Home
American Standard 2422LA Hot Tub User Manual
Contents
1. lt _ 143mm 7 178 L 13 3 4 349mm 1 RECOMMENDED FITTING LOCATION IN FLOOR FOR DRAIN 64 X 279mm 2 1 2 X 11 CADET CORNER MODEL 2775L 1 m 229 X 305mm mm 9 12 WM 42 1 2 CUTOUT IN 9 FLOOR FOR N DRAIN 1076mm SN 42 3 8 1524mm 60 70mm REF 88 EN PROVIDE ACCESS TO RECOMMENDE PUMP FOR FITTING SERVICING ON ALL LOCATION C 24 INSTALLATIONS 64 X 330mm A 2 1 2 X 13 422 OUTLINE OF p TILES i CUTOUT d archi 1080 gt 42 1 2 OF DRAIN OUTLET 2159mm 85 5X42 MODEL 2805L ELLISSE MODEL 2711L 1829mm mi 1524mm 72 60 36 1 27 OUTLINE OF CUTOUT 102mm 762mm 9 INTEGRAL 152mm gt 1791 X 1181 4 30 FITTING DECK 70 1 2 X 46 1 2 305mm 12 chor DRAIN C L OF DRAIN PUMP 178mm x 381mm 229mm x 356mm 7 x 15 9 x 14 FLOOR FLOOR CUTOUT PUMP CUTOUT 1067mm 42 19mm 3 4 m NEM RECOMMENDED FITTING LOCATION 64 X 279mm 2 1 2 X 11 GRAB BAR FITTING AREA OPTIONAL DECK FITTING AREA PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS ZOuTLNE OF CUTOUT 1486mm x 1029mm 58 1 2 x 40 1 2 DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS 2124 1 AND 112 19 7 PROVIDE ACCESS TO PUMP FOR SERVICE ON ALL INSTALLATIONS 753737 100 Rev C ROUGHING IN RE
2. B 11 279 mm C 20 508 mm 58 1 2 1485 mm x 30 1 2 774 mm 60 3 16 1528 mm x 30 1 2 774 mm 83mm 3 1 4 690 Ib 313 kg 260 kg sq m 53 Ib sq ft 2771L LA V VA 5 x 36 L 1524mm 60 W 914mm 36 H 546mm 21 1 2 A 20 1 8 511 mm B11 279 mm C20 508 mm 58 1 2 1485 mm x 34 1 2 876 mm 60 3 16 1528 mm x 34 1 2 876 mm 83mm 3 1 4 800 Ib 363 kg 260 kg sq m 53 Ib sq ft 7236L LA V VA 6 x 36 L 1829mm 72 W 914mm 36 H 546mm 21 1 2 A 20 1 8 511 mm B11 279 mm C20 508 mm 70 1 2 1790 mm x 34 1 2 876 mm 72 3 16 1833 x 34 1 2 876 mm 83mm 3 1 4 1031 Ib 467 kg 280 kg sq m 57 Ib sq ft 2425L V 5 x32 IA LHO IA RHO L 1524mm 60 W 813mm 32 H 521mm 20 1 2 A 19 1 8 485 mm B 10 1 2 266 mm C 20 1 4 515 mm N D 60 3 16 1528 mm x 30 1 2 774 mm 73mm 2 7 8 675 Ib 306 kg 262 kg sq m 54 Ib sq ft 2645L LA Oval L 1676mm 66 W 914mm 36 H 502mm 19 3 4 A 15 1 4 387 mm B 8 1 4 209 mm 18 1 4 464 mm 64 1625 mm x 34 863 mm 66 3 16 1681 mm x 34 1 2 876 mm 44mm 1 3 4 580 Ib 263 kg 175 kg sq m 36 Ib pies cuadrados 2901L Savona L 1829mm 72 W 1118mm 44 H 559mm 22 A 16 1 4 413 mm B 6 1
3. ON LIGH 1 FACTORY INSTALLED FOR RESALE The heater is equipped with a preset pressure switch The pump must be HEATER P N 753174 100 QD eens Heater Housing running with water flowing in the whirlpool to allow the heater to turn on Indicator Light This light turns on whenever the heater is operating High Limit Switch The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails If the high limit trips frequently call a service technician To manually reset the circuit in the event that the High Limit switch has been activated simply 1 Turn off the whirlpool pump 2 Drain water from the tub 3 Remove power from heater by unplugging at receptacle or turning off circuit breaker 4 The heater circuit will automatically reset in less than 15 minutes 5 Restore power to the heater 6 Whirlpool bath is now ready to use 5 753782 100 Rev B ELECTRICAL CONNECTIONS Install a separate 120VAC 15AMP dedicated circuit with GFCI Ground Fault Circuit Interrupter protection At initial start up with power ON push the GFCI test button The reset button should pop out Push this button in to reset If the GFCI fails to operate in this manner there is a ground fault or malfunction indicating the possibility of electrical shock Turn off the power and do not use the bath until the source of the pr
4. 2 165 mm 20 508 69 3 4 1772 42 1067 72 3 16 1833 42 1 2 1080 140 5 1 2 936 Ib 421 kg 211 kg sq m 43 Ib sq ft 2908L LA Reminiscence L 1676mm 66 W 914mm 36 H 616mm 24 1 4 A 15 1 8 384 mm 152 18 1 4 464 Template provided AS DESIRED 6 659 Ib 299 kg 191 kg sq m 40 Ib sq ft 2711L Ellisse L 1829mm 72 W 1219mm 48 H 546mm 21 1 2 A 17 3 8 441 mm B 4 102 mm 19 1 2 495 70 1 2 1791 mm x 46 1 2 1181 mm 72 3 16 1833 48 1219 102mm 4 965 Ib 434 kg 195 kg sq m 40 Ib sq ft 2773L Cadet 6 x 36 L 1829 72 W 914mm 36 H 502mm 19 3 4 17 432 12 305 18 1 4 464 70 1 2 1791 34 1 4 870 72 3 16 1833 x 36 914 mm 57mm 2 1 4 751 Ib 341 kg 190 kg sq m 40 Ib sq ft Optional 2774L LA Cadet 6 x 42 L 1829mm 72 W 1067mm 42 H 502mm 19 3 4 A 16 1 4 413 mm B 6 1 2 165 mm C 18 1 4 464 mm 70 1 2 1791 mm x 60 1 2 1537 mm 72 3 16 1833 x42 1067 mm 57mm 2 1 4 821 Ib 372 kg 203 kg sq m 42 Ib sq ft Optional 2775L Cadet Corner L 2159mm 85 W 1524mm 60 H 502mm 19 3 4 A 16 1 2 419 mm B 8 1
5. 2 215 mm 18 1 4 464 mm Template provided 756 Ib 343 kg 115 kg sq m 34 Ib sq ft L 1524mm 60 W 1067mm 42 H 546mm 21 1 2 A 16 1 4 413 mm B 6 1 2 165 mm 19 1 2 495 mm 58 1 2 1486 mm x 40 1 2 1029 mm 60 3 16 1528 mm x42 1067 mm 689 Ib 310 kg 191 kg sq m 39 Ib sq ft Optional TABLE 1 753737 100 Rev C ROUGHING IN REFERENCES 5 x 32 MODEL 24221 LA V VA 6 x 36 MODEL 7236L LA V VA d 182mm 11 1524mm 279mm 3 T I 3 1 4 83mm 7 13 3 4 1 Tt 13 374 I om 3 349 LIBI Sz CUT OUT IN 7 UE EE Om FOR DRAIN FI TT CUT OUT IN FLOOR 7 07m A FOR DRAIN 72 Fy bel f JJ 2 2 J 3 1 4 MES 11
6. 83 279mm 5 x 36 MODEL 27711 LA V V OVAL MODEL 2645L LA V VA 60 Y 66 1524 1676mm _ 279mm 286mm 1 3 4 mac 44 11 4 457mm 36 914mm p 36 CUT OUT IN FLOOR 914mm FOR DRAIN md L 2 3 76mm 5 3 8 137mm 4 4 8 1 4 210 5 x 32 IA LHO MODEL 2425L V LHO shown 5 x 32 IA RHO MODEL 2425L V RHO gt 60 1524mm 10 1 2 LL 7 12 191mm 267mm I L 2 7 8 73mm 6 152mm 4 T Y CUT OUT IN FLOOR T ____ FOR DRAIN 16 406mm i 32 813mm 343mm DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS 2124 1 AND A112 19 7 753737 100 Rev C ROUGHING IN REFERENCES CORNER MODEL 6060L V SAVONA MODEL 2901L 76 3 4 1949mm 72 1829mm 54 1 2 65 3 8 1384mm 1661mm 11 1 2 292mm 8 ds 76mm 203mm 17 54 doin 5 1 2 140 5 5 8 SN Lu
7. Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint AFTERCARE and CLEANING e The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance e Always fill the tub with temperate water Excessively hot water may cause surface damage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove stains cigarette tar deposits or other surface blemishes e Abrasive cle
8. No Food or Alcoholic Beverages Use of your bathtub immediately after meals is not recommended Avoid alcohol consumption before or during bathing Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your physician before using the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the bathtub without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this hydromassage bathtub Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no 8 AWG solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in t
9. Support Instructions ecce ne nnn Page 9 Mounting gs 10 Electrical deiner 11 6060L V Corner EZ Install Page 12 Drain Connection and System Page 13 Care and et SERERE d Page 13 Waranty 14 753737 100 2 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS gt F amp F FE WARNING Risk of personal injury Do not permit children to use this unit without adult supervision WARNING Risk of personal injury Do not operate this unit without the guard over the suction fitting WARNING Risk of electric shock Do not permit electrical appliances hair dryer telephone radio etc within 60 inches 1524mm of this unit WARNING Risk of hyperthermia and possible drowning People using medications and or having adverse medical history should consult a physician before using this product WARNING Risk of personal injury Do not overfill unit before entering Entering tub when filled more than 2 3 can cause overflow and slippery conditions Exercise caution when entering and exiting WARNING
10. from the heater bonding lug to the motor frame bonding lug as shown in Figure 3 The conductor is secured to the lugs using set screws The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the homes electrical panel or approved local bonding point as shown in Figure 3 Fig 2 ssauecrcrouner ELECTRICAL INSTALLATION Fig 3 120 VAC HEATER 4 d America Sandar WHITE PUMP MOTOR HEATER RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP MOTOR FRAME LUG AND FROM PUMP MOTOR LUG TO APPROVED GROUND AS SHOWN SEPARATE 15 AMP GFCI OUTLET for 1 6 H P PUMP SEPARATE 20 AMP GFCI OUTLET for2 1 H P PUMP FIRST COPPER CONDUCTOR SECOND COPPER CONDUCTOR PUMP MOTOR FRAME WITH 4 BONDING LUGS TO GROUND ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 753737 100 Rev C 12 DRAIN CONNECTION AND SYSTEM TEST Using recommended drain assembly connect whirlpool drain to waste line in accordance with the drain assembly instructions Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit
11. harden before applying weight to the rim or bottom of NOTE Tile bead kit not included and the bath Any finish material such as tile or wall board must be self supporting if it must be purchased separately contacts the deck of the bath TYPICAL RECESS INSTALLATION TYPICAL PIER TYPE INSTALLATION AS DESIRED 5 5 MOUNTING LEVELING SURFACE FRONT EDGE SIRINGERS WATERPROOF OF BATH MUST lt gt BE SUPPORTED C BY STUD WALL OR AMERICAN STANDARD ACCESS PANEL MUST BE LOCATED APRON KIT ON THE SAME SIDE AS THE MOTOR ACCESS PANEL MUST BE LOCATED ALLOW OPEN FRAMING ON ON THE SAME SIDE AS THE MOTOR PUMP MOTOR END FOR SERVICE ALLOW OPEN FRAMING ON PUMP MOTOR ACCESS PANELS NOT REQUIRED END FOR SERVICE FOR BATH TUBS ACCESS PANELS NOT REQUIRED UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610mm FOR BATH TUBS IS UNLESS AN ACCESS OF AT LEAST 12 X 24 305 X 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED FOR E amp D DIMENSIONS SEE TABLE 1 ON PAGE 5 FOR G amp F DIMENSIONS SEE TABLE 1 ON PAGE 5 9 753737 100 Rev C TYPICAL FLANGE MOUNTING DETAIL SUGGESTED WHIRLPOOL BATH INSTALLATION METHOD WATERPROOF DRYWALL OR CEMENT BOARD TILE 1x3 25 x 76mm WOOD STRINGER FULL LENGTH WATERPROOF DRYWALL OR CEMENT BOARD SEALANT 4 102mm DRYWALL SCREW 1x3 25 x 76mm WOOD STRINGE
12. of publication AS Inc s the right to o make changes in produc S pai ag vailability at any time withou Te otici AS Americas Inc 2008 1 753782 100 Rev B IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS WARNING Risk of personal injury Do not permit children to use this unit without adult supervision WARNING Risk of personal injury Do not operate this unit without the guard over the suction fitting WARNING Risk of electric shock Do not permit electrical appliances hair dryer telephone radio etc within 60 inches 1524mm of this unit WARNING Risk of hyperthermia and possible drowning People using medications and or having adverse medical history should consult a physician before using this product WARNING Risk of personal injury Do not overfill unit before entering Entering tub when filled more than 2 3 can cause overflow and slippery conditions Exercise caution when entering and exiting WARNING No Food or Alcoholic Beverages Use of your bathtub immediately after meals is not recommended Avoid alcohol consumption before or during bathing Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning PF WARNING Pregnancy If you or think you may be pregnant consult your physician before using the bathtub Never drop or
13. 3737 100 a Bath deck support material Tub support structure per installation instructions provided with the tub WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Permit access for servicing motor as noted 4 All building materials and wiring should be routed away from the pump body and heater if equipped PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS GFCI CIRCUIT REQUIREMENTS The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential Optional heater requires a separate 15 amp maximum GFCI circuit The whirlpool should be installed on a 120 vac 20 amp dedicated GFCI circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit fro
14. 72 018 1599 500 020 1583 470 Lifetime Cadet 6 x 42 Lifetime Cadet Corner 2775 X X X X X X X X X X 9272 018 1599 500 020 1583 470 x gt lt Lifetime 5 x 42 2805 For these components please see your Vendor These models require American Standard Lifetime Drain 1599 205 or 1599 500 753737 100 Rev C X X NOT X AVAILABLE X 9160 2001 X 1599 500 020 1583 470 XXX 1583 470 020 1583 470 XXX X SPECIFICATIONS L SIDE VIEW END VIEW I TD DRAIN OVERFLOW B GENERAL SPECIFICATIONS FOR LIFETIME EVOLUTION WHIRLPOOLS AND BATH TUBS Description 6060L V Corner Dimensions L 1949mm 76 3 4 W 1661mm 65 3 8 H 546mm 21 1 2 Drain Overflow A 18 457 mm B 13 3 4 349 mm Height to Underside of Deck C 19 1 2 495 Cut Out Pier GxF Template provided Rough In Recess ExD Template 751680 100 Tub Edge to Centerline Overflow J 130mm 5 5 8 Weight with Water Floor Loading 824 Ib 374 kg 117 kg sq m 25 Ib sq ft Product Weight Gallon to Overflow Apron Mounting Heater Ready for Field Installation Whirlpool Operating Volume 2422L LA V VA 5 x32 L 1524mm 60 W 813mm 32 H 546mm 21 1 2 A 20 1 8 511 mm
15. American Standard Style That Works Better INSTALLATION GUIDE FOR LIFETIME EVOLUTION WHIRLPOOLS AND BATHTUBS MODEL 2422L LA V VA 5 x 32 MODEL 6060L V CORNER MODEL 2771L LA V VA 5 x 36 MODEL 2645L LA V VA OVAL MODEL 7236L LA V VA 6 x 36 MODEL 2425L V LHO 5 x 32 IA LHO MODEL 2425L V RHO 5 x 32 IA RHO MODEL 2901L SAVONA MODEL 2908L LA REMINISCENCE MODEL 2711L ELLISSE MODEL 2773L CADET 6 x 36 MODEL 2774L LA CADET 6 x 42 MODEL 2775L CADET CORNER MODEL 2805L 5 42 THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping you need to finish the whirlpool installation are your selected fittings and electrical connections To insure maximum performance and pleasure from this product please follow the instructions and cautions FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS AS Americas Inc 2008 All product names listed herein are trademarks of AS Americas Inc unless otherwise noted 1 753737 100 Rev C TABLE CONTENTS Safety a General eea 7 4 4 Specifications NOM Tt 5 Roughing in nce Rant eut Re Page 6 8 Framing and
16. FERENCES REMINISCENCE MODEL 2908L LA CADET 6 x 42 MODEL 2774L LA 1676 330mm 557 PROVIDE ACCESS PUMP FOR SERVICING ON ALL INSTALLATIONS 137 E 1829 mm gt 4 i 305 mm 72 229mm 12 RECOMMENDED FITTING LOCATION 914mm 9 gt 64 X 330mm 2 1 2 x 13 36 19 FOR PIER OR ISLAND p 229 x 305mm aia INSTALLATIONS ONLY 457mm 9 X 12 08 FLOOR FINISHED CUTOUT WALL a 64mm REF 2 1 2 d 1067mm _ 42 152 PROVIDE ACCESS TO en 52 6 scr oF rain OF PUMP FOR SERVICE TOUT ON ALL INSTALLATIONS Y 2 AIR VALVES NCOUTLINE OF Rev 8 JETS FITTING 1791mm x 1029mm Con OF DRAIN LOCATION 1 70 1 2 X 40 1 2 CADET 6 x 36 MODEL 2773L PROVIDE ACCESS TO PUMP FOR SERVICING ON ALL INSTALLATIONS 1829 mm RN 229mm 4 305 mm 72 12 RECOMMENDED FITTING LOCATION 64 X 330mm 2 1 2 x 13 19 mm FOR PIER OR ISLAND QA INSTALLATIONS ONLY FINISHED i S WALL 908 74 35 3 4 CUTOUT IN FLOOR 454mm FOR DRAIN 17 7 8 9 57 2 AIR VALVES NCOUTUNE OF CUTOUT Bs 9 EA ALE FITTING B iex od GIO DRAIN LOCATION 1 DIMENS
17. IONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE OF TOLERANCES ESTABLISHED BY ANSI STANDARDS 2124 1 AND A112 19 7 753737 100 Rev C 8 INSTALLATION AND FRAMING INSTRUCTIONS The variety of installations possible for this whirlpool may require framing procedures other than those shown Locate studs as needed Ensure roughing in dimensions are proper plumb and square Provisions must be made in all installations for an access opening for servicing the pump and controls It is strongly recommended that an additional opening be provided for access to the drain components The apron should not be used as the primary access opening 1 Position the whirlpool into the installation opening and level the deck in both directions shimming the integral support feet IF necessary Mark the final position of the underside of the deck by tracing a line on to the studs see Figure 1 2 Remove the whirlpool and attach a 1 x 4 stringer to the studs with the top of the stringer touching the traced line rim of the bath must not support weight FIGURE 1 3 Install drain components to the whirlpool following the drain installation instructions Before TYPICAL INSTALLATION replacing your whirlpool for final installation be certain that an opening has been provided in the sub floor for the drain See the roughing in drawing and Table 1 for suggested opening size shadowed and location dimensions The drain overflow of the bath extends below the b
18. R FULL LENGTH SECURE THE BATH TO THE STUDS AS SHOWN FOR WOOD OR STEEL STUD CONSTRUCTION UNDER DECK MOUNTING INSTRUCTIONS TYPICAL INSTALLATION CORNER 22 N WHIRLPOOL ACCESS PANEL SEE CUTOUT TEMPLATE PROVIDED ON UNDERSIDE OF BOX LID UNLESS AN ACCESS OPENING OF AT LEAST 12 x 24 305 x 610mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED Please note that care must be taken to protect the surface of the tub during all aspects of the installation Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result Install the tub per the installation instructions provided with the unit Prepare the bath deck support structure per the local codes Note the bath deck must be self supporting Cut bath deck to your specifications Place the bath deck in position and trace the opening on the tub with a soft pencil Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line Replace the bath deck and secure it into place Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal Remove excess sealant per the manufacturer s instructions Finished bath deck surface material must be self supporting and secured per local codes Waterproof Sealant Bathtub 75
19. Z INSTALL WHIRLPOOL HEATER If inspection of this AS American Inc American Standard plumbing product within one year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty applies only to the original purchaser and installation of these products This limited warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damages if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implie
20. ahrenheit If the bathtub is too warm simply adjust by adding cold water See Important Safety Instructions supplied with heater High Limit The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails If the high limit trips frequently call a service technician To manually reset the circuit in the event that the High Limit switch has been activated simply 1 Turn off the whirlpool pump 2 Drain water from the tub 3 Remove power from heater by unplugging at receptacle or turning off circuit breaker 4 The heater circuit will automatically reset in less than 15 minutes 5 Restore power to the heater 6 Whirlpool bath is now ready to use Indicator Light The light turns on when the heater is operating Pressure Switch The heater is equipped with a preset pressure switch This switch will not allow the heater to turn on if the pump is not running with water flowing through the whirlpool piping system For 6060L V Corner Only OPERATION Fig 1 WARNING Prior to operation review the Important Safety Instructions listed at the beginning of this instruction manual totally automatic The heater will help maintain the temperature of the water in 2 2 macam Standard Once the heater is installed and the whirlpool pump is operating the heater is 00 the bath E Z INSTALL heater Pressure Switch HEATER
21. aners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by rubbing with a white automotive type polishing compound and waxing with a liquid wax not wax areas where you walk or stand e Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface e Clean the surrounding surface immediately after using caustic drain cleaners e Burning cigarettes will damage the surface Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details e Do not permit drain cleaner to enter the circulation system CIRCULATION SYSTEM CLEANING PURGING PROCEDURES STEP 1 Once every month purge and clean the circulating system Fill whirlpool with warm water and add two teaspoons of dishwasher detergent and one half cup of house hold bleach STEP 2 Activate whirlpool system in accordance with operating instructions or two minutes STEP 3 Drain and refill whirlpool with cool water and circulate for additional five minutes STEP 4 Drain whirlpool completely 13 753737 100 Rev C AS AMERICA INC AMERICAN STANDARD LIMITED LIFETIME WARRANTY FOR LIFETIME EVOLUTION ACRYLIC WHIRLPOOLS AS America American Standard warrants to the original consumer purchaser that it will at its option repair or replace this whirlpoo
22. anty coverage begins on the date the accessory was originally purchased by the owner 5 Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE Some jurisdictions do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these limitations and exclusions may not apply to you 7 Responsibility for compliance with local code requirements Since local code requirements vary greatly distributors retailers dealers installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For service under this warranty you should contact the following By Mail American Standard Inc By Telephone P O Box 659 1 800 442 1902 West Caldwell N J 07007 Attention Customer Care Center AS AMERICA INC AMERICAN STANDARD ONE YEAR LIMITED WARRANTY FOR E
23. d warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from province to province in which case this warranty does not affect such statutory rights For service under these warranties it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be sent to By Mail American Standard Inc By Telephone P O Box 659 1 800 442 1902 West Caldwell N J 07007 Attention Customer Care Center SERVICE For service or repair contact the number below The model number and serial number for your whirlpool are located on a label near the motor HOTLINE FOR HELP For toll free information and answers to your questions call 1 800 442 1902 weekdays 8 00 a m to 5 00 p m Eastern Time Product names listed herein are trademarks of AS America Inc AS America Inc 2008 753737 100 Rev C 14 Americam Standard Style That Works Better Lifetime Evolution Whirlpool and Baths Operating and User Maintenance Instruction Manual Thank you for choosing American Standard ATTENTION INSTALLER Please deliver this manual to homeowner senegal trademarks of AS Americas Inc ino sk n this ale nthe he sipro oe ae es ormatio ala ae at the time
24. ervice under this warranty you should contact the following 4 By Mail American Standard Inc By Telephone P O Box 659 1 800 442 1902 West Caldwell N J 07007 Attention Customer Care Center 7 753782 100 Rev B
25. h an air actuator on off switch and pump with attached power supply cord OPERATING THE SYSTEM WITHOUT WATER DRY RUNNING WILL CAUSE PUMP DAMAGE AND VOID THE WARRANTY Always fill the whirlpool before operating the pump The air switch is mounted either on the deck or side wall of the tub Fill the Whirlpool Water level must be at least one inch 25mm above the highest jet for proper operation See diagram below Do not fill whirlpool more than 2 3 full prior to the user completely immersing themselves into unit Start Whirlpool Push on center of button Button will depress and whirlpool will start Stop Whirlpool Depress and release button and whirlpool will stop SAFE T HEATER REMOVABLE BLANK AIR TUBING AIR ACTUATOR SWITCH location varies with model WATER LEVEL d OUTLET MUST BE GFCI PROTECTED all heaters require separate GFCI DO 6060L V includes factory installed heater Air Volume Control Adjustments Water turbulence is determined by the amount of air mixed with the water Rotate the air volume control counterclockwise for more turbulence clockwise for less Air Volume Control Adjustments A MORE AIR LESS AIR 3 753782 100 Rev B Adjustable Comfort Jet The water flow action may be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and clockwise for soft NOTE You may balance the air volume con
26. he vicinity as needed to comply with local requirements To reduce the risk of an electric shock connect this connector the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this unit SAVE THESE INSTRUCTIONS 3 753737 100 Rev C General Installation Information Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage Before installation and before enclosing with wallboard tile etc the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others For electrical requirements refer to section titled Whirlpool Electrical Installation Instructions Check for availability of optional American Standard wall tiling bead required for recess installation Protect all finished surfaces of the whirlpool during construction and installation u
27. igh Limit Switch The heater includes an exclusive Intelligent High Limit This safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails If the high limit trips frequently call a service technician To manually reset the circuit in the event that the High Limit switch has been activated simply 1 Turn off the whirlpool pump 2 Drain water from the tub 3 Remove power from heater by unplugging at receptacle or turning off circuit breaker 4 The heater circuit will automatically reset in less than 15 minutes 5 Restore power to the heater 6 Whirlpool bath is now ready to use ELECTRICAL CONNECTIONS Install a separate 120VAC 15AMP dedicated circuit with GFCI Ground Fault Circuit Interrupter protection At initial start up with power ON push the GFCI test button The reset button should pop out Push this button in to reset If the GFCI fails to operate in this manner there is a ground fault or malfunction indicating the possibility of electrical shock Turn off the power and do not use the bath until the source of the problem has been identified and corrected 1 Route two separate branch circuits to the junction box near the whirlpool as shown in Figure 2 Each branch circuit MUST BE GFCI PROTECTED and must use copper conductors only 2 Ensure the heater and pump are properly GROUNDED and BONDED as required Attach the 8 AWG solid copper conductor supplied with the heater
28. insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The unit must be connected only to a supply circuit that is properly protected by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the bathtub without the test button being pushed a ground current is flowing indicating the possibility of an electric shock Do not use this hydromassage bathtub Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no 8 AWG solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity as needed to comply with local requirements To reduce the risk of an electric shock connect this connector the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this unit SAVE THESE INSTRUCTIONS 753782 100 Rev B 2 Operation NOTE Each whirlpool is shipped from the factory wit
29. l Company AS America Inc American Standard Limited Lifetime Warranty for Lifetime Evolution Acrylic Whirlpools AS America Inc American Standard warrants to the original consumer purchaser that it will at its option repair or replace this whirlpool or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof of purchase THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS In no event will American Standard be liable for the cost of repair or replacement of any installation materials including but not limited to tiles marble etc This limited warranty DOES NOT COVER the following 1 Defects or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the owner s manual and use of other than genuine American Standard replacement parts in all cases whether caused by a plumbing contractor service company the owner or any other person 2 Deterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories America
30. l or any of its parts that are found by American Standard in its sole judgment to be defective under normal residential use and maintenance so long as it is owned by the original consumer purchaser This warranty shall only become effective upon receipt by American Standard of a completely filled out Warranty Registration Card evidencing proof of purchase THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS In no event will American Standard be liable for the cost of repair or replacement of any installation materials including but not limited to tiles marble etc This limited warranty DOES NOT COVER the following 1 Defects or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the owner s manual and use of other than genuine American Standard replacement parts in all cases whether caused by a plumbing contractor service company the owner or any other person 2 Deterioration through normal wear and tear and the expense of normal maintenance 3 Commercial application 4 Options and accessories American Standard s limited warranty on these items is one year for parts only and excludes labor This one year limited warranty covers accessories manufactured by American Standard e g aprons drains grab bars heaters trim kits against defects of material or workmanship Warr
31. m the electrical supply panel A grounded neutral wire and a third wire earth ground are essential Optional heater requires a separate 15 amp maximum GFCI circuit 120 VAC WHITE ELECTRICAL DIAGRAM m READ AND FOLLOW ALL INSTRUCTIONS Motor Hi Performance Rating 2 1 H P 1 4 H P and 1 25 H P 115V Power Line 10 8 FOR MODEL NUMBERS 2422 2425 2645 2771 2805 2908 ALL MODELS 7236 2774 MODELS ENDING IN SUFFIX LA LAC VA VAC 6060 2775 2773 2711 2901 ALL MODELS 7236 2774 MODELS ENDING IN SUFFIX L LC V VC The sizes shown on this chart are recommendations for copper conductors only Always follow local and national electrical codes 753737 100 Rev C For 60601 Corner Only OPERATION Fig 1 WARNING Prior to operation review the Important Safety Instructions listed at the beginning of this instruction manual Once the heater is installed and the whirlpool pump is operating the heater is A totally automatic The heater will help maintain the temperature of the water in VMETTCAM fv testa the bath E Z INSTALL weater Pressure Switch HEATER ON LIGHT gt FACTORY INSTALLED NOT FOR RESALE The heater is equipped with a preset pressure switch The pump must be HEATER P N 753174 100 running with water flowing in the whirlpool to allow the heater to turn on cres Indicator Light This light turns on whenever the heater is operating H
32. n Standard s limited warranty on these items is one year for parts only and excludes labor This one year limited warranty covers accessories manufactured by American Standard e g aprons drains grab bars heaters trim kits against defects of material or workmanship Warranty coverage begins on the date the accessory was originally purchased by the owner 5 Postage or shipping costs for returning products for repairs or replacement under this limited warranty and labor or other costs incurred in connection with product removal or installation under this limited warranty 6 ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ALL OF WHICH ARE HEREBY EXPRESSLY DISCLAIMED OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED WARRANTY OF ANY IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY OR FITNESS FOR AN INTENDED PURPOSE Some jurisdictions do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so these limitations and exclusions may not apply to you 7 Responsibility for compliance with local code requirements Since local code requirements vary greatly distributors retailers dealers installation contractors and users of plumbing products should determine whether there are any code restrictions on the installation or use of a specific product This warranty gives you specific legal rights You may have other legal rights that vary from state to state For s
33. oblem has been identified and corrected 1 Route two separate branch circuits to the junction box near the whirlpool as shown in Figure 2 Each branch circuit MUST BE GFCI PROTECTED and must use copper conductors only 2 Ensure the heater and pump are properly GROUNDED and BONDED as required Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3 The conductor is secured to the lugs using set screws The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the homes electrical panel or approved local bonding point as shown in Figure 3 SEPARATE Fig 2 15 AMP GFCI OUTLET 120 VAC Fig 3 ELECTRICAL INSTALLATION HEATER HEATER SEPARATE 15 AMP GFCI OUTLET for 1 6 SEPARATE 20 GFCI OUTLET for2 1 H P PUMP RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP MOTOR FRAME LUG AND FROM PUMP MOTOR LUG TO APPROVED GROUND AS SHOWN FIRST COPPER CONDUCTOR SECOND COPPER CONDUCTOR PUMP MOTOR FRAME WITH BONDING LUGS TO GROUND PUMP MOTOR ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and maintenance Your new acrylic bathtub is tough durable and easy to care for The colo
34. ottom of the bath Note that this requires a cutout in the floor A The floor structure beneath the bath must be able to support a total weight of bath water and bather Refer to Table 1 under total weight for your model For Models 2425L V LHO and 2425L V RHO This bath must be supported along its entire bottom Use mortar as bedding material do not use sand or foam Apply enough mortar to support the complete bottom of the bath After the mortar has been poured and before it sets position whirlpool or bath within recess until the rim is leveled against the leveling stringers see Typical Recess Installation shown below The of the bath must not support weight Allow the mortar material to completely harden before applying weight to the rim or bottom of the bath Any finish material such as tile or wall board must be self supporting if it contacts the deck of the bath For Models 2645L V 2771L V 6060L V 7236L V 2422L V and 2422LA VA Replace whirlpool and re shim the integral support feet shimming the entire length of the support feet Secure the shims using construction adhesive silicone mortar or equivalent materials While not a necessity the use of a foundation base consisting of cement mortar or grout will help provide a solid and secure installation ie ss STRINGER 1x4 notf rt The rim of the bath must not support weight If foundation base is used allow the bedding material to completely
35. reas can be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax Do not wax surfaces where you walk or stand Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface Clean the surrounding surface immediately after using caustic drain cleaners Do not permit drain cleaner to enter circulation system Burning cigarettes will irreparably damage the surface of the whirlpool CLEANING PURGING THE CIRCULATION SYSTEM Once every month the circulating system must be purged and cleaned Follow the steps outlined below 1 Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher not laundry detergent and one half cup of household bleach to filled whirlpool 2 Activate whirlpool system in accordance with operating instructions and run system for two minutes 3 Drain and refill whirlpool with cold water Circulate for five minutes 4 Drain whirlpool completely after step 3 above is completed For Troubleshooting and Repair Parts please log on to www americanstandard us com Lestoil amp is a registered trademark of The Clorox Company Lysol is a registered trademark of The Linden Company Windex is a registered trademark of S C Johnson and Son Inc Mr Clean is a registered trademark of The Proctor and Gamble Company DowQ is a registered trademark of The Dow Chemica
36. rs have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface will retain its lasting luster with proper care and maintenance CLEANING AND MAINTENANCE Always fill the tub with temperate water Excessively hot water greater than 130 may cause surface damage Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage Clean after use with a mild liquid household detergent cleaner Do not turn on jets when such cleaners are present Do not use Lestoil Cleaner Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Cleaner Mr Clean Cleaner Dow Disinfectant Bathroom Cleaner or other cleaning products in aerosol cans No Soap Oils Do not operate the whirlpool circulation system when using soap bath oil or a bubble bath or if such substances are in solution in the bathwater If introduced into the circulation system they are likely to cause excessive foaming Bathe with soap or oil only when whirlpool circulation system is off Drain whirlpool after each use 753782 100 Rev B 6 HARSH CHEMICALS SHARP AND ABRASIVE OBJECTS SHOULD NEVER BE USED ON ACRYLIC SURFACES Do not use wire brushes knives or sharp objects to remove stains or other surface blemishes Use of abrasive cleaners or powders will dull the surface If the glossy surface looses its sheen dulled a
37. sing a drop cloth A WARNING Do not lift whirlpool by the piping harness at any time List of Required Tools and Supplies Tools Level Tape Measure Pipe Wrench Slip Joint Pliers Screw Driver Standard Woodworking Tools Personal Safety Equipment Caulking Gun LIST OF OPTIONAL COMPONENTS NOT INCLUDED Description Lifetime Evolution Corner Model Number Supplies Nails Putty Caulking waterproof e 1x4 Stringers Drop Cloth Cement Plaster Grout Optional Components Required Components Not Included Not Included E Z Install Heater INCLUDED Apron Kit 0707 200 Tile Bead Kit Drain White 1599 500 020 Drain Specify Finish 1583 470 Lifetime V Evolution 5 x 32 X 9261 019 1599 500 020 1599 205 XXX Lifetime V Evolution 5 x 36 9261 019 1599 500 020 1599 205 XXX Lifetime V Evolution 6 x 36 9271 019 1599 500 020 1599 205 XXX Lifetime V Evolution 5 x 32 INTEGRAL 1599 500 020 1599 205 XXX Lifetime Evolution Oval 9266 018 1599 500 020 1583 470 Lifetime Savona AVAILABLE 1599 500 020 1583 470 XXX Lifetime Reminiscence NOT AVAILABLE 1599 500 020 1583 470 XXX Lifetime Ellisse NOT AVAILABLE 1599 500 020 1583 470 XXX Lifetime Cadet 6 x 36 92
38. trol and nozzle adjustment for the most desirable condition Large Jet Small Jet Softer Massage Softer Massage counter clockwise counter clockwise More Vigorous Massage More Vigorous Massage clockwise clockwise Lifetime Drain Model 1599 required on Models 7236L LA V VA 2422L LA V VA 2425L V 2771L LA V VA Overflow Partially fill tub then enter tub before completely filling to prevent overflow Tip Toe Drain Depress drain cap to open or close drain Access Panel Model 2425L V Remove access panel to service motor Tip Toe Drain Overflow Access Panel 753782 100 Rev B 4 Optional In Line EZ Install Heater Operating Instructions Some whirlpools are equipped for use with the optional EZ Install Heater Whirlpool Bath Heater part no 9075 120 Simply locate the EZ Install Heater Removable Blank near the whirlpool pump and replace it with the heater Be sure to FOLLOW ALL OPERATING INSTALLATION and SAFETY INSTRUCTIONS THAT COME WITH YOUR EZ INSTALL HEATER CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION The heater will maintain the temperature of the water in the whirlpool or increase the temperature of the water in the whirlpool at about two to four degrees Fahrenheit per hour up to a maximum of 104 F The heater includes the following components Thermostat The Smart Thermostat requires no adjustment and will automatically maintain the water temperature at 104 F