1. Divar Installation Manual Operating instructions EN 3 8 Zoom To zoom in on a camera picture 1 Press the ALT key i gt The ALT indicator lights 2 Press the zoom key E gt The zoom indicator lights gt The picture is enlarged by a factor of 2 3 Use the arrow keys to select the area of the picture to be displayed 4 Press the zoom key again to zoom in further gt The picture is enlarged by a factor of 4 5 Use the arrow keys to select the area of the picture you want to see 6 Press the zoom key again to return to a full picture and leave the zoom mode gt The zoom indicator no longer lights 7 Press the ALT key to return the keys to normal operation gt The ALT indicator no longer lights Bosch Security Systems Divar Installation Manual Operating instructions Live playback and search modes Live mode The live mode is the normal operating mode of the unit where you watch live pictures from the cameras From the live mode you can switch to the search mode the playback mode or to the system menu Access to search and playback functions may require a password Discuss this with your administrator Press the search key to switch to the search mode The search menu opens To enter the playback mode use one of the following keys Press the rewind key EX to start reverse playback of recordings for the displayed cameras Press the forward key EA to start playback from on
2. Enter the same begin and end address to specify a single IP address Enter different begin and end addresses to specify an IP address range Use the up down arrow keys to move to an IP entry Press the select key to edit the entries Press F1 to set the default values 000 000 000 000 to 255 255 255 255 List of Users Enter a name up to 16 characters long for each user Enter a password up to 12 digits long e Set User Rights to Live to restrict viewing rights to live video only e Select the cameras in the Camera Lock Out submenu that are not accessible for the user Set the camera sequence list and dwell time from 3 to 59 seconds for the remote viewer All connected cameras are listed by default Set Camera Control to allow control of controllable cameras remotely gt gt gt Expand system e When you have multiple units linked give each unit a unique identification number from 1 to 30 Enter a first camera number from 1 to 999 to offset the camera numbers for the different Divars Only default camera identification numbers Camera 1 Camera 2 etc are offset Bosch Security Systems Divar Installation Manual Menu system gt gt gt COM port The COM port is an RS232 serial port used mainly for connecting a PC or an alarm panel to the unit Most parameters are fixed Select the appropriate baud rate gt gt gt ATM POS setup requires bridge and license The list of all
3. Use the escape key to go back or to switch off the menu Bosch Security Systems Divar Installation Manual Quick install EN 2 4 QUICK INSTALL MENU gt QUICK INSTALL LANGUAGE ENGLISH TIME ZONE GMT 01 00 WEST EUROPE TIME FORMAT 24 HOUR TIME 19 45 00 DATE FORMAT YYYY MM DD DATE 2002 06 20 1922535417552 LO 211212215 al 5 Uy alts ACTIVE CAMS ALARM MONITOR MON A ONLY RECORDING SETTINGS gt NETWORK SETTINGS gt SAVE amp EXIT gt CANCEL gt gt LANGUAGE e Select the language for the menu from the list gt gt TIME ZONE Select a time zone from the list gt gt TIME FORMAT e Select either a 12 or a 24 hour clock format gt gt TIME Fill in the actual time gt gt DATE FORMAT Select from three date formats which show either the month MM the day DD or the year YYYY first gt gt DATE Fill in the actual date gt gt ACTIVE CAMS e Select the cameras you wish to activate Only activated cameras are configured after exiting the Quick Install menu Press the camera keys to select or deselect a camera A check mark means selected gt gt ALARM MONITOR Select the monitor on which input alarm messages are displayed gt gt RECORDING SETTINGS Opens recording settings submenu to fill in the basic recording settings for the day and weekend night profi
4. 00 ccc cece eee 6 4 Introducing the main WiINdOW 1 cee 6 5 Overview ib tten ae rs ee See en Be 6 5 History DUON race te a 6 5 Settings button 0 nennen nennen 6 5 Semice DUTTON esses dos Settee He ein 6 6 Help button un He rea an ee inne 6 6 Logout button oooocccoccccocccno nennen nn nn 6 6 Using the control buttons pr erines eee eee 6 6 Menu default values i ask cave ase ee eee ee hee 7 1 Technical specifications oooooooomoo 8 1 Electrical Miu A Rn 8 2 Mechanical ne ron eee ei 8 3 Environmental cel sen fas Dt aa a di en chic 8 3 Accessories Optional oooooooocooocnrn een nenn 8 3 Bosch Security Systems Divar Installation Manual EN iv SAFETY PRECAUTIONS AN RISK OF ELECTRIC MA SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT OPEN COVERS NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL This label may appear on the bottom of the unit due to space limitations A A The lightning flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance servicing instructions in the li
5. 8 4 Bosch Security Systems Bosch Sicherheitssysteme GmbH Ludwig B lkow Allee 85521 Ottobrunn Germany www bosch sicherheitssysteme de 2005 Bosch Security Systems B V Subject to change Printed in Portugal Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands www boschsecuritysystems com BOSCH
6. List of IP addresses 0 0 0 0 255 255 255 255 List of users User name ADMINISTRATOR USER2 6 User rights Playback User password No password Expand system DVR ID 1 First camera number 1 Com port Connect to CCL Baudrate 9600 Parity None Bits 8 Stopbits 1 RTS CTS On Input and Output contacts Inputs N O Outputs N O Bosch Security Systems Divar Installation Manual Menu default values Level 1 Level 2 Profiles Level 3 Level 4 EN 7 7 Level 5 Default value Profile manager Camera pre position on profile change Camera pre position None System behavior Event handling Select profile 1 Inputs enable Enabled for connected cameras Inputs alarm Enabled for connected cameras Motion enable Disable all Motion alarm Disable all Video loss enable Enabled for connected cameras Auto acknowledge alarms Yes Output handling Select profile 1 Relay enable Relays 1 and 2 enabled Beeper Enable Recording setup Normal List all cameras quality IPS Medium 11PS Input Cameras not in alarm IPS No change Recording duration 30 seconds Bosch Security Systems Divar Installation Manual Menu default values EN 7 8 Level 1 L
7. Set to None so that the search is not restricted by events Set to Smart Motion Seach to search for motion in a designated area of a particular camera picture Set to ATM POS to search for transactions based on the text string you enter Specify the cameras to search for The selected cameras are shown at the bottom of the menu with a check mark Press a camera key to change the selection If Smart Motion Seach is selected only a single camera can be selected Select Forward to search from start time to end time or Backward to search from end time to start time Bosch Security Systems Divar Installation Manual Operating instructions EN 3 11 Fill in a time and date from which to start the search e Fill in an end time and date to limit the time span of the search PLAYBACK SEARCH If ATM POS is selected fill in the text string 16 characters maximum 2EARCHIRESULTS you wish to search for This text string is case insensitive CAMERA 1 MOTION 2002 03 14 15 00 17 Select Start Search or press F2 to initiate the search procedure If Smart Motion Search is selected you must set the motion sensitivity and select an area before the search procedure is initiated Use the arrow keys to adjust the Motion Sensitivity The higher the value the higher the sensitivity e Select Motion Area to define the picture area that is to be examined for motion Use the arrow keys to move around the grid Press F1 to insert a
8. Tool when asked to complete the installation EN 6 2 Starting the Configuration Tool Starting the Configuration Tool depends on how you are connected to the unit e via a serial RS232 connection e via a network or e offline Serial connection If your PC is connected directly to the unit via the serial RS232 connection double click the Configuration Tool icon on your desktop window to start the program Select the Serial connection entry from the DVR list Network connection To start the Configuration Tool without using the Control Center double click the Configuration Tool icon on your desktop window to start the program Alternatively select the Divar Configuration Tool program via the Start button on the task bar and the Programs menu item Follow the login procedure To start the Configuration Tool via the Control Center click the Config button in the Control Center window You must first be logged into the Control Center as an administrator to open the Configuration Tool in this way Offline configuration If you choose to log in with an offline configuration you should select the Divar version model the video standard and the cameras that are connected Bosch Security Systems Divar Installation Manual Using the Configuration Tool How to Log in When you start the Configuration Tool as a stand alone application via a network the Login window appears Click Cancel to discontinue login
9. 5 6 Stop recording ss aa wann a an Sane sys 5 6 Storage setup A a en ne 5 6 Delete Video 2 eect eee teen tenet ee eee eee 5 6 Erase DISK A eds 5 6 Limel Date gt sc Sr a a a Fea tend A ee ee a 5 7 DINO ONZA FE i tal 5 7 View Settings gt ee eens 5 7 Camera setup ru un Soke ee ee ne nn 5 7 Camera controllable 0 0 nennen nenn 5 8 Bilinx Cameras 26 eee eee eee teen eee 5 8 SEA ENCES essen il ee eit ae ed ode ee 5 8 Configure Monitors 1 0 0 0 eee 5 8 System Settings gt a iega e i g a a AE AA Ra 5 9 Recording Setup 1 ccc ees 5 9 Playback Setup 0 0 5 10 Event Setup since ene clk Gre ene E une 5 10 History Log Setup oooooocccccccocococncccc ee 5 11 Local Passwords a sees age aha Rete wie et wrens god abi 5 12 Gonnectivity estate deg ait oe en ae a ede ee a 5 12 MITE ee erlernen 5 13 Input and output contacts 2 220 nennen rennen nn 5 13 Profiles a a de a at aa 5 13 Calendar setup acs o e aaa seen nennen nennen n nn 5 13 Profile override oocoocooconccrcoonconar rn nn 5 14 Profile manager 0 cece 5 14 System behavior 0 ee 5 14 Using the Configuration Tool 6 1 Getting Started a na a Rae dara 6 2 System requirements 00 eee 6 2 Installing the Configuration Tool 0 0 6 cee eee 6 2 Starting the Configuration Tool 0 0 cee eee 6 2 Fow O LOG IM sews sie ee near af ape Macao dk or fan af 6 3 Menu structure differences
10. ATM POS bridges connected to the unit shows the IP address and the connection status Use the arrow keys to move to a bridge and select it to open a terminal configuration menu for that bridge Terminal Setup Edit the IP address of the selected bridge if required The names of all terminals connected to the bridge are shown with their associated camera Only data from terminals with an assigned camera is stored Use the arrow keys to move to a terminal and select it to open a list of available cameras Select a camera to assign it to the terminal A camera cannot be assigned to two terminals A terminal can only have a single camera assigned to it Press Fl to remove all camera assignments gt gt LICENSES Fill in the key of any additional licenses you purchase exactly as supplied The MAC address and a description of the installed licenses are shown at the bottom of the menu screen gt gt INPUT AND OUTPUT CONTACTS The contacts of the input and output relays default to normally open N O e Place a check mark in the box under a specific relay to set its contacts to normally closed N C e Press a camera key to place or remove a check mark EN 5 13 PROFILES gt Six different profiles can be stored These profiles can be activated by an input switch or by a date or time The profiles contain configuration settings for recording data handling events and restricting access You can define a c
11. LAN RJ 45 Ethernet socket The standard RJ 45 Ethernet socket is used to connect the unit directly to a PC SignallName Pin no Description or to a network The Ethernet is also used to connect to an ATM POS bridge LAN_TX 1 Ethernet transmit line plus unit To connect directly to a network hub use a straight through network cable LAN_TX 2 Ethernet transmit line minus To connect directly to a PC use the supplied cross over network cable Consult LAN_RX 3 Ethernet Receive line plus with your local IT personnel for the specific type of cable needed The cable N C 4 cion length from node to node is limited to 100 feet 30 5 meters maximum length E and 6 feet 1 8 meters minimum length N C No Connection LAN_RX 6 Ethernet receive line minus Network configuration N C 7 No Connection The Divar is delivered with the DHCP function switched on so IP addresses are N C 8 No Connection assigned automatically if the network server uses DHCP Refer to the System settings Connectivity Network setup menu Specifications Connection 10 100 BaseT IEEE 802 3 ETHERNET Panel view Differential signal voltage 2 8V max inputs have transient overvoltage protection Port details IEEE 802 3 802 3u 100Base TX 10Base T physical layer Auto Negotiation 10 100 Full Half Duplex Cable length 100 Meters 100 Ohm unshielded twisted pair cable category 3 4 5 100 Meters 150 Ohm shielded twisted pair cable Impedance In built compensa
12. List To remove a video segment from the list select it with the arrow keys and press F2 Select Start Archiving to write the video segments to disk If the total size is greater than the disk capacity then only the first segments that fit are archived Those segments that are not archived remain in the list so that they can be archived to a new disk EN 5 5 Add to Archive List e Fill in a begin and end date and time for the video segment you wish to archive Select Add to Archive List or press F2 to place it in the list All recorded cameras in the time span are selected gt gt gt Finalize e Set Finalize to Yes if the disk is to be finalized after archiving e Ifa disk is not finalized it can be used for multiple sessions If finalized older CD players can read it but new sessions cannot be added anymore gt gt PROTECTED RECORDINGS Move to a protected recording in the list and press the select key to play it back Press the escape key to stop playback and return to the list Auto protected recordings are indicated by a after the entry in the list To remove the protection of a recording move to it in the list and press F2 You must fill in a password if configured and confirm before the recording is unprotected Select Add to Archive List or press F1 to place a protected recoding in the archive list Recordings to be archived are indicated by an A Bosch Security Systems Divar
13. Select Motion Area to define the picture area where motion is detected Use the arrow keys to move around the grid Press F1 to insert a motion detection area and use the arrow keys to enlarge it Press Fl again to save the area Press the escape key to cancel and return to grid square selection e Press the select key to leave the grid F2 clears all motion detection areas gt gt gt Video loss Setup e Select the monitor on which the camera with the video loss is displayed e Select the number of the output relay that is activated when video loss occurs Enable the beeper to activate it when any video loss occurs gt gt HISTORY LOG SETUP Select Yes for those events that you want to log in the history file Bosch Security Systems Divar Installation Manual Menu system EN 5 12 The entire history list is erased if you select the Clear History item Date time changes of stored video are always logged and cannot be disabled or cleared gt gt LOCAL PASSWORDS Set or change the password that allows access to playback functions Set or change the password that allows access to the configuration functions Use the camera keys 1 to 9 on the front of the unit to enter a four digit password in the dialog box that appears Enter the same password again to have it verified Press F2 to remove password protection gt gt CONNECTIVITY The Connectivity menu gives access to settings that control the behavior
14. and exit the application Account User name ADMINISTRATOR Password ld Save login information When the Configuration Tool application is started for the first time the Divar list is empty You must first add a Divar to the list To add a Divar to the list or to modify a Divar entry click Edit gt gt see following paragraph To modify the Divar list The Edit Divar list window allows you to add Divars to the list or delete Divars from the list EN 6 3 Edit Divar list is _AAPM AA DIVAR 01 Details A IP address Name To automatically detect all enabled Divars on the network 1 Click Detect gt To detect a Divar Discovery must be enabled on that Divar 2 Select a Divar and click OK to add the selected Divar to the list To add a Divar to the list 1 Click Add 2 Enter the IP address or nickname of the new Divar gt The IP address to be filled in is set in the System settings Connectivity Network setup menu of the Divar itself 3 Type a name in the Name box or retrieve it from the Divar by checking the Retrieve from Divar box 4 Click Add To delete a Divar from the list 1 In the list select the Divar you wish to delete 2 Click Delete gt The selected Divar is removed from the list Bosch Security Systems Divar Installation Manual Using the Configuration Tool Login When you start the Configuration tool application th
15. at which the video segment starts is shown Press the select key to continue playing the video you wish to protect or archive During playback press the pause key MI for longer than one second again to mark the end of the video segment gt A dialog window appears gt The date and time of the beginning and end markers of the video segment is shown Select Protect to protect the marked video from deletion Select Archive to write the marked video segment to a re writable disk Select Protect amp Archive to do both The software required to play a video segment on a PC the Archive Player is copied to the disk when a local archive is made To ensure that this software is present in the Divar use the supplied CD ROM to load the latest version of the Archive Player into the Divar Search mode Press the search key to open the search menu Use the search menu to search for stored video recordings PLAYBACK SEARCH gt gt SEARCH EVENT FILTER ALARM MOTION CAMERA ALL START TIME 2002 03 14 13 00 END TIME 2002 03 14 14 00 SEARCH DIRECTION FORWARD START SEARCH gt DISK CONTENTS EARLIEST TIME 2002 03 14 14 00 LATEST TIME 2002 06 19 20 23 FILTER VIM MIM v Y viv viv VIM MM YM E I aa eee Ole imme Orme nee SEARCH CRITERIA Set the Event filter to search for only alarm events only motion events or both
16. controllable cameras can be set up for a profile change Enter the pre position PP00 to PP99 that each camera should adopt when the profile is activated Set to None for no change gt gt SYSTEM BEHAVIOR Use the System Behavior menu to configure the event handling the recording setup and the access restrictions for each of the six profiles Profile settings can be copied from one profile to another in the Copy System Behavior submenu gt gt gt Event handling e Select the profile for which you wish to configure the event handling e Move to the line that you wish to change Press the camera keys to select an input or camera Press the select key to enable or disable the selection A check mark means enabled Enabled selections act as triggers If alarm is checked the selection acts as an alarm Bosch Security Systems Divar Installation Manual Menu system gt gt gt Output handling Select the profile for which you wish to configure the output handling Select the number of the output relays to be activated when an enabled event in the selected profile is activated Enable the beeper to activate it when an enabled event in the selected profile is activated gt gt gt Recording setup Recording behavior for each of the six profiles is specified in three submenus The Normal submenu is for a normal situation without alarms or motion events The Input submenu is for input changes The Motion su
17. diagnostic messages and to access the firmware update function This function is only available if you are connected to the unit via a serial connection and is password protected Help button Click the Help button at any time to get help A pop up help window appears Logout button To return to the Control Center application or to log on to different unit click the Logout button Using the control buttons The right side of the main window has several buttons that allow you to perform common tasks quickly Import Export All settings that you set in the Configuration Tool can be saved in a file that is stored on the PC disk You can save as many of these files as you like just give them different names The settings in these files can be loaded back into the Configuration Tool either completely or in subgroups Although these files are stored as text files and can be viewed with a text viewer do not change or edit them as this makes them unusable Import 1 Click the import button to open a settings file 2 In the dialog box select the location and name of the file you want to open 3 Select the groups of settings you want to load and click OK 4 The selected settings are downloaded to the unit immediately Export 1 Click the export button ml to save the current settings in a PC file 2 In the dialog box select the location and enter a name for the file you want to save 3 Select the gr
18. disk set or is empty SCSI mismatch change ID to X where X is the expected SCSI ID and the SCSI ID needs to be changed Not found if the disk is not connected Unused if a valid disk is found which is not used disabled EN 5 6 gt gt DELETE VIDEO Delete recorded video by filling in an end date and time and selecting delete video All non protected recordings made before the specified date and time are deleted You must confirm the deletion Protected recordings are not deleted gt gt ERASE DISK Deletes all recorded video on the disk You must confirm the deletion Bosch Security Systems Divar Installation Manual Menu system TIME DATE gt TIME DATE TIME ZONE GMT 01 00 WEST EUROPE TIME FORMAT 24 HOUR TIME 14 00 17 DATE FORMAT YYYY MM DD DATE 2002 06 19 SYNCHRONIZE gt DAYLIGHT SAVING YES START DATE TIME LAST SUN MAR 02 00 END DATE TIME LAST SUN SEP 03 00 OFFSET 01 00 Select a time zone from the list Daylight saving time is adjusted accordingly Fill in the actual time and date e Select either a 12 hour or a 24 hour clock format Select from three date formats which show either the month MM the day DD or the year YYYY first Set Daylight Saving to Yes to enable it Fill in the day month and time of both change overs and the offset if it differs from the information associated with your time zone gt gt SYNCHRONIZE Use the Synchronize functi
19. list 1 Click the save button XA to save the current settings in a PC file 2 In the Save dialog box enter a file name and location 3 Click OK to save The information is saved in a text file Clear Click the clear button to set all settings on the active page to their default values Bosch Security Systems Divar Installation Manual Using the Configuration Tool EN 6 8 Bosch Security Systems Divar Installation Manual Menu default values EN 7 1 CHAPTER 7 Menu default values The table on the following pages lists the items of the menu system of the unit with default values The righthand column of the table gives the default values of these menu items These values are restored when the Factory defaults item of the System settings menu is selected Bosch Security Systems Divar Installation Manual Menu default values EN 7 2 Level 1 Level 2 Level 3 Level 4 Level 5 Default value History Show alarms Yes Show motions Yes Show network Yes connectivity Show errors Yes Time Date Time zone GMT 01 00 Western Europe PAL GMT 06 00 Eastern time NTSC Time format 24 hour PAL 12 hour NTSC Date format YYYY MM DD Synchronize Use timer server No IP address 0 0 0 0 Daylight saving Yes View Settings Camera setup Camera name Select input 01 16 Title CAMERA 1 CAMERA 16 Camera lock out Enter password o
20. motion detection area Use the arrow keys to enlarge it e Press Fl again to save the area Press the escape key to cancel and return to grid square selection e Press the select key to leave the grid F2 clears all motion detection areas Select Start Search or press F2 to initiate the search procedure e Press the escape key E to exit the search mode and return to the previous mode gt gt SEARCH RESULTS e The recording fitting the filter and closest to the selected date and time is shown first Use the up down arrow keys to move through a long list The selected recording is shown e Press the select key for a full screen playback of the selected recording Press the search key during playback to return to the list Press the escape key E to return to the filter menu Bosch Security Systems Divar Installation Manual Operating instructions Triggers and alarms Various types of events can change the way the unit works These events can be e An alarm input signal applied to the unit e Motion detection in a camera signal e A loss of video from one of the cameras e An internal alert from the unit itself The way the unit reacts to events depends on how it has been programmed An event can cause either a trigger or an alarm A trigger can change the way the unit works but does not require a response from the user An alarm can also change the way the unit works but in addition it usually activate
21. of the unit with respect to all external devices or a network It also gives access to settings for connecting multiple units to each other and for connecting computers via the communications port gt gt gt Keyboard access restrictions Four external keyboards can be connected to the unit Allow these keyboards to control monitor A only monitor B only both or neither gt gt gt Network setup Set DHCP to Yes to have IP address subnet mask and default gateway assigned automatically by the network server The actual values are displayed Enter a Divar name to be used in the network e Fill in the IP subnet mask and default gateway addresses when DHCP is set to No If required change the default http port 80 to a new value The MAC address is read only If Discovery is set to Enabled the Control Center can carry out automatic discovery and read the IP address of the unit e Restrict the network bandwidth by entering an Mbps between 0 and 100 for the bandwidth limit gt gt gt Network access e Access to the unit via the network can be set for up to six different users e Restrict access to the unit by listing an IP address range The range you use will normally depend on your network setup Select a user number to set up the configuration for that remote user The administrator is user 1 and is identified as ADMINISTRATOR IP Range Eight IP ranges can be entered to allow access
22. offers a very user friendly alternative It also allows configuration settings to be saved on the PC hard disk These can be restored later and used to configure other units Bosch Security Systems Divar Installation Manual Using the Configuration Tool Getting started To use the Configuration Tool to change settings the unit must be physically connected to a PC via the RS232 Console Port or via a network connection The Configuration Tool application must be installed on the PC System requirements Operating platform APC or compatible running Windows 95 Windows 98 Windows Millennium Windows NT 4 0 SP4 Windows 2000 or Windows XP For the Configuration Tool application the minimum PC requirements are e Processor 200 MHz Pentium with MMX or equivalent 32 MB depends on operating system 15 MB free 800x600 with 16 bit color A free RS232 port or a 10 100 BaseT network interface RAM memory e Hard disk space e Video system e Connectivity Installing the Configuration Tool The Configuration Tool is automatically installed on the PC when you install the Control Center application To install separately 1 Insert the CD ROM into the CD ROM drive on your PC gt The installation program starts automatically 2 If installation does not start automatically locate the Setup exe file on the CD and double click it 3 Follow the instructions on the screen and select to install the Configuration
23. stand alone configuration If you do have a PC connected to the unit or the unit is used in a network environment then the Configuration Tool offers a more convenient way of accessing and using the menu In both cases the parameters available are the same Slight differences in navigation and selection are only due to the differences between the keys on the unit and the keyboard and mouse interface of the PC The menu structure is the same in both cases This chapter explains how to use the keys on the unit to access the menus It also documents the full structure of the menu system To find out how to use the PC based Configuration Tool refer to Chapter 6 Bosch Security Systems Divar Installation Manual Menu system Overview of the menu system The main menu consists of six menu groups History The History menu allows you to trace all events that have occurred on the unit Disk manager The Disk Manager menu provides information and functions that relate to the maintenance of the storage system including internal and external hard disks Time Date The Time Date menu is used to set the actual reference time and date for the unit and the format that is used to display them View settings The View Settings menu is used to program how the individual cameras are displayed on the monitors System settings The System Settings menu is where most of the static parameters for the unit are set Profiles The Profiles menu i
24. time can vary from 1 to 60 seconds The default value is 5 seconds gt gt gt List Full screen monitor A The sequence list shows the order in which the camera images are displayed in full screen mode Control Center version 1 only Use the arrow keys to select a position in the list Press a camera key on the unit to enter a camera number in the list Press F2 to clear the rest of the list Press Fl to restore all defaults Connected cameras are then listed in ascending order gt gt gt List Full screen monitor B The sequence list shows the order in which the camera images are displayed in full screen mode Control Center version 1 only Use the arrow keys to select a position in the list Press a camera key on the unit to enter a camera number in the list Press F2 to clear the rest of the list Press Fl to restore all defaults Connected cameras are then listed in ascending order gt gt CONFIGURE MONITORS To view camera names and time and date on a monitor set these items to On Set Motion Display to On to draw attention to any motion that occurs in the designated zones Select the position for the text top or bottom and fine position 11 11 Select text intensity Select the border intensity of the cameos from four values To automatically close the menu when an alarm or event occurs set the Exit Menu on Alarms item to Yes The menu is closed after five minutes if you set the
25. to this position when the numbered input is activated e Select up to four cameras to be displayed in sequence Alarm Input Mapping Only shown if alarm panel is connected and enabled The control console type is displayed For each of the 16 alarm inputs select either the physical Divar input the physical input is automattically mapped to its corresponding alarm input number or an input from the control console Alarm Panel 1 to Alarm Panel 238 Bosch Security Systems Divar Installation Manual Menu system EN 5 11 Auto protect Four inputs can be used to trigger automatic protection of video clips Select the inputs you want to use for each of these triggers Set to None if you do not want automatic protection Select the length of time 1 to 60 minutes that you want protected before and after the event These values are valid for all four inputs Select the percentage of hard disk space you want to reserve for auto protected recordings and the behaviour of the Divar if this percentage is reached warn only stop auto protect recording or overwrite the oldest auto protected clips gt gt gt Motion Setup Using motion detection outdoors may cause false alarms because of varying light conditions To restore the default motion settings select the Clear Motion Settings item Select the Display Monitor submenu to set up the view mode and cameras to be activated on the monitor for each motion event
26. unit The Baud rate can be selected in the menu system The serial RS232 console port connector is also used to connect Bosch D9000 series control panels via an interface unit for Divar alarm activation Alarm input mapping can be set up in the menu system Specification Connector type 9 pole D type male connector Maximum input voltage 25V Communicaton protocol Output signals according EIA TIA 232 F RS232 console port socket Signal Name Description DCD_in 1 Carrier detection signal not used RX 2 RS232 receive signal TX 3 RS232 transmit signal N C 4 No Connection System Ground 5 System Ground N C 6 No Connection RTS 7 RS232 request to send signal CTS 8 RS232 clear to send signal N C 9 No Connection Panel view Bosch Security Systems Divar Installation Manual Hardware setup Keyboard connections The keyboard input and output connectors are used to connect an external keyboard to the unit Connect the keyboard to the KBD IN connector Up to 4 external keyboards can be connected when the optional keyboard port expander LTC2604 is used For short distances up to 30m standard 6 core telecom flat cable can be used to supply power and signal connections for the keyboard For distances over 30m between keyboard and Divar the Keyboard Extension Kit LTC 8557 must be used This kit provides junction boxes cables and the appropriate power supply for t
27. vi FCC amp ICES INFORMATION Reference U S A and Canadian Models Only This is a Class B product This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undisired operation Definition of terms Cameo Single camera picture in a multiscreen display Dwell time The length of time that an alarm indicator continues to operate after the event causing it has occurred The length of time a single image of a sequence is shown Full screen A display that only shows one picture occupying a full screen Multiscreen The division of a display screen so that it shows a certain number The internal DVD writer is a laser product The following classification label is of cameras at the same time located on the drive Sequence Camera pictures shown one after the other in time either in full screen or quad modes CLASS 1 LASER PRODUCT Quad Four camera pictures shown on one display screen CAUTION INVISIBLE LASER RADIATION WHEN OPEN AVOID EXPOSURE TO BEAM Icons shown on the screen Play forward Pause ry Alarm Freeze E Motion Zoom Network Sequence 1 Error Play reverse He Fast reverse E ol El E K EN Fast forward eq Bosch Security Systems Divar Installation Manual Introduct
28. weeks for the latest recordings The linear mode first gives a warning and then stops recording when the disk is full Older recordings must be manually deleted Set the Pre event time so that recording begins before an alarm is activated The maximum is 30 seconds Bosch Security Systems Divar Installation Manual Menu system EN 5 10 gt gt gt Disk Full Alarm Setup Set the percentage of used disk space at which the disk full warning message is displayed Set the time in minutes before the disk is full at which a disk full alarm is generated Select the number of the output relay that is activated when a disk full alarm is generated Enable the beeper to activate it when a disk full alarm is generated gt gt PLAYBACK SETUP Use the Playback Setup list to block the playback of recordings from particular cameras after a specified period of time e Choose from No Block 1 to 7 days 14 days 21 days 28 days or 31 days When the specified time has elapsed the recordings of that camera from before that time cannot be played back gt gt EVENT SETUP Use the Event Setup menu to specify the display behavior for an input detected motion or video loss Set the Alarm Dwell Time to select the period during which the output relay and the beeper remain active after activation e Set the Trigger Dwell Time to select the period during which the triggered view mode is displayed after activation The value F
29. 14 Bi phase control ch 5 plus Shield 15 System ground cable shield Bosch Security Systems Divar Installation Manual Hardware setup EN 4 7 External I O connection Alarm inputs and outputs are supplied via a 25 pole D type socket The screw terminal input output connection board supplied with the unit simplifies all alarm connections to the unit O O O O O O O O O 00 0 0 0 Panel view Connecting the Inputs Each alarm input line can be switched by a relay contact from devices such as pressure pads passive infra red detectors smoke detectors and similar devices Wire them as either N O or N C You can configure the alarm inputs as N O or N C in the menu system The default is N O Connecting the Alarm Outputs The four alarm output relays respond to input alarms and triggers You can configure the alarm outputs as N O or N C in the menu system The relays are active for the duration of the driving event Connect the application to the alarm output relays resistive loads only Do not exceed 30 Vac 40Vdc 500 mA continuous or 10VA on an alarm output relay s contacts The contacts must not be used at AC line voltages Specifications Alarm input impedence Internal pull up 10K to 5V 0 3V min to 30V max Low voltage 0 8V max Input voltage range Input voltage treshold High voltage 2 4V min Switching current resistive 500mA max 10VA max Switching vol
30. Divar Digital Versatile Recorder Security Systems EN Installation Instructions BOSCH Divar Installation Manual EN i Chapters Divar Digital Versatile Recorder Installation manual ONOTAON Introduction Quick install Operating instructions Hardware setup Menu system Using the Configuration Tool Menu default values Technical specifications Bosch Security Systems Divar Installation Manual EN ii Introduction cu Seren dee em owed aden ee 1 1 Digital video recorder for security applications ooooooomm m oo 1 1 VEO a IA 1 2 Features cure A AAA a ea 1 2 On screen helped i048 2 22 Ba re AANA ERNS 1 3 Unpacking i 4 4 00 sae eae ra 1 3 Package contents 4 2 2 ea aes reinen 1 3 Installation environment 2222e2 essen nern een nn 1 3 Associated equipment 2222 eeeee nennen ernennen 1 4 DVD writer iio cosa cr an an a aa 1 4 Q ickinst lleesatss et ia oo 2 1 Primary Connecti nssus ees nee eect att ae ea ea 2 3 Optional connections eba raa EARE nennen nn nen 2 3 Poweringl p ea ra nn Er Re re 2 3 Firsttime USS 5 u Se a ea ee BE a 2 3 Quick install menu gt ete 2 4 Language 2s sed ieee eee nen nn nenne 2 4 Time ZOMG Ss vied AA ea Re 2 4 Time format ir ee Ba ae 2 4 TIME ee WS here 2 4 Date format evisos a ra at 2 4 Daten nern a ee SAA 2 4 AGUVe CAMS ied vis ae Rea aa ee ee ond E aes 2 4 Alarm MONI Oia she ade can ar
31. Full full sequence quad quad sequence multiscreen alarm call up live and playback Monitor B Full full sequence and alarm call up Recording Modes Linear Continuous Continuous with conditional overwrite Mechanical Dimensions 442 x 315 x 66 mm 17 4 x 12 4 x 2 6 inch Weight approx 7 5 kg 16 5 lbs Rack Mount Kit Included For mounting one unit in an ElA 19 inch rack Environmental Temperature Operating version without DVD writer 0 C to 45 C 32 F to 113 F Operating version with DVD writer 5 C to 40 C 41 F to 104 F Storage 25 C to 70 C 13 F to 158 F Relative humidity Operating lt 93 non condensing Storage lt 95 non condensing Electromagnetic Compatibility EMC requirements Safety USA FCC Part 15 Class B EU EMC directive 89 336 EEC Immunity EN50130 4 Emission EN55022 Class B Harmonics EN61000 3 2 Voltage fluctuations EN61000 3 3 USA UL6500 2nd edition EU CE EN60950 2000 Canada CAN CSA E60065 00 Accessories Optional KBD Digital LTC 8557 DVAD DVAS LTC 2605 91 LTC 8782 LTC 2604 DVRXEAPO1 DVRSEAPO2 DVRXEDVD1 Intui Key keyboard with joystick Keyboard Extension Kit LP Storage Array RAID Storage Array Video manager Bi phase code translaters Keyboard port expander ATM POS bridge ATM POS software license External CD DVD writer Bosch Security Systems Divar Installation Manual Technical specifications EN
32. Installation Manual Menu system gt gt AUTHENTICITY CHECK This check verifies that video images and associated data have not been modified Select the period within which the authenticity check runs The default values are the same as the earliest and latest available recording times Press the escape key to cancel the check During the check all other front panel keys are disabled If the result is Not OK the date and time of the tampered video is displayed gt gt STOP RECORDING Set the period for which you wish to temporarily stop recording The maximum period is one hour The duration counts down to zero Alarms are not recorded when recording is interrupted Interruption of recordings is always logged in the history list Recording starts automatically when interrupt period has elapsed gt gt STORAGE SETUP Storage Setup gives an overview of internal and external storage The total disk space available is shown in Gigabytes Any new disks found are disabled by default Select the storage location you wish to enable or disable All recorded video is lost if you change a disk configuration If you choose Yes to continue all video is erased Select Storage Status for an overview of the status of all internal and external disks gt gt gt Storage Status OK if everything is all right e Fail if for some reason the disk is not working properly e Fail reconfigure storage if the disk is not part of the
33. LARMS YES MOTIONS YES NETWORK CONNECTIVITY YES ERRORS YES 2002 03 14 13 00 2002 06 19 20 23 EARLIEST TIME LATEST TIME gt gt HISTORY FILTER e Fill in the date time values to restrict the period for viewing events Select No for those events that you do not wish to see gt gt HISTORY LIST The latest event is shown first Use the right left arrow keys to move through a long history list Ifa date or time has been changed the original values are also displayed Alarm motion and video loss events are stored for a maximum of one month EN 5 4 DISK MANAGER gt The Disk Manager menu gives access to information on the internal hard disk s and any external disks connected The status of the recorded video and associated data is also accessed via this menu Archiving is accessed via this menu Access to some menus may be password protected DISK MANAGER STATUS OVERVIEW gt LOCAL ARCHIVING gt PROTECTED RECORDINGS gt AUTHENTICITY CHECK gt STOP RECORDING gt STORAGE SETUP gt DELETE VIDEO gt ERASE DISK gt gt gt STATUS OVERVIEW Disk Capacity shows the total space available in Gigabytes Used Space shows the total space used by all video recordings including protected recordings Protected Recordings Usage shows the space used by protected recordings that cannot be overwritten The displayed Recording Time Left value depends on the recording options that are set and alar
34. Menu Time out to On Bosch Security Systems Divar Installation Manual Menu system EN 5 9 gt gt gt Multiscreen modes SYSTEM SETTINGS gt e Pressing the multiscreen key on the unit cycles through all enabled Use the System Settings menu to get access to those items that are used to multiple view modes configure the system Enable only those views you wish to see when you use the mulisneen key Gan The multiscreen modes that are available depend on the number of SYSTEM SETTINGS cameras connected and the Divar model LOEWE REITEN QUICK INSTALL gt gt gt gt ATM POS requires bridge and license OR BT SERIE N e ATM POS data is viewed on monitor A in full screen mode only le a e Select position duration text intensity and font size for display of the ATM POS data EAEN SETUR z e Press the current camera key during Live or Playback mode to neue LOS SETUP di switch the ATM POS data display on and off LOCAL PASSWORDS gt CONNECTIVITY 5 LICENSES g INPUT AND OUTPUT CONTACTS gt FACTORY DEFAULTS Select the language for the menu from the list e Select Quick Install to quickly set up the system The quick install menu is described in Chapter 2 e Ifyou select Factory Defaults all settings in the menu system are reset to their default value gt gt RECORDING SETUP The continuous mode overwrites older recordings when the disk is full You can set an overwrite protection period of up to 15
35. The Motion Area submenu sets the area and sensitivity for each camera Select the number of the output relay that is activated when motion is detected Enable the beeper to activate it when any motion is detected Display mon A Select the camera number that generates the motion event If you have controllable cameras set a camera number and a pre position number The specified camera goes to this position when motion is detected by the selected camera not necessarily the controllable camera Select a view mode Only view modes that are enabled can be selected If you have selected the full screen or quad view mode select the cameras to be displayed Display mon B Select the camera number that generates the motion event e Ifyou have controllable cameras set a camera number and a pre position number The specified camera goes to this position when motion is detected by the selected camera not necessarily the controllable camera e Select up to four cameras to be displayed in sequence Motion area e Select a camera number The motion indicator shows the maximum level of camera motion that has been detected for the defined area Press F2 to clear it if you want to re test the level of motion detection Use the arrow keys to adjust the Trigger level slider to just below the indicated motion level A motion detection signal is generated when the level of motion reaches the trigger level set Edit area e
36. ULT GATEWAY e Fill in the IP subnet mask and default gateway addresses when DHCP is set to No gt gt MAC ADDRESS The MAC address is read only EN 2 6 gt gt BANDWIDTH LIMIT Restrict the network bandwidth by entering an MBPS between 0 and 100 for the bandwidth limit Bosch Security Systems Divar Installation Manual Operating instructions EN 3 1 CHAPTER 3 Operating instructions The instructions in this chapter explain the purpose of the front panel keys The functions available can be limited by setting passwords Some functions may also require a software license An administrator has access to many more functions in the menu Refer to Chapter 5 Advanced Menu Setup for a full list of available menu items Bosch Security Systems Divar Installation Manual Operating instructions EN 3 2 Front panel controls Divar Bilinx Divar Bilinx Digital versatile Recorder mo Search ve 5 Divar Bilinx with internal DVD writer DVD writer Open Close button DVD writer Read Write LED Divar Bilinx Digital Versatile Recorder Bosch Security Systems Divar Installation Manual Operating instructions Indicators The power indicator KO lights to indicate that power is being supplied to the unit The indicators across the top of the controls light or flash to alert you to various operating conditions REC Record lights when the unit is record
37. able GT Start time It Msn Mm foo 2 End time past Er Jos Er 75 Offset f fife ERAS 2003 12 22 10 19 47 Not connected to Divar Z Overview button Click the Overview button S to get general information about the Divar that is connected EN 6 5 History button Click the History button S to display a list of events in the center pane This list can be filtered to show only those events you want to see e Fill in the date time values to restrict the period for viewing events Uncheck those type of events that you do not wish to see The latest event is shown first If a date or time has been changed the original values are also displayed Press More to see more events Settings button Click the Settings button fo to display the menu for configuring the Divar The menu tree structure and the selected submenu is shown in the center pane Using the Menu tree When you click the Settings button EU the menu tree is displayed on the left of the center pane Use this tree to navigate through the menu system e Click to expand the branch structure e Click to collapse it e Click an entry to display the parameters for that menu item e Select the values you want for the parameters These values are updated immediately Bosch Security Systems Divar Installation Manual Using the Configuration Tool EN 6 6 Service button Click the Service button to get a list of
38. alendar that automatically selects profiles These profiles can be configured for day night weekend or holidays for example PROFILES CURRENTLY ACTIVE 1 CALENDAR SETUP gt PROFILE OVERRIDE gt PROFILE MANAGER gt SYSTEM BEHAVIOR gt gt gt CALENDAR SETUP The use of profiles is defined in a calendar that covers one week This calendar is then repeated for subsequent weeks A profile is specified at intervals of 15 minutes for each day of the week You can program exception days to change profiles for special days and holidays gt gt gt Calendar edit The Calendar Edit menu shows the profile identification numbers used in a 24 hour period 0 to 23 Each hour is divided into four 15 minute periods To see the other days of the week use the left right arrow keys e Select the Add Schedule item to edit the calendar Bosch Security Systems Divar Installation Manual Menu system Add schedule e Select the profile name the begin and end times and the days on which you want the profile to be active Only five profiles changes can occur in any one day Select a number from 0 to 23 for the hour Select between 0 15 30 or 45 for the minutes Ifthe begin time is later than the end time then the profile is active from the end time until the begin time on the next day gt gt gt Exception days Up to 32 exception days can be set that override the calendar list Use the up down keys to mo
39. ate er een 2 4 Recording settings 0 0 ccc ees 2 4 Network settings ogre e ccc cece 2 4 DAVE GcOXIt aces eg vie E Sve wana wen eed 2 4 Cancel ess iets Maca Vedat woe aa Poon ceed ee 2 4 Recording settings 0 0 ccc cece 2 5 Day Period E aac een 2 5 Weekend ia A 2 5 REES ee z 2 5 Rec weekend night 0 0 ccc cece ees 2 5 Enable alarm inputs foro 0 cece teens 2 5 Alarm input recording 0 0 cece 2 5 Enable motion for 0 cece cee cece ee con 2 5 Motion recording sarasa E eens 2 5 Approximate recording duration 1 0 0 cece eee ees 2 6 Network settings 0 0 0 ccc cece cece ete 2 6 DAG Sra nee 2 6 DVR name ae anne 2 6 IP address Subnet mask and Default gateway 04 2 6 MAG address ci Ren 2 6 Bandwidth limit 0 0 nennen nenn nern nen 2 6 Operating instructions 0 0c eee 3 1 Front panel controls ssai asai ccc cect rennen nen 3 2 INICALONS a esa en re a aed Son dene dcr 3 2 KO YS ieee A a 3 2 Primary f neti nsa 23 2 ze ER age 3 3 Alternate functions oooooocooccoc et een nenn 3 4 VIEWING PICTURES ciar aa Pe lah ea na ee anne in endende ne 3 5 VIEWING 2x at dao nenn ee ee ee a a een Mee ak a 3 5 Live playback and search modes cece eee 3 8 Liv MOG ica erg A AAA wer 3 8 Playbackmode occ scsi eee ee ee RR EE a 3 8 Search mode u Fer Pee ee a aes 3 9 Search criteria ee rr 3 9 Search resultS ioris ada Ek TE aa eee 3 10 Triggers and alarms c er
40. bmenu is for motion events The list gives an overview of inputs and motions that are used in any of the profiles A check mark means used Normal Select the profile The Unallocated IPS item shows the IPS capacity remaining A total of 60 images per second IPS can be recorded for NTSC 50 IPS for PAL A minimum of 1 IPS is always allocated per camera for pre alarm recording and network viewing Set the recording rates and quality levels for each camera Quality is standard medium or high IPS rates for PAL range from Never 0 1 10 one image every 10 seconds up to 25 IPS IPS rates for NTSC range from Never 0 1 10 one image every 10 seconds up to 30 IPS Set the recording speed to NEVER to not record a camera at all No pre alarm recording is done and the camera cannot be viewed over the network No ATM POS data is recorded EN 5 15 Input Each input when activated can change the normal recording behavior of up to four cameras for a maximum of 120 seconds Select the profile Select the input number Select the cameras whose recording behavior should change Set the recording rates and quality levels for each camera Set camera name to None to use less than four cameras To free IPS bandwidth the recording rate of cameras not in alarm is limited to the IPS number displayed Motion Each motion input when activated can change the normal recording behavior of up to four cameras for a maximum of 120 s
41. ced display of pre programmed cameras The alarm beeper sounds The alarm EN and the indicators flash e A controllable camera might be moved to a pre defined position Acknowledging an input alarm 1 Press the acknowledge key to acknowledge the alarm gt The beeper is silent gt The alarm EN and indicators are no longer lit gt The alarm status message disappears gt The last used view mode is restored The alarm icon remains visible as long as the input causing the alarm is active If an alarm is not acknowledged the beeper switches off after the dwell time but the alarm still needs to be acknowledged If auto acknowledge is enabled the beeper and the alarm EN and indicators switch off after the dwell time EN 3 13 Motion alarm If a motion detection signal causes an alarm e Monitors A and B can switch to a pre programmed view mode Monitor A The border around the displayed cameos is yellow The motion icon is displayed in each cameo An alarm status message is displayed Monitor B Sequenced display of pre programmed cameras e The alarm beeper sounds The motion EX and the BW indicators flash e A controllable camera might be moved to a pre defined position Acknowledging a motion alarm 1 Press the acknowledge key to acknowledge the alarm gt The beeper is silent gt The motion and indicators are no longer lit gt The alarm status message disappears gt The last used view
42. cted to the BNC connectors if your Divar version is Bilinx enabled If Bilinx cameras are looped through to multiple Divars only one Divar is allowed to have Bilinx enabled Specification Input signal Composite video 1Vpp 75 Ohm Embedded Bilinx command protocol Divar Bilinx only PAL NTSC auto detect Automatic or manual gain control for each video input Color standard Gain control Connector type BNC looped through automatic termination Bosch Security Systems Divar Installation Manual Hardware setup Monitor connections Connect the unit to the monitors using 75 ohm video coaxial cables with BNC connectors The unit provides a 1Vpp CVBS signal If the monitor has a loop through connection and you are not using the loop through output then select the 75 ohm impedance setting on the monitor If the monitor s loop through output is connected to an additional device the device s termination is set to 75 ohms and the monitor s termination is set to high impedance Note that this is not necessary on devices with automatic termination Specifications Output signal Composite video 1Vpp 75 Ohm Sync 0 3Vpp 10 720 x 576 PAL 720 X 484 NTSC Connector type BNC Resolution EN 4 3 Console port connection The serial RS232 console port connector is used to connect a PC to the unit for configuration or service purposes Use a null modem cable to connect the serial port of the PC to the
43. e Login window appears Click Cancel to discontinue login and exit the application U Login Select Divar Building 3 Divars amp ACar park Divars IV DIVAR 05 TDIVAR 07 Account User name ADMINISTRATOR Password i Save login information Login WE Cancer To control a particular Divar 1 Select the Divars you want to control by placing check marks next to them gt Click to either select all or none of the Divars listed gt If a login group has been defined you can select this group to log in to the Divars listed in the group 2 Type your user name and password gt The user name and password to be filled in are set in the System settings Connectivity Network access menu of the Divar itself Check with your administrator if you do not have access to the unit gt To let the system remember your name and password on subsequent uses of the Control Center place a check mark in the Save login information box 3 Click Login EN 6 4 Maximum number of users If the maximum number of users for the Control Center is exceeded a window is displayed An administrator can use this window to force off a user The list shows all users that are currently logged in To disconnect a user 1 Select a user in the list 2 Click Yes Menu structure differences The Configuration Tool allows you to access and use menu items of the unit These menu items are explained in Chapter 5 Although the
44. e minute earlier Press the play key Il to resume playback from the last selected playback position Press the live key to switch back to live viewing An alarm also switches the unit back to live viewing EN 3 9 Playback mode In playback mode the video control keys operate as follows e Press the rewind key EI to start reverse play of recordings Pressing it again and again increases the display rate to a maximum and then back to normal speed again Press the rewind key BJ in the pause mode to step back one field at a time Press the pause key IN to freeze the picture e Press the forward key EM to start forward playback of recordings Pressing it again and again increases the display rate to a maximum and then back to normal speed again Press the forward key EJ in the pause mode to step forward one field at a time Press the play key Il to resume playback Press the current camera key to switch the ATM POS display on and off Press the live key to switch back to live viewing or press the search key to switch to the search mode In both cases playback stops Bosch Security Systems Divar Installation Manual Operating instructions EN 3 10 Protecting or archiving a video recording 1 Press the pause key MI for longer than one second during playback to mark the beginning of a video segment for protection or archiving gt A dialog window appears gt The time and date of the marker
45. ears each for a pre programmed dwell time 2 Press the ALT key and then the sequence key to stop sequencing gt Zooming pressing the multiscreen key or selecting a single camera also stops sequencing EN 3 7 Cameo assignment Assigning cameras to cameos in a multiscreen view 1 Press the ALT key and then the multiscreen key E gt The multiscreen key indicator flashes gt The border around the active cameo is green gt The camera key of the camera shown in the active cameo lights green 2 Use the arrow keys if you wish to select a different cameo 3 Press a camera key to display that camera s picture in the active cameo gt The camera is assigned and the following cameo becomes active 4 Continue to press camera keys to assign camera pictures to cameos Press the ALT key to interrupt cameo assignment and exit the assignment mode gt The assignment mode is automatically ended when the last cameo has been assigned The cameo assignment that you make is used in playback mode as well as in live mode Image freeze Freezing a camera shot on monitor A 1 Press the pause key IM to freeze the picture in the active cameo 2 Press the pause key MI again to return to live viewing If you are viewing a camera picture in full screen mode then this picture is frozen The zoom function can be used on a frozen picture If you change viewing mode any frozen pictures are released Bosch Security Systems
46. econds Select the profile Select the motion camera number Select the cameras whose recording behavior should change Set the recording rates and quality levels for each camera Set camera name to None to use less than four cameras To free IPS bandwidth the recording rate of cameras not in alarm is limited to the IPS number displayed gt gt gt Access restrictions Remote access restrictions can be set for each of the six profiles Select the profile Select if local playback is enabled or not Select which remote users have access and which are blocked Remote user 1 the administrator always has access gt gt gt Copy system behavior To copy the settings of one profile to another enter the number of the source profile enter the number of the destination profile and select the Copy Now item Bosch Security Systems Divar Installation Manual Menu system EN 5 16 Bosch Security Systems Divar Installation Manual Using the Configuration Tool EN 6 1 CHAPTER 6 Using the Configuration Tool The Configuration Tool is a software application that makes the installation and configuration of a unit faster and easier The Configuration Tool runs on a PC that is connected to the Divar either directly via an RS232 serial connection or via an Ethernet network connection Although all settings can also be configured with the on screen display menu of the Divar itself the Configuration Tool
47. ecurity Systems Divar Installation Manual Menu system EN 5 3 MAIN MENU Main menu The main menu gives access to six major menu groups Each of these groups has History a submenu tree where the values and functions can be selected Ee ara Set Advanced Menus to Yes to see all items set to No for standard a a features only Profiles Advanced menus EF history HISTORY ES View history list DISK MANAGER Disk manager TIME DATE gt Status overview Local archiving ero ah Protected recordings SYSTEM SETTINGS gt Authenticity check Stop recording PROFILES gt Storage setup ADVANCED MENUS NO Delete video Erase disk Time Date View settings Camera setup Sequences Configure monitors System settings Language Quick install Record setup Playback setup Event setup History log setup Local passwords Connectivity Licenses Input and output contacts Factory defaults Profiles Currently active Calendar setup Profile override Profile manager System behavior advanced items Bosch Security Systems Divar Installation Manual Menu system HISTORY gt The History menu provides a list of all events that have occurred This list can be filtered to show only those events you wish to see VIEW HISTORY LIST gt BEGIN TIME 2002 03 14 13 00 END TIME 2002 06 19 20 23 SHOW A
48. em without saving press to leave help system a DEEA Menu key Mon A key Mon B key Sequence key Zoom key opens the menu system assigns front panel keys to monitor A assigns front panel keys to monitor B view cameras in sequence on full screen or quad displays zooms in on the active camera display full screen or active cameo Bosch Security Systems Divar Installation Manual Operating instructions Viewing pictures The unit has two monitor outputs A and B The way in which these monitors display pictures depends on how the system has been set up Monitor A Monitor A is the main monitor It shows full screen quad or multiscreen live or playback camera pictures Status messages alarms motion and video loss warnings are also displayed on this monitor When the menu system is activated it is displayed on this monitor Monitor B Monitor B displays a single full screen picture of a selected camera or a sequence of full screen pictures When an alarm or motion input is detected the camera picture with the Alarm Motion indicator can be displayed on monitor B When multiple alarms or motion occur camera pictures are sequenced on monitor B Selecting a monitor to control To control the display on monitor A 1 Check that the light on the front panel is lit 2 If is not lit press the ALT key and then press the monitor A key E To control the display on monitor B 1 Check that the
49. evel 2 Level 3 Level 4 Level 5 Default value Motion Cameras not in alarm IPS No change Recording duration 15 seconds Access restrictions Select profile 1 Local playback password Disable User 2 Access User 3 Access User 4 Access User 5 Access User 6 Access Copy system behavior Copy from None Copy to None Advanced No menus Bosch Security Systems Divar Installation Manual Technical specifications EN 8 1 cuaprers Technical specifications The following pages give the technical specifications of the unit Bosch Security Systems Divar Installation Manual Technical specifications Electrical Voltage and Power All models Video Video standard Resolution AGC Digital Zoom Compression Inputs Outputs Alarm Handling Inputs Outputs Control RS232 Keyboard input Keyboard output Bi Phase 100 240 VAC 0 7 0 3A 50 60Hz PAL NTSC auto detect 720 x 576 PAL 720 x 484 NTSC Automatic adjustment or manual adjustment of gain for each video input 2 or 4 times WAVELET composite video 0 5 2Vpp 75 ohm automatic termination 1Vpp 75 ohm sync 0 3 V 10 16 configurable NO NC max input voltage 40 VDC 4 relay outputs configurable NO NC max rated 30 VAC 40 VDC 0 5A continuous 10VA Output signals according EIA TIA 232 F max input voltage 25V Conform RS485 max signal voltage 12V supply 11V 12 6V at max 400mA Co
50. h screw terminals used for PTZ connections e Power supply cord Network cross over cable e Serial RS232 cross over null modem cable e Divar loop through cable e Rack mounting kit A CD ROM with the software and the manuals SCSI terminator mounted on the SCSI connector do not remove unless an external SCSI device is to be connected Installation environment Mounting The Divar is supplied as a desktop unit If desired the unit may be rack mounted using the rack mounting kit supplied with the unit Ventilation Ensure that the location planned for the installation of the unit is well ventilated Take note of the locations of the cooling vents in the unit s enclosure and ensure that they are not obstructed Temperature Observe the unit s ambient temperature specifications when choosing an installation space Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail Do not install the unit on top of hot equipment Power Supply Ensure that the site s AC power supply is stable and within the rated voltage of the unit If the site s AC power is likely to have spikes or power dips use power line conditioning or an uninterruptable power supply UPS Bosch Security Systems Divar Installation Manual Introduction EN 1 4 Associated equipment A typical system could contain the following components not included with the unit DVD writer A
51. he external keyboards The recommended cable type is Belden 9841 or equivalent Divar connection The KBD IN and KBD OUT connectors can also be used to connect several Divar units to each other The loop through connector arrangement allows easy interconnection of up to 30 Divars The connection uses RS485 based communications The RS485 connection is not galvanically separated If you have an installation where Divars are connected via RS485 and they are not located close to each other you must ensure that they are grounded via the same clean grounding wire Specifications Communicaton protocol RS485 Maximum signal voltage 12V Power supply 11 12 6V maximum 400mA Maximum cable length 1 5 kilometers Cable type black cross over cable supplied with keyboard Termination 390 Ohm terminator EN 4 4 Keyboard In RJ11 socket KBD IN Pin no Signal 12 V DC 11V Min to 12 6V Max 400mA Max System ground Keyboard plus line Keyboard minus line System ground O o PO Dm System ground Keyboard out RJ11 socket KBD OUT Pinno Signal No Connection System ground Keyboard minus line Keyboard plus line System ground o O KR oO nN No Connection IN KBD OUT Panel view Bosch Security Systems Divar Installation Manual Hardware setup EN 4 5 Ethernet connection
52. ing video 2 Network lights when a remote user is connected to the unit A Alarm flashes when an alarm is detected Motion flashes when motion is detected in a camera signal Video loss flashes when a video loss condition is detected for a camera input EN 3 3 Keys The keys on the front panel can be used for controlling primary functions or alternate functions Symbols for the primary functions are shown above the keys Symbols for the alternate functions are shown below the keys The alternate functions are activated by first pressing the ALT key and then the desired key When the alternate function mode is active the light below the ALT key is lit The unit automatically exits the alternate mode if the monitor A key A monitor B key 2 or sequence key E is pressed When in a menu the keys operate according to their alternate function Bosch Security Systems Divar Installation Manual Operating instructions Primary functions light below ALT key off Live key Search key z Reverse key EIN pase key E py key gt Fast forward press to switch to live viewing press to open a search menu to look for recorded events in live mode press to start reverse playback of recordings for the displayed cameras in playback mode press to speed up rewind in pause mode press to step back one frame in live mode press to freeze a camera picture in the playback mode
53. ion EN 1 1 CHAPTER 1 Introduction Digital video recorder for security applications The Divar is a video recording system that can record multiple camera signals while simultaneously providing live multiscreen viewing and playback It combines the functionality of a digital recorder with a multiplexer and a switcher The unit has comprehensive search including a smart motion search and playback facilities for viewing stored video Once set up all recording takes place in the background without requiring operator intervention Maximum recording rates of 60 NTSC and 50 PAL images per second in total are guaranteed with unsynchronized cameras The recording rate and quality are selectable per camera All models have extensive alarm handling functions and telemetry control Alarm functions include motion detection in user definable areas of the image on any camera input The unit can be easily operated and programmed via the front panel control keys and on screen display menu system One monitor output provides full screen quad and multiscreen viewing another spot alarm monitoring A keyboard can be connected for PTZ control and to improve the ease of use Via a network the Control Center PC application can be used for live viewing playback and configuration Six simultaneous users can control multiple Divars The Divar includes an authenticity check for both local and remote playback A dedicated PC player is provided fo
54. items are the same the menu structure is slightly different in the Configuration Tool The History menu item is removed from the menu tree structure and is now accessed via the History button The Disk manager submenu is replaced by the Storage setup item of the menu tree structure in the Configuration Tool As a result of the windows interface selection and editing of some functions with the Configuration Tool is different to the methods used on the unit itself For example scroll bars are used instead of the arrow keys the motion area selection interface is simpler and the Calendar edit item of the Profiles menu uses a color code to add profiles to the calendar The Configuration Tool interface although different is intuitive and does not change the functionality of the menu items Bosch Security Systems Divar Installation Manual Using the Configuration Tool Introducing the main window The Configuration Tool window is divided into 3 panes The buttons in the left pane are always available Clicking one of these buttons changes the contents of the center pane The buttons in the right pane are control buttons that give you direct access to various tasks Configuration Tool Offline Time date Date Time e AI zj Actual 2000 01 01 107898 00 00 00 Format E Synchronize L Storage setup Gal i bs ia Network time server Enable 0 0 0 0 Synchronize Daylight saving ylight saving I En
55. les gt gt NETWORK SETTINGS Opens network settings submenu to fill in the settings that control the behavior of the unit with respect to a network gt gt SAVE amp EXIT e Select this item to load the settings you have made into the unit and exit the Quick Install gt gt CANCEL e Select this item to exit the Quick Install without saving Bosch Security Systems Divar Installation Manual Quick install gt gt RECORDING SETTINGS RECORDING SETTINGS DAY PERIOD 8 00 18 00 WEEKEND SAT AND SUN REC DAY 1 IPS CAM REC WEEKEND NIGHT 2 IPS CAM ENABLE ALARM INPUTS FOR DAY NIGHT ALARM INPUT RECORDING 12 5 IPS INPUT ENABLE MOTION FOR NIGHT a Ze SE LO S at asp ala Us all MOTION RECORDING 5 IPS CAM APPROX REC DURATION 036 HOURS gt gt DAY PERIOD e Fill in a start time and an end time to define the period during which the day profile is active e The weekend night profile is active for the rest of the 24 hour period gt gt WEEKEND e When a day is defined as a weekend day then the weekend night profile is active that whole day Define the weekend as either Saturday and Sunday or just Sunday Select none if you wish the weekend to be the same as the other days of the week gt gt REC DAY e Select the normal recording speed to be used for each of the activated cameras during the day profile The I
56. light on the front panel is lit 2 If is not lit press the ALT key and then press the monitor B key E Viewing EN 3 6 The drawing shows all possible views for monitor A Some multiscreen views may have been disabled during set up The Divar model and the number of connected cameras can also influence the multiscreen views available 4 3 4 l 2 3 8 4 5 Il 6 7 13 5 1 a 2 8 I 3 4 5 6 The quad mode can have 4 different quad screens that can be shown in sequence to display 16 camera pictures Bosch Security Systems Divar Installation Manual Operating instructions Multiscreen To view different multiscreen displays on monitor A 1 Press the multiscreen key E gt A multiscreen display of camera pictures appears on monitor A 2 Press the multiscreen key again to go to the next programmed multiscreen view gt If you continue to press the multiscreen key EI the unit cycles through all enabled multiscreen views Full screen To view a full screen shot of a camera 1 Press a camera key gt A full screen shot of the camera you selected appears gt The camera key of the selected camera lights green 2 Press the multiscreen key El to go back to your previous multiscreen view on monitor A Sequence To view a sequence of live camera pictures of several cameras 1 Press the ALT key il and then the sequence key 8 gt The indicator lights gt A sequence of camera pictures app
57. m Setup Disk Full warning 95 Disk Full alarm 1 min Output relay None Beeper Disable Playback Setup List of camera block after No block Event Setup Alarm dwell time 5 seconds Trigger dwell time 5 seconds Input Setup Output relay Relay 1 Beeper Enable Display monitor A Camera pre positions None PPO1 Display monitor B Camera pre positions None PPO1 Input name INPUT 01 INPUT 16 Auto protect Input 1 to 4 None Protected before event 5 minutes Bosch Security Systems Level 1 Level 2 Level 3 Level 4 Level 5 Default value Protected after event 10 minutes Max auto protected 25 of disk On max auto protect Warning only Motion Setup Output relay None Beeper Disable Video loss Setup Display monitor A Yes Display monitor B No Output relay Relay 2 Beeper Enable History log setup Log alarms Yes Log motions Yes Log video loss Yes Log errors Yes Log network Yes Connectivity Keyboard access Keyboard 1 Both Keyboard 2 Both Keyboard 3 Both Keyboard 4 Both Network setup DHCP Yes Discovery Enabled DVR name DIVAR Bosch Security Systems Divar Installation Manual Menu default values EN 7 6 Level 1 Level 2 Level 3 Level 4 Level 5 Default value Default gateway 0 0 0 0 HTTP port 80 Bandwidth limit 100 MBPS Network access IP Range
58. m and motion frequency The estimated recording time shown depends on the available storage capacity and recording setup Bosch Security Systems Divar Installation Manual Menu system gt gt LOCAL ARCHIVING Segments of recorded video can be written to re writable disks using the local archiving menu Select Archive Setup to check the status of the writer the progress of the writing or to erase or format rewritable disks Select Archive Session to make a list of the video segments to be archived and to start writing gt gt gt Archive Setup e Progress is shown as a percentage of the current activity e Select Cancel Archiving or press F2 to stop the current archive session this can result in an unusable disk e Set Finalize to Yes if the disk is to be finalized after archiving Select Erase Rewritable to remove all data from a rewritable disk Free Space shows the free space available on the inserted disk gt gt gt Archiving Session e Fill in a begin and end date and time for the video segment you wish to archive Select Add to Archive List or press F2 to place it in the list All recorded cameras in the time span are selected e Select View Archive List to review the selected video segments and to start the archiving procedure The archive list is saved until archiving is carried out Video segments that have been partially overwritten or deleted are removed from the list View Archive
59. mages Per Second IPS rates available for PAL range from Never 0 1 10 one image every 10 seconds up to 25 IPS The Images Per Second IPS rates available for NTSC range from Never 0 1 10 one image every 10 seconds up to 30 IPS EN 2 5 e Set the recording speed to NEVER to not record a camera at all No pre alarm recording is done and the camera cannot be viewed over the network gt gt REC WEEKEND NIGHT e Select the normal recording speed to be used for each of the activated cameras during the weekend night profile The Images Per Second IPS rates available for PAL range from Never 0 1 10 one image every 10 seconds up to 25 IPS The Images Per Second IPS rates available for NTSC range from Never 0 1 10 one image every 10 seconds up to 30 IPS Set the recording speed to NEVER to not record a camera at all No pre alarm recording is done and the camera cannot be viewed over the network gt gt ENABLE ALARM INPUTS FOR e Select the profiles during which alarm inputs are enabled Choose day only weekend night only both day and weekend night or none gt gt ALARM INPUT RECORDING An activated input alarm can increase the recording speed of a camera Select the recording speed to be used when an input is activated The camera with the number that corresponds to the alarm input number is recorded at the speed you set gt gt ENABLE MOTION FOR e Select the profiles during which
60. mera control Set the Auto Camera Contrast to On to let the system automatically adjust the contrast for each camera e If you set the Auto Camera Contrast to Off you can access the Adjust Contrast submenu Bosch Security Systems Divar Installation Manual Menu system EN 5 8 gt gt gt gt gt gt Adjust contrast Select a camera in the menu or press a camera key on the unit The selected camera image appears e Vary the manual gain value between 100 and 100 to adjust the contrast To set the default value 0 press the F1 key Camera controllable A check mark under a camera number indicates that it can be controlled remotely by the Control Center application e Press a camera key on the unit to make a camera controllable or not By default all cameras are controllable Bilinx cameras Only shown if your Divar is a Divar Bilinx A check mark under a camera number indicates that Bilinx control is enabled Press a camera key on the unit to enabled or disable Bilinx control for that camera By default all cameras are enabled If Bilinx cameras are looped through to multiple Divars only one Divar is allowed to have Bilinx enabled gt gt SEQUENCES The sequence in which cameras are displayed on monitor A and monitor B is set in the full screen list menu Set the length of time each image remains on the screen by filling in the dwell time value for each monitor Dwell
61. mode is restored The motion icon remains visible as long as the input causing the alarm is active If an alarm is not acknowledged the beeper switches off after the dwell time but the alarm still needs to be acknowledged If auto acknowledge is enabled the beeper and the motion and indicators switch off after the dwell time Using motion detection outdoors may cause false alarms because of varying light conditions Bosch Security Systems Divar Installation Manual Operating instructions Video loss alarm If the loss of a video signal causes an alarm Monitor A or B can be set up to show the video loss signal e Monitor A switches to multiscreen view The lost camera signal is displayed as a black cameo with the video loss message The border around the camera with the video loss is red An alarm status message is displayed e Monitor B Sequenced display of cameras that do not have video loss The alarm beeper sounds e The video loss and the indicators flash Acknowledging a video loss alarm 1 Press the acknowledge key to acknowledge a video loss alarm gt The beeper is silent gt The video loss and indicators are no longer lit gt The alarm status message disappears gt The last used view mode is restored If the camera with video loss is visible the black cameo and the video loss message continue to be displayed as long as there is no video present If an alarm is not acknowledged the beepe
62. motion events are enabled Choose day weekend night both day and weekend night or none Press the camera keys to select or deselect the cameras for which motion should be enabled A check mark means enabled gt gt MOTION RECORDING A camera can be recorded at an increased recording speed when motion is detected Select the recording speed to be used for each of the cameras when motion is detected Bosch Security Systems Divar Installation Manual Quick install gt gt APPROXIMATE RECORDING DURATION This is an estimate of the recording duration based on the total amount of storage space available and the recording setup For event recording the following parameters are used During the day one camera is in input alarm recording 5 of the time and every motion enabled camera is in motion recording 10 of the time During the night and weekend one camera is in input alarm recording 1 of the time and in motion recording for 3 of the time gt gt NETWORK SETTINGS NETWORK SETTINGS DHCP NO DVR NAME DIVAR IP ADDRESS 192 168 10 2 SUBNET MASK 255 255 255 DEFAULT GATEWAY Ge u MAC ADDRESS 00 00 00 00 00 00 BANDWIDTH LIMIT 100 MBPS gt gt DHCP Set DHCP to Yes to have IP address subnet mask and default gateway assigned automatically by the network server The actual values are displayed gt gt DVR NAME Enter a Divar name to be used in the network gt gt IP ADDRESS SUBNET MASK AND DEFA
63. nabled camera inputs Both 6 channel and 9 channel versions operate in exactly the same way except that fewer cameras can be connected there are fewer camera keys and the number of multiscreen views is reduced Instructions that only apply to the internal DVD writer or Bilinx functionality are indicated by a double or EN 1 2 triple asterix respectively If your unit has neither of these facilities then please skip these instructions Features The Divar has the following features e 6 9 or 16 looped through auto terminating camera inputs with embedded Bilinx communication facilities Simultaneous recording and playback Smart motion search Internal hard disk video storage e Narrow SCSI port for external SCSI storage expansion 10 100Base T Ethernet port for Ethernet connection and networking e RS232 serial port for serial communications External keyboard input and output ports for keyboard connection and system expansion Dual monitor outputs e Full screen and various multiscreen display capabilities in live and playback modes Spot monitor output with sequencing and OSD Motion detection e 16 switching alarm inputs and 4 alarm outputs e Compatibility with Bosch D9000 series control panels e Video loss detection e Audible alarm e Automatic protection of video clips on input alarm e Pan tilt and zoom camera control Internal DVD writer Suppo
64. nform RS485 max signal voltage 12V Impedance 128 ohm max Bilinx Connectors Video inputs Ethernet Monitors Alarm connectors Bi Phase RS232 Keyboard input Keyboard output SCSI Storage Hard Disks File sizes Record Rate IPS Recording Resolution EN 8 2 overvoltage protection 40V max cable length 1 5km Bilinx enabled controllable cameras via BNC camera connectors Divar Bilinx version only 6 9 or 16 looping BNC auto terminating RJ45 shielded 10 100 BaseT according IEEE802 3 BNC 2 MON A multiscreen MON B spot alarm Screw terminal input Screw terminal output DB9 male RJ11 6 pin RJ11 4 pin conform RS485 30 units max HD 50 pin max 6 connected ultra SCSI devices 20Mbytes sec 80GB 160GB 320GB 600GB Expandable via SCSI 2 HD50 pin up to 6 external storage arrays 17TB max type DVAD or DVAS High quality 40Kb Medium quality 24Kb Standard quality 16Kb NTSC 60 total configurable per camera 30 15 10 7 5 6 5 4 3 2 1 1 5 1 10 0 Never PAL 50 total configurable per camera 25 12 5 8 6 5 4 3 2 1 Yo 1 5 1 10 O Never 720 x 288 PAL 720 x 242 NTSC Bosch Security Systems Divar Installation Manual Technical specifications EN 8 3 DVD writer Write speeds DVD R DVD RW 4x or higher CD R 40x or higher CD RW 24x or higher Divar write speed 1MB sec approx Display Modes Monitor A
65. nly when set Camera list No cameras locked Set password No password set Bosch Security Systems Divar Installation Manual Menu default values EN 7 3 Level 1 Level 2 Level 3 Level 4 Level 5 Default value Camera control Auto camera contrast On Adjust contrast 0 Camera controllable No cameras selected Bilinx camera enabled All cameras selected for Bilinx version Sequences List Fullscreen monitor A All cameras connected List Fullscreen monitor B All cameras connected Dwell time monitor A 5 seconds Dwell time monitor B 5 seconds Configure Monitors Display titles monitor A On Display titles monitor B On Display time date monitor A On Display time date monitor B On Display motion Off Status position Bottom 0 Text intensity White clear Cameo border intensity Black Exit menu on alarms No Menu time out On ATM POS Position Top left Duration 3 seconds Text intensity White clear Font size Small Bosch Security Systems Divar Installation Manual Menu default values Level 1 Level 2 System Settings Level 3 Level 4 EN 7 4 Level 5 Default value Language English Recording Setup Record mode Continuous Overwrite protection None Pre event time 10 sec Disk Full Alar
66. ollows activates the beeper and relay or view only as long as the event is present gt gt gt Input Setup To restore the default input settings select the Clear Input Settings item Select the Display Monitor submenu to choose the view mode and cameras to be displayed when an input is activated Select the number of the output relay to be activated when any alarm input is activated Enable the beeper to activate it when an alarm input is activated Select the Input Name submenu to assign a name to each of the 16 Divar inputs e Ifan alarm panel is connected to the RS232 port and enabled select the Alarm Input Mapping submenu to associate alarms from the alarm panel with the 16 Divar inputs Select the Auto protect submenu to choose automatic protection of video clips activated by a specified input Display mon A Select the input number 1 to 16 for which you wish to set the view mode e Ifyou have controllable cameras set a camera number and a pre position number The specified camera goes to this position when the numbered input is activated e Select a view mode Only view modes that are enabled can be selected If you have selected the full screen or quad view mode select the cameras to be displayed Display mon B Select the input number 1 to 16 for which you wish to set the view mode Ifyou have controllable cameras set a camera number and a pre position number The specified camera goes
67. on to set the time of the unit from the time of the network Synchronize only works if the Divar time is within 7 minutes of the server time Fill in the IP address of the network time server The time and date of all other connected units are automatically synchronized every hour from the time and date of the unit with DVR ID 1 EN 5 7 VIEW SETTINGS gt The View Settings menu allows you to set up the display of the individual cameras You can also set the sequence in which the cameras are displayed and the duration Use the Configure Monitors submenu to set up the monitor displays VIEW SETTINGS CAMERA SETUP gt SEQUENCES gt CONFIGURE MONITORS gt gt gt CAMERA SETUP Use the Camera Setup menu to access the submenus for setting the camera names for locking cameras and for controlling cameras gt gt gt Camera name e Select a camera by pressing a camera key on the unit The number of the camera is the number of the connector at the rear of the unit to which it is connected Enter a name for the selected camera The name can be up to 16 characters long gt gt gt Camera lock out Locked cameras are not visible during normal use Place a check mark under the number of the camera you wish to lock or press a camera key on the unit to switch the lock on or off e Select the Set Password submenu and fill in a 4 digit password to restrict access to the camera lock out menu gt gt gt Ca
68. ons that appear on your monitor screen to load the latest Archive Player software The DVD writer supports the following write speeds DVD R DVD RW 4x or higher CD R 40x or higher CD RW 24x or higher Bosch Security Systems Divar Installation Manual Quick install EN 2 1 CHAPTER 2 Quick install This chapter gives instructions on how to quickly get the unit operational Make the connections described on the following pages and then enter the relevant data in the quick install menu The Quick Install menu appears the first time you start the unit When you have entered the relevant information the unit will be operational Bosch Security Systems Divar Installation Manual Quick install EN 2 2 Quick connection DIVAR 390 Ohm ATM POS bridge ee ae a a a A ren ae ae Et AutoDome Terminator ETHERNET IN KBD OUT 2 3 ww ee 600006000007 35 AutoDome MN 110 240 Vac can be 6 9 or 16 depending on model Bosch Security Systems Divar Installation Manual Quick install Primary connections 1 Connect the cameras to the BNC loop through camera inputs automatically terminated 2 Connect monitor A to the BNC output MON A Optional connections 3 Connect monitor B to the BNC output MON B 4 Connect up to 16 alarm inputs via the sup
69. oups of settings you want to save and click OK to save the settings Multiple download Click the download button to open a list of the Divars in the network to which you can download selected settings Select those Divars in the list that you want to update Bosch Security Systems Divar Installation Manual Using the Configuration Tool EN 6 7 Refining settings When you select Import Export or Download a pop up window allows you to select particular groups of settings You can select All settings All settings except or Only to determine how the list is constructed To refine your selection click c gt and place a check mark next to the settings you want to include in the list Refresh Click the refresh button to refresh the content of the current page settings only Undo Redo Click these buttons to undo or redo your last action Up to 100 actions can be undone Previous Next Use these buttons to move through the settings menu Click the previous button to go back to the page that was active before the current page Click the next button F gt to activate the next page in the menu system Print When the Overview or History page is active you can print the complete contents of the page or list 1 Click the print button a to print the current settings 2 Click OK to print Save When the Overview or History page is active you can save the complete contents of the page or
70. plied 25 pin D type connector board 5 Connect up to 4 alarm output relays via the supplied 25 pin D type connector board 6 Connect a keyboard unit to the KBD IN socket 7 Connect a pan tilt zoom control unit via the supplied 15 pole D type connector board 8 Connect to your network via the Ethernet port or use the RS232 connector to connect directly to a PC serial port 9 Connect an external storage unit via the narrow 50 pin high density SCSI 2 port For Divars with an internal DVD writer Do not remove the supplied terminator from the SCSI connector unless you connect a disk array Powering up 10 Switch on all connected equipment 11 Connect the power cord to the unit EN 2 3 First time use The unit starts with a multiscreen display The Quick install menu opens the first time you use the unit Fill in these basic settings to get the unit operational Select the Install item to save your settings and close the menu When you close the Quick install menu the unit begins recording automatically To open the Quick install menu at any other time 1 Press the ALT key to enter the alternate function mode gt The ALT indicator lights 2 Press the menu key E gt The main menu appears full screen on monitor A Select the System settings menu and then the Quick install submenu Navigating Use the arrow keys to move through a menu or list e Use the select key to select a submenu or item
71. press to freeze playback picture press for longer than one second to protect recordings or archive them to a DVD or CD in live mode press to resume playback from the last used playback position in pause mode press to resume playback in live mode press to start playback from one minute earlier in playback mode press to speed up the playback rate in pause mode press to step forward one frame EN 3 4 1 16 ACK key Multiscreen key ALT key Camera keys press when flashing to acknowledge an alarm press to see different monitor display layouts switches the front panel keys between a normal function and an alternate function shown below the key press for longer than one second to get on screen help press to see a full screen display of the camera s picture in the menu mode press to select the camera or enter a password press current camera key to switch the display of the ATM POS data on and off Bosch Security Systems Divar Installation Manual Operating instructions EN 3 5 Alternate functions light below ALT key is lit Fl key restores defaults in active menu F2 key is assigned a specific function in some submenus Arrow keys move around through menu items or values Left Up Down Right Select key selects a submenu or menu item or saves selections made in menus ESC key press to return to previous level or to exit menu syst
72. primary monitor for multiscreen monitoring monitor A s A second monitor for spot alarm monitoring monitor B Cameras with 1 Vpp composite video outputs 75 ohm BNC connectors and video coaxial cable for connecting the video signals AC power supply outlet for the unit that allows for secure isolation The unit has no on off switch for security reasons A keyboard KBD Digital PC for Control Center and Configuration Tool applications Pan tilt zoom control units Bosch D9000 series control panels SCSI cable for connection to external storage devices External storage devices DVAD LP Storage Array or DVAS RAID Storage Array Video Manager for system expansion ATM POS bridge for connecting ATM POS devices Bosch Security Systems external DVD writer for local archiving for Divars without internal writer The following points should be taken into consideration when using the internal DVD writer The DVD writer might not support all CD and DVD media For a list of approved CD and DVD media not supplied by Bosch please visit www boschsecuritysystems com After making an archive with the DVD writer we advise you to test the CD or DVD media to verify that the archived data can be played back on a PC To update the Archive Player software that is written to a CD DVD when a local archive is made insert the supplied CD into the DVD writer The Divar automatically detects new Archive Player software Follow the instructi
73. r and the video loss and indicators switch off after the dwell time but the alarm still needs to be acknowledged If auto acknowledge is enabled the beeper and the video loss and indicators switch off after the dwell time EN 3 14 Multiple alarms Monitor A switches to multiscreen view if more than one alarm occurs The latest alarm status message is always shown Pressing the acknowledge key deactivates all alarms Disk full alarm A disk full alarm message is displayed on monitor A and the alarm beeper sounds 1 Press the acknowledge key to acknowledge the disk full alarm gt The beeper is silent gt The disk full alert message disappears 2 To avoid losing information take corrective action to free disk space for example archive and delete some recordings Bosch Security Systems Divar Installation Manual Hardware setup EN 4 1 CHAPTER 4 Hardware setup This chapter contains detailed information about the connection of external equipment to the unit The connector types and their pin signals are described All the connectors are located at the rear panel of the unit Bosch Security Systems Divar Installation Manual Hardware setup Rack mounting The Divar can be mounted in a 19 inch rack A rack mounting kit is supplied with the unit that includes e left and right rack mount ears e four Torx screws with integrated lock washers e a Torx screwdriver Moun
74. r playback of secure video files Additionally Bosch Security Systems Divar Installation Manual Introduction a web browser on a PC can be used to view live images or playback recordings from a Divar The PC based Configuration Tool facilitates the setup of the unit ATM POS transaction data can be recorded and viewed if the Divar is connected to an ATM or POS device via an ATM POS bridge unit and has a license installed Looping auto terminating video inputs video outputs alarm inputs and outputs and remote control connectors are on the rear panel The two monitor outputs provide CVBS video signals in either NTSC or PAL Monitor A displays full screen or multiscreen digital pictures that can be frozen and zoomed Monitor B displays live full screen pictures Versions There are various Divar models 6 channel 9 channel and 16 channel each with various storage capacities In addition a Divar can have one or both of the following e An internal DVD writer Bilinx enabled camera inputs A Divar with an internal DVD writer allows you to make archives locally without the need for a PC The writer supports DVD RW DVD R CD R and CD RW media A Divar Bilinx supports the use of Bilinx cameras Bilinx technology embeds control commands in the video signal enabling direct camera access and control through a single video coaxial cable This manual describes the 16 channel version with an internal DVD writer and Bilinx e
75. rts ATM POS devices external bridge required Bosch Security Systems Divar Installation Manual Introduction On screen help On screen context sensitive help is available for all topics Just press the yellow ALT key for at least one second to see the help text associated with your current activity Press the escape key to exit help For more information please visit www boschsecuritysystems com Unpacking Check the package for visible damage If any items appear to have been damaged in shipment notify the shipping company Unpack carefully This is electronic equipment and should be handled with care to prevent damage to the unit Do not attempt to use the unit if any components are damaged If any items are missing notify your Customer Service Representative or Bosch Security Systems Sales Representative The shipping carton is the safest container in which to transport the unit Save it and all packing materials for future use If the unit must be returned use the original packing materials Package contents Check for the following items Digital Video Recorder Divar 16 Divar 9 or Divar 6 unit Quick reference guide e Divar operation manual Divar Control Center and Archive Player operation manual e Installation manual this manual EN 1 3 e A 25 pin D type connector board with screw terminals used for switching and alarm connections A 15 pin D type connector board wit
76. s several indicators and requires that the user acknowledges the alarm situation The unit can react to an event in any one of the following ways Alarms A beeper sounds e A status message is displayed e An alarm icon is displayed The border around a cameo can change color e An alarm indicator ZN EX or flashes The indicator flashes An output relay is activated Alarms and Triggers The view modes on the monitors change A controllable camera is moved to a pre defined position e Recording speed changes The unit changes the way it operates via pre defined profiles EN 3 12 Background events Triggers and alarms can change background tasks that you as user may not even notice Unit responses that are not visible to the user are for example a change in recording speed the activation of the output relay and event logging The unit can also be configured to record and automatically protect video clips upon the activation of an alarm input A trigger may change the way the camera images are displayed on the monitors without requiring your intervention Bosch Security Systems Divar Installation Manual Operating instructions Alarm inputs If an input causes an alarm e Monitors A and B can switch to a pre programmed view mode e Monitor A The border around the displayed cameos is red The alarm icon is displayed in each cameo An alarm status message is displayed e Monitor B Sequen
77. s used to set up and store the dynamic characteristics of the unit Setting the dynamic characteristics The settings in the Profiles menu provide the opportunity to tap the powerful functionality of the unit By spending some time in planning and setting up the six profiles available you can provide efficient use of resources while maintaining effective cover for most types of working situations Profiles are usually based on a calendar switching on and off at a particular date or time for example weekends or night Profiles can also be switched by an input signal based on an external switch or armed alarm system EN 5 2 A profile determines how a unit behaves when that profile is active Unit behavior includes how events are handled It also defines recording rates both under normal conditions and in response to input and motion events Unit behavior can be set up differently for each of the six profiles Profiles can be named and copied to facilitate their setup and management Accessing the menu from the unit To open the menu 1 Press the ALT key to enter the alternate function mode gt The ALT indicator lights 2 Press the menu key gt The main menu appears full screen on monitor A Navigating Use the arrow keys to move through a menu or list e Use the select key EJ to select a submenu or item Use the escape key to go back Access to some menu items can be password protected Bosch S
78. t in a risk of fire or electric shock 18 Object and Liquid Entry Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the unit 19 Replacement Parts When replacement parts are required be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards EN v 20 Safety Check Upon completion of any service or repairs to this unit ask the service technician to perform safety checks to determine that the unit is in proper operating condition 21 Coax Grounding If an outside cable system is connected to the unit be sure the cable system is grounded U S A models only Section 810 of the National Electrical Code ANSI NFPA No 70 1981 provides information with respect to proper grounding of the mount and supporting structure grounding of the coax to a discharge unit size of grounding conductors location of discharge unit connection to grounding electrodes and requirements for the grounding electrode CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Bosch Security Systems Divar Installation Manual EN
79. t of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer Bosch Security Systems Divar Installation Manual 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this unit during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moistue does not operate normally or has been dropped 15 Moving Disconnect the power before moving the unit The unit should be moved with care Excessive force or shock may result in damage to the unit and the hard disk drives 16 Power Sources This unit should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supply you plan to use consult your appliance dealer or local power company 17 Overloading Do not overload outlets and extension cords as this can resul
80. tage resistive 30 Vac 40 Vdc max Carrying power External I O 25 pole D type socket Signal name Description Alarm_in_1 1 Alarm input 1 Alarm_in_2 2 Alarm input 2 Alarm_in_3 3 Alarm input 3 Alarm_in_4 4 Alarm input 4 Alarm_in_5 5 Alarm input 5 Bosch Security Systems Divar Installation Manual Hardware setup Signal name Description Alarm_in_6 6 Alarm input 6 Alarm_in_7 7 Alarm input 7 Alarm_in_8 8 Alarm input 8 Alarm_in_9 9 Alarm input 9 Alarm_in_10 10 Alarm input 10 Alarm_in_11 11 Alarm input 11 Alarm_in_12 12 Alarm input 12 Alarm_in_13 13 Alarm input 13 Alarm_in_14 14 Alarm input 14 Alarm_in_15 15 Alarm input 15 Alarm_in_16 16 Alarm input 16 Relay1_A 17 Relay 1 output pole 1 Relay1_B 18 Relay 1 output pole 2 Relay2_A 19 Relay 2 output pole 1 Relay2_B 20 Relay 2 output pole 2 Relay3_A 21 Relay 3 output pole 1 Relay3_B 22 Relay 3 output pole 2 Relay4_A 23 Relay 4 output pole 1 Relay4_B 24 Relay 4 output pole 2 System Ground 25 Chassis Ground EN 4 8 SCSI connection The unit provides a 50 pin high density SCSI 2 port for connection of an external storage system for example a LP DVAD or a RAID DVAS storage array To use this feature connect the drive s SCSI cable to the SCSI 2 connector on the rear panel The Divar with internal DVD writer is delivered with a terminator connected to
81. terature accompanying the appliance WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE AND OBJECTS WITH LIQUIDS SUCH AS VASES SHOULD NOT BE PLACED ON THIS APPARATUS plo Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Power Disconnect Units have power supplied whenever the power cord is inserted into the power source The power cord is the main power disconnect for all units The socket outlet shall be installed near the equipment and shall be easily accessible IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions 2 Keep these instructions 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider that the other A grounding type plug has two blades and a third grounding prong The wide blade or third prong are provided for your safety If the provided plug does not fit into the outlet consult an electrician for replacemen
82. the SCSI connector Do not remove the supplied terminator from the SCSI connector unless you connect a disk array The default SCSI ID of the Divar is 7 The SCSI ID of the internal DVD writer is 6 If you are using a disk array make sure that the ID you select is different from these IDs Adding additional storage arrays deletes all existing data Specification Connector type 50 pin narrow SCSI connector for external SCSI device Bus format Narrow 8 Bits single ended Max number of SCSI devices 6 7 when Divar has no internal DVD writer Max transfer rate 20 Mbytes per second Total max cable length Fast 20 2 to 4 SCSI devices 3m uniformly spaced 5 to 6 7 SCSI devices 1 5m uniformly spaced The internal SCSI cable length is approximately 17 cm This must be taken into account when calculating the total cable length Panel view Bosch Security Systems Divar Installation Manual Hardware setup Power Supply Power is supplied to the unit via the IEC style socket The unit has no on off switch for security reasons This means that the unit is always powered as long as the power cable is connected from the unit to a live power socket Specifications Input Voltage 100 240 Vac 10 Current 0 7A 0 3A Input Frequency 50 60 Hz Power supply socket un Pin no Description name LIVE 1 AC live NEUTRAL AC neutral PE 3 Protective Earth Panel view Testing In Li
83. ting 1 Remove the four Torx screws two on each side located near the front panel on the right and left side of the housing 2 Attach the mounting ears to each side ensuring that the lip is under the unit Use the four Torx screws with lock washers and tighten securely 3 Install the unit into the rack using the rack manufacturer s supplied hardware When installing the assembly into the rack be careful not to restrict airflow around the vent holes located in the side panels or to exceed the recommended operating temperature EN 4 2 Camera connections Connect cameras to the unit using 75 ohm video coaxial cables with BNC connectors There are two BNC connectors for each camera Either connector can receive a camera s signal This signal is looped through directly connected to the other connector so that you can send the camera s signal to other equipment The camera input connectors are auto terminating so you do not need to add a terminator to the output connector if no additional equipment is connected If the camera signal is looped through to additional equipment make sure that the end of the video line is terminated with a 75 ohm termination The Divar automatically configures itself as a PAL or NTSC unit The unit determines the standard by detecting the signal format of the first connected camera lowest camera input number Cameras that support the Bilinx communications standard can be directly conne
84. tion for impedance matching Indicators ACT 10 100 Bosch Security Systems Divar Installation Manual Hardware setup Control port The control port is a bi phase port for connecting the control units of controllable cameras Five bi phase outputs are provided for dome camera and pan tilt and zoom control The screw terminal connection board supplied with the unit simplifies all bi phase connections to the unit O O O O O O O O Q Q Panel view EN 4 6 Specifications 128 Ohm 30V max Output impedence Overvoltage protection Differential voltage amplitude 1V min 2V max with a characteristic load of 220 Ohms connected across the differential output 1 5 Kilometers max Belden 8760 Number of loads per output 4 max Cable length Recommended cable Control port 15 pole D type socket Signal name Description Code 1 1 Bi phase control ch 1 minus Code 1 2 Bi phase control ch 1 plus Shield 3 System ground cable shield Code 2 4 Bi phase control ch 2 minus Code 2 5 Bi phase control ch 2 plus Shield 6 System ground cable shield Code 3 7 Bi phase control ch 3 minus Code 3 8 Bi phase control ch 3 plus Shield 9 System ground cable shield Code 4 10 Bi phase control ch 4 minus Code 4 11 Bi phase control ch 4 plus Shield 12 System ground cable shield Code 5 13 Bi phase control ch 5 minus Code 5
85. ui aa eE ees 3 11 Alarm in p t Sia acon ns ee pe Sea eee er 3 12 Motion alarm a a o aa T En aoan ET 3 12 Video loss alarm 0 0 i a a i a e aaa Aaaa WaT 3 13 Multiple darse 3 13 Disk f ll alarn ne ee aa 3 13 Hardware Soup creta ua 4 1 Rack MOUIN u a se ee a en Biene a Bien en 4 2 Camera connections 222222 een een nenne een nennen 4 2 Monitor connections 22ue2 seen nennen nenn nern nen 4 3 Bosch Security Systems Divar Installation Manual EN iii Console port connection 0 0 c cece teeta 4 3 Keyboard Connections ks ierse nnii eens 4 4 Ethernet connection 6 eens 4 5 Control Ports ae Ae Seite Er ea i Re te ihe ee 4 6 External I O connection 2 222222 een een een nn 4 7 DO CSIGONNMECTION Er ee A Bra Ge ee AS eu 4 8 Power Supply ur ana dled ida hip as 4 9 TESI r ee a he dat eld ad ena ai a tae AS 4 9 M intenahce au reelle 4 9 Menl systenis se 2m acia Da 5 1 Overview of the menu system 0 eee 5 2 Accessing the menu from the unit 0 0 ccc eee 5 2 Man MON Ut ats tied eee Meek a peek SR Qed alg lesa 5 3 Histan naua ee ee eu Be 5 4 Piston EINER y sat dee Ass ee ee oi lei aude heute Ai 5 4 Pistor Eist a a A crates Serene ease 5 4 Disk manager res o un E an nn wera ie 5 4 Status Overview 0 cece eee eee nenn 5 4 LOCaliarGhivin Gs fas cet Sui AR A ANS A DE Ne 5 5 Protected Recordings ocoooocccoccccnnc Ea a a A 5 5 Authenticity Check 0 00 ees
86. ve mode select full screen display for each camera and check the picture quality If the quality is poor check The BNC connections Loop through terminations Video levels of incoming signals and the possibility of ground loops Record for at least three minutes at the highest recording speed Then play back the recording selecting each camera for full screen display in turn Check the playback picture quality Check to see whether the programmed quality setting is adequate Maintenance Maintenance of this unit is limited to external cleaning and inspection Refer all servicing to qualified personnel WARNING Do not open the top cover or attempt to service the unit as this may expose you to dangerous voltages and other hazards Opening the unit will void the warranty Bosch Security Systems Divar Installation Manual Hardware setup EN 4 10 Bosch Security Systems Divar Installation Manual Menu system EN 5 1 CHAPTER 5 Menu system You access all the parameters used to set up the unit via the menu system The large number of parameters available gives you the opportunity to program an extensive functionality There are two ways of accessing the menu system via the keys on the front of the unit itself or via the PC based Configuration Tool application Using the keys on the unit has the advantage of not requiring a PC and is the recommended method if you are using the unit in a
87. ve to an exception entry and press the select key to start editing Enter the start date time the duration and the profile name Press the F2 key to empty an entry gt gt PROFILE OVERRIDE Select a different profile to manually override the active profile for a temporary period Set the duration for which you wish to override the active profile The maximum is 24 hours If set to Always the calendar is disabled completely If set to zero the override function is disabled gt gt PROFILE MANAGER The Profile Manager lists the scheduled and active profiles The Profile Override Inputs submenu sets up the inputs to switch profiles The Profiles Titles submenu assigns names to the six different profiles The Camera Pre position on Profile Change submenu sets four controllable cameras to a specified pre position when the active profile is changed to a different profile EN 5 14 gt gt gt Profile override inputs Six inputs can be set up to select a profile e The active profile defined by the calendar and exception day schedule is overridden by the input selection as long as the input is active Inputs used for other purposes cannot be used to select a profile An entry is set to empty by selecting it and pressing F2 gt gt gt Profile titles e Select a profile Enter up to 4 characters to give a meaningful name to the profile gt gt gt Camera pre position on profile change e Four