1. Separate the green and white oven cable wires Connect the white oven cable wire to the neutral white wire in junction box Connect the green grounding oven cable wire to the green grounding wire in the junction box Do not connect the green grounding wire to the neutral white wire in junction box 1Ne Ranlara tha ininctinn hav cavar 6 SECURE THE OVEN TO THE CABINETRY AND REFIT THE DOOR S A Ensure supplied spacer Fake care not to damage thetower trim of the oven is fitted between oven and cabinetry B Sliding frame push fully into place 7 FINAL CHECKLIST oga 04 a ae Make sure the appliance is level and securely fitted to the cabinetry and both oven doors open and close freely Make sure all the internal packaging has been removed from the oven cavity Make sure all oven vents and openings are clear and are free of any obstruction damage Important Failure to make sure all oven vents are unobstructed may result in poor product performance Turn the power to the oven on The clock should light up and flash 12 00pm Set the clock to the current time Turn the oven function knob to Bake and the oven temperature knob to 350 F Air should blow out of the vent at the bottom of the oven Inside the oven cavity all three oven lights should come on After five minutes open the oven door and the air inside should
2. 693 K minimum inside depth of cavity 22 52 575 Note If installing a cooktop above the oven ensure adequate clearance is provided for the cooktop as per the cooktop manufacturer s instructions G PRODUCT AND CABINETRY DIMENSIONS Double oven models N 2 5 mm 8 1346 16 20 mm Ensure the cavity is completely sealed with no gaps Product and cabinetry dimensions inches mm 3 5 a9 m A overall height of product 48 e 1230 B overall width of product 29 34 757 C overall depth of product without handle 23 1546 608 D height of chassis 47 eo 1217 E width of chassis 28 14 718 F depth of chassis 22 7 6 570 G depth of oven frame and control panel excl knobs 1 38 H depth of oven doors open measured from front of oven frame 20 7 530 minimum inside width of cavity 28 V2 724 overall width of cabinetry 30 762 J inside height of cavity 48 Va 1222 J overall height of cabinetry 48 54 1235 K minimum inside depth of cavity 22 3 575 UNPACK THE OVEN AND REMOVE THE DOOR S Double models featured for illustration purposes only A G ELECTRICAL CONNECTION TO JUNCTION BOX n Junction box location for undercounter installation Junction box location for wall inst
3. Installation instructions Wall oven WOU 130 and WOUD 230 models _ a_ by Fisher amp Paykel Important SAVE THESE INSTRUCTIONS The models shown in this document may not be available in all markets and are subject to change at any time For current details about model and specification availability in your country please go to our website www dcsappliances com or contact your local DCS Customer Care Representative CT SAFETY AND WARNINGS A WARNING Very Heavy A WARNING Electrical hazard Always disconnect the oven from the mains electricity supply before carrying out any maintenance operations or repairs Do not attempt to lift this product unassisted Lifting unassisted may cause serious injury Failure to do so may result in electrical shock or death SINGLE OVEN MODELS A WARNING Cut hazard Take care panel edges are sharp Failure to use caution could result in injury or cuts Impor tant safe ety pr ecautions Save these instructions for the local inspectors use To avoid hazard follow these instructions carefully before installing or using this product Please make this information available to the person installing the product as it could reduce your installation costs This oven is to be installed and connected to the electricity supply only by an authorized person Ifthe installation requires alterations to the domestic electrical system call a qualified electricia
4. allation e AN WOU 130 Max current draw 19 4 A Max load 4 6 kw Nameplate WOUD 230 Max current draw 38 3 A Max load 9 2 kW white and green grounding oven wires factory taped cable from power supply green gro oven wires factory taped conduit connector cable from power supply UL listed conduit connector Disconnect the power supply Remove the junction box cover Connect the oven cable to the junction box through the U L listed conduit connector Connect the two black wires together with twist on connectors Connect the two red wires together with twist on connectors Connect electrical connection according to local codes and ordinances If local codes permit connecting the cabinet grounding conductor to the neutral white wire in the junction box 7a Connect the factory taped green and white oven cable wires to the neutral white wire in the junction box 8a Replace the junction box cover OR If local codes DO NOT PERMIT connecting the cabinet grounding conductor to the neutral white wire in junction box 7b Separate the factory taped green and white oven cable wires 8b Connect the white oven cable wire to the neutral white wire in junction box 9b Connect the green grounding oven cable wire to a grounded wire in the junction box 10bReplace the iunction box cover 7c 8c 9c OR If connecting to a four wire electrical system
5. feel warm and the top element should be glowing red Turn both the oven function knob and oven temperature knob back to OFF and repeat for the other oven if the appliance is a double model TROUBLESHOOTING OOOOOO If the appliance is not functioning correctly after installation check the following Check that the circuit breaker has not tripped or the fuse blown Make sure that the electrical connections have been correctly made Make sure that power is being supplied to the oven Make sure the voltage is correct across all phases If a problem occurs consult the Troubleshooting section of the User Guide If after checking these points you still need assistance please contact us through a DCS Customer Care Representative by phone 1 888 281 5695 email support dcsappliances com or www dcsappliances com 599558A USCA 06 08
6. fied electrician determine that the grounding path and wire gauge are in accordance with local codes Do not use an extension cord with this appliance When you install the oven Do not seal the oven into the cabinetry with silicone or glue This makes future servicing difficult Fisher amp Paykel will not cover the costs of removing the oven or of damage caused by this removal Use the supplied screws to secure the oven to the cabinetry Do not over tighten the screws Do not stand on the door or place heavy objects on it Do not lift the oven by the door handle Take extra care not to damage the lower trim of the oven PRODUCT AND CABINETRY DIMENSIONS Single oven models Installation diagrams for illustration purposes only Ensure the cavity is completely sealed with no gaps Product and cabinetry dimensions inches mm 3 z gt T w ao A overall height of product 27 Ye 688 B overall width of product 29 34 757 C overall depth of product without handle 23 6 608 D height of chassis 26 34 675 E width of chassis 28 4 718 F depth of chassis 22 7 6 570 G depth of oven frame and control panel excl knobs 1 2 38 H depth of oven door open measured from front of oven frame 20 7 530 l minimum inside width of cavity 28 Ya 724 l overall width of cabinetry 30 762 J inside height of cavity 26 6 681 J overall height of cabinetry 27 46
7. n The electrician should also check that the socket cable section is suitable for the electricity drawn by the oven The oven must be grounded To connect the oven to the mains do not use adapters reducers or branching devices as they can cause overheating and burning Installation must comply with your local building and electricity regulations Failure to install the oven correctly could invalidate any warranty or liability claims Before you install the oven please make sure that The oven will rest on a surface that can support its weight The countertop and oven cavity are square and level and are the required dimensions The height from the floor suits the user The oven door can open fully without obstruction Electrical requirements Connect oven with copper wire only Do not cut the conduit A ULL listed conduit connector must be provided at the junction box Do not ground to a gas pipe Do not have a fuse in the grounding or neutral circuit Fuse both sides of the line A time delay fuse or circuit breaker is recommended If using a time delay fuse then fuse both sides of the line Flexible armored cable from the appliance should be connected directly to the junction box Connect directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable with grounding wire If codes permit and a separate grounding wire is used it is recommended that a quali