1. BLACK BOX 2007 Alll rights reserved Black Box Corporation Black Box Corporation 1000 Park Drive e Lawrence PA 15055 1018 e Tech Support 724 746 5500 e www blackbox com e mail info blackbox com PRO SWITCHING SYSTEM I i oe oe oe ee joa 180 oa L180 oa C1 80 oa 18 g 2 oe Le TE eee oa 8ojoa 80 oo oc000 20000 nnn nannan prr AA Bme ol UN j ES i i En a AN o o i i ll pono a FNM NCA SUPPLY a el eo ae Control hundreds or thousands of devices from a single ASCII terminal or PC Key Feat E E shueslaamietene Ey Ed TES Miers switchable circuitsis a single console This means of the card edge interface for the gt Chassis mounted easy with the Pro Switching control is an alternative cards you plan to add The rear hi nd h System II PSSII from Black Box to connecting multiple multiport plate of the chassis has three rows swite ing and patch This innovative system consists KVM switches when you want of DB25 EIA connectors Use them ing system for RS 232 of rackmount modular components to manage hundreds of CPUs to attach the A B and Common JOU A Z1 f that provide an economical an ne console can modem sides of your data cables RS 530 X 21 and V35 that provid ical and One PSSII consol modem sides of your data cabl data communications reliable means to manage support 32 000 switchable circuits C
2. enables you to connect a data line monitor device when you want to passively monitor certain lines The interface s parallel wired connectors are also used to daisychain two or more PSSII chassis Modules for the system For your various interface requirements we offer a number of modular cards also called circuit cards that can be installed in a PSSII chassis Each card is a single switchable circuit between your data terminal equipment DTE and data communications equipment DCE and feature circuit status display and alarm definition detection and reaction The cards are equipped with three ports that link to A B and Common paths These paths connect to the equipment cables attached in at the chassis rear You can switch paths for instance when you need to reroute a circuit from an attached device that has failed to a device or circuit that s operational To switch press a button on the mounted card LEDs inform you of your selected switch position Each card has four manual patch cavities Three of these provide intrusive access to the A B and Common modem sides of the switchable circuit The fourth cavity provides bridged non intrusive access to the Common modem side RS 232 RS 530 X 21 and V 35 Front Interface Cards SM906C SM909C feature a switchable A B circuit a common RS 232 or V 35 cable connection plus signal monitoring LEDs You can mix match and install up to 16
3. Software makes on switching capabilities inthe system all slave connections cards which we offer as Front I with a simple command from an The PSSII chassis Interface Cards or Universal Serial screen control a snap attached console We even offer a Atthe heart of the system isthe Cards Each module passes one gt Multiple programmable Contact Closure Card that lets you chassis Choose the SM900A for switchable data circuit The PSSII chassis also has a alarms alert you to use a programmable logic RS 232 RS 530 X 21 or V 35 network conditions controller PLC to direct your communications For V 35 only use _ control communications interface circuit switching the SM901A and two test equipment interfaces gt Dual power options Daisychain up to 9901 chassis Each chassis has 18 mounting The latter two connections enable 12 18 2007 25900 together to control and manage 158 416 A B interface cards from slots with card guides and a backplane PC board that provides you to perform interactive test continued on page 2 The front and back views of a Pro Switching System Il chassis All modules mount in a Pro Switching System II chassis for installation in a standard 19 inch rack The chassis includes a six foot 1 8 m AC power cord Standard AC voltage is 115 or 230 volt input The redundant front loaded power supplies to be ordered separately provide DC voltage power to the chassis The Man
4. the LED display and to a DB25 I A interface on the chassis while the other provides a straight through connection to the Monitor interface connector Other PSSII components For using external test equipment with your Pro Switching System II order an optional 6 foot 1 8 m Test Cord The RS 232 version SM917 attaches the system to RS 232 or RS 530 equipment while the V 35 model SM918 attaches the system to V 35 equipment For standard nonintrusive testing you would run the cord from the bottom Monitor port patch cavity on a PSSII chassis to the DB25 or M 34 connector on your test equipment You can also use the Test Cords for intrusive testing that breaks the normal signal paths and routes the Port A or B or modem port signals to the external equipment You ll also need to equip your chassis with one or two Power Supply Modules SM950A or SM950A 220 Using two supplies makes your system more reliable if one module fails the other kicks in to keep the PSSII operating as normal Failure of either Power Supply Module will trigger a console alert although one module can provide enough power to a full chassis If you choose to use only one Power Supply Module be sure to order a Blank Cover for an Unused Power Supply Slot SM911C This is a protective metal strip that fits over the empty slot at the rack s rear and helps keep the chassis internal parts free of dust and other particles We also offer covers for
5. 32 TIA 561 8 wire RS 422 10BASE T or Token Ring up to 16 Mbps applications It can also be used to switch private T1 or E1 circuits not connected to the public telephone system With its latching relay feature the Universal Serial Card forwards all traffic in the event of a power failure and when used as a copper path operates independent of speed and protocol And there s no complicated programming As with the Front Interface Cards the Universal Serial Cards install in the front of the PSSII chassis and can even be mounted alongside the Front Interface Cards In a daisychain configuration you can put up to 16 Front Interface or Universal Serial Cards in each slave chassis The master chassis can be populated with up to 16 of these cards plus one Terminal Display Card Management cards For managing the chassis you ll need either a Management Control Card or a Terminal Display Card The Management Control Card SM902C or SM904C provides continued on page 3 continued from page 3 the logical bridge between the interface cards and the console generated commands Order the SM902C card for the SM900A chassis and the SM904C card for the SM901A chassis The Management Control Card supports console controlled data circuit alarming and includes a full array of LED signal status indicators and voltage test points With the card switching commands are received from the PSSII and relayed to the appropriate r
6. Cards RS 232 RS 530 X 21 V 35 V 35 Only and cards Front Interface Cards Universal Serial Cards RS 232 DB25 DB9 Serial DB15 Serial RJ 11 4 Wire RJ 45 8 Wire SM903C SM905C For manual and contact closure switching order Manual Contact Closure Card For empty slots order Blank Cover for an Unused Interface Slot for an Unused Power Supply Slot SM910C SM911C For connecting test equipment order Test Cords for DB25 for V 35 You may also want to order cable Category 5 Patch Cable 100 MHz 4 Pair Straight Pinned PVC Beige EVMSL05 0010 RS 232 Cable 25 Conductor 10 ft 3 m ECM25C 0010 V 35 Interface Cable 10 ft 3 m Male Male You may also need Modular Adapter Kits EYN450 0010 MM DB25 Male lt gt RJ 11 Female 4 or 6 Wire DB25 Male lt gt RJ 45 Female 8 Wire
7. ackmounted circuit cards These commands can be for individual circuits all circuits within arack or specific circuits that are part of a user defined circuit group whether they originate from a real time console entry or they re generated automatically when an alarm occurs If you re looking to configure the chassis from various locations while using an attached ASCII terminal you ll need the Terminal Display Card available for the RS 232 RS 530 X 21 V 35 chassis SM903C or V 35 only chassis SM905C With this card you can program the system to switch circuits ata specified time automatically This is a particularly useful capability when for example you need to redirect incoming calls at the office at a certain time of the day You can also use the Terminal Display Card to control a group of the circuit cards in a gang switch capacity The Terminal Display Card package includes the DB25 to RJ 45 card an RJ 45 to RJ 45 cable and a DB25 to RJ 45 adapter Management software The Management Control Software enables the PSSII to be configured to place outgoing calls and receive incoming calls from sites equipped with one or more PSSII chassis What s more the software provides you with the ability to examine any portion of your enterprise network at any desired level of detail In addition the utility advises you of any major occurrence anywhere within the network The software s interface displ
8. agement Control Card also to be ordered separately contains LEDs that indicate signal status of any interface patched to the control module cavity from a patch cavity The LEDs illuminate with a positive voltage such as a data space or a control signal high Next to each LED are voltage test jacks 2 Power Supplies 1 Management Control Card Slot is also used for Terminal Display Card 16 Front Interface Cards Slots are also used for Universal Serial Cards EQUIP A 15 EQUIP A 14 EQUIP A 13 EQUIP A 12 o lt 4 a e D EQUIP B 16 EQUIP B 15 EQUIP B 14 EQUIP B 13 EQUIP B 12 MODEM 16 MODEM 15 MODEM 14 MODEM 13 MODEM 12 EQUIP A 11 EQUIP A 10 EQUIP A 9 EQUIP A 8 EQUIP A 7 EQUIP A 6 a AE EQUIP B 9 EQUIP B 8 EQUIP B 7 EQUIP B 6 EQUIP B 11 EQUIP B 10 MODEM 11 MODEM 10 MODEM 9 MODEM 8 MODEM 7 MODEM 6 EQUIP B 5 EQUIP A 5 MODEM 5 EQUIP A 4 EQUIP A 3 EQUIP A 2 EQUIP A 1 CONTROL IN OUT VATEST EQUIP B 4 EQUIP B 3 EQUIP B 2 EQUIP B 1 MODEM 4 MODEM 3 MODEM 2 MODEM 1 MONITOR continued from page 1 module communications and test functions You can use the interface labeled I A for instance to connect a basic error rate BER tester or a protocol analyzer In addition to BER tests you can conduct protocol simulation block error rate BLER tests or error free seconds EFS tests The other test interface labeled Monitor
9. ards seat in the chassis from RS 232 V 24 V 35 X 21 and RS 530 in 2000 racks if you install 100 the front and their data connectors gt es data interfaces With this chassis racks at each of 20 sites In this plug easily into the cable g mounted switching and patching setup each site would contain one connectors without disturbing any switching an d switching and patchi h site would contai ithout disturbi patching or for switch system you can switch individual master rack which in turn would cable bundles attached at the only capabilities circuits all 16 circuits in a chassis support up to 99 slave chassis chassis rear The first slot holds gt Daisychain up to 9901 or a group of circuits via remote And you re not limited by a type the unit s Power Supply Modules full a l ne haesia console commands or upon an of cabling that can be used to order separately and the slot uny p a a d cnass alarm automatically connect the console to the master adjacent to itis for installing an to control and manage You can also switch manually chassis it can be local hard wired optional Management Control Card up to 158 416 A B Use front panel buttons to switch cabling a dedicated link or even or Terminal Display Card interface cards individual circuits or to gang a dialup link although you must use The chassis other 16 slots gt Management Control switch Or you can disable manual hard wired local cabling for can accommodate up to 16 circuit
10. ays on screen alarm conditions with a date and time stamp A color coded signal also shows the status of any circuit in the network and you can view signal status for an entire chassis The software s Circuit Configuration menu is the way you assign circuits to and from a group which is defined as a logical collection of circuits without regard to their location within the Pro Switching System II All switchable circuits within a specific group can be switched by either console command or automatically upon alarm Manual Contact Closure Card To provide both manual and contact closure gang switching capabilities to your system order the Manual Contact Closure Card SM916C This card enables you to patch a programmable logic controller PLC to the straight through Monitor interface connector on the chassis The PLC in turn is used to switch all circuits in the chassis from A to B and back again automatically Not only can you use the card with a PLC to close contacts but you can disable specific cards seated in the chassis using the card s DIP switches To manually reverse all switch positions in the master chassis you need only to press a lamp test button at the top of the card Unlike other cards designed for the PSSII the Manual Contact Closure Card does not support terminal or PC management It has a signal status LED display and two patch cavities The upper cavity provides a straight through connection to
11. cards in the chassis With up to nine alarm options each RS 232 RS 530 and V 35 circuit can be individually configured for up to a maximum of eight alarms on the presence or absence of Physical Layer signals And each X 21 circuit can be individually configured for up to six programmable alarms If you don t require patching capabilities but want economical A B switching plus transfer speeds of 10 Mbps within your PSSII order Universal Serial Cards SM930C SM934C These cards support RS 232 V 35 RS 530 X 21 10BASE T and analog RJ 11 or RJ 45 communications They differ only in the interface adapters shipped with them except for the SM930C which is designed to link to the chassis three DB25 connectors and therefore requires no adapters The SM9300 is a universal DB25 model that s suitable for RS 232 or RS 530 switching applications The SM931C has three DB25 male to DB9 female adapters It s ideal for RS 232 TIA 574 IBM PC COM port switching applications The SM932C has three DB25 male to DB15 female adapters and is suitable for X 21 switching The SM933C has three DB25 male to RJ 11 female adapters and is suitable for 4 wire RS 422 applications or can be used to switched telephone circuits not connected to the public telephone system The SM934C which features RJ 45 connectors that are RJ 48 compatible and are unkeyed includes three DB25 male to RJ 45 female adapters It s suitable for RS 2
12. unused circuit card slots in the rack As with the SM911C the Blank Cover for an Unused Interface Slot SM910C includes screws for securing it to the chassis All empty module slots on the chassis should be filled with these blank panels Doing this will help to prevent damage from occurring to the installed modules and the chassis components Software System Requirements e Pentium 1 or better processor e CD ROM drive e An available serial port for Pro Switching System II connections to one or more sites Additional serial ports are necessary if additional sites are to be supported without serial port sharing NOTE lf additional serial ports are to be added please call Black Box Tech Support e 4 64 or more MB of RAM e Windows 95 98 or Windows NT Windows 2000 and Windows XP are not supported Specilications Data Format 8 bit data 1 stop bit no parity Management Controls Terminal control Send Data Receive Data Serial Clock Transmit Serial Clock Receive Request to Send Data Terminal Ready Data Carrier Detect Data Set Ready GUI control Send Data Receive Data Serial Clock Transmit Serial Clock Receive Request to Send Data Terminal Ready Data Carrier Detect Clear to Send ITEM Management Method Via ASCII terminal or software Programmed Alarms RS 232 RS 530 V 35 Send Data Receive Data Serial Clock Transmit Serial Clock Receive Request to Send Data Terminal Read
13. y Data Carrier Detect Data Set Ready Clear to Send X 21 Transmit Data Receive Data Indicate Control Signal Element Timing Byte Timing Protocols Transparent Speed Terminal control 1200 2400 4800 or 9600 bps 19 2 kbps GUI control 1200 2400 4800 or 9600 bps CE Approval Yes Interface SM900A RS 232 RS 530 X 21 V 35 SM901A V 35 Connectors SM900A 48 DB25 F 3 per circuit 2 DB25 F for monitor 1 DB25 F for I A test 1 DB25 F for control in out SM901A 48 M 34 F 3 per circuit 2 DB25 F for monitor 1 DB25 F for I A test 1 DB25 F for control in out Ordering Information CODE ITEM Operating Environment Temperature 32 to 104 F 0 to 40 C Humidity 10 to 80 noncondensing Power 110 220 VAC 60 50 Hz internal with IEC 320 connector chassis can hold 2 front loaded power supply modules Size 7 H 4U x 19 W x 14 D 17 8 x 48 3 x 35 6 cm Weight SM900A 29 Ib 13 2 kg fully loaded SM901A 39 Ib 17 7 kg fully loaded CODE First order the chassis for your application Pro Switching System II Chassis RS 232 RS 530 X 21 V 35 next order one or two power supplies Power Supply Modules 220 VAC SM950A SM950A 220 then select either a control card Management Control Cards RS 232 RS 530 X 21 V 35 V 35 Only SMg02C SM904C or a display card for your master chassis Terminal Display

Download Pdf Manuals

image

Related Search

Related Contents

日識あり - 株式会社エフ・エム・アイ  LA SIGNALÉTlQUE EN BIBLIOTHEQUE  Samsung SL-M2026 Manual de utilizare  Samsung 24" minimalistický LED monitor s kovovým stojanom Užívateľská príručka  Manual for Avois FXO Gateways  MANUEL D`UTILISATION POUR CODEUR Profibus DP  3710 Mycoplasma suis1  Manual do Usuário - CONRAD Produktinfo.  Méthode de controlling des soins sylvicoles en forêt protectrice  System and method for managing data originating from and  