1. Alarm sounds with LO indication abnormal low temp Humidity will not go high enough The machine makes some noise Itis normal that the machine emits some sounds because it uses air circulation fan for working Egg Turning fails to work Dew foams in the incubator Water leaks from the machine gt Check electric cord is properly connected gt Check if there is a power outage gt Check whether the plug is damaged gt Check your setting temperature gt Check the air circulation FAN is working gt Initialize the incubator Refer to the page 17 gt Check if room temperature is too high gt Check if incubator is exposed to the direct rays of sun gt Check if room temperature is too low gt Check if incubator heater temperature controlling system is normally working gt Check your setting humidity gt Close the view window again after checking gt Initialize the incubator Refer to the page 9 gt Check if there is any hatching debris such as feather or eggs shell in the incubator FAN gt Check that the Egg turning stoppage is not activated Egg turning lamp lighting gt Check that there are no foreign items on the egg turning tray gt Check if egg turning plate is assembled correctly Refer to the page 10 gt Check the incubator is not placed too cold circumstances gt When you turn OFF incubator and then turn on gt Check that you have not ove
2. H50 F244 10 H50 Hatching Option Pad RCM 347 10 USB Cable x Partly spare parts are not on the parts list Rcom is designed for user s easy and convenient use It can be changed without notice for improvement in performance design treatment and software etc DIGITAL INCUBATOR com SELLER MANUFACTURER RESME Head Office Deokam 612 Juchon Gimhae 621 843 KOREA TEL 82 55 337 2560 Direct to sales team 82 55 337 2561 3 Office FAX 82 55 33 2568 E MAIL Rcom Rcom co kr AUTOELEX Co LTD Rcom is the Best Design with High Quality Value and Performance
3. and display indicates current temp and temp difference alternatively How to Set Abnormal High Temp Setting When incubator temp is higher than setting temp Setting Range 0 5 C Default Setting 2C WEM High Temp Set WEM High Error When MENU screen is shown High T TEI SETUP p gt Temp Temp over S300 gt BACK button H CAL Hi rr LOErr and display return to basic screen Select with UP DOWN button Set with UP DOWN button How to Set Abnormal Low Temp Setting When incubator temp is lower than setting temp Setting Range 0 5 C Default Setting 3 MEM Low Temp Set Ime Ww Low Error When MENU ae ere ie screen is shown SET UP ress SET UP pack gt ie rip gt BACK button Ferm kere Wine and display return to basic screen Power Failure Alarm Function gt When you first switch on the power or in case of power failure during incubation display shows this icon 8 and incubator ES and incubator alarm sounds for about 10sec Press ENTER to remove DIGITAL INCUBATOR 1 Humidity amp Air Maintenance during Incubation 5 Incu bation Maintenance after Hatching 2 Dew Condensation Humidity amp Air Maintenance During Incubation gt When hatching humidity should be relatively high to prevent the thin membrane from drying out or hardening before hatching gt When hatching it s recommended not to open the lid often This is because if you open the lid
4. Small Standard For circulating warm air or Large egg tray A ti gt according to egg size Ai inet ver TT old separate Sold separately For inlet of air from outside Water hole To facilitate water top up for the humidity control Main Body 1 Locking Button Digital Control Center See description of Main Body 2 the function and operation M cc yn USB Cable Connecting Sockei Product Serial No Connecting the USB cable EX RCM0950278 You can set and store If you register your information incubation conditions Power Connecting Socket with your machine s serial with your Computer lt USB MODEL Only gt number on our web site www Rcom co kr you can get 2 year warranty service Connecting the electric cord 6 DIGITAL INCUBATOR 50 1 Introduction 4 Basic Components Basic Components Main Body 1 Main Body 2 Wm IN View Window Small Egg Tray Duplicated View Window Easy function operation Standard Egg Tray Can be attached anywhere for easy viewing lt USB MODEL gt O PC SOFTWARE CD Large Egg Tray Sold Separately Universal Tray Divider 10EA gt USB MODEL You can download updated information at www Rcom co kr DIGITAL INCUBATOR 5 Function of Digital Control amp 1 Introduction aes OEE Function of Digital Contr
5. H50 AGO1UH 10 H50 USB Body 20ASM mi H50 A601PL 10 H50 PRO Body H50 Main PCB ee St H50 A601PH 10 H50 PRO Body N H50 H618 10 Cover i 220ASM H50 A601ML 10 H50 MAX Body Seo 110ASM H50 A601MH 10 H50 MAX Body 220ASM AN G A H50 Humi ey I Heater Cover H50 A602 10 H50 Bottom ASM See H50 a610 10 H50 Humidity H50 H606 10 H50 A605L 10 H50 Heater Frame 110ASM RCM 700 10 Silicon Tube Heat Support A H50 AH604 10 50Window ASM ae Heat Support B i H50 PRO Main H50 A630L 10 H50 Silicon 110 H50 A604P 10 PCB ASM HEATER ASM H50 A604U 10 H50 USB Main H50 A630H 10 H50 Silicon 220 PCB ASM HEATER ASM y H50 Body Lock H50 A604M 10 H50 MAX MAIN H50 AH613 10 ASM i _ e x Partly spare parts are not on the parts list H50 A605H 10 H50 Heater Frame 220ASM Rcom USB 50 PRO 50 MAX 50 PART LIST Names of goods Compatible H50 H691 10 H50 Slider Roller H50 H616 10 H50 50Water Cap H50 Broodin H50 H608 10 Tray j Option For reptile incubator H50 Universal Tray RCM H623 10 ABS Divider 3 amp H50 H624 10 Option H50 Roller Divide H50 H810 10 O Ring 50 H50 H607 10 H50 Standard Tray H50 H620 10 H50 Large Tray Names of goods Compatible ea H50 MAX H50 H606M 10 Membrane SW H50 PRO H50 A606P 10 Membrane SW H20 Pinion Gear 330 Geard Motor Humi BLDC FAN40 BLDC FAN50 H20 304EU 10 Power Coard 8 H20 H686 10 H20 Rubber Foot
6. an incubation room 2 Before use Preparation for Incubation What s an Incubation Room Preparation for Incubation The Incubation Room is a confined space for setting and operating an incubator Because the incubation room environment has a considerable effect on hatch rate it s recommended to control the environment for setting up an incubator there should be little noise and vibration around and temperature ranging 28 C 82 4 F with small variation in temperature Especially if there are frequent occasions when the temperature drops suddenly at night compared with daytime be sure to check from time to time and pay attention so that the incubator is not directly exposed to s unlight during daytime in the back of the main body and put the main plug into a socket 1 Insert the electric cord in the connecting jack The LCD display will light up and show temperature Open the watercap and fill the hole with DISTILLED WATER and refill water after about 5 min again up to the limit line on its inside mark If you refill water during the incubation period humidity goes down temporarily A After filling up with water never shake or turn over the main body of the incubator which would cause water to spill inside the body and could cause a breakdown Please close the water cap properly after fiilng usp During incubation period check the DISTILLED WATER water levelabout every three days and refill water if necessary After you ref
7. from the back and attach to the window Easy Fu nction Ope ration x If you want to change setting value keep pressing SET button and change the value Automatic Mode Select i Incubation gt the Species of Bird Temp Setting Other Manual Mode gt Humid Setting Incubation Egg Turning Angle Setting Once Temp Setting How to change Setting 4 times Humidity Setting under Incubation 7 times Egg Turning Angle Setting 9 times Egg Turning Interval Setting Incubation Screen System finish Termination on Incubation Are you sure Gon Select YES gt Incubator Initialization Factory Setting Oe How to change How to turn off Humidification Function Screen MANUAL In case of low humidity on Incubation m incubation 4times Egg Turning Test Seng value DIGITAL INCUBATOR 1 How to Assemble the Incubator 2 Before use Egg turning plate How to Assemble View Window 4 gt Lock the four locking buttons at the front and rear of the 4 L006 incubator OGALOGA OGALOBALO OOOO OORO Standard Tray gt Insert the power cord in the socket at the back of the main body A Be careful when you assemble egg turning plate Egg Turning Plate gt If you do not assemble egg turning place correctly Main Body 2 it can cuase incubator failure gt Gear connecting part of egg turning plate must be on the top side DIGITAL INCUBATOR 2 What is
8. often humidity will be rapidly decreased and it will take a long time to regain the proper humidity A Incubator internal temperature is 37 99 5 F or more and hatching room temperature is below 28 C in that case RH70 humidity is may not be able The difference of 5 humidity value may occur from the humidity sensors difference and there are no problems at hatching gt It s very important to maintain humidity higher 1 3 days before uy hatching than the early and middle incubation periods Humidity a requirements during incubation are RH 45 55 for waterfowl RH 40 45 for poultry and RH 35 45 for parrot in general One day before hatching all kinds of birds need about RH 65 When the baby chickens hatch out humidity and sometimes need higher than that please move them into a brooder However in areas of high ambient humidity lower levels of humidity may be needed during incubation woe It s very important to keep humidity higher than RH 60 before hatching 3days x Air Controlling Lever Outer fresh air can be flowed into incubator inside without affecting insulation When eggs start hatching open air controlling lever either fully or half open Maintenance after Hatching gt It is necessary to use a brooder for baby chicken or bird since they are too week against cold or cool environment If you try egg hatching in your incubator there would be lots of germs feathers which causes of low egg hatching possib
9. E E Egg Turning Interval Incubation Start Notification During Incubation Incubation Date Setting v 16 DIGITAL INCUBATOR z a ial pag saad ahs al ORTO SO 3 Function Settings Oin Sloe Usaha Rati o Fado Setting Incubation start with PC connecting mode lt Rcom USB 50 MODEL ONLY gt Rcom pro 50 With this function you can share incubation process optimum incubation setting by building a database maua So S Gh o m 837 5 _ D o Bg 45x gt Refer to the PC Software Manual for starting incubation in PC connecting mode com PRo 50 gt During incubation press MENU button then you can Kir SB see a message as System finish Are you sure Incubation Termination gt Select YES with UP DOWN button and press ENTER 7 gt e Select with UP DOWN button Select C or F with UP DOWN button Return to factory setting gt When users have changed the incubator settings but want to return to factory setting Rcom pro 50 Chick gt Press SET UP button and select All Reset with UP DOWN button Then press ENTER au SF wp ley ae If you press ENTER button once again LCD display D o g 45x goes off with message amp alarm Incubator returns to factory setting after about 15 sec DIGITAL INCUBATOR LCD gt Display gt goes off Initialization after about 15sec 6 Incubation conditions reset 3 Fu nction Setti ngs How to Set Egg Turning Test Turn O
10. Love of life begins with Rcom S50 DIGITAL EGG INCUBATOR USER S MANUAL USB 50 PRO 50 o__ Mf Mg wW OTT a com Contents How to use Rcom USB 50 Recom PRO 50 1 Introduction 1 Recom 50 Introduction 4 2 Safety Precautions A 3 Identification of Parts 6 f Introduction 4 Basic Components E 5 Function of Digital Control amp How to Operate 8 6 SET UP Other Functions Easy Function Operation 9 1 How to Assemble the Incubator Egg Turning plate 2 What is an incubation room Preparation for Incubation _ 3 Incubation start for Other Birds Ci Function Settings 4 Incubation start with PC connection Mode 17 5 Incubation Termination Change Cels amp Fahr Return to Factory Setting 17 6 Incubation conditions reset How to Set Egg Turning Test How to Set Turn ON OFF Humidification Function 4 Other Functions 1 Egg Turning Check Alarm for water supplement Abnormal High or Low temperatue Alarm Power Failure Alarm Function 19 Other Functions 2 DIGITAL INCUBATOR Contents How to use Rcom USB 50 Recom PRO 50 fase er has name m e 2 Dew Condensation 20 1 How to Disassemble 21 2 How to Clean p7 1 Servicing Frequently Asked Questions FAQ 23 2 Troubleshooting 24 3 Specification 25 A The result of Hatching can be changed by a large numbers of factors Autoelex Co Ltd amp our distributors will no
11. N OFF Humidification Function Incubation Condition Reset during Incubation gt This is used when you want to change incubation setting mode again during incubation Rcomero S50 Press MANUAL button during incubation then Temp display will blink AN Ko SS If you want to change Temp reset with UP DOWN button SF wp A 3750 and then press ENTER to save Ca so 4 Using this method you can also reset humidity egg turning ENTER angle and egg turning interval If you do not want to change f setting just press MANUAL button then it passed to next stage Also it returns to incubation screen if you do not press any key for about 10sec gt You can go directly to the needed setting mode by pressing MANUAL button several times according to your needs It can be used when you want to check the current incubation condition during incubation gt If you press ENTER button LCD display indicates setting Temp amp Humidity Setting Save Message Egg Turning Test gt Press ENTER button for about 5sec during incubation RcomPRo 50 period to check egg turning we ESL y 4 gt If egg turning does not work check whether you assembled oO ABy the egg turning plate properly Refer to the page 10 Humidification Function ON OFF Setting gt You should turn OFF humidification function when you operate incubator without water or when you want to incubate with low humidity below 30 gt Press MANUAL button 4 time
12. a level surface A Be sure that the incubator works without any problem before placing eggs in the incubator DIGITAL INCUBATOR 7 Product Information 3 Specification TP 1 1 Name Rcom USB 50 Recom PRO 50 Specification 1 2 Model UX 50 PX 50 1 3 Supporting Soft Rcom USB 50 INCUBATION SYSTEM WINDOWS AC 100 120 V 50 60 Hz 220 240 V 50 60 Hz Working Temp 20 42 0 C i Working Humid Power Consumption Capacity Weight IK O Automatic automatic setting for each birds manual control available Temp Limits Manua 200 420 OOOO O Automatic Automatic setting foreach birds manual control available _ Humid Limits Mawa 30 70 It can be changed according to the conditions PROG PC 30 70 It can be changed according to the conditions Egg Turning Interval 15 Different from the egg tray Small 116 EA Quail egg size Small egg tray Standard 48 EA Chick egg size Standard egg tray Capacity Large 24 EA Goose egg size Large egg tray For all size egg Different from the species of egg Universal tray option PC Connecting Real time hatching condition transmission and setting control USB MODEL Incubator Upgrade N You will be asking for service charge if you are in below cases 1 Broken or Problem caused by No cleaning or Improper handling 2 Broken or problem caused by Not using distilled water 3 Broken or problem c
13. ate User can input the correct incubation date Initial settings depending on type of birds x Incubation date setting cannot be changed during incubation Setting Finish and Incubation Start gt After setting incubation date press ENTER button to start incubation with melody Incubation Start Notification During Incubation DIGITAL INCUBATOR 15 3 Incubation Start for 3 Function Settings Other Birds Incubation Start for other birds This function is used when user wishes to incubate other birds Rcom pro SO which are not memorized in the incubator menu setting User can change incubation conditions according to needs Vo o ee gt Press MENU button in basic screen gt Select Other Birds by UP DOWM button and then press ENTER to go to setting gt Set incubation date temperature humidity egg turning angel and egg turning interval with UP DOWM button and press ENTER button to save setting value Refer to the page 14 15 Rcom pro SOQ SEI D Day Humidity Setting Temperature Setting gt How to Set Consecutive Incubation Function On Incubation date setting raise incubation date up to D 50 and then press UP button one more then will be show and it starts Consecutive incubation Hr What is Consecutive Incubation Setting Egg Turning Angle Setting This function is used if you want to continue incubation without termination with same setting
14. aused by Trying Bird hatching in incubator Please don t try bird hatching in incubator Please use Hatcher during bird hatching 4 Broken or problem caused by Wrong controling Using 5 Broken or Problem caused by using the machine out of User s Manual 6 Broken or problem caused by Customer s mistake or fault x Register your product Serial No on our website for free 2 years gurantee x Refer to website for how to register Free 1 years gurantee in case not registerd x Product Registration Procedures If you are a new member of Rcom you need to log in our website at www Rcom co kr 1 Click SIGN UP on top of the right corner 2 Fill out the information on the blanks If you already registered your information on the Recom website please log in to www Rcom co kr 1 Click Login on top of the right corner 2 Select Customer and click Register Products 3 Fill out the information on the blanks You will need below information to register on our website 1 Your name 2 Your home company address amp Email address country 3 Your product model name amp Serial number 4 Date of purchase amp Name of purchased shop you bought from DIGITAL INCUBATOR Rcom USB 50 PRO 50 MAX 50 PART LIST Names of goods Names of goods Compatible Compatible H50 H601 10 5 Fo th H50 SMPS SS H50 A641 10 RCM A31 10 TH V2 Sensor H50 A601UL 10 H50 USB Body 110ASM
15. cause deformation or decoloration of the plastic parts gt When using humidification function a lot of alien matter sticks to the humidification heating element This may not cause failure but when terminating incubation please clean the humidifying heater lightly with a soft brush gt If you place the main body upper part on the floor please don t let the humidification heating part touch with the floor A If you inflict impact on the humidification heating part or scrape it with a sharp instrument the humidifying heater will be damaged A We kindly recommend you to use distilled water In order to reduce a foreign substance on the humidifying heater device DIGITAL INCUBATOR 6 How to Clean 2 How to Clean Start the vacuum cleaner to remove the dust as shown on the right and thoroughly shake out the minute dust with a fine brush If the incubator goes through incubations several times feather dust shell etc accumulate inside the main body which may cause a break down so be sure to clean the product before storage A In case the incubator clean status is poor which may cause fan noisy or stopping Cleaning the fan If you finish cleaning the incubator reassemble it in the reverse order of disassembly Wipe out outside the main body with a wet cloth and dry it in a cool and well ventilated place before storage ua Refer to How to assemble on Page 10 Don t clean the pr
16. designed easy to use and simple to use as a customer orientated product but please remember that the user s incubation knowledge and proper operation are very important for the best incubation result Therefore be sure to read this user s manual carefully before you use this incubator The Rcom 50 offers optimum incubation conditions but users need to observe and manage all incubation conditions such as species of eggs temperature or humidity for each incubation period and an optimum incubation circumstances Main Features LCD display with incubation information and animation graphic design Micro chip with optimum incubation conditions according to the species of birds for incubation beginners Manual setting Mode for incubation specialists Outer Temp Sensor included for Automatic Adjustment of Heating rate responding to Incubation Room Temperature Superior design with convenient operation Optimum air circulation technique with 5 strong BLDC fans Automatic Temp amp Humidity setting and control Body locking device Water supplement alarm function 48 eggs capacity for chicken size eggs 116 Quail egg size 24Goose egg size Antiblastic Humidification method by heating water which discourages bacterial growth Double glazed view window for minimizing the influence of outside temperature Enhanced reliability by applying Swiss s Sensirion s 3rd generation temperature amp humidity sensor Strong SMPS ap
17. e final stage of incubation ENTER button Setting of egg turning angle of Egg turning angle setting i early and middle stages of incubation Setting of date of egg turning angle change MENU button in the final stage of incubation a Setting of egg turning interval of Incubation termination UP DOWN button Egg turning interval setting i early and middle stages of incubation under incubation yes selection Setting of incubation date ENTER button incubation termination MENU screen basic screen before Screen showing Screen showing incubation Screen showing starting incubation incubation is in progress of other birds isin progress completion of incubation Incubation starts Incubation start with Automatic Mode The optimum incubation environment of the birds on the menu screen is memorized in the micro chip User can incubate easily using this function t gt k ACOM PRO 39 Duck Quail Pheasant enoni START to uc eafow Chick re A Goose Others Birds WildGoose Turkey Gold Pheasant gt Press MANUAL button to select species of birds in basic screen gt Select species of birds and press ENTER button for about 2sec then it starts incubation with automatic mode re l l ipy In auto incubation user only needs to select type of birds as incubation environments such as optimum temperature humidity egg turning etc are automatically controlled User can change incubation environments if needed C
18. erent from the setting angle depending on egg tray based on standard egg tray and size of eggs In general the egg turning angle of early and middle stages is 90 for chicken golden pheasant pheasant It is better to set higher angle 110 180 for bigger eggs and wild birds It is a general practice not to turn eggs turn angle is 0 at final stage of incubation 3 days before expected hatching date Egg Turning Angle Setting a When rnd Random is set the egg turning angle is between 75 180 at random Egg turning angle setting range 0 15 30 45 150 165 180 rnd If having difference for the egg turning angle between display and actual operating Please find and select the proper angle Egg turning interval setting Setting of egg turning interval of Setting of incubation date early and middle stages of incubation gt It is a function to set the interval time of egg turning It turns the eggs with the setting angle of early and middle stages every 60min User can optionally set the egg turning interval of eggs Initial Setting 60min gt rnd Random setting is for operating at random within the limits from 10min to 360min Egg turning interval setting range rnd 10 20 30 40 gt Egg luming interval Incubanon Date Sermng 340 350 360min gt Setting of incubation date The incubation date of birds on menu screen is a general incubation d
19. f humidity of Setting of humidity of Setting of date of humidity change early and middle stages of incubation final stage of incubation in the final stage of incubation gt The optimum humidity depends on type of birds However the humidity of final stage 3 days before incubation is generally higher than that of early and middle stages of incubation Default settings 45 60 3days Tips It is recommended to raise the humidity setting to over 60 from 1 3days before hatching In areas of high ambient humidity the humidity may not need to be raised until the last half day Humidity Settin after the chick is into the air space at the end of the egg y 9 ipy Temperature and humidity is optimized when Rcom products are released We do no recommend customers to recalibrate by their own If you need to recalibrate please visit our website www rcom co kr Download Manual or ask purchase place Because of low price thermometers and hygrometers are not accurate e recommend you to use special calibrated thermo hydrometer Poultry only thermo hydrometer check Rcom website Digilog Il DIGITAL INCUBATOR 50 Q Function Setting 2 Incubation start with Manual Mode Egg turning angle setting Setting of egg turning angle of Setting of date of egg turning angle change early and middle stages of incubation in the final stage of incubation gt The egg turning angle showing on LCD screen may be diff
20. hicken DIGITAL INCUBATOR 2 Incubation start 3 Function Setting with Manual Mode Incubation start with Manual Mode This mode helps users to set temp humidity and egg turning etc according to their needs This mode is ideal for those persons who are experienced in incubation gt Press MENU button on basic screen ER RcomprRo SO So SS A gt Select the species of birds with UP DOWN button Vo Rar 5 and press ENTER button then it goes to incubation O so 45 conditions setting mode gt Set required temp humidity and egg turning angle amp interval with UP DOWN button and press ENTER button to pass to next step Rcom PRO SO a p ae Une If there is no proper option please select option other Pheasant bird Refer to Page16 Peafowl x Goose x Wildgoose ETF Temperature setting Setting of temperature of 2 Setting of temperature of 3 Setting of date of temperature change early and middle stages of incubation final stage of incubation in the final stage of incubation gt Optimum incubation temperature of general birds at early and middle stages is 37 5 C and the temperature of final stage is better to set at 37 C three days before the expected date of hatching D Day User can optionally change the temperature of early middle and final stages of incubation Default settings D 37 5 C 37 0 C 3days Temperature Setting aiarra Humidity setting Setting o
21. ility for your next hatching Also they can make your incubator broken or faulty We strongly recommend you to use independent Hatcher or Brooder for egg hatching If you have any faulty or broken because of not using independent Hatcher or Brooder we do not serve you the free warranty service In other words you have to pay for the service charge To make a simple Hatcher or Brooder please refer to the our web site www Rcom co kr A Please do not try to egg hatching in the incubator It makes your incubator broken or faulty and we do not give you free warranty service Please move all the eggs 1 3 days before hatching into Hatcher or Brooder woe Hatcher The machine for egg hatching Operate it 1 3 days before egg hatching Rcom MARU H amp B Brooder The machine makes baby chickens or birds warm up against cold or cool environment You can set up proper temperature and humidity Rcom MARU H amp B Rcom Brooder Series gt As there is some difference in chick feed for each kind of bird so it s desirable to obtain useful information about the chicks before hatching Be sure to use a three wavelength 20W bulb If you use a bulb over 20W temperature goes up possibly killing the chick or causing a fire If there is too much water and a chick would falls into water its feathers get wet and it can be died of loss of body heat Here dry feathers with a hairdryer etc Be sure to use a three wavelength 20W bulb In case breeding room si
22. ill water check again after 5min and refill again A In case you use the incubator without adding humidification water or intend to incubate eggs at low humidity under RH 30 you must stop its humidification function please turn off the humidity unit if the unit is empty water otherwise humidity unit will be broke or you may not no longer use the unit When using this function the alarm for sensing water drop will go out See the description of humidification function OFF on Page 18 x How to turn off Humidification Function Set humidity level at RH 30 DIGITAL INCUBATOR 2 Before use 2 What is an incubation room 5 Preparation for Incubation A Some gap about 2mm around the eggs is needed for easy egg turning as shown on the below Y x When you use the universal rolling divider which is sold separately be careful to adjust the distance of rolling divider so that eggs do not roll out of position Refer to the picture rignt side A If you use Mineral water or Tap water for humidification the humidity unit can be broken easily because of water scales We strongly recommend you to use only DISTILLED WATER for your machine and Autoelex Co Ltd amp our distributors do not indemnify for warranty service not only if you have any problem with using mineral water regular water tab water and the like but also if you had improper management or handling for your machine In this case Autoelex C
23. o Ltd amp our distributors will charge for your after service 7 You can buy the Distilled water in your local market and if you have any question please contact the shop where you purchased your machine Place the eggs to incubate in the egg groove and A eo Tipy then close the view window Be careful to close the view window completely if not the temperature and humidity will fail to go up The egg to incubate must be a fertilized egg Refer to the guidebook lt sold separately gt DIGITAL INCUBATOR z s 1 Incubation Modes 50 3 Fu nction Setting Incubation start with Automatic Mode Incubation Modes MANUAL button Selection of birds ENTER button Auto incubation starts after two seconds x Rcom Pro 50 incubator has two modes as automatic and manual mode and Rcom USB 50 incubator has three modes as automatic manual and PC connecting mode Auto incubation B Setting of temperature of early and middle stages of incubation Temperature setting 2 Setting of temperature of final stage of incubation 3 Setting of date of temperature change in the final stage of incubation MENU button i Setting of humidity of Rcom PRO 50 OTHER MANUAL incubation UP DOWN button Humidity setting early and middle stages of incubation Room USB 50 Other birds Selection of birds 6 Setting of humidity of final stage of incubation Setting of date of humidity change in th
24. oduct with organic solvents such as benzene thinner etc which may cause deformation or decoloration 22 DIGITAL INCUBATOR 1 Servicing 7 Product Information Frequently Asked Questions FAQ SO Servicing All our Rcom digital incubators of Autoelex Co Ltd are made by precision systems under strict quality control But occasionally some defective products are found on the way of their distribution If any problem occurs then please contact Recom service center or distributorsin your country We will do our best to solve the problems if any for you This product is designed in modular mode so for its repair if any a qualified person can replace the part concerned with ease Complaint Department 82 55 337 2560 Frequently Asked Questions FAQ E mail Receipt Rcom Rcom co kr In case hatching rate is low When a chick hatches out earlier than expected or a deformed chick hatches out When a chick hatches out later than expected When hatching dates are so different from each egg When all chicks don t hatch out at the same time but over a long period When intending to hatching various eggs at the same time DIGITAL INCUBATOR gt When the egg is an unfertilized egg gt Getting infected by germs gt Wrong incubation setting gt Health condition of mother bird gt Improper egg turning gt Setting temperature high gt Egg turning was not operating normally gt Setting tempe
25. ol amp How to Operate Menu Button Up Button Temp amp Humidity UP Setting Value Change Select Birds Incubation Termination Room PRO SO MENU Select Button MANUAL So S Down Button SHIFT ap Select Auto Manual re A 37 5 Temp amp Humidity DOWN Pass to next stage op 90 m ss 45y Setting Value Change Function Button Input Button Other function display Return to previous stage Save input and Pass to next stage Egg Turning Interval Indication ug g Setting Value Check Egg Turning Angle Indication uo What s Temperature amp Humidity Setting This is that you set up temp amp humi As you want to have inside of the machine Choose a kind Chicken Egg Turning Indication i eure Manual Egg Turning Stop x Pheasant 4 Indication Po AY gt Automatic Egg Turning Stop wildgoose 7 Indication Bird Icon Display oo Incubation Termination x Others Birds Chicken Species of Birds FAN Operation Display Current Temperature Display Heater Stop Display Temperature Abnormal Display Heater Operation Display Current Humidity Display Humidification Stop Display S55 ee yp all ORF Humidification function OFF 9 ao Operation Egg Turning Interval Indication Water Supplement Egg Turning Angle Indication Humidity Abnormal a AN Aa Connecting Power Failure Notification lt USB MODEL gt arm DIGITAL INCUBATOR 6 SET UP Other Functions 5 1 Introducti
26. on 15 Easy Enen aan SET U P Other Fu nections gt Push SET UP key and then select SE BOON ENTER T CAL A WARNING Be sure to read CAUTIONS We do no recommend customers Temperature Fatal Damage to recalibrate by their own If you need to recalibrate please Calibration pee ask purchase place H CAL A WARNING Be sure to read CAUTIONS We do no recommend customers Humidity Fatal Damage to recalibrate by their own If you need to recalibrate please Calibration with Incorrect Calibration ask purchase place ALARM i Alarm sounds when incubator temp is higher than setting value Abnomal because of room temp change or heating system disorder High Alarm i Setting Range 0 0 C 5 0 C Default Setting 2 0 C ALARM Alarm sounds when incubator temp is lower than setting value Abnomal because of room temp change or heating system disorder low Alarm Setting Range 0 0 C 5 0 C Default Setting 3 0 Selecting Centigrade C and Fahrenheit F Default Value Centigrade C LCD Backlight management setting Always On Always BackLight On Always Off Always BackLight Off Event On 20 Sec ON with Key input Default Value Always On ON OFF Setting for Melody other alarms Default Value ON Slated ALL RESET It returns to factory setting when you change the initial setting at discretion m Basic information of Incubator versoin Indication X put some water after take off label
27. plication for stable power supply Upgrade to the latest model incubator with program upgrade USB MODEL ONLY Safety Features Self examination function for sensing abnormal conditions Alarm and display function for abnormal incubator temperature caused by sudden fluctuation of ambient temperature Incubation data memory function and power outage notification function in case of power failure Circulation fan cover for safety and electric safety cut out switch on the upper main body for safety Heater supporter designed for heater tension control and its safety Safety cover applied for protecting humidification unit Humidification unit durability improved by water proof BLDC fan Alarm when water need replenishing Easy Features No need of separate humidification unit as it included in main body C or F convertible Various kinds of egg trays accept various sized eggs with ease Slide plate with embossed feature for preventing skid Variable air vent for adjusting air supply Bottom body designed for easy cleaning Roller Dividers which can safely apply egg turning for expensive or rare eggs Option 4 DIGITAL INCUBATOR S5 1 Introduction 2 Safety Precautions Electrical hazards ACAUTION Be careful the details below when you use Do not use a damaged power Do not pull the cord when Never pull the plug out of the Do not twist or crush electric Do not insert multiple cord or loose o
28. rature low gt Eggs stored for different lengths of time gt Diffferent incubation temperatures gt Incubation days are different so hatching rate falls down gt Eggs might be contaminated by chicks that hatched first gt Inspect the egg to check possibility of egg surviving gt Disinfect the incubator gt Check all settings of incubator Especially check them focusing on the temperature gt Review care of health of mother bird gt Check if egg turning is normal gt Lower temp setting of the incubator about 0 5 C 1 F ex 37 5C 99 5 F gt 37 0C 98 6 F gt Check if egg turning function is OFF gt Raise temp setting of the incubator about 0 5 C 1 F gt ex 37 0C 98 6 F gt 37 5C 99 5 F gt Minimize the time to store egg properly gt Check Temperature difference in the incubator sunlight temp of incubation room etc gt Mark hatching date on eggs and move them to other incubator brooder just on the marked date gt In case of putting in many eggs at the same time it s convenient to prepare a spare incubator available as a brooder 7 Product Information Troubleshooting 2 Troubleshooting If you need detail self diagnosis please click self diagnosis on our website CIRCUMSTANCE ITEMS TO BE CONFIRMED SOLUTIONS No signs of power to the incubator Temperature will not go high enough Alarm sounds with HI indication abnormal high temp
29. rfilled the incubator gt Check that the incubator placed on inclined Surface gt Check if it is Dew condensation gt Connect the cord again gt Check the main socket with any other electric appliances gt Try to insert to another outlet gt Set the temperature as required gt Take the power plug out of the outlet and disassemble the main body for cleaning around the air circulation fan with brush gt Adjust room temperature 28 C 82 4 F gt Install incubator without the direct rays of sun gt Return incubator to factory setting Refer to page 17 gt Adjust room temperature 28 C 82 4 F gt Place thermometer inside of incubator and check if setting temperature is correct gt Return incubator to factory setting Refer to page 17 gt Supply water gt Set the humidity again as required gt Take out the plug out of the outlet and disassemble the main body and clean around the air circulation fan with brush gt If you need to turn the eggs you can manually re start egg turning gt Unplug the power supply and disassemble the main body for cleaning the egg turning tray and gear gt Assemble egg turning plate as the picture on page 10 gt Move the incubator to where the ambient air temperature is over 28 C 82 4 F gt Dew condensation is normal gt Dry the incubator completely under well ventilated place gt Do not fill water over LIMIT indication gt Place incubator under
30. rom can be dropped or damaged Or accidental interference with incubation process accidental knocks or drops the controls Do not disassemble or modify Please ensure that no small If the incubator sounds Clean the incubator thoroughly If the incubator requires repair the incubator in any way objects get into strange or emits smoke before storing disconnect from the power gt Risk if electric shock or fire the holes on the incubator contact your service center supply and please contact to gt Risk of electric shock or fire Risk of electric shock or fire your service center a Be sure to disconnect the electric cord Cleaning Cautions AAXCAUTION from the outlet before cleaning Do not spray cleanser directly Clean the incubator by a soft Brush away dust on the plug Do not use chemicals like wax For special cleaning of inner on the incubator surface cloth with a neutral detergent with a dry cloth benzene alcohol thinner part per year contact to the aromatic or lubricant etc service center gt If you don t clean the inside of incubator for a long time dust can cause some trouble or a fire DIGITAL INCUBATOR 5 1 Introduction 3 Identification of Parts and Compositio Identification of Parts Handle For a clear view of the incubation process Double Skin Viewing Window Serial No EX RCM0950278 Power Connecting the rear i Egg Tra Vents for air circulation ee gg Iray l
31. s and then press DOWN button continuously until OFF indication is showing Then press ENTER button to turn humidification off If you want to humidification turn ON set humidity over 30 4Times 5Times Humidification ON Humidification OFF 18 DIGITAL INCUBATOR 1 Egg Turning Check Alarm for water supplement 50 4 Other Functions Abnormal High or Low temperatue Alarm Power Failure Alarm Function Egg Turning Check Function i eat Turning now gt When starting egg turning animation showed on display with melody Water Shortage Detecting Function gt When water is short humidification icon is changed 8 Ed O and water supplement S Woe Op alarm sounds after 5 min This alarm continues Bt S ABs 60 every 30 sec A It takes about 1min to return to normal display after you refill water gt When there is any problem on water detecting Lo S sensor humidification icon is changed like this 385 X and alarm sounds with message gt When incubator temperature is different from l So Sm S setting value icon is changed A gt SP SF GW W395 90 7 IS By lt Example gt When temp difference is 2C it indicates 39 5 and 2 0 alternatively setting 37 5 C Xx Alarm call automatically turned off after 1min but you When temp difference is 3C it indicates 34 5 C and should press ENTER button to switch off alarm indication 3 0 alternatively setting 37 5 C
32. t take any responsibility for Loss of eggs or pet animal lives under any circumstances such as Hatching Brooding failures User s carelessness Personal un certificated conversion alteration Arbitrary using out of the machine s purpose Electric power failure or Malfunctioning Please be sure that the machine works without any problem before placing Eggs or Pets Animals Also we strongly recommend you to read the User s Manual carefully to minimize of any failure Product Information Mark Explanation A N Caution Caution mark against a fault that can cause damage trouble or failure of incubation S Prohibited amp It is necessary to keep Q Do not disassemble Remove the power cord from outlet Do not touch B Ground Connection for preventing electric shock Tip Tip References or useful suggestions in using Rcom product AXCAUTION Warning of actions which may be dangerous or cause damage to the incubator gt For Recom USB 50 MODEL PC connecting refer to the PC SOFTWARE manual DIGITAL INCUBATOR 1 Introduction 1 Rcom 50 Introduction Thank you for choosing the Rcom incubator The Rcom 50 incubator is the first incubator with creditability to have a superior design and function which help in controlling optimum incubation conditions It has two sensors one for detecting surrounding environments and the another for internal incubator conditions The Rcom50 is
33. utlet taking out the power cord and outlet during the incubation cord connecting plugs in an outlet gt Risk of electric shock or fire keep wet hands away from period gt Risk of electric shock or fire Risk of fire or electrical connecting plug gt Incubation will be interrupted overload gt Risk of electric shock or fire Setting Cautions pre Be careful the details below when you use Sy Do not install in dusty or dirty Do not install under the direct Do not install in moist or Do not install in excessively Do not use any other environment sunlight humid environment cold or hot conditions non standard parts except gt Risk of damage or fire within gt Risk of fire or interference gt Risk of fire or electric shock cigarette smoke etc those provided the incubator with the incubation process gt Risk of interference with gt Risk of damage or hatching the incubation process failure Do not cover the ventilating Install away from heat Ensure that the incubator is Do not turn the incubator Children should be supervised opening SOUICES installed on a stable surface upside down to ensure that they do not play gt Inner temperature can rise Risk of damage to the away from edges gt Water will pour out of the with the appliance interrupting incubation incubator case and gt Risk of damage to incubator incubator and view window Risk of knocking the incubator interference with the and eggs and user f
34. ze 370 mm x 270 mm x 130 mm Dew Condensation This is a naturally occurring phenomenon when there is a significant difference in temperature between inside and outside of the incubator during incubation period If this occurs water may form in inside bottom of the main body of the incubator bottom part 20 DIGITAL INCUBATOR 50 6 How to Clean 1 How to Disassemble gt Pull out the electric cord from the connecting jack and also take out the plug from the outlet A Don t turn off the power soon after using the incubator as this may cause a break down due to moisture left inside the main controller At this time it s better to firstly remove the water inside of the incubator and dry by operating it for 1hour and then turn it off or open the view window and dry it naturally for 2 3 hours and then re operate it which may lengthen the life time of incubator Set humidification function OFF Refer to the page 18 How to disassemble and clean the incubator Unlock and remove the locking buttons for four parts at the front and back of incubator by pulling them forward The bottom part of incubator should be thoroughly cleaned with water and dried The upper part should be naturally dried in the well ventilated place for about one day to remove moisture left inside of the incubator after hatching thoroughly A Don t clean the product with organic solvents such as benzene thinner etc which may