Home
Craftsman 580.325600 Owner`s manual
Contents
1. 0 004 0 006 in 0 10 0 15 mm Exhaust 0 004 0 006 in 0 10 0 15 mm Fuel Capacity 5 U S gallons Oil Capacity 28 Ounces 8 Liters Oil Type Above 40 F Sae 30 Below 40 F SAE 5W 30 or 10W 30 12 OWNER S RESPONSIBILITIES Follow the hourly or calendar intervals whichever occurs first More frequent service is recuired when operating in adverse conditions noted below MAINTENANCE SCHEDULE FILL IN DATES AS YOU SERVICE DATES COMPLETE REGULAR SERVICE Before Every 25 HOURS Every 50 HouRS Every 100 MAINTENANCE TASK Each Use or Yearly or Yearly Hours or Yearly SERVICE DATES Check oil level Clean debris Change engine oil Service air cleaner Service spark plug Service spark arrester Clean cooling system Prepare for storage X X X 2 X _ X X X2 If unit is to remain idle for longer than 30 days Change oil after the fiRSt 5 operating hours and every 50 hours or every year whichever occurs first thereafter Change sooner when operating under dirty or dusty conditions 2 Clean or replace more often under dirty or dusty conditions GENERAL RECOMMENDATIONS Regular maintenance will improve the performance and extend the life of the generator See any authorized Sears dealer for service The generator s warr
2. 35 ENSAMBLAJE 36 37 FUNClONAMIENTO 38 41 ESPECIFICACIONES DEL PRODUCTO 42 MANTENIMIENTO 43 45 ALMACENAMIENTO 46 DIAGNOSTICOS DE AVER AS 47 GARANTiA DE EMISIONES 46 49 NOTAS 50 51 PARTES SERVICIO ULT MA PAGINA GARANTIA LIMITADA GENERADORES CRAFTSMAN SEARS le garantiza al comprador original que el alternador y el motor de su generador portatil estara libre de defectos en materiales y mano de obra en los componentes y por el perlodo de tiempo establecido a continuaci6n a partir de la fecha de compra original Esta garantia no es transferible CLIENTE COMERCIAL Alternador 2 Afios segundo afio despide s61o 1 Afio Motor 2 Afios segundo afio despide s61o 1 Afio NOTA Para propbsitos de esta garantia el tdrmino gso del Cliente representa el uso domdstico residencial y de emergencia pot parte del comprador original sin incluir aplicaciones donde la unidad sea usada como fuente de potencia principal El termino Uso Comercial representa todos los otros usos incluyendo alquiler construccibn comercial y para prop6sitos lucrativos Una vez el generador haya tenido uso comercial _ste ser amp considerado como un generador para
3. BACK PAGE LIMITED WARRANTY FOR DELUXE PORTABLE GENERATORS SEARS warrants to the original purchaser that the alternator and engine for its portable generator will be free from defects in materials or workmanship for the items and period set forth below from the date of original purchase This warranty is not transferable and applies only to portable generators driven by the Sears warranted engine CONSUMER COMMERCIAL Alternator 2 years 2nd year parts only 1 year Engine 2 years 2nd year parts only 1 year NOTE For the purpose of this warranty Consumer Use means personal residential household and emergency use by original purchaser not to be used as a primary source of power Commercial Use means all other uses including rental construction commercial and income producing purposes Once a generator has experienced commercial use it shall thereafter be considered a commercial use generator for the purpose of this warranty During said warranty period SEARS will at its option repair or replace any part which upon examination by SEARS is found to be defective under normal use and service Starting batteries are not warranted by SEARS All transportation costs under warranty including return to the factory if necessary are to be borne by the purchaser and prepaid by him This warranty does not cover normal maintenance and service and does not apply to a generator set alte
4. CAUTION Alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer Drain the fuel tank start the engine and let it run until the fuel lines and carburetor are empty Use fresh fuel next season See Storage on page 16 for additional information NEVER use engine or carburetor cleaner products in the fuel tank as permanent damage may occur HOW TO USE YOUR GENERATOR If you have any problems operating your generator please call the generator helpline at 1 800 222 3136 System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles The system ground is connected to the AC neutral wire the neutral is bonded to the generator frame Special Requirements There may be Federal or State Occupational Safety and Health Administration OSHA regulations local codes or ordinances that apply to the intended use of the generator Please consult a qualified electrician electrical inspector or the local agency having jurisdiction In some areas generators are required to be registered with local utility companies If the generator is used at a construction site there may b
5. 49 50 51 Your Home For repair in your home of all major brand appliances iiiiiiiiiiiiiii i i iii ii iiiiiiiiiii i iiii ili ii iiiiiiiiiiii_iX _iiii _i i iiiiiiiiiiiiiiiiiiiiiiil iiiiiiiiii i ii iiii il no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 8004694663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repairof r in items ikevacuums awnequipment iiii and electronics call or go on line for the location of your nearest Sears Parts amp Repair Center 1 800 488 1222 Call an time day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacibn a domicilio y para ordenar piezas 1 888 SU HOGAR sM 1 888 784 6427 Au Canada pour service en franP ais 1 800 LE FOYER Mc 1 800 533 6937 www sears ca e lrs Registered Trademark I TM Trademark I SM Service Mark of Seam Roebuck and Co Mama Regis b ada TMMama de F_biica I SM Marca de Servicio de Sears Roebuck and Co MC MD Marque de commerce I Marque d_pos_e de Seam
6. 5 Grasp the recoil handle and pull slowly until slight resistance is felt Then pull rapidly to start engine WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on IMPORTANT If engine floods place choke ever in Run position and crank until engine starts 6 Move choke lever to Run position a short distance at a time over several seconds in warm weather or minutes in cold weather Let engine run smoothly before each change Operate with choke in Run position NOTE If engine starts after 3 pulls but fails to run or if unit shuts down during operation make sure unit is on a level surface and check for proper oil level in crankcase This unit may be equipped with a low oil 3rotection device WARNING DO NOT touch hot surfaces Allow equipment to cool before touching The generator must be at least 5 feet from structures having combustible walls and or other combustible materials Keep at least 3 feet of clearance on all sides of generator for adequate cooling maintenance and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective workin
7. Owner s manual Engine oil 120 240 Volt 30 Amp locking plug Wheel Kit ASSEMBLING THE WHEEL KIT The wheel kit is designed to greatly improve the portability of your generator NOTE Wheel kit is not intended for over the road use You will need a socket wrench with 1 2 or 13ram sockets and a needle nose plier to install this kit Refer to illustration shown below and install the wheel kit as follows 1 Place the bottom of the generator cradle on a flat even surface Temporarily place unit on blocks to ease assembly 2 Slide axle through both axle mounting brackets on cradle frame as shown 3 Slide a wheel over the axle NOTE Be sure to install both wheels with the air pressure valve on the outboard side 4 Place the e ring onto the groove in the axle You may add the flat washer if desired 5 Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e ring Seat the e ring by pressing the pliers closed 6 Repeat step 3 through 5 to secure second wheel 7 Remove the temporary blocks 8 To aid support leg assembly rest generator on cradle engine end down Attach the support leg with two M8 x 16mm cap screws and two locking hex nuts as shown 9 Use two 13 mm wrenches to tighten leg hardware Rest generator on wheels and support leg 10 Center the handle bracket on generator frame at support leg end of cradle as
8. Salida Total Requerida del Generador 4875 Control de la Energia Para prolongar la vida de su generador y los aparatos que esten conectados al mismo es muy importante cuidarlo cuando se le afiaden cargas electricas Nada deberia estar conectado a los tomacordentes del generador antes de que su motor sea encendido La forma correcta y mas segura para controlar la energia del generador es la de afiadir en secuencias las cargas como se describe a continuaci6n 1 Sin tener nada conectado al generador encienda el motor de la manera descrita en este manual 2 Conecte y encienda la primera carga preferiblemente la mayor que usted tenga 3 Permita que la salida del generador se estabilice el motor funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la proxima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para carla carga adicional que usted tenga NUNCA afiada mas cargas sobre la capacidad del generador Tome una atencion especial en considerar las cargas de corriente segQn la capacidad del generador como se describe arriba Herramienta o Aparato EI6ctrico Esenciales Bombilla _75 vatios Congelador industrial Bomba de aguas negras Refrigerador congelador 18 pies ct_bicos Bomba de agua _ 1 3 HP Calefacci6n enfriamiento Aire Acond de ventana 10 000 BTU Ventilador de ve
9. 2 Retire los cuatro tornillos que sostienen la pantalla apagachispas 3 Inspeccione la pantalla y reempl amp cela si est amp rota perforada o daftada NO use pantallas defectuosas Si la pantaila no esta daSada limpiela con un disolvente comercial 4 Vuelva a instalar la pantalla y a proteccidn del silenciador Sistema de Refrigeracibn de Aire Con el tiempo se pueden acumular residues en las aletas de refdgeraci6n del cilindro y pasar inadvertidos mientras no se desmonte parcialmente el motor Recomendamos que encargue la limpieza del sistema de refrigeracion a un distdbuidor autorizado de servicio Sears siguiendo los intervalos recomendados consulte la secci6n Plan de mantenimiento en la pagina 43 Es igualmente importante que no se acumulen residues en el motor Consulte la seccion Limpieza del generador CLEAN 45 GENERALIDADES El generador debera ser encendido al menos una vez cada siete dfas y debera dejarlo funcionar al menos durante 30 minutos Si no puede hacer esto y debe almacenar la unidad por mas de 30 dfas siga las siguientes instrucciones para preparar su unidad para almacenamiento Almacenamiento Para Periodos Prolongados Es importante evitar que se formen dep_ sitos de goma en las partes esenciales del sistema de combustible como el carburador filtro de combustible manguera o tanque de combustible durante el almacenamiento Tambien la experiencia i
10. maintenance and servicing in the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order You can order a spark arrester through your authorized Sears service dealer WARNING WHEN ADJUSTING OR MAKING REPAIRS TO YOUR ENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed CAUTION DO NOT tamper with governed speed Generator supplies correct rated frequency and voltage when running at governed speed DO NOT modify generator in any way CAUTION See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator CAUTION Use generator only for intended uses If you have questions about intended use ask dealer or contact Sears Operate generator only on level surfaces DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling sl
11. 1800 1806 1800 2006 2000 2506 2500 Check tool or 11 ENGINE TECHNICAL INFORMATION This is a single cylinder overhead valve OHV air cooled engine It is a low emissions engine In the State of California Model Series 200000 engines are certified by the California Air Resources Board to meet emissions standards for 250 hours Such certification does not grant the purchaser owner or operator of this engine any additional warranties with respect to the performance or operational life of this engine The engine is warranted solely according to the product and emmisions warranties stated elsewhere in this manual Power Ratings The power ratings for an individual engine model are initially developed by starting with SAE Society of Automotive Engineers code J1940 Small Engine Power amp Torque Rating Procedure Revision 2002 05 Given both the wide array of products on which our engines are placed and the variety of environmental issues applicable to operating the equipement it may be that the engine you have purchased will not develop the rated horsepower when used in a peice of power equipment actual on site power This difference is due to a variety of factors including but not limited to the following differences in altitude temperature barometric pressure humidity fuel engine lubrication maximum governed engine speed individual engine to engine variability design
12. Roebuck and Co Sears Roebuck and Co
13. are connected Cause 1 One of the circuit breakers is open 2 Poor connection or defective cord set 3 Connected device is bad 4 1 2 3 4 1 2 Fault in generator Short circuit in a connected load Generator is overloaded Engine speed is too slow Shorted generator circuit Fuel valve in the Off position Rocker Switch set to Off Correction 1 Reset circuit breaker 2 Check and repair 3 Connect another device that is in good condition 4 Contact Sears service facility 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact Sears service facility 4 Contact Sears service facility 1 Set fuel valve to the On position 2 Set switch to On 3 Dirty air cleaner 4 Out of gasoline 5 Stale gasoline 3 Clean or replace air 4 Fill fuel tank 5 Drain fuel tank fill with fresh fuel Engine will not start or starts and runs rough 6 7 8 9 Spark plug wire not connected to spark plug Bad spark plug Water in gasoline Overchoking 10 Low oil level 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression Out of gasoline 6 Connect wire to spark plug 7 Replace spark plug 8 Drain fuel tank fill with fresh fuel 9 Open choke fully and crank engine 10 Fil
14. con la valvula para apagar el combustible apagada posicidn OFF Desconecte el cable de la bujia UANDO ALMACENE O GUARDE EL EQUlPO CON COMBUSTIBLE EN EL TANQUE AImacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodomesticos que posean pilotos u otras fuentes de ignici6n porque ellos pueden encender los vapores de la combustible ADVERTENCIA NO toque las superficies calientes Permita que el equipo se enfrie antes de tocarlo El generador debe estar situado a un minimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un minimo de 92 cm 3 pies alrededor de la carcasa del generador para facilitar la ventilaci6n y el mantenimiento del generador En el estado de California es obligatorio segun la ley el uso de apagachispas Secci6n 4442 del Cd_ ligo de Recursos P_blicos de California Otros estados pueden tener leyes similares Las Ieyes federales se aplican en tierras federales Si equipa el silenciador con un apagachispas este debera ser mantenido en buenas condiciones de trabajo Usted puede ordenar el apagachispas a traves de su distribuidor de servicio autorizado Sears ADVERTENCIA CUANDO AJUSTE O HAGA REPARACIONES A SU ENE_DOR Siempre desconecte el alambre de Ia bujia y col6quelo donde no pueda entrar en contacto con la bujia CUANDO PRUEBE LA BUJiA DEL M
15. runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Tool or Appliance Essentials Light Bulb 75 watt Deep Freezer Sump Pump Refrigerator Freezer 18 Cu Ft Water Well Pump 1 3 HP Heating Cooling Window AC 1O_OOOBTU Window Fan Furnace Fan Blower 1 2 HP Kitchen Microwave Oven 1006 Watt Coffee Maker Electric Stove Single Element Hot Plate Family Room DVD CD Player VCR Stereo Receiver Color Television 2T Personal Computer w 17 monitor Other Security System AM FM Clock Radio Garage Door Opener 1 2 HP Electric Water Heater 40 Gallon DIY Job Site Quartz Halogen Work Light Airless Sprayer 1 3 HP Reciprocating Saw Electric Drill 1 2 HP Circular Saw 7 1 4 Miter Saw 10 Table Planer 6 Table Saw Radial Arm Saw 10 Air Compressor 1 1 2 HP Wattages listed are approximate only appliance for actual wattage Additional Rated Running Surge Watts Starting Watts 75 500 500 860 1200 860 1600 1006 2000 1206 1800 300 600 860 1300 1006 1506 1506 2506 100 100 45O 5OO 8OO 180 3OO 480 526 4006 1006 660 1200 960 966 1006 1000 1506 1500 1806
16. see page 22 NUT Palnut 3 16 ENGINE Parts Not Illustrated 191646GS 43438GS AB3061GS 191559GS DECAL Set PLUG 250V 30A BOTTLE Oil MANUAL Owners Optional Accessories Not Shown 0932688GS Cord Wrap Kit 9932785GS Storage Cover Items without part numbers are common fasteners available at local hardware stores 21 CRAFTSMAN 5600 Watt AC Generator 580 325600 Control Panel Exploded View and Parts List m 7 6 2 13 12 9 s 10 16 15 11 17 14 Item Part 1 195112GS 2 188889GS 6 68759GS 7 8 84198GS 9 75207GS 10 43437GS 11 12 13 93857GS 14 188890GS 15 16 22694GS 17 Description KIT Control Panel Lid CONTROL PANEL Compact OUTLET 120V 20A Duplex NUT Palnut Pushnut 5 32 CAP Circuit Breaker BREAKER Circuit OUTLET 120 240V Locking 30A NUT Palnut Pushnut 3 16 SCREW Phillips Head 3 5 x 18 BAR Retaining COVER Back Control Panel SCREW Self Tapping STC 3 x 18 HOUSING Receptacle SCREW Phillips 3 5 x 14 Items without part numbers are common fasteners available at local hardware stores 22 CRAFTSMAN 5600 Watt AC Generator 580 325600 Wheel Kit Exploded View and Parts List l 3 7 8 Item Part Description 1 189715GS ASSY Handle 2 B1764GS LEG Mounting 3 52858GS NUT Locking Hex M8 1 25 4 HHCS M8 1 25 x
17. will not apply to service at any other facility At the time of requesting warranty service evidence of original purchase date must be presented SEARS ROEBUCK AND CO Dept D 817 WA Hoffman Estates IL 60179 U S A Sears Roebuck and Co _IL This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death _Read this manual carefully and become familiar with your generator Know its applications its limitations and any hazards involved The safety alert symbol A is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a hazard which if not avoided could result in death or serious injury CAUTION indicates a hazard which if not avoided might result in minor or moderate injury CAUTION when used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death WARNING The engine exhaust from this product contains chemicals known to the State of California to cause cancer b rth defects or other reproductive harm WARNING This generator does not meet U S Coast Guard Regulation 33CFR 183 and s
18. 45 5 191267HGS AXLE 5 8 x22 87 6 B4966GS WHEEL 7 191265GS E RING 8 WASHER Flat 5 8 9 HHCS M8 1 25 x 16 Parts Not Illustrated 189718GS GRIP 189716GS CAP Handle End Items without part numbers are common fasteners available at local hardware stores 23 CRAFTSMAN 5600 Watt AC Generator 580 325600 Alternator Exploded View and Parts List 5 6 2 1 8 10 13 Item Part 1 186059GS 2 190032GS 3 190079AGS 4 186060GS 5 86308HGS 6 91825GS 7 66849GS 8 22694GS 9 81917GS 10 193428AGS 13 194274GS Description ADAPTER Mounting Alternator ROTOR STATOR RBC with O Ring p n 189197GS HHCS M6 1 0 x 140 SEMS ASSY Holder RectifiedBrush TAPTITE M5 0 8 x 16 RECEPTACLE 6 pin PIN Roll 4ram x 10 ASSY Wire Ground HARNESS Wire Power 24 ENGINE 10 HP Briggs and Stratton 204412 Exploded View 718A 12 718 j 742 1052_ 774_ 493 356 799A_ 105_ 22 _ 364 306 15 307 28_ cJ 615 27 o 7 883 1095 VALVE GASKET SET 868 358 ENGINE GASKET SET _o_ _ gt 8_ 51A_ 3o_ 25 ENGINE 10 HP Briggs and Stratton 204412 Exploded View 868 798_ 11oo 121 CARBURETOR OVERHAUL KIT 633 105 633 51A_ 914 95 633 231 117 369 _ 127 O 105_ 137 950 26 ENGINE 10 HP Briggs and Stratton 204412 Exploded View 347 188_ 564A 334 564 977
19. cumpla las especificaciones ILSAC GF 2 con marca de certificacion API y con simbolo de servicio API con SJ CF ENERGY CONSERVING o superior es un aceite aceptable a todas las temperaturas El uso de aceite sintetico no altera los intervalos de cambio de aceite indicados El uso de aceites multigrado 5W 30 10W 30 etc en temperaturas mayores a los 40 F 4 C ocasionar amp un consumo de aceite mayor al normal Cuando utilice un aceite multigrado revise con mayor frecuencia el nivel de aceite del motor Si utiliza aceite SAE 30 en temperaturas infer ores a los 2 3 4 5 6 40 F 4 C ocasionara que el arranque sea mas dificil e incluso que se desbiele el motor debido a su inadecuada lubricacion interna Coloque el generador sobre una superficie nivelada El area limpia alrededor de aceite amarillo lena la tapa Quite el aceite Ilena la tapa Llene lentamente motor con aceite por el aceite lena abdr hasta que el nivel de aceite sea al grano de derramar Instale aceite amarillo Ilena la tapa y el dedo aprieta seguramente Verifique el nivel de aceite de motor antes de comenzar cada vez despues Si el nivel de aceite estQ debajo del punto de derramar Ilena al nivel apropiado NOTA Revise el aceite frecuentemente durante el despegue del motor Agregue Gasolina ADVERTENCIA CUANDO AI_ADA COMBUSTIBLE Apague el generador posici6n OFF y d_jelo enfriar al me
20. generador Desconecte todas las cargas electricas de generador Use as siguientes instrucciones para encender paso por paso en erden numerico 1 Asegt rese de que la unidad esta en una superficie piana IMPORTANTE Si la unidad no se arranca y utiliza en una superficie plan amp se pueden producir problemas de arranque y de parada durante el funcionamiento 2 Gire la v amp lvula del combustible a a posicion On 3 Coloque la palanca de choke en la posicion Choke 4 Coloque el interruptor balancfn a a poslci6n On en posicion On 5 Agarre la manilla de retrocese y hale lentamente hasta que puede sentir un poco de resistencia Luego hale rapidamente para encender el motor ADVERTENCIA Cuando arranque el motor tire lentamente del cable hasta sentir una resistencia y a continuacibn tire r amp pidamente de 61 para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos electricos conectados yen funcionamiento IMPORTANTE Si el motor se desborda coloque la palanca estranguladora en a posicion Run e intente arrancario hasta conseguirio 6 Mueva la pa anca de choke a la posicion Run una distancia corta a a vez por algunos segundos en un clima calido o algunos minutos en un clima frio Deje que el motor corra suavemente antes de cada cambio Opere con el choke en a posicion Run NOTA Si el motor arranca despues de tirar tres vece
21. interrupter de motor a la posici6n Off Apagado 4 Gire la v amp lvula a la posici6n Off Apagado PRECAUCION NO coloque la palanca estranguladora en la posiciSn Choke para parar el motor El motor podria petardear incendiarse o darlarse Conexion de Cargas Electricas NO conecte cargas de 240 Voltios a temacorrientes de 120 Voltics NO conecte cargas trifasicas al generador NO ccnecte cargas de 50 Hz a generader Deje que el motor se estabilice y se caliente per unos minutos despues del arranque Conecte y encienda las cargas electricas de 120 y o 240 Voitios AC menofasicas de 60 Hz que desse NO SOBRECARGUE EL GENERADOR Vea No Sobrecargue Generador I 39 JUEGOS DE CORDONES Y ENCHUFES CONECTORES _ PRECAUCION NUNCA intente suministrar corriente a un dispositivo de amperaje superior aI que puede suministrar el generador o el enchufe hembra NO sobrecargue el generador Consulte el apartado No Sobrecargue GeneradoP Use Qnicamente cordones de extension de alta calidad y bien aislados con los tomacorrientes electricos dobles de 120 Voltios del generador Revise las capacidades de todos las cordones de extensi6n antes de usarlos Los juegos de cordones de extension utilizados deberan tener una capacidad de 125 Voltios AC a 20 Amperios o mayor para la mayoria de los dispositivos electricos Sin embargo algunos dispositivos podrian no requerir este ti
22. lentamente del cable hasta sentir una resistencia y a continuaci6n tire r_pidarnente de el para evitar su retroceso NUNCA arranque o pare el motor cuando haya aparatos electricos conectades yen funcionamiente 33 ADVERTENCIA CUANDO ANADA COMBUSTIBLE O VACiE EL DEP6SITO Apague el generador posici6n OFF y dejelo enfriar al menos por 2 minutes antes de remover la tapa de la combustible Afloje la tape lentamente para dejar que la presi6n salga del tanque Llene ovacie el dep6sito de combustible a la intemperie NO Ilene demasiado el tanque Permita al menos especio para la expensi6n del combustible Mantenga la combustible alejada de chispas llamas abiertas pilotos calory otras fuentes de ignici6n NO encienda un cigarrillo o fume UANDO PONGA EN FUNCIONAMIENTO EL EQUlPO Compruebe que la bujia el silenciador el tap6n del dep6sito de combustible y el flltro de aire est_n instalados NO arranque el motor sin Ia bujia instalada Si se ha derramado combustible espere a que se evapore antes de arrancar el motor UANDO OPERE EL EQUIPO NO incline el motor o el equipo de tal manera que Ia combustible se pueda derramar NO estrangule eI carburador para parar el motor Este generador no es apto para el uso en equipos m6viles ni en aplicaciones marinas UANDO TRANSPORTE O REPARE EL EQUIPO Transporte o repare el equipo con el tanque de combustible vacio o
23. of the particular peice of power equipment the manner in which the engine is operated engine run in to reduce friction and clean out of combustion chambers adjustments to the valves and carburetor and other factors The power ratings may also be adjusted based on comparisons to other similar engines utilizedin similar applications and will thereforenot necessarily match the values derived using the foregoing codes PRODUCT SPECIFICATIONS Generator Specifications Rated Maximum Power 5600 Watts 5 6 kW Surge Power 8600 Watts 8 6 kW Rated AC Voltage 120 240 Volts Rated Maximum AC Current at 240 Volts 23 3 Amperes at 120 Volts 46 6 Amperes Rated Frequency 60 Hz at 3600 rpm Phase Single Phase Unit Weight 170 Ibs Engine Specifications Rated Horsepower 10 at 3600 rpm Bore 3 12 in 79mm Stroke 2 44 in 62mm Displacement 18 64 in 305 cc Spark Plug Type Champion RC12YC or Equivalent Set Gap To 0 030inch 0 76mm Armature Air Gap 0 008 0 012 in 0 20 0 30mm Valve clearance with valve springs installedand piston1 4 in 6 mm past top dead center check when engine iscold Intake
24. shown 11 Attach handle bracket with two M8 x 45mm cap screws and two locking hex nuts 12 Check that all fasteners are tight and the tires are inflated to the value marked on the tire or within 15 and 40 psi Wheel Kit Assembly View Cap Screw Handle Assembly Support Leg Hex Nut _ Cap Screw Axle Wheel Flat Washer E Ring Add Fuel WARNING BEFORE STARTING THE GENERATOR To operate the generator you will need to first add engine oil and gasoline as follows Add Engine Oil NOTE When adding oil to the engine crankcase use only high quality detergent oil rated with API service classification SF SG SH SJ or higher DO NOT use special additives 1 Choose a viscosity according to the table below _ L L J 1 J _F 20 0 2O 32 4O _0 8O 100 c _1 2b n i1o _ i o 2b _b 4 o STARTING TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE NOTE Synthetic oil meeting ILSAC GF 2 API certification mark and API service symbol with SJ CF ENERGY CONSERVING or higher is an acceptable oil at all temperatures Use of synthetic oil does not alter required oil change intervals The use of multi viscosity oils 5W 30 10W 30 etc in temperatures above 40 F 4 C will result in higher than normal oil consumption When using a multi viscosity oil check oil more frequently If using SAE 30 oil in temperatures below 40 F 4 C it will res
25. small off road engine or a part has failed due to abuse neglect improper maintenance or unapproved modifications You are responsible for presenting your small off road engine to an approved Sears Service Center as soon as a problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty rights and responsibilities you should contact a Sears Service Representative at 1 800 469 4663 Sears Emission Control Defects Warranty Provisions The following are specific provisions relative to your Emission Control Defects Warranty Coverage 1 Warranted Parts Coverage under this warranty extends only to the parts listed below the emission control systems parts to the extent these parts were present on the engine purchased In the USA and Canada a 24 hour hotline 1 800 469 4663 has a maintenance information Cold start enrichment system Carburetor and internal parts Fuel Pump b Air Induction System Air cleaner Intake manifold c Ignition System Spark plug s Magneto ignition system d Catalyst System Catalytic converter Exhaust manifold Air injection system or pulse valve e Miscellaneous Items Used in Above Systems Vacuum temperature position time sensitive valves and switches Connectors and assemblies 2 Length of Coverage Sears warrants to the initial owner and each subsequent owner that th
26. u otras aberturas en un espacio cerrado en el que puedan acumularse NO opere el generador dentro de un edificio o lugar cerrado incIuyendo el compartimiento del generador en un vehiculo recreativo o RV El generador debe estar situado a un minimo de 152 cm 5 pies de toda estructura con muros combustibles y o otras materias combustibles Mantenga un minimo de 92 cm 3 pies alrededor del generador incluido la parte superior para facilitar la ventilaci6n y el mantenimiento del generador SitL_eel generador en una zona bien ventilada que permita la eliminaci6n de los gases de escape mortales No instale el generador en lugares en los que los gases de escape se puedan acumular o entrar en un edificio que pueda estar ocupado AsegQrese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci6n u otras aberturas en un espacio cerrado en el que puedan acumularse Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicaci6n del generador TIpica GeneradorMostrada Salida del Escape 38 PARA ENCENDER EL MOTOR PRECAUCION Yea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas electricas Conecte tas cargas ei6ctricas en Ia posiciSn de apagado OFF luego encienda ON para su operaci6n Apague OFF las cargas electricas y descon6ctelas del generador antes de parar el
27. uso comercial para los fines de esta garantia Durante dicho perlodo de garantia SEARS reparara o reemplazara a su discrecion cualquier parte que haya sido encontrada defectuosa en examen previo realizado por SEARS bajo uso y servicio normal Las baterias de arranque y los elementos perecederos como bujias y filtros de aire que se desgastan con el uso normal no estan garantizados por SEARS Todos los costos de transporte bajo garantia incluyendo el envio a a fabrica de ser necesario seran responsabilidad del comprador y deberan ser pagados por anticipado Esta garantla no cubre el mantenimiento y servicio normal y no se aplica a generadores altemadores motores o partes que hayan sido sujetos a instalaciones o modificaciones incorrectas o no autorizadas mal uso negligencia accidente sobrecarga exceso de velocidad mantenimiento reparaci6n o almacenamiento incorrecto que a juicio de SEARS afecte negativamente su funcionamiento y confiabilidad DESGASTE NORMAL Como con todos los dispositivos mec amp nicos los motores necesitan el servicio y reemplazo peribdico de las partes para funcionar en buenas condiciones Esta garantia no cubre reparaciones cuando el uso normal haya sobrepasado la vida t_tilde una parte o motor NO EXISTEN OTRAS GARANTIAS EXPRESAS SEARS POR MEDIC DE LA PRESENTE DESCONOCE TODAS LAS GARANTIAS IMPLICITAS INCLUYENDO SIN LIMITARSE A AQUELLAS DE CO
28. 100 horas de operaci6n o una vez al afio Io que suceda primero ADVERTENCIA NO toque las superficies calientes Permita que el equipo se enfrie antes de tocarlo El generador debe estar situado a un minimo de 152 cm 5 pies de toda estructura con mutes combustibles y o otras materias combustibles Mantenga un minimo de 92 cm 3 pies alrededor de la carcasa del generador para facilitar ta ventilaci6n y el mantenimiento del generador En el estado de California es obligatorio segt_n la ley el use de apagachispas SecciSn 4442 del C_digo de Recursos P_blicos de California Otros estados pueden tener leyes similares Las leyes federales se aplican en tierras federales Si equipa el silenciador con un apagachispas este debera ser mantenido en buenas condiciones de trabajo Usted puede ordenar el apagachispas a trav6s de su distribuidor de servicio autorizado Sears NOTA Usted puede comprar los apagachispas a traves nuevos Ilamando al 1 800 366 PART El generador tendra que tener un apagachispas si Io usa en terrenos no tratados cubiertos de monte maleza o pasto El apagachispas debera ser mantenido en buenas condiciones por parte del propietario operador Limpie e inspeccione el apagachispas de la siguiente manera 1 Para retirar la protecci6n del silenciador retire los cuatro tomillos que conectan la proteccion a la mensula del silenciador MALLA DE APAGACHISPAS PANTALLA TERMICA
29. 900 4 37 10 6 54 26 25 8 11 22 8 2 31 14 2O CRAFTSMAN 5600 Watt AC Generator 580 325600 Main Unit Parts List Item Part 1 M194766GS 2 194150GS 4 190220GS 5 NSP 6 194151GS 8 96796GS 10 190274BGS 11 187365FGS 14 194729GS 15 695398 17 189008GS 18 60706GS 19 83083GS 20 B4986GS 21 194153GS 22 86494GS 23 86292GS 24 192794GS 25 191190GS 26 74908GS 31 77816GS 34 195422GS 35 194397GS 37 192376GS 40 194398GS 41 192980GS 44 193668GS 45 B4363GS 48 195373GS 50 188333GS 51 194799GS 52 189235GS 55 73054GS 58 190355GS 59 900 NSP Description CRADLE KIT Vibration Mount 45 Srv HOUSING Engine Adapter ASSY Alternator see page 24 KIT Hardware Mount Aptr WASHER M8 Flat SBHCS 3 8 16 x 1 0 Lg HHCS 5 16 24 x 7 44 KIT Muffler Bracket w Hardware GASKET Exhaust MUFFLER SCREW 5 16 18 x 3 4 SCREEN Spark Arrest DECAL Ground Green KIT Mount Vibration AIt Srv SCREW Wing M6 1 0 x 16 SCREW 10 16 x 3 4 Self Driller SHIELD Heat CAP SCREW M5 0 8 x 10 Taptite DECAL Hot Muffler COVER Bearing Carrier KIT Fuel Hose Formed Srv SCREW 12 24 x 1 2 THD Forming KIT Hardware Fuel Tank KIT Valve Tank Srv ASSY Tank Fuel Includes Items 41 50 51 amp 52 CAP Fuel Gauge WIRE Ground DECAL Gas Fill DECAL Danger DECAL Start Instructions DECAL Shut Off Fuel ASSY Control Panel
30. CARBURETOR GASKET SET 633 445 60_ 1005 59_ 65 _ 55 456_ 597D 689_ _ _j 459_ J 121 1211 f J 356A_ 356B 56__ 505 455 1 7 _ 305 27 ENGINE 10 HP Briggs and Stratton 204412 Parts List Item Part Description Item Part 1 695464 Cylinder Assembly 219 693578 2 495657 Kit Bushing Seal Magneto Side 220 691724 3 391086 Seal Oil Magneto Side 222 694866 5 697233 Head Cylinder 227 694864 7 694872 Gasket Cylinder Head 231 691636 11 696796 Tube Breather 286 695186 12 694953 Gasket Crankcase 304 697250 13 690360 Screw Cylinder Head 305 690960 15 691686 Plug Oil Drain 306 697204 16 694678 Crankshaft 307 691660 18 694951 Cover Crankcase 332 694685 19 495657 Kit Bushing Seal PTO Side 333 715231 20 391086 Seal Oil PTO Side 334 691061 21 281658 Cap Oil Fill 337 491055 22 695174 Screw Engine Sump 347 697854 23 694954 Flywheel 356 695366 24 222696 Key Flywheel 356A 695295 25 695457 Piston Assembly Standard 356B 692603 695458 Piston Assembly 010 Oversize 358 695438 695459 Piston Assembly 020 Oversize 364 695365 695460 Piston Assembly 030 Oversize 369 695422 26 694004 Ring Set Standard 425 694515 694006 Ring Set 010 Oversize 445 491588 694006 Ring Set 020 Oversize 455 694683 694010 Ring Set 030 Oversize 456 692299 27 690975 Lock Piston
31. ING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke VHEN STARTING EQUIPMENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before starting engine VHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes fuel to spill DO NOT choke carburetor to stop engine This generator is not for use in mobile equipment or marine applications VHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport repair with fuel tank EMPTY or with fuel shutoff valve OFF Disconnect spark plug wire VHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors WARNING DO NOT touch hot surfaces Allow equipment to cool before touching The generator must be at least 5 feet from structures having combustible wails and or other combustible materials Keep at least 3 feet of clearance on all sides of generator for adequate cooling
32. MERCIALIZACION Y ADAPTACION PARA UN PROPOSITO PARTICULAR AL EXTREMO PERMITIDO POR LA LEY LA DURACION DE CUALQUIER GARANTIA IMPLICITA QUE NO PUEDA SER DESCONOCIDA ESTA LIMITADA AL PERIODO DE TIEMPO ESPECIFICADO EN LA GARANTIA EXPRESA LA RESPONSABILIDAD LEGAL ES EXCLUIDA POR DAI_IOS CONSECUENCIALES INCIDENTALES O ESPECIALES BAJO CUALQUIERA DE LAS GARANTIAS Algunos estados no permiten limitaciones en la duraci6n de las garantias impllcitas o la exclusion o limitaci6n de dafios incidentales o consecuenciales por tanto las limitaciones o exclusiones anteriormente mencionadas podrian no aplicarse a usted Esta garantia le otorga derechos legales especlficos usted podrla tener otros derechos los cuales cambian de estado a estado Para servicio visite su centro de servicio de garantia autorizado SEARS mas cercano El servicio de garantia puede ser Ilevado a cabo _nicamente por un centro de servicio autorizado SEARS Esta garantia no se podra aplicar para servicio en otros centros de servicio Evidencia de la fecha de compra original debera ser presentada en el momento de solicitar el servicio de garantia SEARS ROEBUCK AND CO Department 817WA Hoffman Estates IL 60179 32 _k ste es el simbolo de alerta de seguridad Es usado para indicarle situaciones con peligros potenciales de lesion para el personal Siga las instrucciones de todos los mensajes de seguridad que aparecen despues
33. Manual del propietado Aceite para motor Tapon de fijacion Juego de Ilantas Consulte la ilustracibn mostrada e instale el juego de ruedas como se describe a continuaci6n 1 Coloque el fondo de la camilla del generador en una superficie plan amp Temporalmente coloque a unidad en bloques para ensamblada facilmente 2 Deslice el eje a traves de ambos soportes de montaje en el marco de la camilla como se muestra PARA RETIRAR EL GENERADOR DE LA CAJA Coloque la caja sobre una superficie piana y rigida con 4 las flechas que dicen this side up hacia ardba 5 Abra con cuidado las tapas superiores de la caja de envio Corte de arriba a abajo las esquinas de uno de los lados de la caja y co oque ese lado de la caja sobre el suelo 6 Retire todo el material de empaque relleno etc Saque el generador de la caja de envio 7 8 3 Deslice una rueda en el eje NOTA Aseg_rese de instalar ambas ruedas con la v amp lvula de aire hacia el lado de afuera MONTAJE DEL JUEGO DE RUEDAS El juego de ruedas esta disefiado para mejorar el transporte del generador NOTA Este Juego de Ruedas no ha sido diseSado para ser usado en la carretera 9 10 11 12 Coloque el e ring en la ranura de eJe Coloque un extremo de las pinzas de puntas de aguja en la parte inferior del eje y el otro extremo de las pinzas en la parte superior de e ring Asiente el e ring cerrando las pinzas Repi
34. OTOR Utilice un comprobador de bujias homologado NO comprueba la chispa sin la bujia instalada PRECAUCION NO cambie ninguna velocidad determinada El generador suministra una frecuencia y un voltaje calificado cuando funciona a una velocidad determinada NO modifique al generador en ninguna forma PRECAUCION Yea No sobrecargue generadof Encienda su generador y deje que el motor se estabilice antes de conectar las cargas el6ctricas Conecte Ias cargas el_ctricas en la posici6n de apagado OFF luego encienda ON para su operaci6n Apague OFF las cargas electricas y descon ctelas del generador antes de parar el generador PRECAUCION Use el generador solamente con la finalidad para el cual rue disefiado Si usted tiene alguna pregunta acerca de las fnalidades de uso del generador preg_ntele a su concesionario o contacte a Sears Opere el generador solamente en superfcies niveladas NO expenga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a traves de Ias ranuras de enfriamiento Si los aparatos conectados se sobrecalientan apaguelos y descon6ctelos del generador Apegue el generador si uSe pierde la salida el ctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva 34 CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEG
35. Owner s Manual ICRAFTSMAN I AC Generator Model No 580 325600 GENERATOR J CUSTOMER HELPLINE 1 800__ _ HOURS Mono FrL8am toSpm CT CAUTION Before using this product read this manual and follow all Safety Rules and Operating Instructions PRECAUCION Antes de utilizar el producto tea este manual y siga todas las Reglas de Seguridad e Instrucciones de Uso Sears Roebuck and Co Hoffman Estates IL 60179 USA visit our Craftsman website www craftsman com Part NO 191559GS Draft 10 03 01 2005 Safety Assembly Operation Maintenance Parts Espa_ol WARRANTY 2 SAFETY RULES 3 4 FEATURES AND CONTROLS 5 ASSEMBLY 6 7 OPERATION 8 11 SPECIFICATIONS 12 MAINTENANCE 13 15 STORAGE 16 TROUBLESHOOTING 17 SCHEMATIC DIAGRAM 18 WIRING DIAGRAM 19 REPLACEMENT PARTS 20 28 NOTES 29 EMISSION CONTROL WARRANTY 30 31 ESPAi_IOL 32 51 HOW TO ORDER PARTS
36. Pin 459 281505 28 696581 Pin Piston 493 694861 29 694691 Rod Connecting 505 691251 30 694692 Dipper Connecting Rod 552 694674 32 690976 Screw Connecting Rod 562 92613 33 499596 Valve Exhaust 564 692577 34 697464 Valve Intake 564A 692198 35 694865 Spring Valve Intake 592 690800 36 694865 Spring Valve Exhaust 597 691696 40 690694 Retainer Valve 604 697236 42 499586 Keeper Valve 606 695287 45 690977 Tappet Valve 615 694676 46 697239 Camshaft 616 694675 51 694874 Gasket Intake 632 695917 51A 694875 Gasket intake 633 690998 53 694869 Stud Carburetor 635 710901 55 695288 Housing Rewind Starter 689 691855 58 693389 Rope Starter Cut to Required Length 718 690959 59 805957 Grip insert 718A 695178 60 715257 Grip Starter Rope 741 691288 65 690837 Screw Rewind Starter 742 692564 95 691636 Screw Throttle Valve 746 694679 97 696387 Shaft Throttle 774 695447 98 695408 Kit Idle Speed 798 690967 104 694918 Pin Float Hinge 799 690297 105 696136 Valve Float Needle 799A 695446 106 696209 Valve Choke 868 690968 117 696134 Jet Main Standard 883 695398 118 696135 Jet Main High Altitude 914 693732 121 696146 Kit Carburetor Overhaul 950 695407 122 694876 Spacer Carburetor 966 692321 125 695918 Carburetor 975 696138 127 690727 Plug Welch 977 696147 130 696139 Valve Throttle 1005 694684 133 694914 Float C
37. Remplazar rnas a rnenudo bajo condiciones de suciedad o polvo RECOMENDACIONES GENERALES NOTA NO recomendamos el uso de mangueras de jardin para El mantenimiento periodico mejorara el rendimiento y prolongara la vida L_ti del generador Acuda a un distribuidor autodzado de Sears para reparar la unidad La garantfa del generador no cubre los elementos que hayan sido sujetos al abuso o negligencia del operador Para recibir el valor completo de la garantia el operador debera mantener el generador de la forma descrita en este manual Se deberan Ilevar a cabo algunos ajustes peri6dicamente para mantener correctamente su generador Todos los ajustes de le secci6n Servicio y Ajustes de este manual deberan ser hechos por Io menos una vez en cada estaci6n Cumpla con los requisitos de la tabla Programa de Mantenimlento descrita anteriormente NOTA Una vez al aSo debera limpiar o reemplazar le buj a y reemplazar el filtro de aire Una bujia nueva y un filtro de aire limpio garantizan una mezcle de combustible aire adecuada y ayuda a que su motor funcione mejor y tenga una vida L_tilmas prolongada CONTROL DE EMISIONES Cualquier establecimiento o individuo especializado en la reparacion de motores que no sean de automoci6n puede encargarse del mantenimiento la sustituci6n y le reparaci6n de los dispositivos y sistemas de control de emisiones Mantenimiento del Generador El mantenimiento del
38. URIDAD ANTES DE OPERAR SU GENERADOR Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes centreles y ajustes Conserve este manual para referencias futuras Tanque de Combustible Silenciador Apagachispas Palanca del Cebador Cortacircuitos Depurador de Aire Culatazo el Principio Tomacorrientes con Dispositivo de Seguridad de 120 240 Voltios AC 30 Amp Tuerca Mariposa para Conexi6n a Tierra Interrupter Balancin Tomacorrientes Doble de 120 Voltios AC 20 Amp Cortacircuitos AC Cada tomacorriente posee un cortacircuito para proteger el generador contra sobrecargas electricas Los cortacircuitos son del ripe oprimir para reposicionar Culatazo el Principle Use para comenzar motor Depurador de Aire Filtra el aire de entrada a medida que penetra en el motor Interrupter Balancin Debera estar en la posicion On En para darie arranque al motor Coloquelo en la posici6n Off Apagado para detener un motor en funcionamiento Palanca del Csbador Usada cuando se est amp dando arranque a un motor frio Silenciador Apagachispas El silenciador disminuye el ruido del motor y esta equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene una capacidad de 5 galones amedcanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltios AC 20 Amp Pued
39. a de combustible Cambio de Aceite Con el motor todavia caliente drene el aceite de la caja del cigQeSal Vuelva a Ilenado con el grado de aceite recomendado Aceite el Di amp metro Interior del Cilindro Quite la bujia y vierta aproximadamente 30 ml 1 onza de aceite de motor limpio en el interior del cilindro Coloque la bujla y arranque lentamente para distribuir el aceite ADVERTENCIA ia instalada Generador 1 Limpie el generador como esta descrito en la pagina 43 Limpieza del Generador 2 Revise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas Otras Sugerencias Para el Almacenamiento 1 NO almacene gasolina de una estaci_ n a otra 2 Reemplace la caneca de gasolina si comienza a oxidarse El oxido y o la suciedad en la gasolina le causara problemas 3 Si es posible almacene su unidad en un recinto encerrado y ct_brala para protegeda del polvo y la suciedad ASEGURESE DE VACIAR EL TANQUE DEL COMBUSTIBLE 4 Cubra su unidad con una cubierta de protecci6n adecuada que no retenga humedad 5 AImacene la unidad en un area limpia y seca ADVERTENCIA NO coloque una cubierta encima de un generador caliente Deje que la unidad se enfrie Io suficientemente antes de que le coloque la cubierta 46 Problemo El motor est_ funcionando pero no existe salida de AC disponsible El motor funciona b
40. adas pasado el punto muerto superior comprobar con el motor en frio Admision 0 10 0 15 mm 0 004 0 006 pulgadas Escape 0 10 0 15 mm 0 004 0 006 pulgadas Capacidad de Gasolina 5 galones amedcanos Capacidad de Aceite 0 8 litros 28 onzas Tipo de Aceite Sobre 40 F SAE 30 Debajo 40 F SAE 5W 30 o 10W 30 42 RESPONSIBILADES DEL CLIENTE Siga los intervalos horarios o de calendario Io aue ocurra orimero Se requiere de servicle con mayor frecuencia cuando opere le unidad en les condleiones adversas descritas a continuaci6n CALENOARIO DE MANTENIMIENTO ANOTE LAS FECHAS CONFORME INTERVALO DE OPERACION POR HORA CUMPLA CON EL SERVICtO NORMAL FEGHAS DE SERMICIO Antes de Cada 25 Cada 50 Cada 100 TAREA DE MANTENIMIENTO Cada Uso Horas o al ASO Horas o al Ano Horas o al Ano Verhqcar el nivel de aceite X Limpie los residuos X Cambiar e aceite del motor X _ Servicio al filtro de aire X Servicio a la bujia X Servicio al sistema de la buj a X Limpie el sistema de refrigeracion X z Prepar almacenamiento Si la unidad permanecer_ sin uso pot mas de 30 dlas Carnbiar el aceite despues de las prirneras 5 horas y despu6s carla 50 horas Hacer el carnbio de aceite con mayor frecuencia cuando trabaje en condiciones de rnucha suciedad o polvo
41. anty does not cover items that have been subjected to operator abuse or negligence To receive full value from the warranty the operator must maintain generator as instructed in this manual Some adjustments will need to be made periodically to properly maintain your generator All service and adjustments should be made at least once each season Follow the requirements in the Maintenance Schedule chart above NOTE Once a year you should clean or replace the spark plug and replace the air filter A new spark plug and clean air filter assure proper fuel air mixture and help your engine run better and last longer EMISSION CONTROL Maintenance replacement or repair of the emission control devices and systems may be performed by any non road engine repair establishment or individual GENERATOR MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust dirt moisture or any corrosive vapors Cooling air slots in the generator must not become clogged with snow leaves or any other foreign material Check the cleanliness of the generator frequently and clean when dust dirt oil moisture or other foreign substances are visible on its exterior surface NOTE DO NOT use a garden hose to clean generator Water can enter the engine fuel system and cause problems In addition if water enter
42. arburetor 1022 690971 135 696142 Tube Fuel Transfer 1023 697691 137 695426 Gasket Float Bowl 1026 695177 141 696208 Kit Choke Shaft 1029 690972 146 690979 Key Timing 1052 694858 161 694870 Base Air Cleaner 1052A 696954 163 692277 Gasket Air Cleaner 1070 691058 185 690958 Nut Air Cleaner Base 1095 695440 188 690877 Screw Control Bracket 1100 690973 192 690083 Bali Rocker Arm 1210 498144 209 694867 Spring Governor 1211 498144 Description Gear Governor Washer Governor Gear Bracket Control Lever Governor Control Screw Choke Valve Module Oil Sensor Housing Blower Screw Blower Housing Shield Cylinder Screw Cylinder Shield Nut Flywheel Armature Magneto Screw Magneto Armature Plug Spark Switch Rocker Wire Stop Wire Stop Wire Stop Gasket Set Engine Terminal Oil Plug Spring Float Bowl Screw Air Cleaner Cover Filter Air Cleaner Cartridge Cup Flywheel Plate Pawl Friction PawI Ratchet Bracket Mounting Nut Governor Control Lever Bushing Governor Crank Bolt Governor Control Lever Screw Control Cover Screw Control Cover Nut Rewind Starter Screw Pawl Friction Plate Cover Control Starter Rewind Retainer Governor Shaft Crank Governor Spring Link Mechanical Governor Seal Choke Throttle Shaft Boot Spark Plug Spring Friction Pin Locating Pin Locating Gear Timing Retainer E Ring Gear Idler Screw Stop Wire Screw Rocker Arm Screw Oil S
43. arks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke Protect Fuel System 1 Remove all gasoline from fuel tank to prevent gum deposits from forming on these parts and causing possible malfunction of engine 2 Run engine until engine stops from lack of fuel Change Oil While engine is still warm drain oil from crankcase Refill with recommended grade Oil Cylinder Bore Remove spark plug and pour about 1 ounce 30ml of clean engine oil into the cylinder Install spark plug and crank slowly to distribute oil Generator 1 Clean generator as outlined in Generator Cleaning 2 Check that cooling air slots and openings on generator are open and unobstructed Other Storage Tips 1 DO NOT store fuel from one season to another 2 3 4 5 Replace fuel can if it starts to rust Contaminated fuel will cause engine problems If possible store unit indoors and cover it to give protection from dust and dirt BE SURE TO EMPTY FUEL TANK Cover unit with a suitable protective cover that does not retain moisture Store generator in clean dry area WARNING DO NOT place a storage cover over a hot generator Let equipment cool for a sufficient time before placing the cover on the equipment 16 Problem Engine is running but no AC output is available Engine runs good at no load but bogs down when loads
44. d lawn mower is used 20 to 25 hours per year Therefore the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years The Air Index is a calculated number describing the relative level of emissions for a specific engine family The lower the Air Index the cleaner the engine This information is displayed in graphical form on the emisions label Emissions Compliance Period On Engine Emissions Compliance Label After July 1 2000 certain Sears engines will be certified to meet the United States Environmental Protection Agency USEPA Phase 2 emission standards For phase 2 certified engines the Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emission requirements For engines less than 225 cc displacement Category C 125 hours B 250 hours and A 500 hours For engines of 225 cc or more Category C 250 hours B 500 hours and A 1000 hours This engine has an intermediate rating with and Air Index of 3 The EPA Emissions compliance period is Category C The diplacement of this engine is 305 cc Below is a generic representation of the emission label typically found on a certified engine 31 GARANTIA 32 REGLAS DE SEGURIDAD 33 34 CARACTERiSTICAS Y CONTROLES
45. de este simbolo para evitar posibles lesiones o muerte _Lea este manual de manera cuidadosa y familiaricese con su generador Conozca sus usos sus limitaciones y cualquier peligro relacionado con el mismo El simbolo de alerta de seguridad _ es usado con una palabra PELIGRO ADVERTENCIA PRECAUCION un mensaje por escrito o una ilustraci6n para alertarlo acerca de cualquier situaci6n de peligro que pueda existir PELIGRO indica un riesgo el cual si no se evita causar_ la muerte o una herida grave ADVERTENCIA indica un riesgo el cual si no se evita puede causar la muerte o una herida grave PRECAUCI6N indica un riesgo el cual si no se evita puede causar heridas menores o moderadas PRECAUCI6N cuando se usa sin el simbolo de alerta indica una situaci6n que podria resultar en el dafio del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte ADVERTENCIA El escape del motor de este producto contiene elementos quimicos reconocidos en el Estado de California pot producir c amp ncer defectos de nacimiento u otros dahos de tipo reproductivo ADVERTENCIA Este generador no cumple la norma 33CFR 183 del cuerpo de guardacostas de EE UU y no debe utilizarse en aplicaciones marinas El uso de un generador no homologado pot cuerpo de guardacostas de EEUU pu
46. e Warranted Parts shall be free from defects in materials and workmanship which caused the failure of the Warranted Parts for a period of two years from the date the engine is delivered to a retail purchaser 3 No Charge Repair or replacement of any Warranted Part will be performed at no charge to the owner including diagnostic labor which leads to the determination that a Warranted Part is defective if the diagnostic work is performed at an approved Sears Service Center 4 Claims and Coverage Exclusions Warranty claims shall be filed in accordance with the provisions of the Sears Warranty Policy Warranty coverage shall be excluded for failures of Warranted Parts which are not odginal Sears parts or because of abuse neglect or improper maintenance as set forth in the Sears Engine Warranty Policy Sears is not liable to cover failures of Warranted Parts caused by the use of add on non original or modified parts 5 Maintenance Any Warranted Part which is not scheduled for replacement as required maintenance or which is scheduled only for regular inspection to the effect of repair or replace as necessary shall be warranted as to defects for the warranty period Any Warranted Part which is scheduled for replacement as required maintenance shall be warranted as to defects only for the period of time up to the first scheduled replacement for that part Any replacement part that is equivalent i
47. e additional regulations which must be observed Connecting to a Building s Electrical System Connections for standby power to a building s electrical system must be made by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground circuit fault interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator Generator Location Generator Clearance ILWARNING Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RV The generator must be at least 5 ft 152 cm from structures having combustible walls and or other combustible material
48. ean the cooling system per recommended intervals see Maintenance Schedule on page 13 Equally important is to keep top of engine free from debris See Generator Cleaning CLEAN 15 GENERAL The generator should be started at least once every seven days and allowed to run at least 30 minutes If this cannot be done and you must store the unit for more than 30 days use the following information as a guide to prepare it for storage Long Term Storage Instructions It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor fuel filter fuel hose or tank during storage Also experience indicates that alcohol blended fuels called gasohol ethanol or methanol can attract moisture which leads to separation and formation of acids during storage Acidic fuel can damage the fuel system of an engine while in storage To avoid engine problems the fuel system should be emptied before storage of 30 days or longer Follow these instructions WARNING WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK Store away from furnaces stoves water heaters clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors VHEN DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Drain fuel tank outdoors Keep fuel away from sp
49. ectrical devices Some devices however may not require this type of extension cord Check the owner s manuals of those devices for the manufacturer s recommendations Keep extension cords as short as possible preferably less than 15 feet long to prevent voltage drop and possible overheating of wires 120 Volt AC 20 Amp Duplex Receptacle Each receptacle is protected against overload by a single 20 Amp push to reset circuit breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current 120 240 Volt AC 30 Amp Receptacle This is a full capacity receptacle it can supply the generator s full rated output from this sole outlet The outlet is protected by two 20 Amp push to reset circuit breakers 4 Wire Cord Set fW Neutral Y Hot X Hot NEMA L14 30 Ground Green A NEMA L14 30 plug is used with this 240 Volt receptacle Connect a suitable 4 wire cord set to the plug and to the desired load The cord set should be rated for 250 Volt AC loads at 30 Amps or greater 10 DON T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enough rated running and surge starting watts for the items you will power at the same time Follow these simple steps 1 Select the items you will power at the same time 2 Total the rated running watts of these items This is the amount of p
50. ectuosa Agua en la gasolina Sobrecebado Mezcla de combustible excesivamente rica 7 Reemplace la bujia 8 Drene el tanque de gasolina Ilenelo con combustible fresco 9 Abra por completo el cebador y haga girar el motor 10 Contacte el Departmento de Servicio Sears 11 La valvula de corte de combustible 12 La valvula de entrada esta atascada esta cerrada 13 El motor ha perdido compresion 11 Contacte el Departmento de Servico Sears 12 Contacte el Departmento de Servicio Sears 13 Contacte el Departmento de Servicio Sears El motor se apaga en pleno Sin gasolina Llene el tanque de combustible funcionamiento 1 AI motor le hace falta potencia 2 1 La carga es muy alta Filtro de aire sucio El cebador fue abierto muy rapidamente Carburador con mezcla de aire combustible muy rica o muy pobre El motor no funciona continuamente o se detiene 2 1 Vea No Sobrerecarque Generador 2 Reemplace el filtro de aire 1 Mueva el cebador a la posicidn intermedia hasta que el motor funcione suavemente 2 Contacte el Departmento de Servicio Sears 47 Sears Roebuck and Co U S A Sears California Air Resources Board Consejo de Recursos sobre el Aire de California GARB por sus siglas en ingles y United States Environmental Protection Agency Agencia de Protecci6n Ambiental de EE UU EPA por sus siglas en i
51. ede provocar lesiones y daSos rnateriales Simbolos de Peligro y Significados Electrocutamiento Descarga Electrica Descarga Electrica N ll Explosi6n Fuego Gases T6xicos Superficie Caliente Retroceso ADVERTENCIA Opere el generador SOLAMENTE aI aire libre AsegOrese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci6n u otras aberturas en un espacio cerrado en el que puedan acumularse NO opere el generador dentro de un edificie o lugar cerrado induyende el cornpartimiento del generador en un vehiculo recreativo o RV ADVERTENCIA Cuando use un generador como poder de energia auxiliar notifique a Ia comparlia de utilidedes Use el equipo de transferencia aprobado para aislar el generador de otra utilidad electrica Use un interruptor para la faHa del circuito de tierra GFC0 en cualquier _rea bastante hOrneda o que sea altarnente condactiva tales corno terrazas de metal o trabaje hecho con acero NO toque los alarnbres pelados o recept_culos NO use un generador con cables electricos que esten malgastados rotos pelados o deSados de cualquier forms NO opere el generador baje la Iluvia NO rnaneje el generador o cables electricos rnientras este parad en agua descalzo o cuando las manos y los pies est6n mojados NO perrnita que personas descalificadas o nirlos operen o sirvan al generador ADVERTENCIA Cuando arranque el motor tire
52. el motor durante el almacenamiento Para evitar este tipo de problemas vacie el circuito de combustible cuando vaya a almacenar la unidad durante 30 dias o mas Vacie el dep6sito de combustible arranque el motor y dejelo funcionar hasta que los conductos de combustible y el carburador queden vacios Utilice combustible nuevo la pr6xima temporada Para obtener mas informaci6n al respecto consuite Aimacenamiento en la p amp gina 46 NUNCA utilice productos limp adores para motores o carburadores en el dep6sito de combustible ya que podrlan provocar daSos permanentes 37 COMO USAR SU GENERADOR Si tiene problemas operando su generador por favor Ilame a la linea de ayuda para generadores al 1 800 222 3136 Tierra del Sistema El generador dispone de una conexi6n a tierra del sistema que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA La tierra del sistema esta conectada al cable de CA neutro que a su vez esta conectado al bastidor del generador Requisitos Especiales Es posible que haya normas u ordenanzas locales y nacionales en materia de seguridad e higiene en el trabajo aplicables al uso del generador Consulte con un electricista cualificado un inspector electrico o el organismo competente En algunas zonas es obligatorio registrar los generadores en tas compaSlas electricas locales Si el generador se utiliza en una obra
53. en ser utilizados para suministrar alimentacion electrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminaci6n electrica de 120 Voltios AC a 20 Amperios monefasica de 60 Hz Tomacorriente con Dispositivo de Ssguridad de 1201240 Voltios 30 Amp Puede ser utilizado para suministrar alimentacion electrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminacion electrica de 120 y o 240 Voltios AC a 30 Amperios monofasica de 60 Hz Tuerca Mariposa de Conexion A Tierra Si requirio censulte con un electricista cualificado un inspector electrico o el organismo competente 35 Su generador requiere de ciertos procedimientos de montaje y solo estara listo para ser utilizado despues de habede suministrado servicio con el combustible y aceite recomendados Si usted tiene prob emas con el montaje de so generador por favor Ilame a a linea de ayuda para generadores al 1 800 222 3136 IMPORTANTE Cualquier intento de encender el motor antes de haber colocado el aceite recomendado resultara daSo del motor Necesitara una Ilave de cubos con cubos de 112 o 13mm y unas pinsas de punta para instalar el juego de ruedas CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no esta presente o esta daSada por favor liame a la linea de ayuda para generadores al 1 800 222 3136 La unidad principal
54. ensor Screw Oil Sensor Seal Valve Gasket Exhaust Screw Rocker Cover Screw Float Bowl Cover Air Cleaner Bowl Float Gasket Set Carburetor Fan Flywheel Gasket Rocker Cover Cover Rocker Rod Push Rocker Arm Sensor Oil Sensor Oil Screw Flywheel Fan Valve Gasket Set Pivot Rocker Arm Pulley Spring Assembly Pulley Pulley Spring Assembly Spring 28 29 Seam Roebuck and Co U S A Sears the California Air Resources Board CARB and the United States Environmental Protection Agency U S EPA Emission Control System Warranty Statement Owner s Defect Warranty Rights and Obligations EMISSION CONTROL WARRANTY COVERAGE IS a Fuel Metering System APPLICABLE TO CERTIFIED ENGINES PURCHASED IN CALIFORNIA IN 1995 AND THEREAFTER WHICH ARE USED IN CALIFORNIA AND TO CERTIFIED MODEL YEAR 1997 AND LATER ENGINES WHICH ARE PURCHASED AND USED ELSEWHERE IN THE UNITED STATES AND AFTER JANUARY 1 2001 IN CANADA California and U S EPA Emission Control Warranty Statement Your Warranty Rights and Obligations The California Air Resources Board CARB U S EPA and Sears are pleased to explain the Emission Control System Warranty on your model year 2000 and later small off road engine SORE In California new small off road engines must be designed built and equipped to meet the State s stringent anti smog standards Elsewhere in the United States new non road spark igni
55. esta rota Utilice una bujia de repuesto recomendada NOTA Puede adquirir nuevos bujia al m mero telef6nico 1 800 366 PART Proporcione Servicio al Depurador de Aire Su motor no funcionara correctamente y podria resultar dafiado si Io hace funcionar con un depurador de aire sucio Limpie o reemplace el filtro de papel del depurador de aire cada 25 horas de operaci6n o una vez al afio Io que suceda primero Limpielo o reemplacelo mas a menudo si la unidad funciona bajo condiciones de suciedad o polvo excesivo Atienda al Filtro del Aire 1 Afloje los tornillos y quite aire la cubierta mas limpia Quite papel el filtro 2 Instale iimpie o nuevo aire la asamblea mas limpia dentro de la cubierta Deshagase del filtro viejo apropiadamente Cartucho Cubierta Tornilios Base 44 3 Arme la cubierta mas limpia aerea en la base y apriete los tornil os NOTA Si necesita oredenar un flltro de papel nuevo per favor lame al 1 800 366 PART Carburador Si usted cree que su carburador necesita ajuste visite su centre de servicio Sears mas cercano El funcionamiento del motor podrla resultar afectado a altitudes per encima de 3000 pies Para operaciones a elevaciones mayores pongase en contacto con el centre de servicio Sears m amp s cercano Limpie la Pantalla Apagachispas El silenciador del escape del motor posee una pantalla apagachispas Inspeccione y limpie a pantalla cada
56. etlo para exteriores usted siempre debe tenet en cuenta que Sears podra nogar la cobertura de la garantia si su motor pequer_o para exteriores o una parte del mismo presenta fallas debido a abuso descuido mantenimiento incorrecto o modificaciones no aprobadas Usted es responsable de presentar su motor pequer_o para extedores a un Centro de servicio Sears aprobado tan pronto como se presente el problema Las reparaciones bajo garantla deberan concluirse en un perfodo razonable que no excedera de 30 dins Si fiene alguna pregunta con respecto a sus derechos y responsabilidades para la garantia pongase en contacto con un representante de servicio Sears al 1 800 469 4663 Disposiciones de la garantia de Sears contra defectos en el control de emisiones Las siguientes son disposiciones especfficas relacionadas con la cobertura de la garantla contra defectos en el control de emisiones 1 Partes garanttzadas La cobertura bajo esta garantla incluye solamente aquellas partes que se enumeran a continuacion Ins partes del sistema de control de em siones en a medida que dichas partes hayan estado presentes en el motor adquirido a Sistema de medicion de combustible Sistema de endquecimiento papa arranque en frfo Carburador y partes intemas Bomba de combustible b Sistema de inducci6n de aire Filtro de aire Colector de e
57. f necessa_ 4 Replace spark plug if electrodes are pitted burned or porcelain is cracked Use a recommended replacement plug NOTE You can purchase a new spark plug by calling 1 800 366 PART Service Air Cleaner Your engine will not run properly and may be damaged if you run it using a dirty air cleaner Clean or replace the air cleaner paper filter once every 25 hours of operation or once a year whichever comes first Clean or replace more often if operating under dusty or dirty conditions Service Air Filter 1 Loosen screws and remove air cleaner cover Remove paper filter Cartridge Cover Screw Base 2 Install clean or new air cleaner assembly inside cover Dispose of old filter properly 3 Assemble air cleaner cover onto base and tighten screws NOTE You can purchase new air cleaner elements by calling 1 800 366 PART 14 Carburetor If you think your carburetor needs adjusting see your nearest Sears service center Engine performance may be affected at altitudes above 3000 feet For operation at higher elevations contact your nearest Sears service center Clean Spark Arrester Screen The engine exhaust muffler has a spark arrester screen Inspect and clean the screen every 100 hours of operation or once each year whichever comes first WARNING DO NOT touch hot surfaces Allow equipment to cool before touching The generator must be at least 5 feet from st
58. g order You can order a spark arrester through your authorized Sears service dealer To Stop the Engine 1 Unplug all electrical loads from generator panel receptacles NEVER start or stop engine with electrical devices plugged in and turned on 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Move rocker switch to Off position 4 Move fuel valve to Off position CAUTION I DO NOT stop engine by moving choke lever to Choke position Backfire fire or engine damage could occur Connecting Electrical Loads DO NOT connect 240 Volt loads to 120 Volt receptacles DO NOT connect 3 phase loads to generator DO NOT connect 50 Hz loads to generator Let engine stabilize and warm up for a few minutes after starting Plug in and turn on desired 120 and or 240 Volt AC single phase 60 Hz electrical loads DO NOT OVERLOAD THE GENERATOR See Don t Overload Generator CORD SETS AND RECEPTACLES Use only high quality well insulated extension cords with the generator s 120 Volt electrical receptacles CAUTION NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator Check the ratings of all extension cords before you use them Extension cord sets used should be rated for 125 Volt AC loads at 20 Amps or greater for most el
59. generador consiste en conservar la unidad limpia y seca Opere y almacene la unidad en un ambiente Iimpio y sece donde no sera expuesta al polvo sucledad humedad o vapores corrosivos Las ranuras del aire de enfriamiento del generador no deben estar tapadas con nieve hojas o cualquier otro material extra_os Revise frecuentemente la limpieza de generador y limpielo cuando este con polvo sucio con aceite humedad o cuando otras substancias extraSas sean visibles en su superficie exterior 5mpiarel generador El agua podrla introducirse en el sistema de combustible del motor y causar problemas Ademas si el agua se introduce al generador a traves de las ranuras para aire de enfriamlento algo del agua quedara retenida en los espacios vacios y grietas del aislamlento del devanado del estator y rotor La acumuleci6n de agua y sucledad en los devanados intemce del generador disminuira eventualmente la resistencia del aislamlento de estce devanadce Limpieza del Generador Limpie a diarle o antes de cada uso los residuos acumulados en el generador Mantenga limpias las conexlenes los muelles y los mandos Umple todo resto de combustible de la zona que rodea al silenciador y de detras del mismo Mantenga limpios los componentes del generador para reducir el riesgo de sobrecalentamlento e ignicion de los residuos acumulados Utilice un trapo hQmedo para limpiar las superficies exteriores PRECAUCION NO exp
60. h use or at least every 5 hours of operation Keep oil level maintained Changing Engine Oil Change the oil after the first 5 hours of operation Change oil every 50 hours thereafter If you are using your generator under extremely dirty or dusty conditions or in extremely hot weather change the oil more often CAUTION Used motor oil has been shown to cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Change the oil while the engine is still warm from running as follows 1 Clean area around oil drain plug The oil drain plug is located at base of engine opposite carburetor 2 3 4 5 Remove oil drain plug and oil fill cap and drain oil completely into a suitable container Install oil drain plug and tighten securely Fill oil sump with recommended oil to the point of overflowing See page 7 for oil recommendations Install oil cap Tighten cap securely 6 Wipe up any spilled oil Clean Replace Spark Plug Change the spark plug every 100 hours of operation or once each year whichever comes first This will help your engine to start easier and run better 1 Clean area around spark plug 2 Remove and inspect spark plug 3 Check electrode gap with wire feeler gauge and set spark plug gap to 0 030 inch 0 76mm i
61. ha sido mostrado al cancer de ta piel de Ia causa en ciertos animales del laboratorio Completamente lavado expuso _reas con el jab6n y el agua _ ANTENGA FUERA DE ALCANCE DE NII_IOS NO CONTAMINE CONSERVE los RECURSOS VUELVA ACEITE USADO A la COLECCION CENTRA Cambie el aceite cuando el motor todavia se encuentre caliente despuds del funcionamiento como se indica a continuacibn 1 Limpie el area alrededor del tap6n para drenaje de aceite 2 Retire el tapon de drenaje de aceite y el tapon de Ilenado del aceite y drene el aceite por completo en un recipiente adecuado 3 Cuando haya drenano el aceite completamente instale el tap6n para drenaje de aceite y aprietelo firmemente 4 Llene con el aceite recomendado Vea Antes de Porter en Marcha el Generador en la pagina 37 para las recomendaciones del aceite 5 Instale el tapon de Ilenado del aceite y asegQrelo 6 Limpie cualquier derrame de aceite Limpe Reemplace la Bujia Cambie la bujia cada 100 horas de operaci6n o una vez al afio Io que suceda primero Esto ayudar amp a su motor a arrancar mas facilmente y a funcionar mejor 1 Limpie el area alrededor de la bujia 2 Retire y revise a bujia 3 Revise la separaci6n del electrodo con un calibrador de alambre y ajuste la separaci6n a 0 030 pulgadas 0 76ram si es necesario 4 Reemplace a bujia si los electrodos estan picados quemados o si la porcelana
62. hould not be used on marine applications Failure to use the appropriate U S Coast Guard approved generator could result in bodily injury and or property damage Hazard Symbols and Meanings Electrocution Electrical Shock Electrical Shock Explosion Fire Toxic Fumes Hot Surface Kickback WARNING Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings DO NOT operate generator inside any building or enclosure including the generator compartment of a recreational vehicle RV When using generator for backup power notify utility company Use approved transfer equipment to isolate generator from electric utility Use a ground circuit fault interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical cords which are worn frayed bare or otherwise damaged DO NOT operate generator in the rain DO NOT handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING When starting engine pull cord slowly until resistance is felt and then pull rapidly to avoid kickback NEVER start or stop engine with electrical devices plugged in and turned on WARN
63. iccion y limpiar las camaras de combustidn ajustes de las valvulas y el carburador etc Los valores de potencia nominal tambien se puede ajustar en funcion de las comparaciones con otros motores similares utilizados en aplicaciones similares por Io que no coincidira necesadamente con los valores que se obtienen al aplicar los codigos mencionados ESPECIFICACIONES DEL PRODUCTO Especificaciones del Generador Potencia Maxima 5 600 vatios 5 6 kW Potencia de Sobretension 8 600 Vatios 6 6 kW Voltaje Nominal AC 120 240 Voltios Corriente Maxima a 240 Voltios 23 3 Amperios Corriente Maxima a 120 Voltios 46 6 Amperios Frecuencia Nominal 60Hz a 3600 rpm Fase Monofasica Peso que Embarca 170 Ibs Especificaciones del Motor Caballos de Fuerza 10 a 3600 rpm Di amp metro de camisa 79 mm 3 12 pulgadas Carrera 62 mm 2 44 pulgadas Desplazamiento 305 cc 18 64 pulgadas Bujia Tipo Champion RC12YC o equivalente Calibrar Separaci6n a 0 030 pulgadas 0 76mm Entrehierro del inducido 0 20 0 30 mm 0 008 0 012 pulgadas Holgura de la valvula con muelles de valvula instalados y pistSn de 6 mm 0 25 pulg
64. ien sin carga pero funciona maY cuando se le contectan cargas 3 4 1 2 3 4 5 6 Causa 1 El interruptor automatico de circuito esta abierto 2 Conexidn real o defectuosa de juego de cables 3 El dispositivo conectado esta daSado 4 Averia en el generador 1 2 Corto circuito en una de las cargas conectadas El generador esta sobrecarga Velocidad del motor es muy lent amp Circuito del generador en corto Valvula del Combustible en posici_m Off Interruptor Run Stop poscioando en Stop Depurador de aire sucio Sin gasolina Gasolina vieja El cable de la bujla no esta en Accion 1 Reposicione el interruptor 2 Revise y repare 3 Conecte otto dispositivo que este buenas condiciones 4 Contacte el Departmento de Servicio Sears 1 Desconecte la carga electrica en corto 2 Vea No Sobrerecarque Generador 3 Contacte el Departmento de Servicio Sears 4 Contacte el Departmento de Servicio Sears 1 Gire la valvula del combustible a a posicidn On 2 Coloque del interruptor en Run 3 Limpie o reemplace el depurador de aire 4 Llenelo con combustible fresco 5 Drene el tanque de gasolina Ilenelo con combustible fresco 6 Conecte el cable a la bujla El motor no se enciende o se 7 enciende y funciona mal 8 9 10 malas la bujia Bujia def
65. l crankcase to proper level 11 Contact Sears service facility 12 Contact Sears service facility 13 Contact Sears service facility Engine shuts down during Fill fuel tank operation 1 Load is too high Engine lacks power 2 Dirty air filter 1 Choke is opened too soon Engine hunts or falters 2 Carburetor is running too rich or too lean 1 2 1 2 See Don t Overload Generator Replace air filter Move choke to halfway position until engine runs smoothly Contact Sears service facility 17 CRAFTSMAN 5600 Watt AC Generator 580 325600 BRIDGE RECTIFIER BLUE 2 RED 6 1 EXCITATIDN 4 FIELD BLUE RED BLACK GRAY BLUE ii RED BLACK 22 33 GRAY 44 BLUE IIA BLUF IIA BLUE IIA 22 120V 20A RED 22 O REB 22 120 240V 30A 22 BLUE IIA GRAY 44A 18 CRAFTSMAN 5600 Watt AC Generator 580 325600 CIRCUIT BREAKER 12 IIA 120 240V 30A CIRCUIT BREAKER 2 IIA IIA 4 120V 20A IIA 120V 20A I 22 IIA ii SIX LUG CONNECTOR HOUSING 22 IIA 33 22 22 _ ARNING TAB MUST NOT BE BROKEN BLACK 33 NOTE POSITIVE BRUSH 13 CLOSEST TO BEARING REB 2 61 CUSTONER GROUND LUG 19 CRAFTSMAN 5600 Watt AC Generator 580 325600 Main Unit Exploded View 50 44 45 52 51 gt 40 35 41
66. n performance and durability may be used in the performance of any maintenance or repairs The owner is responsible for the performance of all required maintenance as defined in this owner s manual 6 Consequential Coverage Coverage hereunder shall extend to the failure of any engine components caused by the failure of any Warranty Part still under warranty menu of pre recorded messages offering you product 3O Emissions Durability Period and Air Index Information On Your Engine Emissions Label Engines that are certified to meet the California Air Resources Board CARB Tier 2 Emission Standards must display information regarding the Emissions Durability Period and Air Index The engine manufacturer makes this information available to the consumer on emission labels The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant assuming proper maintenance in accordance with the Operating amp Maintenance Instructions The following categories are used Moderate Engine is certified to be emission compliant for 125 hours of actual engine running time Intermediate Engine is certified to be emission compliant for 250 hours of actual engine running time Extended Engine is certified to be emission compliant for 500 hours of actual engine running time For example a typical walk behin
67. ndica que los combustibles con mezclas de alcohol llamados gasohol etanol o metanol pueden atraer humedad la cual Ileva a la separaci6n y formacion de acidos durante el almacenamiento El gas acido puede daSar el sistema de combustible de un motor durante su almacenamiento Para evitar problemas del motor el sistema de combustible debera desocuparse antes de un almacenamiento de 30 dias o mas Siga estas instrucciones ADVERTENCIA CUANDO ALMACENE O GUARDE EL EQUlPO CON COMBUSTIBLE EN EL TANQUE Almacene alejado de calderas estufas calentadores de agua secadoras de ropa u otros aparatos electrodomesticos que posean pilotos u otras fuentes de ignici6n porque ellos pueden encender los vapores de la combustible UANDO VACiE EL DEP6SITO DE COMBUSTIBLE Apague el generador posicibn OFF y dejelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentamente para dejar que la presibn salga del tanque Vacie el dep6sito de combustible a la intemperie Mantenga la combustible alejada de chispas llamas abiertas pilotos calory otras fuentes de ignici6n NO encienda un cigarrillo o fume Proteja el Sistema de Combustible 1 Retire toda la gasolina del tanque de combustible para evitar que se formen dep_ sitos de goma en estas partes y causen posible mal funcionamiento del motor 2 Haga funcionar el motor hasta que se detenga por la falt
68. nglds Declaracibn de garantia del sistema de control de emisiones derechos y obligaciones del propietario para la garantia contra defectos LA COBERTURA DE LA GARANTtA DE CONTROL DE EMISIONES SE APLICA A LOS MOTORES CERTIFtCADOS ADQUIRIDOS EN CALIFORNIA EN 1995 Y POSTERIORMENTE QUE SE UTILICEN EN CALIFORNIA Y A MOTORES CERTIFICADOS MODELO 1997 Y POSTERIORES QUE SEAN ADQUIRIDOS Y UTILIZADOS EN OTRA REGION DE ESTADOS UNIDOS Y A PARTIR DEL 1 DE ENERO DE 2001 EN CANADA Declaracibn de garantla sobre el control de emisiones de la EPA de EE UU y California El Califomia Air Resources Board GARB la EPA de EEUU y Sears se complacen en explicar la Garantfa para el sistema de control de emisiones para motores pequef_os para exteriores SORE modetos afro 2000 y posteriores En California los nuevos motores pequetlos para extedores se deben disef_ar construir y equipar para cumplir con Ins estdctas normas det estado contra el smog En otras regiones de Estados Unidos los nuevos motores para interiores de ignicibn por chispa cerfificados para mogelos argo 1997 y posteriores deben cumplir con normas similares estal 4ecidas por la EPA de EE UU Sears debe garantizar el sistema de control de emisiones de su motor para Ios pedodos indicados a continuadbn siempre y cuando no se haya abusado descuidado o dado mantenimiento incorrect
69. nos por 2 minutos antes de remover la tapa de la combustible Afloje la tapa lentarnente para dejar que ta presibn salga del tanque Llene el dep6sito de combustible a la intemperie NO Ilene dernasiado el tanque Perrnita al rnenos espacio para la expansi6n deI combustible Mantenga la combustible alejada de chispas llamas abiertas pilotos calory otras fuentes de ignici6n NO encienda un cigarrillo o fume NOTA Este motor esta certificado para funcionar con gasolina Sistema de control de emisiones de gases de escape EM Modificaciones del motor 1 Utilice gasolina normal sin plomo limpia y nueva con un minimo de 85 octanos NO utilice combustible que contenga metanol ni mezcle aceite con combustible 2 Limpie el area alrededor de la tape de Ilenado del combustible retire la tape 3 Agregue lentamente gasolina regular SIN PLOMO al tanque de combustible Use un embudo para evitar que se derrame Llene el tanque lentamente hasta aproximadamente 1 5 por debajo de la parte la cima del cuello del tubo de Ilenado Combustible _NNNNNN_NNNNN_N_f 4 Instale la tapa del tanque de combustible y limpie la gasolina que se haya derramado iPRECAUCION Los combustibles con mezcla de alcohol gasohol etanol o metanol pueden atraer la humedad y provocar a separacion y formaci6n de amp cidos durante el almacenamiento Los gases amp cidos pueden da_ar el circuito de combustible y
70. ntana Calefactor de caldera 1 2 HP Cocina Homo de microondas 1 O0O Vatios Cafetera Cocina el6ctrica Elemento simple Calientaplatos Habitacibn Familiar Tocador de DVD CD VCR Receptor est6reo Televisor a color 27 pulg Computadora personal con monitor de 17 pulg Otros Sistema de seguridad Radio_Relo i AM FM Abridor de garaje 1 2 HP Calentador el6ctrico de agua 40 9alones Taller Luz de hal6geno para trabajar Rociador sin aire 1 3 HP Sierra intercambiable Taladro el6ctrico 1 2 HP Sierra circular 7 pulg Sierra inglete 10 pul9 Mesa de planificacibn 6 pulg Sierra de mesa sierra de brazo radial 10 pulg Compresor de aire 1 1 2 HP HP Caballo de fuerza Vatios Calificados cuando est_ funcionand o 75 5OO 8OO 8OO 1000 1200 3OO 8OO 1000 1500 1500 2500 100 100 450 5OO 8OO 180 3O0 480 4000 1000 6OO 96O 1000 1500 1800 1800 2000 2500 ratios Adicionales de Carga al encender 56O 1200 1600 2o00 1800 6o0 1300 520 1200 96O lO00 1500 1800 1800 2000 2500 El vataje que aparece en la lista es solamente una cantidad aproximada Verifique la herramienta o aparato electrico para obtener el vataje verdadero 41 INFORMACION TI CNICA SOBRE EL MOTOR El motor es de uno cilindros de valvulas en cabeza OHV refrigerado por aire y de baja emisidn En el Estado de California los motore
71. ntrada c Sistema de ignicion Bujlas Sistema de ignicion por magneto d Sistema catalizador Converfidor catalltico Colector de escape Sistema de inyecci6n de aire o v_lvula por impulsos e Distintos elementos utilizados en los sistemas anteriores V_Ivulas e interruptores de ratio temperatura posicion y de deteccion de fiempo Conectores y conjuntos 2 Vigencia de la cobertura Sears garanfiza al propietado inicial y a cada propietario subsiguiente que las partes garanfizadas estaran libres de defectos en material yen mano de obra que ocasionen fallas de las partes garantizadas durante un pedodo de dos afios a parfir de la fecha en que el motor sea entrogado al comprador minorista 3 NO habra cargos La reparadbn o reemplazo de cualquier parte garantizada se realizara sin cargo alguno para el propietario inciuyendo la mano de obra de diagnosfico que derive en la determinad6n de que una parte garantizada est_ defectuosa si la labor de diagnostico se realiza en un Centro de servicio Sears aprobado 4 Reclamos y exclusiones de cobertura LOS reclamos vinculados con la garantia se presentar_n conforme a las disposiciones de la Poliza de garantla de Sears La cobe_tura de la garantla se excluira para aquellas fallas de partes garantizadas que no sean partes originales de Sears o debido a abuso descuido o mantenimiento inc
72. o al motor pequer_o para extedores Su sistema de control de emisiones podra incluir partes como el carburador o el sistema de inyeccibn de combusfible el sistema de ignicion y el convertidor catalifico Tambien se pueden incIuir mangueras correas conectores y otros componentes relacionados con Ins emisiones Cuando exista una condicion que pueda set cubierta por la garanfia Sears reparar_ el motor pequeflo para extedores sin costo alguno incluyendo el diagnbstico las partes de repuesto y la mano de obra Cobertura de la garantia de Sears contra defectos en el control de emisiones LOS motores pequefios para exteriores modelos 1995 y postedores tienen una garanfia de dos atlos Si alguna parte de su motor relacionada con Ins emisiones est amp defectuosa Sears la reparara o sustituir amp Responsabigdades del propietario pata la garantia Como propietario deI motor pequeflo para exteriores usted es responsable de realizar las acfividades de mantenimiento reque0das que se indican en este manual del propietario Sears recomienda que conserve todos los recibos que cubran el mantenimiento de su motor pequer_o para extedores pero Sears no puede negar la garantla solamente pot la falta de recibos ni por su imposibilidad de garantizar la realizacion de todas Ins actividades de mantenimiento programadas Como propietario deI motor pequ
73. ograbados con informaci6n sobre mantenimiento de productos 48 Informacibn Sobre el Periodo de DurabUidad de las Emisiones y el Indice de Aire en la Etiqueta de Emisiones del Motor Los motores con certificaci6n de cumplimiento de a normativa sobre emisiones de nivel 2 del California Air Resources Board CARB deben mostrar informaci6n sobre el periodo de durabilidad de las emisiones y el indice de aire El fabricante del motor ofrece esta informacidn al consumidor mediante etiquetas de emisiones El Periodo de Ourabilidad de las Emisiones indica el n_mero de horas durante las cuales el motor puede funcionar cumpliendo las normas sobre emisiones siempre que se realicen las operaciones de mantenimiento que se detallan en las instrucciones de uso y mantenimiento Se utilizan las siguientes categorias Moderado El motor esta certificado para cumplir la normativa sobre emisiones durante 125 horas de funcionamiento real Intermedio El motor esta certificado para cumplir la normativa sobre emisiones durante 250 horas de funcionamiento real Prolongado El motor est amp certificado para cumplir la normativa sobre emisiones durante 500 horas de funcionamiento real Por ejemplo un cortacesped con operario a pie se suele utilizar entre 20 y 25 horas al aSo Por tanto el Periodo de Durabilidad de las Emisiones de un motor con clasificaci6n intermedia equivaldria a 10 12 aS
74. onga al generador a una humedad excesiva polvo suciedad o vapores corrosivos NO inserte cualquier objeto a traves de las ranuras de enfriarniento Puede usar un cepillo de cerdas suaves para retirar la suciedad endurecida aceite etc Puede usar una maquina aspiradora para eliminar suciedad y residuos sueltos Puede usar aire a baja presi6n que no exceda los 25 psi para eliminar la sucledad Inspecclene las ranuras para aire de enfriamlento y le apertura del generador Estas aperturas deberan mantenerse limpias y despejadas 43 MANTENIMIENTO DEL MOTOR ADVERTENCIA CUANDO AJUSTE O HAGA REPARACIONES A SU ENERADOR Siempre desconecte el alambre de la bujia y colbquelo donde no pueda entrar en contacto con la bujia UANDO PRUEBE LA BUJiA DEL MOTOR Utilice un comprobador de bujias homologado NO comprueba la chispa sin la bujia instalada Revision del Nivel de Aceite El nivel de aceite debera revisarse antes de cada uso o por Io menos cada 5 horas de operaci6n Conserve el nivel de aceite adecuado Cambio de Aceite del Motor y Filtro Cambie el aceite despues de las primeras 5 horas de operacion Cambie el aceite y el filtro cada 50 horas de ese momento en adelante Si est amp utilizando su generador bajo condiciones de extrema suciedad o polvo o en un clima demasiado caliente haga el cambio de aceite mas frecuentemente PRECAUCION El aceite usado del motor
75. orrecto segQn se establece en la P61iza de garanfia de motores de Sears Sears no es responsable pot la cobertura de Pallas de partes garantizadas ocasionadas por el uso de partes adicionales no originales o modificadas 5 Mantenimlento 6 Cualquier parte garanfizada cuyo reemplazo no este programado como mantenimiento requerido o que este programada enicamente para inspecci6n frecuente con el fin de reparar o reemplazar conforme sea necesario estara garantizada en cuanto a defectos pot ei perlodo de la garantia Cualquier parte garanfizada cuyo reemplazo este programado como mantenimiento requerido tendr_ solamente una garantla contra defectos Qnicamente por el pedodo hasta el primer reemplazo programado para esa parte Se podra utilizar cualquier parte de repuesto que tenga un rendimiento y durabilidad equivalentes al reatizar cualquier actividad de mantenimiento o reparacion El propietado es responsable de realizar todo el mantenimiento requerido segQn se define en este manual del propietario Cobertura consigulente La cobertura bajo la presente se ampliar amp a la falla de cualquier componente del motor provocada por un desperfecto en cualquier parte garantizada que sign gozando de la cobertura de la garantia En EEUU y Canada contamos con una linea de emergencia Ins 24 horns 1 800 469 4663 que ofrece un menQ de mensajes pr
76. os El indite de Aire es un valor calculado que indica el nivel relativo de emisiones de una gama concreta de motores Cuanto menor es el indite de Aire mas limpio es el motor Esta informaci6n se presenta en forma grafica en la etiqueta de emisiones Periodo de Cumplimiento de la Normativa de Emisiones en la Etiqueta de Cumplimiento de Emisiones del Motor Desde el 1 de julio de 2000 algunos motores Sears cuentan con la certificacion de cumplimiento de a fase 2 de las normas sobre emisiones de la United States Environmental Protection Agency USEPA Agencia estadounidense de proteccidn del medioambiente En el caso de los motores con certificaci6n de fase 2 el periodo de cumplimiento de la normativa sobre emisiones que figura en la etiqueta de cumplimiento de emisiones indica el nQmero de horas de funcionamiento durante las cuales el motor ha demostrado cumplir los requisitos federales sobre emisiones Para motores de menos de 225 cc Categoria C 125 horas B 250 horas y A 500 horas Para motores de 225 cc o m amp s Categorla C 250 horas B 500 horas y A 1000 horas La clasificacion de este motor es intermedia con un indice de aire de 3 El periodo de cumplimiento de la normativa sobre emisiones de la EPA es de categoria C El motor tiene una cilindrada de 305 cc A continuacidn se muestra una representaci6n generiea de la etiqueta de emisiones tipica de un motor certifieado
77. ots If connected devices overheat turn them off and disconnect them from generator Shut off generator if electrical output is lost equipment sparks smokes or emits flames unit vibrates excessively KNOW YOUR GENERATOR Read the owner s manual and safety rules before operating your generator Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments Save this manual for future reference FuelTank Spark Arrester Muffler not shown _ Fuel Valve not shown Circuit Breakers AC Choke Lever Air Cleaner 120 240 Volt AC 30 Amp Receptacle Recoil Handle Starter Grounding Fastener Rocker Switch on engine shroud 120 Volt AC 20 Amp Duplex Receptacles i May be used to supply electrical power for the operation of 120 Volt AC 20 Amp single phase 60 Hz electrical lighting appliance tool and motor loads 120 240 Volt AC 30 Amp Locking Receptacle May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air Choke Lever i Used when starting a cold engine Circuit Breakers AC Push to reset circuit breakers are provided to protect the generator against electrical overload 2 120 Volt AC 20 Amp Duplex Receptacle
78. ower your generator must produce to keep your items running See the table on the right 3 Estimate how many surge starting watts you will need Surge wattage is the short burst of power needed to start electric motor driven tools or appliances such as a circular saw or refrigerator Because not all motors start at the same time total surge watts can be estimated by adding only the item s with the highest additional surge watts to the total rated watts from step 2 Example Tool or Appliance Window Air Conditioner Refrigerator Deep Freezer Television Light 75 Watts Ra_d Running Watts 1200 800 500 500 75 3075 Total Running Watts Total Rated Running Watts Highest Additional Surge Watts Total Generator Output Required Additional Surge Starting Watts 1600 1600 500 1800 Highest Sure Watts 3075 1800 4875 Power Management To prolong the life of your generator and attached devices it is important to take care when adding electrical loads to your generator There should be nothing connected to the generator outlets before starting it s engine The correct and safe way to manage generator power is to sequentially add loads as follows 1 With nothing connected to the generator start the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine
79. po de cordon de extension Revise el manual del propietario de esos dispositivos para ver las recomendaciones del fabricante Mantenga los cordones de extension Io mas corto posible preferiblemente menos de 15 pies de largo para evitar la caida de voltaje y posible recalentamiento de los alambres Tomacorriente Doble de 120 Voltios AC Cada tomacorriente esta protegido contra sobrecargas por medio de un cortacircuito con dispositivo de reposicion Utilice cada uno de estos tomacorrientes para operar cargas electricas de 120 Voltios AC monofasicas de 60 Hz que requieran hasta 2 400 vatios 2 4 kW a 20 Amperios de corriente Tomacorriente de 120 240 Voltios AC 30 Amperios Este es un tomacorriente de capacidad total Io que significa que usted puede tomar el vatiaje nominal total de este solo tomacorriente Este es una tomacorriente tipo NEMA L14 30 La toma esta protegida por dos cortacircuitos de 30 Amperios con dispositivo de reposici6n 3 de Cable de 4 Alambres _ w Neutro X Cargado NEMA L14 30 _ Tierra Verde Usted deber amp usar un enchufe para conector tipo bloqueo NEMA L14 30 con el tomacorriente de 240 Voltios Conecte un juego de cordones de 4 alambres al enchufe y alas cargas electricas deseadas Los juegos de cordones deberan tener una capacidad de 250 Voltios AC a 30 Amperios 40 NO SOBRECARGUE GENERADOR Capacidad Usted debe asegurarse que su generado
80. puede ser necesario cumplir normas y requisitos adicionales Conexibn al Sistema Eldctrico de un Edificio Las conexiones a efectos de alimentaci_ n de reserva al sistema electrico de un edificio deben ser realizadas por un electricista cualificado La conexi6n debe aislar la alimentaci6n del generador de la alimentacion de la red pQblica y debe cumplir todas las leyes y normas electricas vigentes ADVERTENCIA Cuando use un generador como poder de energta auxiliar notifique a la compa_ia de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad electrica Use un interruptor para la falla del circuito de tierra GFCl en cualquier area bastante hQmeda o que sea altamente conductiva tales como terrazas de metal o trabajo hecho con acero NO toque los alambres pelados o receptaculos NO use un generador con cables electricos que esten malgastados rotos pelados o dar_ados de cualquier forrna NO opere el generador bajo la lluvia NO maneje el generador o cables etectricos mientras este parado en agua descalzo o cuando las manos y los pies est6n mojados NO permita que personas descalificadas o niSos operen o sirvan al generador Ubicacibn del Generador Espacio Libre Alrededor del Generador ADVERTENCIA Opere el generador SOLAMENTE aI aire libre AsegQrese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci6n
81. r puede proveer el suficiente vataje calificado cuando este funcionando y de carga al encender para los aparatos a los cuales va a proveer la energia al mismo tiempo Siga estos pasos 1 Seleccione los aparatos que recibiran la energia al mismo tiempo 2 Totalice los vatios calificados cuando este funcionando de estos aparatos Esta es la cantidad de energia que su generador debe producir para mantener eso aparatos funcionando adecuadamente 3 Calcule la cantidad de vatios de carga al encender que usted necesitar amp El vataje de carga es la cantidad minima de electricidad necesaria para encender herramientas o aparatos con motores electricos tales como sierras circulares o refrigeradores Debido a que no todos los motores se encienden al mismo momento el vataje total de carga se puede estimar al afiadir solamente el los aparato s con el vataje adicional mas alto al total del vataje calificado obtenido en el paso 2 Ejemplo Herramienta o Aparato EI6ct rico Aire Acondicionado de Ventana Refrigerador Congelador industrial Televisi6n Luz 75 Vatios Vatios Calificados cuando est6 funcionando 1200 8O0 5O0 5O0 75 Total 3075 Vatios para funcionar VatiosAdicionales de Carga al encende 0 1800 1600 500 1800 Vatios de Carga m_s alto Vataje Total Calificado cuando este funcionando 3075 Vataje de Carga Adicional mas alto 1800
82. rnator or engine or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in SEARS s judgment to adversely affect its performance and reliability NORMAL WEAR As with all mechanical devices engines need periodic parts service and replacement to perform well This warranty will not cover repair when normal use has exhausted the life of a part or engine THERE IS NO OTHER EXPRESS WARRANTY SEARS HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS SPECIFIED IN THE EXPRESS WARRANTY LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES UNDER ANY AND ALL WARRANTIES IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For service see your nearest SEARS authorized warranty service facility Warranty service can be performed only by a SEARS authorized service facility This warranty
83. ructures having combustible walls and or other combustible materials Keep at least 3 feet of clearance on all sides of generator for adequate cooling maintenance and servicing In the State of California a spark arrester is required by law Section 4442 of the California Public Resources Code Other states may have similar laws Federal laws apply on federal lands If you equip the muffler with a spark arrester it must be maintained in effective working order NOTE You can purchase a new spark arrester screen by calling 1 800 366 PART If you use your generator on any forest covered brush covered or grass covered unimproved land it must have a spark arrester The spark arrester must be maintained in good condition by the owner operator Clean and inspect the spark arrester as follows 1 To remove muffler heat shield from muffler remove four screws that connect guard to muffler bracket Spark Arrester Screen Muffler Heat Shield 2 3 Remove four screws that attach spark arrester screen Inspect screen and replace if torn perforated or otherwise damaged DO NOT use a defective screen If screen is not damaged clean it with commercial solvent 4 Reattach screen and muffler guard Air Cooling System Over time debris may accumulate in cylinder cooling fins and cannot be observed without partial engine disassembly For this reason we recommend you have an authorized Sears service dealer cl
84. s Oil Fill Fuel Tank i Capacity of five 5 U S gallons Fuel Valve Used to turn fuel on and off to engine Grounding Fastener i If required please consult a qualified electrician electrical inspector or local agency having jurisdiction Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switch Set this switch to On before using recoil starter Set switch to Off to switch off engine Spark Arrestar Muffler i Exhaust muffler lowers engine noise and is equipped with a spark arrester screen YourCraftsmangeneratorrequiressomeassembly andisreadyfor useonlyafterit hasbeenproperly servicedwiththerecommended oilandfuel If you have any problems with the assembly of your generator please call the generator helpline at 1 800 222 3136 IMPORTANT Any attempt to run the engine before it has been serviced with the recommended oil will result in an engine failure REMOVE GENERATOR FROM CARTON Set the carton on a rigid flat surface with up arrows pointing upward Carefully open the top flaps of the shipping carton Slice two corners at one end of carton from top to bottom and lay that side of carton down flat Remove all packing material carton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 222 3136 The main unit
85. s Leave at least 3 ft 92 cm all around generator including overhead for adequate cooling maintenance and servicing Place generator in a well ventilated area which will allow for removal of deadly exhaust gas DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Prevailing winds and air currents should be taken into consideration when positioning generator Typical Generator Shown Exhaust Port TO START THE ENGINE CAUTION See Don t Overload Generator Start generator and let engine stabilize before connectin electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator Disconnect all electrical loads from the generator Use the following start instruction steps by numerical order 1 Make sure unit is on a level surface IMPORTANT Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation 2 Turn the fuel valve to the On position J 3 _n _n _ Place the choke lever in the Choke position 4 Set the rocker switch to On position Rocker Switch is shown in the On position
86. s de la serie 200000 han obtenido la certificacidn del California Air Resources Board Consejo de recursos de aire de California de cumplimiento de la normativa sobre emisiones durante 250 horas Esta certificacidn no supone para el comprador el propietario o el usuario ninguna garantia adicional en Io relativo al rendimiento y a la vida Qtil del motor Las garantias del motor ataften exclusivamente al producto y a las emisiones que se declaran en este manual Potencia Nominal Los valores de potencia nominal de un modelo de motor se establecen en primer lugar con el cddigo J1940 Procedimiento de valoraci6n de potencia y par de pequefios motores Revision 2002 05 de la SAE Society of Automotive Engineers Sociedad de ingenieros de automocion Dada la amplia variedad de productos que utilizan nuestros motores y la multitud de factores ambientales que pueden afectar a su funcionamiento el motor que ha adquirido puede no legar a desarrollar su potencia nominal cuando se utilice con un aparato mecanico potencia real in situ Esta diferencia se debe entre otros a los siguientes factores diferencias de altitud temperatura presi6n barometrica humedad combustible lubricacidn del motor velocidad maxima controlada del motor variaciones entre distintos motores del mismo modelo dise_o del equipo mecanico utilizado manera de hacer funcionar el motor rodaje del motor para reducir la fr
87. s del arrancador pero no sigue funcionando o sila unidad se para en funcionamiento aseg_rese de que la unidad est amp en una superficie plana y compruebe que el nivel de aceite del cigflefial es correcto La unidad puede equiparse con un dispositivo de protecci6n de bajo nivel de aceite ADVERTENCIA NO toque las superficies calientes Permita que el equipo se enfrie antes de tocarlo El generador debe estar situado a un minimo de 152 cm 5 pies de toda estructura con muros combustib es y o otras materias combustibles Mantenga un minimo de 92 cm 3 pies alrededor de la carcasa del generador para facilitar la ventilaci6n y e mantenimiento del generador En el estado de California es obligatorio segen la ley el uso de apagachispas Secci6n 4442 de Cbdigo de Recursos PQblicos de California Otros estados pueden tener ieyes similares Las leyes federales se ap ican en tierras federales Si equipa el silenciador con un apagachispas este debera ser mantenido en buenas condiciones de trabajo Usted puede ordenar el apagachispas a traves de su distribuidor de servicio autorizado Sears Parado del Motor 1 Desconecte todas las cargas electricas de la unidad 2 NUNCA arranque o detenga el motor con dispositivos electricos conectados a el y encendidoe Permita que el motor funcione sin carga durante dos minutos para estabilizar las temperaturas internas de la unidad 3 Mueva el
88. s the generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Generator Cleaning Daily or before use clean accumulated debris from generator Keep linkage spring and controls clean Keep area around and behind muffler free from any combustible debris Generator parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris Use a damp cloth to wipe exterior surfaces clean CAUTION DO NOT expose generator to excessive moisture dust dirt or corrosive vapors DO NOT insert any objects through cooling slots Use a soft bristle brush to loosen caked on dirt oil etc Use a vacuum cleaner to pick up loose dirt and debris Use low pressure air not to exceed 25 psi to blow away dirt Inspect cooling air slots and openings on the generator These openings must be kept clean and unobstructed 13 ENGINE MAINTENANCE WARNING WHEN ADJUSTING OR MAKING REPAIRS TO YOUR _ ENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug VNEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed Checking Oil Level Oil level should be checked prior to eac
89. ta los pasos 3 por 5 para asegurar la segunda rueda Remueva los bloques temporales Para ayudar al ensamblaje de la pata de apoyo haga descansar el generador en la camilla con la parte del motor hacia abajo Anexe la pata de apoyo con dos tornillos M8 x 16mm y dos tuercas de seguridad como se muestra en la figura Use dos Ilaves de 13mm para apretar las piezas Ahora haga descansar el generador en las ruedas y pata de apoyo Coloque el soporte de la manilla en el centro del marco del generador al extremo de la pata de apoyo como se muestra Anexe el soporte de la manilla con dos tornillos M8 x 45mm y dos tuercas de seguddad Verifique que todas las piezas esten apretadas y las Ilantas esten infladas al valor marc5 en la Ilanta o dentro de 15 y 40 psi Vista del Montaje del Juego de Ruedas Tornillos Manilla Pata Tornillos Tuercas _ Eje Rueda Arandela E Ring 36 ANTES DE DARLE ARRANQUE AL GENERADOR Para operar el motor debera hacer la siguiente Agregar Aceite al Motor NOTA Cuando agregue aceite al compart miento del motor utilice L_nicamenteace re detergente de alta calidad designado con la clasificaci6n AP de servido SF SG SH SJ o superior NO use aditivos especiales Seleccione una viscosidad de acuerdo a la tabla siguiente ml L L J I J c _o 2b 1 o o 1_ 2b _ o Temperaturas de Uso Esperadas NOTA Todo aceite sintetico que
90. tion engines certified for model year 1997 and later must meet similar standards set forth by the U SEPA Sears must warrant the emission control system on your engine for the periods of time listed below provided there has been no abuse neglect or improper maintenance of your small off road engine Your emission control system may include parts such as the carburetor or fuel injection system the ignition system and catalytic converter Also included may be hoses belts connectors and other emission related assemblies Where a warrantable condition exists Sears will repair your small off road engine at no cost to you including diagnosis parts and labor Sears Emission Control Defects Warranty Coverage The 1995 and later small off road engines are warranted for two years If any emission related part on your engine is defective the part will be repaired or replaced by Sears Owner s Warranty Responsibilities As the small off reed engine owner you are responsible for the performance of the required maintenance listed in this owner s manual Sears recommends that you retain all your receipts covering maintenance on your small off road engine but Sears cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance As the small off reed engine owner you should however be aware that Sears may deny you warranty coverage if your
91. ult in hard starting and possible engine bore damage due to inadequate lubrication 2 Place generator on a level surface 3 Clean area around yellow oil fill cap Remove oil fill cap 4 Slowly fill engine with oil through oil fill opening until oil level is to the point of overflowing 5 Install yellow oil fill cap and finger tighten securely 6 Check engine oil level before starting each time thereafter If oil level is below the point of overflowing fill to proper level NOTE Check oil often during engine break in WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill fuel tank outdoors DO NOT overfill tank Allow space for fuel expansion Keep fuel away from sparks open flames pilot lights heat and other ignition sources DO NOT light a cigarette or smoke NOTE This gasoline engine is certified to operate on gasoline Exhaust Emission Control System EM Engine Modifications 1 Use clean fresh regular UNLEADED fuel with a minimum of 85 octane with equipment DO NOT use fuel which contains Methanol DO NOT mix oil with fuel 2 3 Clean area around fuel fill cap remove cap Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion as shown here YNNNNN_NNNNNNN_ 4 Install fuel cap and wipe up any spilled fuel