Home
Avaya MX10 Switch User Manual
Contents
1. Note If DHCP related functionality DHCP server on the private interface and DHCP client on the public network disrupts your network change the default settings via the console port prior to plugging in the ethernet cables Connect one end of the Cat5e straight through cable to the private port EthernetO on the security gateway Connect the other end to the LAN hub or switch Note A crossover cable is required if the SG203 security gateway is connected directly to a workstation Connect the power cable to the security gateway and then plug it in to an AC outlet Power on the security gateway and proceed to Chapter 3 Setting up the security gateway for configuration The following are the default values for the security gateway DHCP Client public interface is enabled DHCP Server private interface is enabled Private Interface IP address is 192 168 1 1 Administrative user name is root Password is password 22 Installing SG203 and SG208 Security Gateway March 2004 Chapter 3 Setting up the security gateway for configuration This chapter describes how to set up the security gateway addressing and remote connectivity capabilities This preliminary configuration is performed using a browser on your workstation connected to the security gateway s private port When the security gateway is initially installed and connected to the local LAN it is provisioned with a default IP address for the DHCP server
2. Product Safety Standards This product complies with and conforms to the following international Product Safety standards as applicable Safety of Information Technology Equipment IEC 60950 3rd Edition including all relevant national deviations as listed in Compliance with IEC for Electrical Equipment IECEE CB 96A Safety of Information Technology Equipment CAN CSA C22 2 No 60950 00 UL 60950 3rd Edition Safety Requirements for Customer Equipment ACA Technical Standard TS 001 1997 One or more of the following Mexican national standards as applicable NOM 001 SCFI 1993 NOM SCFI 016 1993 NOM 019 SCFI 1998 Electromagnetic Compatibility EMC Standards This product complies with and conforms to the following international EMC standards and all relevant national deviations Limits and Methods of Measurement of Radio Interference of Information Technology Equipment CISPR 22 1997 and EN55022 1998 Information Technology Equipment Immunity Characteristics Limits and Methods of Measurement CISPR 24 1997 and EN55024 1998 including Electrostatic Discharge ESD IEC 61000 4 2 Radiated Immunity IEC 61000 4 3 Electrical Fast Transient IEC 61000 4 4 Lightning Effects IEC 61000 4 5 Conducted Immunity IEC 61000 4 6 Mains Frequency Magnetic Field IEC 61000 4 8 Voltage Dips and Variations IEC 61000 4 11 Powerline Harmonics IEC 61000 3 2 Voltage Fluctuations and Flicker IEC 61000 3 3 Federal Co
3. Interface BRI and CTR4 Primary Rate Interface PRI and subsets thereof in CTR12 and CTR13 as applicable Copies of these Declarations of Conformity DoCs can be obtained by contacting your local sales representative and are available on the following Web site http www avaya com support Japan This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may occur in which case the user may be required to take corrective actions LOWE ARRE S E E A ERARAS VCCI ox CES 7 FAATRARAPRE CH ORES RR CHEATS LE d iesaREIdIEAd0Xd COBSIIEMSRBILMRERT SZBEAGBRENSZILEBHVET China BMSI Chinese Warning Label S45 db A a ik Jt PF MAG WA Jo ZEB E 6 XE BEP RA BF gt wp fe dri RITA HE HEE AOU o RM jk 3e Ob te ui de a HIB o Hardware including technical data is subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to export or import regulations in other countries Customer agrees to comply strictly with all such regulations and acknowledges that it has the responsibility to obtain licenses to export re export or import hardware Environmental Health and Safety A WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to Avaya E
4. mask and default router IP address from the security gateway NOTE Unless you have other DNS servers at your local site it is recommended that the Windows DNS and WINS server lists be empty The DNS server built into the security gateway should normally be the sole DNS server that users see Performing the quick setup Quick Setup collects and preconfigures the essential information required to remotely configure and manage the security gateway Note If the security gateway is to be configured and managed locally see the Security Gateway Configuration Guide for the VPNos to perform a comprehensive device configuration The Quick Setup wizard collects the necessary information to communicate with the remote VPNmanager application through the security gateway s public port The following information is required to complete the quick setup The type of addressing to be used on the security gateway s public port either Static IP Addressing Dynamic Addressing DHCP or PPPoE Typically DSL connections use PPPoE and cable modems use DHCP The default is DHCP A network mask for the above e A default route This is the service provider s router used only if Static IP Address is selected The user name and password if your connection to your ISP is PPPoE 24 Setting up the security gateway for configuration March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide To connect to the security gatew
5. serving the private port allowing access to the device through a Web browser on a workstation The following procedure assumes that the security gateway has been physically installed on the network according to the instructions provided in Chapter 2 Installing SG203 and SG208 Security Gateway The security gateway quick setup consists of two basic steps 1 Establishing connectivity between a workstation or IP device on your local network with the security gateway s private port 2 Setting up the security gateway s public port to reach the Internet Through the Web interface you can assign a static IP address for the public port a password server addresses DHCP settings and a default gateway Once this has been done the security gateway can be completely configured and incorporated into your Virtual private Network either by using the Web interface locally or using Avaya VPNmanager from a central location March 2004 Setting up the security gateway for configuration 23 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Connecting to the private port From the workstation s control panel select your TCP IP network component for your Ethernet controller In the IP Address window select enable the setting to Obtain an IP address automatically Restart your workstation if the operating system asks you to do so As your workstation restarts it automatically obtains its required IP address
6. Repeat bracket installation on the other side 4 Install the device into a standard 19 inch rack using screws that fit the rack not provided 18 Installing SG203 and SG208 Security Gateway March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Overview of front panel Figure 5 Front panel of the security gateway Console 8 Ethernet port Private por Status Indicators Public port Multi interface ports Expansion slot Console port The console port accepts an RS 232 DB 9 connection from an asynchronous ASCII terminal or a PC running terminal emulation software The connection requires a null modem cable which is supplied The communication settings for a device interfacing with the console port are provided in Table 5 Table 5 Terminal settings Parameter Setting Baud 9600 Data Bits 8 Parity None Stop bits 1 Flow control None March 2004 Installing SG203 and SG208 Security Gateway 19 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Multi interface ports Four ports are available on the security gateway public private and two other interface ports that are not designated The public port provides an interface to the public Internet network while the private port provides an interface to the private local network The other two could be used for public backup semi private DMZ or management interface zones The SG203 requ
7. in the United States of America hereby certifies that the equipment described in this document and bearing a TIA TSB 168 label identification number complies with the FCC s Rules and Regulations 47 CFR Part 68 and the Administrative Council on Terminal Attachments ACTA adopted technical criteria Avaya further asserts that Avaya handset equipped terminal equipment described in this document complies with Paragraph 68 316 of the FCC Rules and Regulations defining Hearing Aid Compatibility and is deemed compatible with hearing aids Copies of SDoCs signed by the Responsible Party in the U S can be obtained by contacting your local sales representative and are available on the following Web site http www avaya com support All Avaya media servers and media gateways are compliant with FCC Part 68 but many have been registered with the FCC before the SDoC process was available A list of all Avaya registered products may be found at http www part68 org by conducting a search using Avaya as manufacturer European Union Declarations of Conformity CE Avaya Inc declares that the equipment specified in this document bearing the CE Conformit Europe nne mark conforms to the European Union Radio and Telecommunications Terminal Equipment Directive 1999 5 EC including the Electromagnetic Compatibility Directive 89 336 EEC and Low Voltage Directive 73 23 EEC This equipment has been certified to meet CTR3 Basic Rate
8. working on your company s behalf Whereas a malicious party is anyone including someone who may be otherwise authorized who accesses your telecommunications equipment with either malicious or mischievous intent Such intrusions may be either to through synchronous time multiplexed and or circuit based or asynchronous character message or packet based equipment or interfaces for reasons of Utilization of capabilities special to the accessed equipment Theft such as of intellectual property financial assets or toll facility access Eavesdropping privacy invasions to humans Mischief troubling but apparently innocuous tampering Harm such as harmful tampering data loss or alteration regardless of motive or intent Be aware that there may be a risk of unauthorized intrusions associated with your system and or its networked equipment Also realize that if such an intrusion should occur it could result in a variety of losses to your company including but not limited to human data privacy intellectual property material assets financial resources labor costs and or legal costs Responsibility for Your Company s Telecommunications Security The final responsibility for securing both this system and its networked equipment rests with you Avaya s customer System administrator your telecommunications peers and your managers Base the fulfillment of your responsibility on acquired knowledge and resources fro
9. AVAYA Avaya SG203 and SG208 Security Gateway Hardware Installation Guide 670 100 101 Issue 2 March 2004 Copyright 2004 Avaya Inc All Rights Reserved Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of release However information is subject to change Warranty Avaya Inc provides a limited warranty on this product Refer to your sales agreement to establish the terms of the limited warranty In addition Avaya s standard warranty language as well as information regarding support for this product while under warranty is available through the following website http www avaya com support Preventing Toll Fraud Toll fraud is the unauthorized use of your telecommunications system by an unauthorized party for example a person who is not a corporate employee agent subcontractor or is not working on your company s behalf Be aware that there may be a risk of toll fraud associated with your system and that if toll fraud occurs it can result in substantial additional charges for your telecommunications services Avaya Fraud Intervention If you suspect that you are being victimized by toll fraud and you need technical assistance or support in the United States and Canada call the Technical Service Center s Toll Fraud Intervention Hotline at 1 800 643 2353 Disclaimer Avaya is not responsible for any modifications additions or deletions to
10. allation Guide S safety recommendations 17 security 11 SHA1 11 specifications authentication 11 encryption 11 key management 11 standards electromagnetic compatibility 3 T technical support 7 temperature range 15 tools rackmount 17 triple DES 11 U user authentication 11 WwW world wide web support 7 30 Index March 2004
11. ay 1 From a workstation on the private side of the security gateway open your browser and type into the location field one of the following https sg private https 192 168 1 1 security gateway default address 2 Click Yes to accept the security alert message The security gateway login window appears Figure 7 Security Gateway Login Window G208 Log In User Name Password e Log in using default VPN aya Inc All Rights Reserved 3 Enter the User Name root and the Password password Click Log In when it is highlighted 4 The first time you connect to the security gateway two sequential pop up messages appear over the main screen The first is a password change alert that advises you to change the factory default password Change the default password to a secure password 5 The next alert message indicates that the security gateway has not yet been configured Click OK to launch the Quick Setup wizard March 2004 Setting up the security gateway for configuration 25 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Figure 8 Quick Setup Dialog G208 Quick Setup tatie l Se ee PPPOE Client ee i a E a CNN EIS EE foo fse ife 6 The Quick Setup wizard dialog appears In the IP Configuration area select one of the following IP Config Modes Static Addressing If you are going to use static addressing on the public port click the Sta
12. c and private ports The security gateway s primary function is to perform IPSec and firewall security services to protect enterprise networks and to secure data being sent over shared IP networks The security gateway establishes an Internet Key Exchange IKE protocol session with its IPSec peer to perform an authentication and to negotiate the security associations SAs that are used to secure the session Once the successful 10 Introduction March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide negotiation is completed data can then be encapsulated in IPSec tunneling packets that can only be decrypted by the peer on the other end of the IPSec tunnel Additional features Table 1 Additional features Parameter Specification Encryption DES Triple DES and AES hardware encryption DES uses a 56 bit key Triple DES uses three 56 bit independent keys for an effective key length of 168 bits AES is a symmetric 127 bit block data encryption technique AES can be used in place of DES All weak and semi weak keys are automatically discarded Authentication Keyed MD5 Message Digest RFC 1321 HMAC MD5 and HMAC SHA 1 RFC 2104 Key Management ISAKMP Internet Security Association Key Management Protocol Supports network address translation for firewall support User Authentication CHAP PAP VPNmanager Avaya VPNmanager is an optional Avaya application that
13. curity Gateway Hardware Installation Guide Table 3 Physical specifications Parameter SG203 SG208 Dimensions 17 W x 18 5 D x 1 75 H 17 W x 18 5 D x 1 75 H 46 9cm x 43 1cm x 46 9cm x 43 1cm x 4 4cm 4 4cm Weight 17 pounds 7 7 17 pounds 7 7 Kilograms Kilograms LAN Interface Four 10 100 Base T Ethernet Four 10 100 1000Base T Ethernet Management Interface RS 232 RS 232 Ethernet ports EtnernetO is reserved for the Private port and Ethernet1 is reserved for the Public port Ethernet2 and Ethernet3 are software configurable and can be used for fail over DMZ or other functions Each Ethernet port has status indication LEDs that show whether the link is active 14 Introduction March 2004 Chapter 2 Installing SG203 and SG208 Security Gateway Site requirements This chapter provides instructions for the physical installation of the SG203 and SG208 security gateways including rack mounting placement and connection to the network This section describes the requirements your site must meet for safe installation and operation of the security gateway Ensure that your site is properly prepared before beginning installation Environmental requirements The security gateway devices are intended for use in a normal office environment For more extreme conditions verify that temperature humidity and power conditions meet the following specifications e Temperature ra
14. d be up to 63 bytes Table 2 G203 208 performance specifications SG203 SG208 IKE Sessions 3000 8000 IPSec Sessions 12 000 16 000 Subnets supported 2 1 Firewall TCP UDP 200 000 300 000 Sessions VPNremote users 100 3000 100 8000 Default Max Site to Site Default Max 50 300 100 1000 Protected FW VPN 3000 8000 Devices 12 Introduction March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Plug and Play installation The auto sensing interfaces of the security gateway enables installation into any Ethernet network By default the security gateway functions as a DHCP client on the public interface and as a DHCP server on the private interface Immediately after receiving IP connectivity the network administrator can locate the security gateway via https 192 168 1 1 on the private interface The administrator enters the name as root and the password as password for the user s credentials The quick set up guides the network administrator through the minimal network configuration Hardware components Each of the major components are shown in Figure 2 and Figure 3 Figure 2__ Front panel thernet activity indicator Console RS 232 port Private port Public port Multi interface ports EthernetO Etherneti Ethernet2 amp 3 Expansion slot Figure 3 Back panel Power and On Off switch Expansion slot March 2004 Introduction 13 Avaya SG203 SG208 Se
15. dore E arbe ER ERR qd dqaiacig dnas 19 CONS DOE aou exe dob Y EUR obe e eo ed cde AE Qe Rb eor eq ba 19 I Dursmripe qur rm 20 Connecting the SG203 SG208 security gateway to the network 20 Chapter 3 Setting up the security gateway for configuration 23 L ongeoc ng to Hie DEOLVSIE HO oes end ro EErEE SREI PECES ERSE uh gg dx 24 Performing the quick Setup dio teccneeksane ded eekbeeedsa A e tirk Saiki 24 Index 29 Avaya SG203 SG208 Security Gateway Hardware Installation Guide About this book The Avaya SG203 and SG208 Security Gateways are dedicated hardware based network security devices designed to provide overlay security on an IP data network This guide describes the Avaya SG203 and SG208 Security Gateway and how to install and preconfigure these devices It is recommended that you read the entire installation guide before installing the security gateway Contacting Technical Support Technical support is available to registered users of the Avaya security gateway products Domestic support Toll free phone support 866 462 8292 24x7 e Email vpnsupport avaya com e Web http Awww support avaya com International support e For regional support numbers go to http www avayanetwork com site GSO defaut htm March 2004 About this book 7 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Documentation The security gateway documentation includes both the Hardware In
16. fer to the Security Gateway Configuration Guide for VPNos March 2004 Setting up the security gateway for configuration 27 Avaya SG203 SG208 Security Gateway Hardware Installation Guide 28 Setting up the security gateway for configuration March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Index A admin name 25 AES 11 AES encryption 11 authentication specification 11 B back panel 20 C catbe cables 20 CE marks 4 configuring static addressing DHCP PPPoE 26 connecting the SG203 SG208 to network 20 connecting to private port 24 connections router 21 console port 19 contacting technical support 7 D default settings 22 DES 11 documentation 8 E electrical specifications 16 electromagnetic compatibility standards 3 email support 7 encryption specification 11 environmental requirements 15 equipment provided by Avaya 16 provided by customer 16 H hardware components 13 humidity specification 15 I installation desktop 16 rackmount 16 IPSec standards 11 L log out 27 P password 25 performance 12 performance specification 12 phone support 7 plug and play installation 13 power 15 Q quick setup 24 R rackmount installation procedure 18 recommendations safety 17 required tools 17 requirements environmental 15 router connections 21 RS 232 19 March 2004 Index 29 Avaya SG203 SG208 Security Gateway Hardware Inst
17. ires a crossover cable when connecting to a router and uses a straight through cable when connecting to a hub or switch The SG208 can use any type of cable crossover or straight through when connecting to a hub switch or router NOTE To realize maximum performance when operating at the 1000 Base T rate it is necessary to use CAT5e cables shipped with the device Standard CAT5 cables are not rated for full Gigabit data rates Connecting the SG203 SG208 security gateway to the network The supplied Cat5e cables are used to connect the security gateway to the public network and the private LAN Figure 6 shows a typical network using the SG203 and SG208 security gateway 20 Installing SG203 and SG208 Security Gateway March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Figure6 Example of two security gateway s hardware installations 7 PrivateLAN 7 Private LAN SG203 SG208 LI Crossover Cable Router Router I m i mf DSU CSU DSU CSU 1 Connect one end of the Cat5e cable to the public port Ethernet1 on the security gateway Connect the other end to the router s Ethernet port ethernet connector on the DSL or the cable modem For the SG203 use the crossover cable Figure 6 See Multi interface ports on page 20 about using Cat5e cables March 2004 Installing SG203 and SG208 Security Gateway 21 Avaya SG203 SG208 Security Gateway Hardware Installation Guide
18. lets network managers define configure and manage VPNs from any location Large networks would want to use VPNmanager to do distributed managed firewall rules as well as VPN management across the network Security The SG203 and SG208 security gateway employs cryptographic algorithms and keys powerful enough for the most sensitive business communications to provide data stream privacy It supports DES and Triple DES and AES encryption as well as the ISAKMP key management standard March 2004 Introduction 11 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Performance Data authenticity is assured by using HMAC MD5 or HMAC SHA 1 packet signatures to reject altered or forged packets All security mechanisms employed by the security gateway conform to IPSec standards in order to provide interoperability and broaden the use of VPN technology For maximum network flexibility the SG203 security gateway supports four 10 100BASE T Ethernet interfaces and the SG208 supports four 10 100 1000BASE T Ethernet interfaces When packets are encrypted and authenticated according to IPSec protocol guidelines additional bytes in the form of IPSec headers must be added to packets In many cases the additional packet overhead imposes a performance penalty in return for security The extra bytes tend to lengthen packets and reduce the throughput measured in packets per second The overhead depends on the IPSec policy and coul
19. m a variety of sources including but not limited to Installation documents System administration documents Security documents Hardware software based security tools Shared information between you and your peers Telecommunications security experts To prevent intrusions to your telecommunications equipment you and your peers should carefully program and configure Your Avaya provided telecommunications systems and their interfaces Your Avaya provided software applications as well as their underlying hardware software platforms and interfaces Any other equipment networked to your Avaya products TCP IP Facilities Customers may experience differences in product performance reliability and security depending upon network configurations design and topologies even when the product performs as warranted Standards Compliance Avaya Inc is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Avaya Inc The correction of interference caused by such unauthorized modifications substitution or attachment will be the responsibility of the user Pursuant to Part 15 of the Federal Communications Commission FCC Rules the user is cautioned that changes or modifications not expressly approved by Avaya Inc could void the user s authority to operate this equipment
20. mmunications Commission Statement Part 15 Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Canadian Department of Communications DOC Interference Information This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment DECLARATIONS OF CONFORMITY United States FCC Part 68 Supplier s Declaration of Conformity SDoC Avaya Inc
21. nge 32 to 104 F 0 to 40 C Relative humidity 5 95 non condensing Site power considerations Check the power at your site to ensure that you are receiving clean power free of spikes and noise Install a power conditioner if necessary March 2004 Installing SG203 and SG208 Security Gateway 15 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Table 4 Electrical specifications Voltage 100 240 VAC Input frequency 47 63 Hz AC input current 3 5 Amps Equipment requirements The security gateway devices shipping carton should contain 1 Security Gateway 2 Cat5e cables 1 Power supply 1 Null modem cable for console connection 1 Rack mount kit including two mounting brackets and screws for attaching the brackets to the security gateway Hardware required to mount the unit to the rack must be provided by the customer 1 Quick Start Guide To install and use the security gateway in a typical network the customer must supply the following Physical installation Router DSL cable or ISDN modem providing connectivity to a WAN such as the Internet A workstation on the LAN to communicate with the security gateway installed with a Java enabled JDK1 1 8 or later 128 bit encryption capable browser either Internet Explorer 5 5 or later or Netscape 6 2 or later The security gateway can be placed on a desktop or mounted in a rack It is easy to install and req
22. nvironmental Health and Safety guidelines Documentation For the most current versions of documentation go to the Avaya support Web site http www avaya com support Table of Content About this book 7 Contacune Techical Suppalt 52 oap s dented atiadaateseaeedseedaws F DOoocuWTiental Tb ue d acr e CV a rere ee wv ee ee 8 Chapter 1 Introduction 9 Finobungl US VIS ga Rardoa ip CORE CO IE EO REAR EG De A ER 10 Additional EACS io coe BS AE WR ie LASTED DEARLY Hed CE RPG Cdi 11 WPNNI LO per Sk ee eh EERE od qud vue Shi aes vis vas 11 i a AC TIT UrerE 11 Peona uo qi rea do Robe Rr Ree e do ole ede d doa e e 12 Plug and Play mstallalidUu 25 2 osekzeseRkeaecxseckxcRRX AREE UK EES ENE 13 Hardware compon nS sd eb ope E Eee Ret b eae dabei fare 13 EBS PONS a s E kr p ERE RP RODEO ELIE oe Rd dc E TE T pA TG 14 Chapter 2 Installing SG203 and SG208 Security Gateway 13 Site reM ena aaea E Sad E de 15 Environmental feqnitemenis i oi esr r ERE RUE 15 Site power consideralos cuore ice dore RR ENRE ER pde vU ed ecd 13 Eqi padent regire aee ois ooo sa turpi CORRER OC RU Re CR e 16 Physical InsallallOn s Loa ukszebrk peser bed Fic MER EHE EE Yd 16 Eeqgimed Ils 1a eg dob be Sabi e ar tae bbe Ru RR REPE K V Fe Ed 17 Safety recommends phe eee ke Rd RRR Ta REO UB S ODER Rb I7 Dian C O mTPTTTT 17 PSC 2 4 949 40 9 Ed e XAR Lhd GE RRA deem dd Mdb Baa 18 Gvern or COD DIUI L o iib bg
23. phone line Desktop To install on a desktop allow sufficient depth in the rear for cabling and on the sides for ventilation flow March 2004 Installing SG203 and SG208 Security Gateway 17 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Rackmount The SG203 and SG208 security gateways can be mounted in a standard 19 inch equipment rack The location of the chassis and the layout of your equipment rack or wiring room are extremely important for proper system operation Equipment placed too close together inadequate ventilation and inaccessible panels can cause system malfunctions and shutdowns and can make system maintenance difficult The following information can help you plan an acceptable equipment rack configuration e Enclosed racks must have adequate ventilation Ensure that the rack is not overly congested because each unit generates heat An enclosed rack should have louvered sides and a fan to provide cooling air When mounting a chassis in an open rack ensure that the rack frame does not block the ventilation grates If the chassis is installed on slides check the position of the chassis when it is seated all the way into the rack To attach the device to a standard 19 inch equipment rack 1 From one side of the device remove the four front side screws 2 Using the screws provided with the bracket attach the bracket to the device Figure4 Attaching the Rack Mount Brackets 3
24. stallation Guide and the Security Gateway Configuration Guide for VPNos You can down load these guides from http www support avaya com Navigate to Product Documentation VPN and Security 8 About this book March 2004 Chapter 1 Introduction The Avaya SG203 and SG208 Security Gateways are high performance integrated firewall security zone and IPSec VPN gateway devices They are designed to provide the high capacity scalability and reliability required by your networks for IPSec firewall services in one unit or multiple units for enterprise headquarter locations requiring a rack mountable device The security gateway is easy to configure and can either be managed locally from the Web interface or remotely using Avaya VPNmanager M March 2004 Introduction 9 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Figure1 Typical SG203 SG208 security gateway installation Optional configuring ports e DMZ Public Backup PC Card Expansion 1 future e Semi Private Management Comsste PC Card Expansion 0 future m Ethernet Connector d DSL Cable Modem D To Internet Hub Protected Network Functional overview The SG203 and SG208 security gateways are dedicated hardware based network security devices designed to provide overlay security services on an IP data network The security gateway sits behind an edge router and has auto detecting ethernet interfaces on the publi
25. the original published version of this documentation unless such modifications additions or deletions were performed by Avaya Customer and or End User agree to indemnify and hold harmless Avaya Avaya s agents servants and employees against all claims lawsuits demands and judgements arising out of or in connection with subsequent modifications additions or deletions to this documentation to the extent made by the Customer or End User How to Get Help For additional support telephone numbers go to the Avaya Web site http www avaya com support If you are Within the United States click Escalation Management link Then click the appropriate link for the type of support you need Outside the United States click Escalation Management link Then click International Services link that includes telephone numbers for the International Centers of Excellence Providing Telecommunications Security Telecommunications security of voice data and or video communications is the prevention of any type of intrusion to that is either unauthorized or malicious access to or use of your company s telecommunications equipment by some party Your company s telecommunications equipment includes both this Avaya product and any other voice data video equipment that could be accessed via this Avaya product that is networked equipment An outside party is anyone who is not a corporate employee agent subcontractor or is not
26. tic Addressing radio button and enter your IP address network mask and default route information e DHCP If you plan to use DHCP the public port automatically obtains its address from a DHCP server This method is typical for cable modem connections e PPPoE This method is typically used with DSL connections Click the PPPoE radio button and enter your PPPoE user name and password 7 Depending on the IP config mode selected complete the fields that populate the dialog e For Static enter the IP address mask and route For PPPoE enter the user name and password 26 Setting up the security gateway for configuration March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide 8 In the Centralized Management area if VPNmanager is used enter the superuser name and password 9 Inthe Date amp Time area enter the date time and time zone A 24 hour clock is used For example 13 00 00 is equivalent to 1 00 PM 10 Click Save and then click Log Out from the main page to log of the Web interface NOTE When you use Log out you are prompted to save any unsaved changes before exiting If you close your browser unsaved changes are lost You now have entered enough information to allow the security gateway to be accessed over the Internet The remaining configuration process can be completed remotely using VPNmanager or if the security gateway is managed locally you can continue the configuration Re
27. uires a screwdriver for rack mounted devices 16 Installing SG203 and SG208 Security Gateway March 2004 Avaya SG203 SG208 Security Gateway Hardware Installation Guide Required tools The security gateway chassis can be mounted in a standard 19 inch equipment rack Rack mounting requires a Phillips head screwdriver the device rack mount bracket kit and four screws to match the rack Screws for attaching the mounting brackets to the chassis are not provided Instructions for rack mounting are provided in the section Rackmount on page 18 Safety recommendations When using the SG203 SG208 security gateway devices follow these safety guidelines e Keep the chassis area clear and dust free during and after installation Keepthe ventilation gratings clear of any blockages Do notrest equipment in excess of 10 pounds on top of the chassis e Disconnect all power before mounting or unmounting a unit from an equipment rack Never assume power is disconnected from a circuit always check Circuit Breaker 15A Warning WARNING This product relies on the building s installation for short circuit overcurrent protection Ensure that a fuse or circuit breaker no larger than 120 VAC 15A U S 240 VAC 10A international is used on the phase conductor all current carrying conductors SELV Circuit Warning WARNING The Ethernet 10 100 1 000BASE T ports contain safety extra low voltage SELV circuits Do not connect to a tele
Download Pdf Manuals
Related Search
Related Contents
CON FEREN CE - Fraternités Saint Jean Couples Binary Readout System for a Silicon Tracking Detector at LHC W273 EU2 355-095010 - CONRAD Produktinfo. Mini-projet assembleur Pong 68k User Manual-SRD-480D-PORTUGUESE_Web.indb Cremesso Compact manual Hama Splash Light Zenoah YM 415 DW User's Manual Copyright © All rights reserved.