Home

DeLonghi KW 85 Air Conditioner User Manual

image

Contents

1. The cooling system will shut down when room temperature drops below the set temperature The fan will however conti nue to operate at the set speed If the room temperature rises above the temperature set the cooling system comes on again automatically Installation CHOOSING THE INSTALLATION SITE Position the air conditioning unit on a flat sur face where the air outlet grilles cannot be obstructed Position the appliance at least 50 cm 19 7 away from walls or obstacles CABLE WINDER Before installing the air exhaust hose mount the two cable winder brackets using the screws supplied as shown in the figure AIR EXHAUST ACCESSORIES S INSTALLING THE AIR EXHAUST HOSE LE Open out the end of the hose and screw the two adapters on counterclockwise see figu re Fit the square adapter on the air exhaust hose to the air exhaust outlet on the appliance Connect the other end flange to the neare st window Important the air exhaust hose must be between 500 mm 19 7 and 2000 mm 78 7 long You are recommended to keep the air exhaust hose as short as possible During installation keep the hose as horizontal as possible without distorting it Do not con nect the terminal to other exhaust ducts flue or chimney as this could lead to malfunction Correct wall installation the hole must be at a height of between 40 cm 15 7 and 130 cm
2. 51 18 from the floor GB KW85 18 11 2003 14 02 Pagina 10 4 Installation Ifthe flange hose must be curved to expel the air you should follow the measurements given in the figure 50 cm 19 7 in 50 cm 19 7 in O O Incorrect installation diagram the bend in the hose is excessive and could easily lead to malfunction Es MOUNTING THE ADJUSTABLE WINDOW CLOSU RE CROSSPIECE only on some models The appliance is provided with an adjustable bracket If you have a sliding window position the cros spiece in the window frame extend it comple tely then close the window onto the crosspie ce Fit the window flange onto the end of the air exhaust hose position it on the hole in the crosspiece then fit the other end of the hose onto the back of the air conditioning unit This considerably reduces heat dispersion due to contact between the room and the outside environment The crosspiece is 40 mm 1 55 wide and between 675 mm 26 7 and 1230 mm 48 4 long GB KW85 18 11 2003 14 02 Pagina 11 4 Installation CONDENSATI
3. connect to multiple sockets e Once plugged into the outlet wait about two seconds until you hear a beep then press the O button to turn the applian ce on OPERATING IN AIR CONDITIONING MODE 1 Make sure the condensation tank is cor rectly in place 2 Press the MODE button repeatedly until the air conditioning mode is selected COOL appears on the display While the unit is operating in air conditio ning mode always place the exhaust hose through an open window to eject the hot air from the room 3 Press the SET TEMP button to set a suita ble room temperature between 17 C 62 F and 31 C 87 F 4 Press the FAN SPEED button to select a suitable fan speed Max Med Min OPERATING IN DEHUMIDIFYING MODE 1 Keep the windows and door closed to make dehumidification of the room more efficient 2 Make sure the condensation tank is cor rectly in place 3 Repeatedly press the MODE button to select the dehumidifying mode DRY appears on the display 4 Neither the fan speed nor temperature can be regulated 5 Do not use the exhaust hose to expel the air outside The hot air given out at the back of the appliance should not be expelled from the room GB KW85 18 11 2003 14 02 Pagina 8 f Operation TIMER FUNCTION When the air conditioning unit is off out plug ged into the outlet to turn it on at the required time press the TIMER ON OFF button O on will appear on t
4. IONER with an additional four 4 years free on any part of the sealed system consisting of the compressor evaporator condenser and factory connected refrigerant tubing Labor and all other parts during the additional four 4 year warranty are to be paid by the owner All AIR CONDITIONERS in need of repair are to be shipped to an authorized De Longhi service center at the owner s expense and De Longhi will then incur the return ship ping costs After the first five 5 years of ownership all expenses all parts labor and shipping are to be paid by the owner of the unit This warranty shall apply only if the AlR CONDITIONER is used in accordance with the factory directions that accompany it and on an Alternating Current AC circuit This warranty is in lieu of all other warranties and representations expressed or implied and all other obligations or liabilities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This war ranty shall not apply to any AIR CONDITIONER that has been repaired or altered outside our fac tory nor shall it apply to any AIR CONDITIONER that has been subjected to misuse negligence or accidents If repairs become necessary see contact information below U S Residents Please contact our toll free hotline at 1 800 322 3848 or log onto our website at www delonghi com For all accessories spare parts or replacement pa
5. ON DRAINAGE When the air conditioning unit is operating in air conditioning or dehumidifying mode the condensation is collected in a special tank When the tank is full the tank full indicator light on the control panel flashes Remove the condensation tank empty and replace on the unit as shown in the following figures Attention 1 While the air conditioning unit is operating in air conditioning or dehumidifying mode do not extract the condensation tank before it is full otherwise a buzzer will sound indica ting that the compressor has stopped The unit will switch to FAN mode 2 To remove the tank before it is completely full the unit must be stopped by turning it off or operating it in FAN mode only waiting about three minutes to avoid the conden sation dripping outside the tank then remo ving the tank 3 Do not remove the cap of the tube in the water tank compartment present in certain models only while the unit is operating with condensation collecting in the tank as this could lead to leaks of water CONTINUOUS CONDENSATION DRAINAGE To drain condensation continuously without the air conditioning unit shutting down pro ceed as follows models designed for conti nuous condensation drainage only 1 Pass the tube in the tank compartment through the hole in the tank see figure 2 Remove the cap from the tube and con nect it to an external pipe not provided able to drain t
6. Sales Inquiries 800 934 9194 KENWOOD GB KW85 18 11 2003 14 02 Pagina 2 Important safeguards Use this appliance only as described in this instruction manual As with any electrical appliance the instructions aim to cover as many eventualities as possi ble Caution and common sense should be used when operating and installing this air condi tioner This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes It is dangerous to alter or modify the unit s characteristics in any way The appliance must be installed in line with the relevant national legislation Should repairs be necessary contact the nearest authorized De Longhi Repair Service Center Unauthorized De longhi servicing can be dangerous This appliance is to be used by adults only keep away from children In the case that the power cord becomes damaged this must be replaced only by specialized per sonnel authorized by the manufacturer Always ensure the appliance is grounded If you have any doubts check with a qualified elec trician Avoid using extension cords with the unit Before cleaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Do not rest hot or heavy obje
7. cts on the appliance Clean the filters at least once a week Avoid using heaters near the unit The unit should be transported in a vertical position If this is not possible secure the unit at an angle do not lie it horizontally Before transporting the unit drain the condensation collecting tray and tank After transporta tion wait at least 1 hour before switching on the unit The packaging materials can be recycled You are therefore recommended to place them in the special containers for differentiated waste collection SAVE THESE INSTRUCTIONS GB KW85 18 11 2003 14 02 Pagina 3 f Introduction The portable air conditioner is a compact unit for regulating air temperature and humidity Its extremely flexible characteristics make it easy to use at any time and in any room It can be operated in multiple modes including cooling dehumidifying and ventilating The appliance has been designed for dome stic use and may be used in the home office etc It must be connected to an outlet with an impedance of less than 0 197 Ohms If necessary consult your electricity supply company for information on impedance values TIPS FOR ENERGY SAVING e Keep blinds and or curtains and windows closed during the sunniest hours of the day cooling func tion e Keep the filter clean In normal conditions the filter should be cleaned about every 2 weeks The fil ter eliminates part of the pollutant particles or dust transported in the air Air
8. eck it no longer occurs e Plug into the outlet e Check the outlet switch or turn the air conditioning unit switch on e Empty the water in the tank e Position the condensation tank correctly e Clean and free from obstructions e move the heat source e clean the air filter e set the temperature e set the fan speed correc tly There is excessive noise and vibration The unit shuts down or starts up frequently e It is caused by the refrige rant fluid running through the tubes e Is it sloping e Is the air expelled through the exhaust hose correctly or does the hose follow a correct path e Other exhausts have been connected together on the same hose e This is normal e Place the appliance in a horizontal position e Try and keep the air exhaust hose in as horizon tal a position as possible to facilitate evacuation of the air e Do not use other exhaust hoses always use the hose supplied to expel the air GB KW85 18 11 2003 14 02 Pagina 14 Limited Warranty De Longhi is the distributor of Kenwood home appliances This warranty applies to all home appliances with De Longhi or Kenwood brand names FOR CONTIGUOUS UNITED STATES ONLY Limited Warranty We warrant each De Longhi AIR CONDITIONER to be free from defects in material and workman ship From the purchase date our obligation under this warranty is to provide one 1 year free parts and labor on the entire AIR CONDIT
9. grille END OF SEASON PROCEDURE L Filter holder grille Turn the appliance off and disconnect from the outlet by unplugging from the outlet In models with a continuous condensation drain tube only before emptying the con densation from the tank remove the cap from the plastic tube to enable water in the tube to flow into the tank then operate the unit in fan mode for half a day to ensure that the inside of the unit is completely dry Empty the condensation water from the tank clean and dry Wind the power cable around the cable winder then cover the appliance with a cover or bag and store in a dry place plastic tube cge cap GB KW85 18 11 2003 14 02 Pagina 13 4 Troubleshooting Before contacting an authorized technical service center check the following Problem Check Solution The appliance does not work The appliance does not cool satisfactorily e f there is a power outage e If the plug is not correctly inserted in the outlet e If the outlet switch or the switch on the air conditio ning unit is off e f the condensation tank indicator light is on e f the condensation tank is positioned correctly e f the air intake and outlet grilles are blocked e f there are other sources of heat in the room e f the air filter is very dirty e f the temperature set SET TEMP is not correct e If the internal fan speed is on slow e Ch
10. he condensation continuou sly Condensation inage tube GB KW85 18 11 2003 14 02 Pagina 12 4 Maintenance MAINTENANCE Turn the appliance off and unplug from the outlet before cleaning Make sure the unit is disconnected from all voltage before proceeding with mainte nance This avoids the risk of electric shock Never use chemical solvents such as ben zene and alcohol to clean the surface of the unit This could scratch or damage the surface or even distort the external part Use water with delicate detergents or a soft cloth only to clean or dry plastic parts To clean the condensation tank remove and completely empty it of water Clean with neutral detergents rinse and dry tho roughly Then replace in the original position AIR FILTER If the air filter is blocked by dirt or dust the flow of air diminishes reducing the perfor mance of the appliance and leading to mal function The air filter must be cleaned and or washed at least once every two weeks Ts 2 3 5 Open the air filter holder grill by pulling it towards the outside Remove the filter from the filter holder gril le Wash the air filter by immersing it delicately in warm water no more than 40 C 104 F with neutral detergent rinse and dry completely in the shade Replace the dry filter in the grill fastening it with the pins on the inside surface of the grille Replace the grille on the unit
11. he display then press the TIMER HOUR button until the number of hours to elapse before the appliance comes on appears on the display Vice versa when the air conditioning unit is on to turn it off at the required time press the TIMER ON OFF button e or will appear on the display then press the TIMER HOUR button until the number of hours to elapse before the appliance goes off appears on the display The timer can be set from one to 12 hours AUTOMATIC SWING FUNCTION Press the SWING button once The fins will swing distributing the air flow in the room Press the button again the flow will be steady in one direction CHILD SAFETY Pressing the and buttons on the control panel together for more than two seconds locks the keypad The symbol appears on the LCD display The same keypad lock function can be acti vated on the remote control unit by pressing the G button To unlock repeat the operation BEFORE USING THE APPLIANCE 1 If the appliance has been in a horizontal position during storage or transport you are recommended to wait at least three hours before turning it on 2 Always position the air conditioning unit on a stable surface 3 Attach the air exhaust hose to the air con ditioning unit 4 Plug the air conditioning unit into a suitably rated outlet 5 Set the various functions of the air condi tioning unit according to your require ments 6
12. ntilating FAN FAN SPEED MODE gt qa SWING button Press this button to distribute O SWING the air flow evenly throu Ss ghout the room swing or in a specific direction fixed position Operation SETTING THE REMOTE CONTROL CLOCK Remove the cover of the battery compartment on the back of the remote control unit After inserting two 1 5 V alkaline batteries in the compartment the clock is automatically set at 12 00 If you want to set the time to 10 30 proceed as follows Press the CLK button in the battery compart ment with a pointed object such as a pencil The time indicator on the display flashes and the correct time can be set Press the HOUR button on the remote control unit to set the hours set to 10 am Press the MIN button on the remote control unit to set the minutes set to 30 Press the CLK button again to confirm the opera tion then replace the battery compartment cover OPERATING RANGE The operating range of the air conditioning unit goes from a minimum of 17 C 62 F to a maximum of 35 C 95 F with a choice of temperatures in cooling mode of from 17 C 62 F to 31 C 87 F In dehumidifying mode the operating range goes from 20 C 68 F to 31 C 87 F The temperature cannot be selected in advance POWER SUPPLY e Plug the air conditioning unit into a suita ble outlet Do not
13. quality thus depends on the frequency with which the filter is cleaned Control panel All functions of the unit can be controlled from the control panel or the remote control unit certain models only gt gt De GB KW85 18 11 2003 14 02 Pagina 6 4 Description MA SET TEMP buttons Use these buttons to set the required room tempe rature between 17 C 62 F and 31 C 87 F The temperature set is increased or reduced by 1 C 33 F HEAT 68 COOLDRY FAN S us S a m SON 8 00 FAN SPEED button Press this button to set the speed of the air flow Max Med Min Button Press this button to activate the timer function turns the appliance off if already on and vice versa HOUR and MIN buttons Press these buttons to set the hour and minutes on the remote control unit or using the HOUR button only to set the time the air conditioning unit will come on and go off using the TIMER function 5 Button Press this button to lock or unlock the keypad on the control panel Display NT ON OFF button Press this button to turn the air conditioning unit on or off SET TEMP O MODE key Press this button to select the various operating modes air conditioning A 5N COOL dehumidifying Ca DRY or ve
14. rts please contact our parts division at 1 800 865 6330 CANADA Residents Please contact our toll free hotline at 1 888 335 6644 or log onto our website at www delonghi com Other couniries Please visit www delonghi com

Download Pdf Manuals

image

Related Search

Related Contents

Guía Rápida Teléfonos Advanced Reflexes v1.0  Bedienungsanleitung - Spiel & Flugbox AG  Samsung DA68-01812G User's Manual  Peerless PRGS-ALU0811 mounting kit  Powermate PM0106001 Parts list  BIOSTAT® B - Sartorius AG  Uniden EXAI918 Owner's Manual  Star Micronics XB-2420 User's Manual  Mode d`emploi Statik-Disc  