SHOCK 2 ull ir WHAT CAN HAPPEN HOW TO PREVENT IT YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY LIKE ANY NEVER OPERATE THE COMPRESSOR OUTDOORS WHEN IT IS OTHER ELECTRICALLY POWERED DEVICE IF IT IS NOT USED RAINING OR IN WET CONDITIONS PROPERLY IT MAY CAUSE ELECTRIC SHOCK NEVER OPERATE COMPRESSOR WITH COVER COMPONENTS REMOVED OR DAMAGED REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN ANY ELECTRICAL WIRING OR REPAIRS REQUIRED ON THIS RESULT IN SERIOUS INJ URY OR DEATH BY ELECTROCU PRODUCT SHOULD BE PERFORMED BY AUTHORIZED TION SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH ELECTRICAL GROUNDING FAILURE TO PROVIDE ADEQUATE THE COMPRESSOR IS CONNECTED PROVIDES PROPER GROUNDING TO THIS PRODUCT COULD RESULT IN SERIOUS ELECTRICAL GROUNDING CORRECT VOLTAGE AND INJ URY OR DEATH FROM ELECTROCUTION SEE GROUND ADEQUATE FUSE PROTECTION ING INSTRUCTIONS 5 ENG MGP FA752 3A HAZARD RISK FROM MOVING PARTS WHAT MOVING PARTS SUCH AS THE PULLEY FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COM PRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY RISK OF BURN
9. OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR MODEL NOS 752 3 752 3 For Home Use Only SPECIFICATION CHART Model No FA752 3 FAC752 3 Horsepower 3 4 SCFM 40 psig 3 0 3 0 SCFM 90 psig 2 2 2 2 Displacement CFM 4 0 4 0 Bore 1 3 4 1 3 4 stroke 1 1 4 1 1 4 Voltage Single Phase 120 120 Minimum Branch Circuit Requirement 15 AMPS 15 AMPS Fuse Type Quick Acting Quick Acting Tank Size 2 Gallon 2 Gallon circuit breaker is preferred Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on If the air compressor is connected to a circuit protected by fuses use quick acting fuses SAFETY GUIDELINES DEFINITIONS This manual contains information that is important for you to know and understand This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the symbols to the right Please read the manual and pay attention to these sections ADANGER ACAUTION DANGER indicates an imminently hazardous situation which if CAUTION indicates a potentially hazardous situation which if not avoided will result in death or serious injury not avoided may result in minor or moderate injury AWARNING WARNING indicates a potentially hazardous situation which if CAUTION used without the safety alert symbol indicates a not avoided could result in death of serious injury potentiall
10. S WHAT TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES CAN RESULT IN SERIOUS BURNS RISK OF FALLING WHAT CAN HAPPEN A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COM PRESSOR AND COULD RESULT IN SERIOUS INJ URY OR DEATH TO THE OPERATOR RISK OF PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR Fire Inhalation Damage to Vehicle Surfaces WHAT CAN HAPPEN OIL CAN LEAK OR SPILL AND COULD RESULT IN FIRE OR BREATHING HAZARD SERIOUS INJ URY OR DEATH CAN RESULT OIL LEAKS WILL DAMAGE CARPET PAINT OR OTHER SURFACES IN VEHICLES OR TRAILERS ESW 99 9 26 99 MGP FA752 3A 6 ENG HOW TO PREVENT IT NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAMAGED OR REMOVED ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSON NEL AIA HOW PREVENT IT NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRES SOR DURING OR IMMEDIATELY AFTER OPERATION COM PRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL HOW TO PREVENT IT ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT ACCIDENTAL MOVEMENT OF THE UNIT NEVER OPERATE COMPRESSOR ON A ROOF OR OTHER ELEVATED POSITION USE ADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS HOW TO PREVENT IT ALWAYS PLACE
11. TY DAMAGE READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT HAZARD RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS THEY MAY IGNITE CAUSING FIRE OR EXPLOSION RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE FIRE UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT IN PERSONAL INJ URY OR PROPERTY DAMAGE RISK OF BURSTING HOW TO PREVENT IT ALWAYS OPERATE THE COMPRESSOR IN A WELL VENTILATED AREA FREE OF COMBUSTIBLE MATERIALS GASOLINE OR SOLVENT VAPORS IF SPRAYING FLAMMABLE MATERIALS LOCATE COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAY AREA AN ADDITIONAL LENGTH OF HOSE MAY BE REQUIRED STORE FLAMMABLE MATERIALS IN A SECURE LOCATION AWAY FROM COMPRESSOR NEVER PLACE OBJECTS AGAINST OR ON TOP OF COMPRESSOR OPERATE COMPRESSOR IN AN OPEN AREA AT LEAST 12 INCHES AWAY FROM ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTI LATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AREA ALWAYS REMAIN IN ATTENDANCE WITH THE PRODUCT WHEN IT IS OPERATING AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT VIOLENT TANK EXPLOSION AND COULD
12. d is considered misuse because the air compressor is undersized for the required air demand Maximum compressor pumping time per hour is 30 minutes Merchandise sold by DeVilbiss Air Power Manufacturing which has been manufactured by and identified as the product of another company The product manufacturer s warranty will apply Repair and transportation costs of merchandise determined not to be defective Cost associated with assembly required oil adjustments or other installation and start up cost ANY INCIDENTAL INDIRECT OR CONSEQUENTIAL LOSS DAMAGE OR EXPENSE THAT MAY RESULT FROM ANY DEFECT FAILURE OR MALFUNCTION OF THE PRODUCT Somestates do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 1 IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 22 DeVILBISS AIR POWER COMPANY 213 Industrial Drive Jackson TN 38301 9615 Telephone 1 800 888 2468 Ext 2 FAX 1 800 888 9036 Form SP 100 G 9 29 99 3 ENG MGP FA752 3A IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AWARNING IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJ URY AND PROPER
13. e illustration DO NOT USE AN ADAPTER Inspect the plug and cord before each use Do not use if there are signs of damage ADANGER IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK MGP FA752 3A 8 ENG Do not modify the plug that has been provided If it does fit the available outlet the correct outlet should be installed by a qualified electrician If repairing or replacing cord or plug the grounding wire must be kept separate from the current carrying wires Never connect the grounding wire to a flat blade plug terminal The grounding wire has insulation with an outer surface that is green with or without yellow stripes If these grounding instructions not completely understood or if in doubt as to whether the compres sor 15 properly grounded have the installation checked by a qualified electrician 120 Volt Models White Ground 15 ANP PLUG GROUNDED OUTLET OUTLET GROUNDING PIN 120 Volts 15 Amps Air Hose The air hose attached to your comporessor has an integral pressure adjusting valve at the working end of the hose Should service or replacement be required make sure that the pressure adjusting valve is present in the air hose line It is normal for the adjustable pressure valve to release air during operation AWARNING DO NOT REPLACE THE HOSE WITH STAN DARD HOSE THAT IS NOT EQUIPPED WITH THE PRESSURE ADJUSTING VALVE THE APPROPRIATE HOSE ASSEMBLY FOR YOUR C
14. ead the instructions for the air tool or device STORAGE When you have finished using the air compressor 1 2 Set the ON OFF switch to OFF and unplug the cord Relieve all pressure from the air compressor head and air hose by setting the adjustable pressure valve to 10 P S I Drain water from air tank 4 After the water has been drained close the drain cock or drain valve 5 Protectthe electrical cord and air hose from damage by winding them loosely around the air compressor 6 Store the air compressor in a clean and dry location 9 ENG MGP FA752 3A PARTS LIST COMPRESSOR ASSEMBLY ON OFF N TIS NUTSLEEVE ASSEMBLY CROSS PIPE PRESSURE VALVE ASSEMBLY CHUCK PARTS ABAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER Safety Valve TIA 4150 Drain Vale uu l ay asan cae SS 2707 Pressure Valve Assembly CAC 4324 OQ LG TUDO CAC 1289 Connecting Rod Kit KK 4964 Bee SS 4929 Ori uama rna amam K 0387 Nut Sleeve SSP 473 lial are tee E SSP 3305 NI PNG SSH 8 10 MGP FA752 3A TROUBLESHOOTING GUIDE VOLTAGE SOURCES MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR PERSONAL INJ URY CAN OCCUR UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY
15. k Cover LIMITED WARRANTY ONE YEAR FROM DATE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser initial user Products covered under this warranty include air compressors tools accessories service parts pressure washers and generators used in consumer applications i e personal residential household usage only Air compressors tools accessories service parts pressure washers and generators used in commercial applications income producing are covered by a 90 day warranty DeVilbiss Air Power Manufacturing will repair or replace at DeVilbiss option products or components which have failed within the warranty period Repair or replacement and service calls on 60 and 80 gallon air compressors will be handled by Authorized Warranty Service Centers and will be scheduled and serviced according to the normal work flow and business hours at the service center location and depending on the availability of replacement parts All decisions of DeVilbiss Air Power Company Manufacturing with regard to this policy shall be final This warranty gives you specific legal rights and you may also have other rights which vary from state to state RESPONSIBILITY OF ORIGINAL PURCHASER Initial User Retain original cash register sales recei
16. pt as proof of purchase for warranty work Use reasonable care in the operation and maintenance of the product as described in the Owners Manual s Deliver or ship the product to the nearest DeVilbiss Air Power Manufacturing Authorized Warranty Service Center Freight costs if any must be paid by the purchaser Aircompressors with 60 and 80 gallon tanks only will be inspected at the site of installation Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warranty Service Center the purchaser should contact DeVilbiss Air Power Company Manufacturing THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned floor models and or display models Any damaged or incomplete equipment sold is Merchandise used as rental equipment Merchandise that has become inoperative because of ordinary wear misuse freeze damage use of improper chemicals negligence accident improper and or unauthorized repair or alterations including failure to operate the product in accordance with the instructions provided in the Owners Manual s supplied with the product Air Tools O Rings and driver blades are considered ordinary wear parts therefore they are warranted for a period of 45 days from the date of purchase An air compressor that pumps air more than 50 during a one hour perio
17. well ventilated area The air compressor pump and case are designed to allow for proper cooling Clean or blow off dust or dirt that collects on the air compressor A clean air compressor runs cooler and provides longer service The ventilation openings on your air Compressor are necessary to maintain proper operating temperature Do not place rags or other containers on or near these openings Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor Low voltage can cause damage to the motor an extension cord must be used be sure it is 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the compressor in good condition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gauge number decreases 12 AWG 10 AWG and 8 AWG may also be used DO NOT USE 16 18 AWG GROUNDING INSTRUCTIONS AWARNING RISK OF ELECTRICAL SHOCKI In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances The outlet must have the same configuration as the plug Se
18. y hazardous situation which if not avoided may result in property damage Call our Toll Free Number 1 800 888 2468 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the following information Model number of your compressor e Part number and description of the item you wish to purchase Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work 22 DeVILBISS AIR POWER COMPANY MGP FA752 3A 10 11 99 qj TABLE OF CONTENTS Page SAFETY GUIDELINES CoverPage WARRANTYSTATEMENT 3 WARNING u u u u u a 4 6 GLOSSARY sier uuu s 7 DUTY CY CLE ripae AEREAS 7 DESCRIPTION OF OPERATION 7 INSTALLATIONAND BREAK IN PROCEDURES 8 Location of Air COMPIreSSOF 8 MGP FA752 3A 2 ENG Page Extension Cords 8 Grounding InstructionsS 8 r I 8 OPERATING PROCEDURES 9 STORAGE iu y amined 9 AIRCOMPRESSOR DIAGRAM AND PARTS LIST 10 TROUBLESHOOTING GUIDE 11 HOW TO ORDER REPAIR PARTS Bac
Download Pdf Manuals
Related Search
Related Contents
MODE D`EMPLOI 本社移転を機にITインフラを刷新・強化すべく 仮想化による Konami Gormiti: The Lords of Nature! Kompernass A1 User's Manual UHF アンテナ (その15)(平成27年9月3日付事務連絡)(PDF:194KB) Commission d`AMM du 19 janvier 2012 - Verbatim (20/06 資料シリーズはこちらから(PDF 24.2KB) Manual de usuario 392 PDF版取扱説明書 - 株式会社スリック Copyright © All rights reserved.
Failed to retrieve file