Home
Ariston Heaters Fan User Manual
Contents
1. e da ie 1 Warning The installer should review the contents of this manual with the owner upon completion of installation and the manual should be left with the owner and placed in a location close to the installation DIMENSIONS FOR P10 5 15 5 General Remarks Caution Caution Caution The manufacturer cannot be responsible for the damages caused by improper installation or by failure to follow instructions in this pamphlet Comply with the installation instructions before completing electric connection The thermostat has been pre set at the factory to about 60 C 140 F To reduce the risk of scald injury keep the thermostat at the warm position letter M Fig 3 4 Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time generally 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the open faucet at this time Installation Instructions Wall Mounting The P 10S and P 15S water heaters can be installed under the sink Fasten the supplied mounting bra
2. ARISTON Point of use water heater Electric Water heaters P10S P155 IMPORTANT SAFETY INSTRUCTIONS Warning When using electrical appliances basic safety precautions to reduce the risk of fire electric shock or injury to persons should be followed including 1 READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER 2 This water heater must be grounded Connect only to properly grounded outlet Use only the 3 prong plug that comes with the water heater Do not use an adapter to bypass the ground connection 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use this water heater only for its intended use as described in this manual 5 Do not use an extension cord set with this water heater If no receptacle is available adjacent to the water heater contact a qualified electrician to have one properly installed 6 As with any appliance close supervision is necessary when used by children 7 Do not operate this water heater if it has a damaged cord or plug if it is not working properly or if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact a service facility for examination repair or adjustment 9 Failure to service the anode rod at least once a year could cause the tank to fail and leak KEEP THESE INSTRUCTIONS AT HAND Technical Data Capacity gallons 21 2 4 Power at 120vac 1350 1350
3. NUMBER 1 Cold water inlet 1 2 NPT marked blue 2 Hot water outlet 1 2 NPT marked red 3 3 4 NPT female tapping for relief valve 4 Temperature amp pressure relief valve 3 4 NPT Make sure that the probe of the T amp P valve is no longer than 4 5 Temperature amp Pressure relief valve discharge line to drain Instructions for use Starting and Before connecting the power fillthe tank and system with water and check for leaks To be testing certain that all the air is out of the water system open the hot water faucets on your fixtures until constant water flows from them otherwise damage to the element may occur To start the heating cycle A first make sure tank is full Otherwise the heating element may be damaged B move red on off switch letter F Fig 3 4 to the ON position to the left C turn the thermostat dial clockwise to the preferred position The red light will come on and remain on until that temperature has been reached at which point the light will go off but will automatically come back on when the water temperature drops below the setting chosen Temperature The temperature is controlled by turning the thermostat dial letter M Fig 3 4 counter setting and clockwise to decrease the temperature and clockwise to increase it freeze Note Setting on very hot is for an approximate temperature 63 C 145 F protection Warning The very hot is a scalding temperature
4. OUND SCREW LOCK WASHER 14 THERMOSTAT 691551 15 POWER CORD BRACKET 16 HANGING BRACKET 570341 17 POWER CORD
5. The lowest setting is that point on the dial where with cold water in the tank the light comes on when dialing from the lowest counter clockwise position This lowest setting is for an approximate temperature of 27 C 80 F WARNING Adjusting the temperature dial above the hot setting will increase the risk of scald injury Households with small children the elderly or invalids may require a temperature setting below hot Turning the heater s thermostat to the lowest setting provides economical and effective freeze protection Maintenance Instructions Note Do not attempt to repair the water heater yourself Call a service person for assistance Always unplug the heater prior to servicing or draining the heater Refer to Fig 3 1 5 for corresponding letter parts PERIODIC MAINTENANCE AND PARTS REPLACEMENT Note For most of these operations the water will have to be drained from the heater For all of these operations the power cord needs to be unplugged and the front cover removed Draining 1 If the heater has been installed with flexible hoses unplug the power cord and turn the the heater upside down over a sink to drain the water out of it OR Heater 2 If the heater has been installed with rigid piping siphon the water out through any lower service valve on the inlet side Keep hot water faucet open while siphoning the water out OR 3 If the heater has been installed with flexible hoses it can also be emptied by
6. cket to the wall Use screws that are suitable for the wall material and the weight of the heater Hang the water heater on the bracket Tug downwards on the heater to ensure that both fingers of the bracket are seated in the mounting slots 3 Connections Caution Closed system thermal expansion Connect the cold water inlet pipe to the inlet nipple marked with a blue ring 1 Fig 4 IMPORTANT You must use dielectric fittings if inlet piping fittings are copper or brass Failure to provide dielectric insulation may result in premature tank or nipple failure and will void warranty Dielectric nipples are recommended over unions and are available from a supply house or CEC To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes but not less than combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relief Valves and Automatic Gas Shut off Devices for Hot Water Supply Systems ANSI 221 22 This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into the opening provided and marked for this purpose in the water heater and orient it or provide tubing so that any discharge f
7. ddress listed below and they will arrange for the handling of the claim 3 Whenever any inquiry or service request is made be sure to include the water heater model number the date of manufacture date of installation Dealer s name and the watts and voltage 4 When returning the water heater or component part s they must be individually tagged and identified with the Returned Goods Authorization issued by CEC and shipped prepaid to CEC at the address below _ Controlled Energy Corp 340 Mad River Park Waitsfield 05673 800 642 3111 COMMON SENSE HEAT amp HOT WATER TECHNOLOGY Fax 802 496 6924 www controlledenergy com Rating Plate 6 FIGURE 4 Hot water outlet 2 Relief 3 Valve Connection Temperature Knob 7 6K88 LISTED Merloni TermoSanitari 45 U 782 5011 10 i Cold water inlet Cover Plate On Off T EAE COMMON SENSE HEAT 8 HOT WATER TECHNOLOGY Controlled Energy Corp 340 Mad River Park Waitsfield VT 05673 800 642 3111 802 496 4436 Fax 802 496 6924 www controlledenergy com ARISTON P10 amp P15 INTERIOR COMPONENTS DIAGRAM ARISTON ANODE ROD P10 P15 574305 HEATING ELEMENT 810847 4 FLANGE GASKET 570016 6 HEATING ELEMENT BRACKET 7 HEATING ELEMENT RETAINING NUT 8 TEMPERATURE DIAL 9 COVER 10 SCREW 11 THERMOSTAT WIRE HARNESS 12 GROUND SCREW 13 GR
8. er tank leaks within two 2 years from the date of original installation of the water heater because of a defect in material or workmanship CEC will furnish to such Owner a new heater of the then prevailing comparable model 2 Any Component Part Other than The Inner Tank If any other component part other than the inner tank proves to be defective in material or workmanship within one 1 year from the date of original installation of the water heater CEC will furnish the Owner with a replace ment of the defective part s 3 Verification of Date of Original Installation When Owner cannot verify or document the original date of installation the warranty period begins on the date of manufacture marked on the tag affixed to the water heater EXCLUSIONS 1 THIS LIMITED WARRANTY SHALL BE THE EXCLU SIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED WHETHER WRITTEN OR ORAL INCLUDING BUT NOT LIMITED TO WAR RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 2 Manufacturer shall not be liable for any incidental consequential special or contingent damages or ex penses arising directly or indirectly from any defect in the water heater or the use of the water heater 3 Manufacturer shall not be liable for any water damage arising directly or indirectly from any defect in the water heater component part s or from its use 4 Manufacturer shall not be
9. liable under this warranty if a The water heater or any of its component parts has been subject to misuse alteration neglect or accident or b The water heater has not been installed in accor dance with the applicable local plumbing and or building code s and or regulation s or c The water heater has not been installed in accor dance with the printed manufacturer s instructions or d The water heater is not continuously supplied with potable water LIMITED 2 YEAR WARRANTY 5 The OWNER and not the Manufacturer or his repre sentative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and or repair of the product or any expense incurred by the owner in order to repair the product SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLU SION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE IMPORTANT OWNER SHALL KEEP THIS CERTIFICATE NOTE A water heater should be installed in such a manner that if it should leak the resulting flow of water will not cause damage to the area in which it is in stalled HOW THE OWNER CAN SECURE SERVICE OR MAKE A CLAIM 1 Owner should contact the dealer who sold the water heater covered by this warranty or 2 Owner should submit the warranty claim directly to CEC at the a
10. nd shut the High Limit system down This occurs when water temperature exceeds 190 F and shuts off Switch power to the heating element The shut off device may also trigger from a power outage or electrical storm To reset NORODND IMPORTANT Disconnect heater from electrical power Remove front cover plate and temperature selector dial Firmly press blue reset button B Fig 3 5 Replace temperature dial and cover plate reconnect power IMPORTANT Check the operation of the thermostat turn temperature dial from high to low if the red light does not go off on low setting disconnect power cord and call a service person to replace thermostat If the system works place dial setting to desired setting Note a lower setting is more economical and reduces the risk of scalding CAUTION Call a technician if the high limit needs to be reset frequently Troubleshooting Water does 1 Make sure the power cord is plugged in not get hot 2 Make sure on off switch is turned on F Fig 3 4 or 8 Fig 4 3 Make sure thermostat dial M Fig 3 4 or 7 Fig 4 has been turned clockwise and red on off switch light has come on 4 If light does not come on check that the blue reset button B Fig 3 5 is pushed in follow steps from previous section 5 If the indicator light works properly but temperature does not get hot at tap test for a On Brown Water 1 Odor in Water 1 Wateristoo 1 hot Leaking 1 2 Light no
11. rom the valve will exit within 6 inches above or at any distance below the structural floor and cannot contact any live electrical part The discharge opening must not be blocked or reduced in size under any circumstances Periodic discharge of the temperature and pressure relief valve or failure of the element gasket may be due to thermal expansion in a closed water supply system The water utility supply meter may contain a check valve backflow preventer or water pressure reducing valve which will create a closed water system During the heating cycle of the water heater the water expands causing pressure inside the water heater to increase The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build up of lime on the relief valve seat To prevent this from happening there are two recommendations 1 Install a diaphragm tvpe expansion tank that is suitable for potable water on the cold water supply line The expansion tank must have a minimum capacity of 1 5 U S gallons for every 50 gallons of stored water 2 Install a 125 PSI pressure relief valve in the cold water supply line Make sure the discharge of this valve is directed to an open drain and protected from freezing Contact the local water supplier or plumbing inspector for information on how to control this situation Do not plug the temperature and pressure relief valve Fig 2 Components Parts REFERENCE
12. ry year or so Galvanic and electrolytic corrosion can destroy a tank if the anode rod is spent Rusty water is usually an indication of a spent anode rod If rusty water is present examine anode rod immediately Rapid degradation of the anode rod less than 1 year may indicate the presence of galvanic corrosion due to stray direct current In this case it may be necessary to add a grounding strap from the Ariston tank to the copper plumbing 1 Unplug the power and drain the heater see previous section 2 Remove the heating element see previous section 3 Replace anode rod 4 Refill tank with water before restoring power 1 Unplug and drain the heater see previous section 2 Remove the heating element see section on Removing the Heating Element 3 Remove and reuse anode rod if not spent Best to replace it 4 Install new element with anode rod attached and rubber gasket making sure the gasket and element are positioned correctly Tighten the retaining nut and make the wire connections 5 Refill tank with water before restoring power 1 Disconnect power supply 2 Disconnect the 2 push pull type wires on thermostat Fig 3 5 3 Loosen the two brass screws at right side of thermostat and pull wires out 4 Unscrew and remove the two phillips screws holding the thermostat down 5 Install new thermostat and re attach wiring and screws Resetting Occasionally the high temperature limit shut off device may trigger a
13. siphoning through the inlet side hose Keep a hot water faucet open while siphoning Removing Unplug the power cord and drain the heater see previous section the heating Remove the front cover plate disconnect terminals X and Y Fig 3 3 element Unscrew the heating element retaining nut letter E Fig 3 3 Remove the element by first tapping it inward and then pull out using a circular motion 5 Descaling the heating Element Scale deposits can affect the heating capability of the element Heavy scale can even cause the element to burn out The element can be descaled either chemically or manually A Soak the element in white vinegar or other descaling solution do not soak the rubber gasket Once descaled rinse well with fresh water to which you should add some baking soda OR B Once the element has dried up use a soft brush non metallic to prevent damag ing the stainless steel sheath on element Brush the dried mineral off Reinstall the element with gasket and make the wire connections C Replace anode rod if considerably shorter then diagram letter N Fig 3 2 Warning make sure the tank has been refilled with water before restoring power REPLACEMENT OF PARTS Changing the anode rod Changing the heating element Changing the thermostat The anode rod letter N Fig 3 2 helps protect the tank against corrosion Depend ing on the water condition the magnesium anode rod may need to be changed eve
14. t 1 2 plumbing crossover shut off cold supply to heater and open hot water tap There should be no water flowing Any continued flow indicates a crossover which will effect the temperature and will need to be corrected If the on off light switch does not come on but water gets hot check for faulty bulb If water is cold turn the temperature dial clockwise to a higher temperature setting If still no light follow previous section on how to reset the high limit switch Brown or rusty water indicates a spent anode rod Replace anode rod Smelly water could be due to an unusual reaction between local water and the heater s anode rod Check anode rod Turn the temperature selector dial M Fig 3 4 counter clockwise to lower temperature If temperature never lowers then replace thermostat Check water fittings and T amp P fitting on top of tank Remove front cover and inspect heating element gasket If gasket is not seated prop erly unplug heater and follow steps to drain heater Then remove heating element to reseat gasket A torn gasket will need to be replaced FIGURE 1 5 ARISTON COVERAGE ARISTON THROUGH ITS U S DISTRIBUTOR CONTROLLED ENERGY CORP hereinafter CEC guarantees this water heater to the Owner hereinafter Owner of the water heater at the original installation location against defects in material and workmanship for the periods specified below WARRANTY PERIOD 1 The Inner Tank If the inn
Download Pdf Manuals
Related Search
Related Contents
TELEVISOR A COLORES MANUAL DE SERVICIO HNML-Laser Diode Module OPERATING INSTRUCTIONS ION Audio Vertical Vinyl SIDE-POWER USER MANUAL - Kramer Electronics Universal Metal Industries ULT2830 User's Manual Frigidaire 740 Series Dishwasher User Manual e - Forms User Manual ( Renew Mission Labour Card ) Magic Vac Dinamika Copyright © All rights reserved.