Home

RAB Lighting Mini Sensor Installation manual

image

Contents

1. motor loads such as kitchen appliances HVAC equipment washer dryer or garage door openers Sensor functions best when movement is across its detection pattern not towards the sensor Mount 6 10 high for optimum range and direction Less Sensitive More Sensitive Assembly and Wiring 1 Screw the threaded arm of the sensor into the center hold of the mounting plate Sensors can be wall or ceiling mounted 2 If mounting on the same cover plate as floodlight s screw the threaded arm s of each floodlight into the mounting plate Leave the locknuts and arm screws loose untill ready to aim Always mount the sensor below lights 3 Bring power leads and sensor leads into box 4 Attach ground wire s to outlet box grounding screw 5 Strip 1 2 of insulation from all leads Connect as shown in Wiring Diagram 6 Twist on wire nuts Secure with electrical tape 7 Align gasket to ensure proper seal Fasten mounting plate with sensor with two screws provided Use silicone sealant around all openings if necessary 8 Screw in light bulbs Turn on power 9 Conduct Walk Test to adjust sensor response Basic Wiring Diagram 5 4 The Mini Sensor infrared sensor sees small temperature changes caused by the motion of people or cars within its detection zone and turns on lights automatically It welcomes visitors and may deter intruders How long do the lights stay on Lights re
2. not recommended to wire sensors in parallel More than one sensor wired together makes them difficult to troubleshoot Disconnect multiple sensors and test separately 3 Keep all people completely out of the detection pattern to make sure the sensor is not detecting them 4 Make sure sensor is located below and as far as possible from its lights Heat from the lights may trigger the sensor Solution Move sensor below and away from the lights Technical Tips Lights Turn On and Off Incorrectly 13 12 1 Lights may turn on occasionally during rain snow and windstorms because the sensor is detecting changes in temperature If this is a constant problem mount the sensor in a more protected area 2 Tilt the sensor lower it may be seeing distant objects moving 3 You may not be aware that animals have triggered sensor Check sensor aiming to reduce nuisance triggering or mask the lower part of the lens with opaque weatherproof tape 4 The sensor may turn on occasionally during voltage surges 5 A possible source of mysterious sensor activations are strong local radio signals Check for nearby CB Ham VHF radio transmitters or Cellular telephones The sensor may be activated but will not be permanently impaired by these signals 6 Check other solutions mentioned under on pages 12 amp 13 Toll Free Technical Assistance If you need technical assistance please do the following 1 Re read th
3. sensor to operate both in low level light and at night turn the Photocell Control knob clockwise to the sun symbol 3 Check that lights from other sources such as adjacent porch lights garden lights streetlights or lights from inside the house are not in the sensor s view See 1 under Lights Turn Off Too Quickly 4 Was sensor wired hot If so circuitry may have been damaged 5 If sensor is painted make sure there is no paint on the lens and that the lens paint mask is removed 5 Make sure lights are not visible from or reflecting back into sensor Check for white or reflective surfaces close to the sensor Solution Aim sensor away from lights and reflective objects or mask the lens in the direction of the light or reflection 6 Heavy rain snow or high winds may activate the sensor occasionally Solution Reduce sensitivity control settings mount in a more protected area and or mask the lens if this is a constant problem 7 Make sure sensor is not aimed within 30 of a road or sidewalk Passing cars will activate sensor Solution Mask the top of the lens to reduce Detection Pattern Length 8 Self ballasted PL lamps may cause cycling on off 9 Check solutions 1 2 3 5 amp 6 under Lights Do Not Turn Off Pg 10 1 Make sure the sensor is installed on its own dedicated circuit free of motor loads such as HVAC equipment kitchen appliances or garage door openers 2 It is
4. when touched If it moves tighten all screws 3 Make sure that Mini Sensor is not mounted on an unstable object such as a tree or a pole that will move in the wind 4 Was sensor wired hot If so circuitry may have been damaged 5 Make sure sensor is not aimed within 30 feet of a road Branches blowing may activate sensor You may tilt sensor to not aim in the direction of the street or mask top of sensor lens to reduce range Pg 8 More sensitive Less sensitive Solution Mounting at 5 to 8 allows maximum range Technical Tips Lights Do Not Turn Off Technical Tips Range appears limited 20 No detection until here 11 10 4 Check that movement is not directly towards sensor Sensor will see movement across its pattern more quickly To fix move the sensor 5 Check that movement far away and directly towards sensor is not entirely within one Detection Pattern finger Problem Sensor will not detect until movement crosses from one finger into a second finger Solution Micro Adjust sensor by tilting sensor 1 16 This small adjustment may move the zones to allow earlier detection 1 Check if sensor is being tricked by reflected light If lights shine or reflect into the photocell located behind the lens the unit will go on briefly and turn off thinking it is daytime Problem Lights reflect into photocell or lights shine directly into photocell Solution Adju
5. ERWISE THE FOREGOING WARRANTIES STATE RAB S ENTIRE AND EXCLUSIVE LIABILITY AND BUYER S SOLE AND EXCLUSIVE REMEDY IN CONNECTION WITH THE PRODUCTS AND ALL PARTS THEIR DESIGN SUITABILITY FOR USE INSTALLATION AND OPERATION LIMITATION OF LIABILITY RAB shall not be liable under any theory of relief including without limitation breach of warranty breach of contract tort including negligence strict liability or otherwise arising out of or related to any breach of warranty any RAB products and the use thereof or any other acts or omissions of RAB for i any indirect incidental special or consequential damages whatsoever including without limitation loss of anticipated value of a business or its reputation or ii any damage or loss in excess of the price actually paid by buyer to the authorized RAB distributor for the products that caused the damages Any action by buyer must be commenced within one year after the cause of action has accrued Miscellaneous These product warranty terms shall be governed by the laws of the State of New York Buyer consents to the personal jurisdiction and venue of the courts of the State of New York Any legal or equitable claim of any nature arising hereunder shall be filed and maintained in the state or federal courts in the State of New RAB Lighting Product Warranties Technical Tips Lights Turn On For Unknown Reasons Masking the lens York and buyer agrees that such courts are a c
6. Installation Manual Mini Sensor Outdoor Motion Sensor 1 Smaller is better Mini Sensor uses state of the art surface mount technology SMT just like cellular phones and beepers SMT gives you more reliability greater RF immunity and a compact sensor that can fit neatly where others cannot Wider is better The wide 180 view detects movement along the entire side of a building with only one compact sensor It will detect people as they exit or enter It takes several conventional sensors to get the same coverage Molded is better No leaky gaskets or bug hotels with Mini Sensor The hard lens is molded as part of the case It s vandalproof rainproof bugproof and absolutely sealed Contents Relay On Off Model 500 Watts Incandescent 100 Watts Fluorescent at 120 Volts 5 Amps 450 Watts LED at 120 Volts with 0 8pF driver 5 Amps 300 Watts LED at 120 Volts with 0 5pF driver Voltage 120 Volts AC Power Consumption One watt UL Listing Raintight Photoelectric Switch Suitable for wet locations Time Adjustment 5 seconds to 15 minutes Quick Test Time 5 second test time for fast installation Works day or night Detection Zone Full 180 by 30 No Hands Auto Testing Auto mode starts after 3 minutes of testing No adjustment needed Built for Severe Conditions Double weatherproofing for long life Photoelectric Control Deactivates lights during daylight Fully adjustable for 24 hour ope
7. an or under the supervision of a licensed electrician and the product was in its original unopened and new condition at the time of installation RAB LIGHTING DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES WITH RESPECT TO ALL OTHER PRODUCTS INCLUDING WITHOUT LIMITATION PRODUCTS THAT HAVE BEEN PURCHASED FROM ANY PERSON OR ENTITY OTHER THAN AN AUTHORIZED RAB DISTRIBUTOR OR INSTALLED BY ANY PERSON OR ENTITY OTHER THAN A LICENSED ELECTRICIAN OR UNDER THE SUPERVISION OF A LICENSED ELECTRICIAN AND ALL PRODUCTS THAT ARE USED OR ARE OTHERWISE NOT IN THEIR ORIGINAL RAB LIGHTING PACKAGING AT THE TIME OF INSTALLATION Remedy RAB s obligations for breach of warranty shall be limited to repair or replacement at RAB s option of any products or parts which prove to be defective provided that buyer gives RAB written notice and returns the defective product to RAB in accordance with RAB s return material authorization RMA policies and RAB confirms the defect Buyer is responsible for all costs to de install defective products and re install replacement or repaired products and RAB shall not be liable for labor or other costs related to de installation or re installation DISCLAIMER THE FOREGOING WARRANTIES ARE IN LIEU OF AND RAB EXPRESSLY DISCLAIMS ALL OTHER REPRESENTATIONS GUARANTEES AND WARRANTIES EXPRESS OR IMPLIED IN FACT OR BY LAW INCLUDING WITHOUT LIMITATION ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTH
8. e Technical Tips sections of this manual 2 Call the Tech Help Line at 888 RAB 1000 8AM to 6PM Eastern Time M F and we will be glad to help you Before you call please have the following information handy The RAB Mini Sensor will be free from defects in materials and workmanship for a period of five 5 years from the date of delivery to the end user Sensors must be installed by a properly insured and licensed electrician or under the supervision of a licensed electrician and the product must be in its original unopened and new condition at the time of installation The information provided in the RAB Sensor Owner s Manual is critical in determining the location conditions intended use and other requirements with respect to the use and installation of a sensor product Using a sensor product in any manner other than as disclosed in the RAB Owner s Manual automatically voids the warranty Exceptions The above warranties shall not apply and RAB makes no representations or warranties with respect to a problems caused by acts of God including without limitation lightning strikes and b problems caused by any improper action or failure to act by any person or entity other RAB including without limitation problems caused by improper installation by the buyer an authorized RAB distributor or any other person or entity and c using or installing a sensor product in any manner other than as disclosed in the RAB O
9. ensor is mounted by a doorway at the top of stairs be aware that the elevated mounting height may extend the sensors range As distance from the sensor increases it will take more movement to be detected For instance at 10 feet a half step will be enough while at 30 feet several steps will be necessary Aiming and Walk Testing S T 8 Side View 30 Double Look Down Lens 60 30 Start Finish Photocell Turn to moon symbol for night only Turn to sun symbol for 24 hour operation lights turn on night and day 3 To reduce range use the lens masks provided or tilt sensor down Repeat steps 2 and 3 until you are satisfied with the coverage 4 The Time Control is factory set between 5 8 minutes This period starts after the movement in the Detection Zone ceases If less time is desired turn the time control counterclockwise For more time turn the control clockwise 5 The sensor is factory set for night only operation To obtain full operation 24 hours per day turn the Photocell Control fully clockwise to the sun symbol Intermediate settings will allow the sensor to operate earlier or later at dusk 6 Your sensor is ready for operation See the Technical Tips pages if additional help is needed Control Panel Turn controls gently using the adjustment tool provided Do not force past stops Top View 9 8 1 Check that the sensor is level from side to side and poin
10. eriod The sensor has a 3 minute Test Period which allows it to be aimed and walk tested day or night For the first 30 seconds the lights will be turned on During this time test that all fixtures and lamps function properly For the next 3 minutes the sensor will keep lights on for 5 seconds each time it detects movement in its Detection Zone The sensor will change to Automatic Mode after the 3 minute Test Period If another 3 minute Test Period is desired turn the power off for at least 10 seconds and back on again Walk Test The purpose of the Walk Test is to check and adjust the coverage pattern 1 Aim the sensor approximately to cover the area you desire 2 Start outside the Detection Zone and walk across the zone until the lights go on As distance from the sensor increases it will take more movement to be detected For instance at 10 feet a half step will be enough while at 30 feet several steps will be necessary Picking A Location Detection Pattern The sensor has a Double Look Down Lens with one Look Out zone and two Look Down zones for excellent detection both at long and close range Detection extends out a maximum of 30 feet and is 180 wide To reduce the Detection Pattern length aim the sensor down To reduce Detection Pattern width mask the sides of the lens with the Lens Mask Kit provided or opaque weatherproof tape If s
11. main on as long as there is movement within the Detection Zone Once the zone is vacated lights can be adjusted to remain on approximately 5 seconds up to 15 minutes Will the sensor detect animals Mini Sensor may detect large animals Having animals trigger the sensor can give property a lived in look You can limit animal detection by placing opaque weatherproof tape on the lower part of the lens or using the bottom mask on the Lens Mask Kit provided What does Manual Override do Keep lights on by flipping the wall switch two times within 5 seconds Sensor resets to auto mode at dawn No extra wiring needed Wiring Diagrams Sensors should not be installed on a circuit that also feeds motor loads such as HVAC equipment kitchen appliances or garage door openers If voltage varies significantly from 120 volts sensors may malfunction How Does RAB s Mini Sensor Work How are the Time Sensitivity and Photocell adjusted TimeControl Sets the time that lights will remain on after the Detection Zone is vacated from approximately 5 seconds to 15 minutes Use the adjustment tool provided to turn clockwise to increase the time Factory Setting 5 8 minutes Photocell Control For night only operation use the tool provided or a small screwdriver to turn the Photocell Control all the way counter clockwise to the moon symbol For operation in low level lights turn the knob all the way clockwise to the sun s
12. onvenient forum for adjudication In the event that suit is necessary to recover amounts owed RAB buyer shall be liable for reasonable attorney s fees interest and costs of collection No agreement or understanding varying the terms and conditions hereof shall be binding upon RAB or buyer unless in writing and signed by duly authorized representatives of both parties These product warranty terms shall inure to the benefit of and be binding upon the parties hereto and their respective successors and assigns RAB Sensor Warranty SMS500 IN 0314 Easy Installation amp Product Help Tech Help Line Call our experts 888 RAB 1000 2014 RAB LIGHTING Inc Northvale New Jersey 07647 USA rabweb com Visit our website for product info email Answered promptly sales rabweb com
13. ration or custom applications Vandal Resistant Lens Hard lens resists casual vandalism Case Construction Precision molded Lexan Color Matched Lens Dark lens with black units White lens with white units Surge Protection Withstands up to 3000 Volts Manual Override Double flip wall switch logic prevents activation by short power outages Resets to auto at dawn No extra wiring needed LED Detection Indicator Glows red day and night for on guard deterrence RF Immunity Circuits fully shielded for maximum radio frequency immunity Why RAB Sensors are BEST for You Specifications 3 2 Caution All wiring MUST comply with local electrical codes and should be installed by qualified electrician Read entire Installation Manual before proceeding TURN OFF POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER BEFORE INSTALLATION Total lighting load must not exceed 5 Amps 500 Watts incandescent quartz when sensor is used remotely 250 Watts when floodlights are mounted to sensor or 100 Watt fluorescent at 120 Volts or 5 Amps 450 Watts LED at 120 Volts with 0 8pF driver or 5 Amp 300 Watts LED at 120 Volts with 0 5pF driver To switch more wattage an electrician can install an additional relay Line Carrier Remote Control Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and cause false activations Do not install on circuits feeding
14. st Photocell Control slightly clockwise toward the sun symbol This allows the sensor to function in brighter ambient light conditions Alternatively move the lights or mask the lens in the direction of the lights or reflections If the problem persists it may be necessary to increase the lenth of the sun shield over the sensor using weatherproof tabe or some other material 2 Check if R lamps A lamps or self ballasted PL lamps are being used in a non enclosed lampholder that can be seen by the sensor If so switch to reflector PAR floodlight lamps or Quartz floods so the sensor is not affected by stray light If using PAR floodlights consider using lower wattage energy saving lamps Self ballasted compact fluorescent lamps may cause the sensor to cycle on and off Technical Tips Lights Do Not Turn On Lights Turn Off Too Quickly 1 Check that lamps and fixtures work Compare wiring to the Wiring Diagram in this manual Check that the power is on 2 If installing during daylight remember that the sensor will provide a 3 minute Test Period after power is turned on After 3 minutes the sensor will switch to Automatic Mode and will not work during daylight if the Photocell Control is turned to or near the night only position fully counter clockwise to the moon symbol If you require another 3 minute Test Period turn the power off for at least 10 seconds and back on again If you require the
15. ted at the area you desire If unit is tilted part of the Detection Zone may be high in the air over people s heads Solution Position sensor exactly level from side to side 2 Check that the sensor is not mounted too high If mounted above 20 feet much of the usable range will be lost 3 If sensor is painted make sure there is no paint on the lens and that the lens paint mask is removed Problem Passing cars activate sensor Solution A 20 safety zone between the sensor and road is recommended to avoid activation from passing cars 6 Make sure heat from lights is not triggering sensor Make sure the sensor is below and as far as possible away from lights 1 Make sure sensor is not aimed at something that would move or change temperature such as waving branches water air conditioners windows or heating vents even on neighboring property You can test for infrared sources in the area by placing a box or bag over the sensor Put sensor into Test Mode After the initial 30 seconds of the lights being on lights should stay off Wave your hand inside the bag in front of sensor Lights should go on and then time out If sensor operates properly when covered check items 2 6 Problem Sensor is triggered by unwanted movement or heat source Solution Tilt sensor Pg 8 or mask lens in the direction of the source Move sensor or source 2 Make sure sensor is mounted firmly and does not move even slightly
16. wner s Manual d use with Instant Start ballasts use with Instant Start ballasts will void the RAB warranty Out of warranty sensors replacement program If your sensor is out of warranty or if damage is unrelated to its original manufacture return your sensor freight prepaid and insured directly to us at RAB Lighting Inc 170 Ludlow Ave Northvale NJ 07647 with a check for 20 00 made payable to RAB Lighting Inc We will repair or replace your sensor promptly 14 15 Note These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation operation or maintenance a Catalog number of your unit b Wattage types and locations of lights connected to the sensor c The electrical circuit on which the sensor is installed What else does it feed How is the sensor power switched d Serial Number 4 digits on the back of the sensor e This installation Manual RAB Lighting cannot give electrical wiring instructions by phone Please consult a qualified electrician The following warranties apply to RAB Lighting Inc RAB products that meet all of the following conditions a the product was purchased by the contractor or end user from an authorized RAB distributor who purchased the product directly from RAB and from no other source b if the product has been installed the entire installation was performed by a licensed electrici
17. ymbol Adjust counterclockwise to have the sensor come on later at dusk clockwise to have it come on earlier Turning photocell control will show when the sensor thinks the current ambient light level night because the lights will turn on Factory setting Night Only Sensitivity Increases or decreases the responsiveness and range of the sensor Control Panel Turn controls gently using adjustment tool provided Do not force past stops S T Sensitivity Time Control Photocell Power Quality Wiring more than one sensor together is recommended only for the experienced installer because it becomes difficult to troubleshoot Single sensors that control their own lights pinpoint movement more accurately and operate better Multiple sensors To switch more than rated load To override sensor with a manual switch Masking the lens 7 6 Location Considerations Choose a location from which the sensor can see all the paths of movement that will be illuminated by its lights Mini Sensor may be wall or ceiling mounted Sensor functions best when the direction of expected movement is across its detection pattern not towards the sensor If wall mounting locate 6 10 high for optimum range and detection Lower mounting height will reduce range Sensor must be below and as far as possible away from lights If ceiling mounted be sure there are no lights below sensor Test P

Download Pdf Manuals

image

Related Search

Related Contents

  StarTech.com Round Head Replacement 6-32 Hard Drive Mounting Screws  Télécharger  GeBRAUChsANleiTUNG / MoDe D`eMPloi - rieder  Acte I : la politique de la ville  ITBURG - Tia.m.aT SystemworkS  YSI MultiLab 4010-1 & 4010P-1 Instruction Manual  Toasty Toes and Cozy Feet Leg Warmer Manual  取扱説明書 ` ` 保管用~  