Home

DeLonghi PAC160 Air Conditioner User Manual

image

Contents

1. In this case it will be necessary to hole can be closed off with the flange stop e Drill a hole in a perimeter wall or in win per 13 dow pane Observe the height limits Cfig 9 and the dimensions of the hole given in N B fig 8 When operating the appliance with semi per manent installation it is advisable to leave a door slightly ajar even only 1cm to ensure free circulation of air DEHUMIDIFICATION Position the appliance in the room without inserting the air exhaust hose 14 this ensures that the dehumidified air will be released directly into the atmosphere The air emitted through the front grill will be s 0 9001 cold while the air from the rear will be warm In the window the base In the wall we fig 10 thus ensuring that the room is dehu pane of the advise you to midified without variation in temperature window insulate the sec frame tion of the wall with appropria 8 te insulation material 4 2 106 mm 160 GB 25 01 2003 10 19 Pagina 10 F Description of the control panel THE DISPLAY A B TUITI OO O l L M Q ON OFF Button Function Button Air conditioning dehumidifying ventila tion Air conditioning indicator light dehumidifying indicator light Ventilation indicator light Increase temperature button increase operating time button Decrease temperature button Decrease opera
2. PAC160intro 25 01 2003 10 23 Pagina 1 gt maintenance manual pe nae N PAC160intro 25 01 2003 10 23 Pagina 2 F Customer Thank you for purchasing an appliance made by De Longhi the interna tional leader in portable air conditioning units Thanks to our years of experi ence all around the world we are constantly improving the quality and per formance of Pinguino We are confident that you will be satisfied with your purchase and enjoy cool comfort created by the Pinguino for many years to come You should spend some time reading this instruction manual and keep it handy to refer to in order to use your Pinguino of maximum efficiency and peace of mind Cliente Cher Client Nous vous remercions d avoir choisi un produit De Longhi le plus impor tant fabricant mondial de climatiseurs portables Des ann es d exp ri ence dans le monde entier nous permettent d am liorer constamment la qualit et les performances de Pinguino Nous sommes certains que vous serez imm diatement satisfait de votre achat et que vous profiterez pendant longtemps de la fraicheur et du bien tre que Pinguino cr Nous vous prions de bien vouloir consacrer un peu de temps la lecture de ce mode d emploi et de le conserver soigneusement Ses conseils vous permettront d obtenir les meilleurs r sultats de votre Pinguino en toute s curit simaco Cliente Le agradecemos por haber elegido un producto De
3. paci60 GB 25 01 2003 10 19 Pagina 6 F Description of the appliance DESCRIPTION MODEL D Air discharge grill 2 Control Panel 3 Wheels 4 Handles 5 Housing for air exhaust hose 6 Cord winder 7 Air intake grill 8 Rating plate 9 Water collection tank 10 Water drain tube 11 Stopper for drain tube 12 Power cord Description of the Accessories 13 Stopper and flange 14 Air exhaust hose 15 Air exhaust attachment 16 Suckers 17 Wheel locks 18 Window bracket 19 Door bracket 160 GB 25 01 2003 10 19 Pagina 7 Setting up ENGLISH When positioning the appliance always ensure that nothing obstructs the intake and discharge of air AIR CONDITIONING WITHOUT PERMANENT e f you have a double window use the INSTALLATION suckers 16 supplied to keep the panes from Only a few simple steps are necessary to opening wide figure 3 obtain the comfort offered by Pinguino e Fit the air exhaust hose 14 in its housing 5 at the rear of the appliance as shown in fig 1 e Fit the window discharge attachment 15 to the end of the hose 14 e Place the air conditioning unit at a win dow or French window e Open the window a little and position the attachment 15 as shown in fig 2 160 GB 25 01 2003 10 19 Pagina 8 9 Setting up Pinguino is equ
4. We warrant each DE LONGHI AIR CONDITIONER to be free from defects in material and work manship Our obligation under this warranty is to provide one year parts and labor free from pur chase date with an additional four 4 years on any part of the sealed system consisting of the compressor evaporator condenser and factory connected refrigerant tubing This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions which accompany it and on Alternatign Current AC circuit This warranty is in lieu of all other war ranties and representations expressed or implied and all other obligations or liabilities on our part We do not authorize any other person or company to assume for us any liability in con nection with the sale or use of our AIR CONDITIONER This warranty shall not apply to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This warranty shall not apply to any AIR CONDITIONER which shall have been repaired or altered outside our factory nor shall it apply any AIR CONDITIONER which has been subjected to misuse negligence or accidents If repairs become necessary or spare parts are needed please write to De Longhi America Inc De Longhi CANADA Park 80 West Plaza One 4th floor 1040 Ronsa Court Saddle Brook NJ 07663 MISSISSAUGA ONTARIO or call Service Tel No 1 800 322 3848 LAW 3Y4 CANADA SNA AS 18
5. SHOULD YOU DO HP HIGH PRESSURE Insert and re insert the plug If the problem persists call the service centre Lt LOW TEMPERATURE If the machine is operating as an air conditioner or dehumidifier this will prevent the formation of ice The appliance will start up auto matically once the defrosting process has ended FF FAN FAILURE PF PROBE FAILURE If either of these messages appears call the service centre FE FULL TANK Empty the tank at the rear of the appliance and reposition correctly ENGLISH 160 GB 25 01 2003 10 19 Pagina 14 F Recommendations Follow these recommendations to achieve maximum efficiency from your air conditio ning unit e Close the doors and windows in the room where the unit is functioning The only exception is in the case of installation throu gh a hole in the wall In this case you are recommended to allow a small amount of air to enter through a door or window to guarantee an adequate exchange of air Do not install the heater in humid environ ments Do not use the appliance outdoors Keep the appliance a safe distance from combustible surfaces 4 ul gt 4 gt P CC close doors and windows e Protect the room from direct exposure to the sun s rays by drawing the curtains and or
6. decrease by one hour at a time but if pressed for more than 2 seconds will automatically change the time more quickly up to a maximum of 24 hours How to set the delayed start function e Connect the appliance to the mains supply and press ON OFF button next select the required operating mode temperatu re fan speed etc e Press the ON OFF button again the appliance will go into stand by mode e Press the timer button D on the display the two central seg ments will start to flash Set the number of hours after which the appliance should swit ch on by pressing the or buttons The indicator L on the display will continue to flash until the appliance starts operating The appliance can be programmed for up to 24 hours in advance How to set the delayed stop function e The appliance can be programmed for delayed stop from any of the operating modes air conditioning dehumidifying venti lation e Press the Timer button I on the display the two central seg ments will start to flash e Set the number of hours after which the appliance should swit ch off by pressing the or buttons The indicator L on the display will continue to flash until the appliance switches itself off It will then go into Stand by mode 160 GB 25 01 2003 10 19 Pagina 13 F SELF DIAGNOSIS The appliance is equipped with a self diagnosis system which identifies any operating problems IF THE DISPLAY SHOWS WHAT
7. the capacity of the air conditioner is not adequate for the conditions or the dimen sions of the room close the window eliminate source of heat set the thermostat to a lower temperature Clean the filters Strange odour in the room air filters are dirty Clean the filters Leaking condensa te from the unit appliance incorrectly installed condensate collection tank is full see instructions for correct installation of appliance Empty the tank The unit does not work for about 3 minutes after turning on the appliance The safety mechanism has been activated wait for 3 minutes See paragraph Self diagnosis if the following messages appear on the display FF LT FT PF 16 160 GB 25 01 2003 10 19 Pagina 17 F Technical specification TECHNICAL SPECIFICATION OPERATING LIMITS Power supply see rating plate Max absorbed power Room temperature 21 35 C in air conditioning 69 95 F Max absorbed power when dehumidifying Refrigerating capacity Number of fan speeds 2 silent Max air flow 460 m h Dimensions of internal unit e width 452 mm 17 80 e height 800 mm 315 e depth 455 mm 179 1 e weight 33 kg 72 8 lb Standard conditions Room temperature 35 C 95 F 40 relative humidity Outside temperature 35 C 95 F 40 relative humidity 160 GB 25 01 2003 10 19 Pagina 18 F IE CEA 00000000000000000000000022 LIMITED WARRANTY
8. Longhi lider mundi al en la fabricaci n de los acondicionadores port tiles A os de experi encia en todo el mundo nos permiten mejorar constantemente la dad y las prestaciones de Ping ino Estamos seguros que quedar inmediatamente satisfecho de su compra y que gozar por largo tiempo el fresco bienestar que da Ping ino Le pedimos que dedique un poco de su tiempo a la lectura de este man ual de instrucciones y de guardarlo con cuidado De este modo podr usar Ping ino en condiciones de maxima eficacia y serenidad C eue Cliente la ringraziamo per aver scelto un prodotto De Longhi il piu importante produttore mondiale di condizionatori portatili L esperienza di anni di lavoro in tutto il mondo ci ha permesso di migliorare la qualit e le per formaces del nostro Pinguino Siamo certi che sarete soddisfatti del Vostro acquisto e potrete beneficiare per molti anni del comfort creato dal Pin gt guino Vi consigliamo di leggere questo libretto e di tenerlo a portata di T mano in modo da ottenere i migliori risultati dal Vostro Pinguino PAC160intro 25 01 2003 10 23 Pagina 3 F e Description Description Descriptci n e Descrizione EE e ACCESSORY SET ACCESSOIRES ACCESSOIRES ACCESSORI E mm
9. e Avoid using Pinguino in oily or sulphurous atmospheres or near sources of heat Before moving the air conditioner empty water from condensation tray see draina ge instructions on page 15 Do not place hot or heavy objects on the unit Clean air filter every week see instructions on page 16 To disconnect turn control to OFF then unplug from wall socket mportant if an extension is required use heavy duty cable only minimum 14 gauge SAVE THESE INSTRUCTIONS 160 GB 25 01 2003 10 19 Pagina 5 F How does your pinguino work D the summer optimum comfort is achieved with a temperature of between 75 80 F 24 27 C and about 50 relative humidity An air conditioner removes moisture and heat from the room where it is located One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrigerant gas losing excess heat and moisture before being discharged again into the room In Pinguino a small part of this air is used to cool the refrige rant gas before hot and moist being discharged out side Each Pinguino can also be used as a fan only For more details contact DE LONGHI AMERICA INC Tel 1 800 322 3848 DE LONGHI CANADA or visit our Internet site www delonghi com ENGLISH
10. ere in summer vary between 24 27 C 75 80 F We do not advise selection of tem peratures much lower than those outside Select fan speed by pressing the FAN button Q until the fan speed indicator appears MAX P if you want the maximum power of the air conditioner to reach the desired temperature as quickly as possible MIN if you want to reduce the level of noise and still maintain a good level of comfort SILENT N when minimum noise is required AUTO M if you prefer the appliance to select the fan speed for The temperature selected on the display panel DEHUMIDIFYING FUNCTION This function is ideal for reducing humidity in the atmosphere while avoiding increases or decreases in temperature in between sea sons damp places wet spells of weather When you select the dehumidifying function the letters d will appear on the display The water is collected in the tank at the rear of the appliance When the tank is full the appliance will stop working and the display will show the letters FE Full Tank the tank must then be emptied When it is re inserted the appliance will re start auto matically N B remove the air exhaust hose 14 al a l cn In the air conditioning function the unit employs an exclusive con densation recycling system to dispose of excess moisture In normal conditions condensation is disposed of automatically When the humidity is partic
11. ipped with an adjustable win dow bracket 18 If you have a sliding window place the bracket on the window sill extend the bracket fully within the window frame and lower the window onto the bracket Insert the nozzle of the exhaust hose into the slot then connect the hose to the air conditioner Fig 4 Thanks to the wing nut it s possible to use the window bracket also for sliding windows Position the hole of the bracket to allow a correct instal lation of the exhaust hose see the following instructions If you have a sliding door use the additional set provided in order to extend the accessory to the desired length joining the two parts fig 5 adjust the total length according to your needs then fit the bracket with the rele vant nuts close the door and connect the hose fig 6 160 GB 25 01 2003 10 19 Pagina 9 e EE Setting up z Y AIR CONDITIONING WITH SEMI PERMA e Fit the flange 13 supplied to the hole 2 NENT INSTALLATION e Fix the hose 14 in the housing at the rear MN of the appliance fig 1 e Fit the end of the hose to the flange 15 as shown in fig 9 If desired Pinguino can also be installed on a semi permanent basis fig 7 MAX 45 3 MAX 115 cm MIN 19 7 MIN 50 cm 1 2 30 cm 9 7 When the hose 14 is not connected the
12. m y 1 19 17 RE Ee gt 18 CONTROL PANEL PANNEAU DE COMMANDE e TABLERO DE MANDOS PANNELLO COMANDI NE 160 GB 25 01 2003 10 19 Pagina 4 F Important Safe guards When using electrical appliances basic safety precautions should always be taken with particular reference to the following Read all instructions To protect against fire electric shock and personal injury do not immerse cable plug or appliance in water or other liquid Close supervision is necessary when any appliance is used by or near children Unplug from socket when not in use and before cleaning Do not operate if the cable plug or unit itself is damaged or faulty Return the appliance to the nearest authorised service centre for examination repair or adjust ment The use of accessories or spare parts other than those recommended by the manu facturer may result in fire electric shock or personal injury Do not use outdoors Do not use the appliance in ways other than that for which it was intended Do not place the power cable under strain Avoid twisting and or tangling Ensure that the outlet of the discharge hose is kept free from debris and blockages Do not obstruct the ventilation holes at the rear of the unit or the front grilles The Pinguino should not be installed where there may be combustible gases in the atmospher
13. partially lowering the blinds so as to maximise energy savings e Do notrest objects on the air conditioning unit e Do not obstruct the air intake or outlet e Make sure there are no heat sources in the room NU do not cover 02 gt lower the blinds or draw the curtains Make sure the unit is located on a level floor If necessary place the two blocking devices 17 under the front wheels 160 GB 25 01 2003 10 19 Pagina 15 F Cleaning Before cleaning or maintenance switch off the appliance by pressing the ON OFF button A and always unplug it from the mains supply CLEANING THE EXTERNAL UNIT We recommend cleaning the appliance with a slightly damp cloth It should then be dried For safety reasons do not wash the air condi tioner with water Precautions Never clean with benzene alcohol or sol vents Never spray with liquid insecticide or similar CLEANING THE AIR FILTERS To maintain the air conditioning unit at peak efficiency we advise you to 1 the dust filter weekly The filters are located behind the two intake gril ls The grills contain the filters To clean the filters 1 Remove the intake grills by rotating them outwards fig 11 2 Remove the dust filter by detaching it from the external grill 1 11 To remove the dust deposited on the anti bacterial filter use a vacuum cleaner If ver
14. ting time button Display Displays the temperature selected time programmed Timer button Timer operation indicator N O P Fan speed indicator Fan speed button ELECTRICAL CONNECTION Before plugging in check that the mains supply corresponds to the value shown in the specifications table the socket and the mains lead correspond to the power requirements of the appliance The socket is suited to the plug otherwise have the socket replaced The socket is properly grounded The manufactures cannot be held responsible for any dama ges due to failure in following normal safety procedures Replacement of the power cable must be carried out by qualified personnel 160 GB 25 01 2003 10 19 Pagina 11 F SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply On the display two lines will appear indicating Stand by mode Press the ON OFF button A and then the MODE button until the relevant function indicator appears viz ENGLISH Indicator 3 air conditioning Indicator D amp dehumidifying Indicator E ventilation AIR CONDITIONING FUNCTION This function is ideal in hot humid weather conditions when the atmosphere requires to be cooled and dehumidified To ensure proper function of the appliance after selecting the air conditioning function press buttons or G until the desired temperature appears on the display The temperatures most suited to the atmosph
15. ularly high an excess of condensation may built up in the TANK 19 When this happens the display will show the letters FE Full Tank indicating that the TANK should be emptied Whe never conditions of high humidity make the problem recurrent you may discharge the excess water directly into a drain using the rub ber tube supplied The tube should be inserted into the hole provi ded after having removed the rubber stopper see figure Make sure the TANK is put back correctly otherwise the display will continue to show the letters FE ec 160 GB 25 01 2003 10 19 Pagina 12 F Once the dehumidifying function has been selected the fan speed cannot be changed The appliance will automatically select the correct fan mode Silent speed VENTILATION Adjust the fan speed by pressing the FAN Q button as illustra ted in the air conditioning function Min Bear in mind that the higher the speed the greater the volume of speed air filtered by selecting the Silent speed less air is filtered but the noise level is low AUTO function cannot be selected in this mode The display will show the fan speed selected PROGRAMMING THE TIMER The timer programs the appliance to switch on and switch off This will save electrical energy by optimizing the operating times The timer is set using the buttons F or G these increase and
16. y dirty immerse in warm water not more than 104 F and rinse thoroughly Allow the filter to dry To replace fit the filters to the intake grill and attach to the applian ce Dust filter intake grille BEGIN OF SEASON CHECKS Check that the power cord and plug are undamaged and that the appliance is pro perly earthed The installation instructions should be observed meticulously END OF SEASON OPERATIONS Empty the water from the tank Remove the tank 9 and empty it To drain any residual water from the internal circuit remove the stopper 11 from the drain tube 10 and drain completely Re insert the stop per and re position the tank correctly 9 Clean the anti bacteria filters and dry well before replacing ENGLISH 160 GB 25 01 2003 10 19 Pagina 16 T Troubleshooting PROBLEM CAUSES REMEDY The air conditioner the power is off does not work the appliance is not plugged in Plug it in The air conditioner works only for a short time The exhaust hose is twisted The exhaust hose is blocked The exhaust hose is bent Position exhaust hose correctly Check for obstacles blocking the exhaust system Straighten the hose The air conditioner works but does not cool the room a window is open there is a source of heat in the room lamp burner etc or there are many people in the room the thermostat is set too high air filters are dirty