Home
American Standard 4504 Indoor Furnishings User Manual
Contents
1. GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 must face towards the rear of the SINK Fig B INSTALL BLACK GASKET Install BLACK CONE GASKET 1 onto DRAIN BODY 2 from below Note The flat side of the BLACK CONE GASKET 1 must face down FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY LOCKNUT Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that I FLAT SIDE OF WHITE FOAM GASKET 3 is fully compressed GRAY LOCKNUT and not visible Fig B MUST FACE UP 5 POP UP KNOB E POP UP KNOB 1 must be fully down M968806 REV 1 3 6 ATTACH CABLE CONNECTOR E Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B F CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Fig B Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 8 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY m Connect water supply to FAUCET 1 with 1 2
2. IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 E Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length E Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet COUPLING 2 NUT FLEXIBLE SUPPLIES 3 8 0 D BULL NOSE RISERS 3 8 COMPRESSION COMPRESSION CONNECTION NUT M968806 REV 1 3 9 TEST INSTALLED FITTING With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks mp Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions iW A De N nav Release POP UP KNOB 5 down and check all drain connections and P trap for leaks m Tighten if necessary P TRAP 1 0 SERVICE To change direction of handle rotation proceed as follows Turn VALVE in OFF position If spout drips operate HANDLES 1 several times from OFF to ON position Do not force handles turn only 90 To change direction of handle rotation proceed as follows Turn VALVE to OFF position Loosen HANDLE SCREW 2 and pull HANDLE 1 of
3. Installation Instructions SYMPHONY 4504 Centerset Lavatory Faucet with Speed Connect Drain 4504S Congratulations on purchasing your American Standard faucet with the Speed Connect Drain a feature found only on American Standard faucets Speed Connect Drain e 1 3 of the parts installs in 1 3 of the time e No tools needed e Never needs adjustment e Guaranteed to seal properly the first time every time Certified to comply with ANSI A112 18 1 M968806 REV 1 3 Your new American Standard faucet is designed to work only with the Speed Connect drain Helpful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools lt 7 8 _ ore ini Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL FAUCET MIU ires before beginning Turn off hot and cold water supplies before beginning m Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A E Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B HAND TIGHTEN SINK OR MOUNTING INSTALL POP UP DRAIN REAR OF Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A Drop DRAIN BODY 4 through sink drain hole Make sure WHITE FOAM
4. andard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary Jli to make sure it is fully inserted Fig J y LOOP TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing outward If the Cam Cap does not snap into place then rotate the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H to make sure it is fully inserted Fig J Re install the Cam into the Drain rotating the Cam if necessary J P LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing _ A outward If the Gam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unl
5. ation Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F _ REMOVE M968806 REV 1 3 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American St
6. en any corrosion or debris that may have built up Push Drain Body up into the Sink and remove Note If Drain body rotates while loosening Mounting Nut insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed Recommended tools Channel Locks Adjustable Wrench Phillips Screwdriver WHEN DRAIN IS REMOVED WHEN DRAIN IS REMOVED FROM ABOVE SINK FROM BELOW SINK METAL OR PLASTIC TWO PIECE METAL DRAIN BODY WITH PLASTIC DRAIN BODY DRAIN BODY PLASTIC TAILPIECE WITH PLASTIC TAILPIECE om STOPPE STOPPE METAL STOPPER DRAIN PLASTIC UNTHREAD DRAIN BODY METAL FLANGE SINK Qe METAL OR PLASTIC z PIVOT MOUNTING LMOUNTING DRAIN BODY ROD NUT TT NUT and PUD NUN NUT and MOUNTING NUT GASKET GASKET E li PLASTIC PLASTIC TAILPIECE TAILPIECE P TRAP FINISHED FINISHED WALL WALL RALE M968806 REV 1 3
7. f ADAPTOR 3 Remove ADAPTOR SCREW 4 Pull ADAPTOR 3 off VALVE STEM 5 and turn 90 in a way that flat in ADAPTOR 3 catches a different flat in on VALVE STEM 5 Reinstall ADAPTER SCREW 3 HANDLE 1 and HANDLE SCREW 2 AERATOR 6 may accumulate dirt causing distorted and reduced water flow Remove AERATOR 6 and rinse clean If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 1 1 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M968806 REV 1 3 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the aper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustr
8. ocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968806 REV 1 3 TIPS FOR REMOVING YOUR OLD DRAIN Most existing drains can be removed quickly and easily with only a pair of channel lock pliers or a wrench However there may be situations where it is difficult to remove your old drain or determine how the drain is disassembled Depending upon the existing Drain in your sink it is either removed from above or below the sink The illustrations below show some typical drain installations and how they are disas sembled from the sink The following tips can help with some of the more common challenges in drain removal gm Loosen nuts on P Trap using channel locks Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up Remove P Trap half from Tailpiece Use bucket to catch any residual water in P trap E Unthread Pivot Rod Nut from Drain Body and remove Pull Stopper out from Drain Body For Drains that are removed from below Sink gm Loosen Mounting Nut as far down as it will go Push Drain Body up into Sink and unthread Metal Flange from Drain Body Remove Drain Body from below sink For Drains that are removed from above Sink E Unthread Tailpiece from Drain Body E Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks Suggest spraying nut with spray lubricant to loos
Download Pdf Manuals
Related Search
Related Contents
Juniper Networks MX960 User's Manual Dataram 4GB DDR3-1333 Hama 00118624 DFI CA63-EC Motherboard C使用前に刃欠けがないか確認してください。) 外部密閉系冷却水循環装置ネオクール®サーキュレータ Samsung MW102W-S Bruksanvisning IMC Networks iMediaChassis/6 User's Manual ILX Lightwave -- LDT-5980 取扱説明書 - LABOT Copyright © All rights reserved.
Failed to retrieve file