1. STEP 3 Scanning Techniques Matching Scan Resolution to Purpose Plug in Module CS U provides many choices of resolution The resolution you choose should depend upon your output device the intended purpose of the image the type of image and your scanner It is generally recommended that you scan at a higher resolution than required for output This ensures that you obtain the best quality image which can then be reduced with an image editing program to suit specific purposes Different types of images require different scan settings However increases in scan resolution have a diminishing return after a certain point For example a text image can be scanned at 600 dpi for output to a 600 dpi laser printer while a color image should be scanned at 180 dpi to be output to a color bubble jet printer 360 dpi To output a color or grayscale image to a bubble jet printer use a resolution equal to half the resolution of the printer Set the resolution to 180 dpi for example for output on a 360 dpi printer e Scan in Black and White mode if you are scanning line art or other items that are Black and White with no shades of gray e Scan in Black and White mode if you are scanning a text image for conversion to editable text e Scan in 8bit Grayscale mode if you are scanning continuous tone Black and White photographs charcoal drawings or originals with shades of gray e Scan in 24bit Color mode if yo
2. v Recommended ColorSync None Tone adjustment THIS EISE IMESGIITACICUUEEPNEEA None v Unsharp Mask Hard v Standard High speed Scan Mode Adjusting Scanned Images Scanned images may be corrected for brightness and color tone or edited in a variety of ways The potential adjustments vary with the scan mode utilized in the preview Adjustments to the scanned image may be made after the image is previewed 8 bit 14 16bit Grayscale and 24 bit 42 48bit Color Black amp White 24 bit Color Tone Adjustment E Histogram Settings Tone Curve Settings Brightness and Contrast Settings E Adjusting Color Balance Gamma Value Settings 3 Adjusting Threshold Value 43 Auto Tone Correction ColorSync EE Unsharp Mask m Descreen High speed Scan Mode 3 Saving Recalling Settings Scanning Techniques gt p gt p gt p gt p gt p gt p gt p gt p gt p gt p gt p gt p gt p 40 41 44 47 49 50 52 53 54 55 56 57 59 STEP 3 Tone Adjustment Use Tone Adjustment to enhance the brightness or color of the image in the preview area Open the Image menu and select Tone Adjustment or click the Tone Adjustment button to open the Tone Adjustment dialog so you can enhance the preview image You can al
3. STEP 3 Saving Recalling Settings The scan mode resolution and preference settings can be saved with a preview image to a settings file and recalled for future processing The user may freely assign a name to the settings file It is convenient to save frequently used settings in a file e n addition to settings the settings file may also be used to store preview images It is useful to save the preview image with the settings to quickly grasp to which image the settings apply To Save Settings in a Settings File bP Open the Setting File menu and select Save Setting File Save P Specify the folder where you want to store the file and enter a name for it C Settings EnglishHD CananPl C5 U 4 1 Setting Eject Desktop m Save as CanonPl C4 4 1 Setting ki Save preview image Insert a check mark by clicking this box to have a copy of the preview image saved with the settings file P Click the Save button To Recall a Settings File p Open the Setting File menu and select Load Setting File Select the folder where the file is stored and click the name of the file you want to load Cj Settings EnglishHD CanonPI CS U 4 1 Setting Eject CanonPl CS U 4 1 Setting 2 Desktop Cancel Click the Open button The file you selected opens and the settings stored in the file are enabled for the Tone Adjustment settings
4. Resolution l Click the up or down arrow to Magnification increase or decrease the setting Click here to return the Click inside these boxes magnification factor to 100 to enter values directly Hint The Relationship Between Data Volume and Scanning Resolution The higher the magnification and scanning resolution settings the greater the file size of scanned images There are certain inconveniences associated with large data volumes such as longer processing times and the risk of running out of memory resources You are advised against setting the resolution higher than necessary For example if you scan an A4 21 0 x 29 7 cm 8 3 x 11 7 in size image in the color mode the amount of data varies according to the resolution lI A4 color image 25 5M E 1 6MB 75dpi 150dpi 300dpi 600dpi 1200dpi These numbers are approximate and may differ from actual scan results p Setting the Scan Mode When an image is scanned it is read as a collection of dots The scan mode that is selected determines how each of these dots is represented in the output The following four scan modes are available Black and White Expresses images in two colors only black or white A dot is expressed as either black or white according to its brightness level and the value set as the threshold value which can be freely set Select this mode to output to a mono
5. 3 Image Size 2 3 x 300 in Magnification Required Free 36 4 949 6 mb Required Free 9 1 949 6 mb changed to Magnification 50 The scanning resolution changes Scanning Resolution accordingly Hint Magnification and Resolution Why does the image size change with the magnification Let us answer this with an example using a BJ 720 dpi output device If you were to scan an image with this device setting and set the magnification factor to 50 the scanning resolution will automatically change to 360 dpi At this setting the image will be scanned at a resolution of 360 dpi and the output device will convert this to 720 dpi shrinking the size of the output in the process because it will only have half the data with which to fill the space E Image size 5 x5 Image size 2 5 x2 5 12 7 x 12 7cm 6 35 x 6 35cm Magnification n 50 at Output device 360 dpi corrects to 720 dpi To Set the Magnification Factor b Set the desired magnification factor on the control panel 1 Canon plug in module CS U 4 1 Setting File Image Preferences Film Scan Mode E 24bit Color v Output Device BJ 180dpi v Resolution c 180 Elan Magnification 10d Image Size 1 386 1 899 px Required Free 7 7 2 095 9 Canon Plug in module CS U 4 1 Slider Drag the slider bar in either direction or use the arrow keys to change the resolution
6. Gamma value Plug in Module CS U and the screen display have different gamma values During a scanning job Plug in Module CS U receives the image read from the scanner as input and sends it to the parent application as output The gamma value in this interval where Plug in Module CS U converts input to output is the Plug in Module CS U gamma value On the other hand the data received from Plug in Module CS U as input is sent to the screen display as output The gamma value in this interval where the image input from Plug in Module CS U is converted to output for the screen display is the screen display gamma value Setting the screen display gamma value causes the scanner gamma value to be calibrated automatically as the inverse value For example if the screen display gamma value is set for 1 8 then the scanner gamma value is calibrated for 0 56 the inverse of 1 8 Hint e Please read the documents shipped with your display or contact the manufacturer s customer service department to obtain the correct gamma value for your particular display model e f you intend to adjust the color tone with ColorSync change the settings in the ColorSync control panel found within the Control Panels folder and do not manually change the gamma value settings as described in the following pages STEP 3 To Change the Gamma Value Settings b Click the gamma tab in the Tone Adjustment dialog P C
7. 2 2 eE U Image Size 554 759 pz RequiredFree 1 2 4 2 10959 mh Canon Plug in module CS U 4 1 Buttons Click the appropriate button to zoom rotate or browse the image or correct colors adjust the histogram or start the preview or scan The image size and disk size that were Preview Window specified in the preview window are Displays the image in preview mode automatically displayed here Operating Procedures The following provides an example of scanning from within Adobe Photoshop LE b Verify that the scanner is attached to your computer and that the power IS On Read the Getting Started guide for instructions on how to connect the scanner Start Adobe Photoshop LE Select Plug in Module CS U from within Adobe Photoshop LE Open the File menu select Import and CanonPI CS U 4 1 0 The Plug in Module CS U control panel will display dI Edit Image Layer Select Filter View Close Save 5 Save As i5 Save a Copy S5 Revert Canon plug in module 5 0 4 1 gfe image Preferences Lii Aes oe ee foes Sian Hode Ba Z4bit Cobor ki Import k XCanonPI CS U 4 1 0 BeLa ees Export H PICT Resource Resolution j Magnification gs Twain ACQuire Page setup t PFP Twain Select image Size s54 753 p Print P RequiredPree 127 20959 mb Preferences b EE Caution e Plug in Module CS U is not a stand alone application progra
8. A color set of red green and blue the three primary colors of light The scanner picks up light reflected off objects with its red green and blue sensors Color printers output color using the complements to the RGB color set which are cyan magenta yellow and black CMYK Cyan magenta and yellow are called the three secondary colors Scan Mode Any one of the various methods used to reproduce image data Scan modes are distinguished by the number of bits used to describe each pixel Plug in Module CS U features the following scan modes e 24 bit Color assigns 8 bits of data for each color channel RGB in each pixel Each pixel is therefore assigned 24 bits e 42 48 bitColor While the Color mode scans at 8 bits per RGB channel this mode scans at 14 or 16 bits per channel to achieve a particularly high quality image Each pixel is expressed with 42 or 48 bits of data e 8 bit Grayscale assigns 8 bits of data to its single color channel Each pixel is therefore assigned 8 bits e 14 16 bit Grayscale While the Grayscale mode scans at 8 bits this mode scans at 14 or 16 bits to achieve a particularly high quality image Each pixel is expressed with 14 or 16 bits of data e Black and White assigns 1 bit of data to each pixel Scanning The process of using a scanner to read image data Scanned data is sent to the computer as image data Shadows The darkest portions of an image scanned in a col
9. Photoshop vi Scanning Film Use the following procedures to scan films when the Film Adapter Unit FAU S12 FAU S13 option is attached Caution e Please see the Film Adapter Unit documentation for installation and film placement instructions Operating Procedures Insert the film into the film guide and place the assembly on the scanner s document glass platen Close the film adapter unit P Open the Preferences menu and select Film e The shape of the preview area will change to a square and you will be able to select the Film Settings option from the Film menu Preferences Output Device Aspect Ratio Unit Preview Window Shut off lamp time Resets Default Settings Close Plug In After Scan v Platen Canon plug in module CS U 4 1 Setting File Image Preferences Film Scan Mode E 24bit Color Output Device File 600dpi v Resolution F El dpi Magnification El Z Image Size 850 562 px Required Free 1 4 2 095 9 mb Canon Plug in module CS U 4 1 Open the Film menu and select Film Settings Kim p Select the appropriate film type and size e Click beside the positive or negative film option and one of the 35 mm 120 format and 4x5 inch sizes as appropriate Also set Auto Exposure option on or off Film Settings Film Type amp Color Negatives Black and White
10. U quits antomatically Hint sss e The scan button cannot be clicked if the scan area is set too small less than 64x64 pixels or not specified e The scan cannot be performed if the required memory is larger than the free disk space Saving Scanned Images Follow this procedure to save a scanned image with the parent software application The example below shows how to save a scanned image with Adobe Photoshop LE See the Adobe Photoshop LE Users Guide Operating Procedures After an image is scanned the image is displayed as Untitled When you save the image you can give the file a name and select the folder where it is to be stored b Open the File menu and select Save As The Save dialog will open File Cj Adobe Photoshop 5 0LE EnglishHD Hl Adobe Photoshop 5 0 LE 3 Goodies C3 Help 9 License Agreements Save a Copy Revert Import Export Page Setup Print Preferences Adobe 0nline Quit To select a folder click the arrow and select the name of the folder in which you want to save the file w My Albumi Adobe Photoshop 5 0LE c2 EnglishHD E Desktop Eject Save this document as Format Photoshop v P Enter a name for the file and click the Save button EnglishHD Eject Save this document as Can save J Enter a file name here Format
11. each or all of the primary colors red green and blue RGB Adjust the color by dragging the slidebar left or right Click the up or down arrow in the spinbox to increase or decrease the number value or enter a number directly into the entry box 127 127 The Tone Adjustment settings can be saved in a file and reloaded for later use To restore all the default settings click this button To restore the color balance default settings click this button P Click the OK button STEP 3 Gamma Value Settings By adjusting the gamma value you can more closely match brightness of the displayed image to the printed image Adjust this value if what you see on the screen is very different from your printout Hint e You cannot use this feature with the black and white scan mode or with the color scan modes when ColorSync is selected Matching the Gamma Value to the Display Characteristics Not all screen displays reproduce color tones in exactly the same way and this reproduction method is expressed as a gamma value from 1 4 to 2 2 and normally reproduces a slightly dark image In order to avoid this and reproduce an image that is faithful to the original the gamma value must be adjusted in Plug in Module CS U Plug in Module CS U can adjust the pre set screen gamma value of 1 8 but if the screen has a gamma value other than 1 8 then the gamma value for that screen must be set
12. eee eee uuu OU 30 ull uu 31 seme cere nuan usss nata EEE 23 Saving Scanned Images sssssssssssssssseenee Imm ne nn nnn enhn nnne nins nnns 34 ii TW u u u uD uuu u n m s 35 Remove Dust and Scratches CanoScan D2400U only 38 STEP 3 WISE S S Ee Adjusting Scanned Images IA D Ai uu uu y u uzun u n 40 PU S POC SU uy u E ea etewncuaieseebeseo nag sata nhunieteanar yee tae ooneateiess 41 ORS GS 5 SING M Tr 44 Brightness and Contrast Settings ssessssssssssssssss emnes 47 Adjusting th Color Balani E uuu muc dta tuat ap dicebatur 49 Gr ni vale SONT IRIS CRT EP 50 Adjusting the Threshold P MER ERUNT s AUO TONO C e een T EET 23 Nicias doni c A RRRT 54 PESCE e E Z eee 55 zeige ome n IV OO u RE 56 Saving Recaling SeN EE NO E By SCANNING Tespnrl ll s uuu ku A etd Erotic Deben sakaasa dude ayspshakasaq 59 APPENA S e uu uu e FIN MEI A DUE FIN UENIRE NINE E RM EMUNS 60 TOUDE NOGUN uuu u u uu pra usus sanassssawaaqunaq ukasa ubuspaquamayasakasaququmawksamawanassuiasnna 61 r Ori uyu xu xn n 2 s ay mai u una at a nesa 65 O 66 ll EP E ss S ene S s Su anus n T 71 Canon Customer SUpport Help Der uuu usss 73 No part of this guide may be reproduced transmitte
13. of the Image to be Scanned gt p 30 Select the area to be scanned by clicking and dragging the mouse pointer over the image e You may find it convenient to use the zoom feature to select small areas or to select specific scan areas with precision p 31 E Canon pbug in module Cs LU 4 1 Hagnificatian Image Size ps Requirad Fraa 274 2095 w02 kb Scan the Image gt p 33 Click on the Scan button e Plug in Module CS U will scan the image Canon plug in module Cs U 4 1 setting File Image Preferences Film Scan Mode DutputDevice onra Resolulion W 1a dBi Magnification iog image Size 2882384 p Required fron 27a 2 095 goalie anw Cura Pherin pashka CS 4 1 e When the scan is complete close the Plug in Module CS U control panel The scanned image will appear in the Adobe Photoshop LE or other plug in compatible application window as an Untitled file Progress Oo Untitled 1 100 RGB EJ amp Import Canon PI CS U 4 1 LLL cancel Save the Scanned Image p 34 Save the image with Adobe Photoshop LE or other plug in compatible application specifying a folder and file name When the amount of light of the lamp inside the scanner is insufficient the message Now adjusting lamp may be displayed Wait as is until the amount of light increases enough Scanning Preparati
14. red green and blue RGB light and can reproduce each one of these three colors in 256 distinct tones 8 bits Since 256 x 256 x 256 approximately 16 7 million this many color tones are possible in this mode ColorSync A color management system for Macintosh computers Automatically compensates for color differences between scanners monitors and printers ColorSync requires that a color profile file be included for your specific monitor or printer Contrast The difference between light and dark areas of a scanned image Raising the contrast makes individual components of an image stand out more while lowering it softens the image s overall appearance Dot The basic element used to reproduce images Images are reproduced as columns and rows of dots A scanner s resolution is the measure of the number of dots it can read and reproduce per inch dpi DPI Dots per inch An expression of monitor and printer resolution Measured as the number of dots per horizontal inch on monitors and the number of dots that can be printed by a printer in an inch See also Pixel Optical Resolution and Resolution Gamma Value A function for adjusting the overall brightness of an image A gamma value is the mathematical expression of how brightness data is converted from a scanner the input to a monitor or printer the output With 1 as the base value a gamma value less than 1 makes an image darker while a higher value makes it brighter T
15. scan that encompasses the entire scanable area of the document glass The preview image is shown in the oc preview window Use this image to specify a scan area and adjust the scan settings for the image Operating Procedures Click on the Preview button e The image will be scanned and appear in the preview window Canon plug in module CS U 4 1 Setting File Image Preferences Film Scan Mode E 24bit Color Dutput Device CRT 72dpi Resolution p 7 joni Magnification Es Image Size 965 799 px Required Free 1 3 2 095 9 mb m 9 Preview 4 Scan m 9 4 1 Hint e To change the size of the preview window use the Window Size settings in the Preview Window Settings dialog p 26 e The Dynamic Preview function enables changes to settings such as the scan mode and brightness to be immediately reflected in the preview image Caution e The preview image provides only an approximation of the scan and the final results may differ to some degree from it e Calibration automatically starts when Preview or Scan button is clicked Selecting the Output Device Use the following procedures to select the output device printer etc for the scanned image Select the device that corresponds best to your output device and use of the image Operating Procedures Click the arrow on the Output Device section of the control panel and se
16. size 20 Free memory 7 G Gamma tab 51 Gamma value 50 67 Grayscale 68 H Highlight mark 42 Highlights 41 Histogram 41 68 Histogram tab 42 Image file 68 Image menu 40 Image size 7 Install 6 10 L Load Settings file 53 M Magnification 7 11 19 20 68 Menu bar 14 Moir 55 68 O Optical resolution 59 68 Output device 7 11 18 25 59 P Pixel 69 Plug in Software 69 Preferences 25 Preview 17 Preview area 69 Preview button 7 17 Preview scan 17 69 Preview setting 26 Preview window 7 14 17 26 Preview window size 26 R Recall settings file 57 Required memory 7 Reset Default Settings 27 Resolution Z 11 19 69 RGB 14 69 RGB values 14 Rotating the image 24 Rotation button 7 24 S Save Scanned image 12 34 Save Settinos file 57 Scan 12 33 Scan area 11 30 Scan button 7 12 33 Scan Mode Black and White 21 Color 24 42 48 bit 21 Grayscale 8 14 16 bit 21 Scan mode 7 11 21 70 Scanning 70 Scanning resolution 19 59 Screen gamma value 51 Settings file 57 Shadow mark 42 Shadows 41 70 Special features 9 Start Plug in Module CS U 70 T Threshold 52 Threshold value 52 70 Tone Adjustment 40 Tone Adjustment button 7 40 Tone Adjustment dialog 36 Tone curve 44 70 Tone curve tab 45 Tone curve value 46 U Unit 26 Unsharp mask 54 70 W White Eyedropper button 43 White Eyedropper tool 70 Z Zoom In button 7 Zoom Out button 7 Zooming 31 Zoom
17. you use these settings check the specifications to determine whether or not 14 16 bit Grayscale and 42 48 bit Color scanning is supported Adobe Photoshop Ver 3 0 or later and Adobe Photoshop LE supplied with this package support these modes e f you scan an image with a version of Adobe Photoshop compatible with 42 bit Color a 14 16 bit Grayscale or 42 48 bit Color image is scanned as a 16 bit Channel Mode image e 14 16 bit Grayscale and 42 48 bit Color images generally cannot be printed without modification To print them out first transform them into 8 bit Grayscale or 24 bit Color images respectively Verifying the Image before Scanning Before initiating the final scan it is advisable to check the intended results with the Browser function The image in the browser window is more accurate than the one in the preview window allowing you to verify the results more precisely before scannino To Verify the Image p P Set the magnification and scan mode to the appropriate settings Click on the Browser button e The selection frame will appear in the preview window to enable a portion of the image to be selected e The size and shape of the selection frame cannot be changed because it is automatically determined by the scanning resolution Canon plug in module C5 U 4 1 Setting File Image Preferences Film Scan Mode E 24bit Color E Output Device BJ T8 dpi E E Resolution 180 a
18. LAND GmbH Postfach 528 47705 Krefeld Germany CANON Hotline Service Customer Support 0 21 51 349 555 Info Desk 0 21 51 349 566 Mailbox 0 21 51 349 577 Telefax 0 21 51 349 588 CANON ITALIA S p A Palazzo L Strada 6 20089 Milanofiori Rozzano MI Italy TEL 02 8248 1 FAX 02 8248 4604 Pronto Canon 02 8249 2000 http www canon it CANON BENELUX NEDERLAND N V Neptunusstraat 1 2132 JA Hoofddorp The Netherlands Tel 023 5 670 123 Fax 023 5 670 124 Helpdesk 023 5 681 681 CANON BENELUX BELGIUM N V S A Bessenveldstraat 7 1831 Diegem Belgium Tel 02 7220411 Fax 02 7213274 Helpdesk 02 7220404 CANON GmbH Zetschegasse 11 1232 Wien Austria CANON SCHWEIZ A G Industriestrasse 12 CH 8305 Dietlikon Switzerland Tel 01 835 61 61 Fax 01 835 68 60 Hotline 157 30 20 CANON ESPANA S A C Joaquin Costa No 41 28002 Madrid Spain Help Desk 906 301255 Tel 91 5384500 Fax 91 4117780 CANON DANMARK Vasekaer 12 DK 2730 Herlev Denmark Hotline 44 88 26 66 http www canon dk CANON NORGE AS Hallagerbakken 110 Boks 33 Holmlia 1210 Oslo 12 Norway Tif 2262 9321 FAX 2262 0615 CANON SVENSKA AB Gustav IIl s Boulevard 26 S 169 88 Solna Sweden Tel 08 744 85 00 Fax 08 744 64 65 http Awww canon se CANON OY AB Kornetintie 3 00380 Helsinki Finland Puhelin 010 544 20 Helpdesk 0600 0 22606 maksu 14 80 mk min Fax 010 544 4571 CANON SINGAPORE PTE LTD 79 Anson Road 09 01 06 Si
19. Negatives Color Positives Black and White Positives Film Size 35mm Sleeve 35mm Mount 120 Format 4 5x6 120 Format 6x6 120 Format 7x6 120 Format 8x6 120 Format 9x6 120 Format 12x6 Q 4x5 M Auto Exposure Save Exposure Data Auto Exposure This function is available when Film is selected When On this function automatically sets the exposure data light intensity and compensation for each RGB channel to match the brightness of the film and produce the best scanned image The default setting for this function is On Set it to Off when you wish to perform the exposure compensation with an application program after the scan or if you wish to achieve an under exposed effect Save Exposure Data This function is available when Film is selected and Auto Exposure is set to On If a check mark is placed beside this option you can scan a new film using the exposure data from a prior film If for example a film is shot under the same lighting conditions and settings as another several frames can be scanned with the same exposure data making it possible to achieve finely matched color tones Caution e Please set the area so that it fits within the boundaries of the selected film size when Auto Exposure is set to On If it extends beyond the edges of the film or is too small the auto exposure function will not operate correctly e At low temperatures the preview scan may take som
20. a volume indicated on the control panel The numerator indicates the amount of Image Size 1 386 1 899 px disk space required for the scanned image i p equired Free 7 7 2 095 9 mb while the denominator indicates the amount of disk space available When the required space exceeds the available space fay wie KONE or 2GB the scan button is unavailable Canon Plug in module CS U 4 1 Operating Procedures b Click the arrow beside Scan Mode Canon plug in module CS U 4 1 Setting File Image Preference Fili Scan Mode E Selecting the box opens x a 2 output Device Bet V lz T Resolution Q p 180 api Magnification odz Jg l EF Preview Scan r Canon Plug in module CS U 4 1 N Black amp White E 8bit GrayScale Setting File 1 9 E 16bit GrayScale Scan Mode Paez dimes WB 48 bit Color Dutput Device BJ 180dpi LT Resolution y 180 180 dpi Magnification Es Image Size 1 366 1 899 px Required Free 7 7 2 095 9 mb wid llis e Preview Scan Canon Plug in module CS U 4 1 Caution e f you select 14 16 bit Grayscale or 42 48 bit Color for a software applica tion that does not support these options the system may hang up when you attempt to execute the scanning job with either selection Before
21. alled Click the Cancel button to close the dialog Detach the scanner and install the required software from the CanoScan Setup Utility CD ROM before reattaching the scanner gt Quick Start Guide Plug in Module CS U does not appear as an option on the menus of a plug in compatible application program Plug in Module CS U is not correctly installed on your hard disk drive Reinstall Plug in Module CS U gt Quick Start Guide The image will not appear even if the Preview button is clicked on the Plug in Module CS U control panel Solution 1 Make sure the original is set on the document glass correctly Solution 2 The brightness settings for Plug in Module CS U may be set too high Try lowering the brightness settings For details about brightness setting see Brightness and Contrast Settings gt p 43 Solution 3 The threshold setting for Plug in Module CS U may be set too high Try lowering the threshold setting For details about setting the threshold setting see Adjusting Threshold Value gt p 48 e Problem Scan button cannot be selected Solution 1 A scan cannot be performed if the scan area is set too small less than 64 x 64 pixels Increase the size of the scan area Solution 2 A scan cannot be performed unless a scan area is specified Specify a SCan area Solution 3 A scan cannot be performed if the required memory is larger than e Problem the free memory Change the re
22. alog you will the tabs you will see when color or grayscale see when black and white is selected as the has been selected as the scan mode scan mode Only one tab is available Quy STEP 3 Histogram Settings m The data comprising an image contains a variety of brightness settings ranging from shadows to highlights These settings are represented in Plug in Module CS U by values ranging between 0 and 255 The difference in these values determines the image s contrast To show how much of the image data falls into each brightness setting Plug in Module CS U contains a histogram feature that shows this data distribution clearly With the histogram you can adjust the level of shadows and highlights to achieve beautiful tones with the best possible contrast Hint e You can enhance images with the histogram options only when the image has been previewed in the color or grayscale scan modes e You cannot enhance the image with the histogram when ColorSync is selected How to Interpret Histograms You can select the entire image or specify an area for which a histogram will be generated The height of the peaks of the histogram is directly related to the volume of data with the corresponding value Portion with Highlights Distribution of data with a bias toward highlights Portion with Shadows Distribution of data with a bias toward shadows Distribution of da
23. am after scanning This mode is most appropriate for advanced users Caution e This function is available only when the scan mode is set to one of the color modes not to the grayscale or black and white modes e The Tone Adjustment menu item Tone Adjustment button and Auto Tone Adjustment button are disabled when the ColorSync option is selected e The previous settings are in effect when Plug in Module CS U is started from an application program that does not display the Plug in Module CS U control panel Hint e ColorSync responds differently to each computer according to the unique conditions affecting it type of display used etc which may cause differences even between computers of the same make and system version The tone characteristics of an image scanned with ColorSync on one computer therefore may change when processed on another computer To Set the Auto Tone Correction Open the Image menu and select Recommended ColorSync or None Tone adjustment Descreen v Unsharp Mask High speed Scan Mode A check mark will appear beside the selected option which will take effect STEP 3 Unsharp Mask The Unsharp Mask function enhances the outlines of an image When set to On this function makes the image outlines appear sharper without changing the brightness contrast or color balance giving it a natural look It is particularly useful for scanning images that are slightly out
24. anning Step 2 presents the procedures for conducting the final scan saving the scanned image in a file and editing image files Follow the procedures below to perform the final scan m Setting the Scan Area gt p 30 m Zooming gt p 31 v EE Scanning gt p 33 v mm Saving Scanned Images gt p 34 Scanning Film gt p 35 Setting the Scan Area Using the image in the preview window you can define the actual area to be scanned Operating Procedures Position the pointer in the preview window The symbol marks the current position of the pointer Click and drag the mouse in the direction you want to define on the image as a frame The selected area is enclosed in a dotted frame The area enclosed in this dotted frame is the area that will actually be scanned Eu _ Canon plug in module CS5 U 4 1 Setting File Image Preferences Film R 255 255 GiZ55 255 B 255 255 Scan Mode EB 24bit Color Ea Output Device BJ 180dpi E E Resolution z teo Gap r Magnification joo Jz Image Size 657 954 ps pm YY 1 8 2 995 9 mb Canon Plug in module CS LI 4 1 e You may drag the frame in any direction e Clicking the mouse button outside the selection frame causes the selected area to be deselected e Moving the mouse cursor within the selection frame changes it to an omni directional arrow Dragging the cursor in this state w
25. avoid errors Hint This symbol is used to present helpful hints and supplemental information Reading these topics is recommended to enhance your enjoyment of Plug in Module CS U Table of Contents How to Make Best Use of the Manuals ssssessssee 2 How to Use thie NC 3 Te ONEI e E EO 4 Installing Plug in Module 4 0 a aaasrnnnrssnsssrasssrrrasssiiiaasa 6 CORON Panel FOG AEC uu uuu E A E E EE 7 Scan iO G lie uu enna ns nee E sss m 8 Plug in Module CS U Special Features sesssssesse 9 Quick Start Instructions 10 st Scanning Preparations 13 Displaying the Plug in Module CS U Control Panel 14 OS WO UCL il GUS MONROE 16 3127 79 u u Sumu asa 22 I7 AEE eO u DEVE RUN m ET 18 Setting the Resolution and Magnification r aa a aarr 19 Ilo Ne aN MOUS qu EE 21 Verifying the Image before Scannin0 e 23 POA dg cd aar e NE 24 SQ BETREUER 25 GUI UM 2 had s 29 Sp OoO 26 uiu Ane T C 26 peset Dio 72 BL 18 IR IO SERERE S 27 STEP 2 TU S lilii u uuu uu n usss 29 I l e icc
26. cannot use this feature with the black and white or color scan modes when ColorSync is selected Contrast Contrast is the difference between the lightest light and the darkest dark in the image A high contrast setting creates a great difference between light and dark shades and there is a very sharp distinction between light and dark areas of the image A low contrast setting creates a small difference between light and dark shades and the distinction between light and dark areas of the image are not as obvious Contrast 128 Normal Contrast 170 Contrast 100 If the image appears slightly out of focus increase the contrast setting to sharpen the image If the contrast setting is too high shadows will blacken and the highlights will wash out Brightness Brightness is the overall lightness or darkness of an image without changing the contrast Adjust the brightness setting to change the overall lightness or darkness of the entire image If the brightness setting is too high the highlights will wash out and if too low the shadows will blacken Brightness 128 Normal Brightness 190 Brightness 80 STEP 3 To Adjust the Brightness and Contrast b In the Tone Adjustment dialog click the brightness contrast tab Adjust the brightness contrast settings by dragging the slidebars changing the value with the spinbox buttons or entering the value directly into the entry box Drag the slidebar left or righ
27. chrome printer 8 bit Grayscale Expresses a dot in up to 256 shades of gray Select this option for scanning black and white graphics and photographs Grayscale 14 16 bit Scans the image with finer tonal gradations Select it when a particularly high quality image is required Grayscale 14 bit 16 384 shades between black and white can be selected with the CanoScan D1230U and Grayscale 16 bit 65 536 shades between black and white with the CanoScan D2400U The data obtained with this setting can only be used with Photoshop LE and certain other applications 24 bit Color Expresses a dot with 8 bits or 256 shades for each primary color red green and blue RGB for a total of 24 bits A dot can be expressed in up to 16 7 million distinct shades Use this option for most color photographs Color 42 48 bit Scans the image with finer color gradations Select it when a particularly high quality image is required Color 42 bit 16 384 colors per RGB channel can be selected with the CanoScan D1230U and Color 48 bit 65 536 colors per RGB channel with the CanoScan D2400U The data obtained with this setting can only be used with Photoshop LE and certain other applications Hint gt Scanning the same image in the four different scan modes produces different file sizes By size black and white mode requires the least disk space followed in order by the grayscale and the color modes Before scanning check the dat
28. d transcribed stored in a retrieval system or translated into any language in any form by any means without the prior written permission of Canon Inc Canon Inc makes no warranties for damages resulting from corrupted or lost data due to the operation or malfunction of hardware and software While every effort has been made to ensure that the information contained in this guide is accurate and complete no liability can be accepted for any errors or omissions Canon Inc reserves the right to change the specifications of the hardware and software described within this guide at any time without prior notice Please take note that international copyright laws prohibit the scanning of copyright protected materials for any uses other than for personal use CanoScan and Canon Plug in Module are trademarks of Canon Inc Macintosh Power Macintosh Mac OS and ColorSync are trademarks of Apple Computer Inc registered in the U S and other countries iMac is a trademark of Apple Computer Inc Adobe and Photoshop are trademarks of Adobe Systems Incorporated Other names and products are trademarks or registered trademarks of their respective companies Installing Plug in Module CS U Please install Plug in Module CS U with the other application programs according to the instructions in the Install the Software section of Using the Macintosh Platform of the Quick Start Guide supplied with the scanner Operating Environmen
29. dobe Photoshop LE to expand the capabilities of that program Adding scanning capabilities to your computer is as easy as putting in a pluo Simply copy the Plug in Module CS U files to your computer Please read this guide to perform the installation procedures and scan Store this manual in a handy location for future reference Where to Look Quick Start Instructions p 10 The Quick Start Instructions provide a brief summary of commands and procedures that will assist in using Plug in Module CS U immediately Scanning Preparations Required Reading p 73 All users should read this section This section describes the procedures and settings required before scanning including positioning the original and selecting the output device resolution magnification and scanning mode Scanning Required Reading p 29 All users should read this section to learn the procedures for scanning images and saving scanned images Adjusting Scanned Images p 35 Read this section for details about how to adjust image brightness color balance and other attributes You can read this section as required Appendices Read this section for troubleshooting tips glossary terms and the index About the Conventions Used in this Guide The following conventions are used in this guide to draw your attention to important information Caution This symbol is used to highlight procedural precautions and limitations Always read these topics to
30. e gradations e Gamma Curve Adjusts Image Brightness The Gamma Curve feature provides four methods you can use to refine in detail the level of image brightness until you are satisfied with the results e Works within Image Processing Software for Easy Image Editing Plug in Module CS U can be used to extend the functions of plug in compatible image processing application programs Supports Optional Film Adapter Unit Scans 35 mm 120 format and 4x5 films when the optional Film Adapter Unit FAU S12 S13 is attached Just select the negative or positive film setting and set the film size to effortlessly create color prints with the auto brightness and tone adjustment features Quick Start Instructions Follow the procedures below to start scanning immediately If you require more information at any stage read the pages referenced at each step Install Plug in Module CS U This step is not required if you have already installed Plug in Module CS U following the instructions in the Quick Start Guide 1 Place the CanoScan Setup Utility CD ROM into the computer s CD ROM drive The CanoScan Setup Utility will start automatically If it doesn t double click the CD ROM icon followed by the setup icon 2 Click Install the Software to install Plug in Module CS U and the other application programs Start Plug in Module CS U gt p 14 1 Start Adobe Photoshop LE or other plug in compatible application 2 Open the File m
31. e Descreen function when Plug in Module CS U is opened by a software application operating in the windowless mode Operating Procedures b Open the Image menu and select Descreen Image Recommended Colorsync Mone Tone adjustment Descreen Unsharp Mask High speed Scan Mode A check mark will appear beside the Descreen option in the menu when this function is set to On To set it to Off reselect it The check mark will disappear Hint e When the Descreen is on it may take longer to scan STEP 3 High speed Scan Mode This function is available when the image source is set to Platen When a check mark is placed beside this option scanning can be accomplished faster because the lamp output data auto color adjustment data from the first pass is used for subsequent passes The default setting is Off for this function Caution e When you select Film from the Preferences menu the High speed Scan Mode is not available Operating Procedures b Select High speed Scan Mode from the Image menu Image Recommended Colorsync Mone Tone adjustment Descreen Unsharp Mask w High speed Scan Mode Caution e t may take some time to acquire the lamp output data on the first scan after the high speed scanning mode is selected Similarly the first scan after Plug in Module CS U is started make take some time even when the high speed scanning mode is selected
32. e Preferences Film Scan Mode EB 24bit Color Dutput Device BJ T80dpi Ea Resolution ug 189 Bl api Magnification odz Image Size 254 467 pz Required Free 507 2 095 992 kb wa um Ay Canon Plug in module CS LI 4 1 P Click the Zoom Out button S to restore the view prior to zooming Click the Zoom Reset Button to restore the size just after previewing E Hint e The image cannot be zoomed unless an area is selected e The selection can be zoomed up to six times consecutively If the selected area is too small the Zoom In button will be disabled and the selection cannot be zoomed Scanning scan Once the scan is complete close Plug in Module CS U The scanned image will appear in the application software such as CanoScan Toolbox or Adobe Photoshop LE Once you have set the magnification and scan mode you may proceed with the Scan To Initiate the Scan Specify the Scan Area See Setting the Scan Area p 30 P Click on the Scan button L1 Canon plug in module C5 U 4 1 Setting File Image Preferences Film Scan Mode Ef 24bit Color E Output Device BI 180dpi Resolution P 180 S api Magnification io Az Image Size ado 822 ps Fequired Free 1 3 2 2 095 9 mb Canon Plug in module CS U 4 1 A Ya e The scan will start Click I close box to guit the Plug in Module CS U e When you select close Plug in After Scan the Plug in Module CS
33. e each of its color channels red green and blue can be expressed in 256 distinct color tones 8 bits Black and White An image mode used to reproduce images in two tones only black and white The brightness level at which a dot is determined to be either black or white Is called the threshold value which can be adjusted See Threshold Value Black Eyedropper Tool Tool used to the select the darkest portion of an image in the preview area Used with the Histogram function to adjust image brightness When this tool is clicked on the image all areas that are darker are set to pure black Brightness The intensity of light in a scanned image Raising an images brightness increases Its overall brilliance while decreasing it makes it darker Color Balance The function in that enables you to adjust the blend of colors in a color image You can adjust the color balance by altering the blend of the red green and blue color set or the cyan magenta yellow and black color set Color Channel Any one of the red green or blue elements of a color image Since color images are assigned 8 bits per pixel for each of the red green and blue channels each pixel is assigned 24 bits of data The master channel is the composite of these three channels In the Histogram and Tone Curve image adjustment functions each channel can be separately or collectively adjusted Color An image mode that scans an image as
34. e scanned from books and magazines at low resolutions The Descreen function helps to eliminate moir patterns Optical Resolution An expression of the volume of data per inch dpi that can be sampled by a scanner Pixel An abbreviation of picture element the smallest element on a monitor screen Plug in Software A program that extends the functionality of an application program Plug in Module CS U is a driver plug in that adds scanning capabilities to programs such as CanoScan Toolbox and PhotoStudio 2000 Preview Area Area at the right of the Plug in Module CS U window used to display preview images Clicking the Preview button causes the scanner to scan its platen and reproduce the image in the preview area Please note however that preview images do not get downloaded to the application program in use Preview Scan A low resolution trial scan of an object The image shown in the preview area can be used to adjust the scan area brightness and color balance before initiating the final scan Remove Dust and Scratches This function is available with a Film Adapter Unit FAU S13 equipped CanoScan D2400U It utilizes the properties of infrared light to detect small flecks of dirt or scratches on film and retouches them Resolution The density of the dots used to express an image Image fineness or coarseness is expressed as the number of dots per inch dpi See also DPI RGB
35. e time to start because the fluorescent lamp inside the scanner is not sufficiently warmed If a preview image is too bright or dark in a low temperature environment please perform a second preview scan Pp Preview the film and select the area you want to scan P b Click on the Scan button Canon plug in module CS U 4 1 Setting File Image Preferences Film R 2580 251 G 250 251 B 250 251 Scan Mode Ef 24bit Color Output Device File 600dpi Resolution P eod Bun Magnification B z Image Size 850 562 px Required Free Leet 0959 l z y f Ir Oe P Preview Canon Plug in module CS U 4 1 Set the scan mode resolution magnification and tone adjustment settings as required With CanoScan D2400U Remove Dust and Scratches function is available p 38 Untitled 1 50 RGB Progress Import Canon PI CS U 4 1 x cancel J sow Persas p lt Remove Dust and Scratches CanoScan D2400U only This function is available with CanoScan D2400U and FAU S13 when Film is selected in the Preferences menu and the film type is set to Color Positives or Color Negatives The FARE Film Automatic Retouching and Enhancement function automatically produces a scanned image with the areas under small bits of dirt or scratches removed The available settings are None Soft S
36. enu select Acquire and CanonPI CS U 4 1 0 Position materials for scanning and preview them 3 p 16 1 Position an item on the document glass platen 2 Click the Preview button e The entire scanable area of the document glass will be previewed and displayed in the preview window is Canon plug in module CS U 4 1 H Setting File Image Preferences Film Scan Mode BIB 24bit Color M Output Device CRT 72dpi M Resolution z3 joi Magnification iod Required Free _ 13 20959 mb Canon Plug in module CS U 4 1 Set the Scan Mode Output Device Resolution and Magnification pp 18 22 e Scanning mode determines how the image is scanned p 21 e Output device setting optimizes the images for particular uses p 18 e Resolution determines the amount of detail in the scanned image p 19 e Magnification determines the amount of enlargement or reduction of the output image display p 79 Verify Image Quality with the Browser Function before Scanning gt p 23 1 Click on the Browser button al 1 Soan Hoda Zibi Color w ut Device CHIL7Zdpi 2 Move the selection frame to specify the area of the image you want verified and click the mouse button e Plug in Module CS U will read the image and display the browser image 3 After you have examined the browser image click the mouse anywhere Specify the Area
37. etermines whether or not Plug in Module CS U closes automatically after completion of the scanning job After you install Plug in Module CS U this setting is set to off To turn this feature on open the Preferences menu and select Close plug in after scan Platen Film When a film adapter unit FAU S12 S13 is attached to the scanner the Film option in the pull down menu can be selected Select either Platen or Film to make the respective scanning method effective which is indicated by a check mark in the pull down menu Caution e When switching between the Platen and Film options the scanner has to adjust the lamp output which may require a few moments to take effect Operating Procedures p Open the Preferences menu in the control panel Preferences Output Device Aspect Ratio Unit Preview Window Shut off lamp time Resets Default Settings Close Plug In After 5can Platen i Select the desired option from the pull down menu e Selecting any one of the Output Device Aspect Ratio Unit or Preview Window options displays the respective dialog Choose the desired value in the dialog and select OK to chanoe the setting e A confirmation dialog will display if Reset Default Settinos is selected The settings will be reset if OK is selected in that dialog e You can select either Platen or Film The selected one is checked Sc
38. files scan area setting method size display units Unit s preview window size You can change these options at any Preview Window time or restore the factory default settings To change any dM E i I Resets Default Settings of these options use the Preferences menu Clase Plug In After Scan Film Output Device Adds new output devices or file formats to the pop up menu in the control panel Devices are displayed by name Resolution and other settings can be changed for the devices or the devices can be removed Adds a new device Output Device Name New Output Device ues Resolution W ao api EA OCR 600dpi batan Dp E Allows you to change the name and resolution setting Output Device Settings M File 100dpi M File 150dpi EAFile 300dpi Output Device Name Postcard Pring Resolution so JJ dpi M File 400dpi M File 600dpi M File 1200dpi v Postcard Print 300dpi N Comer J Allows you to remove a device from the list i Hint e The preset devices cannot be edited or deleted Aspect Ratio To set the size of the area to be scanned drag the mouse to size the selection frame in the preview window The area inside the borders of the selection frame will be scanned When the Independent setting is selected the selection frame can be freely resized and reshaped by dragging It When the Constrained setting is selected choo
39. film F ll197194 G10717150 e eea ena p 18 Resolution pp 19 20 p 52 Magnification pp 19 20 Image Size pp 19 20 Required Required Free Free memory p 21 Zoom Reset Button p 32 Zoom In Button Preview Window gt p 14 26 p 31 Scan Button gt p 35 Rotation Button Preview Button gt p 17 gt p 24 Zoom Out Button p 32 Auto Tone Adjustment Button gt p 40 Tone Adjustment Button gt pp 40 52 Image Size Preview Scan Browser Button gt p 25 Hint In this guide menu items are marked in the following manner Setting File 3 Select Load from the Setting File menu Scanning Procedures Follow these procedures to use Plug in Module CS U Is Plug in Module CS U installed Refer to the scanner s CD qo Quick Start Guide to v 4 install it Is the scanner attached Refer to the scanner s CD D Quick Start Guide to v 4 attach it O STEP 1 Prepare for Scanning gt p 13 Position the Original p 16 Preview p 17 Select the Output Device p 18 Set the Resolution and Magnification p 19 Set the Scan Mode p 21 v Verify the Image before Scanning DIESE UE e Browser Window gt p 23 T EP 3 Adjust and Edit Scanned Images v gt p 39 Are the Brightness and Color Satisfactory Histogram p 41 G lt C gt Tone Curve p 44 Brightness and C
40. for Macintosh Canon Solutions anon Plug in Module S U 4 1 for CanoScan DIZ30U D2400U Color Image Scanner Users Guide How to Make Best Use of the Manuals When you open the box CanoScan D1230U D2400U Quick Start Guide Describes operating procedure from set up and software installation to scanning and confirmation of operation Please read before using the scanner for the first time aS Printed Manual du ENTE CanoScan D1230U D2400U Product Guide Describes handling and care of the scanner and introduces the accompanying software programs IEEE Canon Plug in Module CS U User s Guide Detailed information on how to use Canon Plug in Module CS U 3T ETE CanoScan Toolbox User s Guide Detailed information on how to use CanoScan Toolbox After you have read this book and mastered the use of Canon Plug in Module CS U and CanoScan Toolbox When using the accompanying application software Application Software Tells you how to use Adobe Photoshop LE and ScanSoft OmniPage SE How to Use this Guide This guide explains the operating procedures for Canon Plug in Module CS U hereafter referred to as Plug in Module CS U the Macintosh driver pluo in software used with Canon image scanners A plug in is not an independent software program it must be used within a plug in compliant application such as CanoScan Toolbox or A
41. ft com SCANSOFT INC http Awww scansoft com OCANON INC 2001
42. hadows and highlights OUTPUT I E z If you want to invert the shadows and highlights 1 INPUT If the image is in color the colors are switched to their complementary colors STEP 3 To Edit the Tone Curve p P In the Tone Adjustment dialog box click the tone curve tab Change the tone curve in any direction to adjust its shape You can adjust the setting for each To create a control point on the line just click anywhere channel R red G green B blue in the graph After a control point is displayed in the line or M master You can adjust each you can click to move it in any direction As you move it channels independently You can to another location the value changes You can set adjust RGB only for a color image several control points on the tone curve Shows the input and output level at the point under the pointer control point in the graph expressed as a value from 0 to 255 where 0 is the darkest and 255 the lightest If the output level is larger than the input level this results in a lighter image To restore the tone curve default settings click this button To restore all the The Tone Adjustment settings can be saved in a file default settings click and reloaded for later use this button Click the OK button The image in the preview window changes to reflect the new settings STEPS The Relationship Between the Tone Curve and Image Brightness T
43. he Gamma values fall with a range of 0 01 to 10 00 A value of 1 appears as a straight line in the graph and if the value is any value other than one the line on the graph will appear curved The relationship between the shape of the curve and image brightness is explained below Gamma Value 1 Input and output and are equal and the curve appears as a Output straight line and the input nd image is displayed on the screen without adjustment Input Gamma Value 1 ej The data bends upward over s the range of input values from O shadows to highlights making us the adjusted image brighter in the display EE Input Gamma Value lt 1 sl The data bends downward over 5 the range of input values from shadows to highlights making epe the adjusted image darker in the display EE Input CAUTION e The tone curve cannot be adjusted manually in one of the color scan modes when ColorSync is selected because the color balance is adjusted automatically e The tone curve cannot be adjusted for a black and white image because mid tones are shown as either black or white To adjust the brightness of a black and white image use the threshold setting p 48 Brightness and Contrast Settings You can adjust the image with two slide bars one for contrast and one for brightness Use this method to adjust an image before scanning if it is slightly out of focus or too dark ES Hint e You
44. he brightness handling characteristics of monitors vary between manufacturers and models A monitor s gamma value explains the degree to which its output what you see on the screen varies from the input value Grayscale An image mode that scans only the brightness data of an image and reproduces the image in white black and 254 shades of gray 256 tones or 8 bits Histogram A graph indicating the distribution of brightness data in an image A dot is assigned a brightness value ranging from 0 shadows to 255 highlights The histogram shows how much image data there is at each brightness value Adjusting the histogram changes the image contrast Image File Images are expressed as collections of dots with varying color and brightness values that are digitized in particular formats for processing by a computer At the most basic level an image file contains bitmap information which is the color information for each dot in each column and row of an image The various file formats TIFF BMP etc use different methods of storing and recalling this information Magnification An expression of the relationship between the scanning resolution and the output resolution stated as a percentage If the output resolution is set to 720 dpi and the scanning resolution to 360 dpi then the magnification rate is 50 Moire The patterns or lines created by overlapping dots in an image This phenomenon is found when photographs or pictures ar
45. icient insufficient for the memory RAM required volume of 2 Memory is insufficient the scanned image Increase the memory data allocated the application Close all application programs other than the one used to start Plug in Module CS U Increase the memory allocated to the application program used to start Plug in Module CS U gt p 57 Click Cancel to cancel or rescan after lowering the scanning resolution or reducing the scanning area As image size is large it will take long to complete scanning Do you want to continue e You attempted to scan an image exceeding 100 MB I 1 Cannot complete scan J Memory is x d An error has occurred e Scanner or computer e Restart the computer Error Code Restart is malfunctioning If the same error code displays the PC after restarting the computer contact the nearest Canon Customer Support Help Desk Glossary Auto Tone Correction A function that uses brightness contrast and gamma value settinos to automatically analyze and adjust images Bits Bit Numbers Each dot of a 1 bit image Is assigned either black or white according to the threshold brightness value resulting in the image being reproduced in just those two colors Each dot of an 8 bit grayscale image can be assigned any one of 256 tones of gray ranging from pure white to black Each dot of a 24 bit color image can be assigned any one of 16 7 million colors sinc
46. ight mark to another position the image can be adjusted easily for optimum effect with the Auto button STEP 3 The histogram settings can be adjusted for all channels Master or for individual channels R G B The selectors are displayed to the left of the histogram graph Master R G B The Master selection is unavailable if Grayscale has been selected as the scan mode Clicking directly on this bar causes the shadow or highlight hadow Mark anado mark whichever is closest to advance to that position All of the data to the left of this mark is set EN to the shadow 0 Highlight Mark value Drag the mark I Adjustment E All of the data to the to the right or left right of this mark is set to the highlight 255 value Drag the mark Displays the current e to the right or left level at the shadow mark Click the up or down arrows in the spinbox to increase or decrease the setting or enter a number directly into the entry box 0 245 Displays the current level at the highlight mark Click the up or down arrows in the spinbox to increase or decrease the setting or enter a number directly To restore the histogram into the entry box settings click this 10 255 Reset button The Tone Adjustment To restore all settings settings can be saved to their defaults click in a file and reloaded the All Reset button for later use Black Eyedropper Button Auto Button White Eyedropper But
47. ill cause the selection frame to move without changing its shape e Placing the mouse cursor over the dotted line of the selection frame causes the cursor to change into one of four shapes 1 7 Dragging the selection frame with the mouse cursor changes its shape e Double clicking the mouse button anywhere in the preview window selects the entire image Hint e To specify small areas with precision it is convenient to expand the preview display with the Zoom In button See Zooming P 31 E You can specify a selected area of the image for enlargement with the zoom features You can use the zoom function to select an area with high precision or to select small areas for scannino Procedures to Zoom In Select the area you want to enlarge with the zoom function See Setting the Scan Area p 30 Canon plug in module CS U 4 1 Setting File Image Preferences Film Scan Mode EB 24bit Color E Output Device BI 180dpi Resolution 180 api Magnification 1002 Selection Frame Image Size 356 466 ps meme mm o sns g 506 2 095 902 kb Canon Plug in module CS LI 4 1 P Click on the Zoom In button The selected area will be displayed in expanded form If you want to enlarge the image again reduce the size of the area selected with the frame and click the Zoom In button again Canon plug in module CS U 4 1 Setting File imag
48. in 32 Zoom out 32 Zoom Reset 32 Canon Customer Support Help Desk CANON INC 30 2 Shimomaruko 3 chome Ohta ku Tokyo 146 8501 Japan CANON U S A INC Digital Home and Personal Systems Division 2995 Redhill Avenue Costa Mesa CA 92626 U S A 1 800 OK CANON http Awww ccsi canon com CANON CANADA INC 6390 Dixie Road Mississauga Ontario L5T 1P7 Canada 1 800 OK CANON http Awww canon ca CANON LATIN AMERICA INC 6505 Blue Lagoon Drive Suite 325 Miami Florida 33126 U S A CANON MEXICANA S de R L de C V Anillo Periferico Sur No 4124 Torre Zafiro II Colonia Ex Rancho de Anzaldo Piso 5 y 6 Mexico D F Tel 525 5490 2000 CANON PANAMA S A Apartado 7022 Panama 5 Rep de Panama Tel 507 279 8900 CANON CHILE S A Ave Manquehue Norte 1337 Piso 3 Casilla 187 9 Santiago Chile Tel 562 366 6600 CANON ARGENTINA S A Ave Corrientes 420 1043 Buenos Aires Argentina Tel 5411 432 59800 CANON EUROPA N V P O Box 2262 1180 EG Amstelveen The Netherlands CANON UK LTD Woodhatch Reigate Surrey RH2 8BF United Kingdom For technical support please contact Canon Helpdesk Helpdesk P O Box 431 Wallington Surrey SM6 OXU TEL 08705 143 723 FAX 08705 143 340 For sales enquiries 0121 666 6262 CANON FRANCE S A 17 quai du Pr sident Paul Doumer 92414 Courbevoie Cedex France T l 01 4199 7777 Fax 01 4199 7951 Hotline T l 01 4199 7070 l OE 060A CANON DEUTSCH
49. lect a device from the pop up menu Canon plug in module C U 4 1 Setting File Image Preferences film Output Device CRTCZ20pi Web 72dpi Resolution BIC 80dpi BJ 36 ndpi BJ z72 dpi LBP 300dpi LBP 600dpi Required Frea OCR 300dpt OCR 400dpi OCKR 600d pi FAX 200dpi File 100dpi File 15 0dpi File 30 0dpi File 400dpi File 600d pi File 120 0dpi File 240 0dpi Magnification Image Size Canon Plug in module Caution e You can set the device categories in the pop up menu in advance You can also add new devices to the pop up menu See Setting Preferences p 25 Setting the Resolution and Magnification The magnification of an image can be changed before scanning to accommodate reproductions that are larger or smaller than the original The settings can be changed in increments of 1 12 30cm ons at 200 6 15cm Scanning horizontal vertical 2x magnification 4 10cm Scanning at 50 gt i Scanning with horizontal vertical 0 5x magnification 8 20cm 3 7 5cm E W 2 5cm Chanoing the magnification setting causes the resolution display on the control panel to change correspondingly This resolution setting is referred to as the scanning resolution Output Device Resolution 720 dpi Magnification 100 Resolution OL 2 Fan Resolution WY ET 360 japi Magnification a cn Magnification Pm Image Size T um 400 600 E
50. lick a pre set value or the custom option Click the appropriate radio button to select a numerical setting After you click the Custom button you can drag the slidebar to adjust the setting or you can enter a value directly into the entry box iio qid A15 Q22 i Custom m Drag left or right to Click the up or down change the setting arrow in the spinbox to increase or decrease the value or enter a number directly into the entry box 0 1 10 0 Caner C The Tone Adjustment settings can be saved in a file and reloaded for later use To restore all the default settings click this button To restore the gamma default settings click this button Click the OK button The changes are reflected in the image currently displayed in the preview window STEP 3 Adjusting the Threshold Value When the scan mode is set to black and white the image brightness can be F adjusted The threshold value setting determines whether a halftone will be expressed as a black or a white data point The possible threshold values range between 0 and 255 Below a given threshold value all data is converted to black Likewise all data with a value above the threshold is converted to white Accordinoly higher threshold values produce darker images while lower threshold values result in brighter images Threshold Value 128 Standard Threshold Value 180 Threshold Value 70 To Set the Threshold Value When the scan m
51. m It must be started from a plug in compatible application program such as CanoScan Toolbox or Adobe Photoshop LE e The size of the Plug in Module CS U control panel will vary according to the resolution of the computer display e The size of the control panel can be adjusted with the Preview Window option in the Preferences menu p 26 Positioning Originals Place the original you intend to scan on the scanner s document glass platen Procedures Place the original on the scanner s document glass Open the cover and set the original face down on the scanner document glass with the top edge at the back of the scanner Align the original s corner with the alignment mark Alignment Mark P Close the cover carefully so the original does not shift out of position Caution e Be careful not to dirty the document glass when placing items on it e f an original has distinct horizontal or vertical lines you should try to position it on the document glass as squarely as possible to have the lines appear straight e The maximum scanable size is the area of the entire document glass e Straighten out curls or folds in originals before placing them on the document glass e To scan right to the edges of an item position it approximately 3 mm away from the edges of the document glass platen Previewing EJ The preview scan is a trial scan performed before the final
52. ng time Resolution is set too high Lower the resolution to the minimum required settings and rescan A Problem Solution e Problem Can t scan with the film adapter unit Set the film guide correctly on the document glass platen See the user guide for the film adapter unit Colors in the Preview area are strange Solution 1 The original is faded Try retouching the colors with an image editing program image editing program manual Solution 2 Color balance and brightness are incorrectly set Reset them Solution 3 The fluorescent lamp inside the scanner is not sufficiently warmed Please wait for a minute or two then perform a preview scan again Solution 4 Calibration slot on the film guide is obstructed Clear any items or e Problem Solution dust blocking the calibration slot See the user guide for the film adapter unit Entire image is whited out or blackened when the image type is set to black and white The threshold value is set too low or high Increase decrease the threshold value e Problem gt Solution 1 Solution 2 Solution 3 e Problem Solution e Problem Solution 1 Solution 2 Scanning quality is poor Resolution is too low Raise it and rescan Original is floating off the document glass platen Place the original correctly on the document glass D
53. ngapore 079906 http www canon asia com CANON MARKETING SERVICES PTE LTD No 1 Jalan Kilang Timor 3109 00 Pacific Tech Centre Singapore 159303 Tel 65 7998888 Fax 65 2736786 Hotline 65 3342726 http Awww canon com sg CANON MARKETING MALAYSIA SDN BHD Block D Peremba Square Saujana Resort Section U2 40150 Shah Alam Selangor Darul Ehsan Malaysia Tel 603 7446000 Fax 603 7446048 Helpdesk 603 7446008 9 Enquiry print amp scan canon com my http Awww canon com my CANON MARKETING THAILAND CO LTD 179 34 45 Bangkok City Tower 9th 10th Floor South Sathorn Road Thungmahamek Sathorn Bangkok 10120 Thailand Tel 662 3449999 Fax 662 3449968 http Awww canon co th CANON MARKETING PHILIPPINES INC Marvin Plaza Building 2153 Don Chino Roces Ave Makati City Metro Manila Philippines Tel 632 8126047 Fax 632 8120067 8109797 CANON INDIA PVT LTD Neela Gagan Mandi Road Mehrauli New Delhi 110030 India Tel 91 11 6806572 Fax 91 11 6807180 CANON HONGKONG CO LTD 9 F The Hong Kong Club Building 3A Chater Road Central Hong Kong TEL 852 2739 0802 FAX 852 2739 6428 CANON AUSTRALIA PTY LTD 1 Thomas Holt Drive North Ryde Sydney N S W 2113 Australia Info Line 02 9805 2864 CANON NEW ZEALAND LTD Fred Thomas Drive Takapuna P O Box 33 336 Auckland New Zealand Info Line 0900 522666 ADOBE SYSTEMS INCORPORATED http Awww adobe com ARCSOFT INC http Awww arcso
54. nly one button can be selected Caution e Changing the preview window size will cause the image previously displayed in the preview window to disappear Hint e f the Save preview image option is selected the last preview image will appear in the preview window when Plug in Module CS U is launched again after quitting once This reduces the steps required to rescan the same image repeatedly Shut off lamp time This option turns off the scanner lamp which is otherwise continually on while the power is on to save power if it remains idle for a specified lenoth of time It can be set to any interval of 4 minutes between 4 and 56 minutes the actual shut off time may vary slightly from the specified interval This setting is automatically set to 12 minutes when Plug in Module CS U is first installed Shut off lamp time setting Click the up or down arrow in the spinbox to increase or decrease the number setting or enter a number directly into the entry box Reset Default Settings Returns the preference settings and all other settings to the factory default settings The tables list the major default settings Scan Mode 24bit Color Magnification 100 Unit Pixels Basic Resolution Platen 72 dpi Basic Resolution Film 600 dpi Control Panel Position Center Image Recommended Unsharp Mask On Descreen Off Shut of Lamp Time 12minutes Film Type Color Negative Close Plug in After Scan This setting d
55. ocument glass or underside of the document cover is dirty Clean them Smudges are appearing on glossy color photo scans Photos are adhering to the document glass are causing the light to refract creating the striped patterns Shift the photo to a different position on the document glass or clean the document glass before rescanning Coloring of the preview image and the printed image is different Insufficient printer toner ink Replenish or replace the toner printer manual Color balance or gamma value setting in the printer driver doesn t match the printer Manually adjust the settings in the printer driver printer manual Error Messages Error Message Cause Response e Use the USB cable to connect the Macintosh to the scanner properly and connect the AC adapter correctly to the scanner Scanner is not connected Connect the scanner e AC adapter and USB cable not connected correctly Scanning unit is locked Release the lock switch and connect the PC to the scanner again e The scanning unit lock not released After releasing the lock temporarily disconnect the AC adapter or USB cable Reconnect it and restart Plug in Module CS U and click Preview e The scanning unit is out of order e Contact your nearest Canon Customer Support Help Desk Reduce the scan area to the minimum possible scope and lower the resolution and magnification settings for the output device command Insuff
56. ode is set to black and white click the Tone Adjustment button or pull down the Image menu and select Tone Adjustment Drag the slidebar left or right to adjust the threshold setting Click the up or down arrow to increase or decrease the entry in the text box or enter the value 0 255 directly from the keyboard After adjusting the threshold value you can save the setting to a file under a file name and load the file again whenever you want to use the setting To restore the threshold setting to its default value click this button Click the OK button The preview image will change to reflect the new settings STEP 3 Auto Tone Correction When the selected scan mode is Color you have three options for adjusting the color Recommended ColorSync or None The default setting is Recommended Recommended Reproduces the colors of the scanned item vividly on a computer display You are advised to use this mode under normal circumstances ColorSync Automatically matches the color settings of the scanner computer display and color printer Select this mode when you wish to set the appropriate color profile to view the colors of the scanned image on the computer display as closely matched to the original image as possible None Scans without color correction Select this mode when you wish to adjust the colors yourself with the color correction features of Plug in Module CS U or another application progr
57. of focus The function is on when a check mark appears beside it and off when there is none The default value is On Caution e This setting is not available for the black and white scanning mode e f Plug in Module CS U is started within an application that hides the Plug in Module CS U control panel the previous setting will be maintained Operating Procedures b Open the Image menu and select Unsharp Mask Recommended ColorSvnc None Tone adjustment Descreen v Unsharp Mask High speed Scan Mode A check mark will appear beside the Unsharp Mask option in the menu when this function is set to On To set it to Off reselect it The check mark will disappear Hint e Disable the Unsharp Mask function if the moir effect is still too strong even when the Descreen option is on e When the Unsharp Mask is on it may take longer to scan STEP 3 Descreen Select this option if you want Plug in Module CS U to conduct moir reduction to improve the overall image quality Moir are dot patterns that interfere with processing images for professional use and are usually caused by poor dithering resulting from scanning images from newspapers books magazines etc Caution e When you select Film in the Preferences menu the Descreen function is not available e The Descreen function cannot be switched on for scanning resolutions higher than 601 dpi e The previous setting is enabled for th
58. ons Step 1 presents the essential preparations for scanning The following procedures are explained on the indicated pages Displaying the Plug in Module CS U Control Panel v E Positioning Originals v Previewing v Selecting the Output Device Setting the Resolution and Magnification E Setting the Scan Mode v Verifying the Image Before Scanning Rotating the Image E Setting Preferences p gt p p gt p gt p p gt p 14 16 17 18 21 23 24 25 Displaying the Plug in Module CS U Control Panel The Plug in Module CS U control panel is used to perform scans Pluo in Module CS U can be opened trom CanoScan Toolbox or Adobe Photoshop LE and other plug in compatible application programs To quit Plug in Module CS U click on the close box at the top left of the control panel Adjusts the settinos for the scannino job such as the scan mode output device resolution and magnification Close Box Quits Plug in Module CS U RGB Values Menu Bar Displays the R G and B values at the Click on any menu item to display current cursor position pre adjusted more options in a pull down menu value post adjusted value ECO O I EE Canonphug in module SU setting File Image Preferences Film R 255 255 D 2538 255 B 233 255 E Scan Mode EI 24bit Color Output Device CRT 72udpi ss Resolution SO z2 lai Magnification 100 F z
59. ontrast p 47 e Color Balance p 49 Gamma Value p 50 e Threshold Value p 52 STEP gt Auto Tone ColorSync p 53 Unsharp Mask p 54 Scan 23 p 29 e Descreen p 55 e Set the Scan Area p 30 High Speed Scan Mode p 56 e Zoom p 31 m e Scan p 33 If the current brightness Save Scanned Images p 34 and color pose no problem there is no need to adjust e Scan Film p 35 these settings Plug in Module CS U Special Features See the Results of Adjustments Immediately Dynamic Preview Once in preview mode the results of adjustments to scan mode settinos and colors are promptly reflected in the preview image Highly detailed adjustments can be performed easily because you can see the results of your changes as they are executed e ColorSync Ver 2 0 Compatible for Auto Tone Correction Compatible with the Mac OS 8 5 ColorSync Ver 2 0 color management software This function automatically matches the color profiles of various devices such as scanners color displays and color printers for optimal color reproduction Browser Function Permits Confirmation of the Real Image Before Scanning The Browser function lets you check the image to be scanned in detail before commencing the scan This function presents a much higher quality image than the preview function Histogram Function Realizes Beautiful Contrast Simple operation allows you to achieve beautiful contrast with half ton
60. or or grayscale image mode Threshold Value The dividing value at which a pixel is determined to be either black or white when the image is reproduced as a black and white image The higher the threshold the darker the image The lower the threshold the brighter the Image Tone Curve A function used to adjust image brightness The tone curve or gamma curve is a graphic representation of the relationship of the input from the scanner to the output to the monitor or printer Unsharp Mask A function that sharpens image outlines Makes an image appear naturally sharper without changing the brightness contrast or color balance White Eyedropper Tool Tool used to the select the brightest portion of an image in the preview area Used with the Histogram function to adjust image brightness When this tool is clicked on the image all areas that are brighter are set to pure white Index A Alignment mark 16 Application Compatible 75 Stand alone 15 Aspect ratio 25 Auto Tone Adjustment button 7 40 Black and White 21 Black Eyedropper button 43 Brightness 47 Brightness Contrast tab 47 Browser button 7 11 23 C Calibration 17 CanoScan Setup Utility CD ROM 10 Close box 7 14 Color 67 Color balance 49 66 Color balance tab 49 Color channel 66 ColorSync 6 9 53 67 Contrast 43 67 Control panel 14 D Descreen 55 Disk space Available 27 Required 27 Dot 67 DPI 67 Dynamic preview 9 17 F File
61. pi HEU db Magnification io Az Image Size 1 386 1 890 px Required Free 77 20050 mb Canon Plug in module CS U 4 1 Move the pointer in the selection frame inside the preview window e The mouse cursor will change to a sign shape Move the Selection Frame to the desired position with the mouse cursor e Moving the mouse will move the Selection Frame Click the mouse button when the selection frame is in the correct position e The image will be scanned and the browser image displayed in the middle of the monitor Once you have examined the browser image click the mouse button again to close the browser window e The browser window will close e t does not matter where the mouse cursor is positioned to close the browser window Rotating the Image You can rotate the image in the preview window clockwise to the right or counterclockwise to the left in increments of 90 or 180 degrees To rotate the image click the appropriate button Caution e f you rotate the image in the preview area the scanned image will also rotate Operating Procedures b Use these buttons to rotate the image To rotate the image clockwise 90 degrees To rotate the image clockwise 180 degrees To rotate the image counterclockwise 90 degrees Setting Preferences The Preference settings determine how Plug in Module CS EZER U operates for the following options output device printer
62. se a paper size in the Mode option The selection frame will Paper size Portrait Paper size Landscape have a fixed aspect ratio height to width ratio when it is Letter Custom resized in the preview window Unit Specifies the units that define the size of the scanned image Unit Settings Dialog Unit Settings Image Size O Es in Required FFPee 7 7 Z 2 095 9 T att 2 Oss 000 2 095 9 E P Canon Plug in module CS U 4 1 Unit Pixel px Inches in Q Millimeters mm Q Centimeters cm C The units displayed in this section of the control panel will change Preview Window You can size the preview window and set its resolution Enter a large value for a large preview window size You can also use this feature to set the auto preview and preview cache options Preview Window Settings Dialog Preview Window Settings Window size Allows you to enter values Puent setings MEN setings and change settings for the Resolution m i eee re preview window options Memory for execution about he KB KB The maximum values are determined by the type of monitor you are using Memory required to save the file 154 ke Preview setting Automatically perform a preview Save preview image Click the appropriate radio button for the function you want to switch on Automatically perform a preview Save preview image and None O
63. so click the Auto Tone Adjustment button so the histogram highlights and shadows are adjusted for you automatically to the optimum settings Caution e Adjustments cannot be made when the ColorSync option is selected p 49 Image Menu Canon plug in module C5 U4 2 C 41 Setting File yeni Preferences Film R 285 285 0255 255 B 255 255 Bb 255 255 B12552255 Recommended scan Moda Colorsync None Displays the RGB values at the current cursor position Pre adjusted value post adjusted value Output Devicg Tone adjustment Descreen dpi X Unsharp Mask High speed Scan Made i Image Size 540 822 px Fesalutio Magnificatio Required Frea mb Auto Tone STO r Adjustment Button Tone Aqjustment Button Tone Adjustment Dialog The Tone Adjustment dialog contains tabs for the following features histogram tone curve brightness contrast color balance and gamma If black and white has been selected as the scan mode the threshold feature also becomes available on the histogram tab The settings selected in the Tone Adjustment dialog are also reflected in the next preview image To scan a new item ensure that you click the All Reset button to restore all of the settings to their default values Tome Adjustment Click the appropriate tab D Emo a ea EEE B Reset Here is the Tone Adjustment dialog with all Here is the Tone Adjustment di
64. solution gt p 19 or scan area 3 p 30 until the required memory is lower The Insufficient Memory error message appears when scanning Solution 1 Select the smallest possible area and rescan Solution 2 Lower the resolution and magnification settings for the output device to the lowest possible values gt p 19 Solution 3 Rescan after closing all the application programs other than the one used to start Plug in Module CS U Solution 4 Rescan after you have restarted the application program used to start Plug in Module CS U Solution 5 Quit the application program used to start Plug in Module CS U and increase the memory allocated to it Click the application program icon once Then open the File menu choose Get Info and choose Memory from the submenu Increase the memory in the Preferred Size box to at least 16 000 K Solution 6 Increase the amount of RAM as required e Problem Solution The Image menu ColorSync option cannot be used in Plug in Module CS U ColorSync is not recognized after Mac OS upgraded to Version 9 after Plug in Module CS U was installed onto Mac OS 8 6 Reinstall Plug in Module CS U gt p 6 e Problem gt Solution e Problem gt Solution No free disk space message displays when you start a scan Since there is insufficient free space on your hard drive clear non essential files to create more space Scanning is taking a lo
65. t Hardware e Power Macintosh iMac PowerBook or iBook with built in USB ports performance on Macintosh compatibles is not guaranteed Main Memory e 32 MB or more 64 MB or more recommended Application Software e CanoScan Toolbox e Adobe Photoshop LE e Other plug in compatible application programs Display e 32 000 colors or more System Software e Mac OS 8 5 9 Caution e The ColorSync Profiles file is installed along with Plug in Module CS U ColorSync Ver 2 0 or higher is required to use these profiles with the automatic color matching system p 49 Control Panel Features When you need more information about a control panel button or menu refer to the illustration below and go to the referenced page number for more details e The illustration may differ slightly from the version of Plug in Module CS U provided in your package Image Preferences v Recommended Output Device e Colorsyne a Aspect Ratio gt pp 25 28 EU Unit Tone adjustment p Preview Window Descreen Shut off lamp time X Unsharp Mask E Resets Default Settings Film Settings High speed Scan Mode gt p 56 Hec pd UR sr SEL Available whin Film is Setting File di Dd selected in the Preferences ilm Load menu p 35 save Close Box RGB values p 14 p 14 Scan Mode gt p 21 Gaon pugi module 6 044 3 Output Device etting File Image Preferences
66. t to adjust the brightness setting You can also click the up or down arrow in the spinbox to raise or lower its value or enter a number directly into the entry box 127 127 Drag the slidebar left or right to adjust the Contrast setting The Tone Adjustment settings can be saved in a file and reloaded for later use To restore all the default settings click this button To restore the brightness contrast default settings click this button Click the OK button The settings will be reflected in the image currently displayed in the preview window STEP 3 Adjusting the Color Balance You can enhance color matching by adjusting the color balance of one or all of the RA three primary colors red green and blue RGB Use this feature to adjust the color balance when you see an over abundance of a color in a scanned image Hint e You cannot use this feature with the black and white or grayscale scan modes or with the color scan modes when ColorSync is selected e There may be wide differences in the contrast and hue of the display image and printout depending on the monitor and printer settings You may have to adjust the settings and execute some test prints to attain the best match between what you see in the image on the display and in the printout gt Operating Procedure p Click the color balance tab in the Tone Adjustment dialog Adjust the color balance for
67. ta widely distributed between shadows and highlights Entire Image STEP 3 How to Adjust Histograms To change the contrast in an image the distribution of data between shadows and highlights can be adjusted by dragging the shadow and highlight marks at the bottom of the histogram All of the data lying to the outside left of the shadow mark is changed to a zero value and all of the data lying to the outside right of the highlight mark is changed to a 255 value The examples below show adjustments to improve the contrast Use the Auto setting to adjust the histogram for most jobs p 41 The graphs below show images adjusted with the Auto setting IMAGE Image with a bias IMAGE Image with a bias IMAGE mage with well toward highlights toward shadow 3 distributed data Move the shadow mark Move the highlight mark Move both the shadow and toward the highlight end toward the shadow end highlight marks inward To Adjust a Histogram b P P Specify the area of the image the entire area to be scanned for which a histogram will be generated See Setting the Scan Area p 30 The histogram will not display correctly if an extremely small area is selected To select small areas first expand the display with the Zoom In button See Zooming p 31 Click the histogram tab in the Tone Adjustment dialog to display the histogram options Click the Auto button Although you can freely move the shadow mark and highl
68. tandard and Hard Soft Compensates for high contrast dirt and scratches At this setting it may not be possible to restore areas under large flecks of dirt or scratches Standard This setting is recommended for most purposes Hard Compensates for low contrast dirt and scratches Although its may restore areas under large flecks of dirt or scratches it may leave artifacts after processing amp Caution e This function cannot be used with black and white film It may also fail to have any effect on KODACHROME film e Areas under dirt and scratches may not be removed if the selected scan area is too small e There are occasions when areas under dirt or scratches on the top or bottom edges cannot be removed e f the edge of the film guide is included in the scan area the areas under dirt or scratches at the boundaries of the scan area may not be removed e The Remove Dust and Scratches function will not work at resolutions above 2400 dpi Please reset the output resolution at or within 25 and 2400 dpi In addition lower the magnification so that the scanning resolution remains at 2400 dpi or less If for example the output resolu tion is set to 1200 dpi and the magnification to 40096 the resulting scanning resolution is 4800 dpi or four times the output resolution 1200 dpi x 400 4800 dpi Operating Procedures Open the Image menu and select Hard Standard or Soft from the Remove Dust and Scratches submenu
69. ton Click the Black Eyedropper Automatically sets Click the White Eyedropper and click the position in the the highlight and and click the position in the preview image you want to shadow settings for preview image you want to set to black 0 optimum effects set to white 255 P Click on the OK button The preview image will change according to the values specified with the histogram i Hint e The histogram dialog can also be displayed by selecting Tone Adjustment from the Image menu Tone Curve Settings OUTPUT You can edit the tone curve directly by changing the shape of the line on the graph When you change the setting by manipulating the curve you can perform fine adjustments in the brightness of only the shadows only the highlights or both the shadows and highlights Hint 2 e You cannot use this feature with the black and white or color scan modes when ColorSync is selected Manipulating the Graph The following examples show you how to manipulate the graph to change the settings When you test these settings yourself you can see the changes immediately reflected in the preview window or the browser to achieve many interesting effects Drag the mid tones of the input side scanned image into the highlights of the Unadjusted Curve output side displayed image OUTPUT 7 If you want to brighten the light areas Reverse the starting and end points of the line to invert s
70. u are scanning full color images such as photographs or illustrations e f you are using an OCR optical character reader program in Black and White mode you are recommended to select a resolution higher than 300 dpi Appendices Mi Troubleshooting gt p 61 E Error Messages p 65 Mi Glossary gt p 66 El index gt p 71 ESSI Canon Customer Support Help Desk gt p 73 Troubleshooting Please refer to the following information if you encounter a problem using Plug in Module CS U For further details refer to the Troubleshooting item on the CD ROM provided with your scanner If your problem lies outside the solutions provided below consult the retail outlet from which you purchased the software or the closest Canon Customer Support Help Desk ES Hint e Before you call for assistance read Quick Start Guide or Troubleshooting e When you contact one of the help desks listed you will be asked what kind of computer is connected with the scanner Before you call make sure you have prepared the information required on the system information page in the Quick Start Guide e Problem Solution e Problem Solution e Problem The Can t use the driver required for a USB device Search the Internet for a driver dialog displays on a system running Mac OS 9 only applicable to Mac OS 9 Scanner software has not been inst

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung DH 410  télécharger le mode d`emploi  Mode d`emploi complet Fast Splint Matrix  Power Acoustik CRYPT CPT4-1200 User's Manual  warning  RN-BGS3C-W6GSL・R他  山岳トイレ技術分野 実証試験結果報告書 有限会社山城器材 分割版1  軽口・コンパクトながら吸込仕責事 70W*`でパワフルにゴミを吸い取り  Georges Perec : pour être, besoin d`étai / Georges Perec, W  GPSMAP® 620 GPSMAP 640  

Copyright © All rights reserved.
Failed to retrieve file