Home

Dacor DHI361 Ventilation Hood User Manual

image

Contents

1. 61 cm of straight duct between them e Avoid S or back to back configurations of adjacent elbows e In regions where the weather gets extremely cold thermal breaks such as a short section of non metallic duct should be used to avoid indoor heat loss The break should be located as close to the pass through point to the outside as possible Do not use flexible metal duct e Do not use duct work that is smaller in cross sectional area than the recommended size duct 8 round INSIPNIPNIO N IE INOREN ASSEMBLE THE Hoop Do not install the range hood unless the electrical service provided meets the range hood specifications Observe all governing codes and ordinances during planning and installation Contact your local building department for further information A qualified technician must complete the installation of this built in appliance The owner is responsible to make sure the hood is properly installed To avoid an electric shock hazard and property damage locate electric wires and water pipes and avoid drilling in the vicinity The range hood is heavy To prevent personal injury and property damage install the hood only as specified below Make sure all screws used to mount and assemble the hood are tight ELECTRIC SERVICE INSTALLATION The electrical connection box must be Connected to a 120 Vac 60 Hz dedicated grounded circuit protected by a 15 Amp circuit breaker or time
2. f P your Dacor dealer or the Dacor Customer Service Team e INSTALLER In the interest of safety and to minimize problems read these installation instructions completely and carefully before you begin the Phone 800 793 0093 installation process Leave these installation instructions with the customer e CUSTOMER Keep these installation instructions for future reference and the local electrical inspector s use Dacor Customer Service Team Web site www Dacor com All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved MPORTANT SAFETY INSTRUCTIONS Important Information About Safety Safety Symbols and Labels Instructions DANGER The Important Safety Instructions and warnings in these Immediate hazards which WILL result in severe instructions are not meant to cover all possible problems personal injury or death and conditions that can occur Use common sense and caution when installing maintaining or operating this or any WARNING other appliance Hazards or unsafe practices which COULD result in Always contact the Dacor Customer Service Team about severe personal injury or death roblems and conditions that you do not understand i CAUTION Hazards or unsafe practices which COULD result in minor personal injury or property damage DANGER IMPORTANT If you smell gas e Do not use or light any app
3. delay fuse Located a minimum of 17 43 2 cm above the bottom of the range hood MOUNTING BRACKET INSTALLATION 1 4 Locate the mounting bracket and position it against the ceiling at the previously determined mounting location see page 5 Using a pencil mark the four mounting hole locations on the ceiling Drill four 1 16 1 6 mm pilot holes at the mounting hole locations Attach the bracket using four 12 screws not supplied Make sure the screws penetrate into the wood mounting surfaces 1 1 2 3 8 cm WARNING Lifting and hanging the range hood requires two people Do not attempt to lift the hood without assistance 4 Place the hood assembly on a soft surface with the bottom side down during assembly to avoid damage Tip the hood up on it s side and remove the filter s to reduce weight and avoid damage Inside the exhaust outlet s there are metal or plastic damper flaps The flaps close to help prevent back drafts when the blower is turned off Make sure all the flaps open and close freely before proceeding Remove any shipping tape that may be present Remove the tape that holds the wiring in place on top of the hood during shipment On models with two blowers Put the exhaust cowling over the blower outlets on the top of the hood Fasten the cowling in place with 14 machine screws gacor 7 INSIENIENIO N IE INI U II NIS Hoop AssEMBLY CONT 6 Separat
4. National Fire Protection Association 1 Batterymarch Park Quincy Massachusetts 02269 9101 gacor 5 KENIA INNIN PLAN THE Duct WORK INSTALLATION WARNING e To reduce the risk of fire and to properly exhaust air be sure to duct air outside the house or building Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages e Tape all duct joints securely to prevent combustion by products smoke or odors from entering the home Doing so will also improve system efficiency e Do not exhaust more than one vent into a single duct e Use only duct work constructed of materials deemed acceptable by state municipal and local codes e Range hoods may interrupt the proper flow of smoke and combustion gases from furnaces gas water heaters and fireplaces To avoid drawing lethal gases into the home follow the manufactures recommendation for these devices and consult NFPA and ASHRAE recommendations e DO NOT install an additional in line or external blower to increase the length of the duct run Even small differences between blower air flow rates can greatly reduce the air draw by the hood All duct work materials including screws and duct tape must be purchased separately by the customer When planning new duct work always look for the shortest most direct route to the outside The hood exhaust connects to an 8 inch round duct You can increase the duct size over the duct run i
5. described below e Install the duct work system Lift the chimney up 1 Before raising the hood into position lift it up and orient and reach inside the framework to access the hood it so that the control panel faces the same direction as exhaust Attach the duct to the hood exhaust with duct the front of the cooktop or range tape alone Use sheet metal screws not provided and 2 Lift the hood assembly up on both sides and slip the duct tape on all the remaining duct system joints end of the framework over the mounting bracket Push up until all four mounting springs protrude out of the DUCT WORK mounting slots on the top of the framework THROUGH CEILING l CONNECTS TO 3 Attach the framework to the mounting bracket using EXHAUST OUTLET four self tapping screws INSIDE FRAMEWORK MOUNTING SPRINGS 10 dacor INGUENIENIO NIB INSTIIUGNI NS FINAL ELECTRICAL INSTALLATION FINAL CHIMNEY ASSEMBLY IMPORTANT Be careful not to pinch the electrical wires WARNINGS while assembling the chimney e To avoid electrical shock or fire hazard make sure the power supply at the fuse or junction box is turned off before proceeding with final electrical installation 1 Move the chimney up toward the ceiling Line up the holes on the side of the chimney above the vents with the holes on the side of the mounting bracket e Improper connection of the hood electrical wiring may create an electric shock or fire hazard
6. removed if service is required e Plan the installation so that all minimum dimensions are met or exceeded see page 3 Dimensions shown provide minimum clearances unless otherwise noted Preparing the Mounting Bracket Location The mounting bracket must be attached directly to the studs in the ceiling or to a reinforced mounting block secured to the studs See below for mounting bracket hole dimensions 12 9 16 amp 15 6 cm e Attach the mounting bracket directly above the center of the cooktop e Attach the mounting bracket to the mounting surfaces with 12 screws not supplied The screws must be of sufficient length to penetrate into the wood mounting surfaces at least 1 1 2 3 8 cm e The mounting surface must be level e Allow clearance in the center of the mounting bracket for the exhaust duct to pass through the ceiling 8 inches in diameter ELECTRICAL PowER SUPPLY Electrical Specifications It is the owner s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician The electrical installation including minimum supply wire size and grounding must be in accordance with the National Electric code ANSI NFPA or latest revision and local codes and ordinances Connect the hood to a 120 Vac 60 Hz dedicated grounded circuit protected by a 15 Amp circuit breaker or time delay fuse A copy of this standard may be obtained from
7. OT USE WATER including wet dish cloths or towels a violent steam explosion may result Use a fire extinguisher ONLY if e You have a Class ABC extinguisher and you already know how to operate it e The fire is small and contained in the area where it started e The fire department is being called e You can fight the fire with your back to an exit ODTENEK GENERAL SPECIFICATIONS DIMENSIONS Tolerances 1 16 0 1 6 mm 0 ALL MODELS unless otherwise stated 600 CFM 1200 for units with 2 Eem 12 SHG 313m Blower i blowers with electronic speed control Lights 12 Vac 20 W halogen Baffle type dishwasher safe 430 stainless steel 120 Vac 60 Hz see below for current Voltage rating Circuit 120 Vac 15 Amp grounded dedicated Requirement circuit minimum MODEL SPECIFIC f Maximum 3 75 A ba 121 9 cm 54 137 2 cm E 1S i P O lt Ke mM een Q gt E S Ti N 00 N 25 5 8 65 1 cm DHG DHI421 eee DHi482 DHI542 2 6 2 710A 18 1 4 on models DHI482 DHI542 and DHI602 DHI602 2 6 3 710A 30 on models DHI482 DHI542 and DHI602 IMPORTANT The minimum installed distance from the hood to the cooktop surface must be no less than 30 inches The minimum specified distance may be higher for the particular range or cooktop in use Check the manufacturers specifications for the cooktop o
8. and may result in damage to the hoods electrical system Do not ground the hood to the neutral white power supply wire Connect the hood ground wire to a separate properly grounded wire installed by a licensed electrician Connect the house power supply wires to the wires coming out of the hood junction box inside the chimney 1 Connect the white wire from the hood to the neutral white power supply wire 2 Connect the black wire from the hood to the hot black power supply wire 3 Connect the green and yellow wire from the hood to the house ground green wire from the junction box 2 Attach the sides of the chimney to the bracket using two machine screws one on each side YELLOW GREEN 3 Carefully slide the bottom portion of the chimney down TO GREEN until it rests on the top of the range hood Reinstall the range hood filter s before operation gacor 11 INSIENIPENIO N IE INI IU NI NIS VERIFYING PROPER OPERATION Turn on power at the junction or fuse box If the control panel is not lit remove the filter s and turn on the main power switch located behind the filters on the underside of the hood Replace the filter s Touch the light key Verify that all the lights come on Touch the light key again to turn the lights off Touch the blower key once and release Verify that one light is showing on the blower speed indicator and that the blower is on at low speed Touch
9. and release the blower repeatedly three times Verify that with each touch of the key the number of lights on the blower speed indicator increases and that the blower speed increases Touch and hold the blower key until the blower turns off If the hood fails to operate properly Verify that power is supplied to the hood Check the electrical connections to ensure that the installation has been completed correctly Repeat the above test If the appliance still does not work contact an authorized Dacor service company at 800 793 0093 Do not attempt to repair the appliance yourself Dacor is not responsible for service required to correct a faulty installation 12 dacor INSTALLATION CHECKLIST WARNING To ensure a safe and proper installation the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked Proper installation is the responsibility of the homeowner The importance of proper installation of your Dacor range hood cannot be overemphasized Is the mounting bracket properly attached to the ceiling according to the instructions on page 7 Is the hood properly secured to the mounting bracket with the machine screws see page 10 Is the duct work completely installed Are all joints attached with sheet metal screws and wrapped with duct tape see pages 6 and 10 Is the range ho
10. e the bottom framework piece from the top 9 Attach the hood junction box to the rim of the bottom FRAMEWORK framework piece The top frame work piece has 5 inch framework piece using two machine screws as shown slots on the the sides The bottom piece has a series of holes on the sides Position the bottom framework piece on top of the hood Slide the studs on the top of the hood into the holes on the bottom of the framework piece The cut outs for the wiring allow the bottom framework piece HOOD to fit on only one way If it does not fit properly turn it JUNCTION 180 so that the cut outs line up Make sure all wiring is BOX tucked inside the framework piece and are not pinched 4 8 8 Eo z y 10 Attach the external motor terminal block to the rim of the bottom framework piece using two machine screws as shown It mounts on the opposite side of the hood junction box BOTTOM s 8 ee E E 0 ee a AA EXTERNAL MOTOR TERMINAL BLOCK 8 Use eight provided lock washers and nuts to secure the bottom framework piece to the top of the hood Cacor INSIPNIPNIIO N IE INST U NI NIS 11 Determine the required framework height To deter CHIMNEY mine the required framework height e Measure the distance from the ceiling to the cooktop Subtract the height at which the hood will be mounted 30 minimum and the hood thickness 12 1 2 f
11. f desired To prevent a back draft never decrease the duct size over the run Do not rely on duct tape alone to seal duct joints Fasten all connections with sheet metal screws and tape all joints with duct tape Use sheet metal screws as require to support the duct weight e To prevent back drafts a damper at the duct outlet may also be required Make sure duct work does not interfere with floor joists or wall studs 6 gacor Calculating the Maximum Duct Run Length The maximum straight duct length for the hood is 100 feet For each elbow and transition added to the duct work a certain number of feet must be subtracted from the maximum straight length to compensate for wind resistance To determine the length the duct work cannot exceed subtract all of the equivalent lengths of the elbows and transitions listed below from 100 feet Duct Work Equivalent Lengths DUCT PIECE SUBTRACT 45 elbow 8 Dia 3 1 4 x 10 to 8 round Wall cap with damper 30 feet 30 feet Duct Work Design Tips e Wherever possible reduce the number of transitions and turns to as few sharp angles as possible Two staggered 45 angles are better than one 90 e Keep turns as far away from the hood exhaust as possible with as much space between each bend as possible For best performance use round duct instead of rectangular especially when elbows are required e If multiple elbows are used try to keep a minimum of 24
12. gacor The Life of the Kitchen INSTALLATION INSTRUCTIONS M LLENNIA IsLANb CEILING Mount Rance Hoops For use with models DHI361 DHI421 DHI482 DHI542 DHI602 Part No 101744 Rev B INIRA CONNIEK Important Safety INStruUCtions ccsseeeesetteeeeeeeeeeeeees 1 Installation INStrUCtiONS cccccceseeesteeeeeeeteneeeeeeeeee 7 12 Product Specifications c cc ecccseseeeeeesesseeeeeeseseeeees 3 Electric Service Installation cccccccecsseeeeeeeesteeeeeees 7 General Specifications sieurs an 3 Mounting Bracket Installation cccceeeeeeeeteeeeeneeees 7 DIMENSIONS aneirin ene ei eee ieri erai 3 Assemble the Hdd 7 Preparing for Installation cccsssseeeeeeeseeeeeeeees 4 6 Hanging the Range Hood cccceeeeeeeeeeeeeeeneeteees 10 Verify the Package Contents 4 Install the Duct Work eccinteninisde cecil naeenivalans is 10 Planning the Locations S 5 Final Electrical Installation cccccceccseeeeeeeeeeeeeereees 11 Electrical Power Supply cccccccccccccseeecsseeesseesessseeeeseeens 5 Final Chimney Assembly ce cece scene 11 Plan the Duct Work Installation cccccccceeeesteeeeeteeees 6 Verifying Proper Operation 0 ec eee eects 12 Installation Checklist cceccecceeecceeceeeeeeeeeeeeeeneneeees 12 BEFORE YOU BEGIN IMPORTANT If you have questions or problems with installation contact
13. his hood if it has been damaged dropped has damaged electrical conduit or wires or is not working properly If the product is damaged when received immediately contact the dealer or builder 2 Use this range hood only for its intended purpose as outlined in the use and care manual Do not use this range hood to vent hazardous or explosive materials or vapors If you have questions contact the manufacturer 3 The customer should not install repair or replace any part of the range hood unless specifically recommended in the literature accompanying it A qualified service technician should perform all other service Contact the nearest Dacor authorized service representative at 800 793 0093 or at www Dacor com for examination repair or adjustment 4 Keep all packaging materials away from children Plastic bags can cause suffocation 5 This range hood must be installed and grounded by a qualified installer according to these installation instructions All installation work and electrical wiring must be performed in accordance with all applicable codes and standards including fire rated construction 6 Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range Improper installation adjustment alteration service or maintenance can cause serious personal injury or property damage Do not use an extension cord or adapter plug with
14. liance e Do not touch any electrical switch or use any electrical devices including the telephone in your building e From a neighbor s phone immediately call the gas supplier Follow the gas supplier s instructions e If you cannot contact the gas supplier call the fire department IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline on or in the vicinity of this or any other appliance Also keep items that could explode such as aerosol cans away from the cooktop Do not store flammable or explosive materials in adjacent cabinets or areas including above and below the cooktop WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel READ AND SAVE THESE INSTRUCTIONS dacar WARNING MPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire electric shock serious injury or death when using your range hood follow basic safety precautions including the following 1 Do not install or operate t
15. ment Avoid long drapes or other window coverings that could blow over the cooktop and hood resulting in a fire hazard 17 Always run the blower s whenever the cooktop is operating 18 Never leave the range or cooktop unattended when a burner or element is in use Boil overs and greasy spills may smoke and or ignite 19 Do not leave children alone or unattended in the area where the cooktop and range hood are in use Never allow children to sit or stand on an appliance Do not let children play with a range cooktop or range hood Do not store items of interest to children above or around the cooktop range or range hood 20 The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less than 30 762 mm The vertical distance may be longer for the range or cooktop being used Consult the range or cooktop installation instructions for the minimum and maximum vertical distance from the appliance being used 21 A minimum of two people are required to safely install this appliance 2 Cacor MPORTANT SAFETY INSTRUCTIONS WARNING 22 TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN you may be burned DO N
16. od wired and grounded according to these instructions and in accordance with all applicable electrical codes see page 11 Are the filters properly installed according to the use and care manual Has proper operation been verified Have any problems been noted on the warranty card or during the on line warranty activation Has the warranty been activated on line or the warranty card filled out completely and mailed gacor The Life of the Kitchen Dacor e 1440 Bridge Gate Drive Diamond Bar CA 91765 e Tel 800 793 0093 e FAX 626 403 3130 e www Dacor com
17. r range dacor 3 KENN eR INNIN VERIFY THE PACKAGE CONTENTS ee a neon or A CE damaged please contact the dealer immediately Do not install a damaged or incomplete appliance Hood assembly with filter s Chimney assembly 2 piece Mounting bracket Blower exhaust cowling 2 blower units only Framework assembly 2 piece Mounting and assembly hardware Use and care manual Make sure you have everything necessary for proper g installation before proceeding fol a mlolo a gt 4 gacor LEZNI E INNON WARNING e The electrical service to the range hood should be installed only by a licensed electrician e Observe all governing codes and ordinances during planning and installation Contact your local building department for further information e D NOT use the mounting anchors provided with the unit They are part of a standard mounting hardware package provided with many Dacor hoods but not suitable for use with this model e The range hood is heavy To prevent personal injury and property damage caused by the hood coming loose from the ceiling mount the hood mounting bracket only as specified below PLANNING THE LOCATION e Carefully check the location where the hood is to be installed The hood should be placed for convenient access Make certain that electrical power can be provided in the selected location e Install the range hood and cooking appliance s so that they can be
18. rom the distance measured 12 Put the top framework piece over the bottom framework piece The mounting slots on the top piece must be up 13 Use four machine screws to fasten the top piece to the bottom piece The total height of the two pieces together must equal the required framework height determined above 14 Remove the protective plastic covering from both TOP pieces of the chimney assembly Do not remove the FRAMEWORK protective tape strips from the inside They protect the MOUNTING telescoping pieces from scratching during installation SLOTS 15 Carefully slide both sections together so that only the Re vents on the top section show 16 Hold the chimney vertically with the vents up 17 Carefully put the chimney over the top of the aa framework taking care not to scratch the surfaces Xs Make sure the Dacor logo faces the same side as the Ss control panel 18 Make sure any wires are tucked in behind the chimney and are not pinched BOTTOM dacor 9 INSIENIPENIO N IE INOT HANGING THE RANGE Hoop INSTALL THE Duct Work WARNING WARNING e To prevent personal injury do not rely on the e Do not use screws to attach the duct work to the mounting springs to hold the hood assembly in place hood exhaust outlet Use duct tape only Screws may on the ceiling Once the hood is hooked in place prevent the damper flaps on the top of the hood from IMMEDIATELY secure the framework to the mounting opening bracket as
19. this appliance Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 9 When cutting or drilling into the wall or ceiling do not damage electrical wiring and other hidden utilities 10 The installer must show the customer the location of the fuse or junction box so that the customer knows where and how to turn the power off 11 Before installing or servicing the range hood switch power off at the fuse or junction box and lock the electrical panel door to prevent power from being switched on accidentally When the electrical panel cannot be locked securely fasten a prominent warning device such as a tag to the service panel 12 Read the use and care manual completely before using the appliance 13 Do not tamper with the controls 14 Never allow the filter s to become blocked or clogged Do not allow foreign objects such as cigarettes or napkins to be sucked into the hood 15 Clean the filter s and all grease laden surfaces often to prevent grease fires and maintain performance 16 If the cooktop and range hood are near a window use an appropriate window treat