Home

American Standard 2088 Indoor Furnishings User Manual

image

Contents

1. COUPLING NUT 7 SUPPLY VALVE NUT Pe a COMPRESSION ae gl COLLAR ADJUSTMENTS TRIM PLATE f The flushometer tank is designed and factory adjusted to provide a consistent safe seal depth in the bowl after each flush Field refill adjustment is not required VALVE h The refill has been preset and locked CONNECT WATER SUPPLY FLUSH ACTUATOR ADJUSTMENT The spacing between the bellcrank and Connect water supply line between flush actuator may be adjusted to assure positive operation of the trip lever shutoff valve and tank water inlet fitting Tighten coupling nuts securely Remove tank cover and check that there is approximately 1 32 0 8mm gap between the top of the actuator and bottom of the spring rod when it is lifted to Turn on supply valve and allow remove slack from linkage flushometer tank to fill Proceed as follows If necessary loosen set screw in actuator cap and turn cap to increase gap o clockwise or decrease gap counterclockwise as needed Check for leakage at fittings tighten or correct as needed Tighten setscrew securely after adjustment is completed Replace tank cover REPAIR PARTS LIST NOTE XXX and YYY represent color or trim finish options Specify when ordering ITEM PART NO DESCRIPTION 738473 YYYOA TRIP LEVER LH 738494 YYYOA TRIP LEVER RH 4098 100 XXX TANK COMPLETE WITH COUPLING COMPONENTS AND L H TANK TRIM 4098 800 XXX TANK C
2. Fixture studs should project 2 1 8 from face of finished wall 762mm OR 6 32 813mm 7 1 2 ie cy 4 3 1 4 83mm L 3 4 19mm REF 4 7 8 22mm DIA HOLES Side View American Leal Lhasa Sadana Standard Stamdard Standard Standard edela Saniwares Product names listed herein are trademarks of American Standard Inc American Standard Inc 2006 Front View 730480 100 Rev B USE FUTURE R FO SAVE Place back up nuts on both bottom bolts and the top left hand bolt only Adjust the two lower back up nuts so that front face of nuts is flush with finished wall Adjust waste horn to project 5 16 from finished wall a FINISHED WALL NOTE Bearing nuts and washers must be set to take full loading from the fixture allowing 1 16 clearance between fixture and wall Follow support manufacturer s recommended setting of closet outlet connection Place felt or neoprene gasket wax ring not recommended on closet outlet When the fixture is installed closet outlet gasket must be compressed sufficiently to assure a gas and watertight seal The following steps require a helper Install bowl on support using cap nuts and fiber washers with the back up nuts and washers DO NOT APPLY TOP RIGHT FIBER WASHER AND CAP NUT UNTIL OTHER CAP NU
3. INSTALLATION INSTRUCTIONS GLENWALL 1 6 GPF TWO PIECE PRESSURE ASSISTED WALL MOUNTED TOILETS Model 2093 Elongated Meets the American Disabilities Act Guidelines and ANSI A117 1 Requirements for the Physically Challenged Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure this product is installed properly please read these instructions carefully before you begin Certain installations may require professional help Also be sure your installation conforms to local codes A CAUTION PRODUCT IS FRAGILE TWO PEOPLE ARE RECOMMENDED FOR HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY NOTE For proper operation product requires a minimum of 25 psi working line pressure RECOMMENDED TOOLS FINISHED WALL AND MATERIALS Closet Carrier Support Putty Knife Regular Screwdriver Adjustable Wrench Sealant Tape Measure Flexible Supply Tube Carpenters Level Refer to instructions supplied with 3 1 4 wall carrier for proper installation 89mm of 4 bolt support system wall A f A 5 1 4 6 16 1 2 cavity requirements and rough in 433mm 419mm information for waste outlet piping 7 3 7 8 gi a SUPPLY AS emm en REQUIRED 1 2_ 368mm OR amp 16 1 8 When installed top of seat is Gen Ea 156mm 17 to 19 432mm to 483mm C L OF WASTE from the finished floor OUTLET FINISHED WALL FIXTURE MOUNTING 2 1 8
4. OMPLETE WITH COUPLING COMPONENTS AND R H TANK TRIM 735083 400 XXX TANK COVER 3402 016 XXX BOWL 738493 0070A SPRING ROD ASSEMBLY LH 738495 0070A SPRING ROD ASSEMBLY RH 730599 0070A COUPLING GASKET 738496 0070A LOWER SUPPLY ASSEMBLY 35 PSI 047562 0070A UPPER SUPPLY ASSEMBLY 047563 0070A VALVE CARTRIDGE ASSEMBLY 730292 0070A TANK COUPLING KIT 735083 600 XXX TANK COVER FOR LOCKING DEVICE 603111 0030A COVER LOCKING DEVICE KIT CARE AND CLEANING When cleaning your toilet wash it with mild soapy water rinse thoroughly with clear water and dry with a soft cloth Avoid detergents disinfectants or cleaning products in aerosol cans NEVER use abrasive scouring powders or abrasive pads on your toilet seat Some bathroom chemicals and cosmetics may damage the seat s finish 730480 100 Rev B TROUBLESHOOTING GUIDE NOTE The presence of a small amount of water in the bottom of the tank is normal The air inducer is designed to leak for short periods during each flush cycle as a self cleaning action Drippage is drained into the bowl If used on water system containing excessive sand and or debris a periodic cleanup of inlet strainer is recommended See enclosed WARNING instructions for strainer cleaning When servicing or replacing components of the flushometer tank system be sure that the water supply is shut off and the toilet is flushed to relieve pressure in the flushome
5. TS HAVE BEEN FIRMLY TIGHTENED USING A WRENCH Install top right cap nut with fiber washer and run up hand tight Wrench tighten approximately 1 4 turn Apply sealant to gap between bowl and finished wall Remove excess sealant 730480 100 Rev B Using a level adjust the top left back up nut so that it is in the same vertical plane as the lower left back up nut If wall surface is irregular the three back up nuts must be positioned to allow a minimum 1 16 gap between fixture and wall surface 1 16 IRREGULAR WALL SURFACE FINISHED WALL E OoTh 0 ad LEVEL U SPONGE WASHER INSTALL TANK AND TOILET SEAT Install large rubber gasket over threaded outlet on bottom of tank with tapered side out and lower tank onto bowl so that the tapered end of gasket fits evenly into bowl water inlet opening and tank mounting bolts go through mounting holes Secure with metal washers and nuts With tank parallel to wall alternately tighten nuts until tank is snugged down evenly against sanitary bar on bowl A CAUTION DO NOT OVERTIGHTEN NUTS MORE THAN REQUIRED FOR A SNUG FIT Install toilet seat according to manufacturer s directions TANK WATER INLET A WASHER gt e FLEXIBLE
6. an Standard plumbing product within one year after its initial installation confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse accident or other damage if it was not installed in accordance with American Standard s instructions or if it has been modified in a manner inconsistent with the product as shipped by American Standard American Standard s option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation nor shall American Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this warranty Some states or provinces do not allow the exclusion or limitation of implied warranties so this exclusion may not apply to you This warranty gives you specific legal rights You may have other statutory rights that vary from state to state or from
7. province to province in which case this warranty does not affect such statutory rights For service under this warranty it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased or that a service request including a description of the product model and of the defect be sent to the following address In the United States In Canada In Mexico American Standard Inc American Standard Customer Service Manager P O Box 6820 2480 Stanfield Road Ideal Standard S A de C V Piscataway New Jersey 08855 Mississauga Ontario Via Morelos 330 Attention Director of Consumer Affairs Canada L4Y 1S2 Col Santa Clara For residents of the United States Toll Free 800 387 0369 Ecatepec 55540 Edo Mexico warranty information may also be www americanstandard ca www americanstandard com mx obtained by calling the following toll free number 800 442 1902 www americanstandard us com 730480 100 Rev B 4
8. ter tank For service of the Flushometer Tank System see enclosed literature PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Does not flush Water supply valve closed Open valve and allow water to fill tank Flush actuator incorrectly set Follow instruction to adjust flush actuator Supply line blocked Shut off water supply disconnect supply line and inspect all gaskets and washers Reassemble Trip lever linkage damaged Check trip lever linkage and spring rod assemblies for damage Poor or sluggish Supply valve partly closed Open supply valve fully Be sure that proper supply tube flush size is used Plugged inlet strainer Remove and clean strainer per enclosed instructions Supply pressure too low Normal supply pressure must be at least 25 psi Partially clogged trapway and or Remove obstruction Consult a plumber if necessary drain pipe and or vent Malfunctioning pressure regulator Replace lower supply assembly Toilet leaks Poor supply line connection Review Step 7 of installation procedure Poor bowl to wall waste outlet Review Step 3 through 5 of installation procedure connection Tank bowl connection Check tank for movement Refer to Step 6 Toilet does not Supply pressure too low Normal supply pressure must be at least 25 psi shut off Flush actuator incorrectly set Follow instructions to adjust flush actuator AMERICAN STANDARD ONE YEAR LIMITED WARRANTY If inspection of this Americ

Download Pdf Manuals

image

Related Search

Related Contents

  Dell PowerVault DL2000 User's Manual  36613_Nass-und Trockensauger_Cover_LB3.indd  HQ Sweet Sixteen Service Manual.indd  Jarden HLH4422EE-WM space heater  LES ARTS ET LE DROIT D`AUTEUR  BULLETINFO n°18 - Chambre d`agriculture du Nord-Pas-de  Philips Cleaning kit SVC2235  StarTech.com DVI-I Coupler / Gender Changer - F/F  Kidde 1798 User's Manual  