Home
Bogen CG8A Stereo System User Manual
Contents
1. Low battery under 10 remaining Very low battery under 5 remaining On the gain screen this row will not show battery information instead having a row of digital gain knobs that will match the gain shown in the meters above them O Gain knob 2 It might take a few minutes for the charge symbol to appear after a microphone was placed in the charger revo aos 30 Front Panel Menu Tree The menu tree is navigated by using the Right button to enter a menu the Left button to leave a menu and the Up and Down buttons to scroll between the options in the menu With the Enter button a menu entry is selected if itis a sub menu the submenu will open if it is a check box this will either check or un check the option and if it is a selection radio button it will select that value If it is a value entry it enables the Up and Down buttons to change the value Pressing enter again in that case will store the value and leave the data entry mode Main Menu Home screens RF Screen Main Menu l VU Screen Gain Screen 2 3 A System Info system Settings Audio Settings Microphone Management screen Contrast Reboot In the main menu the first five options are sub menus that are described below The fifth entry Screen Contrast controls the contrast of the front panel when selected and the sixth entry Reboot reboots the system
2. a External Mute IP Address Port 7 Biamp Nexia Username Biamp Tesira Password Clearone Converge lnteract Pro Clearone XAF Polycom Soundstructure Select the Connection Mode used to communicate to the external system If Serial connection is selected select the baud rate from the opening window To set up connection to a Control System the Elite can either be the Server or the Client If Telnet is selected and the Executive Elite system is a client the IP Address login information and port number of the Control System Server must be entered revo abs 56 Administration The Administration menu allows administrator level system control Under Logging system logs can be downloaded for advanced system information The dropdown menu can be used to choose the minimum severity logging level of the messages that will be retrieved Below that system configuration settings can be exported and imported Importing a configuration will overwrite all currently active settings in this Executive Elite System Export and Import can be used to easily duplicate settings from one Executive Elite Base DSP to another Log Level Debug v Download Logs Restart Base Digital Signal Processing Unit Restart i Restart Import Export Configuration Restart Remote Antenna Receiver es Export Configuration into an XML file Export Restart All Microphones Restart Import Configuration from an XML file Imp
3. revo abs 13 Components Depending on which system you ve purchased your Revolabs Executive Elite System package contains the following e Rack mountable 4 or 8 channel Base DSP Unit e Remote Antenna receiver unit with mounting plate e 4or 8 Microphone Charger Base with external Power Supply e Power cable USB cable network cable e Euroblock connectors e Documentation In addition you might have bought one or more Revolabs Elite wireless microphones Each microphone package will include e Revolabs Elite wireless microphone different styles e Lanyard and over the ear speaker element wearable microphone only e Batteries e Documentation The Executive Elite Base DSP unit contains all the logic required to support the audio signal from the microphones in the different output formats analog audio digital audio over AVB It supports the management interfaces front panel local web UI room control system UI as well as communication with the remote cloud based UI The Remote Antenna receiver contains all components required to receive and send audio signals from and to the microphones It includes the required diversity antennas The remote antenna also controls over the air synchronization between systems and provides the scan of the RF frequency to determine how many additional microphones might be used in the area The remote antenna receiver communicates with the Elite Base DSP unit using a direct IP
4. revolabs 31 System Information The first option in the Main Menu is System Information System Information offers information on the Base DSP unit the Remote Antenna Receiver the Microphones and the available network connections None of the information in this menu and the submenus can be changed Base Information 1 FW Version 2 Product Version 3 System Name 4 Product Name System Info Antenna Information Mice 1 Information Base Information A mays ee l Mic 1 Type l i 2 Mic 1 Version Antenna 3 FW Version 3 Mic 1ID Information Microphone Information Microphone Information Network 1 Mic 1 Information Information Network Information LAN 1 IP Address 2 MAC Address 3 Subnet A 8 Mic 8 Information DHCP enabled disabled Gateway DNS Server 1 DNS Server 2 Network Information Network Information LAN Network Information USB Network Information Network Information AVB USB 1 IP Address 2 MAC Address Network Information AVB 1 MAC Address 2 Link Status 3 PTP Mode 4 Master MAC Base Information provides information on the current firmware running on the base DSP unit the product version product name and system name The Antenna Version menu indicates whether the link to the antenna is up or down shows the Mac address of the remote antenna and lists the Firmware version of the software running on the Remote antenna In the Microphone Information submenu pair
5. 115200 IP Address Password Preamp Gain XLR style microphones Input Signal Trim Of 30 75 ft None f f Off 1 8 Telnet 115200 lt lt empty gt gt lt lt empty gt gt lt lt empty gt gt lt lt empty gt gt keeps previous value On 15 O dB O dB J O on Cc ya 60 revoCloud Access To use an Executive Elite through the Cloud Server it first needs to be registered If registration was not completed during the Initial Setup it can be registered through the Online Access page Register System lor Online Access x Ta register ihis gratem for online access pitaso anier ihe amai aderess Create lew Ailenin md Cascheord bor the onde itou you hase piiga Sol ug Email Address Password Fao Password Register How Cancel An unregistered Elite s revoCloud Access page takes the same appearance as the registration request page in the Initial Setup wizard Selecting cancel on the popup navigates back to the Monitor page For a system registered to the Cloud Server revoCloud Access will lead to a Cloud Server permissions page instead of the registration page The Cloud Server permission page lists the account the system is registered to and allows enabling or disabling online access Be revolahs Online Access Maine Conference room System 3 T Rogestered to rewodivevolaibs com Enable Onime Access Da aii To take advantage of the cloud web UI a system needs to be register
6. Executive Elite Base DSP Unit The main processing unit of the Executive Elite system The Base DSP unit transforms the encrypted audio signal from the microphones into unencrypted analog or digital audio and applies audio control All management of an Executive Elite system is done through the Base DSP unit Firmware The software running on all components Software required for functionality Linking microphone A microphone that was previously paired to an Executive Elite System will attempt to link to the same system when it is switched on or removed from a charger Linked microphones actively communicate with the Executive Elite System Microphone and Executive Elite Remote Antenna dynamically negotiate an available frequency and time slot for their communication Omni directional Microphone A microphone that receives audio from all directions 360 degrees Pairing microphone Setting up communication between a microphone and an Executive Elite Base DSP unit revolans 12 Remote Antenna The external transmission and reception device for the Executive Elite System The remote Antenna is connected to the Executive Elite Base DSP unit using a point to point Cat 5e or Cat 6 connection User Interface UI An interactive display allowing product users to control the Executive Elite system The Executive Elite offers several User Interfaces including a Web UI a Front Panel UI and the Cloud Management UI
7. hover over the desired microphone s column and a black on white arrow button will appear in the upper right corner Clicking the arrow opens the microphone control menu allowing access to the following options e Unpair Mic The selected microphone will be unpaired from the Elite Base Unit The microphone will not relink if turned back on e Restart Mic The selected microphone turns off and reboots relinking after it turns back on e Enter Standby Leave Standby All microphones in the same group as the selected microphone will enter standby mode In this mode the microphone will show a single Yellow blink every 10 seconds Standby mode uses minimal power and can be turned off by touching the microphone s mute or selecting Leave Standby in the microphone control dropdown e Power down Mic The selected microphone is powered off but not unpaired Turning the microphone back on will cause it to relink revo aos 43 Microphone Audio Page fevolad MONITOR MICROPHONE AUDIO Maine Conf Room System 3 View by Group Mic Manage Groups Restore to Default Table group Panel table Lectern Presenter MIC TYPE Omni XLR Directional Directional Mini XLR Mini XLR Wearable STATUS On On Not Paired Pair On On On On On Trim Preamp Trim Trim Trim Preamp Trim Preamp Trim Trim INPUT me E ae 3 gt v 20 9 U 0 209 ge 20 o 0 SIGNAL a E 1 C C 10 10 Cc C 10 i 1 10 i
8. lt output gain gt val outputlevel ch lt channel number gt lt O 1 gt 72 preampgain get preampgain ch Retrieve the given val preampgain ch lt channel number gt channel s preamp gain lt channel number gt lt preamp gain gt preampgain set preampgain ch Configure the given val preampgain ch lt channel number gt channel s preamp gain lt channel number gt lt preamp gain gt preamp gain range 20 lt preamp gain gt to O dB pushtotalk get pushtotalk lt group Retrieve group push to val pushtotalk name gt talk setting value lt group name gt lt 0 1 gt 1 push to talk set O not set pushtotalk set pushtotalk lt group Configure group push val pushtotalk name gt lt 0 1 2 gt to talk setting lt group name gt 1 push to talk set lt O 1 2 gt O not set 2 toggle pushtotalkmic get pushtotalkmic ch Retrieve microphone s val pushtotalkmic ch lt channel number gt push to talk state lt channel gt lt 0 1 gt 1 push to talk set O not set shutdownmic shutdownmic ch Power the microphone shutdownmic ch lt channel number gt off lt channel number gt tabletopmutegroup get Retrieve the given val tabletopmutegroup group s tabletop mute tabletopmutegroup lt group name gt state lt group name gt lt 0 1 gt O not tabletop mute 1 tabletop mute tabletopmutegroup set Configure the given val tabletopmutegroup group s tabletop mute tabletopmutegroup lt group name gt lt 0 1 gt sta
9. Pee revo abs 55 microphones can be from the base but the more impact the broadcast will have on other RF devices in the vicinity The different RF power settings provide suggested ranges in feet and meters for the maximum distance between the remote antenna and the microphones While distances are provided in the setting obstructions in a room do impact the maximum possible distance Please keep that in mind when selecting a RF power level and testing connectivity Automatic Power Scaling allows a microphone to detect the RF power coming from the antenna and modify its own output This way a microphone closer to the antenna can reduce its RF impact by limiting the RF signal Automatic Power Scaling should be enabled in installations that require high transmit power settings long distances and include multiple Executive Elite Systems We recommend experimenting with several different RF settings to find the best one for your RF needs External Control Configuration The External Control menu enables aspects of the Executive Elite to be controlled through a room control system or supported external DSPs When connected to an external DSP the Elite can grant that device control over the mute and unmute status of its audio Supported external DSPs can be selected from the external Mute drop down as shown below Processor Control System Connection Mode Seral RS 232 Telnet None Control System Biamp Audio
10. adapters third party microphone elements are provided by the customer The pre gain stage is provided to enable greater control over leveling the analog signal of these microphones for highest signal levels without clipping Please ensure that signals are correctly set based on the microphone elements used with these adapters revo abs 44 Filters High Pass and Low Pass filters are provided to adjust to room and application requirements Use the High Pass filter in rooms that have a high background noise in the low frequencies air conditioning lighting fixtures etc The Low Pass filter allows limiting high frequencies based on the applications used All filters are bi quad filters reducing the signal by 6dB per octave EQ The EQ works in four bands Start Frequency Center Frequenc End Frequenc Low 100 Hz 150 Hz 250 Hz Low mid 250 Hz 489 Hz 1 000 Hz 1 000 Hz 1 739 Hz 3 000 Hz Hi 3 000 Hz 4 450 Hz 6 000 Hz Gain adjustment is up to 10dB around the center frequency within the band with drop off to OdB adjustment at the border frequencies Analog Output When selecting Analog Output the VU meter shows the audio signal as provided to the analog ports The final gain stage provided here allows gain or trim to be applied to the signal before it leaves the Executive Elite Base unit Line level output provides the signal with an additional 20dB gain compared to the Mic level output Digi
11. Charger Base The microphone will automatically turn on Based on settings in the Base DSP the microphone will start either un muted or muted indicated by green or red blinking lights respectively 2 Gooseneck Tabletop microphones should be located on the table with the microphone pointing toward the user trying to keep the microphone 18 to 24 inches 45 to 60 cm from the speaker The pick up pattern for this directional microphone is cardioid focusing a beam towards the speaker It is always better for the microphone to be as close to the person speaking as possible but avoid placing the microphone where it might be blocked by equipment or paperwork Avoid placing microphones too close to an audio or video conference speaker to avoid echoes Make sure that the microphone is always placed standing on its rubber feet atop a flat surface Refer to the diagram below 3 With the microphone in position on the table see the picture above for example mute or un mute the microphone by touching the mute area confirm by flashing green or flashing red LEDs respectively In push to talk mode touch the mute area and keep the finger there to unmute the microphone Removing the finger from the touch area will mute the microphone again 4 To turn the microphone off return it to the Charger Tray or touch and hold the Mute touch area for about 10 seconds until the LEDs turn solid red and remove the finger The microphone can also be turn
12. Directive 2011 65 EU Model Number Description 03 ELITEEXEC4 EU Executive Elite System 4 Channel w o microphones 03 ELITEEXEC8 EU Executive Elite System 8 Channel w o microphones 03 ELITEMIC OM EU Elite Microphone Omni directional Tabletop 03 ELITEMIC DR EU Elite Microphone Uni directional Tabletop 03 ELITEMIC GN6 EU Elite Microphone 6 Inch Gooseneck Tabletop O03 ELITEMIC GN12 EU Elite Microphone 12 Inch Gooseneck Tabletop 03 ELITEMIC WR EU Elite Microphone Wearable 03 ELITEMIC XLR EU Elite Microphone XLR microphone adapter 03 ELITEMIC TA4 EU Elite Microphone TA4 microphone adapter Any unauthorized modification of the products voids this Declaration For a copy of the original signed declaration of conformity please contact Revolabs at the above address Pee revolabs WEEE Notification The Waste Electrical and Electronic Equipment WEEE directive 2012 19 EU is intended to promote recycling of electrical and electronic equipment and their components at end of life According to the requirement of the WEEE legislation the following user information is provided to customers for all branded Revolabs products subject to the WEEE directive The symbol on the product or its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over toa designated collection point for the recycling of was
13. Elite system provides three means to synchronize systems the Sync Bus the AVB network and Over the Air synchronization Microphone Density and Radio Frequency Interference Synchronizing Executive Elite systems is important to maximize the density of microphones that can be supported in one area Non synchronized systems in the same space block a higher number of radio frequency channels than the number of microphones they support causing RF loss and audio drop outs It is therefore important to synchronize all Executive Elite systems that are in proximity with each other to limit the number of potential audio issues There is no disadvantage in synchronizing systems that are not in close proximity Synchronization only affects the internal clocks of systems not the channel selection they make for their microphones It is therefore better to error on the safe side and synchronize even systems not expected to be in direct proximity Maximum Density of microphones in one area is affected by the selected audio quality and whether back channel audio to the microphones is enabled or not It is also dependent on other wireless radio frequency traffic in the vicinity and whether that traffic is synchronized or not Selecting the right RF power setting is important to limit the area in which RF traffic of a microphone and receiver is being seen to the coverage area therefore reducing interference with adjacent areas See later user interface sections fo
14. a different cluster simply enter the name of that cluster in the field An Executive Elite base DSP can only be part of one cluster at a time B revo aos 5 To reset the system password used on the front panel user interface and the local web interface enter the new password in the password field and confirm it in the confirm password field before saving The password needs to be numeric and has a minimum length of 4 digits The Enable Telnet Server setting will enable or disable telnet access to the Base Please note that if this setting is set to Off the Telnet option for servers on the External Control Page will not function Selecting Base Pairing Lock will disable the pairing functionality from the system s front panel Even if Base Pairing is not locked the front panel requires the password before allowing pairing of microphones In installations where several Executive Elite systems are in proximity the systems need to be synchronized to allow for best usage of the RF space and highest number of active microphones at the same time The System Clock section sets up and controls synchronization Clock Source allows a user to specify which transport is used for the synchronization Local means that the system is a stand alone system not synchronizing with any other system Serial means that the 3 wire bus is used for synchronization between different systems AVB indicates that the AVB network is used for syn
15. active linked A linked microphone may be shut down remotely by selecting Turn off If no microphone was paired to the selected channel the menu will only offer the pairing option revolabs 36 Local Web UI The local Web UI allows managing an Executive Elite base DSP unit through a web browser The local web UI can be accessed either through the IP network if the Executive Elite base DSP unit is connected to the LAN using an Ethernet cable or through the USB connector in the front of the base DSP unit Running the local web UI requires Java to be installed on the computer that is opening the browser page NOTE Supported web browsers are Microsoft Internet Explorer Google Chrome and Mozilla Firefox Connecting to the local web UI When connecting a Computer for the first time using the USB interface the PC may need to install driver software to enable web access through the USB port This installation could take several minutes During this time an installation message like this might be shown on the Computer 3 Driver Software Installation Installing device driver software RNDIS Ethernet Gadget Installing driwer software NOTE If you do not see this or a similar message the driver may not have been successfully installed If this occurs connection to the web interface of the Executive Elite System cannot be established through the USB port This is likely due to your computer s driver update c
16. against the snap while carefully pulling the Antenna Receiver forward until the Antenna Receiver releases from the snap The Remote Antenna Receiver housing can now be detached from the wall plate E revo abs 20 Connect Remote Antenna Receiver to Base DSP Unit Connect the Remote Antenna Receiver with the Antenna output of the Base DSP Unit using a CAT 5e or Cat 6 cable NOTE This needs to be a point to point connection between the two units This is a time crucial connection Routing this connection through a switch will fail The Antenna output of the Base DSP unit provides Power over Ethernet which is required to power the Remote Antenna Before connecting the network cable ferrite beads need to be installed on either end of the cable to minimize electro magnetic interference One ferrite bead should be attached 4 of an inch 7 10 millimeters from the end of the cable that will connect to the Base DSP unit The second ferrite bead needs to be attached 5 inches 13 centimeters from the end of the cable that will attach to the antenna NOTE The Antenna Receiver provides room for the ferrite to be placed in the antenna casing underneath the mount plate If running the cable through the Network Cable Opening in the mount plate the ferrite must be installed after the cable has been pulled through Otherwise it will not fit through the opening 5 in 1 4 3 8 in ae om 7 10mm i B Ze _ Antenna ase re
17. chairman mute settings for the group will automatically change to Individual Mute and Unmute at Startup These settings can be changed afterwards if required Only one chairman microphone may exist in any one group Setting another microphone in the group as chairman will revoke the previous chairman s rights and transfer it to the new chairman microphone Similarly only one chairman can be active in groups shared across a Cluster If a chairman is located on another base in the cluster it will be listed next to the Chairman icon in the active group header followed by lt its Elite MAC Address gt revo aos 48 System Audio Settings The System Audio Settings Page allows selecting the audio compression in the system as well as selecting back channel audio and the source for the back channel audio Mic Audio Legacy Mode On Off None Back Channel Audio Max Microphones 32 Channel i Source wall Microphone audio can either be Standard definition SD or High Definition HD HD audio provides double the bit rate for audio transfer over the wireless link per microphone Back channel audio is audio delivered to a wearable microphone or TA4 adapter If back channel audio is selected it will be of the same audio format as the microphone audio In applications where the back channel audio is not required it can be switched off allowing the RF space to be used more efficiently and increase the maximu
18. connection Cat 5e or Cat 6 cable The Charger Base stores and charges the wireless Elite microphones when not in use Communication capabilities are not required for the charger tray because all information transferred between microphones and the Elite base DSP unit passes over the wireless connection This includes pairing of microphones to receivers firmware updates of microphones and commands sent to the microphones revoaos 14 Revolabs Elite wireless microphone systems are designed to work with other audio equipment typically found in an installation This equipment is typically used for Audio Mixing Acoustic echo cancellation AEC Feedback elimination Level control Equalization Noise cancellation The Revolabs Elite system provides some of these features as well It is rec ommended to use either external or Revolabs audio control systems to change settings and adapt the audio to your exact needs Best audio quality is easier to attain when only one system is used to adapt the audio The Revolabs Elite system is designed to optimize audio capture reproduction by J J Ee providing Consistent audio input from all participants Minimize room noise Mute control Wireless encryption Automatic channel selection Full duplex audio revolabs 15 Revolabs wireless microphones and transceivers receive signals audio commands from the remote antenna receiver while sending audio back
19. correctly before saving changes as otherwise the Executive Elite system will not be accessible through the IP connection NOTE If the network settings are configured incorrectly it can cause the Elite to become disconnected from the network making access to the Web UI over the LAN impossible even to fix the network configuration settings However the Web UI can still be accessed from the USB port on the front panel of the Elite Connect your computer with the Executive Elite base s front panel USB port using a micro USB cable If required the operating system will install driver software on your computer After that is complete go into the menu on the Front Panel LCD where a popup should have revo abs 53 appeared giving the static IP Address for the USB connection Open a web browser and enter the IP Address then log into the Web UI Now you may correct any network settings to connect the executive Elite base to your IP network Below the IP information is the USB IP table In this table the Static IP address and the subnet for the USB interface on the front of the Elite base are defined In the upper left is the Network Time Protocol NTP server table List the NTP servers the Elite has access to in this area NOTE The Cloud server requires that the system time on the Executive Elite base DSP is correct If the NTP servers listed here are not reachable for the Pebble system and system time is therefore incorrect ac
20. firmware version running on the system it will also display the base serial number the MAC address of the IP connector and the run time since the last start This page allows remote download of logs from the Executive Elite It also allows unregistering the executive Elite system Account Management l Required Organization Name Revo First Name Last Name Email Address revo revolabs com Password Confirm Password Update Account Cancel J The link to the Manage Account page is in the upper left hand corner of the revoCloud home page On this page user name organization or account name account email and password can all be changed To update any part of this page enter the new information in the field and save the updates to the system Cancel will clear any entered information and return the user to the home page To change the account password enter the new password in both the Password and Confirm Password boxes before choosing the Update Account button Ifthe passwords entered in the two fields are different a warning message is displayed and the password is not changed revo aos 67 Serial Control Processor Room Control Interface The Executive Elite Base DSP is capable of being monitored and controlled via a control system Communication can either be over the serial port of the Executive Elite or over an IP connection If several Executive Elite Base DSPs are part of an inst
21. into the Web UI Now you may correct any network settings so that the Executive Elite base DSP can register with your IP network If installing the driver software fails the IP Address popup does not appear or the USB IP Address Web UI doesn t load then the USB connection may be faulty Try adjusting the wire or try again with a new cable Antenna Symbol Blinking This indicates that the Elite Base DSP Unit and Antenna are not communicating During a firmware update after the base upgraded its firmware this state might persist for up to 10 minutes while antenna firmware is being updated If no update occurred recently ensure that the antenna cable is plugged into the back of the Elite Base Unit and into the Remote Antenna If the cable is connected correctly restart the Remote Antenna from the Administration page of the local Web UI If the Antenna hasn t relinked 2 minutes after the restart command was issues restart the base Technical Support If you are experiencing technical problems or if you have questions about the operation configuration or troubleshooting of any Revolabs product please email support revolabs com or call 1 800 326 1088 j revolabs 100 Specifications Product Dimensions Component Subtype Subcomponent _ Dimensions Weight ala I 2 43 03 x 20 32 x 4 42 cm 2 95 kg einen a 2 8 x 0 8 in 71x21cm ee ee Receiver 17 3 x 17 3 x 5 1 cm 0 45 kg ee ee ee Charging Base 19 8
22. low battery When there is approximately 2 hours of talk time remaining this LED will turn yellow When the LED turns red there is approximately 1 hour of charge remaining 6 Mute button press to mute un mute and pair microphone 7 Clip used to attach microphone to a shirt lapel blouse or lanyard 8 Charging connector connects to the charging pins of the Elite charging tray Revolabs Elite Wearable Microphones turn on when removed from Charger Base To reduce noise while they are being attached we recommend muting the microphone when attaching and detaching it Bie revolabs 78 To use the Elite Wearable Microphone 1 Remove the microphone from the Charger Base 2 Attach the microphone to clothing or to a lanyard positioning the microphone just above the sternum or breastbone within 6 12 inches 15 30cm from the mouth Make sure that the microphone is attached securely The Elite wearable microphone utilizes an omni directional microphone element it is therefore not important that the microphone points up towards the mouth 3 After positioning the microphone based on the mute behavior defined for that microphone un mute and mute it by pressing and releasing the Mute button confirm by a flashing green LED or red LED respectively If the volume is too low mute the microphone relocate it closer to the mouth and unmute it again 4 To turn the microphones off return the microphone unit
23. second microphone is selected to be chairman the first microphone will lose its rights as chairman and the new chairman will gain them When setting a chairman microphone for a group with no chairman that group s mute mode will be automatically changed to Individual Mute and Unmute at Startup will be activated Mute types and Unmute at startup settings can be adjusted after a chairman microphone has been set When pressing the mute area of the chairman microphone all microphones in the group will change between three different states The first state has the chairman microphone unmuted and allows all other microphones in the group to act according to the group s mute type Individual Mute TableTop Mute or Push to Talk When the chairman touches the Mute area the first time all microphones in the group except the chairman microphone will go into a mute state and cannot be unmuted from any of the other microphones in the group Touching the mute area of the chairman revolabs 95 microphone again will put all microphones into mute including the chairman microphone None of the other microphones in the group can unmute at this time Touching the mute area on the chairman microphone a third time will put the group back into the first state again The Web UI allows these three mute states to be activated individually through the Monitor page Mute lock Mute lock allows locking the mute areas on each microphone separately
24. the microphone s mute would but through the Web UI 4 Tabletop Mute Symbol Indicates Tebletop mode 5 Push to Talk Mute Symbol Indicates Push to Talk mode 6 Chairman Mutes All and Members Mute all microphones in the group or mute every microphone besides the chairman 7 Microphone Dropdown Menu Appears when mouse is hovered over the column Click for Microphone menu For a paired microphone the Monitor page provides the type of microphone the current status the battery charge percentage the current audio output level and the strength of the radio signal of the microphone as detected by the remote antenna The Mute Control area provides information on mute group settings and the current mute setting per microphone or per group This area allows changing microphone settings from locking a microphone mute button Bee revo aos 4 to muting and unmuting microphones based on the group settings The microphone symbols reflect the current mute status for each microphone If it is preferable to view microphones in numerical order rather than by group the View By option at the top right of the page will change the view mode Beside this option the Manage Groups button will navigate to the Group Management page also found under the Audio Management menu Both the Monitor and Microphone Audio pages have a microphone control dropdown menu accessible from the microphone tables To open the menu
25. the microphones are placed too far away from the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or farther from the Remote Antenna the connection will be dropped LEDs flash red yellow green yellow and the microphone will mute After 15 seconds the microphone will beep and will continue beeping every 30 seconds to indicating that it is out of range Move the microphone closer to the Remote Antenna and the connection will automatically be re established to its original state and the beeping will cease Otherwise the microphone will continue beeping until it turns off after about 15 minutes revolabs 82 The Elite Directional Wireless Tabletop Boundary Microphones The Elite Directional Wireless Tabletop Boundary Microphone shown below is designed to provide optimum coverage when placed on a conference room table in front of one to three people 1 Mute touch area touch to mute un mute or pair the microphone The directional microphone provides one mute touch area on the edge closest to the speaker 2 Charging connector connects to the charging pins of the Elite charging tray or crossover adapter 3 Battery door latch open the battery door using this latch 4 Rechargeable batteries replace batteries only with NiMH 2000mA rechargeable batteries Non rechargeable batteries or rechargeable batteries of a different type or lower charge might impact performance of the
26. 122 233 1 0 0 344 Firmware is up to date The revoCloud home page lists all Executive Elite systems registered to the account Their system name and status as online or offline will appear at all times When an Elite is online that device s IP Address firmware version and name of the Cluster it belongs to if applicable will all be shown Under status the revoCloud server will report if the current firmware version on each base is up to date and display the progress of upgrades that have been started using the cloud From the Home Page devices can be selected with the checkboxes on the left of the screen All selected devices may be upgraded at the same time by selecting the Upgrade button at the top of the table while unselected devices will be left as they are Clicking on any system name will open the System Information page for that system E revolabs 66 System Information Maine Conf Room System 4 x System Information System Name Maine Conf Room System 4 Status Online Serial Number fx3270001429 Uptime 16 hours 56 minutes MAC Address AC 44 F2 00 24 D0 Firmware Version amp Firmware is up to date Upgrade Firmware to version 1 0 0 344 IP Address 910 134 122 233 Download Logs and Configuration Data Unregister System yi Close The System information page provides additional information on any specific Executive Elite system Beside the IP address of the system cluster information and the
27. C radiation exposure limits set forth for an uncontrolled environment The antenna s used for this equipment must be installed to provide a separation distance of at least eight inches 20 cm from all persons This equipment must not be operated in conjunction with any other antenna This device complies with RF exposure requirements in Industry Canada RSS 102 Issue 4 For Body Worn Operation SAR data information for users in countries that have adopted the SAR limit recommended by the International Commission of Non Ionizing Radiation Protection ICNIRP which is 0 08 W kg averaged over the whole body or 2 00 W kg averaged over ten 10 gram of tissue for example European Union Japan Brazil and New Zealand Professional Installation Recommended This product should be professionally installed j revolabs Notice to Customers in Australia 1 Do not use in areas where there are explosive hazards 2 Do not use in environments where there is a danger of ignition of flammable gasses Restricted use with certain medical devices Hearing Aids Some devices may interfere with some hearing aids In the event of such interference you may want to consult with your hearing aid manufacturer to discuss alternatives Other Medical Devices If you use any other personal medical device consult the manufacturer of your device to determine if it is adequately shielded from RF energy Your physician may be able to assist you in obtaini
28. D visual status for mute un mute and pairing OV Mute button press to mute un mute and pair microphone 7 Charging connector connects to the charging pins of the Elite charging tray 8 XLR connector male XLR connector connecting to dynamic XLR handheld microphones Pee revolabs 87 To use the Elite Wireless XLR Adapter 1 Remove the wireless adapter from the Charger Base 2 Attach a dynamic handheld microphone to the adapter following safety precautions and user information provided with that microphone 3 After positioning the microphone at the distance it will be used at unmute it and go to the Microphone Management page of the Web UI The XLR adapter s column will have a Pre Amp gain setting once the adapter is paired This slider will allow different types of microphones to be integrated with the Executive Elite system Select the highest setting on the pre amp where clipping is not observed to allow for the highest signal to noise ratio 4 Based on the mute behavior defined for the adapter in the local web UI mute or un mute the microphone by pressing the mute button on the adapter confirmed by flashing green or flashing red LEDs respectively In push to talk mode press the mute button and keep the finger there to unmute the microphone Removing the finger from the mute button will mute the microphone again 5 To turn the XLR adapter off return the unit to the Charger Base or pres
29. One red flash 1 5 seconds every 1 5 seconds Microphone paired and system muted ex tabletop mute Solid red Solid red Pairing mode or confirmation of powering down Alternating slow Pairing failed green and red Alternating slow Microphone not paired green and red Alternating red Searching for a connection yellow green yellow or out of radio range The Microphone will try to re establish the link for about 15 minutes and then turn off automatically 2 RED flashes every 2 RED flashes Microphone is upgrading its second every second firmware over the air Groups of five rapid Off Unit is faulty Contact your RED flashes AV service provider for advice One yellow flash Microphone is in Sleep every 10 seconds mode revolabs 93 The charge status LED provides additional information on the current charge level of the microphone batteries The following information is for a microphone that is out of the charger and switched on Yellow flashing Remaining Battery charge lt 20 but more than 10 1 2 hours talk time remaining on wearable XLR adapter TA4 adapter 2 4 hours talk time remaining on tabletop microphones Red flashing Remaining battery charge lt 10 maximum remaining talk time 1 hour on wearable microphone XLR adapter and TA4 adapter maximum 2 hour remaining talk time on tabletop microphones Mute Groups With Executive Elite Revolabs introduces a very flexible way t
30. REVOLABS Executive Elite Wireless Microphone System e Installation and Operation Guide O1 ELITEEXEC8 03 ELITEEXEC4 EU 03 ELITEEXEC8 JP Pee revo abs Models O1 ELITEEXEC4 03 ELITEEXEC8 TW O3 ELITEEXEC4 JP O03 ELITEEXEC8 EU 03 ELITEEXEC4 TW 2014 REVOLABS INC All rights reserved No part of this document may be reproduced in any form or by any means without express written permission from Revolabs Inc Product specifications are subject to change without notice Revolabs Executive Elite Installation and Operation Guide O1 EXECELITEGUIDE EN August 2014 Rev 1 0 5 revo abs Contents CODO ecesece cence tie seca sncee E E 3 BEA GE CNC ClO EN coca oi cone sane nwese een couvecdeanadoussseartadccoadaeieuousnedtroitesscsarenedeseaitadkcon eval enciauisceaveasedaeeivbuentvaresussndinueds 5 Safety anid Gemeral nformati ON snc EE i 6 FCC Notice to WS CS iieeccscasvececesesreccccsedcccccssesacectoscessiecensasidet cteuscceuessaduedesuncsesiestccuuscesvessisacecssscasdacsecesdeatecaewsieuccase 6 Inaustry Canada Notice 00 Users iarainn EE RO 7 FOR Body Worn Opel 200 It sasyisipri ai niaaa ENAA annette 7 Professional Installation Recommended nunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 7 Notice to Customers in AUStIAal1a ecccccccccssssesssecccccccsesssseecccececscesssseecececensssseeeeecneenssseseeeeeenanenasessesensannasssess 8 Restricted use with Certai
31. When mute lock is enabled the touch areas of the microphone are disabled The mute state of the microphone can only be changed by other microphones in the group or through the web user interfaces To set mute lock for a microphone click the unlocked icon that appears next to its mute icon on the Web UI s Monitor page The icon will change to a locked lock Clicking the icon again will return the microphone to an unlocked state Pee revolabs Warranty Revolabs Inc warrants this product to be free of manufacturing defects Repair or replacement of any defective part or unit at the discretion of the Seller will be free of charge for the period defined in the Revolabs Professional Products Limited Warranty Any attempt by the user to alter the equipment or equipment damaged by negligence accident or Acts of God voids this warranty The Seller shall not be liable for any consequential damage resulting from the malfunction of this product Should the user experience unsatisfactory performance from this equipment contact the Seller to obtain instructions for return or replacement as deemed necessary This warranty is not transferable by the original end user Complete details and terms of the Limited Warranty can be found at www Revolabs com Revolabs Inc 144 North Road SUITE 3250 Sudbury MA 01776 www revolabs com 800 326 1088 Pee revolabs GPL Licensed Software The following table lists the open s
32. XECMIC Revolabs Executive Tabletop Microphone FCC ID TSVO1IEXECMICWR Revolabs Executive Wearable Microphone FCC Notice to Users This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Users are not permitted to make changes or modify the equipment in any way Changes or modifications not expressly approved by Revolabs Inc could void your authority to operate this equipment under Federal Communications Commission s rules RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measure
33. age of the local web UI and press the pair button on the channel you want to pair the microphone to The LED on the front panel for that channel will turn solid red Once the LEDs on the front panel and on the microphone start flashing either red muted or green unmuted pairing is complete 4 If pairing fails the microphone LEDs will start blinking red green if it was not paired before If the microphone was paired to a different channel on the same Base DSP Station or to a different Base DSP Station before it will try to link back to that channel Previous pairing information is not deleted on the microphone during a failed pairing attempt j revolabs 92 LED patterns The following table shows activities associated with the various states shown by microphone or adapter mute LEDs Base DSP Station Se caida acai Channel LEDs Microphone in Solid yellow Battery Type Test Charger Base Solid red Charging in Progress Solid green Solid green Off Charging Complete Complete 2 RED flashes every 2 RED a Microphone is es its second a e second firmware over the air Off Non Non Rechargeable Batteries _ Batteries Microphone not in ae a off or Charger Base battery discharged Two red flashes Two red flashes Microphone paired and every 1 5 seconds every 1 5 seconds muted One green flash One green flash Microphone paired and live every 1 5 seconds every 1 5 seconds unmuted One red flash every
34. allation each requires its own connection to the control system in order to communicate To use the control system API the External Control Configuration setting the type of external processor and the connection method has to be defined to match the external control system s settings Executive Elite supports server mode or client mode for the control interface Selecting the right mode is required for correct interoperability with the connected control system When using a control system the Executive Elite can be configured for external mute on the External Control Configuration page of the local web UI When external mute is On the Executive Elite base DSP will always pass audio even when the microphones show that they are muted In this case it is the responsibility of the installer to ensure that mute is performed in an external component of the installation NOTE Both a control system and DSP cannot be connected to an Executive Elite Base Station at the same time When using a control system and DSP at the same time connect the Executive Elite Base DSP to the control system The external DSP must be controlled by the control system as well Serial Command amp Return Strings The Serial Strings of an Executive Elite Base Station begin with the Argument and terminates with a Carriage Return The Command String structure is as follows lt Argument gt lt Command gt ch lt Channel gt lt Value gt lt CR gt The argu
35. ally turn on Based on settings in the Base DSP the microphone will start either un muted or muted indicated by green or red blinking lights respectively 2 Omni Tabletop microphones can be centered on the table within 2 to 6 feet 0 6 to 2m away from people speaking and do not need to be pointing any particular direction because they pick up sound from all directions It is always better to place a microphone as close to the people speaking as possible while avoiding placing the microphone where it might be blocked by equipment or paperwork Do not place microphones too close to an audio or video conference speaker to avoid echoes Make sure that the microphone s rubber feet are sitting atop a flat surface 3 With the microphone in position on the table see picture above for an example mute or un mute the microphone by touching any of the four mute areas confirm by flashing green or flashing red LEDs respectively In push to talk mode touch a mute area and keep the finger there to unmute the microphone Removing the finger from a touch area will mute the microphone 4 To turn the microphone off return it to the Charger Tray or touch and hold any of the Mute areas for about 10 seconds until the LEDs turn solid red then remove the finger from the touch area The microphone can also be turned off from the local web UI or the room control interface In push to talk mode the microphone cannot be shut down using the mute areas If
36. are still paired to the system If microphones are paired the microphone pairing dialog will not open revo abs 58 Factory Default Settings Web UI Page Preamp Gain XLR style microphones Input Signal Trim High Pass filter all microphones 110Hz Default Setting Low Pass filter all microphones EQ 4 bands all microphones EQ Enabled all microphones Output Level mic line level all microphones Manage Groups Group Default all other groups deleted Group mute type tabletop push to talk individual Eo revolabs Web UI Page Network Mgmt Network Mgmt Network Mgmt Network Mgmt Network Mgmt Network Mgmt RF Power RF Power External Control Config External Control Config External Control Config External Control Config External Control Config External Control Config External Control Config External Control Config External Control Config Admin Online Access Online Access Front Panel Mic Audio Mic Audio j revolabs Default Gateway NTP Servers 4 Default Setting lt lt empty gt gt lt lt empty gt gt lt lt empty gt gt 192 168 10 4 290 209 22 99 0 nistl ny ustiming org nistl atl ustiming org nistl sj ustiming org Automatic on off Max power level External Control Processor External Mute on off Audio channels 1 8 9 16 17 24 25 32 Connection Mode Serial Telnet Line Speed 9600 19200 38400 57600
37. basic information about each system Additional functionality will be added as it becomes available NOTE The revoCloud website is cloudsupport revolabs com Revolabs revoCloud Create New Account Revolabs revoCloud allows remote monitoring and managing of Revolabs Executive Elite installations If your organization doesn t have an account yet please use the Create New Account page Or provide your previously created account information to access your Password account Email Address Forgot Password Login All data exchange between Executive Elite systems and the cloud server is secure using https protocol on port 443 Communication between the executive Elite and the Cloud server is restricted to system usage information microphone and battery usage information user access logging system change logging system logging RF information and system settings No audio data is ever transported to or saved on the Revolabs cloud server Be revo aos 63 Creating a revoCloud Account To create an account for use on the revoCloud Server first navigate to the Cloud Support web page at cloudsupport recolabs com The home page will provide a box for login information Click on the Create New Account button in the upper right hand corner Login Create New Account Email Address Password Forgot Password te Login To create an account an Organization or account name email address and pass
38. cess to the cloud server will be declined for the system and it cannot be managed through the cloud server RF Spectrum Analyzer The Executive Elite s Remote Antenna receiver has a built in RF Scanner which can be accessed through the RF Spectrum Analyzer page providing a color coded graph of the local RF environment activity RF Spectrum Analyzer Main Conf Room System 4 amp me Scan Active Running Time Peak Spectrum Activity Stop Scan Mi Open Ml Noisy Mi inUse 5 Frequency Bands 5 51 Mon Feb 24 2014 13 32 History Clear Avg Peak Estimated Available Mic Channels Mic Audio 90 Average Peak 30 a None 38 44 27 32 Back S 71 32 c H E Legacy HD 10 9 8 7 6 5 4 3 2 1 0 Minutes Q OQ RF Spe ctrum o After clicking the Start button in the upper left corner of the page the graph will fill in from the right to left The scan can be stopped at any time by returning to the page and pressing the Stop button but the information will B revolaos 54 be cleared from memory once the scan has been stopped and the page is redirected away from To save the scan result take a screenshot of the page before navigating away and store it using your preferred image editing application If you navigate away from the page while a scan is running the scan will continue in the background as other parts of the Web UI are used or even if the web interface is clo
39. chronization between the Executive Elite systems And finally OTA shows that synchronization is achieved over the air between the remote antennas in an installation The Clock Mode drop down menu allows specifying the clock source Internal sets this Executive Elite system as the clock source External indicates that a different connected system is the clock source and Automatic allows the Executive Elite Systems to check if it is receiving an external clock or if it should be providing one 3 Available in Version 1 2 revolabs 52 Network Management On this page Network Information for the Executive Elite is organized for easy access and management Network Management Maine Conf Room System 3 2 DHCP on off Server Addresses nist1 ny_ustiming_org nist1 atl_ustiming org nist1 sj ustiming_org Static IP Address Subnet Mask Default Gateway DNS1 DNS2 Static IP Address 192 168 10 4 Subnet Mask 255 255 255 0 The DHCP section allows enabling or disabling DHCP on the Executive Elite base DSP If DHCP is enabled the Executive Elite base DSP will request an IP address from your DHCP server If DHCP is disabled the IP section allows setting a static IP Address and other network information While DHCP is enabled these fields cannot be accessed and changed enabling DHCP will delete any data previously entered into the static address fields It is important that this information be filled out
40. d 12 inch Wireless Gooseneck Tabletop Microphones The Elite Wireless 6 inch and 12 inch Wireless Gooseneck Tabletop Microphones shown below are designed to provide optimum coverage when a personal microphone is being assigned for each participant in the meeting or panel 1 Mute touch area amp LED touch to mute un mute or pair the microphone LED provides visual status for mute un mute and pairing 2 Charging connector connects to the charging pins of the Elite charging tray or crossover adapter 3 Battery door latch open the battery door using this latch 4 Rechargeable batteries replace batteries only with NiMH 2000mA rechargeable batteries Non rechargeable batteries or rechargeable batteries of a different type or lower charge might impact performance of the microphone and might cause harm to the microphone users or the environment Using non approved battery types will void the warranty on the microphones When replacing the batteries ensure that the batteries are placed in the correct way as indicated by the print in the battery cavity of the microphone 5 Battery charge status LED warns about low battery 6 Additional LED provides visual status for mute un mute and pairing 7 Flexible microphone stem use to position microphone facing the desired direction Ee revolavs 85 To use either of the Elite Gooseneck Tabletop Microphones 1 Remove the microphone from the
41. d to be in this box If it is blinking an antenna is not communicating with the Base DSP unit If it is solid communication is passing between the Antenna and Base A UU Wired Sync Ifa wired sync buss is being used to sync clocks between Executive systems the synced Elites will show this icon Remember that sync mode must be set before the base will look for an external clock p USB When the front panel USB is in use this icon will show communication is being received through that port T AVB a L AVB When AVB is plugged into the Base the AVB icon will appear Until the Base is set up as a talker or listener the arrows above or below AVB will not appear To check if the Base is set up for either remember T is for talker and L is for listener Separated from the external systems box by a vertical line is the channel information section of the Front Panel UI At the top each channel is labeled and two rows underneath provide different information depending on which home screen is currently selected On all screens the top row will show microphone status beyond linked with the following icons a Microphone Lost Link or Unknown Status Microphone I Stand by Mode Firmware Update in Process Microphone channels that have no microphone paired a charging microphone or when the microphone is switched off will show no information Pee revolabs 29 Additional information fro
42. dify any of the batteries delivered with the Elite components Replace batteries only with Revolabs approved batteries e Extreme heat above 140 F 60 C short circuits or any attempt to open or modify the batteries might cause them to ignite explode and or release toxic material revolabs 11 Glossary AES 256 Advanced Encryption Standard 256 bit key length version Code Cypher used in the Executive Elite to encrypt the wireless signal and the audio communication between the Base DSP unit and the Remote Antenna Cardioid Microphone A cardioid microphone or directional microphone is directional picking up audio from the area in front of it and less or none from behind The pickup pattern is in the shape ofa Cardioid Channel Executive Elite can handle 4 or 8 wireless microphones per base For ease of use each microphone is assigned a channel number as part of the pairing Charger Base Storing and charging station for the Elite microphones Magnets in the stand hold microphones on while contacts supply charge if the charger base is plugged in A microphone in a powered Charger Base is switched off and charging if correct batteries are placed in the microphone DECT Digital Enhanced Cordless Communication Wireless Technology for audio and data applications using time division multiple access TDMA technology Directional Microphone A microphone that receives audio primarily from one direction
43. e of the LCD The user cannot leave the gain control screen while in channel selection mode To leave the screen press Enter again to get into the normal mode Up and Down will now switch between home screens again and using the Right arrow key will enter the main menu E revo aos 27 2 B LTT When changing the gain or entering any menu in the front control panel that allows the user to changing values a password prompt will appear before the user is allowed to proceed To enter the password use the right and left arrow keys to select a digit and the up button to change the number of that digit O 9 Hitting Enter will submit the password and down brings the cursor to the cancel button On the front panel the password will be valid for 20 minutes unless the user explicitly logs out in the Admin Settings submenu as described further below The factory preset password is 7386 and can be changed either through the Admin Settings menu on the front panel interface or the System Configuration menu on the local Web UI Pee revolabs All three home screens are split into 3 sections and each section shows a different type of information On the far right hand side of the screen the Home screen name is displayed at the top of the external systems information box Underneath it there can be up to 4 icons showing if certain external systems are connected Antenna The only icon guarantee
44. ed and online access needs to be enabled B revo aos 61 Software Upgrade The Software Upgrade page offers two different methods to upgrade the firmware of an Executive Elite system System Software Upgrade Software Version 1 0 23 Check for Latest Version r ae o me Select software file and start upgrade Browse for Software File 1 An Executive Elite system registered to the Cloud Server may use the Check for Latest Version button to search revoCloud for the most recent version of the product firmware available on the server If that release doesn t match the current firmware on the Executive Elite system the Executive Elite will offer to upgrade through the Cloud This method will not work if the Executive Elite has not been registered or Cloud Server access is disabled 2 Browse for Software File requires a software bundle to exist on a computer or server the Elite s Web UI has access to Browse to the software file select it and the Executive Elite system will load this version into the system For more information on firmware upgrades see page 76 revolabs 62 revoCloud The revoCloud Server is a Web Client allowing for remote access and control of multiple Executive Elites from any computer with an internet connection From the revoCloud website cloudsupport revolabs com Administrators can check which Executive Elite systems are online and up to date as well as accessing
45. ed ground G a To connect audio In Out on the Base Station 1 Use the screws on top of the connector to first open the terminals 2 Insert an appropriate 3 conductor cable 2 conductors and shield into the terminals 3 Tighten the screw to secure the cable 4 Push the connector onto the pins centered under the desired input or output port on the back of the Base DSP unit until firmly secured The microphone output connectors need to be attached to the line level OdBu input connectors of the post processing audio equipment mixer DSP If the analog audio in is used for the back channel audio the Base DSP Unit input connectors also OdBu may then be attached to the output channels of the post processing equipment revolabs 22 AVB Audio Beside the analog audio Executive Elite also supports digital audio input and output The AVB connection on the back of the Base DSP unit can be connected to an AVB enabled network and delivers streams of output audio data for each microphone as well as can consume streams of input audio data for each microphone For information on how to set up an AVB network and define AVB talkers and listeners see your AVB network management software Synchronizing Executive Elite units If more than one Revolabs Executive Elite Base DSP unit is used in an area the units should be synchronized to ensure best usage of the radio frequency space and best system performance The Executive
46. ed microphones are listed Selecting any of these microphones will present the information on that specific revolabs 32 microphone including microphone type firmware version and the ID of the microphone In the Network Information section the three different networks available to the user are each given a submenu Network Information LAN provides information about the standard LAN connection including whether DHCP is enabled or disabled the IP address of the base DSP unit in the LAN network the MAC address of the interface as well as other network information The Network Information USB option provides network information for the USB connector on the front of the Elite base DSP Finally Network Information AVB provides information on the AVB connection in the back of the Elite base DSP unit This includes the link status the MAC address of the interface the PTP mode and the MAC address of the AVB master System Settings Region system Settings 1 USA Canada 1 Remote Management On Off Region RF Power System Clock RF Power Admin settings 1 Auto Scaling on off 2 O 20 ft 0 6 m 18 Venezuela 6 150 300 ft 46 90 m System Synchronization 1 Local 2 Sync Bus 3 AVB 4 System Clock Mode Admin settings 1 Set Password 2 Log Out The System Settings submenu allows the user to control some of the Executive Elite s system settings The Remote Management checkbox at the top of the m
47. ed off from the local web UI or the room control interface In push to talk mode the microphone cannot be shut down using the mute area If the microphones are placed too far away from the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or more the connection will be dropped LEDs flash red yellow green yellow and the microphone will mute After 15 seconds the microphone will beep and will continue beeping every 30 seconds to indicating that it is out of range Move the microphone closer to the Remote Antenna and the connection will automatically be re established to its original state and the beeping will cease Otherwise the microphone will continue beeping until it turns off after about 15 minutes revolabs 86 Elite Wireless XLR Adapter The Elite Wireless XLR Adapter allows dynamic hand held microphones to be used with an Executive Elite system 1 Earpiece jack accepts a 2 5mm earpiece plug 2 Battery door push towards the back of the microphone to open the battery compartment 3 Li Ion rechargeable battery can be taken out and replaced after opening the battery door Replace batteries only with Revolabs approved rechargeable batteries 4 Battery charge status LED warns for low battery When there is approximately 2 hours of talk time remaining this LED will turn yellow When the LED turns red there is approximately 1 hour of charge remaining 5 Mute LE
48. eeeeseeeeceeeeceeseeseeeneeseeneeseeseeseeseeeneeseeneeneeseesoeseesoesensnneneeseesoesoesensensensensanes 67 ACCOUNL MANAG eme D Es E 67 Serial Control Processor Room Control Interface ssssssssnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 68 Fi WAS UU ACCS eS 76 Eo revolabs PUPN ONO TNS acess eee veneer ce eee evar een eee nee ence e nseats vos sas enon sheessuevneeuacesbeesventbcecessenaeeas 77 The Elite Wearable Wireless Microphones sussussnsunnnnnunnunnunnunnnnnnnnnnnnnnnunnnnnnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 78 The Elite Omni Directional Wireless Tabletop Boundary Microphones cssssssssseeseeesseees 81 The Elite Directional Wireless Tabletop Boundary Microphones s sssssssssunnunnunnnnnnnnnnnnnnnnnnnnnnnnnne 83 The Elite Wireless 6 inch and 12 inch Wireless Gooseneck Tabletop Microphone 85 Ente Wireless XLRAOIDIOT en ESSES ra AA eE aS ASAA aa aai 87 The Elite Wireless TA4 mini XLR Adapter for lapel and ear set microphones 0000008 89 RS ainssi E ces cece cs ccc aan ec cet ecealan ov sentences nsec st cu nen duce ueaseen nev aee cated eetions 91 Pairing Wireless Microphones to Remote Antenna and Base DSP Station sssessnsnsens 91 BED AUG FNS a A A A A E A E A A E T O A E EE T 93 Mute Groups sssiissssiskiranannniaii ninnisin eaaa an aaia a iaaii Aaaa Raapa aAa 94 WY AD AIG A E E EEA E E EE E E E 97 CPLEICCNS OA SOW AUC e E E S 98 POUND SUMO CN ia E vant ea peace eae ste agea vetuaee
49. efined for this system on the left and the currently active group on the right side Pressing the sign 1 in the top left of the right column will create a new group A group name needs to be entered to create the group Each Executive Elite Base DSP unit and therefore every Base DSP cluster can have up to 10 mute groups within that cluster Delet mute groups that are no longer required in your installation To manage and change a group the group needs to be the active group on the right side of your screen The group name of the active group is shown in the Group field 2 To select a different group as the active group either select it from the drop down in the Group field in the right column or click on the Edit button 3 of that group in the left column The group will now be opened on the right side of the screen To delete the active group click on the trash can symbol 4 The only group which cannot be deleted or renamed is the Default group To change the name of the active group click on the pen symbol 5 and enter the new name a revoaos 47 Once a group is active for management microphones can be added to it Select any microphone currently in another group listed in the left column and drag it over to the right column to add it to the active group To remove a microphone you can mouse over the microphone you want to remove and click the x symbol on the top right automatically adding tha
50. enu enables and disables the room control CLI interface on the base DSP unit The Region menu allows selecting the region in which the Executive Elite system is used NOTE You need to select the region or country you are using the system in As part of this selection the frequency band in which the revolabs 33 Executive Elite system operates is selected Selecting a country or region different from the one you are in might revoke the right to use the system If you are unclear which region or country you should select please contact Revolabs support The RF Power settings allow adjusting the RF signal strength of the receiver limiting RF traffic and interference with other areas It is recommended to select an RF setting that provides good RF coverage with minimal local area interference An RF Power setting that provides a signal strong enough for a microphone to be 150 300 feet away from the remote antenna receiver might also be seen by other Revolabs devices in the vicinity We recommend testing with different RF settings and using the RF Spectrum Analyzer in the local web UI to gauge the effect of the different settings Auto Scaling should be disabled except in high RF environments as it allows the system to automatically reduce RF power when it is not required The System Clock menu allows setting the synchronization mode of the Executive Elite system After selecting a mode the system will open the System Clock Mode
51. er in this document The front panel contains four areas 1 On off switch 2 4 8 LEDs depending on the version of the Executive Elite base DSP unit 3 Graphics LCD display 4 5 button navigation keypad The on off switch powers the Executive Elite base and the connected remote antenna receiver on and off During operation this switch should be in the 1 or on position The LEDs on the front panel show the current microphone states An LED that is off indicates that there is either no microphone paired to this channel or the paired microphone is in the charger out of reach or switched off A green blinking LED indicates an active microphone that is unmuted A red blinking LED showing a double blink indicates an active microphone that is muted A rapidly red blinking LED with a single blink indicates the microphone is upgrading A constant red LED indicates a channel on which microphone pairing is taking place at the moment The LCD screen together with the navigation keypad allows easy monitoring of the Executive Elite system as well as managing some system settings without additional equipment Its home screens provide information on audio levels radio signal strength and access to gain settings for the analog audio output The menu structure displays system information and allows changes to some system and audio settings The front panel can also be used to pair and un pair microphones It does not replace t
52. erence speaker to avoid echoes Make sure the microphone is sitting on its rubber feet and not on its side 3 With the microphone in position on the table see picture above for an example mute or un mute the microphone by touching the mute area confirm by flashing green or flashing red LEDs respectively In push to talk mode touch the mute area and keep finger there to unmute the microphone Removing finger from a touch area will mute the microphone 4 To turn the microphone off return it to the Charger Base or touch and hold the Mute touch area for about 10 seconds until the LEDs turn solid red then remove the finger The microphone can also be turned off from the local web UI or the room control interface In push to talk mode the microphone cannot be shut down using the mute area If the microphones are placed too far away from the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or more the connection will be dropped LEDs flash red yellow green yellow and the microphone will mute After 15 seconds the microphone will beep and will continue beeping every 30 seconds to indicate that it is out of range Move the microphone closer to the Remote Antenna and the connection will automatically be re established to its original state and the beeping will cease Otherwise the microphone will continue beeping until it turns off after about 15 minutes revo aos 84 The Elite Wireless 6 inch an
53. esn t have an account yet please use the Create New Account page Or Login provide your previously created account information to access your account Email Address Password Forgot Password Login D ine revoCloud Home After registering a revoCloud account log in using the email address and password of the verified account If no system has been registered to this account yet the home page will list that there are no registered systems at this time Systems No devices found for revo revolabs com To register a device for remote access use the Elite system s local web interface The Elite system s setup wizard provides an option to register the device If the initial setup has already been completed choose the Online Access option from the System Management menu From that page you can provide your cloud account details and register the device Registration of systems needs to be initiated from the Executive Elite local Web UI Navigate to the Online Access page of a system that was previously configured or use the Initial Setup wizard of a new system to register the Executive Elite system to this cloud account revo abs 65 Once an Executive Elite system has been registered to the cloud account the home page will list the registered systems Systems 1 Upgrade Firmware to version 1 0 0 344 System Name Online IP Address Cluster FW Version Maine Conf Room System 4 em 10 134
54. group status_change_antenna_link Eo revolabs notify mute_group_change lt group name gt lt action gt notify mute_group_member_change lt group name gt bid lt box id gt active lt 0 1 gt type lt type gt index lt mic index gt notify mute_group_mute_type_change lt group name gt lt mute type gt notify set_mute_status ch lt channel number gt lt mute gt lt mute type gt lt mute lock gt notify startup_unmute_group lt group name gt lt state gt notify status_change_antenna_link lt status gt Notify client that changes that affect a given group have occurred Actions include add add del delete ren rename Notify client that a mic has changed its group Notify client that the given mute group s mute type has changed O Individual mute 1 Tabletop mute 2 Push to talk Notify client the given microphone s mute status changed lt mute gt values O unmuted 1 muted lt mute type gt values O Individual Mute 1 Tabletop mute 2 Push to talk mute lt mute lock gt values O unlocked 1 locked Notify client that the given mute group s unmute at startup setting changed 1 unmute at startup O mute at startup Notify client antenna link status changed O unlinked 1 linked 74 Notifications Notification Format status_change_battery status_change_mic status_group_mute Batt Mute Type notify status_change_batte
55. he local web UI interface or the cloud based management interface to manage all options and functionality of an Executive Elite system The front panel interface will also not allow access to password protected areas of the interface unless the system has first been set up using the local web UI j revolabs 26 Home Screens When starting an Executive Elite system the first page that comes up on the Front Panel LCD is the Volume Unit VU screen This screen is one of the 3 home screens on the Front Panel UI Using the up and down keys to the right of the LCD while on the VU page will show the other two home screens 29998 Ep The VU screen shows the audio volume for each unmuted linked microphone as well as battery charge information 3 4 Up from the VU screen the RF View home screen shows the radio signal strength as measured on the receiver for each microphone RAT OGOOQO Down from the VU screen the Gain control screen shows the VU meters as well as the input gain setting for each microphone channel which the user can change from this screen To adjust the gain a user presses the Enter while on the gain screen and a black highlighted selection will appear The channel is selected using the left and right keys and once in the correct channel the up and down keys change the gain in 1 dB steps The gain setting for the highlighted channel is listed on the right hand sid
56. he webpage allows checking the Cloud Server for an upgrade An unregistered Executive Elite system can be upgraded from the Web UI using an upgrade software bundle accessible from the computer connected to the Executive Elite system as described on page 62 Upgrade bundles are available on Revolabs website in the support section Firmware upgrades upgrade all linked components on an Executive Elite system e The Software Download pages show the progress of the Base then Antenna upgrades in that order e After the upgrade is successful linked microphones will begin upgrading over RF If microphones are not linked they will begin upgrading the next time they are linked e Microphones in a charger will still upgrade as long as they are paired to the Elite unit that is upgraded e An upgrade of the Base unit and the antenna takes about ten minutes e Depending on the System Audio Setting Microphones can take up to 6 minutes to upgrade Audio modes in which back channel audio is disabled will take longer to update the microphones revolabs 76 Microphones Revolabs Executive Elite offers a wide variety of wireless microphones and adapters to use with the system Revolabs Elite Wearable Wireless Microphone Revolabs Elite Omni directional Tabletop Wireless Boundary Microphone Revolabs Elite Uni directional Tabletop Wireless Boundary Microphone Revolabs Elite 6 inch Tabletop Gooseneck Microphone Revolabs Elite 12 inch Table
57. i FILTERS 15 1 15 15 15 10 15 10 15 15 2 2 2 0 20 2 EQ i dg 0 dB 0 0 dB 0 dB 0 dB 0 0 dB 0 0 dB 0 Mic Line Mic Line Mic Line Mic Line Mic Line Mic Line Mic Line ANALOG Gain Level Gain Level Gain Level Gain Level Gain Level Gain Level Gain Level D E a G a Q C Qu C e OUTEUR gt ea 12 z 4 gt 2 z 4 ai amp 2 0 0 0 0 0 0 0 0 24 4 4 i 24 4 4 i 24 1 35 10 10 z 1 1 1 10 35 0 60 A TTT TY fa pa n rN pa n rN n GRRGRGREE f pa n rN ta ey RA n DIGITAL OUTPUT The microphone audio page allows setting audio parameters for each microphone individually The page is structured into two areas The top area is set up for adjusting the input signal and processing the signal by applying filters and EQ settings to the audio The bottom of the table is focused on output signal and an output gain stage as well as the microphone line level setting for the analog audio output Input Signal The Input Signal area allows trimming the input signal for each microphone separately allowing for input levels of different microphones to be optimized individually For XLR and TA4 adapters an additional pre gain stage is offered The Revolabs microphones omni directional directional gooseneck and wearable are set to provide signals on the same level with a focus on providing the best signal to noise ratio with the lowest risk of clipping of audio XLR and TA4
58. ill be dropped LEDs flash red yellow green yellow and the microphone will mute After 15 seconds the adapter will beep and will continue beeping every 30 seconds to indicating that it is out of range Move the adapter closer to the Remote Antenna and the connection will automatically be re established to its original state and the beeping will cease Otherwise the adapter will continue beeping until it turns off after about 15 minutes j revolabs 90 Batteries Replace batteries in the microphones only with Revolabs approved batteries The tabletop microphones require standard Nickel Metal Hydrate NiMH rechargeable batteries with a 1 2 V voltage and a charge capacity of 2000mAh Example batteries following these specifications are Sony NHAAB4KN or Panasonic HHR 210AAB Revolabs warranty is voided if a battery is used that e uses a different battery technology than rechargeable NiMH batteries e uses a battery with a different voltage than the required 1 2V e uses a battery with a different charge capacity than the required 2000 mAh The wearable microphone as well as the XLR and TA4 adapters use a custom Li Ion rechargeable battery Use only Revolabs provided batteries for these microphones Using any other battery will void Revolabs warranty Caution Risk of explosion if batteries are mishandled or replaced by an incorrect type Do not disassemble batteries or attempt to charge outside the system Do not dispose of bat
59. ion bus the Mute Groups in each of these Clusters and unclustered Executive Elite Base DSPs are independent of each other and do not affect the maximum number of mute groups in each Cluster or Base DSP NOTE To find other units in the same cluster Executive Elite units communicate over the IP network using port 5001 While this port is typically blocked in routers and firewalls going in and out ofa corporate network you should ensure that this port is open inside your network but closed going out of your network Executive Elite bases that are assigned to the same cluster and that are in the same subnet will communicate mute information between each other Groups by the same name on different Executive Elite bases in the cluster are automatically assumed to be the same group so when mute information is being exchanged between these bases mute changes to the same named groups will affect microphones on both Elites All Executive Elite base DSP units have one group called Default which contains all microphones of a newly configured system j revolabs 46 Manage Groups Maine Conf Room System 3 2 Elite Box 1 1 Group Presenter 2 v gt 4 Mute Type Individual Mute v Unmute Mic F Startup Chairman non AUUE LTE TableTop Mute Push to Talk 7 3 l Edit K Ke Ken c Ka Ke Ken To add mic to group drag mic to the right panel The Manage group screen shows a list of the groups d
60. iring is started from several Base DSP Units and microphones in parallel microphones might pair to any of the Base DSP Units currently in paring mode Both the front panel interface and the web interface support a pairing wizard managing pairing of several microphones in succession This supports setup of new systems with multiple microphones to be paired To pair an individual microphone to the Base DSP Station and the Remote Antenna 1 Turn the microphone off no LED activity If the microphone is ON touch and hold the Mute area or press the mute button for about 10 seconds until the LED turns solid red Release the touch area or mute button to turn the unit off Note that the microphone beeps once after about 5 seconds while holding the mute button This does not indicate that the microphone is switched off 2 Place the microphone into pairing mode by touching the Mute area or holding the mute button for several seconds until the LED turns solid red and then release the touch area or button The LED first turns green do not release the touch area at that time Once the LED is constant red the microphone is in pairing mode 3 Within one minute put the desired channel of the Base DSP Station into pairing mode using either of the management interfaces of the Elite Base DSP Station See page Error Bookmark not defined on how to puta microphone channel into pairing mode using the front panel or go to the monitor or microphone audio p
61. is a standalone system Next gt The New Systems Configuration page asks for system information The system name will help identifying the system in multi system installations It is mandatory to provide aname Country Region is required to define wireless settings in the system You need to select the country or region in which the system is being used NOTE Selecting a different region than the region you are using the system in may void your right to use the system If you are unsure about which region to select please contact Revolabs support at support revolabs com Cluster Name allows for common microphone group definitions across several Elite Systems Elite Systems that are in the same Cluster will find each other in the network and coordinate mute commands This allows definition of microphone groups across several Base DSP units enabling mute behavior across larger groups of microphones In standalone systems that are not supposed to coordinate behavior with other systems do not provide a Cluster Name If you are not sure whether this system will be part of a Cluster or you currently do not know the cluster name do not provide a name at this time Wee revo avs 39 You can enter a Cluster Name later through the System Configurations page of the web user interface Click Next once you have provided the information on this page Revolabs Execute Elite New System Configuration 2 System Registration To
62. isher Revolabs Inc a Location http 10 134 122 748 This application will run with unrestricted access which may put your computer and personal information at risk Run this application only if you trust the location and isher above OIC Bo not show this again for apps from the publisher and location above ij More Information The Monitor page provides current status information for the microphones in your current system The page lists the microphone channels either in B revoans 41 numerical order or sorted by groups and information on each channel If no microphone is paired on a channel a pairing button is provided to pair a microphone The top line provides the group name Factory preset all microphone channels are assigned to a group called Default Maine Conf Room System 3 View hy Group Mic Manage Groups F lable group Panel table Lectern Presenter HEL TYPT Cerri WERA Directa Dao crk cea Fini WLA Hiini NERA STATS Da Da f ot Pored Pair BATTERY P i icv M qpr IEE ay i 26 m 5 a ii OUTPUT H Liwii E z Aa T N RTT T T i ETT il rat santa oa abil z Hiatt Groep Mute Group j Mute Group Mute Groop Ilao 22 nh T 5 DO a mA m i m ERITI 6 om g6 og y A al ies 2 23 a c 2 J 1 Mute Lock Button Enable or Disable mute from the microphone 2 Chairman Symbol This Microphone is set as Chairman for its group 3 Individual Mute Button Works like
63. it will be used at unmute it and go to the Microphone Management page of the Web UI The TA4 adapter s column will have a Pre Amp gain setting once the adapter is paired This slider will allow different types of microphones to be integrated with the Executive Elite sound system Select the highest setting on the pre amp where clipping is not observed to allow for the highest signal to noise ratio 4 Based on the mute behavior defined for the adapter in the local web UI mute or un mute the microphone by pressing the mute button on the adapter confirmed by flashing green or flashing red LEDs respectively In push to talk mode press the mute button and keep the finger there to unmute the microphone Removing the finger from the mute button will mute the microphone again 5 To turn the mini XLR adapter off return the unit to the Charger Base or press and hold the mute button for about 10 seconds until the LED turns solid red then release the button The adapter can also be turned off from the local web UI or the room control interface In push to talk mode the adapter cannot be shut down using the mute button NOTE Do not place the TA4 adapter into the Charging Base while the handheld microphone is still attached Place only the adapter in the Charging Base If the adapter is placed too far away from the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or more from the Remote Antenna the connection w
64. ith Revolabs Executive HD systems Channel The options for the lt Channel gt portion of the serial strings are 1 8 for an Executive Elite 8 and 1 4 for an Executive Elite 4 system since each Base station can only control its own 8 or 4 microphones respectively The lt channel gt corresponds to the channel number the microphone is paired to in the Executive Elite A lt Channel gt of A will control all microphones Examples The following string would set microphone channel 3 to be the chairman microphone for its mute group Command set chairmanmic ch 3 1 Return val chairmanmic ch 3 1 The following strings would turn off all microphones on the Elite Command set shutdownmic ch A Return val shutdownmic ch A The following strings would retrieve the battery status of microphone 5 98 Command get batterystatus ch 5 Return val batterystatus ch 5 98 j revolabs 69 String Tables The following table includes a number of the Elite s commands Both Executive HD legacy commands and new generation Executive Elite commands will work when programing for the Executive Elite Please consult the Room Control API document available at http www revolabs com su ort for the complete list Command Format get audioquality Property Action audioquality audioquality backchannel backchannel batterystatus chairmanmic chairmanmic chairmanmicgroup chairmanmicgroup chairman
65. iver contains several antennas to provide the best transmission and reception of the radio signal to and from the microphones Routing channels Be revo aos 19 The back plate of the Remote Antenna Receiver provides means to install the antenna in different environments See the below diagram on how to install in the different environments Independent on which way the wall plate is attached do not over tight the screws When installed on the wall or on an electrical one gang or two gang box the network cable can be routed through the Network cable opening Alternatively the network cable can be routed to leave the Remote Antenna Receiver either on the top or the bottom using the provided routing channels TOP O Four corner holes wall installation C Four central holes US single gang or dual gang C Two outside horizontal holes European single gang C Two inside horizontal holes Under ceiling installation Network cable opening WA a lo _ OPRAO Once the back plate is attached to the wall and the network wire is connected to the Remote Antenna Receiver and routed correctly the Remote Antenna enclosure is attached to the back plate by slipping it from the top onto the two hooks and then pressing the bottom back against the wall plate until the snap clicks in To separate the Remote Antenna Receiver housing from the wall plate insert a screwdriver from the bottom into the slit and press
66. ler through the process of pairing them to the available channels If revo abs 40 microphones are not ready to be paired at this time they can be paired from the Web interface later on Once pairing is finished or if later was selected on the pairing page the Local Web UI will redirect to the Monitor page This page will also be the first page to come up after logging in on all future visits to the Web UI Monitor Page The local Web UI requires Java applets to provide real time information on the system status and manage the system Therefore when entering the page the first time and depending on the web browser that is being used two warnings might be displayed The first one asks to run Java and depending on your preferences you might allow Java to run on this page this time or always NOTE If Java is not enable on your computer or you do not allow the Java applet to run the local web UI cannot provide all of the system information changes to settings might not be communicated to the Executive Elite base DSP and the user might be barred from some features of the web UI The web browser might also ask permission to run the Java application Again depending on the preference you may allow Java to run just this time or always If you check the box on the screen a trusted security certificate is added to the Java security settings Do you want to run this application r Name RevolabsDeviceManager S 2 Publ
67. ll therefore only provide synchronization data not mute data between Executive Elite and Executive HD systems However mute groups managed between Executive HD systems can still be managed using the bus The synchronization bus cable is connected to the grey Euroblock BUS connector on the Executive Elite Base DSP unit using a standard 3 5mm Euroblock connector The wire used should be 20AWG or better shielded cable The distance between the furthest External and the Internal must not exceed 300 90 meters The terminals of the BUS connector should be wired in parallel via either a daisy chain connection or terminal block split The three contacts of the Euroblock connectors are as follows from left to right S Sync a Not used in Executive Elite Master Mute in Executive HD 8 G G Ground ZER If the synchronization bus is used to synchronize Executive Elite systems with Executive HD systems one of the Executive HD systems needs to be set as the Internal making that system the clock master All Executive Elite Base DSP units will have to be set to use the external clock AVB Synchronization If all Executive Elite Base DSP units are connected to the same AVB network the AVB network can be used to synchronize the systems with each other This simplifies installation of Executive Elite systems as no additional revoaos 24 synchronization bus is required However it does not allow synchronization in a mixed en
68. m number of microphones that can be used in that environment If back channel audio is provided the source for that audio needs to be defined It can come either from the analog audio in ports on the base or through AVB audio in The web page does provide information on the expected number of microphones that can be active in the selected audio mode in one room This number does not take into account other Revolabs systems and microphones already in use or other DECT equipment in vicinity See page 55 on how to use the RF spectrum for actual RF traffic in the DECT space and its impact on the use of Executive Elite microphones revolaos 49 NOTE Systems in vicinity of each other and either connected via a synchronization bus synchronizing via AVB or synchronizing over the air should all use the same System Audio settings Max Microphone availability will be significantly reduced if different settings are being used Legacy mode should be used if the Executive Elite Base is connected via the synchronization bus to an Executive HD unit Legacy will not allow disabling the back channel audio System Management The System Management section of the local web user interface contains information on the Executive Elite system and its components as well as system settings The various submenus are described below System Information The System Information page provides information on the Executive Elite s components Gene
69. m this row can be found in the following forms Q Mute Symbol Will show on the VU screen for a linked muted microphone VU or Gain Meters VU screen shows a VU meter for a linked unmuted microphone while the Gain screen meters look the same but do not change unless set and appear for all linked microphones RF Meters The RF screen will display the strength of the transmission from any linked microphone as it is received by the base Microphones experiencing interference or far away will have a lower RF The second row displays battery information when seen on the VU and RF screens using the following icons _ ie For a linked microphone the battery level icon will show the charge level by the amount of black in the battery While in the charger the battery symbol also shows a charging symbol overlaid over the battery charge icon Le A microphone using a permanent cross over adapter will be shown with a power connector battery symbol A permanent cross over adapter is one where the microphone does not use batteries L P A battery symbol with a indicates a non rechargeable battery or wrong battery type Such a battery will not charge when placed in the charger tray The type of a battery is only determined when the microphone is placed in a charger after inserting a new battery Up until this time the battery symbol will show a battery with a question mark in it indicating that the battery type is unknown
70. mber of microphones that can be used at the same time in one area The local Web UI provides additional information on the recommended maximum number of microphones per area based on each setting If the Executive Elite system is used together or in proximity with legacy Revolabs systems Executive HD the Legacy Mode selection should be used for best integration Compared to the HD audio implementation in Executive Elite Legacy Mode requires more RF space per microphone It should be turned off in environments where no Executive HD systems are present The back channel audio checkbox enables or disables return audio from the base to the Executive Elite microphones If back channel audio is not used this option may be switched off to open additional RF space If the Executive Elite system is used in Legacy HD mode the checkbox cannot be unselected as legacy systems require the audio back channel revolabs 35 NOTE The System audio page in the local web UI provides information on the recommended maximum number of microphones for each selected setting The RF analyzer page in the local web UI shows the exact use of the RF space and provides information on additional microphones that can be added based on average and peak activity in the RF environment The High Pass and Low Pass filter menus manage audio filters for each microphone High Pass filters should be used in rooms that have high level of background noise from air conditio
71. ment is either set or get A subset of the available commands is listed below For a full list of commands visit the Executive Elite Control Interface documentation If specific microphone channels are affected by the command the string ch is followed by the microphone number and then the value which is sent set command revolabs 68 All variable changes on any microphone or the Executive Elite Base Station will result in a Return String A Return String will begin with val and terminate with a Carriage Return Return Strings will be received for every value change that has taken place in the microphones or base station including changes that are a result of a Command String sent to the Executive Elite Base Station but also for changes initiated from the microphone or the web interface or front panel interface The Return String structure is as follows val lt Command gt ch lt Channel gt lt Value gt lt CR gt Executive Elite s Command interface is backwards compatible with Executive HD s command interface Control applications written to control HD systems will also work with Executive Elite systems The Executive Elite system s control interface has to be configured in the same way the Executive HD s command interface was configured The Command Interface of the Executive Elite has been expanded significantly with additional and new functionality These commands will not work w
72. microphone and might cause harm to the microphone users or the environment Using non approved battery types will void the warranty on the microphones When replacing the batteries ensure that the batteries are placed in the correct way as indicated by the print in the battery cavity of the microphone 5 Battery charge status LED under the screen warns for low battery The LED will turn yellow when there are 4 hours of talk time remaining and red for the last two hours of charge 6 Status LEDs provide visual status for mute un mute and pairing We revo aos 93 To use the Elite Directional Tabletop Microphone 1 Remove the microphone from the Charger Base The microphone will automatically turn on Based on settings in the Base DSP the microphone will start either un muted or muted indicated by green or red blinking LEDs respectively 2 Directional Tabletop microphones should be located on the table with the metal screen facing toward the users trying to keep the microphone 2 to 6 feet 0 6 to 2m from the target people The pick up pattern for this directional microphone is approximately 65 to either side of directly in front of the microphone Refer to the diagram below It is always better for the microphone to be as close to the person speaking as possible but avoid placing the microphone where it might be blocked by equipment or paperwork Avoid placing microphones too close to an audio or video conf
73. mute T revolabs set audioquality lt 1 2 gt get backchannel set backchannel lt 0 1 gt get batterystatus ch lt channel number gt get chairmanmic ch lt channel number gt set chairmanmic ch lt channel number gt lt 0 1 gt set chairmanmicgroup ch lt channel number gt lt group name gt get chairmanmicgroup lt group name gt get chairmanmute ch lt channel number gt Retrieve the audio quality setting 1 SD 2 HD Configure audio quality setting 1 SD 2 HD Retrieve the back channel setting O off 1 on Configure back channel setting O off 1 on Retrieve the given microphone s battery status Retrieve the given microphone s chairman state For response O non chairman 1 chairman Configure the given microphone s chairman state O non chairman 1 chairman Configure a microphone in a certain group to be chairman mic Get current chairman mic in the given group Retrieve the given channel s chairman mute state O all unmuted 1 members muted 2 all muted roduct line executive elite val audioquality lt 1 2 gt val audioquality lt 2 gt val backchannel lt O 1 gt val backchannel lt O 1 gt get batterystatus ch lt channel number gt lt percentage gt val chairmanmic ch lt channel number gt lt O 1 gt val chairmanmic ch lt channel number gt lt O 1 gt val chairmanmicgrou
74. n douaroleeuecnents 100 Accessing the Web UI through the Front Panel USB ssssssussssusunnunnununnununnunnnnunnunununnunnnnunnnnunnnnnnnnnnnnnn 100 Antenna SyYMDVOU BINRIN dcissietiirncniiiininisiintinniiinnsnintinnieiniini inet 100 Technical SU OTC iicssitscessscce sectet cece encase seoncccsseesuccatcctacedsconncosssoesccatuceuecenectsendescueesoasncesasceasucsecnctoectbes 100 SPCC ICAO INS scccsiccetaistccescencactenoncesettonasdeuncenaceoecncattexoeanaetioussdcendcessucusnestheuasaesscoausedenadeaacubuentesmnorancets 101 Microphone Polar gt Lae ge saraaa a 102 DON ees heen ecu eee icc ect et ceca woe sate ee esicsuiar ene tetones Ue vesse sates cuesauh senn cuceneceeslsGoeystasdouesesebuesuetbceaueeds 103 j revolabs Introduction Congratulations on your purchase of the Revolabs Executive Elite Wireless Microphone System This system utilizes state of the art technology providing high bandwidth audio and enabling clear reliable untethered audio capture for your applications Please read this documentation carefully and follow the instructions before installing and using your Executive Elite Wireless Microphone System revo abs Safety and General Information Please read the following information to ensure safe and efficient use of your Revolabs system FCC User Information FCC ID TSVOLEXEC Revolabs Executive 8 Channel Base Station FCC ID TSVOLEXEC4 Revolabs Executive 4 Channel Base Station FCC ID TSVO1E
75. n medical devices vecccccccccccccccccccssssssececcceeeeeeeceeeeeeeeeeeeeeneessesseeeeeeeeeeeeeeeeeeeennnons 8 EXport LAW ASSUMING CS cst snesnes sutuiacacnseaulicutestaeiustasucenatscuarseutoctssecevacanvidectasanssatitoutessberunveriduuievetansandiucesavauae 8 North America UPCS Usage Restriction ssussussununnunnunnnnnunnunnunnnnnnnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nananman 8 European Union Usage Restriction sssssussussunnunnnnnnunnunnnnnunnnunnnnnnnnunnunnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nannan 8 Notice to European CUSCOING IS ssssioisis saai aar raaa araea raan aiao Bars riis 9 WEEE Notification siete sastonsinccacsinacansetuuendsudscncsvseadenstrineacduunseyetedsusevssseninviatinicsesorsieseseuinsenieriviiatteluanitutensterecsuel 10 SY W Aa S erar E cannccescencand onscausoes ues desietecdeeesewsteseuse 11 CEO SS ATI ee E E 12 COMpPonentS siciiscnrsstntusiseraccansndteuatarccesarsuiudessvanessuuenisauaruanesunvsunacusceiuinaturdesuaiiunadeiivsadusieauaivateaiivensiuvecenics 14 Installation ssi csitrasctsdeciaeccsscadcercedessdnaeuessdarestescadurvienadanissdusavaasdanestssiateuetesssnsivsisiessieiatedeatienseissanedsbaderieziens 17 AS SP Da aia c se wee ecce lewn ce des S 17 Remote Antenna Receiver wissssccssssssscccccecsecccccecsseccceeesseeeccceesseeccenesesecenensseeeenessseeeanenssseeenenseseeenenasseeenencsseeess 19 Connect Remote Antenna Receiver to Base DSP Unit usssunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
76. ners projectors etc Low Pass filters should be used in applications and installations that do not support wide band audio to ensure that no unwanted side effects occur Microphone Management Microphone Management Pair All Wizard Pair All Wizard Wizard guiding user through Microphone 1 unpaired pairing of all microphones Microphone 2 paired Microphone 3 link lost Microphone 4 charging Ta Unpaired Pair microphone Link lost Re pair or un pair Charging Re pair or un pair Charged Re pair or un pair Paired Re pair or un pair Linked Turn off or un pair Microphone 5 charged Microphone 8 linked Pairing and un pairing of microphones is managed by the Microphone Management menu The Pair All Microphones Wizard guides the user through pairing of microphones to all channels and should be used when installing a new system or when all microphones on an existing system are being exchanged The wizard allows channels to be skipped during the process and may therefore be used to pair less than a full set of microphones to a system as well Selecting an individual microphone will open options based on the current status of the microphone on that channel Any channel with a microphone paired to it can unpair that microphone A microphone can also be re paired deleting the current pairing information on the base DSP unit and starting the pairing process The last option in this menu only appears when a paired microphone is
77. ng this information Export Law Assurances This product is controlled under the export regulations of the United States of America and Canada The Governments of the United States of America and Canada may restrict the exportation or re exportation of this product to certain destinations For further information contact the U S Department of Commerce or the Canadian Department of Foreign Affairs and International Trade The use of wireless devices and their accessories may be prohibited or restricted in certain areas Always obey the laws and regulations on the use of these products North America UPCS Usage Restriction 01 ELITEEXEC4 and 01 ELITEEXECS8 4 amp 8 channel systems respectively Due to the UPCS frequencies used this product is licensed for operation in the United States of America and Canada only European Union Usage Restriction 03 ELITEEXEC4 EU and 03 ELITEEXEC8 EU 4 amp 8 channel systems respectively Due to the DECT frequencies used this product is licensed for operation in the European Union countries and Australia only Eo revolabs Notice to European Customers CE Revolabs Inc 190 High Street Tonbridge Kent TNO 1BE UK Declare that for the hereinafter mentioned product model numbers the presumption of conformity with the applicable essential requirements has been approved in accordance with Council Directive 1999 5 EC Radio and Telecommunications Terminal Equipment and RoHS II
78. nnnnnnnnnnnnnnnnnnnnnn 21 SV SUC IY SOC a a E A E E E A E E A A E 22 Revolabs Executive Elite Audio ConnectionS i cccccccceececcccccccsscsssescccceeeeeeeeeeeeeeeeeeeeeeneeesesceeeseeeeeeeeeeeseaeens 22 Synchronizing Executive Elite units sissies ccciaisscnssssetsvassseisusis tenuis uusuandiniuscceabiiectianiiieitinadnssdinuinetiniineds 23 Front PANE WSET 1NMCETIACE cicssccsccstiecstavsdecacetanceadiecancecstconascensdeeansdunsueiuxtnancetinucssaundsacneteeussusenceancetnnes 26 Home 5 CPE CIWS wacsccaced eae saweseescceseeeetesssessecueanoedessaevedseechoavencacsndeanceawewnctieunssaveenseucedsateneeseaveresdsweatansaeecdsaveneseseeesuaie 27 Front Panel Menu UCC wiiccesvcssscsssivecenssssessavecvunsscebunstviewensusieasaeactunusseuuatsawsteuusscsbassvactudessuatiauateunesatsxieduaedsansed 31 Man Me A E A A A A 31 LOCH VY CD eaae Oi 37 COnNECtING To the local wep Ulsssiaisysissiaasn rgia ania Saanaa aandaa 37 PUS COMENSA O an tuneaeuissnssansicenseranuiaceisersntuseaiaosivests 39 Monno r ane nE E eE EEE EAEE EEE Ee EEO EERE EEEE EEEREN EEAO E EEE E E E 41 Mi ronnonc Ando PA E eyri 44 NUMO MINI MOE arai EEEE ENE EA TAEAE eR 46 OVC TOU ae E EE E E AT 63 Creating BEV OC lod ACCOUN saints cess cvedsavet cess tecscdssewtcauauss iran nN aa NANANA EEANN Saa NEA AEAN TS Eaa 64 revoCloud HOME csssssssscccccccsssssssceccccccssseececcccncceecsseseceneecensesseceneaeenssseeeeceeeneeenssseeeeenenneasesseeensanensssssseseennaengas 65 System nformation csssseeeee
79. o define microphone groups The main reason for microphone groups is to define a common mute behavior between the microphones therefore the name Mute Groups Beside a common mute behavior within the group the Web User Interface also allows to monitor and manage microphones within one group The web user interfaces allows creating mute groups and assigning of microphones to the different groups Different Base DSP units in the same cluster share with each other their mute group definitions See the description of the user interfaces earlier in this document on how to create clusters groups and assign microphones to these groups Each Executive Elite Base DSP unit and therefore every Base DSP cluster can have up to 10 mute groups within that cluster Delet mute groups that are no longer required in your installation Within the Mute Groups Executive Elite supports several mute types for the microphones allowing the user to select the mute behavior that best reflects their use case Unmute at Startup The Unmute at Startup setting defines the mute state of a microphone when it is turned on restarted or taken out of a charger base If this mode is selected all microphones in the group will unmute in these circumstances If it is not selected then all microphones in the group will start muted revo aos 94 Individual Mute A mute group that is set to Individual Mute allows each microphone to control its own mute behavi
80. onfiguration Ifthe problem continues please check if your computer has auto update disabled and or contact your administrator Once the driver is installed the front panel LCD will show an overlay with the IP address for the USB interface The IP address of the USB interface can also be found by visiting Main Menu System Information Network Information Network Information USB If the Executive Elite Base DSP unit is connected to the LAN you can also use a computer on the same subnet with no firewall in between to access the web UI interface The Elite system is factory pre configured for DHCP and will request an IP address from your DHCP server The IP address of the LAN interface can be determined through the front panel interface by visiting Main Bie revolabs 37 Menu System Information Network Information Network Information LAN Logon page Open a supported web browser on your Computer or laptop and type in the IP address of the Executive Elite Base DSP unit Once the web browser connects to the Executive Elite base DSP unit it will show the logon page asking for the system password The password for the local web UI and the front panel is shared and the factory default is 7386 If this password is changed either through the front panel or the web UI both interfaces will require the new changed password Login Maine Conf Room System 4 Executive Elite Login Maine Conf Room Sy
81. op Boundary Microphones enable multiple conference attendees to use a single microphone 1 Mute touch areas amp LEDs touch to mute un mute or pair the microphone LEDs provide visual status for mute un mute and pairing The omni directional microphone provides four mute touch areas and status LEDs one on each side of the microphone Any one of these touch areas may be used to mute and unmute the microphone 2 Charging connector connects to the charging pins of the Elite charging tray or crossover adapted 3 Battery door latch open the battery door using this latch 4 Rechargeable batteries replace batteries only with NiMH 2000mA rechargeable batteries Non rechargeable batteries or rechargeable batteries of a different type or lower charge might impact performance of the microphone and might cause harm to the microphone users or the environment Using non approved battery types will void the warranty on the microphones When replacing the batteries ensure that the batteries are placed in the correct way as indicated by the print in the battery cavity of the microphone 5 Battery charge status LED under the screen warns for low battery The LED will turn yellow when there are 4 hours of talk time remaining and red for the last two hours of charge revo abs 81 To use the Elite Omni Directional Tabletop Microphone 1 Remove the microphone from the Charger Base The microphone will automatic
82. or Touching the mute area of one microphone will toggle that microphone between muted and unmuted state but will not affect other microphones in the group TableTop mute The TableTop Mute option enables all tabletop microphones directional omni directional gooseneck to mute all microphones in the group when a mute area is touched Once another tabletop microphone mute area is touched all tabletop microphones will un mute and all Wearable microphones TA4 adapters and XLR adapters will return to their previous state Wearable microphones XLR adapters and TA4 adapters will be able to individually mute at that time as described in the Individual Mute setting Push to Talk In a group that is set to Push to Talk all microphones are muted unless the mute area is touched While it is touched the microphone is in the unmuted state Each microphone controls its own mute behavior only and touching the mute area of one microphone will have no effect on other microphones in the group Because the touch area of a microphone in a Push to Talk group must be held continuously for the microphone to remain unmuted holding the touch area will not turn off the microphone Instead the microphone must be turned off through the Web UI through the Front Panel through the room control API or by returning it to the charger base Chairman Microphone In each microphone group one microphone can be designated as a chairman microphone If a
83. ort Restart All Components Restart Warning This will overwrite all configurations on this Restore Factory Defaults device It is recommended that you back up a copy of configurations first by choosing the Export option Warning This will delete all configuration settings on this above device It is recommended that you back up a copy of configurations first by choosing the Export option on the left Restore Factory Defaults On the right hand side of the page the components of the Executive Elite can be restarted independently or in groups Restart Base Digital Signal Processing Unit will restart the base and the remote antenna Restart Remote Antenna Receiver will force the Remote Antenna only to restart Restart All Microphones forces all currently linked microphones to restart Finally Restart All Components forces the Base DSP unit the Remote Antenna and all linked Microphones to restart Restore Factory Defaults resets all settings in the Base DSP unit to the factory defaults as listed in the table below A Reset Factory Defaults will restart the initial installation dialog to collect system name region and cluster revolabs 57 information Cloud registration information is not deleted as part of the system reset If a system was registered before the cloud registration window will not open Microphone pairing information is also not affected by restoring Factory Defaults previously paired microphones
84. ource software in the Executive Elite products and the respective licenses under which these software packages are used The different software licenses and license templates can be found on the internet at the following addresses January 2014 Oracle http www oracle com us corporate contracts license service agreement index html http www astro caltech edu mcs tecla LICENSE TERMS License j revolabs 98 The specific Open Source software packages used in the Executive Elite product are Name Version License Type mea USB Audio 2 0 XS1 L2 Software Source code for these open source software packages can be obtained by contacting Revolabs at support revolabs com Eo revolabs Troubleshooting Accessing the Web UI through the Front Panel USB If the network settings are configured incorrectly it can cause an Executive Elite system to become disconnected from the network making access to the Web UI over the LAN impossible However the Web UI can still be accessed from the USB port on the front panel of the Elite Using a micro USB cable connect the computer you wish to use with the front USB connector of the Executive Elite DSP base Driver software might need to be installed on your computer on first connection Once the driver is installed and available a popup on the Front Panel LCD gives the static IP Address for the USB web connection Open a web browser and enter the IP Address then log
85. p ch lt channel number gt lt group name gt val chairmanmicgroup lt group name gt lt mic id gt val chairmanmute ch lt channel number gt lt O 1 gt 70 val chairmanmute ch lt channel number gt lt 0 1 2 gt chairmanmute set chairmanmute ch lt channel number gt lt 0 1 2 gt get eq ch lt channel number gt set eq ch lt channel number gt lt eq1 gt lt eq2 gt lt eq3 gt lt eq4 gt groupmutetype get groupmutetype lt group name gt esroupmutetype set groupmutetype lt group name gt lt O 1 2 gt groupstandbymode get eroupstandbymode lt groupname gt eroupstandbymode set eroupstandbymode lt groupname gt lt O 1 2 gt legacymode get legacymode mastermutemicgroup get mastermutemicgroup lt group name gt mastermutemicgroup set mastermutemicgroup lt group name gt lt 0 1 gt set micgain ch lt channel number gt lt gain value gt get micgain ch micgain micgain lt channel number gt Eo revolabs Configure the given channel s chairman mute state O all unmuted 1 members muted 2 all muted Retrieve the four EQ values associated with the given channel Configure the four EQ values associated with the given channel EQ range 10 to 10 db Retrieve group mute type O Individual mute 1 Tabletop mute 2 Push to talk Configure group mute type O Individual mute 1 Tabletop mute 2 Push to talk Retrieve group s
86. push towards the back of the microphone to open the battery compartment 3 Li Ion rechargeable battery can be taken out and replaced after opening the battery door Replace batteries only with Revolabs approved rechargeable batteries 4 Battery charge status LED warns for low battery When there is approximately 2 hours of talk time remaining this LED will turn yellow When the LED turns red there is approximately 1 hour of charge remaining Mute LED visual status for mute un mute and pairing Mute button press to mute un mute and pair microphone Clip used to attach adapter to clothing or a belt ONO Charging connector connects to the charging pins of the Elite charging tray 9 TA4 Mini XLR connecter use to connect a lapel or over the ear microphone to the TA4 adapter See picture below for the wiring of the TA4 adapter ITV A a 3 MIC ING MIC IN ere Note Pins 2 amp 4 are not connected oL revolabs 89 NOTE Use only microphones compatible with the wiring of the TA4 adapter NOTE The TA4 adapter provides 2 7 volts of phantom power To use the Elite Wireless TA4 mini XLR Adapter 1 Remove the mini XLR Adapter from the Charger Base 2 Attach a microphone to the top of the adapter and clip the end to clothing or a belt Make sure that the microphone and adapter are attached securely 3 After positioning the microphone at the distance
87. r View 13 14 revo abs Power In Receptacle 100 240 VAC 50 60 Hz Remote Antenna Connector PoE enabled AVB network connector LAN network connector Serial port for room control interface USB connector future use Euroblock connector grey Executive HD compatible synchronization bus Euroblock Connectors analog audio in black and audio out green microphone channels 1 4 Euroblock Connectors analog audio in black and audio out green microphone channels 5 8 only on Executive Elite 8 microphone systems 17 The Revolabs Executive Elite Base DSP Unit is designed to be installed into a standard 19 AV rack using the attached rack ears Screws are not provided a J Fail fa ooodoooo l D Executive Elite F z oO revolaos 18 Remote Antenna Receiver The Remote Antenna Receiver consists of two pieces the mounting plate and the Antenna housing The Remote Antenna Receiver is installed similar to a wireless access point Best locations are high on the wall facing into the room in which the microphones are located Each Remote Antenna Receiver supports one Base DSP Unit If more than one Base DSP Unit is installed for a room e g more than eight microphones are required several Remote Antenna Receivers will be installed in this room It is best to install the receivers on the same wall facing into the room spaced at least 12 inches 30 cm The Remote Antenna Rece
88. r information on how to set these parameters Selecting Synchronization Method Choosing a Synchronization method may be done through either the Web UI or the Front Panel LCD From the Front Panel the synchronization mode may be selected from the System Clock submenu under System Settings Once the mode is selected the interface will automatically prompt the user with a choice of Internal or External clock mode Only one Internal can be set for any sync mode this Eo revolabs 23 device will be the clock source to all synchronized systems All other devices need to be set as External and use the clock signal of the Internal Through the Web UI synchronization mode can be set on the System Configuration page In the table on the bottom left of that page are two dropdown menus The first is for the synchronization mode and the second for setting the system as Internal Primary on the Executive HD or External Secondary Mode on HD clock mode Synchronization Bus The synchronization bus allows connecting several Executive Elite Base DSP units together to manage the clock between the systems The Synchronization bus also allows synchronizing Executive Elite Base DSP units with Executive HD receivers in the same vicinity While the synchronization bus in Executive HD installations also managed group mute control this capability is handled differently in Executive Elite When installed together with Executive HD systems the bus wi
89. ral Info displays the System Name the serial number and the base firmware version The Remote Antenna Receiver section shows the antenna s MAC Address DECT IDs for the 2 Executive Elite 4 microphone system or 4 Executive Elite 8 microphone system basebands antennas and the antenna firmware version This section also includes information on whether the antenna is currently connected or not Across the middle of the page microphones are listed by channel from 1 to 4 or 1 to 8 based on the number of microphones supported by the system with their microphone type DECT ID and the current firmware version provided A channel with no microphone paired will show no information Connected Units in Cluster shows the IP Address of any other Executive Elite base DSP units in the subnet that share the same cluster name The cluster name can either be set during the initial setup wizard or on the System Configuration page described in the next section The Base Digital Signal Processing Unit table displays the Base s IP Address MAC Address and the static IP Address used by the USB port on the front of the base Any changes made to this information through the Network Management page will be displayed here AVB Information shows the system s AVB MAC Address AVB sync mode the IP Address of the Internal or clock master and if the link is up or down If revolabs 50 AVB is not connected the Link S
90. register this system for online access please enter the email address Create New Account and password for the online account you have previously set up Email Address Password Forgot Password lt Back Register Now Remind Me Later Don t Remind Me The New System Configuration page allows registering the Executive Elite with an existing revoCloud account If a registered user email and password are provided the Elite Base DSP unit establishes communication with the Cloud Server and adds its information to the system registry on the server The Create New Account button will bring up a registration window to create a new account on the Cloud Server Further details on this process are provided in the revoCloud section of this document If the Elite System will not be registered with the Cloud Server at this time Remind Me Later will close the window and remind the user to register after the next login Do not Register will skip the registration and will not remind the user to register the system later The Elite System can always be registered at a later time through the local management interface After leaving the System Registration page a popup will appear asking if microphones should be paired now or later Microphone Pairing X 1 Would you like to pair microphones now i PoirNow ii Later If the microphones are ready to begin pairing a short pairing wizard will walk the instal
91. ry ch lt channel number gt lt percentage gt notify status_change_mic ch lt channel number gt lt status gt notify status_group_mute lt group name gt lt group mute state gt val type Notify client the given microphone s battery status changes Notify client the given microphone s status changed O off 1 on 2 standby 3 charging 4 out of range 5 not paired 6 pairing 7 unpairing 8 updating Notify client the given group s mute status changed 8 group muted O group unmuted Mic battery status 1 25 2 50 3 75 4 100 Mic mute state O unmuted 1 self muted 2 muted 3 microphone off 4 microphone out of range 5 microphone charging Mic type 1 Lapel Wearable 2 Omnidirrectional Tabletop 3 Directional Tabletop 4 XLR Adapter 5 Countryman Adapter revolabs 75 Firmware updates Executive Elite Firmware can be upgraded two different ways An Executive Elite system registered to the revoCloud can be upgraded to the most recent build from the Cloud Support web page Select the system on the cloud webpage and click on Upgrade to latest build to immediately upgrade the system as described on page 67 Any system independent on whether it is registered on the cloud server or not can be updated through the Software Upgrade page of the local Web UI If the system is registered to the cloud server t
92. s Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help You may also find helpful the following booklet prepared by the FCC How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 revolabs Industry Canada Notice to Users Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement IC 6455A O1EXEC Revolabs Executive 8 Channel Base Station IC 6455A O1EXEC4 Revolabs Executive 4 Channel Base Station IC 6455A 01EXECMIC Revolabs Executive Tabletop Microphone IC 6455A O1EXECMICWR Revolabs Executive Wearable Microphone RF Exposure This equipment complies with FC
93. s and hold the Mute button for about 10 seconds until the LED turns solid red then release button The adapter can also be turned off from the local web UI or the room control interface In push to talk mode the adapter cannot be shut down using the mute button NOTE Do not place the XLR adapter into the Charging base while the handheld microphone is still attached Place only the adapter in the charging Base NOTE The XLR adapter does not provide phantom power Use only dynamic hand held microphones with the adapter If the adapters are placed too far away from the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or more from the Remote Antenna the connection will be dropped LEDs flash red yellow green yellow and the microphone will mute After 15 seconds the adapter will beep and will continue beeping every 30 seconds to indicating that it is out of range Move the adapter closer to the Remote Antenna and the connection will automatically be re established to its original state and the beeping will cease Otherwise the adapter will continue beeping until it turns off after about 15 minutes j revolabs 88 The Elite Wireless TA4 mini XLR Adapter for lapel and ear set microphones The Elite Wireless TA4 mini XLR Adapter allows small lapel or over the ear microphones to be used with an Executive Elite system 1 Earpiece jack accepts a 2 9mm earpiece plug 2 Battery door
94. sed as long as the antenna or base is not rebooted However only Average and Peak data will be calculated no graphical data will be provided for such times The red part of the scan represents the percentage of the RF that is currently in use the blue is RF space that shows noise but could be used by the Executive Elite system and green represents available RF space As each snapshot of the RF environment is added to the graph the average is calculated and displayed in a column beside it and the peak activity so far is displayed next to that The table to the right of the graph shows the number of additional microphones the RF Environment can support at either average or peak activity calculated for each of the Executive Elite s System Audio modes While the graph is set up to display information over a 10 minute period the longer the scan is allowed to run the better estimate it can provide on average and peak activity for the local RF environment Running the RF scan does not impact microphone functionality The scan can run while all microphones are being used with no impact on audio performance RF Power Automatic Power Scaling on off Maximum Power Level 0 20 ft 0 6 m X 0 20 ft 0 6 m 10 40 ft 3 12 m 30 75 ft 9 23 m 50 150 ft 15 45 m 150 300 f 45 90 m The power of the broadcast from an Executive Elite s remote antenna can be set from the RF Power menu The higher the RF power the further
95. standby mode state Set group standby mode 1 Enter standby O leave standby 2 toggle Retrieve the legacy mode setting value O Legacy mode off 1 Legacy mode on Retrieve the given group s master mute state O unmute 1 muted Configure the given group s master mute state O unmute 1 muted Set gain value in dB channel number 1 8 or A Get gain value in dB channel number 1 8 or A get eq ch lt channel number gt lt eq1 gt lt eq2 gt lt eq3 gt lt eq4 gt val eq ch lt channel number gt lt eq1 gt lt eq2 gt lt eq3 gt lt eq4 gt val groupmutetype lt group name gt lt O 1 2 gt val groupmutetype lt group name gt lt O 1 2 gt val eroupstandbymode lt sroupname gt lt 0 1 gt val groupstandbymode default 1 val legacymode lt O 1 gt val mastermutemicgroup lt group name gt lt 0 1 gt val mastermutemicgroup lt group name gt lt 0 1 gt val micgain ch lt channel number gt lt gain value gt val micgain ch lt channel number gt lt gain value gt 71 micstandbymode get micstandbymode ch lt channel number gt micstandbymode set micstandbymode ch lt channel number gt lt O 1 2 gt micstatus get micstatus ch lt channel number gt mictype get mictype ch lt channel number gt mutestatus get mutestatus ch lt channel number gt Retrieve mic standby status channel number 1 8 or A Set mic into standb
96. stem 4 Password Login Stay logged in fe After entering the password and clicking on the Login button the web interface will progress to the next page The checkbox on the bottom of the password entry form will prevent the Web UI from timing out during a period of inactivity The Web UI will still log out 60 seconds after the browser window is closed When selecting this option remember to log off through the web interface or close your web browser before leaving the computer E revo abs 38 First time usage When installing the Executive Elite Base DSP unit and opening the web interface for the first time the system will require some system wide settings that need to be made before the system becomes operational Webpages to make these selections will be opened first Revolabs Execute Elite New System Configuration 2 System Identification I Required System Name Country Region USA Canada This information is used to determine the correct radio frequency for your location Selecting a different region than yours might void the right to use the system If you are unsure about the region you are in you can look up information here or contact Revolabs support at support revolabs com Cluster Name 2 If this system is part of a cluster enter the cluster name If this is the first system in a cluster use this name when you configure other systems in the cluster Leave this field blank if this
97. submenu prompting the user to choose if the system will be Internal and share its clock or External and search for an external clock master After selecting Internal or External the base will reboot to apply the changes In the Admin Settings menu the standard password used on the local web UI and the front panel can be changed The user can also log out of the front panel from here revo aos 34 Audio Settings Audio Settings System Audio 1 System Audio 1 Standard Definition SD 2 High Pass Filter 2 High Definition HD 3 Low Pass Filter 3 Legacy Mode on off 4 Back Channel on off High Pass Filter Mic 1 High Pass Filter 1 Microphone 1 None 110 Hz 8 Microphone 8 140 Hz 175 Hz 220 Hz Low Pass Filter Mic 1 Low Pass Filter 1 Microphone 1 1 None 2 4000 Hz 8 Microphone 8 3 8000 Hz 4 12000 Hz The Audio Settings section allows changing audio properties of the Executive Elite system The System Audio submenu controls the partitioning of the available RF space controlling the number of bytes allocated to transport the audio data between microphone and the base DSP unit Standard Definition SD reserves less RF space per microphone channel reducing the audio quality slightly as a higher compression has to be used but allows more microphones to be used at the same time High Definition HD allocates more RF space per microphone channel increasing the audio quality but decreasing the nu
98. t microphone to the Default group To define the mute behavior for the active group select the mute behavior from the Mute Type drop down list 6 see page 94 for information on the different mute group options The Unmute at Startup checkbox 7 next to the Mute Type menu determines whether microphones start unmuted when linking to the base or muted Chairman microphones provide a separate level of control to one microphone in a group Independent of the selected mute group behavior the chairman microphone in any group can mute all other microphones in that group A chairman mute cannot be undone by the non chairman microphones The chairman has to unmute the group before the mute button on the other microphones can control the mute behavior again Chairman mute passes through three stages First the chairman mutes all microphones except itself Touching the mute area again all microphones in the group including the chairman are being muted The next touch on the mute area will unmute all microphones When the group is not in Chairman Microphone mute the microphones react as defined in the mute setting for the group To select a chairman microphone move the mouse to hover over that microphone and the chairman symbol will appear under the microphone Click on the chairman symbol to make that microphone chairman To remove chairman rights from that microphone click on the symbol again When selecting a microphone as the
99. tal Output The digital output shows VU meters for the output signal as provided over AVB No gain stage is offered for the digital output as it is assumed that the data will be further manipulated at the receiving component revo aos 45 Audio Management The Audio Management menu houses the Manage Groups and System Audio pages Manage Groups Microphone groups allow defining different mute behavior between individual microphones or groups of microphones Microphones in one Executive Elite System can be assigned to any number of microphone groups Each group can then be assigned a specific mute behavior for that group Using the Cluster concept mute groups can be extended across several Executive Elite Base units to include microphones from different systems To create mute groups across several Executive Elite units the Elite bases need to be connected to an IP network and to be part of the same subnet see page Error Bookmark not defined on how to set up clusters When adding an Executive Elite base DSP to an existing Cluster mute group names will be exchanged between the system that was added and the systems priviously in the Cluster ensuring that all systems in the cluster have the same mute groups NOTE Up to 10 Mute groups can be created within one Executive Elite base DSP or Cluster If several Executive Elite Clusters or non clustered Executive Elite Base DSPs are on the same network or using the same synchronizat
100. tatus will show Down and there will be no Master IP Address System Configuration The System Configuration page allows setting several of the system configuration values including system name cluster name and region Changes to any entry on this web page only take effect when clicking the Save button Leaving the page without previously saving changed information will discard the changes System Configuration Maine Conf Room System 4 2 System Name Maine Conf Room System 4 Language English Cluster Name Country Region USA Canada v Password Confirm Password Enable Telnet Server On off Front Panel Configuration Base Pairing Lock On off System Clock Clock Source Local v Clock Mode Internal T System Name allows changing the descriptive name under which a system is being identified It is recommended to select a name that helps identifying a system in the cloud web UI or in a cluster The Cluster name allows grouping several Executive Elite systems together for larger installations Executive Elite Systems using the same cluster name in a subnet share group and microphone mute information allowing common mute behavior to be defined across several Executive Elite systems Every Executive Elite base intended to be in that cluster has to use the exact same cluster name To remove a base from a cluster delete the cluster name and leave the cluster name field empty To make the Executive Elite base part of
101. te lt group name gt lt 0 1 gt O not tabletop mute 1 tabletop mute number gt for mic in specified number gt lt 1 2 3 4 gt channel fp set fp lt 0 1 gt Set front panel display val fp lt O 1 gt lock on or off O Off 1 On gain set gain ch lt channel Configure input gain val gain ch lt channel number gt lt 0 1 2 80 values 80 100 set the number gt 120 gt gain from 20 to O dB lt 0 1 2 80 120 gt values 101 120 will all set the gain 0 dB 1 modify gain by 1 E modify gain by 1 set gain to O number gt specified channel number gt lt 80 120 gt lock set lock ch lt channel Turns Mic Lock on or val lock ch lt channel number gt lt O 1 gt off number gt lt O 1 gt O Off 1 On Eo revolabs 13 lock get lock ch lt channel Retrieve Mic Lock for val lock ch lt channel number gt specified channel number gt lt O 1 gt set mute ch lt channel number gt lt O 1 gt get mute ch lt channel number gt Notifications Mute or unmute specified channel O Unmute specified channel val mute ch lt channel number gt lt 0 1 gt 1 Mute Retrieve mute state for val mute ch lt channel number gt lt 0O 1 2 3 4 5 gt The Executive Elite command regnotify will turn on notifications Notifications Notification Format mute_group_change mute_group_member_change mute_group_mute_type_change set_mute_status startup_unmute_
102. te electrical and electronic equipment The separate collection and recycling of your waste equipment at the time of disposal will help conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste for recycling please contact your local authority or where you purchased your product B revolabs 10 Safety Warnings e Follow the instructions in the Revolabs Executive Elite Installation and Operation Guide e Do not expose any of the Executive Elite components to water moisture or high humidity e Do not expose any of the Executive Elite components to extreme high or low temperatures e Do not expose any of the Executive Elite components to lit candles cigarettes cigars or to open flames etc e Do not drop throw or try to bend any of the components as rough treatment could damage them e Do not open the casings of any of the components of the Executive Elite system e Do not use any other accessories than Revolabs originals intended for use with this product Use of non original accessories may result in loss of performance damage to the product fire electric shock or injury The warranty does not cover product failures which have been caused by use of non original accessories e Only use the power adapters provided to connect the components to the electric mains e Do not open or try to mo
103. teries in fire Dispose of batteries in accordance with manufacturer s instructions and local regulations Pairing Wireless Microphones to Remote Antenna and Base DSP Station Pairing creates a link between the Elite wireless microphone and the Base DSP Unit through the Remote Antenna with a unique electronic serial number When the microphone and Base DSP Station have been previously paired the microphone will automatically try to connect link to the same Base DSP Unit whenever it is lifted from the Charger Tray NOTE New microphones in a system must be paired to the Base DSP Unit with each microphone assigned to a unique channel on the base unit NOTE The microphone needs to be in range of the Remote Antenna during the pairing process Pairing is done wirelessly the microphone communicates through the Remote Antenna to the Base DSP Unit during pairing A microphone that is not paired will be indicated by a cycling red green LED pattern A Base DSP Unit channel that is not paired to a microphone will not revolabs 91 show any activity on the channel LED and front panel LCD and will be shown as Not Paired on the web interfaces During pairing the microphone LEDs and the channel LED on the front of the Base DSP Unit will stay solid red Only one microphone can be paired to any single Base DSP channel at a time Any Base DSP Unit will protect against several channels pairing at the same time However if pa
104. to the antenna and the Base DSP unit There are several different microphone and microphone adapter types available with the Executive Elite Omni directional tabletop microphone Directional Cardioid tabletop microphone 12in Gooseneck tabletop microphone 6in Gooseneck tabletop microphone Wearable Presenter microphone and transceiver TA4 microphone adapter mini XLR and transceiver XLR microphone adapter and transceiver To transmit audio Microphones need to be paired to their receiver and antenna as described later in this document Finally you might have purchased additional components like the ceiling mount kit for the remote antenna receiver or the cross over adapter to install wireless tabletop microphones permanently or semi permanently on your tables Ee revolabs 16 Installation Base DSP Unit The Revolabs Executive Elite Base DSP Unit shown below in front and rear panel views provides the audio output of the wireless microphones and the management interfaces to administer the microphone system Front View 1 2 3 4 5 lea revalaas USB web access to local web user interface 2 Microphone status LEDs showing pairing and mute status 8 LEDs on the Executive Elite 8 microphone system 4 LEDs on the executive Elite 4 microphone system 3 Front panel LCD displaying system information Navigation buttons controlling content of front panel LCD display 5 On Off switch 6 7 8 9 10 11 12 13 14 Rea
105. to the Charger Base or press and hold the Mute button for about 10 seconds until the LED turns solid red then release the button The microphone can also be turned off from the local web UI or the room control interface Note that in push to talk mode the microphone cannot be shut down using the mute button If the microphones are moved out of range of the Remote Antenna depending on the RF power setting this can be 300 feet 90 meters or more from the Remote Antenna the connection will be dropped the LED flashes red yellow green yellow and the microphone will mute After 15 seconds the microphone will beep and will continue beeping every 30 seconds to remind the user to return the microphone to the conference room If the microphone is moved back into range of the Remote Antenna within 15 minutes the connection will automatically be re established to its original state and the beeping will cease If not the microphone will turn off revolabs 79 Adjusting the Volume on the Wearable Microphone Earpiece To change the volume on the Wearable microphone earpiece use the dial on the earpiece wire LOUDER Microphone a Earpiece End End A SOFTER Turning the dial as shown in the figure will increase decrease the volume Use the attached clothing clip to secure the earpiece wire Ye revo aos 80 The Elite Omni Directional Wireless Tabletop Boundary Microphones The Elite Omni directional Wireless Tablet
106. top Gooseneck Microphone Revolabs Elite Universal Wireless Adapter for Handheld Microphones XLR adapter Revolabs Elite Wireless TA4 Adapter mini XLR adapter NOTE Before using microphones they must be paired to the Base DSP unit and Remote Antenna Each microphone is assigned a unique channel on the Base DSP unit See pairing instructions below on how to pair microphones NOTE Replace batteries only with Revolabs approved rechargeable batteries Non approved batteries or rechargeable batteries might impact performance of the microphone and might cause harm to the microphone users or the environment Using non approved batteries will void the warranty on the microphones When replacing the batteries ensure that the batteries are placed in the correct way revolabs 77 The Elite Wearable Wireless Microphones The Revolabs Elite Wearable Microphones shown in the following figure can be worn on the user s shirt lapel blouse or on a lanyard They provide high quality full duplex audio between the users and the conferencing or audio system 1 Earpiece jack accepts the 2 5mm plug of the earpiece 2 Battery door push towards the back of the microphone to open the battery compartment 3 Li Ion rechargeable battery can be taken out and replaced after opening the battery door 4 Mute LED visual status for mute un mute and pairing 5 Battery charge status LED under the screen warns for
107. vironment with both Executive HD and Executive Elite systems as Executive HD Systems do not support AVB The Setup for ABV sync is through an AVB capable switch Once the Executive Elite synchronization mode is set in the Web UI or Front Panel to AVB select Auto as the Clock Mode Through the AVB networking software set up a network of elite systems where at least one system is a Talker and the other systems are Listeners to that system The architecture also allows for communication chains where one Elite is set up as a Listener to a system in the chain and as Talker to systems further down in the chain OTA Synchronization Executive Elite systems have the ability to synchronize with other Executive Elite systems in radio frequency range using over the air OTA synchronization This synchronization method does not require any wiring between Executive Elite Base DSP units In OTA mode systems exchange synchronization information using radio signals therefore allowing systems in vicinity to auto synchronize To enable OTA synchronization select OTA as the Clock Source 1 OTA Synchronization will be available starting with Executive Elite Software version 1 2 revolabs 25 Front panel user interface The Front panel user interface is one of four interfaces available to manage an Executive Elite system The others are the local web UI the Cloud Server Web UI and the CLI room control interface and are described lat
108. vo avs 21 System set up Once the Remote Antenna Receiver has been connected to the Base DSP unit connect that unit to the power mains and turn the switch on the front of the unit to 1 from O The unit will now power up You will see messages on the front screen providing information until the unit is operational Once the Screen with the VU screen is shown and the Antenna symbol is constant the system is operational For additional system configuration instructions see later sections describing the different user interfaces in this manual Revolabs Executive Elite Audio Connections The Executive Elite Base DSP unit offers three different ways to deliver the audio from the microphones to post processing equipment as well as to provide back channel audio to the microphones While all three audio output paths will be active at all times only one of the back channel audio paths can be active The user interfaces allow selecting which path should deliver the audio back to the microphones Analog Audio The back panel of the Executive Elite DSP eight channel base unit provides eight 3 5mm Euroblock inputs and eight 3 5mm Euroblock outputs the four channel unit provides four input and four output connectors providing access to each channel s audio signal The Euroblock connectors included in the package are designed for easy wiring The three terminals from left to right correspond to positive negative and shield
109. word are required Optionally a User first and last name may be entered as well The email address will be required for future logons to the revoCloud or to register Executive Elite systems to the cloud After the required information has been entered please read and accept the Terms Conditions and privacy Policy enter the CAPTCHA code and submit the application Create New Account Required Organization Name First Name Last Name Email Address Password Confirm Password 4 2 Enter Code Try another code Select to agree to the Terms Conditions and Privacy Policy Create Account Cancel After the application has been submitted an activation email will be sent to the email address specified This email can be re sent by logging into the revoCloud using the email and password from account creation and selecting the Re Send Verification Email option on the welcoming page E revolabs 64 The link provided in the verification email will expire 24 hours after the email was sent so please verify the account as soon as possible Once you click on the link provided in the verification email you will be forwarded to the revoCloud web page where you will see the verification message Revolabs revoCloud l Thank you Your email has been verified Log in to get Revolabs revoCloud allows remote monitoring and managing of canine Revolabs Executive Elite installations If your organization do
110. x 25 4 x 4 4 cm 0 45 kg 7 9 x 7 9 x 2 9 cm 134 g Directional Tabletop 3 125 Xx S129 x 1 7 5 in 5 0 0z Directional Tabletop oero zaaem tag 6in Gooseneck 3 125 x 3 125 x 1 75 in 6 8 oz 1 9 x 7 9 x 4 4 cm 192 g with a 6 in gooseneck 12in Gooseneck 3 125 x 0 129 x 1 51in 7 7 OZ 1 9 Xx 7 9 x 4 4 cm 219g with a 12in gooseneck E pe 7 6 x 3 2 x 1 9 cm 35 g 8 6 x 7 9 x 2 9 cm 141 g Pee revolabs 101 Microphone Polar Patterns Elite Omni Directional Wireless Tabletop Microphone revo aos 102 Index Adjusting the Volume 80 AVB Audio 17 23 Ferrite 21 Input Connectors 22 Microphone Charging port 78 87 89 Earpiece Jack 78 87 89 LED Display 78 87 89 Mute Button 78 87 89 Pocket Clip 78 87 89 Microphones 78 Pairing 91 revo abs Polar Patterns 102 Safety Information 6 Synchronizing 23 AVB Synchronization 25 OTA Synchronization 25 Synchronization Bus 24 Synchronization method 23 System Components Base Station 14 Microphone Charger Base 14 Wireless Boundary Microphone 81 83 XLR Microphone Wireless Adapter 89 103 Revolabs Executive Elite Installation and Operation Guide O1 EXECELITEGUIDE EN August 2014 Rev 1 0 5 revolaos 104
111. y mode 1 Enter standby O leave standby Retrieve the given microphone s current status O off 1 on 2 standby 3 charging 4 out of range 5 not paired 6 pairing 7 unpairing 8 updating Retrieve the given s microphone s type O Wearable 1 Omni 2 Directional 3 XLR 4 Mini XLR 5 Gooseneck 10 Handheld 11 unknown Retrieve the mic mute status value is a comma delimited string lt mute gt lt mute type gt lt mute lock gt val micstandbymode ch lt channel number gt lt 0 1 gt val micstandbymode ch lt channel number gt lt 0 1 gt val micstatus ch lt channel number gt lt status gt val mictype ch lt channel number gt lt type gt val mutestatus ch lt channel number gt lt mute gt lt mute type gt lt mute lock gt regnotify Regnotify Register to listen to regnotify system notifications outputgain get outputgain ch lt channel number gt outputgain set outputgain ch lt channel number gt lt output gain gt outputlevel get outputlevel ch lt channel number gt T revolabs Retrieve the given channel s output gain Configure the given channel s output gain output gain range 20 to 5 dB Retrieve the channel output level channel number 1 2 8 A O mic level 1 line level val outputgain ch lt channel number gt lt output gain gt val outputgain ch lt channel number gt
Download Pdf Manuals
Related Search
Related Contents
Bedienungsanleitung D & GB FT 560132 Boldair gel destructeur d`odeurs Fleur de coton Инструкция по эксплуатации リニアアクチュエータ用ドライバ LAD-01C-012 取扱説明書 Kalorik - Team International Group Coffeemaker USK CM 17408 User's Manual Copyright © All rights reserved.
Failed to retrieve file